Spelling suggestions: "subject:"elektroden"" "subject:"benelektroden""
21 |
Evaluation of dispensed carbon nanotube ink on flexible substrates for biocompatible applicationSchubert, Martin, Berg, Hendrik, Friedrich, Sabine, Bock, Karlheinz 11 February 2019 (has links)
For biomedical electronics the compatibility to the biological environment should be well-considered. Therefore this paper evaluates dispensed carbon nanotubes (CNT's) on polyimide (PI) foil for conductive tracks and electrodes for flexible, biomedical applications. A CNT based ink is investigated regarding biocompatibility, flexibility, conductivity and suitability for electrode materials with contact to artificial body fluids. The testing methods comprise bending tests with resistance monitoring, adhesion tests and the utilization of dynamic fluidic and electrical load on dispensed structures. The CNT ink showed good bending properties up to 2653 cycles with an average sheet resistance of 32.5 Ohm/sq. A demonstration of biocompatibility using the adherent cell line HFFF2 resulted negatively. No delamination or dissolving effects occurred during exposure to 0.9 % sodium chloride solution.
|
22 |
Performance-oriented strategies for integration and wiring of the photosystem I inside 2D and 3D architectures and coupling photocatalysis with enzymatic catalysisCiornii, Dmitri 02 September 2020 (has links)
In der vorliegenden Arbeit sind unterschiedliche Kopplungsstrategien des natürlichen Photosystems I (PSI) aus Cyanobakterium Thermosynechococcus elongatus mit verschiedenen Elektrodenoberflächen sowie Interaktion mit Nanomaterialien und Enzymen bearbeitet worden. Zum einen wurde gezeigt, dass die Immobilisierung des PSI auf modifizierten mehr-wandigen Kohlenstoffnanoröhrchen zur funktionalen Photobiohybridelektrode führt. Dabei wurde das PSI mit der Elektrode elektrisch mit Hilfe eines Redoxproteins, Cytochrom c (cyt c), verknüpft. Das System (PSI-cyt c) wurde auch auf eine dreidimensionale Elektrodenoberfläche des Metaloxids Indiumzinnoxid (eng. ITO) übertragen. Hierbei wurde zusätzlich die TransparenzEigenschaft solcher Oberflächen ausgenutzt. Die Präparation solcher transparenter Elektroden wurde optimiert, um höhere Photoströme zu generieren. Weiterhin wurde eine neue Methode der elektrischen Kontaktierung des PSI mit der Elektrode etabliert. Hierfür wurden Fullerene eingesetzt. Durch erhöhte molekulare Effizienz wurde gezeigt, dass Fullerene effektivere Elektronvermittler zwischen PSI und der Elektrode sind als das cyt c. Zusätzlich wurden im Rahmen dieser Doktorarbeit die photokatalytischen Eigenschaften von PSI mit den biokatalytischen Eigenschaften des Enzyms humane Sulphit Oxidase (hSOx) kombiniert. Hierbei wurde das Enzym als ein alternativer und effizienter Elektronzulieferer für PSI eingesetzt. Ein drittes Protein, das cyt c, fungierte als elektrisches Bindeglied und sicherte die elektrische Kommunikation zwischen den katalytischen Proteinen im System und der Elektrode. Die Komplexität des PSI sowie seine Kommunikation mit anorganischen Nanomaterialien und anderen komplexen Biomolekülen, wie z.B. Enzymen, zeigt ein großes Potential des Einsatzes von PSI-basierter Biohybriden in den Biotechnologien der Zukunft. / In this thesis, different strategies for coupling of the natural complex photosystem I from the cyanobacterium Thermosynechococcus elongatus with different electrode surfaces, and the interaction of PSI with nanomaterials and enzymes has been investigated. First, it was shown that immobilization of PSI on modified multi-walled carbon nanotubes (MWNT) leads to a functional photobiohybrid electrode. Here, PSI has been electrically wired to the electrode via a redox-active protein, cytochrome c (cyt c). The system (PSI-cyt c) has been scaled up to the three-dimensional surface of a metal-oxide, indium tin oxide (ITO). Here, additionally the high transparency property of this material has been exploited. The new preparation procedure of such transparent electrodes has been optimized in order to achieve high pohotocurrents. Furthermore, a new method of electric wiring of the PSI with the electrode has been established. Here, fullerenes have been employed. The high molecular efficiency of such a system proves that fullerenes are more effective wiring agents between the PSI and the electrode as compared to the cyt c. Additionally, in this thesis the photocatalytic property of the PSI has been combined with the biocatalytic property of the enzyme human sulphite oxidase, hSOx. Here, the enzyme has been employed as an alternative electron supplier for PSI. The third protein, cyt c, acted as an electric wiring agent and ensured electric communication between both catalytic proteins of the system and the electrode. The versatility of the PSI as well as its communication with anorganic nanomaterials and biological molecules, e.g. such as enzymes, shows a great potential for use of PSI-based biohybrids in the future biotechnological applications.
