• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 394
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 397
  • 312
  • 190
  • 146
  • 142
  • 100
  • 84
  • 50
  • 43
  • 42
  • 38
  • 37
  • 36
  • 36
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

Sistemas de análises químicas em fluxo explorando mecanismos de re-alimentação, calibração multivariada e outras abordagens para melhoria em desempenho / Flow systems exploiting feed-back mechanisms, multivariate calibration and other strategies for improving the analytical performance

Fortes, Paula Regina 30 June 2010 (has links)
Estudos foram conduzidos relativamente ao desempenho dos sistemas de análises em fluxo quando configurados como sistemas inteligentes, associados às técnicas de calibração multivariada ou empregando nanocristais como sensibilizadores. Ainda, melhorias relacionadas às modificações dos fluxos foram avaliadas, especialmente no que se refere à diálise em linha. Neste sentido, foi proposta uma nova estratégia para implementar determinações simultâneas de ferro e vanádio em ligas metálicas envolvendo cinética diferencial. O método baseava-se nas diferentes influências exercidas por Fe2+ e por V4+ na taxa de oxidação de íons iodeto por íons Cr6+ sob condições ácidas. Três diferentes alíquotas de amostra eram inseridas em um fluxo transportador / reagente de KI, confluindo posteriormente com um fluxo de K2Cr2O7. A sobreposição entre as três zonas de amostra estabelecidas resultava em uma zona de amostra complexa com diversos valores de absorbância. Medidas realizadas nos pontos de máximos e minímos do sinal registrado eram mais precisas e continham informações acerca dos diferentes estágios de desenvolvimento da reação e de diferentes condições de concentrações. Em outra estratégia, um sistema MPFS inteligente foi proposto para a determinação turbidimétrica sequencial de sulfato e cloreto em águas naturais. Ambos os métodos foram implementados no mesmo módulo de análises, proporcionando facilidades relativas ao: preparo de amostra em linha; adição de íons sulfato ou cloreto ao meio reacional para melhoria das condições de supersaturação; decisão em tempo real acerca da necessidade ou não da próxima análise. Inicialmente, determinava-se a concentração de cloreto presente na amostra, e este resultado era comparado com um valor pré-determinado. Se este fosse superior, a amostra era analisada novamente visando à determinação de sulfato. Caso contrário, uma nova amostra era analisada. A estratégia resultou em aumento da velocidade analítica e em boas figuras de mérito analítico. Estudos relativos à natureza do fluxo foram conduzidos avaliando-se o desempenho dos fluxos pulsados provenientes de bombas solenóide em relação à eficiência do transporte de massas, dispersão da zona de amostra relacionada com a mudança de sentido do fluxo e eficiência do processo de diálise quando comparados aos fluxos tipicamente laminares. Embora fosse observada a presença de vórtices, o número de Reynolds experimentalmente obtido demonstrou que o fluxo resultante não era turbulento. Porém seu perfil exibia características de mescla turbulenta, melhorando assim o desempenho relativo ao transporte de massas e redução da dispersão da zona de amostra. Entretanto, beneficios relativos a melhorias no processo de diálise foram ausentes devido provavelmente à alta pressão exercida dentre da câmara de diálise, com consequente deformação dos poros da membrana. Nestas situações, um sistema de análises híbrido (com fluxo laminar e mescla turbulenta) seria fortemente recomendado. Finalmente, a implementação de nanocristais quantum dots (QDs) como sensibilizadores em um sistema MPFS envolvendo reação quimioluminescente foi proposta para a determinação de glipizida e gliclazida em formulaçoes farmacêuticas. O método fundamentava-se na oxidação dos íons S2- por Ce4+ em meio ácido. Na presença dos analitos, a intensidade da radiação emitida era inibida. A influência do diâmetro médio dos nanocristais foi avaliada, e os critérios utilizados para o dimensionamento do sistema foram a repetibilidade, a reprodutibilidade e a sensibilidade analítica. Os analitos foram quantificados no mesmo módulo de análises, e boas figuras de mérito analítico foram verificadas. Os resultados obtidos se apresentaram concordantes com aqueles obtidos pela Farmacopéia Britânica / Studies focusing on performance of intelligent analytical flow systems, association with multivariate calibration or use of nanocrystals as sensitizers were carried out. Moreover, improvements related to modifications in flow pattern were evaluated with emphasis to in-line dialysis. To this end, a strategy for implementing simultaneous determinations of iron and vanadium in alloys relying on differential kinetics was proposed. The method was based on the influence of Fe2+ and V4+ on the rate of iodide oxidation by Cr6+ under acidic conditions. Three different plugs of the sample were sequentially inserted into an acidic KI reagent carrier stream, and a confluent K2Cr2O7 solution was added downstream. Overlap between the established plugs led to a complex sample zone with several regions of maximal and minimal absorbance values. Measurements performed on these regions were more precise and revealed the different degrees of reaction development. In another strategy, an intelligent MPFS was proposed for sequential turbidimetric determination of sulphate and chloride in natural waters. Both methods were implemented in the same manifold, providing facilities for: in-line sample cleanup; addition of low amounts of sulphate or chloride ions to the reaction medium for improving supersaturation conditions and real-time decision on the need for next assay. The sample was initially run for chloride determination, and the analytical signal was compared with a preset value. If higher, the sample was run again, now for sulphate determination. Otherwise, next sample was assayed. The strategy led to an increased sample throughput and good analytical figures of merit. Studies focusing on the flow pattern were carried out aiming at the evaluation of the influence of the pulsed flows delivered by solenoid pumps in relation to the efficiency of mass transfer, dispersion related to changes in flow direction of the sample zone and dialysis process as compared with typical laminar flow. Although the establishment of vortices were noted, the experimentally obtained Reynolds number showed that a turbulent flow was not established. Its pattern exhibited characteristics which improved the performance due to the enhanced radial mass transport inherent in turbulent mixing. Comparatively to laminar flow, beneficial aspects were noted in relation to sample dispersion and mass transfer. In relation to dialysis efficiency however process the benefits were not noted probably due to the high pressure inside the dialysis chamber, with consequent membrane pore deformation. In this situation, a hybrid flow analysis system (with laminar flow and turbulent mixing) might be recommended. Implementation of quantum dots nanocrystals (QDs NC) as sensitizers in a MPFS with chemiluminometric detection was proposed for the determinations of gliclazide and glipizide in pharmaceutical formulations. The method relied on the oxidation of sulphite by Ce4+ in acidic medium and, in the presence of the analytes, the emitted radiation of the Ce4+-SO3 2--CdTe QDs system was inhibited. Influence of crystal size was investigated, and the criteria for system optimization were the analytical repeatability, reproducibility and sensitivity. Both analytes were quantified in the same manifold, resulting in good analytical figures of merit. The results were in fairly good agreement with those obtained by the British Pharmacopoeia reference method
372

Força muscular respiratória, capacidade funcional, controle autonômico cardiovascular e função endotelial de pacientes com doença renal crônica / Respiratory muscle strength, functional capacity, autonomic cardiovascular control and endothelial function of patients with chronic renal disease

