Spelling suggestions: "subject:"electrocardiography ambulatory"" "subject:"electrocardiographyc ambulatory""
1 |
Blood pressure, blood pressure variability and myocardial ischemia : studies in patients with peripheral arterial disease and matched control subjects /Svensson, Per, January 2004 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2004. / Härtill 5 uppsatser.
|
2 |
A practical bedsheet system for the non-contact and continuous monitoring of heart electric activities.January 2008 (has links)
Wu, Kin Fai. / Thesis (M.Phil.)--Chinese University of Hong Kong, 2008. / Includes bibliographical references (leaves 88-91). / Abstracts in English and Chinese. / Abstract --- p.i / 槪要 --- p.ii / Acknowledgements --- p.iii / Table of Contents --- p.iv / List of Figures --- p.vi / List of Tables --- p.x / Chapter Chapter 1 --- Introduction --- p.1 / Chapter 1.1 --- Motivation --- p.1 / Chapter 1.2 --- Outline of the Proposed Design --- p.2 / Chapter 1.3 --- Purposes of the Present Study --- p.2 / Chapter Chapter 2 --- Background and Literature Review --- p.4 / Chapter 2.1 --- Electrocardiogram --- p.4 / Chapter 2.2 --- Conventional ECG Measurement --- p.7 / Chapter 2.3 --- Heart Rate --- p.8 / Chapter 2.4 --- Heart Rate Variability --- p.9 / Chapter 2.5 --- Capacitive Sensing --- p.11 / Chapter 2.6 --- Review of ECG Monitoring System by Capacitive Sensing On a Sleeping Bed --- p.14 / Chapter Chapter 3 --- System Design and Implementation --- p.17 / Chapter 3.1 --- Hardware --- p.17 / Chapter 3.1.1 --- Bedsheet Sensor --- p.17 / Chapter 3.1.2 --- Pre-amplifier --- p.21 / Chapter 3.1.3 --- Measuring Device --- p.30 / Chapter 3.1.4 --- Power Supply & PCB Layout --- p.49 / Chapter 3.2 --- Software --- p.52 / Chapter 3.2.1 --- Detection of R Waves --- p.52 / Chapter 3.2.2 --- Tracking of HR & Mean RR Intervals --- p.55 / Chapter 3.2.3 --- Estimation of Signal-to-Noise Ratios --- p.56 / Chapter Chapter 4 --- Preliminary Tests on the Functionality of the Proposed System --- p.57 / Chapter 4.1 --- Test I - Test on the Arrangement of Electrodes --- p.57 / Chapter 4.1.1 --- Methods --- p.57 / Chapter 4.1.2 --- Results --- p.60 / Chapter 4.2 --- Test II - Test on the ECG Measurement of Subjects in Different Sleeping Postures --- p.64 / Chapter 4.2.1 --- Methods --- p.64 / Chapter 4.2.2 --- Results --- p.65 / Chapter Chapter 5 --- Experiments on the Performance of Continuous Monitoring of ECG and HR --- p.69 / Chapter 5.1 --- Experiment I - Experiment on the Reliability of the Proposed System for Continuous Monitoring of ECG and HR on Thirty Subjects --- p.69 / Chapter 5.1.1 --- Methods --- p.70 / Chapter 5.1.2 --- Results --- p.70 / Chapter 5.2 --- Experiment II - Experiment on the Feasibility of the Proposed System for Continuous Monitoring of ECG and HR on a Subject During an Eight-hour Sleep --- p.75 / Chapter 5.2.1 --- Materials --- p.76 / Chapter 5.2.2 --- Methods --- p.76 / Chapter 5.2.3 --- Results --- p.77 / Chapter Chapter 6 --- Discussions --- p.81 / Chapter 6.1 --- Selection of the Passband of the Proposed Circuit --- p.81 / Chapter 6.2 --- Arrangement of Electrodes on the Bedsheet --- p.82 / Chapter 6.3 --- Practical Design of Electrodes --- p.83 / Chapter 6.4 --- Performance of Continuous Monitoring of HR by Using the Proposed System --- p.84 / Chapter Chapter 7 --- Conclusion --- p.86 / References --- p.88
|
3 |
Eventos arrítmicos em pacientes com canalopatias cardíacas submetidos à anestesia local odontológica: estudo piloto randomizado / Arrhythmic events in patients with cardiac channelopathies subjected to local dental anesthesia: a randomized pilot studyOliveira, Ana Carolina Guimarães 14 May 2019 (has links)
Introdução: Distúrbios dos canais iônicos cardíacos potencialmente letais, como a síndrome de Brugada (SBr), a síndrome do QT longo congênito (SQTL) e a taquicardia ventricular polimórfica catecolaminérgica (TVPC) podem ser responsáveis por pelo menos um terço do total de casos de morte súbita que permanecem inexplicados. Estes pacientes, por vezes, não obtêm tratamento odontológico e analgesia adequados devido à falta de informações na literatura em relação à dose e tipo de anestésico local recomendado, e ao risco potencial de eventos cardíacos ameaçadores à vida e instabilidade hemodinâmica. Métodos: Trata-se de um estudo piloto, randomizado, duplo-cego e cruzado com portadores de canalopatias cardíacas submetidos a tratamento odontológico restaurador em duas sessões, realizadas com intervalo mínimo de sete dias (wash-out) entre ambas, sendo o paciente seu próprio controle. Na primeira sessão, por randomização, o paciente recebeu uma das soluções anestésicas: lidocaína 2% sem vasoconstritor (LSA) ou lidocaína 2% com adrenalina 1:100.000 (LCA), originando duas condições: sem adrenalina e com adrenalina; na segunda sessão recebeu o outro anestésico. Todos foram monitorados com Holter por 28 horas, contadas a partir de uma hora antes do procedimento, nas duas sessões do estudo. Durante o atendimento odontológico, foram feitos registros pontuais em três momentos por meio de eletrocardiograma de 12 derivações, esfigmomanômetro digital para pressão arterial e escala de mensuração da ansiedade. Resultados: Sessenta e dois procedimentos restauradores foram realizados em 31 pacientes: 16 (51,6%) tinham SQTL, 12 (38,7%) SBr e três (9,7%) TVPC, dentre os quais 12 (38,7%) eram portadores de cardiodesfibrilador implantável. A idade média dos pacientes foi 45,2+15,8 anos, sendo 21 (67,7%) do sexo feminino. Os valores médios da frequência cardíaca máxima se mostraram aumentados com o uso de LCA no período da anestesia (84,4 x 80,4 bpm; p=0,005) com diferença estatisticamente significante entre as duas condições, assim como o QTc em pacientes com SQTL (465,4 x 450,1; p=0,009). Valores de pressão arterial e mensuração da ansiedade não mostraram diferença estatisticamente significante. Não foram observadas arritmias ventriculares ameaçadoras à vida durante os procedimentos. Conclusões: O uso da anestesia local com lidocaína, independente do uso de vasoconstritor, não resultou em arritmias ameaçadoras à vida e foi considerado seguro nos pacientes selecionados. Estes resultados preliminares devem ser confirmados em uma população maior, em um estudo multicêntrico / Background: Ion channel disorders, such as Brugada syndrome (BS), long QT syndrome (LQTS), and catecholaminergic polymorphic ventricular tachycardia (CPVT), may account for at least one-third of unexplained sudden cardiac deaths. These patients often do not receive adequate dental treatment and analgesia owing to the lack of information in the literature regarding