|
23 |
Laser-based Sustainable Electrode Design for Electrochemical ApplicationsMoon, Sanghwa 13 November 2024 (has links)
Laser sind seit ihrer Erfindung im Jahr 1960 essenziell für die Materialbearbeitung und bieten Präzision, Effizienz und Nachhaltigkeit. Während sie anfangs hauptsächlich für die Makrobearbeitung eingesetzt wurden, haben Fortschritte bei kurzwelligen und ultrakurz gepulsten Lasern die präzise Mikro- und Nanobearbeitung ermöglicht, was dem wachsenden Bedarf an umweltfreundlicher Fertigung entspricht. Diese Arbeit konzentriert sich auf zwei laserbasierte Techniken für die nachhaltige Elektrodenproduktion: Laser-induced forward transfer (LIFT) und Laserkohlenstoffisierung. Kapitel 1 führt diese Methoden ein. Kapitel 2 untersucht LIFT für den Polymertransfer, wobei die Oberflächenhaftung und Benetzungseigenschaften untersucht werden, um definierte Polymermikrostrukturen zu erzeugen. Die Studie bietet Einblicke in die Optimierung polymerbasierter Geräte und stellt die LIFT-unterstützte Synthese von Metalloxidmustern für Elektrodenstrukturen und Heteroübergänge vor. Kapitel 3 befasst sich mit der Laserkohlenstoffisierung unter Verwendung von sodium lignosulfonate (SLS), einem Nebenprodukt der Papierindustrie, als nachhaltigem Kohlenstoffvorläufer. Durch die Integration einer haftenden Polymerschicht werden robuste, laser patterned carbon (LP-C) in einem einzigen Schritt hergestellt. Diese LP-C-Elektroden, deren Eigenschaften anpassbar sind, zeigen eine hervorragende Leistung in Superkondensatoren und Dopaminsensoren und weisen eine hohe Kapazität, Energiedichte und Stabilität auf. Diese Arbeit hebt das Potenzial von SLS-basierten LP-C-Elektroden für nachhaltige Energiespeicherung und Biosensorik hervor und trägt zur Weiterentwicklung umweltfreundlicher elektrochemischer Systeme bei. / Lasers have been essential in materials processing since their invention in 1960, offering precision, efficiency, and sustainability. While initially used for macro processing, advances in short-wavelength and short-pulse lasers have enabled precise micro- and nano-scale processing, aligning with the growing demand for eco-friendly manufacturing. This thesis focuses on two laser-based techniques for sustainable electrode production: Laser Induced Forward Transfer (LIFT) and laser carbonization. Chapter 1 introduces these methods. Chapter 2 explores LIFT for polymer transfer, investigating surface adhesion and wetting properties to create defined polymer microstructures. The study provides insights into optimizing polymer-based devices and presents LIFT-assisted metal oxide synthesis for patterned electrode structures and heterojunctions. Chapter 3 examines laser carbonization using sodium lignosulfonate (SLS), a paper industry byproduct, as a sustainable carbon precursor. By integrating an adhesive polymer layer, robust laser-patterned carbon (LP-C) electrodes are fabricated in a single step. These LP-C electrodes, with tunable properties, show excellent performance in supercapacitors and dopamine biosensors, demonstrating high capacitance, energy density, and stability. This work highlights the potential of SLS-based LP-C electrodes for sustainable energy storage and biosensing applications, advancing eco-friendly electrochemical systems.
