• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • Tagged with
  • 30
  • 25
  • 9
  • 9
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Desenvolvimento de método analítico para a determinação simultânea de para-cresol e compostos guanidínicos em plasma de cães / Analytical method development for simultaneous analysis of p-cresol and guanidino compounds in serum of dogs

Diego Borba dos Santos 19 December 2014 (has links)
O para-cresol (4-metilfenol) e as guanidinas são compostos envolvidos em uma série de processos bioquímicos e fisiológicos. Em condições normais esses compostos são eliminados do organismo pelos rins. Entretanto, em pacientes com doença renal crônica (DRC), esses compostos acumulam nos fluidos biológicos e tecidos, e são de difícil remoção, gerando alta taxa de mortalidade em pacientes humanos hemodialisados. Cromatografia gasosa (GC) e cromatografia líquida de alta eficiência (HPLC) são as técnicas analíticas mais utilizadas para a separação e quantificação de p-cresol e guanidinas. A derivatização pré ou pós-coluna geralmente é empregada para aumentar a volatilidade, absorbância ou fluorescência desses compostos, permitindo a detecção e quantificação. A ninidrina é um dos reagentes mais utilizados para a derivatização das guandinas pois apresenta alta sensibilidade, solubilidade em água e o procedimento aplicado para a derivatização é simples, permitindo a automação do sistema de preparo de amostras quando necessário. Embora haja vários estudos sobre a concentração e os efeitos desses compostos no sangue de pacientes humanos com DRC, a concentração de p-cresol e das guanidinas no sangue de cães com DRC e os efeitos associados a tais compostos foram pouco estudados. Assim, são necessários estudos similares aos realizados em humanos, para o desenvolvimento de novas estratégias de tratamento veterinário para cães. Para isso, é importante o desenvolvimento de uma metodologia analítica para a quantificação desses compostos no sangue de cães. Nesse trabalho desenvolveu-se, validou-se e aplicou-se um método para análise de p-cresol e guanidinas em plasma de cães urêmicos com detecção por fluorescência. A reação de derivatização das guanidinas com a ninidrina foi revisada, caracterizada por espectrometria de massas (MS) e otimizada utilizando planejamento fatorial. Foi analisado um total de 63 amostras de plasma de cães incluindo grupo controle e urêmico. A concentração média de guanidina, metilguanidina e p-cresol livre determinada foi maior no grupo urêmico do que no grupo controle, a exemplo do que ocorre em humanos, sugerindo um comportamento metabólico similar desses compostos em cães. O método desenvolvido possibilitou as análises, sendo relativamente simples, evitando um preparo de amostras complexo. Por sua vez, a otimização por planejamento fatorial da reação de derivatizacão com ninidrina resultou em ganhos na área dos picos cromatográficos que chegaram a 1000%. / Para-cresol (4-methylphenol) and guanidino compounds are involved in a series of biochemical and physiological cycles. Under ordinary conditions, these compounds are excreted from the body by healthy kidneys. However, in uremic patients, the concentration of these compounds is highly increased in biological fluids and tissues and is of hard removal, increasing the mortality rate in dialysis patients. Gas chromatography (GC) and high performance liquid chromatography (HPLC) are the most used techniques for separation and quantification of p-cresol and guanidino compounds. For the guanidines determination, derivatizing reactions are usually employed to enhance the absorbance, fluorescence or volatility of these compounds, allowing the quantification. Ninhydrin is one of the most used reagents for derivatization because it shows high sensitivity and presents water solubility. The procedure employed for the derivatization reaction is simple, allowing the automation of sample preparation system, when it is required. There are few studies quantifying the concentration of guanidino compounds and p-cresol in blood of uremic dogs, therefore, a better understanding of the role of these compounds in the metabolism of dogs are needed. For this reason, it is important to develop an analytical method for the quantification of these compounds in dog\'s blood. The development of a method for simultaneous determination of these compounds, which is not reported in the literature, can improve the analytical productivity, decreasing the time spent with sample preparation and analysis. Here, a method based in reversed-phase HPLC for simultaneous quantification of guanidino compounds and free p-cresol in plasma of uremic dogs with fluorescence detection was developed, validated and applied. For this purpose, the ninhydrin derivatization reaction was reviewed, characterized by mass spectrometry (MS) and optimized using central composite design (CCD). A total of 63 samples of dog plasma, including healthy and uremic groups, were analyzed. The mean concentration of guanidine, methylguanidine and free p-cresol determined by the validated method, for the uremic group, were higher than the healthy group, alike usual for humans, suggesting a similar metabolic behavior of these compounds in dogs. The obtained method is relatively simple avoiding complex sample preparation and the experimentally designed optimization of the ninhydrin reaction by CCD yielded a gain of area as high as 1000% for the chromatographic peaks.
22

Derivatização eletroquímica da álcoois num sistema em fluxo para determinação quantitativa por eletroforese capilar com detecção condutométrica sem contato / Electrochemical derivatization of alcohols in a flow system for quantitative determinations by capillary electrophoresis and contactless conductivity detection

