• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 160
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 166
  • 166
  • 166
  • 93
  • 74
  • 33
  • 28
  • 28
  • 24
  • 23
  • 23
  • 19
  • 16
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Achados clínicos e da análise videofluoroscópica da deglutição em pacientes com doença pulmonar obstrutiva crônica / Clinical and videofluoroscopic evaluation of swallowing in patients with chronic obstructive pulmonary disease

Rosane de Deus Chaves 15 April 2014 (has links)
Indivíduos com doença pulmonar obstrutiva crônica (DPOC) apresentam sintomas de disfagia, indicando a existência de alteração da deglutição nessa população. O objetivo da presente tese foi identificar as características da deglutição nos pacientes com DPOC. A deglutição foi avaliada por meio do exame videofluoroscopia da deglutição. Foi utilizado um protocolo para análise dos seguintes parâmetros: tempo de trânsito faríngeo, duração do contato da base de língua com a parede posterior da faringe, resíduo em valécula e penetração/aspiração. Os resultados foram analisados através de dois estudos. No primeiro estudo foi verificada a reprodutibilidade do protocolo para análise da videofluoroscopia da deglutição em uma população de adultos saudáveis. Foram avaliados 20 indivíduos saudáveis, de ambos os gêneros, com idades entre 50 e 65 anos. O protocolo consistiu na avaliação da deglutição de 10ml de consistência líquida. A análise estatística envolveu a avaliação da reprodutibilidade do método de análise entre juízes e a análise dos dados quantitativos, levando-se em consideração os gêneros. Em relação à análise das respostas dos juízes, foi observada significância estatística, com alta e boa reprodutibilidade para todas as comparações realizadas. Não foram encontradas diferenças estatisticamente significantes para o tempo de trânsito faríngeo; para a duração do contato da base de língua na parede posterior da faringe; e para a porcentagem de resíduo na valécula. Não houve penetração/aspiração para nenhuma das consistências testadas. Concluindo, os resultados indicaram que o protocolo para análise da videofluoroscopia da deglutição é reprodutível. Os parâmetros de deglutição avaliados não se diferenciaram entre os gêneros. O resíduo na valécula mostrou-se presente em 40% da amostra, sugerindo que este parâmetro, isoladamente, não é indicativo de alteração para essa faixa etária. No segundo estudo foram avaliados 20 pacientes com DPOC, que foram comparados a 20 indivíduos saudáveis, pareados por gênero e idade. O protocolo consistiu na avaliação da deglutição de consistência líquida, pastosa e sólida. Os participantes do estudo não apresentaram sinais de penetração/aspiração para nenhuma das consistências testadas. Os pacientes com DPOC apresentaram maior duração do tempo de trânsito faríngeo para a consistência líquida e pastosa. Em relação à duração do contato de base de língua com a parede posterior da faringe, os pacientes com DPOC apresentaram maior duração para as consistências liquida e pastosa. Não foi observada diferença estatisticamente significante para a distribuição dos indivíduos nos diferentes níveis de resíduo faríngeo. Concluindo, o presente estudo sugere que os pacientes com DPOC podem apresentar adaptações fisiológicas como uma manobra protetora da deglutição para evitar penetração/ aspiração de conteúdo faríngeo. Os resultados indicam que o resíduo em valécula não pode ser considerado um fator isolado para explicar as alterações de deglutição nessa população / Individuals with chronic obstructive pulmonary disease (COPD) present symptoms of dysphagia, indicating that swallowing is altered in this population. The purpose of the present thesis was to identify swallowing characteristics of patients with COPD. Swallowing was assessed through videofluoroscopic examination. A protocol was used aiming at the following parameters: pharyngeal transit time; duration of the tongue base contact with the posterior pharyngeal