|
24 |
Flexible transparent electrodes for optoelectronic devicesKinner, Lukas 01 March 2021 (has links)
Transparente Elektroden (TE) sind unverzichtbar in modernen optoelektronischen Bauelementen. Die derzeitig am häufigsten verwendete TE ist Indium Zinn Oxid (ITO). Aufgrund der Nachteile von ITO setzt sich die vorliegende Arbeit mit ITO-Alternativen auseinander. Zwei Ansätze werden in dieser Arbeit untersucht. Der erste Ansatz beruht auf Dielektrikum/Metall/Dielektrikum (DMD) Filmen, im zweites Ansatz werden Silber Nanodrähten (NW) als TE untersucht. Im ersten Ansatz wurden DMD Elektroden auf Glas und Polyethylenterephthalat (PET) fabriziert. Eine Kombination von gesputterten TiOx/Ag/AZO Schichten lieferte die höchste jemals gemessene Transmission und Leitfähigkeit für eine Elektrode auf Glas und PET. Eine durchschnittliche Transmission größer als 85 % (inklusive Substrat) im Bereich von 400-700 nm und einen Schichtwiderstand von unter 6 Ω/sq wurden erreicht. Um die Leistung der TiOx/Ag/AZO Elektrode in einem Bauteil zu überprüfen, wurde sie in einer organischen Licht emittierenden Diode (OLED) implementiert. Die DMD-basierten OLEDs erreichten eine 30 % höhere Strom Effizienz auf Glas und eine 260 % höhere Strom Effizienz auf PET im Unterschied zu den ITO-basierten Bauteilen. Im zweiten Ansatz zur Realisierung flexibler transparenter Elektroden wurden NWs diskutiert. Die Implementierung von Nanodrähten in lösungsprozessierten organischen Licht emittierenden Dioden weißt noch immer zwei große Hürden auf: hohe Rauigkeit der Nanodrahtfilme und Wärmeempfindlichkeit von PET. Um die Rauigkeit zu verkleinern und gleichzeitig die Stabilität zu erhöhen werden zunächst die Nanodrähte in ein UV-härtendes Polymer eingebettet. Es wird eine Transmission von bis zu 80 % (inklusive Substrat) und ein Schichtwiderstand von 13 Ω/sq erreicht. Gleich wie bei den DMD Elektroden wurden auch NW Elektroden in eine OLED implementiert. Die Bauteile zeigten eine größere Flexibilität, Leitfähigkeit und Luminanz als die PET/ITO Referenzen während die selbe Leistungseffizienz erreicht wurde. / Transparent electrodes (TEs) are a key element in optoelectronics. TEs assure simultaneous light interaction with the active device layers and efficient charge carrier injection or extraction. The most widely used TE in today’s industry is indium tin oxide (ITO).
However, there are downsides to the use of ITO. The scope of this thesis is to discuss alternatives to ITO. Two main approaches are examined in this thesis - one approach is based on using dielectric/metal/dielectric (DMD) films and the other is based on using silver nanowire (NW) films.
For the first approach, a combination of sputtered TiOx/Ag/AZO was found to yield the highest transmittance and conductivity ever reported for an electrode on PET with an average transmittance larger than 85 % (including the substrate) in the range 400-700 nm and sheet resistance below 6 Ω/sq.
To test the device performance of TiOx/Ag/AZO, DMD electrodes were implemented in organic light emitting diodes (OLEDs). DMD-based devices achieve up to 260 % higher efficacy on PET, as compared to the ITO-based reference devices.
As a second approach, NWs were investigated. The implementation of silver nanowires as TEs in solution processed organic light emitting diodes still faces two major challenges: high roughness of nanowire films and heat sensitivity of PET. Therefore, within this thesis, an embedding process with different variations is elaborated to obtain highly conductive and transparent electrodes of NWs on flexible PET substrates.