the dose and type of local anesthetic recommended, and due to the potential risk of life-threatening cardiac events. Methods: This is a randomized, double-blind pilot trial in patients with cardiac CCh underwent to restorative dental treatment in two sessions, with a wash-out period of 7 days (crossover trial). In the first session, by randomization, the patient received one of the anesthetic solutions: 2% lidocaine without vasoconstrictor (LSA) or 2% lidocaine with epinephrine 1: 100,000 (LCA), making two conditions: without epinephrine and with epinephrine; and in the second session received the other anesthetic. Twenty-eight-hour Holter monitoring was performed in all patients, initiated one hour before the procedure, in the two study sessions. During the dental treatment, additional specific monitoring including 12-lead electrocardiography (ECG), digital sphygmomanometry and anxiety scale assessments was also applied at three time points. Results: Sixty-two dental procedures were performed in 31 patients with CCh: 16 (51.6%) had LQTS, 12 (38.7%) had BS and three (9.7%) had CPVT; 12 (38.7%) patients had an implantable defibrillator. The mean age was 45.2+15.8 years, and 21 (67.7%) patients were female. The maximum heart rate was increased after the use of epinephrine during the anesthesia period (84,4 x 80,4 bpm, p=0.005), as well the corrected QT in LQTS patients (465,4 x 450,1; p=0,009). Blood pressure and anxiety measurements showed no statistically significant differences. No life-threatening arrhythmias occurred during the dental treatment. Conclusions: The use of local dental anesthesia with lidocaine, regardless of the use of a vasoconstrictor, did not result in life-threatening arrhythmias and was considered safe in these selected patients with channelopathies. These preliminary findings need to be confirmed in a larger population study, in a multicenter study
|
4 |
Importância do eletrocardiograma de repouso, de alta resolução e do Holter de 24 horas em pacientes com miocárdio não compacto: relação com os achados do ecocardiograma e ressonância magnética cardíaca / Importance of resting electrocardiogram, high resolution and 24-hour Holter in patients with myocardial noncompaction: relation with echocardiogram findings, and cardiac magnetic resonanceCorrêa, Renata dos Santos 17 August 2018 (has links)
INTRODUÇÃO: A miocardiopatia não compactada (MNC) é caracterizada pela formação de trabéculas miocárdicas proeminentes com recessos intertrabeculares profundos no ventrículo esquerdo (VE). Os pacientes podem apresentar insuficiência cardíaca, tromboembolismo e/ou arritmia. Os avanços de métodos diagnósticos têm permitido um maior reconhecimento desta doença. Assim, o objetivo deste estudo foi analisar os achados do eletrocardiograma (ECG), Holter de 24hs e eletrocardiograma de alta resolução (ECGAR), e sua relação com ecocardiograma (ECO) transtorácico e pela ressonância magnética cardíaca (RMC) em pacientes com MNC. MÉTODOS: Foram analisados pacientes com diagnóstico de MNC pelo ECO e/ou RMC, em acompanhamento ambulatorial em nossa instituição. Esses pacientes foram submetidos à avaliação clínica, ECG de 12 derivações, Holter de 24hs e ECGAR. Os dados do ECG foram analisados por dois observadores e comparados com o grupo controle, saudáveis. RESULTADOS: Sessenta e seis pacientes com MNC (45,1 ± 17,3 anos, 56,1% do sexo masculino), e vinte controles (52,6 ± 19,2 anos, 30,0% do sexo masculino), foram incluídos neste estudo. Os pacientes apresentaram fração de ejeção do VE pelo ECO de 41,2 ± 9,4%, e pela RMC de 40,8 ± 16,9%. Os achados eletrocardiográficos mais frequentes foram alteração da repolarização ventricular (65,2%), sobrecarga do VE (24,2%) e extrassístoles ventriculares (EEVV) (19,7%); com índice de concordância interobservadores alto, entre todas as variáveis (p < 0,001), exceto sobrecarga biventricular. O grupo com fração de ejeção reduzida apresentou um maior número de casos com sobrecarga de átrio esquerdo e maior duração do QRS em relação ao grupo sem disfunção (p= 0,020; p=0,008, respectivamente). O grupo que apresentou realce tardio tem maior número de pacientes com bloqueio de ramo esquerdo/bloqueio divisional anterossuperior esquerdo e maior duração do QRS quando comparado ao grupo sem realce (p= 0,034; p=0,035, respectivamente). No Holter de 24 horas, 4,4% apresentou ritmo de fibrilação atrial e 18,2% taquicardia ventricular não sustentada (TVNS) relacionada com os diâmetros de átrio e ventrículos esquerdos pelo ECO (P=0,008, P=0,0048, respectivamente); houve correlação entre o aumento do volume diastólico final pela RMC e intervalo PR (r=0,414; p=0,007), EEVV (r=0,426; p < 0,005) e intervalo QRS (r=0,564; p < 0,001). Além disso, o realce tardio apresentou relação com TVNS (p=0,009), extrassístole atrial (p=0,002), EEVV (p=0,004), duração do QRS (p=0,002), pela análise do Holter de 24hs. O ECGAR estava alterado em 10,6% dos pacientes, sendo que destes 12,2% apresentavam disfunção ventricular. Houve correlação entre dilatação de cavidades esquerdas pelo ECO, com duração do QRS filtrado e Standard (STD) (r=0,577; p < 0,001), e relação entre QRS filtrado e realce tardio (p <0,001) e dilatação ventricular pela RMC com QRS filtrado e STD (p < 0,001 para ambos). Os pacientes que foram a óbito, no período de seguimento de 4 anos, tinham uma frequência maior de TVNS (p=0,006). CONCLUSÃO: Os pacientes com MNC apresentaram alterações significativas do ECG, ECGAR e Holter de 24hs, mais evidentes no grupo de pacientes com disfunção ventricular e realce tardio. Dessa forma, estes pacientes devem ser acompanhados mais frequentemente, pelo risco maior de desfecho clínico desfavorável ambulatory. / INTRODUCTION: Noncompacted cardiomyopathy (NCC) is characterized by the formation of prominent myocardial trabeculae with deep intertrabecular recesses in the left ventricle (LV). Patients may present with heart failure, thromboembolism and/or arrhythmia. Advances in diagnostic methods have allowed greater recognition of this disease. Thus, the aim of this study was to analyze the findings of electrocardiogram (ECG), 24-hour Holter and high resolution electrocardiogram (ECGAR), and its relationship with transthoracic echocardiogram (ECHO) and cardiac magnetic resonance imaging (MRI) in patients with MNC. METHODS: Patients with a diagnosis of NCC by ECGO and / or CMR were analyzed in an outpatient clinic at our institution. These patients underwent clinical evaluation, 12-lead ECG, 24-hour Holter, and ECGAR. ECG data were analyzed by two observers and compared to the healthy control group. RESULTS: Sixty-six patients