wall; valleculae residue and penetration/aspiration. The results were presented in two different studies. The first study verified the reproducibility of the adopted protocol in healthy adults. Twenty healthy individuals of both genders, with ages between 50 and 65 years were assessed. The protocol consisted in analyzing the swallow of 10ml of a liquid consistency. The statistical analysis involved the verification of the reproducibility of the results between judges and the analyses of the quantitative data (i.e. differences between genders). This first analysis indicated that reproducibility was high between the judges for all of the comparisons. No statistical differences were found between genders for any of the tested parameters (i.e. pharyngeal transit time; duration of the tongue base contact with the posterior pharyngeal wall; and percentage of valleculae residue). Penetration/aspiration was not observed for any of the tested food consistencies. The results of the first study indicated that the protocol used to analyze the videofluoroscopy of swallow is reproducible. The investigated swallowing parameters did not vary between genders. Valleculae residue was present in 40% of the studied sample, suggesting that this parameter alone does not indicate swallowing alterations in this age group. In the second study, the swallow of 20 patients with COPD was compared to 20 healthy individuals, paired by age and gender. The protocol consisted of analyzing the swallow of liquid, paste and solid food consistencies. Participants of the study did not present any signs of penetration/aspiration for any of the tested food consistencies. Patients with COPD presented longer pharyngeal transit times for the liquid and paste consistencies. Regarding the duration of the tongue base contact with the posterior pharyngeal wall, patients with COPD presented longer durations for the liquid and paste consistencies. No statistical difference was observed for the distribution of individuals among the different severity levels of valleculae residue. The results of the second study suggest that patients with COPD can present physiologic adaptations (i.e. protective maneuver) to avoid penetration/aspiration. The results also indicate that valleculae residue should not be considered the only factor responsible for swallowing alterations in this population
82

Questionário de Frequência Alimentar Quantitativo para crianças de 7 a 10 anos: avaliação das propriedades psicométricas / Quantitative Food Frequency Questionnaire: evaluation of psychometric properties

Patricia de Fragas Hinnig 31 July 2014 (has links)
Introdução: Um Questionário de Frequência Alimentar Quantitativo (QUEFAC) foi construído por HINNIG et al. (2014) para avaliar a dieta habitual de crianças de 7 a 10 anos, uma vez que os desenvolvidos para adultos podem superestimar o consumo de crianças. No entanto, não foi testado quanto à sua validade e reprodutibilidade para que o instrumento possa ser utilizado em pesquisas. Objetivo: avaliar a reprodutibilidade e a validade do QUEFAC para a amostra como um todo e avaliar a validade estratificada por sexo, faixa etária e nível socioeconômico. Métodos: o estudo de reprodutibilidade foi realizado no município de Araraquara, em abril de 2013, com 89 crianças de 7 a 10 anos que responderam a dois QUEFACs com intervalo de 15 dias entre as aplicações. O estudo de validade foi realizado com 167 crianças de duas escolas do município de São Paulo de agosto a dezembro de 2013. Neste, as crianças responderam a três Recordatórios de 24 horas (R24h) que serviram como método de referência e a um QUEFAC. Em ambos os estudos, os responsáveis pelas crianças responderam a um questionário socioeconômico e realizou-se a avaliação da habilidade da criança em responder ao QUEFAC. Para avaliação da reprodutibilidade e validade, utilizaram-se o teste de diferença de médias para amostras pareadas (teste t pareado e Wilcoxon), calcularamse os coeficientes de correlação intraclasse e