The NWs are embedded into a UV-curable polymer, to reduce the electrode roughness and to enhance its stability. A a transmittance of 80 % (including the substrate) and sheet resistance of 13 Ω/sq is achieved.
|
25 |
Elektrische Stimulation von Zellen und Geweben am besonderen Beispiel von KnochenzellenHabel, Beate 18 May 2004 (has links)
Die Basis für den therapeutischen Einsatz elektrischer Felder bei der Behandlung von Knochenbrüchen liegt in der Existenz von belastungsabhängigen elektrischen Potentialen im Knochen. Die zellulären Wirkungsmechanismen sind jedoch unverstanden. Um zu untersuchen, ob und wie elektrische Felder Wachstum und Differenzierung von Knochenzellen beeinflussen, wurden humane Osteosarcomazellen (HOS TE85) und aus Minischweinen isolierte primäre Osteoblasten mit elektrischen Feldern im Frequenzbereich von 0.1 Hz bis 100 kHz befeldet und verschiedene zelluläre Parameter zeitabhängig gemessen. Das elektrische Feld wurde mittels platinierten Platinelektroden appliziert, um ausreichend hohe Feldstärken bei gleichzeitig guter Kontrolle über die im Gewebe erzeugte Wellenform zu gewährleisten. Beim Einsatz von Elektroden müssen jedoch elektrochemische Reaktionen an der Elektrodenoberfläche berücksichtigt werden. Daher wurden verschiedene Elektroden für die in vivo- und in vitro-Stimulation mit elektrischen und numerischen Methoden untersucht und verglichen. Das führte einerseits zur Erarbeitung verschiedener Kriterien zur Auswahl geeigneter Elektrodenmaterialien und -geometrien. Andererseits konnten detaillierte Angaben zur effektiven Feldstärke und Feldverlauf in der Zellebene sowie zu elektrochemisch bedingten Nebenwirkungen gemacht werden. Es konnte gezeigt werden, dass elektrische Felder das Signalsystem und den Stoffwechsel von Knochenzellen im gesamten untersuchten Frequenzbereich beeinflussen. Die Richtung des Nettoeffekts war jedoch im oberen und im unteren Frequenzbereich unterschiedlich. Im Frequenzbereich über 1 kHz fanden wir immer eine Erhöhung des Wachstums und der Konzentration der "second messenger" und eine Herabsetzung der Konzentration der reaktiven Sauerstoffverbindungen (ROS). Bei Frequenzen unter 1 kHz wurde dagegen eine Erhöhung der Aktivität der alkalischen Phosphatase und des oxidativen Stress beobachtet. Signifikante Effekte traten jedoch nur bei Feldstärken oberhalb 100 V/m auf. Hinweise auf bevorzugte Frequenzen oder Wellenformen, die für "Fenstereffekte" sprechen würden, konnten nicht gefunden werden. Da alle zellulären Parameter an einem einheitlichen System gemessen wurden, ließen sich die Ergebnisse in ein Modell der feldinduzierten Signaltransduktion integrieren. Prinzipiell muss man von einem gemeinsamen Effekt mehrerer Signalwege ausgehen. Dabei kann die Erhöhung der intrazellulären Kalziumkonzentration als ein genereller Mechanismus der Feldwirkung angesehen werden. Dafür sind sowohl der Influx als auch die Freisetzung von Kalzium aus intrazellulären Speichern verantwortlich. Es konnte weiterhin gezeigt werden, dass auch cGMP und Prostaglandin E2, jedoch nicht cAMP an der Vermittlung der Feldwirkung beteiligt ist. Außerdem wurde die Translokation der mitogen-aktivierten Proteinkinase (MAPK) beeinflusst. Trotzdem sind die beobachteten Effekte relativ schwach im Vergleich zu publizierten klinischen Erfolgen. Es muss daher in vivo Verstärkungsmechanismen geben, die durch Untersuchungen an Zellkulturen nicht erfasst werden können. / The therapeutic use of electric fields in the treatment bone fracture healing is based on the existence of different load dependent electric potentials in bone. However, the cellular mechanisms of field action are still not understood. We investigated the effect of electric fields on proliferation and differentiation of human osteosarcoma cells (HOS TE85) and primary osteoblasts isolated from mini pigs. The cells were exposed to electric fields (0.1 Hz - 100 kHz) and various cellular parameters were measured. The field was applied using platinized platinum electrodes ensuring sufficiently strong electric fields and a well controlled wave form in the tissue. Nevertheless, in this case electrochemical reactions which occur at the electrode surface have to be taken into account. That’s why various electrodes for in vivo and in vitro stimulation are characterized by electrical and numerical methods leading not only to criteria for choosing electrode materials and geometries, but also providing detailed knowledge about the electric field induced in the tissue and electrochemically induced side effects. We found that cellular signaling