with MNC (45.1 ± 17.3 years, 56.1% males), and twenty controls (52.6 ± 19.2 years, 30.0% males) were included in this study. The patients presented LV ejection fraction by ECHO of 41.2 ± 9.4%, and CMR of 40.8 ± 16.9%. The most frequent electrocardiographic findings were alteration of ventricular repolarization (65.2%), LV overload (24.2%) and ventricular extrasystoles (VEE) (19.7%); with a high interobserver agreement index among all variables (p < 0.001), except for biventricular overload. The group with reduced ejection fraction presented a higher number of cases with left atrial overload and longer duration of QRS compared to the group without dysfunction (p = 0.020, p = 0.008, respectively). The group that presented delayed enhancement had a higher number of patients with left bundle branch block / anterosuperior left divisional block and longer duration of the QRS when compared to the group without enhancement (p = 0.034, p = 0.035, respectively). In the 24-hour Holter, 4.4% presented atrial fibrillation and 18.2% non-sustained ventricular tachycardia (NSVT). This was related to left ventricular atrial and ventricular diameters (P = 0.008, P = 0.0048, respectively); (r = 0.414, p = 0.007), EEVV (r = 0.426, p < 0.005), and QRS interval (r = 0.564, p < 0.001) were correlated with the increase in final diastolic volume. In addition, the late enhancement was related to NSVT (p = 0.009), atrial extrasystole (p = 0.002), VLT (p = 0.004), QRS duration (p = 0.002), and 24h Holter analysis. The ECGAR was altered in 10.6% of the patients, of whom 12.2% had ventricular dysfunction. There was a correlation between left ventricular ECO dilatation with filtered QRS duration and standard (STD) (r = 0.577, p < 0.001), and the relationship between filtered QRS and late enhancement (p < 0.001) and ventricular dilation by MRI with filtered QRS and STD (p < 0.001 for both). Patients who died at the 4-year follow-up period had a higher frequency of NSVT (p = 0.006). CONCLUSION: Patients with NCC present significant ECG, ECGAR and Holter 24hs changes, most evident in the group of patients with ventricular dysfunction and late enhancement. Therefore, these patients should be monitored more frequently, due to the greater risk of unfavorable clinical outcome
|
5 |
Estudo das alterações da variabilidade da freqüência cardíaca e troponina no paciente séptico / Heart rate variability and troponin in septic patientsNogueira, Antonio Carlos 24 April 2006 (has links)
CONTEXTO: Estudos observacionais têm demonstrado alterações na variabilidade da freqüência cardíaca em pacientes em sepse, embora não exista publicação correlacionando lesão cardíaca causada pela inflamação sistêmica e redução da variabilidade da freqüência cardíaca. OBJETIVOS: Determinar, em pacientes em sepse, se a lesão cardíaca é causa das alterações da variabilidade da freqüência cardíaca e sua correlação com a mortalidade. Analisar também a associação entre evolução clínica e variabilidade da freqüência cardíaca, troponina, lesão celular à microscopia eletrônica e óptica e variáveis hemodinâmicas. MÉTODO: Estudo observacional, prospectivo, entre pacientes que desenvolveram sepse grave ou choque séptico, analisando sobrevida. Foram analisados: variabilidade da freqüência cardíca (alta e baixa freqüência, através da monitorização cardíaca contínua), dosagem dos níveis séricos de troponina, creatinofosfoquinase e creatinofosfoquinase fração MB, proteína C-reativa, alterações morfológicas e funcionais das células cardíacas por microscopia óptica e eletrônica e imunoistoquímica. Os dados hemodinâmicos foram obtidos por ecocardiograma e medida direta por cateter de artéria pulmonar. RESULTADOS: Dos 31 pacientes incluídos, 12 (38,7%) morreram durante o acompanhamento de 6 dias e 13 sobreviveram até o 28o dia (41,9%); 6 pacientes (19,4%) morreram nas primeiras 6 horas do estudo. O índice APACHE, utilizado como marcador prognóstico, foi igual nos dois grupos (27 +/- 2,6 nos sobreviventes e 26 +/- 2 nos não sobreviventes). A troponina plasmática se mostrou marcador de disfunção miocárdica na sepse (sobreviventes: 0,53 +/- 0,13 mg/ml, e não-sobreviventes: 2,31 +/- 1,01 mg/ml, p < 0,05), com informação prognostica, e se correlacionou com os piores dados hemodinâmicos do grupo de não-sobreviventes (índice de trabalho sistólico do ventrículo esquerdo no grupo de sobreviventes de 48,1 +/- 6,7 g.m/m2 e no de não-sobreviventes de 34,0 +/- 6,7 g.m/m2, p < 0,05). A variabilidade da freqüência cardíaca diminuída se correlacionou com pior prognóstico e a análise multivariada apontou a baixa freqüência cardíaca como uma variável independente para predizer alta da unidade de terapia intensiva (280 +/- 25 ms2 nos sobreviventes e 84 +/- 7,2 ms2 nos pacientes que evoluiram a óbito, freqüência mínima 129 +/- 19 ms2 e 65 +/- 9 ms2 na freqüência máxima, p < 0,05). A microscopia do coração evidenciou infiltrado inflamatório difuso e aumento do número de mitocôndrias e destruição destas organelas. CONCLUSÃO: Nossos resultados sugerem que a alteração da variabilidade da freqüência cardíaca está relacionada com a evolução para óbito, e correlaciona-se com a lesão cardíaca diagnosticada pela dosagem de troponina sérica e alteração do índice do trabalho sistólico do ventrículo esquerdo por sístole. A histologia do coração demonstrou importante lesão celular do coração, com destruição e aumento do número de mitocôndrias. / CONTEXT: Observational studies have shown alterations in the variability of heart rate in patients with sepsis, although there is not a published study showing correlation to cardiac lesion caused by systemic inflammation and reduction on the heart rate variability. OBJECTIVE: To determine, in patients in sepsis, if the cardiac lesion is caused by the alteration on the heart rate variability and access its correlation with mortality; and also, to analyze the association between clinical evolution and cardiac rate variability, plasmatic troponin, cellular lesion on electronic microscopy and optic and the patients\' hemodynamic data. METHOD: Observational study among patients that developed sepsis or septic shock, analyzing the survivors\' rate. The heart rate variability was analyzed (high and low rate through continuous cardiac monitorization), as well as plasma levels of troponin, CK, CK-MB, C-reactive protein, the morphologic alterations and of cardiac cells function, through electronic and optic microscopy and through immunohistochemistry. The hemodynamics\' data were analyzed though echocardiogram and pulmonary artery catheter. RESULTS: Among 31 patients included, 12 (38.7%) of them