Kappa ponderado, além da análise dos gráficos de Bland-Altman. Resultados: mais de 55 por cento das crianças foram avaliadas com habilidade boa, muito boa ou excelente em todos os aspectos avaliados ao responder o QUEFAC. No estudo de reprodutibilidade, observou-se diferença de médias entre uma aplicação e outra do QUEFAC para todos os nutrientes investigados, o coeficiente de correlação intraclasse variou de 0,12 a 0,54, valores de Kappa ponderado de 0,01 a 0,39 e os gráficos de Bland-Altman mostraram distribuição aleatória para todos os nutrientes. No estudo de validade para amostra como um todo, observou-se diferença de média para todos os nutrientes, com exceção da energia e zinco, os coeficiente de correlação intraclasse variaram de 0 a 0,37, valores de Kappa ponderado de 0 a 0,27 e gráficos de Bland-Altman mostraram distribuição aleatória dos dados para lipídios, carboidratos, cálcio, fósforo, sódio, zinco, vitaminas B1, B2, niacina, vitamina C, retinol e gordura saturada. A avaliação da validade estratificada por sexo, faixa etária e nível socioeconômico apresentou resultados semelhantes. Conclusão: O QUEFAC não se mostrou válido para avaliação da dieta habitual dos últimos 3 meses em crianças de 7 a 10 anos residentes em São Paulo e apresentou moderada reprodutibilidade para energia, proteínas, cálcio, fósforo, ferro, potássio, magnésio e vitamina B2. / Introduction: A Quantitative Food Frequency Questionnaire (QUEFAC) was developed by Hinnig et al. (2010 ) to assess the usual intake of children aged 7 to 10 years, because instruments developed for adults may overestimate food consumption of children. However, it was not tested for validity and reliability, so that the instrument can be used in research. Objective: to assess the reproducibility and validity of QUEFAC for the sample as a whole and to evaluate the validity stratified by sex, age group and socioeconomic status. Methods: The reproducibility study was conducted in the city of Araraquara, São Paulo, Brazil, in April 2013, with 89 children aged 7 to 10 years who answered two QUEFAC\'s with an interval of 15 days between applications. The validity study was conducted with 167 children from two schools in the city of São Paulo, Brazil, from August to December 2013. In this, children responded to three 24-hour dietary recalls (24HR ) which was the reference method and to a QUEFAC. In both studies, the caregivers of the children answered a socioeconomic questionnaire and the child\'s ability to respond to QUEFAC was assessed. The mean difference for paired samples (Wilcoxon and paired t test), the intraclass correlation coefficient, the weighted kappa and the analysis of Bland- Altman were used to assess the reproducibility and the validity. Results: Fifty five percent of children had their ability to answer the questionnaire considered good, very good or excellent in all the aspects. In the reproducibility study, we observed a significant difference between the means for all nutrients of the two QUEFAC, the intraclass correlation coefficient ranged from 0.12 to 0.54, the weighted kappa values ranged from 0.01 to 0.39. The Bland-Altman plots showed random distribution for all nutrients. In the validity study of the entire sample, we observed difference in means for all nutrients, except for energy and zinc, the intraclass correlation coefficient ranged from 0 to 0.37, the weighted kappa values ranged from 0 to 0.27. The Bland-Altman plot showed a random distribution of data for lipids, carbohydrates, calcium, phosphorus, sodium, zinc, vitamin B1, vitamin B2, niacin, vitamin C, retinol and saturated fat. The assessment of the validity stratified by sex, age and socioeconomic status showed similar results. Conclusion: the QUEFAC was not valid for the evaluation of habitual intake of the last three months for children aged 7 to 10 years living in the city of Sao Paulo and had moderate reproducibility for energy, protein, calcium, phosphorus, iron , potassium, magnesium and vitamin B2.