as well as proliferation and differentiation of bone cells are influenced by electric fields in the whole investigated frequency range. Proliferation and the second messenger concentrations are increased at frequencies above 1 kHz, whereas below 1 kHz the alkaline phosphatase activity is increased. Significant effects were found only for electric fields above 100 V/m, but we could not find any hints on preferred frequencies or wave forms ruling out "window effects". Because all cellular parameters were measured within one experimental system, the results can be summarized in a signal transduction model for the action of electric fields. Generally, a common action of multiple signaling pathways has to be assumed. The increase of the intracellular calcium concentration can be considered as a general mechanism of field action. This increase is caused by calcium release from intracellular calcium stores as well as influx of extracellular calcium. Additionally, the concentration of cGMP and prostaglandin E2, but not that of cAMP is increased by the electric field. Furthermore, the translocation of the mitogen activated protein kinase (MAPK) is influenced. Nevertheless, the field effects found are weak compared to those published in clinical studies. We suppose that there are amplifying mechanisms in vivo which could not be seen during in vitro investigations.
|
26 |
Tiefdruckverfahren zur Herstellung von Katalysatorschichten für (PEM) Brennstoffzellen / Gravure Printing as Manufacturing Technology for Catalyst Layers of (PEM) Fuel CellsSiegel, Frank 06 June 2016 (has links) (PDF)
Diese Dissertation befasst sich mit der industrienahen Herstellung von Katalysatorschichten für Polymer-Elektrolyt-Membran-Brennstoffzellen mit Hilfe des Tiefdrucks als Fertigungsverfahren. Um die Anforderungen an die Katalysatorschicht hinsichtlich der Schichtdicke zu erreichen, wird ein Linienraster für den Tiefdruck entwickelt. Das patentierte und verifizierte Designkonzept des Linienrasters ermöglicht es, trotz Tinten mit geringem Feststoffgehalt hohe Trockenschichtdicken zu erzeugen. Aufgrund des verwendeten Tiefdruckrasters sind Optimierungsschritte an der Fertigungsanlage notwendig, um eine hohe Schichtqualität zu erreichen. Schließlich werden kontinuierlich und industrienah Katalysatorschichten gefertigt, die als Membran-Elektroden-Einheit in einer Polymer-Elektrolyt-Membran-Brennstoffzelle erfolgreich eingesetzt werden. / This work presents an industrial close manufacturing process of active electrodes for Polymer Electrolyte Fuel Cells utilizing an adapted gravure printing process. To meet the requirements of the electrodes regarding the layer thickness (weight) and quality a novel line screen with maximized dipping volume for gravure printing was developed and investigated. A design rule for this kind of screens was realized and verified by a successful manufacturing of electrodes with different dried layer thicknesses. Due to the rough structure and the high dipping volumes of these line screens an adaption and optimization of the machinery and the whole process was necessary to achieve high quality electrodes. Finally, it is shown that it is possible to manufacture continuiously in an industrial close roll-to-roll process platinum loaded electrodes, working successful as cathode in a Membran-Electrode-Assembly.
|
27 |
Impedimetric Sensor System for Edible Oil Quality AssessmentFendri, Ahmed 18 March 2020 (has links)
The repeated usage of frying oil is hazardous due to the degradation caused by chemical reactions, which happen while heating. The total polar compounds and the free fatty acids are the main two chemical parameters affected by frying. These parameters increase significantly with the use of oil for frying and are reported as reasons for causing serious illnesses like heart diseases.
For this purpose, sensor systems for oil quality assessment are necessary. In fact, changes of the composition due to frying leads to variation of its dielectric parameters. This can be measured using a capacitive sensor and the measurement of its impedance change. The main challenge thereby is that the impedance changes are very small and stray capacitances have a big influence on the measurements.
In this context, this work proposes a sensor system with high accuracy able to detect the small changes that occur in the resistance and capacitance under influence of stry capacitances. Theoretical and simulation studies are carried out for different cap acitive sensors as well as meas urement procedures of its cornp lex imp edance.