died during the course of 6 days and 13 (41.9%) survived until the 28th day, 6 (19.4%) died within the first 6 hours of the study. The APACHE index, used as a prognostic marker, was the same in both groups (27 +/- 2.6 in the survivor group and 26 +/- 2.0 in the non-survivors group). The plasmatic troponin became a marker in the myocardial dysfunction in sepsis (survivors 0.53 +/- 0.13 mg/ml and non-survivors 2.31 +/- 1.01 mg/ml, p < 0.05), with prognostic information, and it correlated with the worst hemodynamic parameters among non-survivors group (left ventricle systolic index was 48.1 +/-6.7 g.m/m2 in survivors and 34.0 +/- 6.7 g.m/m2 in non survivors group, p < 0.05). The decrease on the heart rate variability was correlated with the worst prognoses and analyses pointed to a low rate as an independent variable to predict the patients discharge from the intensive care unit (280 +/- 25 ms2 among survivors and 84 +/-7.2ms2 among non-survivors). The heart microscopy showed diffused inflammatory infiltration and increase in the number of mitochondrias and lesions in these organelles. CONCLUSION: Our results suggest that the alteration of the variability on the heart rate is related with the evolution to death, and correlated to cardiac lesion, evidenced through the dosage of troponin, and to alteration of the systolic workload of the left ventricle by systole. The heart histology demonstrated important cellular lesion of the heart, with a raise in number of and damage to mitochondrias.
|
6 |
Importância do eletrocardiograma de repouso, de alta resolução e do Holter de 24 horas em pacientes com miocárdio não compacto: relação com os achados do ecocardiograma e ressonância magnética cardíaca / Importance of resting electrocardiogram, high resolution and 24-hour Holter in patients with myocardial noncompaction: relation with echocardiogram findings, and cardiac magnetic resonanceRenata dos Santos Corrêa 17 August 2018 (has links)
INTRODUÇÃO: A miocardiopatia não compactada (MNC) é caracterizada pela formação de trabéculas miocárdicas proeminentes com recessos intertrabeculares profundos no ventrículo esquerdo (VE). Os pacientes podem apresentar insuficiência cardíaca, tromboembolismo e/ou arritmia. Os avanços de métodos diagnósticos têm permitido um maior reconhecimento desta doença. Assim, o objetivo deste estudo foi analisar os achados do eletrocardiograma (ECG), Holter de 24hs e eletrocardiograma de alta resolução (ECGAR), e sua relação com ecocardiograma (ECO) transtorácico e pela ressonância magnética cardíaca (RMC) em pacientes com MNC. MÉTODOS: Foram analisados pacientes com diagnóstico de MNC pelo ECO e/ou RMC, em acompanhamento ambulatorial em nossa instituição. Esses pacientes foram submetidos à avaliação clínica, ECG de 12 derivações, Holter de 24hs e ECGAR. Os dados do ECG foram analisados por dois observadores e comparados com o grupo controle, saudáveis. RESULTADOS: Sessenta e seis pacientes com MNC (45,1 ± 17,3 anos, 56,1% do sexo masculino), e vinte controles (52,6 ± 19,2 anos, 30,0% do sexo masculino), foram incluídos neste estudo. Os pacientes apresentaram fração de ejeção do VE pelo ECO de 41,2 ± 9,4%, e pela RMC de 40,8 ± 16,9%. Os achados eletrocardiográficos mais frequentes foram alteração da repolarização ventricular (65,2%), sobrecarga do VE (24,2%) e extrassístoles ventriculares (EEVV) (19,7%); com índice de concordância interobservadores alto, entre todas as variáveis (p < 0,001), exceto sobrecarga biventricular. O grupo com fração de ejeção reduzida apresentou um maior número de casos com sobrecarga de átrio esquerdo e maior duração do QRS em relação ao grupo sem disfunção (p= 0,020; p=0,008, respectivamente). O grupo que apresentou realce tardio tem maior número de pacientes com bloqueio de ramo esquerdo/bloqueio divisional anterossuperior esquerdo e maior duração do QRS quando comparado ao grupo sem realce (p= 0,034; p=0,035, respectivamente). No Holter de 24 horas, 4,4% apresentou ritmo de fibrilação atrial e 18,2% taquicardia ventricular não sustentada (TVNS) relacionada com os diâmetros de átrio e ventrículos esquerdos pelo ECO (P=0,008, P=0,0048, respectivamente); houve correlação entre o aumento do volume diastólico final pela RMC e intervalo PR (r=0,414; p=0,007), EEVV (r=0,426; p < 0,005) e intervalo QRS (r=0,564; p < 0,001). Além disso, o realce tardio apresentou relação com TVNS (p=0,009), extrassístole atrial (p=0,002), EEVV (p=0,004), duração do QRS (p=0,002), pela análise do Holter de 24hs. O ECGAR estava alterado em 10,6% dos pacientes, sendo que destes 12,2% apresentavam disfunção ventricular. Houve correlação entre dilatação de cavidades esquerdas pelo ECO, com duração do QRS filtrado e Standard (STD) (r=0,577; p < 0,001), e relação entre QRS filtrado e realce tardio (p <0,001) e dilatação ventricular pela RMC com QRS filtrado e STD (p < 0,001 para ambos). Os pacientes que foram a óbito, no período de seguimento de 4 anos, tinham uma frequência maior de TVNS (p=0,006). CONCLUSÃO: Os pacientes com MNC apresentaram alterações significativas do ECG, ECGAR e Holter de 24hs, mais evidentes no grupo de pacientes com disfunção ventricular e realce tardio. Dessa forma, estes pacientes devem ser acompanhados mais frequentemente, pelo risco maior de desfecho clínico desfavorável ambulatory. / INTRODUCTION: Noncompacted cardiomyopathy (NCC) is characterized by the formation of prominent myocardial trabeculae with deep intertrabecular recesses in the left ventricle (LV). Patients may present with heart failure, thromboembolism and/or arrhythmia. Advances in diagnostic methods have allowed greater recognition of this disease. Thus, the aim of this study was to analyze the findings of electrocardiogram (ECG), 24-hour Holter and high resolution electrocardiogram (ECGAR), and its relationship with transthoracic echocardiogram (ECHO) and cardiac magnetic resonance imaging (MRI) in patients with MNC. METHODS: Patients with a diagnosis of NCC by ECGO and / or CMR were analyzed in an outpatient clinic at our institution. These patients underwent clinical evaluation, 12-lead ECG, 24-hour Holter, and ECGAR. ECG data were analyzed by two observers and compared to the healthy control group. RESULTS: Sixty-six patients with MNC (45.1 ± 17.3 years, 56.1% males), and twenty controls (52.6 ± 19.2 years, 30.0% males) were included in this study. The patients presented LV ejection fraction by ECHO of 41.2 ± 9.4%, and CMR of 40.8 ± 16.9%. The most frequent electrocardiographic findings were alteration of ventricular repolarization (65.2%), LV overload (24.2%) and ventricular extrasystoles (VEE) (19.7%); with a