83

Reprodutibilidade de um índice para diagnóstico e avaliação da atividade de lesões de cárie dentária na dentição decídua / Reliability of a caries diagnostic and activity assessment criteria in the primary dentition

Mariana Canano Séllos 21 January 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do presente estudo clínico é verificar a reprodutibilidade intra e interexaminadores de um critério de diagnóstico de cárie dentária (Nyvad et al. 1999) aplicado na dentição decídua, e avaliar o tempo médio necessário para a realização do exame clínico utilizando o referido critério. O mesmo é baseado na combinação de métodos visuais e táteis e propõe a diferenciação entre lesões ativas e inativas, tanto para lesões cavitadas quanto para não cavitadas. A amostra total consistiu de 80 crianças de três a sete anos de idade, de ambos os sexos, estudantes do Centro Educacional Terra Santa (Petrópolis/ RJ). Os responsáveis assinaram um termo de consentimento livre e esclarecido e o trabalho foi aprovado pelo Comitê de Ética em Pesquisa do HUPE-UERJ. Os exames foram realizados após escovação supervisionada, em consultório odontológico sob iluminação artificial, após 3-5s de secagem com ar comprimido, por dois examinadores treinados pelas autoras do índice e calibrados. As concordâncias intra e interexaminadores foram avaliadas pelo percentual de concordância (%) e pelo teste kappa (k), considerando a superfície dentária como unidade de análise e os seguintes pontos de corte: 1) hígida versus cariada; 2) ativa versus inativa; 3) descontinuidade versus hígida; e 4) cavitada versus hígida. O % e o valor de k para confiabilidade interexaminadores para cada ponto de corte foram: 1) % = 0,97 e k = 0,82 (IC: 0,80 - 0,85); 2) % = 0,98 e k = 0,80 (IC: 0,76 - 0,83); 3) % = 0,99 e k = 0,90 (IC: 0,88 - 0,93); 4) % = 99,0 e k = 0,95 (IC: 0,92 - 0,97). O % e o valor de k para confiabilidade intraexaminador para cada ponto de corte foram: 1) % = 0,98 e k = 0,86 (IC: 0,84 - 0,86); 2) % = 0,99 e k = 0,86 (IC: 0,83 - 0,89); 3) % = 0,99 e k = 0,94 (IC: 0,92 - 0,96); 4) % = 0,99 e k = 0,98 (IC: 0,96 - 0,99). O maior % de discordância (65,3% - 158/242) concentrou-se na diferenciação entre supefícies hígidas e lesões não cavitadas: 33,5% (81/242) entre superfície hígida e lesão não cavitada inativa; 26,0% (63/242), entre superfície hígida e lesão não cavitada ativa; e 5,8% (14/242), entre lesão não cavitada ativa e lesão não cavitada inativa. O tempo necessário para realização do exame clínico foi em média 226,5s (128,53). Conclui-se que o índice apresentou reprodutibilidade variando de substancial à quase perfeita e um tempo de exame viável, mostrando-se consistente e reproduzível para a realização de estudos clínicos de cárie dentária na dentição decídua. / The aim of the present clinical study was to evaluate the inter-and intra-examiner reliability of a caries diagnostic criteria (Nyvad et al. 1999) in the deciduous dentition and to assess the mean examination time. This criteria is based on a combination of visual and tactile methods and differentiates between active and inactive caries lesions at both cavitated and non-cavitated levels. A sample of 80 children aged 3 to 7 years-old, students from Centro Educacional Terra Santa school (Petrópolis/ RJ), participated in the study. Parents signed informed consent forms and the study was approved by the Committee for Ethics in Research, Rio de Janeiro State University. Examinations were performed after supervised toothbrushing, under standardized conditions, using dental chair, artificial light and compressed air, by two calibrated examiners previously trained by two of the criterias authors. The inter-and intra-examiner reliability was expressed as percentage agreement (%) and Cohens kappa (k) at tooth surface level, using the following cut-off points: 1) sound versus diseased; 2) active versus inactive; 3) discontinuity level versus sound; e 4) cavity level versus sound. The % and the k value for inter-examiner for each cut-off points were: 1) % = 0.97 and k = 0.82 (CI: 0.80 0.85); 2) % = 0.98 and k = 0.80 (CI: 0.76 0.83); 3) % = 0.99 and k = 0.90 (CI: 0.88 0.93); 4) % = 99.0 and k = 0.95 (CI: 0.92 0.97). The % and the k value for intra-examiner for each cut-off points were: 1) % = 0.98 and k = 0.86 (CI: 0.84 0.86); 2) % = 0.99 and k = 0.86 (CI: 0.83 0.89); 3) % = 0.99 and k = 0.94 (CI: 0.92 0.96); 4) % = 0.99 and k = 0.98 (CI: 0.96 0.99). The majority of disagreements (65,3% - 158/242) were concentrated in sound and non-cavitated surfaces: 33,5% (81/242) in sound and non-cavitated inactive, 26,0% (63/242) in sound and non-cavitated active and 5,8% (14/242) in non-cavitated active and inactive. The mean examination time was 226,5s (128,53). It can be concluded from the present data that Nyvads caries diagnostic criterion showed substantial to almost perfect reliability and suitable examination time, being consistent and reliable for dental caries clinical studies in deciduous teeth.