Scapini, Kátia Bilhar 14 February 2017 (has links)
INTRODUÇÃO: A doença renal crônica (DRC) é uma patologia progressiva e debilitante, que apresenta alta mortalidade devido a causas cardiovasculares. Pacientes com DRC apresentam alterações metabólicas e musculares que estão associadas com diminuição da capacidade funcional e baixa tolerância ao exercício, porém pouco se sabe sobre o acometimento da musculatura respiratória desses pacientes. Dessa forma, os objetivos primários deste estudo foram avaliar a força muscular respiratória (FMR) de pacientes com DRC e verificar a existência de associação da força da musculatura inspiratória com fatores de risco cardiovasculares já descritos na DRC. MÉTODOS: A amostra foi composta por pacientes com DRC (estádios 3 ao 5) (grupo DRC, n = 30) e por indivíduos saudáveis (grupo controle, C. n =11). Posteriormente, para fins de comparação, os pacientes com DRC foram divididos em dois grupos: pacientes com DRC em fase não dialítica (estádios 3 e 4 - grupo DRC-ND, n=12) e pacientes com DRC em hemodiálise (estádio 5 - grupo DRC-D, n = 18). Todos os indivíduos realizaram os seguintes procedimentos: manovacuometria digital para mensuração da pressão inspiratória máxima (PImax) e pressão expiratória máxima (PEmax); registro da pressão arterial (PA) batimento a batimento e do eletrocardiograma para mensuração das variáveis hemodinâmicas; registro da atividade simpática nervosa muscular (ANSM); avaliação da composição corporal por meio de bioimpedância; avaliação da velocidade de onda de pulso (VOP) carotídea-femoral; avaliação da função endotelial; teste ergoespirométrico para mensuração da capacidade funcional cardiorrespiratória. Para os indivíduos do grupo DRC-D as avaliações foram sempre realizadas no segundo dia interdialítico da semana. Posteriormente as curvas de pressão arterial registradas foram utilizadas para mensurar a variabilidade da frequência cardíaca (VFC) e da PA e para determinar o barorreflexo espontâneo. RESULTADOS: Os pacientes com DRC apresentam redução da FMR quando comparados ao grupo controle (PImax: DRC= 82,51 ± 24,39 vs. C= 115,20 ± 18,71 cmH2O; PEmax: DRC= 99,64 ± 19,86 vs. C= 138,90 ± 27,08 cmH2O). Não houve diferença nas pressões respiratórias entre os grupos DRC-D e DRC-ND. Além disso, os pacientes com DRC apresentam diminuição da VFC [SDNN: DRC = 19,03 (10,95 - 44,28) vs. C= 45,25 (28,45 - 76,86)ms], aumento do balanço simpatovagal (DRC= 3,42 ± 1,99 vs. C= 1,54 ±1,01), aumento da variância da PA sistólica [DRC= 48,60 (13,38 -149,00) vs. C= 29,76 (15,83 - 49,54) mmHg2, prejuízo tanto da ativação (DRC= 0,40 ± 0,15 vs. C= 0,72 ± 0,10) quanto da sensibilidade barorreflexa (DRC= 7,98 ± 4,37 vs. C= 20,87 ± 10,68 ms/mmHg), bem como, aumento da ANSM (DRC= 20,44 ± 3,88 vs. C= 17,75 ± 1,46 bursts/min). Para a maioria dos índices de VFC o grupo DRC-D apresentou maior comprometimento do que o grupo DRC-ND. Contudo, o balanço simpatovagal, a variância da PA sistólica, a ANSM e a ativação do barorreflexo não foi diferente entre os grupos DRC-D e DRC-ND. Além disso, os pacientes com DRC apresentaram menor consumo de oxigênio que os indivíduos saudáveis (DRC= 29,1 ± 7,76 vs. C= 38,5 ± 7,9 ml/kg/min), redução da função endotelial (DRC= 4,90 ± 4,62 vs. C =8,70 ± 2,19%) e aumento da VOP (DRC= 8,30 (6,15 - 12,2) vs. C= 6,55 (5,4 - 7,8) m/s) quando comparado ao grupo controle, sendo que não foram observadas diferenças entre os grupos DRC-D e DRC-ND para estas variáveis. Quanto a composição corporal, os indivíduos com DRC apresentaram menor massa corporal celular, menor massa magra, maior massa gorda, menor água intracelular, e maior porcentagem de água extracelular quando comparados ao grupo controle. Não foram observadas diferenças na composição corporal entre o grupo DRC-D e DRC-ND. Houve associação positiva entre a força muscular inspiratória e o consumo máximo de oxigênio, bem como entre a PImax e níveis séricos de albumina nos indivíduos com DRC. CONCLUSÕES: Pacientes com DRC, mesmo em fase não dialítica, apresentam comprometimento da FMR, principalmente da PImax, bem como redução da capacidade funcional cardiorrespiratória, sendo que, existe uma associação entre a PImax e o consumo máximo de oxigênio. Além disso, os pacientes com DRC apresentam prejuízo da VFC e da sensibilidade barorreflexa, aumento do balanço simpatovagal, da ANSM e alterações vasculares, que embora pareçam ser mais evidentes nos doentes renais em fase dialítica, já podem ser observadas também na fase pré-dialítica da DRC / INTRODUCTION: Chronic kidney disease (CKD) is a progressive and debilitating condition that presents high mortality due to cardiovascular causes. Patients with CKD have metabolic and muscular changes that are associated with decreased functional capacity and low tolerance to exercise, but little is known about the involvement of the respiratory muscles in these population. Thus, the primary objectives of this study were to evaluate the respiratory muscle strength (RMS) of patients with CKD and to verify the existence of an association of inspiratory muscle strength with cardiovascular risk factors already described in CKD. METHODS: The sample consisted of patients with CKD (stages 3 to 5) (CKD group, n = 30) and healthy individuals (control group, C n = 11). For comparison purposes, patients with CKD were divided into two groups: non-dialytic CKD patients (stages 3 and 4 - CKD-ND group, n = 12) and patients with CKD on hemodialysis (stage 5 - group CKD-D, n = 18). All subjects performed the following procedures: digital manovacuometry to measure maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP); recording of blood pressure (BP) beat-to-beat and electrocardiogram for measurement of hemodynamic variables; register of sympathetic nervous muscle activity (SNMA); assessment of body composition by bioimpedance; assessment of carotid-femoral pulse wave velocity (PWV); evaluation of endothelial function; ergospirometric test for measurement of cardiorespiratory functional capacity. For the subjects in the CKD-D group the evaluations were always performed on the second interdialytic day of the week. Subsequently, the recorded blood pressure curves were used to measure heart rate (HRV) and BP variability and to determine spontaneous baroreflex. RESULTS: Patients with CKD had a reduction in RMS when compared to the control group (MIP: CKD = 82.51 ± 24.39 vs. C = 115.20 ± 18.71 cmH2O; MEP: CKD = 99.64 ± 19, 86 vs. C = 138.90 ± 27.08 cm H2O). There was no difference in respiratory pressures between the CKD-D and the CKD-ND groups. In addition, patients with CKD had a decrease in HRV [SDNN: CKD = 19.03 (10.95 - 44.28) vs. C = 45.25 (28.45 - 76.86) ms], increased sympatovagal balance (CKD = 3.42 ± 1.99 vs. C = 1.54 ± 1.01), increased systolic BP variance [CKD = 48.60 (13.38 -149.00) vs. C = 29.76 (15.83 - 49.54) mmHg2, impairment of both activation (CKD = 0.40 ± 0.15 vs C = 0.72 ± 0.10) and baroreflex sensitivity (CKD = 7.98 ± 4.37 vs. C = 20.87 ± 10.68 ms/mmHg), as well as increased SNMA (CKD = 20.44 ± 3.88 vs. C = 17.75 ± 1.46 bursts/min). For most HRV scores, the CKD-D group presented greater impairment than the CKD-ND group. However, sympathovagal balance, systolic BP variance, SNMA and baroreflex activation were not different between the CKD-D and CKD-ND groups. In addition, patients with CKD had lower oxygen consumption than healthy subjects (CKD = 29.1 ± 7.76 vs. C = 38.5 ± 7.9 ml/kg/min), reduction of endothelial function (CKD = 4.90 ± 4.62 vs. C = 8.70 ± 2.19 %) and increased PWV (CKD = 8.30 (6.15 - 12.2) vs. C = 6.55 (5, 4 - 7.8) m/s) when compared to control group, and no differences were observed between the CKD-D and CKD-ND groups for these variables. Regarding body composition, individuals with CKD had lower cellular body mass, lower lean mass, higher fat mass, lower intracellular water, and higher percentage of extracellular water when compared to control group. No differences were observed in body composition between the CKD-D and CKD-ND groups. There was a positive association between inspiratory muscle strength and maximum oxygen consumption, as well as between MIP and serum albumin levels in individuals with CKD. CONCLUSIONS: Patients with CKD, even in the non-dialytic phase, have FMR impairment, mainly MIP, as well as reduction of cardiorespiratory functional capacity, and there is an association between MIP and maximal oxygen consumption in this population. In addition, patients with CKD have impairment of HRV and baroreflex sensitivity, increased sympatovagal balance, SNMA, and vascular alterations, that although they may appear to be more evident in renal dialysis patients, may also be observed in the predialytic phase of DRC
373