high interobserver agreement index among all variables (p < 0.001), except for biventricular overload. The group with reduced ejection fraction presented a higher number of cases with left atrial overload and longer duration of QRS compared to the group without dysfunction (p = 0.020, p = 0.008, respectively). The group that presented delayed enhancement had a higher number of patients with left bundle branch block / anterosuperior left divisional block and longer duration of the QRS when compared to the group without enhancement (p = 0.034, p = 0.035, respectively). In the 24-hour Holter, 4.4% presented atrial fibrillation and 18.2% non-sustained ventricular tachycardia (NSVT). This was related to left ventricular atrial and ventricular diameters (P = 0.008, P = 0.0048, respectively); (r = 0.414, p = 0.007), EEVV (r = 0.426, p < 0.005), and QRS interval (r = 0.564, p < 0.001) were correlated with the increase in final diastolic volume. In addition, the late enhancement was related to NSVT (p = 0.009), atrial extrasystole (p = 0.002), VLT (p = 0.004), QRS duration (p = 0.002), and 24h Holter analysis. The ECGAR was altered in 10.6% of the patients, of whom 12.2% had ventricular dysfunction. There was a correlation between left ventricular ECO dilatation with filtered QRS duration and standard (STD) (r = 0.577, p < 0.001), and the relationship between filtered QRS and late enhancement (p < 0.001) and ventricular dilation by MRI with filtered QRS and STD (p < 0.001 for both). Patients who died at the 4-year follow-up period had a higher frequency of NSVT (p = 0.006). CONCLUSION: Patients with NCC present significant ECG, ECGAR and Holter 24hs changes, most evident in the group of patients with ventricular dysfunction and late enhancement. Therefore, these patients should be monitored more frequently, due to the greater risk of unfavorable clinical outcome
|
7 |
Avaliação dos fatores de risco de extrassístoles supraventriculares e ventriculares em pacientes ambulatoriais / Evaluation of risk factors of premature atrial and ventricular beats in outpatientsRibeiro, Wilma Noia 17 May 2018 (has links)
As extrassístoles são achados frequentes em pacientes ambulatoriais, o que suscita o interesse em avaliar o seu significado clínico e fatores associados. O objetivo do estudo foi investigar as variáveis relacionadas com a presença de extrassístoles identificadas em pacientes ambulatoriais selecionados ao terem recebido a indicação de eletrocardiograma de rotina na rede básica de saúde. Foi realizado estudo transversal com 407 pacientes (idade média 55,8 anos ± 12 anos, 56% mulheres) encaminhados de Unidades Básicas de Saúde para o Hospital Municipal Doutor Fernando Mauro Pires da Rocha para realização de eletrocardiograma de repouso. Os participantes foram submetidos a questionário, exame físico, exames laboratoriais, ecocardiograma e monitorização eletrocardiográfica ambulatorial de 24 horas, a qual foi empregada para categorizar a frequência de extrassístoles. Depois de análise descritiva e exploratória, a regressão logística foi utilizada para avaliar as associações entre as variáveis. Extrassístoles supraventriculares ( >= 4/hora) se relacionaram com a idade (razão de chances 1,030; intervalo de confiança 95% 1,002 - 1,059; p=0,029), níveis de peptídeos natriuréticos > 20mg/dL (razão de chances 4,489; intervalo de confiança 95% 1,918 - 10,507; p=0.0005), bloqueios intraventriculares (razão de chances 4,184; intervalo de confiança 95% 1,861 - 9,406; p=0,0005) e diâmetro de átrio esquerdo (razão de chances 1,065; intervalo de confiança 95% 1,001 - 1,134; p=0,046). Extrassístoles ventriculares ( >= 5/hora) se associaram com a idade (razão de chances 1,032; intervalo de confiança 95% 1,010 - 1,054; p=0,004), uso de bloqueadores de canais de cálcio (razão de chances 2,248; intervalo de confiança 95% 1,019 - 4,954; p=0,045), níveis de peptídeos natriuréticos > 20mg/dL (razão de chances 2,079; intervalo de confiança 95% 1,062 - 4,068; p=0,033), taxas de HDL-colesterol (razão de chances 0,971; intervalo de confiança 95% 0,951 - 0,992; p=0,007), frequência cardíaca no eletrocardiograma (razão de chances 1,019; intervalo de confiança 95% 1,001 - 1,038; p=0,041), hipertrofia ventricular esquerda (razão de chances 2,292; intervalo de confiança 95% 1,402 - 3,746; p=0,001) e fração de ejeção ventricular esquerda (razão de chances 0,938; intervalo de confiança 95% 0,900 - 0,978; p=0,002). Na população estudada, os batimentos prematuros foram achados recorrentes e de baixa densidade na eletrocardiografia dinâmica de 24 horas. Extrassístoles mais frequentes se associaram a níveis de peptídeos natriuréticos > 20mg/dL e taxas mais baixas de HDL-colesterol; além disso, foi identificada maior dilatação atrial e hipertrofia ventricular no ecocardiograma dos pacientes com esse achado, sugerindo acometimento de órgão alvo decorrente de hipertensão arterial não controlada. Portanto, a detecção de extrassístoles frequentes na monitorização eletrocardiográfica de 24 horas, em pacientes acompanhados no nível de atenção primária, reitera as recomendações dirigidas principalmente para os cuidados com os fatores de risco associados com a sua presença / Premature complexes are common findings in outpatients; thus, it is important to evaluate their clinical significance and related factors. The aim of our study was to examine the variables associated with premature beats identified in outpatients who were followed by general practitioners in a primary public healthcare setting. We performed a cross-sectional study of 407 outpatients (mean age: 55.8±12 years; 56% women) who were referred from Basic Health Units to Doctor Fernando Mauro Pires da Rocha Municipal Hospital to perform a resting 12-lead electrocardiogram for clinical follow-up. They answered a questionnaire and submitted the physical examination, fasting laboratory testing, transthoracic echocardiogram and 24-hour Holter monitoring, which were used to categorize the frequency of premature complexes. After the univariate analysis, logistic regression analyses were performed to evaluate the independent association among the variables. Premature atrial complexes ( >= 4/hour) were associated with age (odds ratio 1.030; confidence interval 95% 1.002 - 1.059; p=0.029), peptide natriuretic levels > 20mg/dL (odds ratio 4.489; confidence interval 95% 1.918 - 10.507; p=0.0005), intraventricular blocks (odds ratio 4.184; confidence interval 95% 1.861 - 9.406; p=0.0005) and left atrium diameter (odds ratio 1.065; confidence interval 95% 1.001 - 1.134; p=0.046). Premature ventricular complexes ( >= 5/hour) were