84

Reprodutibilidade intra e interavaliador na avaliação funcional do quadril

Torresan, Anna January 2017 (has links)
A avaliação da articulação do quadril é considerada desafiadora e medidas reprodutíveis são fundamentais para construir uma prática baseada em evidências. O objetivo da presente dissertação de Mestrado foi avaliar a reprodutibilidade intra e interavaliador do teste de força máxima isométrica com dinamômetro manual, da avaliação fotogramétrica e goniométrica da amplitude de movimento (ADM) e da medida do deslocamento angular do quadril 2-D em vídeo por meio do teste de agachamento unipodal em sujeitos saudáveis. No Capítulo I, por meio de uma ampla revisão de literatura, percebemos a existência de divergências no que diz respeito à avaliação do quadril, uma vez que não foi observada uma avaliação sistematizada envolvendo as medidas mais comumente indicadas na prática clínica. O capítulo II avaliou a reprodutibilidade intra e interavaliador por três avaliadores para os desfechos força muscular por dinamometria manual (rotadores internos (RI) e externos (RE), adutores (ADU) e abdutores (ABD) e flexores (FLX) e extensores (EXT)), ADM do quadril por goniometria (FLX ativa (ATI) e passiva (PAS); RE ATI e PAS e os movimentos de rotação interna bilateral (RI BIL) e EXT ativas e fotogrametria (RE e RI BIL de forma ativa ATI e PAS e deslocamento angular durante o agachamento unipodal para as variáveis flexão de joelho no plano sagital (FLX JOE PS), báscula pélvica (BASC), adução do quadril (ADU QUA) e adução do joelho (ADU JOE) Todas as variáveis foram avaliadas nos lados direito (DIR) e esquerdo (ESQ). Vinte sujeitos do sexo masculino (27,0 ± 4,9 anos; massa corporal: 80,07 ± 13,13 kg; estatura: 1,78 ± 0,06 cm; dominância direita [n=18, 90%]), foram submetidos a dois dias de avaliação da funcionalidade do quadril por três avaliadores: (1) dia 1 pelo avaliador 1; (2) dia 2 por três avaliadores (avaliador 1, 2 e 3, com 30 minutos de intervalo entre as avaliações). A análise dos dados foi realizada no software SPSS v. 20.0, por meio de estatística descritiva (média, DP - desvio padrão) e inferencial (ICC – intraclass correlation coefficient; SEM – Standard error measurement; MDC – minimal detectable change = 1,96*SEM) (α<0,05). O teste t pareado foi utilizado para examinar se houve diferença sistemática entre o teste e re-teste e a ANOVA One-Way para medidas repetidas foi utilizada para comparar as médias entre os avaliadores. Havendo efeito principal significativo, foi utilizado um teste post-hoc de Bonferroni para comparações múltiplas (p≤0,05). Para as medidas de força de todos os grupos musculares, a reprodutibilidade intra-avaliador revelou valores de ICC classificados como excelentes para todos os grupos musculares avaliados (ICC≥0,89; p<0,001) com valores médios de SEM = 11,83 ± 2,94 N e MDC = 23,21 ± 5,80 N A reprodutibilidade interavaliador revelou valores de ICC excelentes para todos os grupos musculares (ICC≥0,90; p<0,001) com valores médios de SEM = 10,69 ± 1,96 N e MDC = 20,93 ± 3,86 N. Em relação às medidas de ADM obtidas por goniometria, a reprodutibilidade intravaliador foi classificada como excelente (ICC≥0,77; p<0,05) com valores médios de SEM = 2,67 ± 0,54°e MDC = 5,21 ± 1,04°, com exceção da ADM de FLX PASS DIR (ICC≥0,68; p=0,100), EXT ATI DIR (ICC=0,73; p=0,030) e ESQ (ICC=0,66; p=0,011), consideradas satisfatórias. A reprodutibilidade interavaliador dos valores de ADM por goniometria foram classificadas como excelentes na comparação interavaliadores (ICC≥0,77; p<0,001) com valores médios de SEM = 5,22 ± 1,04° e MDC = 6,95 ± 6,34°, com exceção dos valores de ICC da variável EXT ESQ ATI considerada satisfatória (ICC=0,62), Quanto à ADM obtidas