O impacto de reúso de dialisadores nos marcadores de estresse oxidativo e inflamatórios em pacientes em hemodiálise / Evaluation of oxidative stress and inflamatory markers on hemodialysis patients with and without dialysers reuse

Furlan, Carla Barbosa Muraro 27 March 2014 (has links)
A morbimortalidade dos pacientes em hemodiálise permanece alta apesar da evolução tecnológica do procedimento, sendo que os eventos cardiovasculares são a sua principal causa. Estes desencadeados pela alta prevalência de fatores de risco tradicionais, fatores relacionados ao procedimento dialítico e estresse oxidativo. Considerando o procedimento dialítico e o estresse oxidativo, foi avaliado o quanto a habitual prática de reuso de dialisadores/RD (difundida nas Américas e amparada principalmente por questões econômicas) e uso único de dialisadores, influenciam nos marcadores inflamatórios e de estresse oxidativo. Para isto, foram utilizados como marcadores laboratoriais as medidas de PCR ultrassensível (u PCR), interleucina 6 (IL6), a determinação de substâncias reativas ao ácido tiobarbitúrico (TBARS), superóxido dismutase (SOD), glutationa (GSH) e albumina, em 29 pacientes em tratamento de hemodiálise. Estes pacientes encontravam-se em tratamento com dialisadores de alto fluxo do tipo polieterssulfona e reuso manual, e ao iniciar este estudo foram programados 3 ciclos sequenciais com duração de 6 semanas com as seguintes características: primeiro ciclo (uso único de dialisadores;); segundo ciclo (reuso de dialisadores); terceiro ciclo (reuso de dialisadores e administração de N-acetilcisteína/NAC, na dose de 1200 mg/dia). Foram coletadas amostras de sangue de cada paciente no início e final da última sessão de hemodiálise anteriormente ao início dos ciclos (denominado Período 1) e no início e final da última sessão de hemodiálise de cada ciclo (denominados Períodos 2, 3 e 4 respectivamente). O TBARS aumentou no período de uso único. Todas as demais variáveis não apresentaram diferença significativa. Os resultados indicaram que o RD pode proporcionar uma melhora no estresse oxidativo. O uso único foi associado com maior estresse oxidativo. Não foi encontrado nenhum benefício adicional com NAC / The morbidity and mortality of patients undergoing hemodialysis remains high despite the technological development of this procedure, and cardiovascular events are the main causes of morbidity and mortality. These cardiovascular events are triggered by the high prevalence of traditional risk factors, factors associated with dialysis procedures, and oxidative stress. Considering the factors associated with dialysis procedures and oxidative stress, we assessed how dialyzer reuse (DR; widespread in the Americas, especially because of economic issues) and use of single-use dialyzers influence oxidative stress and inflammatory markers. We used ultrasensitive PCR (u-PCR) to measure levels of the laboratory markers interleukin-6 (IL6), thiobarbituric acid reactive substances (TBARS), superoxide dismutase (SOD), glutathione (GSH), and albumin in 29 patients undergoing hemodialysis treatment. These patients were receiving treatment with polyethersulfone high-flux dialyzers and manual reuse. In the initial phase of this study, the 3 following sequential cycles, each lasting 6 weeks, were scheduled: first cycle (single-use dialyzers); second cycle (DR); and third cycle (DR and administration of N-acetylcysteine [NAC] at a dose of 1200 mg/day). Blood samples were collected from each patient at the beginning and end of the last hemodialysis session that preceded the start of the cycles (termed Period 1), and at the beginning and end of the last hemodialysis session of each cycle (termed Periods 2, 3, and 4, respectively). The levels of TBARS increased during the single-use period. The remaining variables did not show significant differences. The results indicated that DR may ameliorate oxidative stress. Single-use dialyzers were associated with higher oxidative stress. No additional benefit was found with use of NAC
374

Avaliação das concentrações de anticorpos aos sorotipos 4, 6B, 9V, 14, 18C, 19F e 23F de Streptococcus pneumoniae antes e depois da aplicação da vacina conjugada 7 - valente, em crianças com insuficiência renal crônica em tratamento conservador / Evaluation of concentration of antibody against the serotypes 4, 6B, 9V, 14, 18C, 19F and 23F to Streptococcus pneumoniae capsular polysaccharide before and after 7 - valent conjugated pneumococcal vaccine, in children with chronic renal failure (CRF) in conservative treatment and dialysis

Simone Vieira 21 August 2007 (has links)
Introdução: A vacina pneumocócica é recomendada para crianças com IRC, pelo maior risco de adquirir a forma invasiva da doença. O Streptococcus pneumoniae é o principal agente etiológico causador de pneumonia e otite média aguda, e a segunda causa de meningite na criança. A vacina conjugada 7 - valente tem se mostrado imunogênica e com efeito duradouro em crianças normais, porém em pacientes com IRC, devido às alterações imunológicas associadas à uremia, pode resultar uma resposta sub - ótima e de vida curta. Objetivo: Determinar as concentrações de anticorpos da classe IgG contra os sorotipos 4,6B, 9V, 14, 18C, 19F e 23 F do Streptococcus pneumoniae, antes e depois da administração da vacina antipneumocócica conjugada 7 - valente, em crianças portadoras de insuficiência renal crônica em tratamento conservador e diálise, e comparar a resposta entre eles. Métodos: Selecionamos 48 crianças, com idade de 1 ano a 9 anos, portadoras de IRC, com depuração de creatinina menor ou igual a 70 ml/min/1,73m 2 , calculada pela fórmula de Schwartz, divididos em: grupo 1 (G1, tratamento conservador), e grupo 2 (G2,tratamento dialítico). Os pacientes receberam duas doses da vacina conjugada 7 - valente, com intervalo de 60 dias. A sorologia foi colhida antes da primeira dose, e 30 a 60 dias após o reforço. Os títulos de anticorpos para os sorotipos presentes na vacina (4, 6B, 9V, 14, 18C, 19F, 23F) foram determinados pelo método imunoenzimático (ELISA). Resultados: A análise da concentração pré - vacinal de IgG mostrou maior percentual dos pacientes do grupo 1 e 2 com IgG <0,6 para os sorotipos 4, 9 e 18, e maior percentual com IgG maior ou igual a 1,3 ug/ml para os sorotipos 14 e 19. Para avaliar a concentração de IgG pós - vacinal foi utilizado o cálculo de freqüências com intervalo de confiança 95%(IC95), para os 7 sorotipos nos 2 grupos, utilizando-se 3 critérios : Critério A: IgG pós vacinal maior ou igual a 1,3 ug/ml, por este critério verificou-se freqüência de resposta do G1 de 0,650 (IC95: 0,407-0,864) a 1,0 (IC95: 0,663 - 1,0) e do G2 de 0,777 (IC95: 0,399 -0,971) a 1,0 (IC95: 0,663 - 1,0), critério B: ou seja, delta (pré/pós) maior ou igual a 4X, freqüência de resposta G1 de 0,458 (IC95: 0,255 - 0,671) a 0,708 (IC95%: 0,488 - 0,873) e do G2 de 0,458 (IC95%: 0,255 - 0,671) a 0,708 (IC95%: 0,488 - 0,973), e critério C:isto é, delta (pré/pós) maior ou igual a 4X e IgG maior ou igual a 1,3 ug/ml, freqüência de resposta do G1 de 0,416 (IC95%: 0,221 - 0,633) a 0,625 (IC95%: 0,406 - 0,811) e do G2 de 0,416 (IC95%: 0,221 - 0,633) a 0,666 (IC95%: 0,447 - 0,843). G1 e G2 mostraram comportamento semelhante na análise das freqüências de resposta, segundo os 3 critérios. Conclusão: Este estudo é pioneiro na avaliação da vacina antipneumocócica conjugada em crianças com IRC, e demonstrou uma boa resposta para cada critério analisado separadamente, com comportamento semelhante nos 2 grupos. A dificuldade inerente à definição de critérios de soroconversão, demonstra a necessidade de estudos multicêntricos com acompanhamento clínico e laboratorial em longo prazo para avaliar a sustentabilidade da soroconversão e a imunogenicidade da vacina. / Introduction: The pneumococcal vaccine is recommended for children with CRF due to their increased risk in acquiring the invasive form of the disease. Streptococcus pneumoniae is the main etiological agent that causes pneumonia and acute middle otitis and the second cause of meningitis in children. The 7-valent conjugated pneumococcal vaccine has been shown to be immunogenic and to have a lasting effect in normal children; however, in children with CRF, the vaccine can produce a suboptimal and short-lasting response due to the immunological alterations associated to uremia. Objective: to determine pneumococcal IgG antibodies to serotypes 4, 6B, 9V, 14, 18C, 19F e 23 F before and after 7 - valent conjugated pneumococcal vaccine, in children with chronic renal failure in conservative treatment and dialysis. Methods: 48 children with CRF, aged 1 to 9 years, with a creatinine clearance of menor ou igual a 70 ml/min/1.73 calculated by the Schwartz formula, were selected for the present study and divided in two groups: Group 1: conservative treatment and Group 2: dialytic treatment. The patients received two doses of the 7- valent conjugated vaccine, with a 60-day interval between them. Serological samples were collected before the first dose and 30 to 60 days after the second one. Antibody titers for the serotypes present in the vaccine (4, 6B, 9V, 14, 18C, 19F, 23F) were determined by the immunoenzymatic method (ELISA). Results: The analysis of the pre-vaccinal IgG concentration showed a higher percentage of patients from Groups 1 and 2 with IgG < 0.6 for the serotypes 4, 9 and 18, and a higher percentage with pre-vaccinal IgG maior ou igual a 1.3 ug/ml for the serotypes 14 and 19. To assess the post-vaccinal IgG concentration, the calculation of frequencies with 95% confidence interval (95CI) was employed for the 7 serotypes in both groups, using three criteria: Criterion A: post-vaccinal IgG maior ou igual a 1.3 ug/ml, this criterion verified the frequency of response from G1 0,650 (IC95: 0,407-0,864) to 1,0 (IC95: 0,663 - 1,0) and G2 0,777 (IC95: 0,399 - 0,971) to 1,0 (IC95: 0,663 - 1,0), criterion B: i.e., delta (pre/post) maior ou igual a 4X, frequency of response from G1 0,458 (95CI: 0.255 ? 0.671) to 0.708 (95CI: 0.488 - 0.873) and G2 0,458 (IC95: 0,255 - 0,671) to 0,708 (IC95: 0,488 - 0,873); criterion C: i.e., delta (pre/post) ?4X and IgG maior ou igual a 1.3 ug/ml, frequency of response from G1 0.416 (95CI: 0.221 - 0.633) to 0,625(95CI: 0,406 - 0,811) and G2 0,416 (9CI: 0,221 - 0,633) to 0.666 (95CI: 0.447 - 0.843). Groups 1 and 2 showed similar behavior at the analysis of response frequencies according to the three criteria. Conclusion: this is the first study to assess the conjugated pneumococcal vaccine in children with CRF, which showed good response, with a similar behavior in both groups. The inherent difficulty in defining criteria for seroconversion demonstrates the need for multicentric studies with long-term clinical and laboratory follow up, in order to assess the seroconversion duration and the vaccine immunogenicity.
375