The sensor should provide a high sensitivity to relative perrnittivity and the electrical conductiv ity, and at the same time a small size and a high reproducibility. Interdigital electrodes sensor with a suitable design fulfils all these requirements.
A deep consideration of stray capacitances is needed to realize an accurate sensor system. For t hese reasons, the design of the measurement circuit is crucial within this work. We propose, a measurernent circuit based on a combinat ion of the method of capacitance to voltage conversion and the phase shift measurement method. By cornbining both rnethods together it is possible to rneasure accurate ly the complex irnpedance of edible oil. Experimental results show that measurement systern is capable to detect small changes of dielectric parameters, which are correlated to the chemical parameters. / Die mehrfach wiederholte Verwendung von Frittieröl ist aufgrund der Qualitätsver schlechterung, die während des Erhitzens auftreten durch chemische Reaktionen verursacht wird, gefährlich für die Gesundheit. Die totale polaren Kompon enten und die freien Fettsäuren sind die zwei wichtigsten chemischen Komponenten, die wesentlich durch das Braten beeinflusst werden. Diese Komponenten erhöhen sich signifikant mit der Wiederverwendung von Bratöl und verursachen u. a. ernste Herzkrankheiten.
Diese Arbeit zielt darauf hin, ein mobiles, kostengünstiges, einfach zu verwenden des Sensorsystem für die Abschätzung der Ölqualität zu entwickeln. Das System charakterisiert die Veränderung der elektrischen Parameter des Öls durch Messung der Änderung seiner komplexen elektrischen Eigenschaft en.
In dieser Arbeit wurde ein Sensorelement mit interdigitalen Elektroden entwickelt, der eine hohe Empfindlichkeit auf die relative Permittivität und die elektrischen Leitfähigkeit des Öls hat und dabei einer hohe Reproduzierbarkeit erzielen kann.
Es wird ein Messverfahren vorgeschlagen, das auf der Wandlung in einer Spannung und einer Phasenverschiebung basiert. Sowohl durch theoretische Überlegungen als auch durch Simulationen konnte belegt werden, dass die Kombination beider Metho den eine akkurate Messung der Komplexem Imped anz hochdielektrischer Materia lien ermöglichen kann. Experiment elle Ergebnisse zeige n, dass das Messsystem in der Lage ist , kleine Änderungen der dielektrischen Parameter zu erfassen, die mit den chemischen Ölparamtern stark korrelieren.
|
28 |
Additive Fertigung von Keramiken mittels Mikrofluidik und elektrophoretischer AbscheidungVogt, Lorenz 14 January 2021 (has links)
In dieser Dissertation wurde untersucht, inwieweit die Kombination von Mikrofluidik mit elektrophoretischer Formgebung zur additiven Herstellung von Keramikbauteilen genutzt werden kann. Mit Verfahren der Mikrofluidik sollten räumliche Strukturierung und Materialdifferenzierung erfolgen, während die elektrophoretische Abscheidung für die Ausbildung einer homogenen Mikrostruktur sorgt. Es wurde eine Versuchsanlage aufgebaut, die eine kontrollierte elektrophoretische Abscheidung von Keramikpartikeln, die durch eine Hohlelektrode zugeführt werden, auf porösen Membranen ermöglicht. Die Anlage bietet – im Unterschied zu bereits beschriebenen Verfahren – das Potenzial für eine hochgradige Parallelisierung und Multimaterialdruck. Schließlich wurden Finite-Elemente-Modelle zur Feldverteilung und zur Partikelbewegung entwickelt, mit denen die experimentellen Ergebnisse verglichen wurden. Bei den Versuchen traten viele in ihrem Ausmaß nicht erwartete Phänomene auf: elektrohydrodynamische Effekte und nichtelektrisch verursachte Strömungen des Lösungsmittels, die die Ausbeute und Reproduzierbarkeit sowie die Eigenschaften der abgeschiedenen Strukturen verschlechterten, was zusätzlichen Untersuchungen notwendig machte. In Ethanol wurden relevante Abscheideparameter systematisch variiert und die Struktur und das Gefüge der abgeschiedenen Al2O3-Partikel methodisch analysiert.