através da fotogrametria, as medidas apresentaram valores de ICC para reprodutibilidade intra e interavaliador classificados como excelentes (ICC≥0,93 e ≥0,96, respectivamente; p<0,001) e valores médios de SEM = 1,94 ± 0,39°e MDC = 3,8 ± 0,76° (intra-avaliador) e de 1,43 ± 0,18° e 2,80 ± 0,34° (interavaliador), respectivamente Para os valores de deslocamento angular durante o agachamento unipodal, com exceção dos valores de ICC da variável de ADU QUA ESQ (ICC=0,62; p=0,021), classificada como satisfatória, todos os valores de ICC foram considerados excelentes para todas as medidas de reprodutibilidade intra-avaliador (ICC≥0,82; p<0,001), com valores médios de SEM = 2,55 ± 1,01° e MDC = 4,98 ± 1,99°. Para reprodutibilidade interavaliador, todos os valores de ICC foram classificados como excelentes (ICC≥0,87; p<0,001), com valores médios de SEM = 1,78 ± 0,65° e MDC = 3,48 ± 1,26°. Os resultados demonstram que os testes avaliados podem ser usados tanto na prática clínica quanto em pesquisas, pois apresentam medidas confiáveis, uma vez que sua reprodutibilidade intra e interavaliador são satisfatórias/excelentes. Entretanto, aprimoramentos nas técnicas utilizadas são necessários a fim de melhorar a reprodutibilidade e reduzir os erros de medida na avaliação do quadril. / The evaluation of the hip joint continues to be considered challenging and reproducible measures are key to building an evidence-based practice. The objective of this Master's thesis was to evaluate the intra and inter-rater reproducibility of the isometric maximum strength test with manual dynamometer, the photogrammetric and goniometric evaluation of range of motion (ROM) and the 2-D video analysis of single leg squat test in healthy subjects. In Chapter I, through a large literature review, we noticed the existence of disagreements regarding hip assessment, since a systematized evaluation involving the measures most commonly indicated in clinical practice was not observed. Chapter II evaluated the intra and inter-rater reproducibility by three evaluators for manual dynamometry: internal and external rotators (IR and ER), adductors (ADD) and abductors (ABD), flexors (FLX) and extensors (EXT ), hip ROM by goniometry (active extension and bilateral internal rotation; active and passive flexion and external rotation); and by photogrammetry (active and passive IR and ER) and angular displacement during single leg squat (knee flexion in the sagittal plane (KFLX SP), pelvic drop (PD), hip adduction (HADD) and knee adduction (KADD). All variables were evaluated on the right (R) and left (L) sides Twenty male subjects (27.0 ± 4.9 years, body mass: 80.07 ± 13.13 kg, height: 1.78 ± 0.06 cm, right dominance [n = 18, 90%]) were submitted to two days of evaluation of hip functionality by three evaluators: (1) day 1 by the evaluator 1; (2) day 2 by three evaluators (evaluator 1, 2 and 3, with a 30-minute interval between evaluations). Data analysis was performed in SPSS v. 20.0, by means of descriptive statistics (mean, SD - standard deviation) and inferential (ICC - intraclass correlation coefficient; SEM) (α<0.05). The paired t-test was used to examine whether there was a systematic difference between the test and re-test and the One-Way ANOVA for repeated measures was used to compare the means among the evaluators. For the strength measurements of all muscle groups, the intra-rater reproducibility revealed values classified as excellent for all muscle groups evaluated (ICC≥0.89; p<0.001) with SEM values = 11.83 ± 2.94 N and MDC = 23.21 ± 5.80 N. The inter-rater reproducibility revealed excellent ICC values for all muscle groups (ICC≥0.90, p<0.001) with SEM values = 10.69 ± 1.96 N and MDC = 20.93 ± 3.86 N