Santos, Mauro Sergio Ferreira 29 October 2012 (has links)
A eletroforese capilar (CE) é uma técnica poderosa de separação que explora as diferenças na mobilidade de espécies iônicas sob efeito do campo elétrico. Não permite, contudo, separação de misturas de moléculas neutras, possível mediante formação de complexos com carga, derivatização química ou cromatografia eletrocinética micelar (MEKC). A derivatização eletroquímica tem sido usada em combinação com HPLC, entre outras técnicas, mas não ainda com CE e para fins quantitativos, como proposto e demonstrado nesta dissertação, em que se enfoca, como sistemas modelo, álcoois primários de cadeia curta e se recorre a sistema em fluxo designado de EC-CE-C4D, que consiste de uma célula eletroquímica acoplada com equipamento de eletroforese capilar provido de detector de condutividade sem contato direto com os eletrodos. O sistema EC-CE-C4D, inicialmente concebido para efetuar pré-concentração e redissolução eletroquímica de metais seguida de separação eletroforética, possibilitou também o monitoramento de produtos com carga, formados em processos eletrocatalíticos, fato que inspirou a investigação da aplicabilidade, também do sistema à derivatização eletroquímica de analitos neutros em iônicos ou ionizáveis. Inicialmente, a oxidação de etanol foi avaliada por voltametria cíclica em eletrodos de ouro, paládio e platina policristalinos, nos meios ácido, neutro e alcalino. Maior formação de ácido acético se deu sobre platina em meio ácido (pH = 2,3). Entre os tampões avaliados por simulação (PeakMaster 5.1) para a separação dos carboxilatos, o TRIS/HCl (pH = 8,6) foi favorável em termos de resolução, rapidez e sensibilidade. Após a eletrooxidação da amostra sobre Pt a 1,6 V vs. Ag/AgCl por 60 s seguida de transferência de nanolitros dos produtos formados para o capilar por injeção hidrodinâmica, o meio ácido é trocado pelo tampão de corrida com auxílio de microbombas controladas por computador. A eficiência da conversão eletroquímica dos álcoois em carboxilatos, de 16% para etanol e propanol nas condições adotadas, apesar de não muito eficiente, proporcionou boa repetibilidade e limites de quantificação ao redor de 5 10-5 mol L-1 para etanol, 1-propanol, 1-butanol e 1-pentanol, ou seja, cerca de 20 vezes melhores que os reportados para MEKC. As curvas analíticas para os 4 álcoois apresentaram boa linearidade (R > 0,996) e a boa separação entre os picos permitindo determinações quantitativas simultâneas. Como exemplo de aplicação a amostras reais, demonstrou-se a determinação quantitativa de etanol em cerveja Pilsen convencional (teor alcoólico 4,5% vol.) e sem álcool (teor alcoólico <0,5% vol.), diluídas de 1000 vezes e 100 vezes, respectivamente. A repetibilidade das análises foi muito boa (~6% DPR, n = 40), indicando a estabilidade do sistema automático e ausência de envenenamento da superfície do eletrodo. Resultados ainda melhores foram obtidos utilizando 1-propanol como padrão interno para a determinação de etanol. Comparação dos resultados da dosagem alcoólica obtida com o sistema EC-CE-C4D e por CG-FID não apresentou diferença significativa utilizando um intervalo de confiança de 95 %, demonstrando a efetividade e concordância da nova combinação de técnicas. Este trabalho pioneiro, aliando derivatização eletroquímica com a eletroforese para a quantificação de espécies neutras, abre perspectivas de pesquisa não só para aprofundamento e otimização da análise de álcoois, como para a derivatização de outras espécies neutras na faixa de pH comum em CE, como aldeídos e açúcares. / Capillary electrophoresis (CE) is a powerful separation technique which exploits the differences in the mobility of ionic species under the effect of electric field. However, it does not allow the separation of mixtures of neutral molecules, and alternatives like formation of charged complexes, chemical derivatization and micellar electrokinetic chromatography (MEKC) have been proposed. Electrochemical derivatization has been combined before with HPLC, among other techniques, but not yet with CE and for quantitative purposes, as proposed and demonstrated in this Masters Thesis, focusing as model systems, short chain primary alcohols, using a flow system, designated EC-EC-C4D, composed of an electrochemical cell coupled with a capillary electrophoresis equipment provided with conductivity detector without direct contact with the electrodes. The EC-CE-C4D system, originally proposed to perform electrochemical pre-concentration and stripping of metals followed by electrophoretic separation, also enabled the monitoring of charged products formed in electrocatalytic processes, inspiring the application of the system to electrochemical derivatization of uncharged analytes into ionic or ionizable ones. Initially, the ethanol oxidation was evaluated by cyclic voltammetry on gold, palladium and platinum polycrystalline electrodes, in acid, neutral and alkaline medium. Larger formation of acetic acid was observed on platinum in acid medium (pH = 2.3). Among the buffers evaluated by simulation (PeakMaster 5.1) for separation of carboxylates, aiming to compromise between resolution, speed and sensitivity, TRIS / HCl (pH 8.6) was favorable. After the sample electrooxidation on Pt at 1.6 V vs. Ag/AgCl for 60 s is replaced automatically (by computer controlled micropumps) by running buffer, followed by the hydrodynamic injection into the capillary of products formed, the acid medium is replaced by running buffer with help of computer controlled micropumps. The efficiency of the electrochemical conversion of alcohols into carboxylates, 16% for ethanol and propanol at the given conditions, although not very efficient, but showed good repeatability and rendered quantification limits around 5 10-5 mol L-1 for ethanol, 1-propanol, 1-butanol and 1-pentanol the 4 alcohols, about 20 times better for MEKC. The analytical curves for the four alcohols, showed good linearity (r > 0.996) and the separation between peaks allowed simultaneous quantitative determinations. As an example of application to real samples, the quantitative determination of ethanol in Pilsen conventional beer (alcohol content 4.5% vol.) and non-alcoholic beer (alcohol content <0.5% vol.) was carried out after 1000-fold and 100 fold dilution, respectively. The repeatability of the analysis was very good (~6% RSD, n = 40), indicating the stability of the system and no poisoning of the electrode. Even better results were obtained using 1-propanol as an internal standard for the determination of ethanol. Comparison of results obtained with the CE-CE-C4D system and by GC-FID showed no significant difference for a confidence interval of 95%, demonstrating the effectiveness and consistency of the new combination of techniques. This proof of concept work of the combination of electrochemical derivatization with electrophoresis for quantification of neutral species opens perspectives not only for the optimization of the analysis of alcohols, but for research on the derivatization of other neutral species in the pH range typical for CE, like aldehydes and sugars.
23

Extração em ponto nuvem com derivatização do surfactante: uma alternativa para a determinação de hidrocarbonetos policíclicos aromáticos em águas naturais por cromatografia gasosa

Rocha, Sarah Adriana do Nascimento 10 1900 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2014-09-19T18:04:41Z No. of bitstreams: 1 Tese_Sarah_Rocha_LSGT.pdf: 3229640 bytes, checksum: af1acce9c5d43271ea20530b0fd1f510 (MD5) / Approved for entry into archive by Fatima Cleômenis Botelho Maria (botelho@ufba.br) on 2014-09-22T12:43:20Z (GMT) No. of bitstreams: 1 Tese_Sarah_Rocha_LSGT.pdf: 3229640 bytes, checksum: af1acce9c5d43271ea20530b0fd1f510 (MD5) / Made available in DSpace on 2014-09-22T12:43:20Z (GMT). No. of bitstreams: 1 Tese_Sarah_Rocha_LSGT.pdf: 3229640 bytes, checksum: af1acce9c5d43271ea20530b0fd1f510 (MD5) / Um método de extração em ponto nuvem de hidrocarbonetos policíclicos aromáticos foi desenvolvido, utilizando tensoativos octilfenol polietoxilados com derivatização do coacervato, como etapa que antecede a detecção por cromatografia a gás acoplada à espectrometria de massa. Foi realizado um estudo da influência da presença de aditivos na redução da temperatura de ponto nuvem do OPEO30 e do OPEO35, surfactantes com temperaturas de ponto nuvem superiores a 100 oC, através adição de sais, álcoois, OPEO7.5 e misturas de sais e álcoois. Observou-se em todos os casos diminuição da temperatura, sendo o sulfato de sódio o aditivo que resultou maior redução da temperatura. Selecionou-se o OPEO30 para as demais etapas do trabalho. Fez-se a otimização das condições da reação de derivatização do coacervato por meio de planejamento fatorial 23, utilizando-se a resposta global para avaliar os resultados. Selecionou-se as condições do ponto central do planejamento fatorial, ou seja, 125 L de BSTFA, 100 L de piridina e banho de água à 70 oC por 45 min, para a derivatização de 30 L de fase rica em surfactante. O procedimento de ponto nuvem foi otimizado, sendo avaliadas as variáveis concentração de surfactante, temperatura e tempo de banho de água, sendo proposta a seguinte metodologia: 1,0 mL de OPEO30 10% m v-1, 10,0 mL de amostra, 1,25 g de sulfato de sódio anidro, banho de água à 70 oC por 10 min, centrifugação à 3000 rpm por cinco min. O método mostrou-se seletivo, sendo observado efeito de matriz intenso, o qual foi corrigido. Os limites de quantificação obtidos estão entre 39 e 176 ng L-1. O método proposto também foi comparado com o método USEPA 3510C, estando as concentrações obtidas, quando analisada uma amostra real de água subterrânea, bem próximas, com recuperações variando entre 90,0 e 97,5 %. O método proposto foi aplicado a amostras de água subterrânea coletadas em poços localizados em postos de revenda de combustíveis. Em todas as amostras foram detectados HPA. / A method for cloud point extraction of polycyclic aromatic hydrocarbons was developed using surfactants octylphenol polyethoxylated with the coacervate derivatization as step prior to gas chromatography-mass spectrometry detection. An influence of additives study on the reduction of cloud point temperature OPEO30 and OPEO35, surfactants with cloud point temperatures above 100 ° C, was conducted, by addition of salts, alcohols, and mixtures OPEO7.5 salts and alcohols. It was observed in all cases cloud point reduction and sodium sulfate was the additive that result in a most effective. The OPEO30 was selected for others work steps. The factorial design 23 was used to optimize the reaction of derivatization, using the global response to evaluate the results. Were selected the central point experimental design condition, 125 L of BSTFA, 100 L of pyridine and water bath at 70 oC for 45 min for 30 L of surfactant-rich phase derivatization. The cloud point extraction procedure was optimized and surfactant concentration, heating bath temperature and time variables, were evaluated. Was proposed the following method: 1,0 mL of OPEO30 10% v m-1 solution, 10,0 mL of sample, 1,25 g of anhydrous sodium sulfate, water bath at 70 °C for 10 min. The centrifugation was performed at 3000 rpm for five min, removing the aqueous layer after each centrifugation step. A 30L coacervate aliquot was withdrawn, and performed derivatization and subsequent GC-MS analysis. The method was validated. The method was selective, an intense matrix effect was observed and was corrected. The quantification limits obtained were between 39 and 176 ng L-1.
24