Dialisador capilar reutilizado e de uso único em hemodiálise : implicações na saúde dos profissionais, em desfechos clínicos e custos / Single-use and reused capillary dialyzer in hemodialysis : implications for the health of professionals, clinical outcomes and costs / Dializador capilar reutilizado y de un solo uso en hemodiálisis : implicaciones para la salud de los profesionales, desenlaces clínicos y costos

Silva, Olvani Martins da January 2016 (has links)
A reutilização do dialisador capilar em hemodiálise é uma prática realizada em muitos países, apesar de não haver consenso sobre sua segurança e eficácia em comparação ao dialisador de uso único. Em relação ao uso único, apontam-se os custos como grande entrave e a preocupação com o aumento do lixo hospitalar. No que se refere aos riscos do reuso, aponta-se a exposição dos profissionais aos produtos químicos necessários à realização do processo de reutilização, assim como movimentos repetitivos envolvidos na dinâmica dessa técnica; somadas a isto, a redução da eficiência da membrana, a contaminação do sistema, as infecções cruzadas, as reações pirogênicas e as bacteremias. Nesse sentido, tornam-se relevantes estudos que investiguem o efeito da adoção desses métodos nesses desfechos. Objetivos: Comparar as implicações do dialisador reutilizado (reuso) com as do utilizado uma única vez (uso único) na saúde dos profissionais, nos desfechos clínicos e custos de pacientes em hemodiálise. Métodos: Estudo longitudinal, com coleta de dados retrospectiva, realizado em um Hospital Público Universitário (Janeiro de 2015 a Fevereiro de 2016). Foram incluídos 18 técnicos de enfermagem e 34 pacientes renais crônicos submetidos à hemodiálise nos dois períodos do estudo (período de reuso e período de uso único), por meio de cateter, fístula ou enxerto, com fluxo de sangue de pelo menos 300 ml/min. e tempo de diálise definido entre três a quatro horas por sessão. Considerou-se como desfechos primários os distúrbios osteomusculares, irritação ocular, as dermatoses, afastamento do trabalho e uso de medicações. Como secundários, hemodinâmica, volemia, exames laboratoriais, reações pirogênicas, bacteremias, uso de antibióticos e custos diretos e indiretos do procedimento. Projeto aprovado no Comitê de Ética da instituição. Resultados: O tempo médio de trabalho dos 18 técnicos de enfermagem foi de 12±7 anos. Durante o período de reutilização do dialisador, houve sete notificações. Verificou-se uma taxa de exposição ao uso de medicamentos de 6,7 dias para cada 1.000 profissionais no período de reuso do dialisador; 1,52 dias de exposição à medicação para cada 1.000 profissionais no período de uso único do dialisador (RDI= 4,4; IC 95%: 2.182-9.805); os dias de afastamento foram semelhantes entre os períodos. Nos 34 pacientes estudados nos dois períodos, foram semelhantes os parâmetros hemodinâmicos e volêmicos; houve redução de ureia pós-diálise, creatinina, fósforo, ferritina, hematócrito e hemoglobina durante o uso único do dialisador; foi observado um risco 91% menor de pirogenia no uso único do dialisador, se comparado ao período de reuso (RC= 0,091; IC 95%: 0,002-0,625). Não houve diferença significativa na presença da bacteremias (p= 0,125); a vancomicina foi utilizada empiricamente para tratar a pirogenia. Para cada paciente em hemodiálise utilizando o dialisador reutilizado, o valor médio foi R$ 23,18; e com o dialisador de uso único foi de R$ 39,77 (p= 0,002). O custo indireto médio mensal durante o período de reuso foi de R$ 168,07 (R$ 0,37 por sessão); e para o uso único foi de R$133,23 ao mês (R$ 0,29 por sessão). O custo indireto não apresentou diferença estatística comparando o reuso e uso único do dialisador (p= 0,463). Conclusão: O reuso do dialisador esteve associado a distúrbios osteomusculares, irritação ocular e dermatoses entre os profissionais de enfermagem, além de maior uso de medicamentos. O uso único do dialisador reduziu pequenos solutos, ferritina, hematócrito, hemoglobina, e apresentou menor risco de pirogenias e bacteremias. Quanto aos custos, o reuso do dialisador obteve benefícios adicionais em relação aos custos diretos. Entretanto, para custos indiretos, o reuso não apresentou diferença em relação ao uso único. / Capillary dialyzer reuse in hemodialysis is a practice carried out in many countries, although there is no consensus about its safety and effectiveness in comparison with the single-use dialyzer. Regarding the single-use dialyzer, costs are considered a major obstacle, as is the concern with the increase in medical waste. In what concerns the risks of reuse, the exposure of the professionals to chemicals needed to carry out the process of reuse, as well as the repetitive movements involved in the dynamics of this technique stand out; added to this, there are the reduced efficiency of the membrane, the contamination of the system, cross-infections, pyrogenic reactions and bacteremia. In this sense, a study which investigates the effect of the adoption of these methods in these outcomes becomes relevant. Objectives: To compare the implications of reused dialyzer with single-use dialyzer on the health of professionals, clinical outcomes and costs of patients in hemodialysis. Methods: Longitudinal study with retrospective data collection, carried out in a Public University Hospital (January 2015 to February 2016). Participated in the study 18 nursing technicians and 34 chronic kidney patients subjected to hemodialysis in the two periods of the study (reuse and single-use periods), through catheter, fistula or graft, with blood flow of at least 300 mL/min, dialysis time set between three to four hours per session. Musculoskeletal disorders, eye irritation, skin diseases, work leave and the use of medications were considered as primary outcomes. Secondary included hemodynamics, blood volume, laboratory tests, pyrogenic reactions, bacteremia, antibiotic use, direct and indirect costs of the procedure. The project was approved by the Ethics Committee of the institution. Results: The average time of work of the 18 nursing technicians