Regarding the measurements of ROM obtained by goniometry, the intra-rater reproducibility was classified as excellent (ICC≥0.77, p<0.05) with mean values of SEM = 2.67 ± 0.54° and MDC = 5.21 ± 1.04°, with the exception of passive right flexion (ICC=0.68; p=0.100), active right extension (ICC=0.73; p=0.030) and active left extension (ICC=0.66; p=0.011), considered satisfactory. The inter-rater reproducibility of ROM values by goniometry were classified as excellent in the inter-rater comparison (ICC≥0.77; p<0.001) with SEM values = 5.22 ± 1.04° and MDC = 6.95 ± 6.34, with the exception of ICC values of the active left extension considered satisfactory (ICC=0.62). Regarding the ROM obtained through photogrammetry, the measurements presented ICC values for intra and inter-rater reproducibility classified as excellent (ICC≥0.93 and ≥0.96, respectively; p<0.001) and mean values of SEM = 1.94 ± 0.39° and MDC = 3.8 ± 0.76° (intra-rater) and 1.43 ± 0.18° and 2.80 ± 0.34° (inter-rater), respectively. For the values of angular displacement during unipodal single leg squat, except for the ICC values of the left hip adduction variable (ICC=0.62; p=0.021), classified as satisfactory, all were considered excellent for all measures (ICC≥0.82, p<0.001), with SEM values = 2.55 ± 1.01° and MDC = 4.98 ± 1.99°. For inter-rater reproducibility, all ICC values were classified as excellent (ICC≥0.87; p<0.001), with SEM values = 1.78 ± 0.65° and MDC = 3.48 ± 1.26°. The results demonstrate that the tests evaluated can be used both in clinical practice and in research, since they present reliable measures, since their intra and inter-rater reproducibility are satisfactory/excellent. However, improvements in the techniques used are necessary to improve reproducibility and reduce measurement errors in hip assessment.
85

Equivalência de mensuração e operacional da versão brasileira do Physical Activity Checklist Interview em crianças / Measurement and operational equivalence of the Brazilian version of the Physical Activity Checklist Interview in children

Fernando Adami 30 June 2011 (has links)
Introdução: Há escassez de questionários que permitam a aferição de atividade física em crianças brasileiras. O Physical Activity Checklist Interview (PACI), desenvolvido em crianças americanas, permite aferir atividade física do dia anterior. Seguindo procedimento de adaptação transcultural, o PACI foi adaptado à cultura brasileira com apreciação das equivalências conceitual, de itens e semântica, resultando na versão em português denominada Lista de Atividades Físicas (LAF). Objetivos: i) identificar questionários para aferição de atividade física em crianças; ii) avaliar as equivalências de mensuração e operacional do LAF. Métodos: Tese composta por três manuscritos. O primeiro apresenta revisão sistemática de questionários de aferição de atividade física para uso em crianças publicados nas bases PubMed, LILACS e SportDiscus no período de 1993 a 2006. O segundo avalia a confiabilidade do LAF utilizando dados de 83 escolares da Escola de Aplicação da USP (EAUSP) com idade entre 7 e 10 anos. Utilizaram-se nas análises os coeficientes de correlação intraclasse (CCI) e de concordância de Lin, e a estratégia de Bland & Altman. O último manuscrito avalia a validade, por meio da correlação entre os dados provenientes do LAF e os de acelerômetros, e a equivalência operacional do LAF, por meio de dados relativos à aplicação do instrumento, e inclui 118 escolares de 7 a 10 anos da EAUSP. Resultados: Manuscrito 1: dezoito questionários que preencheram os critérios de elegibilidade foram descritos segundo suas características, forma de quantificação da atividade física, propriedades psicométricas e aspectos