Derivatização eletroquímica da álcoois num sistema em fluxo para determinação quantitativa por eletroforese capilar com detecção condutométrica sem contato / Electrochemical derivatization of alcohols in a flow system for quantitative determinations by capillary electrophoresis and contactless conductivity detection

Mauro Sergio Ferreira Santos 29 October 2012 (has links)
A eletroforese capilar (CE) é uma técnica poderosa de separação que explora as diferenças na mobilidade de espécies iônicas sob efeito do campo elétrico. Não permite, contudo, separação de misturas de moléculas neutras, possível mediante formação de complexos com carga, derivatização química ou cromatografia eletrocinética micelar (MEKC). A derivatização eletroquímica tem sido usada em combinação com HPLC, entre outras técnicas, mas não ainda com CE e para fins quantitativos, como proposto e demonstrado nesta dissertação, em que se enfoca, como sistemas modelo, álcoois primários de cadeia curta e se recorre a sistema em fluxo designado de EC-CE-C4D, que consiste de uma célula eletroquímica acoplada com equipamento de eletroforese capilar provido de detector de condutividade sem contato direto com os eletrodos. O sistema EC-CE-C4D, inicialmente concebido para efetuar pré-concentração e redissolução eletroquímica de metais seguida de separação eletroforética, possibilitou também o monitoramento de produtos com carga, formados em processos eletrocatalíticos, fato que inspirou a investigação da aplicabilidade, também do sistema à derivatização eletroquímica de analitos neutros em iônicos ou ionizáveis. Inicialmente, a oxidação de etanol foi avaliada por voltametria cíclica em eletrodos de ouro, paládio e platina policristalinos, nos meios ácido, neutro e alcalino. Maior formação de ácido acético se deu sobre platina em meio ácido (pH = 2,3). Entre os tampões avaliados por simulação (PeakMaster 5.1) para a separação dos carboxilatos, o TRIS/HCl (pH = 8,6) foi favorável em termos de resolução, rapidez e sensibilidade. Após a eletrooxidação da amostra sobre Pt a 1,6 V vs. Ag/AgCl por 60 s seguida de transferência de nanolitros dos produtos formados para o capilar por injeção hidrodinâmica, o meio ácido é trocado pelo tampão de corrida com auxílio de microbombas controladas por computador. A eficiência da conversão eletroquímica dos álcoois em carboxilatos, de 16% para etanol e propanol nas condições adotadas, apesar de não muito eficiente, proporcionou boa repetibilidade e limites de quantificação ao redor de 5 10-5 mol L-1 para etanol, 1-propanol, 1-butanol e 1-pentanol, ou seja, cerca de 20 vezes melhores que os reportados para MEKC. As curvas analíticas para os 4 álcoois apresentaram boa linearidade (R > 0,996) e a boa separação entre os picos permitindo determinações quantitativas simultâneas. Como exemplo de aplicação a amostras reais, demonstrou-se a determinação quantitativa de etanol em cerveja Pilsen convencional (teor alcoólico 4,5% vol.) e sem álcool (teor alcoólico <0,5% vol.), diluídas de 1000 vezes e 100 vezes, respectivamente. A repetibilidade das análises foi muito boa (~6% DPR, n = 40), indicando a estabilidade do sistema automático e ausência de envenenamento da superfície do eletrodo. Resultados ainda melhores foram obtidos utilizando 1-propanol como padrão interno para a determinação de etanol. Comparação dos resultados da dosagem alcoólica obtida com o sistema EC-CE-C4D e por CG-FID não apresentou diferença significativa utilizando um intervalo de confiança de 95 %, demonstrando a efetividade e concordância da nova combinação de técnicas. Este trabalho pioneiro, aliando derivatização eletroquímica com a eletroforese para a quantificação de espécies neutras, abre perspectivas de pesquisa não só para aprofundamento e otimização da análise de álcoois, como para a derivatização de outras espécies neutras na faixa de pH comum em CE, como aldeídos e açúcares. / Capillary electrophoresis (CE) is a powerful separation technique which exploits the differences in the mobility of ionic species under the effect of electric field. However, it does not allow the separation of mixtures of neutral molecules, and alternatives like formation of charged complexes, chemical derivatization and micellar electrokinetic chromatography (MEKC) have been proposed. Electrochemical derivatization has been combined before with HPLC, among other techniques, but not yet with CE and for quantitative purposes, as proposed and demonstrated in this Masters Thesis, focusing as model systems, short chain primary alcohols, using a flow system, designated EC-EC-C4D, composed of an electrochemical cell coupled with a capillary electrophoresis equipment provided with conductivity detector without direct contact with the electrodes. The EC-CE-C4D system, originally proposed to perform electrochemical pre-concentration and stripping of metals followed by electrophoretic separation, also enabled the monitoring of charged products formed in electrocatalytic processes, inspiring the application of the system to electrochemical derivatization of uncharged analytes into ionic or ionizable ones. Initially, the ethanol oxidation was evaluated by cyclic voltammetry on gold, palladium and platinum polycrystalline electrodes, in acid, neutral and alkaline medium. Larger formation of acetic acid was observed on platinum in acid medium (pH = 2.3). Among the buffers evaluated by simulation (PeakMaster 5.1) for separation of carboxylates, aiming to compromise between resolution, speed and sensitivity, TRIS / HCl (pH 8.6) was favorable. After the sample electrooxidation on Pt at 1.6 V vs. Ag/AgCl for 60 s is replaced automatically (by computer controlled micropumps) by running buffer, followed by the hydrodynamic injection into the capillary of products formed, the acid medium is replaced by running buffer with help of computer controlled micropumps. The efficiency of the electrochemical conversion of alcohols into carboxylates, 16% for ethanol and propanol at the given conditions, although not very efficient, but showed good repeatability and rendered quantification limits around 5 10-5 mol L-1 for ethanol, 1-propanol, 1-butanol and 1-pentanol the 4 alcohols, about 20 times better for MEKC. The analytical curves for the four alcohols, showed good linearity (r > 0.996) and the separation between peaks allowed simultaneous quantitative determinations. As an example of application to real samples, the quantitative determination of ethanol in Pilsen conventional beer (alcohol content 4.5% vol.) and non-alcoholic beer (alcohol content <0.5% vol.) was carried out after 1000-fold and 100 fold dilution, respectively. The repeatability of the analysis was very good (~6% RSD, n = 40), indicating the stability of the system and no poisoning of the electrode. Even better results were obtained using 1-propanol as an internal standard for the determination of ethanol. Comparison of results obtained with the CE-CE-C4D system and by GC-FID showed no significant difference for a confidence interval of 95%, demonstrating the effectiveness and consistency of the new combination of techniques. This proof of concept work of the combination of electrochemical derivatization with electrophoresis for quantification of neutral species opens perspectives not only for the optimization of the analysis of alcohols, but for research on the derivatization of other neutral species in the pH range typical for CE, like aldehydes and sugars.
25