was 12±7 years. During the period of dialyzer reuse there were seven notifications. There was a rate of exposure to the use of medicines of 6.7 days for each 1,000 professionals within the period of dialyzer reuse; 1.52 days of exposure to medication for each 1,000 professionals in the period of single use of the dialyzer, (IDR = 4.4; 95% CI: 2,182-9,805); the days of work leave were similar between periods. In the 34 patients studied in the two periods, the hemodynamic and blood volume parameters were similar; there was reduction of urea after dialysis, creatinine, phosphore, ferritin, hematocrit and hemoglobin during the single use of the dialyzer; 91% less risk of pyrogenic reaction was noted in the single use of the dialyzer compared to the period of reuse (OR = 0.091; 95% CI: 0.002-0.625). There was no significant difference in the presence of bacteremia (p = 0.125); vancomycin was used empirically to treat pyrogenic reactions. For each patient on hemodialysis using the reused dialyzer, the average value was R$ 23.18 and with the single-use dialyzer, R$ 39.77 (p=0,002). The average monthly indirect cost during the period of reuse was 168,07R$ (0.37 R$ per session), and for the single-used period, R$ 133,23 per month (0.29 R$ per session). The indirect cost showed no statistical difference comparing the reuse and the single use of the dialyzer (p = 0.463). Conclusion: The reuse of the dialyzer was associated with musculoskeletal disorders, eye irritation and skin diseases among nursing professionals, in addition to more frequent use of medicines. The single use of the dialyzer reduced small solutes, ferritin, hematocrit hemoglobin, and showed lower risk of pyrogenic reactions and bacteremia. In what concerns the costs, the reuse of the dialyzer obtained additional benefits concerning the direct costs. However, for indirect costs, reuse exceeded single use values. / La reutilización del dializador capilar en hemodiálisis es una práctica realizada en muchos países, aunque no hay ningún consenso sobre su seguridad y eficacia en comparación al dializador de uso único. Con relación al uso único, se señalan los costos como un gran obstáculo, además del incremento de los residuos hospitalarios. En lo respecta a los riesgos del reuso, se señala la exposición de los profesionales a los productos químicos necesarios para la realización del proceso de reutilización, así como los movimientos repetitivos involucrados en la dinámica de esta técnica; se suma a esto la reducción de la eficiencia de la membrana, la contaminación del sistema, las infecciones cruzadas, las reacciones pirogénicas y las bacteriemias. En este sentido, estudios para investigar el efecto de la adopción de estos métodos en estos desenlaces se vuelven relevantes. Objetivos: Comparar las implicaciones del dializador reutilizado (reuso) con las del dializador de un solo uso (uso único) para la salud de los profesionales, desenlaces clínicos y costos de los pacientes en hemodiálisis. Métodos: Estudio longitudinal, con recopilación retrospectiva de datos, realizado en un Hospital Público Universitario (desde Enero 2015 hasta Febrero 2016). Se incluyeron 18 técnicos de enfermería y 34 pacientes renales crónicos sometidos a hemodiálisis en los dos periodos de estudio (periodo de reuso y periodo de uso único), a través de catéter, fístula o injerto, con flujo de sangre de por lo menos 300 ml/min y tiempo de diálisis definido entre tres y cuatro horas por sesión. Se consideraron como desenlaces primarios los trastornos osteomusculares, irritación ocular, dermatosis, alejamiento del trabajo y uso de medicaciones. Como secundarios, se consideraron la hemodinámica, volemia, exámenes de laboratorio, reacciones pirogénicas, bacteriemias, uso de antibióticos y costos directos e indirectos del procedimiento. El proyecto fue aprobado por el Comité de Ética de la institución. Resultados: El tiempo medio de trabajo de los 18 técnicos de enfermería fue de 12±7 años. Durante el periodo de reutilización del dializador, hubo siete notificaciones. Se verificó una tasa de exposición al uso de medicamentos de 6,7 días para cada 1.000 profesionales en el periodo de reuso del dializador; 1,52 días de exposición a la medicación para cada 1.000 profesionales en el periodo de uso único del dializador (RDI= 4,4; IC 95%: 2,182-9,805); los días de alejamiento fueron similares entre los periodos. En los 34 pacientes estudiados en los dos períodos, los parámetros hemodinámicos y volémicos fueron similares; hubo una reducción de urea después del diálisis, y de creatinina, fósforo, ferritina, hematocrito y hemoglobina durante el uso único del dializador; se observó un nivel de riesgo de piogenia 91% menor en el uso único del dializador, en comparación con el periodo de reuso (RC= 0,091; IC 95%: 0,002-0,625). No hubo diferencia significativa en la presencia de bacteriemias (p= 0,125); la vancomicina fue utilizada empíricamente para tratar las reacciones pirogénicas. Para cada paciente en hemodiálisis utilizando el dializador reutilizado, el valor medio fue de R$ 23,18; y con el dializador de uso único fue de 39,77 R$ (p= 0,002). El costo indirecto medio mensual durante el periodo de reuso fue de 168,00 R$ (R$ 0,37 por sesión); y para el uso único fue de R$ 133,23 al mes (R$0,29 por sesión). El costo indirecto no presentó diferencia estadística comparando el reuso y el uso único del dializador (p= 0,463). Conclusión: El reuso del dializador estuvo asociado a trastornos osteomusculares, irritación ocular y dermatosis entre los profesionales de enfermería, además de un mayor uso de medicamentos. El uso único del dializador ha reducido pequeños solutos, ferritina, hematocrito, hemoglobina, y ha presentado un riesgo menor de reacciones pirogénicas y bacteriemias. En cuanto a los costos, el reuso del dializador ha obtenido beneficios adicionales con relación a los costos directos. Sin embargo, para los costos indirectos, el reuso no ha presentado diferencia con relación al uso único.
376

Área do conhecimento e linhas de pesquisa em enfermagem: processo de cuidar nos ciclos de vida.