associated with age (odds ratio 1.032; confidence interval 95% 1.010 - 1.054; p=0.004), the use of calcium channels blockers (odds ratio 2.248; confidence interval 95% 1.019 - 4.954; p=0.045), peptide natriuretic levels > 20mg/dL (odds ratio 2.079; confidence interval 95% 1.062 - 4.068; p=0.033), HDL-cholesterol levels (odds ratio 0.971; confidence interval 95% 0.951 - 0.992; p=0.007), heart rate (odds ratio 1.019; confidence interval 95% 1.001 - 1.038; p=0.041), left ventricle hypertrophy (odds ratio 2.292; confidence interval 95% 1.402 - 3.746; p=0.001) and left ventricle ejection fraction (odds ratio 0.938; confidence interval 95% 0.900 - 0.978; p=0.002). In our population, premature complexes were common findings on 24-hour Holter monitoring, but of low density. Frequent ectopic beats were associated with peptide natriuretic levels > 20mg/dL and lower levels of HDL-cholesterol; left atrial enlargement and ventricular hypertrophy were also identified on the echocardiograms of these patients, suggesting that target organ damage was due to uncontrolled arterial hypertension. Therefore, the identification of frequent premature complexes on 24-hour Holter monitor recording of outpatients in a primary public healthcare setting reaffirms the need for monitoring for the risk factors associated with this finding
|
8 |
Avaliação dos fatores de risco de extrassístoles supraventriculares e ventriculares em pacientes ambulatoriais / Evaluation of risk factors of premature atrial and ventricular beats in outpatientsWilma Noia Ribeiro 17 May 2018 (has links)
As extrassístoles são achados frequentes em pacientes ambulatoriais, o que suscita o interesse em avaliar o seu significado clínico e fatores associados. O objetivo do estudo foi investigar as variáveis relacionadas com a presença de extrassístoles identificadas em pacientes ambulatoriais selecionados ao terem recebido a indicação de eletrocardiograma de rotina na rede básica de saúde. Foi realizado estudo transversal com 407 pacientes (idade média 55,8 anos ± 12 anos, 56% mulheres) encaminhados de Unidades Básicas de Saúde para o Hospital Municipal Doutor Fernando Mauro Pires da Rocha para realização de eletrocardiograma de repouso. Os participantes foram submetidos a questionário, exame físico, exames laboratoriais, ecocardiograma e monitorização eletrocardiográfica ambulatorial de 24 horas, a qual foi empregada para categorizar a frequência de extrassístoles. Depois de análise descritiva e exploratória, a regressão logística foi utilizada para avaliar as associações entre as variáveis. Extrassístoles supraventriculares ( >= 4/hora) se relacionaram com a idade (razão de chances 1,030; intervalo de confiança 95% 1,002 - 1,059; p=0,029), níveis de peptídeos natriuréticos > 20mg/dL (razão de chances 4,489; intervalo de confiança 95% 1,918 - 10,507; p=0.0005), bloqueios intraventriculares (razão de chances 4,184; intervalo de confiança 95% 1,861 - 9,406; p=0,0005) e diâmetro de átrio esquerdo (razão de chances 1,065; intervalo de confiança 95% 1,001 - 1,134; p=0,046). Extrassístoles ventriculares ( >= 5/hora) se associaram com a idade (razão de chances 1,032; intervalo de confiança 95% 1,010 - 1,054; p=0,004), uso de bloqueadores de canais de cálcio (razão de chances 2,248; intervalo de confiança 95% 1,019 - 4,954; p=0,045), níveis de peptídeos natriuréticos > 20mg/dL (razão de chances 2,079; intervalo de confiança 95% 1,062 - 4,068; p=0,033), taxas de HDL-colesterol (razão de chances 0,971; intervalo de confiança 95% 0,951 - 0,992; p=0,007), frequência cardíaca no eletrocardiograma (razão de chances 1,019; intervalo de confiança 95% 1,001 - 1,038; p=0,041), hipertrofia ventricular esquerda (razão de chances 2,292; intervalo de confiança 95% 1,402 - 3,746; p=0,001) e fração de ejeção ventricular esquerda (razão de chances 0,938; intervalo de confiança 95% 0,900 - 0,978; p=0,002). Na população estudada, os batimentos prematuros foram achados recorrentes e de baixa densidade na eletrocardiografia dinâmica de 24 horas. Extrassístoles mais frequentes se associaram a níveis de peptídeos natriuréticos > 20mg/dL e taxas mais baixas de HDL-colesterol; além disso, foi identificada maior dilatação atrial e hipertrofia ventricular no ecocardiograma dos pacientes com esse achado, sugerindo acometimento de órgão alvo decorrente de hipertensão arterial não controlada. Portanto, a detecção de extrassístoles frequentes na monitorização eletrocardiográfica de 24 horas, em pacientes acompanhados no nível de atenção primária, reitera as recomendações dirigidas principalmente para os cuidados com os fatores de risco associados com a sua presença / Premature complexes are common findings in outpatients; thus, it is important to evaluate their clinical significance and related factors. The aim of our study was to examine the variables associated with premature beats identified in outpatients who were followed by general practitioners in a primary public healthcare setting. We performed a cross-sectional study of 407 outpatients (mean age: 55.8±12 years; 56% women) who were referred from Basic Health Units to Doctor Fernando Mauro Pires da Rocha Municipal Hospital to perform a resting 12-lead electrocardiogram for clinical follow-up. They answered a questionnaire and submitted the physical examination, fasting laboratory testing, transthoracic echocardiogram and 24-hour Holter monitoring, which were used to categorize the frequency of premature complexes. After the univariate analysis, logistic regression analyses were performed to evaluate the independent association among the variables. Premature atrial complexes ( >= 4/hour) were associated with age (odds ratio 1.030; confidence interval 95% 1.002 - 1.059; p=0.029), peptide natriuretic levels > 20mg/dL (odds ratio 4.489; confidence interval 95% 1.918 - 10.507; p=0.0005), intraventricular blocks (odds ratio 4.184; confidence interval 95% 1.861 - 9.406; p=0.0005) and left atrium diameter (odds ratio 1.065; confidence interval 95% 1.001 - 1.134; p=0.046). Premature ventricular complexes ( >= 5/hour) were associated with age (odds ratio 1.032; confidence interval 95% 1.010 - 1.054; p=0.004), the use of calcium channels blockers (odds ratio 2.248; confidence interval 95% 1.019 - 4.954; p=0.045), peptide natriuretic levels > 20mg/dL (odds ratio 2.079; confidence interval 95% 1.062 - 4.068; p=0.033), HDL-cholesterol levels (odds ratio 0.971; confidence interval 95% 0.951 - 0.992; p=0.007), heart rate (odds ratio 1.019; confidence interval 95% 1.001 - 1.038; p=0.041), left ventricle hypertrophy (odds ratio 2.292; confidence interval 95% 1.402 - 3.746; p=0.001) and left ventricle ejection fraction (odds ratio 0.938; confidence interval 95% 0.900 - 0.978; p=0.002). In our population, premature complexes were common findings on 24-hour Holter monitoring, but of low density. Frequent ectopic beats were associated with peptide natriuretic levels > 20mg/dL and lower levels of HDL-cholesterol; left atrial enlargement and ventricular hypertrophy were also identified on the echocardiograms of these patients, suggesting that target organ damage was due to uncontrolled arterial hypertension. Therefore, the identification of frequent premature complexes on 24-hour Holter monitor recording of outpatients in a primary public healthcare setting reaffirms the need for monitoring for the risk factors associated with this finding