Teor de apramicina: desenvolvimento e validação de método empregando cromatografia líquida de alta eficiência comparativamente a um doseamento microbiológico / Apramycin determination: development and validation of method employing high performance liquid chromatography in comparison to a microbiological assay

Elisabete de Almeida Barbosa 03 August 2009 (has links)
A apramicina é um antibiótico aminoglicosídeo produzido por uma cepa de Streptomyces Tenebrarius, utilizada na medicina veterinária na forma de sulfato para tratar e prevenir doenças infecciosas produzidas por bactérias gram-negativas em porcos, bezerros e aves domésticas. As preparações comercialmente disponíveis são injetável, premix para adição em rações e pó oral solúvel, sendo esta última objeto de estudo deste trabalho. A Farmacopéia Britânica é o único compêndio oficial que descreve a apramicina (tanto a matéria-prima quanto as preparações) e recomenda o método microbiológico turbidimétrico para o seu doseamento. Embora os métodos microbiológicos ainda sejam os métodos de escolha na determinação da potência de antibióticos, há uma tendência crescente em substituí-los pelos métodos físico-químicos, sobretudo a cromatografia líquida de alta eficiência (CLAE), a qual proporciona sensibilidade, especificidade, exatidão e precisão; ela já vem sendo usada com sucesso na determinação do teor de antibióticos, embora a sua potência possa estar sujeita a confirmação por um método microbiológico. Considerando-se as vantagens da CLAE, bem como a inexistência de métodos físico-químicos oficiais para a análise de apramicina, o objetivo do presente trabalho foi desenvolver e validar um método empregando a cromatografia líquida de alta eficiência para a quantificação de apramicina em pó oral solúvel, bem como correlacioná-lo com o método turbidimétrico. Foi desenvolvido um método por CLAE empregando fase reversa com o uso de uma coluna C18 de 150 mm x 4,6 mm x 4 &#181;m, derivatização pré-coluna com o-ftalaldeído (OPA) e detecção por UV em 332 nm. A metodologia proposta foi validada de acordo com normas dos compêndios oficiais e apresentou: boa robustez; linearidade no intervalo de 0,02 a 0,05 mg/mL com obtenção de uma curva de calibração de equação igual a y = 132887304,980x + 127223,837 e coeficiente de correlação linear de 0,9999; boa precisão, sendo o DPR<1,0% para a precisão intra-dia e DPR = 1,1% para a precisão inter-dia; 99,33% de recuperação média, demonstrando exatidão; sensibilidade, com limites de detecção e de quantificação de 0,08 e 0,25 &#181;g/mL, respectivamente. Três lotes de apramicina pó oral solúvel foram analisados pelo método por CLAE e pelo método microbiológico oficial e a comparação estatística entre os resultados obtidos através do Teste T demonstrou que não houve diferença significativa entre ambos no nível de &#945; = 0,05. / Apramycin is an aminoglycoside antibiotic produced by Streptomyces tenebrarius strain, widely used in veterinary medicine under sulfate form to treat and prevent infectious diseases induced by gram-negative bacteria in swines, calves and poultry. The commercially available preparations consist of injections, additive feed (premix) and soluble oral powder, being the latter the aim of this work. British Pharmacopoeia is the only official compendium that describes apramycin (bulk pharmaceutical and its formulations) recommending the microbiological turbidimetric method for its dosage. Although microbiological methods are still of chosen for the determination of antibiotics potency, there is an increasing tendency of replacing them by physico-chemical methods, mainly high performance liquid chromatography (HPLC), which offers sensitivity, specificity, accuracy, and precision; it has been successfully used in the determination of antibiotic assay, although its potency may be subjected to confirmation by a microbiological method. Taking into account the advantages of HPLC as well as the absence of official physicochemical methods to analyze apramycin, the aim of the present work was to develop and validate a method employing high performance liquid chromatography to the quantification of soluble oral powder, as well as to compare it with the turbidimetric method. A HPLC method was developed employing reverse phase with a C18 column of 150 mm x 4,6 mm x 4 &#181;m, pre-column derivatization with OPA (o-phthalaldehyde) and UV detection at 332 nm. The proposed method was validated according to official compendia guidelines, having demonstrated: good robustness; linearity in the concentration range of 0,02 to 0,05 mg/mL with linear equation of y = 132887304,980x + 127223,837 and correlation coeficient of 0,999; good precision, being RSD<1,0% for intra-day precision and = 1,1% for inter-day precision; average recuperation of 99,33%, what demonstrates accuracy; sensitivity, with quantification and detection limits of 0,08 and 0,25 &#181;L/mL, respectively. Three batches of apramycin soluble oral powder were analyzed by HPLC method and by the official microbiological method having the statistical comparison between the obtained results by T test demonstrated that there are no significant differences between both of them at &#945; = 0,05 level.
26

DETERMINAÇÃO POR CROMOTOGRAFIA EM FASE GASOSA DE AMINOÁCIDOS LIVRES EM SALAMES SUBMETIDOS A ULTRASSOM / AMINO ACIDS DETERMINATION BY GAS CHROMATOGRAPHY IN SALAMI SUBJECTED TO ULTRASOUND PROCEDURE