Jorge, Samaris Cristina 04 April 2017 (has links)
Submitted by Fabíola Silva (fabiola.silva@famerp.br) on 2018-01-03T12:19:39Z No. of bitstreams: 1 samariscjorge_dissert.pdf: 1276666 bytes, checksum: 876b7fb259802ee85f3326ddb3f22222 (MD5) / Made available in DSpace on 2018-01-03T12:19:40Z (GMT). No. of bitstreams: 1 samariscjorge_dissert.pdf: 1276666 bytes, checksum: 876b7fb259802ee85f3326ddb3f22222 (MD5) Previous issue date: 2017-04-04 / Introduction: Chronic Kidney Disease (CKD) is one of the common chronic diseases in Brazil and has one of the most expensive treatments of the SUS, because it is a silent disease that it is important to identify the disease in its initial stage. Risk groups may assist in the identification of these patients. Hypertension (HA) and Diabetes Melitus (DM) are major causes of CKD. Currently it is estimated that approximately 50 to 70% of Brazilians die with CKD without any type of treatment. In Brazil, 45,073 thousand patients are in the treatment of chronic renal disease (CKD) and of this total, 90% of patients are users of the Unified Health System.. Objective: The objectives of this study were to characterize patients regarding sociodemographic and clinical variables in dialysis treatment for more than six months and to identify the clinical outcomes of these patients after starting treatment. Methodology: a descriptive study of electronic medical records, a retrospective, quantitative cohort study of patients with CKD in dialysis treatment in the year 2015. The statistical analysis of the quantitative variables was performed by means of specific statistical tests, considering the level of significance when p ≤0.05. Results: most were male (55.79%), married / stable union (64.56), professionally inactive (87.72%) and SUS users (69.82), had HA as the underlying disease (43.49%). The mean treatment time was 3.21 years, with a maximum time of 20.3 years. The predominant mode of dialysis was hemodialysis (91.58%). During the study period, 47 patients were transplanted (14.16%) and 44 died (13.37%). Conclusion: Chronic kidney disease is a Public Health problem, knowing the clinical outcome of patients is relevant to better care planning. / Introdução: A Doença Renal Crônica (DRC) é uma das doenças crônicas mais comuns no Brasil e possui um dos tratamentos mais caros do Sistema Único de Saúde (SUS), por ser uma doença silenciosa se torna importante identificar a doença em seu estágio inicial. Conhecer os grupos de risco podem auxiliar na identificação desses pacientes. A Hipertensão Arterial (HA) e Diabetes Melitus (DM) são causas principais da DRC. Atualmente estima-se que aproximadamente 50% a 70% dos brasileiros morrem com DRC sem nenhum tipo de tratamento. No Brasil, 45,073 mil pacientes estão em tratamento de DRC e deste total, 90 % dos pacientes são usuário do SUS. Objetivo: Caracterizar os pacientes quanto ás variáveis sociodemográficas e clínicas em tratamento a dialítico a mais de seis meses e identificar o desfecho clínico desses pacientes. Metodologia: estudo descritivo de análise de prontuário eletrônico, coorte retrospectivo, quantitativo, de pacientes com DRC em tratamento dialítico no ano de 2015. A análise estatística das variáveis quantitativas foi cálculos por meio de testes estatísticos específicos, sendo considerado o nível de significância quando p ≤ 0,05. Resultados: a maioria dos pacientes eram do sexo masculino (55,79%), casado/união estável (64,56), inativos profissionalmente (87,72%) e usuários do SUS (69,82), tinham HÁ como doença de base (43,49%). O tempo de tratamento médio foi de 3,21 anos, e tempo máximo de 20,3 anos. A modalidade de diálise predominante foi hemodiálise (91,58%). Durante o período do estudo 47 (14,16%) pacientes foram transplantados (14,16%) e 44 (13,37%) tiveram como desfecho óbito (13,37%). Conclusão: A doença renal crônica é um problema de Saúde Pública, sendo assim conhecer as características e o desfecho clinico dos pacientes é relevante para melhor implementação e avaliação da assistência.
377

Análise dos fatores preditores de mortalidade em pacientes incidentes em hemodiálise / Predictors of mortality in incident patients undergoing hemodialysis

Magalhães, Luciene Pereira 18 February 2016 (has links)
Introdução: A doença renal crônica afeta de 10 a 15 % da população adulta mundial e a piora da função renal, se associa com várias complicações, tais como: desnutrição, inflamação, doenças cardiovasculares e distúrbios do metabolismo mineral. A mortalidade desses pacientes é elevada sendo de 6 a 8 vezes maior que a de indivíduos saudáveis. Cerca de 22% dos pacientes incidentes, ou seja, no primeiro ano de diálise, vão a óbito. O objetivo do presente estudo foi avaliar as características clínicas, laboratoriais de pacientes incidentes em diálise além de identificar fatores de risco que contribuíssem para a mortalidade desses pacientes. Métodos: Estudamos 424 pacientes com sinais e sintomas de uremia e indicação de tratamento dialítico admitidos no serviço de emergência do Hospital das Clínicas entre Janeiro de 2006 e Dezembro de 2012. O tempo de acompanhamento foi de um ano. Analisamos os parâmetros clínicos, tipo de via de acesso para hemodiálise, fatores de risco ligados a doenças cardiovasculares e as alterações do metabolismo mineral bem como eventos clínicos ocorridos durante o seguimento. Avaliamos a sobrevida e os fatores que influenciaram a sobrevida dos pacientes, pela curva de Kaplan-Meier e análise de regressão de Cox, respectivamente. Resultados: A média de idade foi de 50±18 anos, 58,7% eram homens e 69,1% brancos. Hipertensão arterial foi a principal etiologia da doença renal primária (31,8%) seguida de DM (29,5%). Os principais fatores de risco encontrados foram tabagismo (19,6%), dislipidemia (48,8%), doenças cardiovasculares (41%) e na admissão a maioria dos pacientes não tinha acesso vascular para hemodiálise (89,4%). Os resultados dos exames laboratoriais revelaram que a maioria dos pacientes estava anêmico (83,7%), com níveis de PCR elevados (79,9%). Os distúrbios do metabolismo mineral como hipocalcemia, hiperfosfatemia, elevação dos níveis de paratormônio e diminuição dos níveis de 25(OH) vitamina D estavam presentes em praticamente todos os pacientes. Ao término de um ano, 60 pacientes faleceram (14,1%). Esses pacientes eram significativamente mais idosos, apresentavam sinais de insuficiência cardíaca congestiva, de desnutrição, de inflamação, níveis reduzidos de 25 (OH) vitamina D, desenvolveram maior número de infecções e não tinham acesso vascular definitivo para hemodiálise. Conclusões: A avaliação conjunta de parâmetros clínicos, laboratoriais e dos fatores de risco revelou que a idade mais avançada, presença de insuficiência cardíaca congestiva, desnutrição, inflamação, deficiência de vitamina D e a falta de via de acesso para hemodiálise foram fatores preditores de mortalidade em pacientes incidentes em hemodiálise / Introduction: Chronic kidney disease affects 10-15% of the world adult population, and the worsening of renal function is associated with several complications, such as malnutrition, inflammation, cardiovascular diseases and disorders of mineral metabolism. Mortality of those patients is high and 6 to 8 times higher than that of healthy individuals. About 22% of incident patients, that is, during the first year of dialysis, will die. The aim of this study was to evaluate the clinical and laboratory characteristics of incident dialysis patients and identify risk factors that contribute to the mortality of these patients. Methods: We studied 424 patients with signs and symptoms of uremia and dialysis indication admitted to the emergency service at Hospital das Clínicas between January 2006 and December 2012. Follow-up time was one year. We analyzed the clinical parameters, type of hemodialysis access road, risk factors linked to cardiovascular diseases and changes in mineral metabolism as well as clinical events occurred during follow-up. We evaluated survival and the factors that influenced patient survival by Kaplan-Meier curves and Cox regression analysis respectively. Results: Mean age was 50 ± 18 years old; 58.7% were males and 69.1% were white. Hypertension was the main cause of primary kidney disease (31.8%) followed by DM (29.5%). Major risk factors found were smoking (19.6%), dyslipidemia (48.8%), cardiovascular disease (41%), and upon admission most patients had no vascular access for hemodialysis (89.4%). Results of laboratory tests showed that most patients were anemic (83.7%), with high CRP levels (79.9%). Disturbances of mineral metabolism such as hypocalcemia, hyperphosphatemia, elevated parathyroid hormone levels and decreased levels of 25(OH) vitamin D were present in almost all patients. At the end of a year, 60 patients died (14.1%). These patients were significantly older, had signs of congestive heart failure, malnutrition, inflammation, low levels of 25(OH) vitamin D, developed greater number of infections and had no definitive vascular access for hemodialysis. Conclusions: The joint evaluation of clinical and laboratory parameters and risk factors revealed that older age, presence of congestive heart failure, malnutrition, inflammation, vitamin D deficiency and lack of hemodialysis access road were predictors of mortality in incident patients undergoing hemodialysis
378

Sistemas de análises químicas em fluxo explorando mecanismos de re-alimentação, calibração multivariada e outras abordagens para melhoria em desempenho / Flow systems exploiting feed-back mechanisms, multivariate calibration and other strategies for improving the analytical performance