|
9 |
Estudo das alterações da variabilidade da freqüência cardíaca e troponina no paciente séptico / Heart rate variability and troponin in septic patientsAntonio Carlos Nogueira 24 April 2006 (has links)
CONTEXTO: Estudos observacionais têm demonstrado alterações na variabilidade da freqüência cardíaca em pacientes em sepse, embora não exista publicação correlacionando lesão cardíaca causada pela inflamação sistêmica e redução da variabilidade da freqüência cardíaca. OBJETIVOS: Determinar, em pacientes em sepse, se a lesão cardíaca é causa das alterações da variabilidade da freqüência cardíaca e sua correlação com a mortalidade. Analisar também a associação entre evolução clínica e variabilidade da freqüência cardíaca, troponina, lesão celular à microscopia eletrônica e óptica e variáveis hemodinâmicas. MÉTODO: Estudo observacional, prospectivo, entre pacientes que desenvolveram sepse grave ou choque séptico, analisando sobrevida. Foram analisados: variabilidade da freqüência cardíca (alta e baixa freqüência, através da monitorização cardíaca contínua), dosagem dos níveis séricos de troponina, creatinofosfoquinase e creatinofosfoquinase fração MB, proteína C-reativa, alterações morfológicas e funcionais das células cardíacas por microscopia óptica e eletrônica e imunoistoquímica. Os dados hemodinâmicos foram obtidos por ecocardiograma e medida direta por cateter de artéria pulmonar. RESULTADOS: Dos 31 pacientes incluídos, 12 (38,7%) morreram durante o acompanhamento de 6 dias e 13 sobreviveram até o 28o dia (41,9%); 6 pacientes (19,4%) morreram nas primeiras 6 horas do estudo. O índice APACHE, utilizado como marcador prognóstico, foi igual nos dois grupos (27 +/- 2,6 nos sobreviventes e 26 +/- 2 nos não sobreviventes). A troponina plasmática se mostrou marcador de disfunção miocárdica na sepse (sobreviventes: 0,53 +/- 0,13 mg/ml, e não-sobreviventes: 2,31 +/- 1,01 mg/ml, p < 0,05), com informação prognostica, e se correlacionou com os piores dados hemodinâmicos do grupo de não-sobreviventes (índice de trabalho sistólico do ventrículo esquerdo no grupo de sobreviventes de 48,1 +/- 6,7 g.m/m2 e no de não-sobreviventes de 34,0 +/- 6,7 g.m/m2, p < 0,05). A variabilidade da freqüência cardíaca diminuída se correlacionou com pior prognóstico e a análise multivariada apontou a baixa freqüência cardíaca como uma variável independente para predizer alta da unidade de terapia intensiva (280 +/- 25 ms2 nos sobreviventes e 84 +/- 7,2 ms2 nos pacientes que evoluiram a óbito, freqüência mínima 129 +/- 19 ms2 e 65 +/- 9 ms2 na freqüência máxima, p < 0,05). A microscopia do coração evidenciou infiltrado inflamatório difuso e aumento do número de mitocôndrias e destruição destas organelas. CONCLUSÃO: Nossos resultados sugerem que a alteração da variabilidade da freqüência cardíaca está relacionada com a evolução para óbito, e correlaciona-se com a lesão cardíaca diagnosticada pela dosagem de troponina sérica e alteração do índice do trabalho sistólico do ventrículo esquerdo por sístole. A histologia do coração demonstrou importante lesão celular do coração, com destruição e aumento do número de mitocôndrias. / CONTEXT: Observational studies have shown alterations in the variability of heart rate in patients with sepsis, although there is not a published study showing correlation to cardiac lesion caused by systemic inflammation and reduction on the heart rate variability. OBJECTIVE: To determine, in patients in sepsis, if the cardiac lesion is caused by the alteration on the heart rate variability and access its correlation with mortality; and also, to analyze the association between clinical evolution and cardiac rate variability, plasmatic troponin, cellular lesion on electronic microscopy and optic and the patients\' hemodynamic data. METHOD: Observational study among patients that developed sepsis or septic shock, analyzing the survivors\' rate. The heart rate variability was analyzed (high and low rate through continuous cardiac monitorization), as well as plasma levels of troponin, CK, CK-MB, C-reactive protein, the morphologic alterations and of cardiac cells function, through electronic and optic microscopy and through immunohistochemistry. The hemodynamics\' data were analyzed though echocardiogram and pulmonary artery catheter. RESULTS: Among 31 patients included, 12 (38.7%) of them died during the course of 6 days and 13 (41.9%) survived until the 28th day, 6 (19.4%) died within the first 6 hours of the study. The APACHE index, used as a prognostic marker, was the same in both groups (27 +/- 2.6 in the survivor group and 26 +/- 2.0 in the non-survivors group). The plasmatic troponin became a marker in the myocardial dysfunction in sepsis (survivors 0.53 +/- 0.13 mg/ml and non-survivors 2.31 +/- 1.01 mg/ml, p < 0.05), with prognostic information, and it correlated with the worst hemodynamic parameters among non-survivors group (left ventricle systolic index was 48.1 +/-6.7 g.m/m2 in survivors and 34.0 +/- 6.7 g.m/m2 in non survivors group, p < 0.05). The decrease on the heart rate variability was correlated with the worst prognoses and analyses pointed to a low rate as an independent variable to predict the patients discharge from the intensive care unit (280 +/- 25 ms2 among survivors and 84 +/-7.2ms2 among non-survivors). The heart microscopy showed diffused inflammatory infiltration and increase in the number of mitochondrias and lesions in these organelles. CONCLUSION: Our results suggest that the alteration of the variability on the heart rate is related with the evolution to death, and correlated to cardiac lesion, evidenced through the dosage of troponin, and to alteration of the systolic workload of the left ventricle by systole. The heart histology demonstrated important cellular lesion of the heart, with a raise in number of and damage to mitochondrias.