Donadel, Jossiê Zamperetti 12 March 2015 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Amino acids are organic compounds abundant in animal tissues, especially in meat and meat products, in free form or polymers, participating in biochemical reactions and may be precursors of compounds of interest in the quality control of these foods. The aim of this study was to optimize and validate a method for determination of free amino acids by gas chromatography in Italian dry fermented sausage subjected to ultrasonic bath for 3, 6 and 9 min. Free amino acids were evaluated in salami pieces fermented/seasoned (initial time), at finished product (28 days) and 120 days after manufacture. The extraction was performed using 0.1 N HCl. An aliquot of samples were subjected to vacuum drying, followed by derivatization with MTBSTFA, which has been optimized with respect to time, temperature and reaction solvents (pyridine and acetonitrile). The instrumental and chromatographic conditions of injector temperature, constant pressure and column temperature program was optimized to ensure the method selectivity and efficiency. The use of a mixture of acetonitrile/MTBSTFA in the ratio 1:1 (v/v) using a temperature of 100 °C for 2 h promoted derivatizing all L-amino acids contained in the analytical standards.The injector temperature of 320 °C and 15 psi constant pressure gave the best efficiency in mass transfer of the analytes into the column, while also providing higher resolution and accuracy. The determination coefficients obtained for amino acids were higher than 0.99, except for glycine (0.98). Fourteen amino acids showed a linear range of from 1.0 to 160.0 mg L-1 with LOD and LOQ ranged between 0.3 and 10 g ml-1 and 1 and 20 mg L-1 and inter-day coefficients of variation accurately less than 15% for most analytes.The increase in the concentrations of most amino acids was observed over time processing/storage, indicating that there was an intense proteolytic activity with the release of free amino acids. In the finished product (28 days), treatment with ultrasound affected significantly (p <0.05) concentration of some amino acids. At this point, the amino acids alanine, glycine, valine, leucine, proline and methionine (non-polar) and tyrosine (polar uncharged) showed lower concentrations to control, on the other hand there was an increase of glutamic acid and arginine. The free amino acids found in salami are important compounds because through chemical reactions of decarboxylation or deamination can be precursors of volatile compounds responsible for characteristic processed meat product flavor/aroma. Thus, the employment of no conventional analytical techniques such as gas chromatography for determination of free amino acids allows obtaining information of great importance for the quality control and product development, correlating the technological and nutritional properties with the properties sensory involving amino acids as precursors. / Os aminoácidos são compostos orgânicos abundantes em tecidos animais, sobretudo em carne e produtos cárneos, na forma livre ou de polímeros, participando de reações bioquímicas, podendo ser precursores de compostos de interesse no controle de qualidade destes alimentos. O objetivo do presente trabalho foi otimizar e validar um método para determinação de aminoácidos livres por cromatografia em fase gasosa em salame tipo Italiano submetido a banho ultrassônico por 3, 6 e 9 min. Os aminoácidos livres foram avaliados na massa de salame não fermentada/maturada (tempo inicial), no produto acabado (28 dias) e após 120 dias da fabricação. A extração dos analitos foi realizada com a utilização de HCl 0,1 N. Uma alíquota das amostras foram submetidas à secagem a vácuo seguida de derivatização com MTBSTFA, a qual foi otimizada em relação ao tempo, temperatura e solventes de reação (piridina e acetonitrila). As condições instrumentais e cromatográficas de temperatura do injetor, pressão constante e programação de temperatura da coluna foram otimizadas para garantir a seletividade e eficiência do método. O emprego da mistura de acetonitrila/MTBSTFA na proporção de 1:1 (v/v), utilizando a temperatura de 100 °C por 2 h promoveu a derivatização de todos os L- aminoácidos contidos nos padrões analíticos. A temperatura do injetor a 320 °C e pressão constante de 15 psi proporcionou a melhor na eficiência na transferência de massa dos analitos para coluna, proporcionando também maior resolução e precisão. Os coeficientes de determinação obtidos para os aminoácidos foram maiores que 0,99, com exceção da glicina (0,98). Quatorze aminoácidos apresentaram faixa linear entre 1,0 160,0 μg mL-1, com LOD e LOQ variando entre 0,3 e 10 μg mL-1 e 1 e 20 μg mL-1 e precisão intra-dia com coeficientes de variação menores que 15% para a maioria dos analitos. O aumento nas concentrações da maioria dos aminoácidos foi observado com decorrer do tempo do processamento/armazenamento, indicando que houve uma intensa atividade proteolítica com liberação de aminoácidos livres. No produto pronto (28 dias), os tratamentos com ultrassom afetaram significativa (p<0,05) a concentração de alguns aminoácidos. Nesse ponto, os aminoácidos alanina, glicina, valina, leucina, prolina e metionina (apolares) e tirosina (polar sem carga) apresentaram concentrações inferiores ao controle, por outro lado foi observado um aumento dos de ácido glutâmico e arginina. Os aminoácidos livres encontrados nas amostras de salame são compostos importantes, pois através de reações químicas de descarboxilação ou desaminação podem ser precursores de compostos voláteis responsáveis pelo sabor/aroma característicos do produto cárneo processado. Dessa forma, o emprego de técnicas analíticas não convencionais, como a cromatografia em fase gasosa, para a determinação de aminoácidos livres, permite a obtenção de informações de grande importância no controle de qualidade e desenvolvimento de produtos, correlacionando as propriedades tecnológicas e nutricionais com as propriedades sensoriais que envolvem os aminoácidos como precursores.
27

Eletroforese capilar com derivatização eletroquímica de compostos neutros: novas aplicações, otimização e miniaturização do sistema em fluxo EC-CE-C4D / Capillary Electrophoresis with Electrochemical Derivatization of Neutral Compounds: New Application, Optimization and Miniaturization of the Flow System EC-CE-C4D