Paula Regina Fortes 30 June 2010 (has links)
Estudos foram conduzidos relativamente ao desempenho dos sistemas de análises em fluxo quando configurados como sistemas inteligentes, associados às técnicas de calibração multivariada ou empregando nanocristais como sensibilizadores. Ainda, melhorias relacionadas às modificações dos fluxos foram avaliadas, especialmente no que se refere à diálise em linha. Neste sentido, foi proposta uma nova estratégia para implementar determinações simultâneas de ferro e vanádio em ligas metálicas envolvendo cinética diferencial. O método baseava-se nas diferentes influências exercidas por Fe2+ e por V4+ na taxa de oxidação de íons iodeto por íons Cr6+ sob condições ácidas. Três diferentes alíquotas de amostra eram inseridas em um fluxo transportador / reagente de KI, confluindo posteriormente com um fluxo de K2Cr2O7. A sobreposição entre as três zonas de amostra estabelecidas resultava em uma zona de amostra complexa com diversos valores de absorbância. Medidas realizadas nos pontos de máximos e minímos do sinal registrado eram mais precisas e continham informações acerca dos diferentes estágios de desenvolvimento da reação e de diferentes condições de concentrações. Em outra estratégia, um sistema MPFS inteligente foi proposto para a determinação turbidimétrica sequencial de sulfato e cloreto em águas naturais. Ambos os métodos foram implementados no mesmo módulo de análises, proporcionando facilidades relativas ao: preparo de amostra em linha; adição de íons sulfato ou cloreto ao meio reacional para melhoria das condições de supersaturação; decisão em tempo real acerca da necessidade ou não da próxima análise. Inicialmente, determinava-se a concentração de cloreto presente na amostra, e este resultado era comparado com um valor pré-determinado. Se este fosse superior, a amostra era analisada novamente visando à determinação de sulfato. Caso contrário, uma nova amostra era analisada. A estratégia resultou em aumento da velocidade analítica e em boas figuras de mérito analítico. Estudos relativos à natureza do fluxo foram conduzidos avaliando-se o desempenho dos fluxos pulsados provenientes de bombas solenóide em relação à eficiência do transporte de massas, dispersão da zona de amostra relacionada com a mudança de sentido do fluxo e eficiência do processo de diálise quando comparados aos fluxos tipicamente laminares. Embora fosse observada a presença de vórtices, o número de Reynolds experimentalmente obtido demonstrou que o fluxo resultante não era turbulento. Porém seu perfil exibia características de mescla turbulenta, melhorando assim o desempenho relativo ao transporte de massas e redução da dispersão da zona de amostra. Entretanto, beneficios relativos a melhorias no processo de diálise foram ausentes devido provavelmente à alta pressão exercida dentre da câmara de diálise, com consequente deformação dos poros da membrana. Nestas situações, um sistema de análises híbrido (com fluxo laminar e mescla turbulenta) seria fortemente recomendado. Finalmente, a implementação de nanocristais quantum dots (QDs) como sensibilizadores em um sistema MPFS envolvendo reação quimioluminescente foi proposta para a determinação de glipizida e gliclazida em formulaçoes farmacêuticas. O método fundamentava-se na oxidação dos íons S2- por Ce4+ em meio ácido. Na presença dos analitos, a intensidade da radiação emitida era inibida. A influência do diâmetro médio dos nanocristais foi avaliada, e os critérios utilizados para o dimensionamento do sistema foram a repetibilidade, a reprodutibilidade e a sensibilidade analítica. Os analitos foram quantificados no mesmo módulo de análises, e boas figuras de mérito analítico foram verificadas. Os resultados obtidos se apresentaram concordantes com aqueles obtidos pela Farmacopéia Britânica / Studies focusing on performance of intelligent analytical flow systems, association with multivariate calibration or use of nanocrystals as sensitizers were carried out. Moreover, improvements related to modifications in flow pattern were evaluated with emphasis to in-line dialysis. To this end, a strategy for implementing simultaneous determinations of iron and vanadium in alloys relying on differential kinetics was proposed. The method was based on the influence of Fe2+ and V4+ on the rate of iodide oxidation by Cr6+ under acidic conditions. Three different plugs of the sample were sequentially inserted into an acidic KI reagent carrier stream, and a confluent K2Cr2O7 solution was added downstream. Overlap between the established plugs led to a complex sample zone with several regions of maximal and minimal absorbance values. Measurements performed on these regions were more precise and revealed the different degrees of reaction development. In another strategy, an intelligent MPFS was proposed for sequential turbidimetric determination of sulphate and chloride in natural waters. Both methods were implemented in the same manifold, providing facilities for: in-line sample cleanup; addition of low amounts of sulphate or chloride ions to the reaction medium for improving supersaturation conditions and real-time decision on the need for next assay. The sample was initially run for chloride determination, and the analytical signal was compared with a preset value. If higher, the sample was run again, now for sulphate determination. Otherwise, next sample was assayed. The strategy led to an increased sample throughput and good analytical figures of merit. Studies focusing on the flow pattern were carried out aiming at the evaluation of the influence of the pulsed flows delivered by solenoid pumps in relation to the efficiency of mass transfer, dispersion related to changes in flow direction of the sample zone and dialysis process as compared with typical laminar flow. Although the establishment of vortices were noted, the experimentally obtained Reynolds number showed that a turbulent flow was not established. Its pattern exhibited characteristics which improved the performance due to the enhanced radial mass transport inherent in turbulent mixing. Comparatively to laminar flow, beneficial aspects were noted in relation to sample dispersion and mass transfer. In relation to dialysis efficiency however process the benefits were not noted probably due to the high pressure inside the dialysis chamber, with consequent membrane pore deformation. In this situation, a hybrid flow analysis system (with laminar flow and turbulent mixing) might be recommended. Implementation of quantum dots nanocrystals (QDs NC) as sensitizers in a MPFS with chemiluminometric detection was proposed for the determinations of gliclazide and glipizide in pharmaceutical formulations. The method relied on the oxidation of sulphite by Ce4+ in acidic medium and, in the presence of the analytes, the emitted radiation of the Ce4+-SO3 2--CdTe QDs system was inhibited. Influence of crystal size was investigated, and the criteria for system optimization were the analytical repeatability, reproducibility and sensitivity. Both analytes were quantified in the same manifold, resulting in good analytical figures of merit. The results were in fairly good agreement with those obtained by the British Pharmacopoeia reference method
379

Associação entre carga ácida da dieta e bicarbonato sérico em portadores de doença renal crônica / Association between dietary acid load and serum bicarbonate in patients with chronic kidney disease

Angeloco, Larissa Rodrigues Neto 15 December 2017 (has links)
A acidose metabólica é um achado comum em pacientes portadores de Doença Renal Crônica (DRC). Acredita-se que a dieta pode afetar o equilíbrio ácidobase do corpo por meio do fornecimento de precursores ácidos ou de base. No entanto, os resultados inconclusivos apontados na literatura indicam que ainda são necessários estudos bem delineados para comprovar a existência dessa associação. O principal objetivo desse estudo foi determinar o potencial de carga ácida renal (PRAL) proveniente da dieta e avaliar a sua associação com o bicarbonato sérico (HCO3) em pacientes com DRC enquanto em suas dietas habituais. Associações do HCO3 com o gasto energético de repouso (GER) e com oxidações proteicas e lipícas também foram estudadas. Trata-se de um estudo transversal realizado com 100 pacientes distribuídos igualmente nos estágios 3 e 4 da DRC entre 20 e 69 anos. Avaliação do estado nutricional foi feita por meio da antropometria, registro alimentar e exames bioquímicos, o qual incluiu os produtos proteicos de oxidação avançada e os isoprostanos. O HCO3 foi determinado por meio da gasometria venosa. GER foi medido pela calorimetria indireta. O PRAL foi determinado por meio do registro alimentar usando um algoritmo que inclui dados dietéticos da ingestão de proteína, fósforo, magnésio, cálcio e potássio descritos por Remer e Manz (1995). Também foi feita a diferenciação no consumo de proteína animal e vegetal. A análise dos resultados foi feita em quartis de HCO3 para as variáveis GER e parâmetros de oxidação, o restante das análises foram feitas por quartis de PRAL. Para comparação das variações médias dos quartis foi utilizado o teste one-way ANOVA. A associação entre a estimativa do PRAL e o HCO3 foi avaliada por modelos de regressão linear ajustados. A maior parte dos nossos pacientes portadores de DRC encontravam-se com excesso de peso associado a um aumento da circunferência abdominal e da porcentagem de gordura corporal. A mediana do PRAL foi de 6,8 mEq/dia com uma variação entre -24 a 52 mEq/dia. O PRAL mais elevado foi associado com o HCO3 mais baixo de uma forma graduada (p < 0.02). Encontramos uma diferença de 2,07 mmol/L no HCO3 entre o primeiro e o último quartil, sendo o valor do último quartil de PRAL menor em relação ao primeiro. A proteína animal apresentou uma correlação inversa com o bicarbonato sérico. O GER e os marcadores de oxidação lipíca e proteica não apresentaram associações com os níveis de HCO3. Esses resultados reforçam a possibilidade de que dietas com alto teor de carga ácida podem desempenhar um papel relevante no equilíbrio ácidobase em pacientes portadores de DRC, além de consolidar o uso da carga ácida da dieta como uma abordagem diferencial e complementar às outras estratégias no tratamento dietético da DRC. / Metabolic acidosis is a common complication in patients with chronic kidney disease (CKD). Acid-inducing diets are believed to impact on acid-base balance. However, well-designed studies are still needed to prove the association between dietary acid load and serum bicarbonate. The main aim of this study was to calculate the potential renal acid load (PRAL) of selected, frequently consumed foods and to evaluate its association with serum bicarbonate (HCO3) in patients with CKD. Associations of HCO3 with resting energy expenditure (REE) and with protein and lipid oxidation were also studied. It is a cross-sectional study with 100 patients equally distributed in stages 3 and 4 of CKD between 20 and 69 years. Nutritional status was assessed by anthropometric measurements, 3-day food recall, biochemical analysis including advanced oxidation protein products and isoprostanes. Venous blood gases was used to measure HCO3. GER was measured by indirect calorimetry. PRAL was determined by food record using an algorithm that includes protein, phosphorus, magnesium, calcium and potassium intake described by Remer and Manz (1995). Dietary intake of animal and vegetable protein were also evaluate. For analysis, we used quartiles of HCO3 for GER and oxidation parameters and for the others variables we used quartilhes of PRAL. ANOVA one-way test was used to compare the mean of the quartiles. The association between PRAL and HCO3 was assessed by linear regression models. Most of the patients were overweight with increased waist circumference and body fat. The median PRAL was 6.8 mEq/day with a variation between -24 to 52 mEq/day. Higher PRAL was associated with lower serum bicarbonate in a graded fashion (P trend 0.02). Serum bicarbonate was 2.07 mEq/L lower among those in the highest compared with the lowest quartile of PRAL. Animal protein was inversely correlated with serum bicarbonate. REE and lipid and protein oxidation markers showed no association with HCO3 levels. These results reinforce the possibility that diets with high dietary acid load may play a relevant role in the acid-base balance in CKD patients. In addition to consolidating the use of PRAL as a differential and complementary approach to other strategies in the nutritional treatment of CKD.
380