Die Arbeit war Teil eines von der Deutschen Forschungsgemeinschaft geförderten Sachbeihilfe-Projekts (KU 1327/10-1 | RA 614/7-1).:Inhaltsverzeichnis
1 Einleitung 7
2 Stand der Forschung 8
2.1 Stand der Forschung additive Fertigung keramischer Bauteile 8
2.1.1 Feedstockbasierte additive Fertigungsverfahren 9
2.1.2 Pulverbasierte additive Fertigungsverfahren: 10
2.1.3 Schlickerbasierte additive Fertigungsverfahren 11
2.2 Stand der Forschung elektrophoretische Abscheidung 12
2.3 Stand der Forschung Dielektrophorese 15
2.4 Stand der Forschung EHD-Effekt 16
3 Methodisches Vorgehen 19
3.1 Allgemeiner Aufbau 19
3.2 Elektroden 22
3.3 Lösungsmittel 24
3.4 Abscheidemembranen 25
3.5 Partikel und Suspensionen 27
3.6 Durchführung der Depositionsexperimente 30
3.7 Analyse der abgeschiedenen Strukturen 32
3.7.1 Konfokale 3D Laserscanningmikroskopie (CLSM) 32
3.7.2 Dynamische Differenzkalorimetrie und Thermogravimetrie (DSC/TGA) 33
3.7.3 Rasterelektronenmikroskopie (REM) und Varianzanalyse 33
4 Computersimulationen 35
5 Experimentelle Ergebnisse 41
5.1 Untersuchung des EHD-Effekts 41
5.2 Abscheidung mit verschiedenen Lösungsmitteln und Partikeln 45
5.3 Abscheidung von PEI-Aluminiumoxidpartikeln in Ethanol 51
5.4 DSC-TGA einer bedruckten Membran 60
5.5 Varianzanalyse der Gefügehomogenität elektrophoretisch abgeschiedener
Proben 63
6 Zusammenfassung und Ausblick 66
7 Quellenverzeichnis 69
8 Formelverzeichnis 78
9 Tabellenverzeichnis 78
10 Abbildungsverzeichnis 79
11 Anhang 83 / In this dissertation it was examined to what extent the combination of microfluidics with electrophoretic shaping can be used for the additive manufacturing of ceramic components. The spatial structuring and material differentiation should take place using microfluidic methods, while the electrophoretic deposition ensures the formation of a homogeneous microstructure. A test facility was set up that enables controlled electrophoretic deposition of ceramic particles, which are fed through a hollow electrode, onto porous membranes. In contrast to known processes, the system offers the potential for high-quality parallelization and multi-material printing. Finally, finite element models for field distribution and particle movement were developed, with which the experimental results were compared. During the experiments, many phenomena that were not expected occurred: electrohydrodynamic effects and non-electrically induced solvent flows, which reduced the yield and reproducibility as well as the properties of the deposited structures, that made additional studies necessary. We systematically varied relevant deposition parameters in the solvent ethanol and the microstructure of the deposited Al2O3 particles was methodically analyzed.