Santos, Mauro Sergio Ferreira 12 December 2016 (has links)
A combinação de célula eletroquímica (EC) com a entrada do equipamento de eletroforese capilar (CE), apesar de recente, tem permitido realizar determinação de ânions radicais; pré-concentração eletroquímica de metais pesados, seguida de redissolução, separação e detecção; bem como monitorar produtos carregados formados por oxidação eletrocatalítica de espécies neutras, como álcoois primários e glicerol. Empregando o sistema EC-CE-C4D desenvolvido pelo grupo, a determinação simultânea de cátions, ânions (no contra fluxo) e espécies neutras (detectadas após derivatização eletroquímica) foi demonstrada pela primeira vez, tendo o antisséptico bucal (Listerine® Tartar Control) como amostra real. Embora constante e reprodutível, a conversão dos álcoois primários nos respectivos carboxilatos apresentou rendimento relativamente baixo, ~16%, nas condições anteriormente adotadas, 1,6 V vs. Ag/AgClKCl 3M empregando eletrodo de platina em meio ácido (HNO3 5 mmol L-1 / HCl 1 mmol L-1). Dessa maneira, avaliou-se a oxidação de álcoois primários de cadeia normal (C2 &#8722; C5) sobre diferentes materiais de eletrodo (ouro e platina) em diferentes meios (ácido, neutro e alcalino). Os carboxilatos gerados foram monitorados injetando uma alíquota da amostra derivatizada no capilar (50 &#181;m d.i., 45 cm de comprimento e 20 cm efetivo) aplicando 5 kPa durante 5 s, e durante as separações, 30 kV foi aplicado entre as extremidades do capilar preenchido com Tris 30 mmol L-1 / HCl 10 mmol L-1 usado como BGE. Os resultados obtidos com o sistema EC-CE-C4D apontaram maior conversão dos álcoois nos respectivos ácidos carboxílicos em meio ácido, tanto em ouro quanto em platina. Adicionalmente, em eletrodo de ouro a formação dos carboxilatos apresentou certa seletividade não observada sobre platina, favorecendo a conversão dos álcoois de cadeia menor. Noutra vertente, buscando atender as necessidades atuais por metodologias que possibilitem monitorar a eletrooxidação do glicerol em reatores eletroquímicos, desenvolveu-se um método que permitiu determinar simultaneamente o glicerol e alguns de seus possíveis produtos de oxidação neutros, como gliceraldeído e dihidroxiacetona, explorando a formação de complexo carregado com borato (presente no BGE composto por H3BO3 60 mmol L-1 / LiOH 30 mmol L-1), além dos produtos ionizáveis (ácidos carboxílicos) que são comumente analisados por CE. O equipamento de CE utilizado, munido de dois detectores C4D, também permitiu avaliar a interação de alguns ácidos carboxílicos com os modificadores de EOF, Polybrene® e CTAB, empregando MES 30 mmol L-1 / His 30 mmol L-1 como BGE. Seguindo a atual tendência à miniaturização de sistemas analíticos, avaliou-se a possibilidade de construir um sistema EC-CE-C4D miniaturizado. Para isso, um novo método para fabricação de microdispositivos em vidro, baseado em ablação a laser de CO2 assistida por parafina, como alternativa aos dispendiosos métodos de corrosão por via úmida foi desenvolvido. Os dispositivos obtidos por esse método apresentaram canais de perfil semicircular, e as dimensões puderam ser controladas variando a potência e/ou a velocidade de ablação do laser. Contudo, pelos desafios ainda encontrados para se construir um sistema EC-CE-C4D completo em substrato de vidro por ablação a laser de CO2, optou-se por iniciar a miniaturização do sistema EC-CE-C4D com um sistema híbrido em que se aproveita as características mais bem definidas e favoráveis dos tubos capilares de sílica fundida usados em CE convencional. Esse sistema permitiu a determinação quantitativa de metanol na presença de alta concentração de etanol, possibilitando, numa primeira aplicação, realizar o monitoramento da quantidade de metanol e etanol nas frações iniciais coletada durante o processo de destilação fracionada na produção de uísque de milho (moonshine) feito em laboratório. Visto a maior seletividade para conversão dos álcoois de cadeia menor obtidas em eletrodo de ouro e meio ácido, esse foi escolhido para a presente aplicação. As condições que apresentaram melhores resultados no sistema híbrido EC-CE-C4D abrangeram diluição de 100 vezes da amostra em HNO3 2 mmol L-1, eletrooxidação a 1,4 V vs. Ag durante 60 s, injeção eletrocinética no capilar mediante aplicação de 3 kV durante 4 s, e a separação dos carboxilatos realizada aplicando 3 kV entre as extremidades do capilar (50 &#181;m d.i., 15 cm de comprimento com 12 cm efetivo), preenchido com CHES 10 mmol L-1 / NaOH 5 mmol L-1, usado como BGE. A análise das primeiras frações destiladas da \"labmade moonshine\" apresentou um aumento na concentração de etanol (variando de ~80 % a ~100 %) e simultâneo decréscimo da concentração de metanol (variando de 4 % a ~0,1 %). Em suma, avançou-se tanto no leque de aplicações da derivatização eletroquímica hifenizada com a eletroforese capilar como na miniaturização da instrumentação analítica para EC-CE-C4D, favorecendo a disseminação dessa poderosa combinação de três técnicas eletroquímicas. / The direct couple of electrochemical cell (EC) with the inlet of the capillary electrophoresis (CE) equipment, recently demonstrated, has allowed the determination of radical anions; to perform electrochemical preconcentration of traces of heavy metals, followed by stripping, injection, separation and detection; and the generation of charged species by electrochemical oxidation of neutral molecules, e.g. primary alcohols and glycerol. Employing the EC-CE-C4D system developed by our group, the simultaneous determination of cations, anions (in the counter EOF mode) and neutral species (after electrochemical derivatization) was demonstrated for the first time and a mouthwash (Listerine® Tartar Control) was used as a real sample. Although constant and reproducible, the conversion of primary alcohols into carboxylates had a low yield (~16%), under the adopted conditions, 1.6 V vs. Ag/AgClKCl 3M using platinum electrode in acid medium (5 mmol L-1 HNO3 / 1 mmol L-1 HCl). Thus, the yield of carboxylates was studied for the oxidation of alcohols (C2 &#8722; C5) on two electrode materials (gold and platinum) in different media (acid, neutral and alkaline). After the electrooxidation step an aliquot of the derivatized sample was automatically injected into the capillary (50 &#181;m i.d., 45 cm in length and 20 cm up to detector) by applying 5 kPa during 5 s. The separation was carried out applying 30 kV between the capillary ends previously filled with 30 mmol L-1 Tris / 10 mmol L-1 HCl BGE. Cyclic voltammograms show higher current density for alcohols oxidation in alkaline medium than in acid one both on gold and platinum electrodes. On the other hand the yields of carboxylic acids were higher in acidic medium. Besides that, only on gold electrode some selectivity for the carboxylate formation was observed favoring the conversion of the short chain alcohols. In order to meet the current needs for methodologies that allow the monitoring of the electrooxidation of glycerol in electrochemical reactors, a method was also developed that allowed the determination of glycerol and some of its possible neutral oxidation products, such as glyceraldehyde and dihydroxyacetone, by exploring the formation of borate complexes (provided in the BGE composed of 60 mmol L-1 H3BO3 / 30 mmol L-1 LiOH), together with ionizable ones like carboxylic acids. The employed CE equipment with two C4D detectors allowed the evaluation of the interaction between some carboxylic acids and the EOF modifiers, Polybrene® and CTAB, using 30 mmol L-1 MES / 30 mmol L-1 His as BGE. Aligned with a current trend of analytical instrumentation, the miniaturized EC-CE-C4D system was attempted. For that, a new method for manufacturing microdevices in glass, based on paraffin-assisted CO2 laser ablation, was developed as an alternative to costly wet-etching methods. The devices obtained by this method presented channels of semicircular profile and the dimensions could be controlled by varying the laser power and/or ablation velocity. Due to remaining challenges in the construction of a complete laser ablated EC-CE-C4D system on glass, a miniaturized system based on a hybrid approach is presented in the thesis, by taking advantage of the more defined and favorable characteristics of the well known fused silica capillary tubes used in CE. This system allowed the quantitative determination of methanol in the presence of high ethanol concentration by taking advantage of the higher yield of short-chain carboxylic acid formation on gold in acidic medium. The first application was the monitoring of the amount of methanol and ethanol in the initial fractions collected during the fractional distillation process in the production of corn whiskey (moonshine) made in the laboratory. The conditions that showed the best results with the hybrid EC-CE-C4D system included a 100-fold dilution of the sample in 2 mmol L-1 HNO3, electrooxidation at 1.4 V vs. Ag for 60 s, electrokinetic injection into the capillary by applying 3 kV for 4 s and separation of the carboxylates carried out under 3 kV between the ends of the capillary (50 &#181;m i.d., 15 cm in length and 12 cm up to detector) previously filled with 10 mmol L-1 CHES / 5 mmol L-1 NaOH, used as BGE. Analysis of the first distilled fractions of labmade moonshine showed an increase in ethanol concentration (ranging from ~ 80% to ~ 100%) and a simultaneous decrease in methanol concentration (ranging from 4% to ~ 0.1%). In short, both the range of applications of electrochemical derivatization hyphenated with capillary electrophoresis as well the miniaturization of analytical instrumentation for EC-CE-C4D were improved, favoring the dissemination of this powerful combination of three electrochemical techniques.
28