Riscos ocupacionais para a equipe de enfermagem que trabalha em hemodiálise

Hoefel, Heloisa Helena Karnas January 2012 (has links)
Este estudo tem como objetivo analisar riscos ocupacionais, aos quais a enfermagem está exposta no cuidado em hemodiálise. Defende-se a tese de que medidas de segurança são negligenciadas para os riscos ocupacionais que não são vistos ou sentidos. A investigação foi composta de dois momentos sendo o primeiro a análise da ocorrência de riscos no reprocessamento de sistemas de hemodiálise por inquérito recordatório. Quatro enfermeiras e oito técnicos enfermagem do hospital-escola responderam ao questionário relatando 42 riscos profissionais identificados: 29 (70%) com o participante e 13 (30%) com colegas. A partir destes achados, aprofundou-se o tema riscos em hemodiálise. Em uma segunda fase, qualitativa, optou-se pela técnica de Grupo Focal (GF), utilizando temas emergentes da fase anterior como disparadores dos debates. Dois GF (um com três enfermeiras, outro com sete técnicos) com duas sessões cada e uma terceira integrada foram realizadas. As sessões, com duração média, 60 minutos foram gravadas em áudio. Os debates contemplaram os temas referidos na primeira fase e outros levantados pelos participantes. Foi utilizada a Análise de Conteúdo de Bardin para os resultados e identificadas tres categorias: Riscos, Infraestrutura para Segurança e Organização do Trabalho. Depreendeu-se que atividades e vivências no cuidado da equipe de enfermagem, que geravam desconforto físico ou psíquico, eram identificadas por visão, olfato e sensibilidade dolorosa as quais preponderaram como fatores de risco. As inadequações estruturais e de processos causam sofrimento aos profissionais. Erros são cometidos, regras são violadas e circunstâncias de risco são assumidas em acordos tácitos a fim de reduzir o sofrimento e com o intuito de melhorar as condições de trabalho. A reação grupal leva à criação de estratégias defensivas coletivas que contornam as situações de risco e resolvem problemas momentaneamente enquanto soluções definitivas são aguardadas. A tese proposta para esta investigação foi confirmada. Sugere-se a implantação de um sistema de auditoria interna para identificar falhas e a resiliência dos processos implantados. / The occupational risks to which the nursing staff is exposed in hemodialysis care is the goal of this research with two phases. It supports the thesis that security measures are neglected to the occupational risks that are not seen or felt. Answers form about risks in the reprocessing of hemodialysis systems was the quantitative phase. Four nurses and eight nursing technicians in a teaching hospital answered to the questions. There were 42 cases considered occupational hazards during the reprocessing of dialyzers. Of the 42, 29 (70%) occurred with the participant and 13 (30%) with colleagues. Based on the findings it was identified the need to deepen the subject risks in hemodialysis. In a second phase, qualitative, we opted for Focus Group (FG) technique. Themes emerged from the previous phase was triggers of the discussions. There were 2 FG: one with three nurses participants, one FG with seven technicians. There were two sessions for each group and a third with both FG. The material was analyzed by the Bardin method in three categories: Risks, Grants / Infrastructure for Security and Labour Organization. It appeared that the activities and experiences in the care of the team that generated physical or psychological discomfort, which could be identified by sight, smell, pain sensitivity predominated in identifying risks. The causes, processes and structural lacks cause suffering to the professionals. Mistakes are made, rules are violated and circumstances of risk are perpetuated in tacit agreements between the participants of the group to reduce the suffering thinking of improving working conditions. The group reaction leads to an effective improvement of risk situations that solves momentarily definitive solutions are expected. The proposal thesis that risks are more related when risks are sight, smell and have pain is confirmed. It is suggested the establishment of an internal audit system to identify gaps and resilience of the implemented processes. / Analizar los riesgos profesionales a los que el personal de enfermería está expuesto en la atención de hemodiálisis es el objetivo de esta investigación. La tesis defendida es que las medidas de seguridad se descuidan cuando los riesgos laborales no se ven o no se sienten. El análisis de la ocurrencia de riesgos en el reprocesamiento de los sistemas de hemodiálisis en inquerito recordatório fue la fase cuantitativa. Cuatro enfermeras y ocho técnicos de enfermería en un hospital universitario han respondido al cuestionario. Fueron relatados 42 casos considerados riesgos laborales durante el reprocesamiento de los dializadores. De los 42, 29 (70%) se produjo con el participante y el 13 (30%) con sus colegas. Los resultados trajeron la necesidad de profundizar el tema de los riesgos en hemodiálisis. En la segunda fase, cualitativa, se optó por la técnica de grupos focales (GF) con los temas emergentes de la fase anterior como disparadores de los debates. Hubo dos GF (uno con tres enfermeras y uno con siete técnicos) con dos encuentros cada uno y un tercero encuentro con los dos grupos. Se contempló los temas que figuran en la primera fase y otros planteados por los participantes en las sesiones. El material fue analizado por el método de Bardin y identificadas tres categorías: Riesgo, Infraestructura para la Seguridad y Organización del Trabajo. Las actividades y experiencias en el cuidado del equipo que generaron malestar físico o psicológico, que pueden ser identificadas por la vista, ó por el olfato y la sensibilidad al dolor predominaron en la identificación de riesgos. Las causas, los procesos y las deficiencias estructurales causan sufrimiento a los profesionales. Se cometen errores, se violan las reglas y las circunstancias de riesgo son asumidas en acuerdos tácitos entre los participantes del grupo para reducir el sufrimiento y mejorar de las condiciones de trabajo. La reacción del grupo conduce a creación de estratégias defensivas colectivas que eluden las situaciones de riesgo momentáneamente enquanto aguardan soluciones definitivas. La tesis propuesta para investigación se confirmó. Se sugiere el establecimiento de un sistema de auditoría interna para identificar las fallas posibles en el proceso de trabajo y la resiliencia a los procesos que tendrán sido implementados.

Page generated in 0.0373 seconds