The work was part of a research grant project funded by the German Research Foundation (KU 1327 / 10-1 | RA 614 / 7-1).:Inhaltsverzeichnis
1 Einleitung 7
2 Stand der Forschung 8
2.1 Stand der Forschung additive Fertigung keramischer Bauteile 8
2.1.1 Feedstockbasierte additive Fertigungsverfahren 9
2.1.2 Pulverbasierte additive Fertigungsverfahren: 10
2.1.3 Schlickerbasierte additive Fertigungsverfahren 11
2.2 Stand der Forschung elektrophoretische Abscheidung 12
2.3 Stand der Forschung Dielektrophorese 15
2.4 Stand der Forschung EHD-Effekt 16
3 Methodisches Vorgehen 19
3.1 Allgemeiner Aufbau 19
3.2 Elektroden 22
3.3 Lösungsmittel 24
3.4 Abscheidemembranen 25
3.5 Partikel und Suspensionen 27
3.6 Durchführung der Depositionsexperimente 30
3.7 Analyse der abgeschiedenen Strukturen 32
3.7.1 Konfokale 3D Laserscanningmikroskopie (CLSM) 32
3.7.2 Dynamische Differenzkalorimetrie und Thermogravimetrie (DSC/TGA) 33
3.7.3 Rasterelektronenmikroskopie (REM) und Varianzanalyse 33
4 Computersimulationen 35
5 Experimentelle Ergebnisse 41
5.1 Untersuchung des EHD-Effekts 41
5.2 Abscheidung mit verschiedenen Lösungsmitteln und Partikeln 45
5.3 Abscheidung von PEI-Aluminiumoxidpartikeln in Ethanol 51
5.4 DSC-TGA einer bedruckten Membran 60
5.5 Varianzanalyse der Gefügehomogenität elektrophoretisch abgeschiedener
Proben 63
6 Zusammenfassung und Ausblick 66
7 Quellenverzeichnis 69
8 Formelverzeichnis 78
9 Tabellenverzeichnis 78
10 Abbildungsverzeichnis 79
11 Anhang 83
|
29 |
3D printed flexible substrate with pneumatic driven electrodes for health monitoringSchubert, Martin, Friedrich, Sabine, Wedekind, Daniel, Zaunseder, Sebastian, Malberg, Hagen, Bock, Karlheinz 11 February 2019 (has links)
Telemedical methods enable remote patient monitoring and healthcare at a distance. Besides, fitness tracker and sport watches are currently trending electronic products to generate awareness of health parameters in daily life. Especially, the long-term and continuous measurement of electrophysiological signals such as electrocardiogramm (ECG) becomes increasingly attractive for telemedical applications. Typically used disposable Ag/AgCl wet electrodes for good skin-electrode contact can potentially cause skin irritation and rashes. This paper presents a low cost, individual and flexible substrate for skin electrodes to be applied in future consumer electronic or professional applications. It enables an alternative contact method of the electrode to the skin by applying a pressure during the measurement and hence good contact. If no measurement is needed pressure can be released and the electrode loses skin contact. The 3D printed polymer module is 4 mm thick and comprises a pressure chamber, silver electrodes and insulation layer. The airtight printed membrane of flexible filament, which expands when inflating the chamber, may be printed in different thicknesses and shapes, much thinner than the present 4mm. This enables a high individuality for various applications. Pressure up to 150 kPa was applied and leads to dilatation of 1400 μm. First tests on skin when measuring electrodermal activity (EDA) show promising results for future applications.
|
30 |
Tiefdruckverfahren zur Herstellung von Katalysatorschichten für (PEM) BrennstoffzellenSiegel, Frank 23 November 2015 (has links)
Diese Dissertation befasst sich mit der industrienahen Herstellung von Katalysatorschichten für Polymer-Elektrolyt-Membran-Brennstoffzellen mit Hilfe des Tiefdrucks als Fertigungsverfahren. Um die Anforderungen an die Katalysatorschicht hinsichtlich der Schichtdicke zu erreichen, wird ein Linienraster für den Tiefdruck entwickelt. Das patentierte und verifizierte Designkonzept des Linienrasters ermöglicht es, trotz Tinten mit geringem Feststoffgehalt hohe Trockenschichtdicken zu erzeugen. Aufgrund des verwendeten Tiefdruckrasters sind Optimierungsschritte an der Fertigungsanlage notwendig, um eine hohe Schichtqualität zu erreichen. Schließlich werden kontinuierlich und industrienah Katalysatorschichten gefertigt, die als Membran-Elektroden-Einheit in einer Polymer-Elektrolyt-Membran-Brennstoffzelle erfolgreich eingesetzt werden. / This work presents an industrial close manufacturing process of active electrodes for Polymer Electrolyte Fuel Cells utilizing an adapted gravure printing process. To meet the requirements of the electrodes regarding the layer thickness (weight) and quality a novel line screen with maximized dipping volume for gravure printing was developed and investigated. A design rule for this kind of screens was realized and verified by a successful manufacturing of electrodes with different dried layer thicknesses. Due to the rough structure and the high dipping volumes of these line screens an adaption and optimization of the machinery and the whole process was necessary to achieve high quality electrodes. Finally, it is shown that it is possible to manufacture continuiously in an industrial close roll-to-roll process platinum loaded electrodes, working successful as cathode in a Membran-Electrode-Assembly.
|
Page generated in 0.4316 seconds