Eletroforese capilar com derivatização eletroquímica de compostos neutros: novas aplicações, otimização e miniaturização do sistema em fluxo EC-CE-C4D / Capillary Electrophoresis with Electrochemical Derivatization of Neutral Compounds: New Application, Optimization and Miniaturization of the Flow System EC-CE-C4D

Mauro Sergio Ferreira Santos 12 December 2016 (has links)
A combinação de célula eletroquímica (EC) com a entrada do equipamento de eletroforese capilar (CE), apesar de recente, tem permitido realizar determinação de ânions radicais; pré-concentração eletroquímica de metais pesados, seguida de redissolução, separação e detecção; bem como monitorar produtos carregados formados por oxidação eletrocatalítica de espécies neutras, como álcoois primários e glicerol. Empregando o sistema EC-CE-C4D desenvolvido pelo grupo, a determinação simultânea de cátions, ânions (no contra fluxo) e espécies neutras (detectadas após derivatização eletroquímica) foi demonstrada pela primeira vez, tendo o antisséptico bucal (Listerine® Tartar Control) como amostra real. Embora constante e reprodutível, a conversão dos álcoois primários nos respectivos carboxilatos apresentou rendimento relativamente baixo, ~16%, nas condições anteriormente adotadas, 1,6 V vs. Ag/AgClKCl 3M empregando eletrodo de platina em meio ácido (HNO3 5 mmol L-1 / HCl 1 mmol L-1). Dessa maneira, avaliou-se a oxidação de álcoois primários de cadeia normal (C2 &#8722; C5) sobre diferentes materiais de eletrodo (ouro e platina) em diferentes meios (ácido, neutro e alcalino). Os carboxilatos gerados foram monitorados injetando uma alíquota da amostra derivatizada no capilar (50 &#181;m d.i., 45 cm de comprimento e 20 cm efetivo) aplicando 5 kPa durante 5 s, e durante as separações, 30 kV foi aplicado entre as extremidades do capilar preenchido com Tris 30 mmol L-1 / HCl 10 mmol L-1 usado como BGE. Os resultados obtidos com o sistema EC-CE-C4D apontaram maior conversão dos álcoois nos respectivos ácidos carboxílicos em meio ácido, tanto em ouro quanto em platina. Adicionalmente, em eletrodo de ouro a formação dos carboxilatos apresentou certa seletividade não observada sobre platina, favorecendo a conversão dos álcoois de cadeia menor. Noutra vertente, buscando atender as necessidades atuais por metodologias que possibilitem monitorar a eletrooxidação do glicerol em reatores eletroquímicos, desenvolveu-se um método que permitiu determinar simultaneamente o glicerol e alguns de seus possíveis produtos de oxidação neutros, como gliceraldeído e dihidroxiacetona, explorando a formação de complexo carregado com borato (presente no BGE composto por H3BO3 60 mmol L-1 / LiOH 30 mmol L-1), além dos produtos ionizáveis (ácidos carboxílicos) que são comumente analisados por CE. O equipamento de CE utilizado, munido de dois detectores C4D, também permitiu avaliar a interação de alguns ácidos carboxílicos com os modificadores de EOF, Polybrene® e CTAB, empregando MES 30 mmol L-1 / His 30 mmol L-1 como BGE. Seguindo a atual tendência à miniaturização de sistemas analíticos, avaliou-se a possibilidade de construir um sistema EC-CE-C4D miniaturizado. Para isso, um novo método para fabricação de microdispositivos em vidro, baseado em ablação a laser de CO2 assistida por parafina, como alternativa aos dispendiosos métodos de corrosão por via úmida foi desenvolvido. Os dispositivos obtidos por esse método apresentaram canais de perfil semicircular, e as dimensões puderam ser controladas variando a potência e/ou a velocidade de ablação do laser. Contudo, pelos desafios ainda encontrados para se construir um sistema EC-CE-C4D completo em substrato de vidro por ablação a laser de CO2, optou-se por iniciar a miniaturização do sistema EC-CE-C4D com um sistema híbrido em que se aproveita as características mais bem definidas e favoráveis dos tubos capilares de sílica fundida usados em CE convencional. Esse sistema permitiu a determinação quantitativa de metanol na presença de alta concentração de etanol, possibilitando, numa primeira aplicação, realizar o monitoramento da quantidade de metanol e etanol nas frações iniciais coletada durante o processo de destilação fracionada na produção de uísque de milho (moonshine) feito em laboratório. Visto a maior seletividade para conversão dos álcoois de cadeia menor obtidas em eletrodo de ouro e meio ácido, esse foi escolhido para a presente aplicação. As condições que apresentaram melhores resultados no sistema híbrido EC-CE-C4D abrangeram diluição de 100 vezes da amostra em HNO3 2 mmol L-1, eletrooxidação a 1,4 V vs. Ag durante 60 s, injeção eletrocinética no capilar mediante aplicação de 3 kV durante 4 s, e a separação dos carboxilatos realizada aplicando 3 kV entre as extremidades do capilar (50 &#181;m d.i., 15 cm de comprimento com 12 cm efetivo), preenchido com CHES 10 mmol L-1 / NaOH 5 mmol L-1, usado como BGE. A análise das primeiras frações destiladas da \"labmade moonshine\" apresentou um aumento na concentração de etanol (variando de ~80 % a ~100 %) e simultâneo decréscimo da concentração de metanol (variando de 4 % a ~0,1 %). Em suma, avançou-se tanto no leque de aplicações da derivatização eletroquímica hifenizada com a eletroforese capilar como na miniaturização da instrumentação analítica para EC-CE-C4D, favorecendo a disseminação dessa poderosa combinação de três técnicas eletroquímicas. / The direct couple of electrochemical cell (EC) with the inlet of the capillary electrophoresis (CE) equipment, recently demonstrated, has allowed the determination of radical anions; to perform electrochemical preconcentration of traces of heavy metals, followed by stripping, injection, separation and detection; and the generation of charged species by electrochemical oxidation of neutral molecules, e.g. primary alcohols and glycerol. Employing the EC-CE-C4D system developed by our group, the simultaneous determination of cations, anions (in the counter EOF mode) and neutral species (after electrochemical derivatization) was demonstrated for the first time and a mouthwash (Listerine® Tartar Control) was used as a real sample. Although constant and reproducible, the conversion of primary alcohols into carboxylates had a low yield (~16%), under the adopted conditions, 1.6 V vs. Ag/AgClKCl 3M using platinum electrode in acid medium (5 mmol L-1 HNO3 / 1 mmol L-1 HCl). Thus, the yield of carboxylates was studied for the oxidation of alcohols (C2 &#8722; C5) on two electrode materials (gold and platinum) in different media (acid, neutral and alkaline). After the electrooxidation step an aliquot of the derivatized sample was automatically injected into the capillary (50 &#181;m i.d., 45 cm in length and 20 cm up to detector) by applying 5 kPa during 5 s. The separation was carried out applying 30 kV between the capillary ends previously filled with 30 mmol L-1 Tris / 10 mmol L-1 HCl BGE. Cyclic voltammograms show higher current density for alcohols oxidation in alkaline medium than in acid one both on gold and platinum electrodes. On the other hand the yields of carboxylic acids were higher in acidic medium. Besides that, only on gold electrode some selectivity for the carboxylate formation was observed favoring the conversion of the short chain alcohols. In order to meet the current needs for methodologies that allow the monitoring of the electrooxidation of glycerol in electrochemical reactors, a method was also developed that allowed the determination of glycerol and some of its possible neutral oxidation products, such as glyceraldehyde and dihydroxyacetone, by exploring the formation of borate complexes (provided in the BGE composed of 60 mmol L-1 H3BO3 / 30 mmol L-1 LiOH), together with ionizable ones like carboxylic acids. The employed CE equipment with two C4D detectors allowed the evaluation of the interaction between some carboxylic acids and the EOF modifiers, Polybrene® and CTAB, using 30 mmol L-1 MES / 30 mmol L-1 His as BGE. Aligned with a current trend of analytical instrumentation, the miniaturized EC-CE-C4D system was attempted. For that, a new method for manufacturing microdevices in glass, based on paraffin-assisted CO2 laser ablation, was developed as an alternative to costly wet-etching methods. The devices obtained by this method presented channels of semicircular profile and the dimensions could be controlled by varying the laser power and/or ablation velocity. Due to remaining challenges in the construction of a complete laser ablated EC-CE-C4D system on glass, a miniaturized system based on a hybrid approach is presented in the thesis, by taking advantage of the more defined and favorable characteristics of the well known fused silica capillary tubes used in CE. This system allowed the quantitative determination of methanol in the presence of high ethanol concentration by taking advantage of the higher yield of short-chain carboxylic acid formation on gold in acidic medium. The first application was the monitoring of the amount of methanol and ethanol in the initial fractions collected during the fractional distillation process in the production of corn whiskey (moonshine) made in the laboratory. The conditions that showed the best results with the hybrid EC-CE-C4D system included a 100-fold dilution of the sample in 2 mmol L-1 HNO3, electrooxidation at 1.4 V vs. Ag for 60 s, electrokinetic injection into the capillary by applying 3 kV for 4 s and separation of the carboxylates carried out under 3 kV between the ends of the capillary (50 &#181;m i.d., 15 cm in length and 12 cm up to detector) previously filled with 10 mmol L-1 CHES / 5 mmol L-1 NaOH, used as BGE. Analysis of the first distilled fractions of labmade moonshine showed an increase in ethanol concentration (ranging from ~ 80% to ~ 100%) and a simultaneous decrease in methanol concentration (ranging from 4% to ~ 0.1%). In short, both the range of applications of electrochemical derivatization hyphenated with capillary electrophoresis as well the miniaturization of analytical instrumentation for EC-CE-C4D were improved, favoring the dissemination of this powerful combination of three electrochemical techniques.
29