|
10 |
Influências do consumo de café em diferentes torras em variáveis cardiológicas de voluntários com doença coronariana crônica / Effects of two roasts of coffee consumption on cardiological parameters in volunteers with coronary artery diseaseMioto, Bruno Mahler 11 December 2015 (has links)
INTRODUÇÃO: Os efeitos do consumo de café na frequência e ritmo cardíaco, na pressão arterial e risco cardiovascular permanecem um assunto controverso. O objetivo desse estudo foi avaliar os efeitos do consumo de café filtrado nas torra escura e média na frequência cardíaca (FC), na frequência de extrassístoles, na variabilidade de frequência cardíaca (VFC), na pressão arterial, na tolerância ao exercício e em isquemia e angina em voluntários com doença arterial coronariana (DAC). MÉTODOS: Em um ensaio clínico randomizado e com crossover, comparamos o efeito do consumo de 450 a 600 ml de café nas torras escura e média em 41 voluntários com DAC, com idade média de 64,5 ± 6,7 anos, sendo que 33 eram do sexo masculino (80,5%). Após período de washout (período basal) e após cada período de quatros semanas de consumo de café (em ambas torras), os voluntários foram submetidos a teste ergométrico (TE), monitorização ambulatorial da pressão arterial (MAPA) e eletrocardiografia dinâmica (Holter). RESULTADOS: O consumo contínuo de café não exerceu nenhum efeito deletério na isquemia miocárdica desencadeada por esforço no teste ergométrico. O tempo total de exercício (deltaT Exercício) foi de 566,59 ± 192,40, 599,39 ± 205,60 e 602,22 ± 210,24 segundos (s), respectivamente para o momento basal (após washout), após consumo de café torra escura e após consumo de café torra média (média ± DP, p = 0,002). Na MAPA, as variáveis encontradas após período basal, após consumo de café torra escura e após consumo de café torra média foram, respectivamente: pressão arterial sistólica (PAS) de 110,59 ± 12,05, 111,83 ± 12,89 e 114,32 ± 11,89 mmHg (média ± DP, p = 0,065); e pressão arterial diastólica (PAD) de 64,10 ± 8,99, 64,85 ± 9,31 e 66,27 ± 9,59 mmHg (média ± DP, p = 0,143). Os valores a seguir foram obtidos através do Holter após período basal, após consumo de café torra escura e após consumo de café torra média, respectivamente: FC Média de 67,38 ± 8,44, 66,51 ± 8,11, e 67,44 ± 8,54 (média ± DP, p = 0,59); frequência de extrassístoles supraventriculares (ESV) de 21 (75), 22 (59), e 18 (85) [mediana (intervalo interquartil), p = 0,77]; frequência de extrassístoles ventriculares (EV) de 8 (426), 10 (123), e 8 (36) [mediana (intervalo interquartil), p = 0,17]; e desvio padrão de todos os intervalos RR normais (SDNN) de 129,87 ± 32,82, 134,74 ± 30,90, e 128,31 ± 28,12 (média ± DP, p = 0,16). CONCLUSÕES: Neste estudo, o consumo contínuo de café aumentou a tolerância ao exercício, não afetou de forma significativa a pressão arterial, o ritmo e a frequência cardíaca e não aumentou a frequência de extrassístoles ventriculares e supraventriculares. Com relação a presença de isquemia e/ou angina no TE, não ocorreram modificações relacionadas ao consumo de café em ambas torras / BACKGROUND: The effect of coffee on heart rate (HR), cardiac rhythm, blood pressure (BP) and cardiovascular risk has long been a controversial issue. The aim of this study was to compare the effects of dark roast (DR) and medium-dark roast (MDR) paper-filtered coffee on HR, premature complexes, heart rate variability (HRV), BP, total exercise time (deltaT Exercise) and exercise-induced angina pectoris in volunteers with coronary artery disease (CAD). METHODS: In a randomized crossover trial, we compared the effects of consuming three to four cups (150 mL) of DR and MDR coffee per day for 4 weeks in 41 volunteers with CAD, with 64.5 ± 6.7 years old, 33 men (80.5%). At baseline and after each 4-week period of drinking, the subjects were submitted to treadmill test, ambulatory blood pressure monitoring (24-h ABPM) and 24-hour Holter electrocardiograms (24-h Holter). RESULTS: The continuous coffee consumption had no deleterious effect on exercise-induced angina pectoris on treadmill test. The deltaT Exercise at baseline and after ingesting DR and MDR were 566.59 ± 192.40, 599.39 ± 205.60 and 602.22 ± 210.24 seconds, respectively (mean ± SD, p = 0.002). The analyzed parameters on 24-h ABPM at baseline and after 4 weeks of DR and MDR coffee consumption were, respectively: systolic BP of 110.59 ± 12.05, 111.83 ± 12.89 and 114.32 ± 11.89 mmHg (mean ± SD, p = 0.065); and diastolic BP of 64.10 ± 8.99, 64.85 ± 9.31 e 66.27 ± 9.59 mmHg (mean ± SD, p = 0,143). The following values were obtained on 24-h Holter at baseline and after 4 weeks of DR and MDR coffee consumption, respectively: average HRs of 67.38 ± 8.44, 66.51 ± 8.11, and 67.44 ± 8.54 (mean ± SD, p = 0.59); premature atrial complexes of 21 (75), 22 (59), and 18 (85) [median (IQR), p = 0.77]; premature ventricular complexes of 8 (426), 10 (123), and 8 (36) [median (IQR), p = 0.17]; and standard deviations of normal to normal R-R intervals (SDNNs) of 129.87 ± 32.82, 134.74 ± 30.90, and 128.31 ± 28.12 (mean ± SD, p = 0.16). CONCLUSIONS: In this study, continuous coffee consumption increased total exercise time, did not significantly affect blood pressure, HR or HRV and did not increase the frequency of premature complexes in volunteers with CAD. Furthermore, continuous coffee consumption had no deleterious effect on exercise-induced angina pectoris
|
Page generated in 0.0958 seconds