A derivatização na determinação de proteínas e aminoácidos em fluidos biológicos / Derivatization in the determination of proteins and amino acids in biological fluids

Guarilha Junior, Orlando 06 June 2003 (has links)
No presente trabalho são apresentadas análises de amostras de proteínas totais e aminoácidos empregando-se os reagentes p-benzoquinona e tetraamin cobre (II). No caso do reagente p-benzoquinona, as análises foram feitas através de um sistema inédito em fluxo, no qual a mistura reacional passava através de um reator composto de um tubo capilar de aço inoxidável aquecido num banho de glicerina. Os derivados formados passavam através de uma cela de fluxo acoplada a um espectrofotômetro, onde eram feitas as leituras das absorbâncias. Este método se mostrou mais rápido em relação àquele feito em banho-maria. A utilização de um sistema de análise por injeção em fluxo (FIA) com o reagente tetraamin cobre (II), permitiu que as análises fossem feitas de forma rápida, a baixo custo e com a vantagem de não necessitarem de aquecimento, como no caso da p-benzoquinona. Os resultados das análises de amostras de albumina humana obtidos em ambos os métodos acima apresentaram boa concordância quando comparados àqueles obtidos pelo método Kjeldahl para as mesmas amostras. / This work describes two methods for analysis of total proteins and aminoacids using both p-benzoquinone (PBQ) and tetraamin copper (II) reagents. With the p-benzoquinone reagent the method was performed by an original flow system made with stainless steel capillary tubing, conveniently heated into a glycerin bath, where the reactional mixture travels in its way to the detector. The derivate products are carried out to a flow cell adjusted to a spectrophotometer where the absorbances are measured. This method was efficient, with a fair cost, and providing results very faster than in the batch mode of operation. The second method, using the tetraamin copper (II) reagent, was performed by a common flow injection system (FIA). When compared with the PBQ method, the FIA tetramin copper (II) method was also rapid, efficient, with a fair cost and with the great advantage of simplicity, once it is performed at room temperature. The results obtained with human albumine samples using both methods are in agreement with those ones obtained by the Kjeldahl method for the same samples.
30

A derivatização na determinação de proteínas e aminoácidos em fluidos biológicos / Derivatization in the determination of proteins and amino acids in biological fluids

Orlando Guarilha Junior 06 June 2003 (has links)
No presente trabalho são apresentadas análises de amostras de proteínas totais e aminoácidos empregando-se os reagentes p-benzoquinona e tetraamin cobre (II). No caso do reagente p-benzoquinona, as análises foram feitas através de um sistema inédito em fluxo, no qual a mistura reacional passava através de um reator composto de um tubo capilar de aço inoxidável aquecido num banho de glicerina. Os derivados formados passavam através de uma cela de fluxo acoplada a um espectrofotômetro, onde eram feitas as leituras das absorbâncias. Este método se mostrou mais rápido em relação àquele feito em banho-maria. A utilização de um sistema de análise por injeção em fluxo (FIA) com o reagente tetraamin cobre (II), permitiu que as análises fossem feitas de forma rápida, a baixo custo e com a vantagem de não necessitarem de aquecimento, como no caso da p-benzoquinona. Os resultados das análises de amostras de albumina humana obtidos em ambos os métodos acima apresentaram boa concordância quando comparados àqueles obtidos pelo método Kjeldahl para as mesmas amostras. / This work describes two methods for analysis of total proteins and aminoacids using both p-benzoquinone (PBQ) and tetraamin copper (II) reagents. With the p-benzoquinone reagent the method was performed by an original flow system made with stainless steel capillary tubing, conveniently heated into a glycerin bath, where the reactional mixture travels in its way to the detector. The derivate products are carried out to a flow cell adjusted to a spectrophotometer where the absorbances are measured. This method was efficient, with a fair cost, and providing results very faster than in the batch mode of operation. The second method, using the tetraamin copper (II) reagent, was performed by a common flow injection system (FIA). When compared with the PBQ method, the FIA tetramin copper (II) method was also rapid, efficient, with a fair cost and with the great advantage of simplicity, once it is performed at room temperature. The results obtained with human albumine samples using both methods are in agreement with those ones obtained by the Kjeldahl method for the same samples.

Page generated in 0.2683 seconds