operacionais. Manuscrito 2: pela análise de confiabilidade, observou-se que os índices de atividade física do LAF apresentaram limite inferior do CCI entre 0,84 a 0,96. A precisão e acurácia em relação à concordância perfeita variaram, respectivamente, de 0,83 a 0,97 e de 0,99 a 1. Manuscrito 3: Os valores de correlação entre os resultados provenientes do questionário e do acelerômetro variaram de 0,34 a 0,40. O LAF superestimou o tempo em ativade física moderada a vigorosa quando comparado ao acelerômetro. A duração média da entrevista foi de 24 minutos (desvio padrão = 5 min) e o item da entrevista com pior resultado foi a habilidade em estimar tempo (ruim ou regular em 24,8 por cento das entrevistas). Conclusões: O PACI, identificado a partir de revisão sistemática da literatura, é apresentado de modo adaptado à cultura brasileira seguindo modelo de adaptação transcultural que resultou na Lista de Atividades Físicas - LAF. A utilização do instrumento em estudos epidemiológicos, no entanto, deve ser vista com cautela / Background: There is a lack of questionnaires that allow the assessment of physical activity in Brazilian children. The Physical Activity Checklist Interview (PACI), developed in American children, enables the assessment of physical activity of the previous day. According to the cross-cultural adaptation procedures, the PACI was adapted to Brazilian culture with evaluation of the conceptual, item and semantic equivalence, obtaining the Portuguese version called Lista de Atividades Físicas (LAF). Objectives: i) to identify questionnaires to assess physical activity in children; ii) to assess the measurement and operational equivalence of the Lista de Atividades Físicas. Methods: This thesis consists of three manuscripts. The first presents a systematic review of physical activity questionnaires for use in children published in PubMed, LILACS and SportDiscus from 1993 to 2006. The second assesses the reliability of LAF and includes data from 83 school children aged between 7 and 10 years from Escola de Aplicação da USP (EAUSP). Intraclass correlation coefficient (ICC), Lins concordance correlation coefficient and Bland & Altmans proposal were used in the analysis. The last manuscript assesses the validity of the questionnaire using the correlation between data from LAF and accelerometers, and the operational equivalence of LAF using data concerning the application of the instrument, and includes data from 118 school children aged between 7 and 10 years from EAUSP. Results: Manuscript 1: Eighteen questionnaires met the eligibility criteria and are presented according to their characteristics, physical activity measurement methods, psychometric properties and operational aspects. Manuscript 2: In relation to the reliability analysis, the lower limits of the ICCs varied from 0.84 to 0.96. Precision and agreement varied between 0.83 and 0.97 and between 0.99 and 1, respectively. Manuscript 3: The correlation between the results from the questionnaire and from accelerometer ranged from 0.34 to 0.40. It was found that LAF overestimated the time of moderate to vigorous physical activities when compared to the accelerometer. In terms of operational aspects, mean duration of the interview was 24 minutes (minimum = 13, maximum = 41, standard deviation = 5 min). The interview item showing the poorest result was the ability to estimate the time (poor or fair in 24.8 per cent of the interviews). Conclusion: The PACI, identified from a systematic review, is presented in a way adapted to Brazilian culture following the model of cross-cultural adaptation that resulted in Lista de Atividades Físicas - LAF. However, its use in epidemiological studies must be viewed with caution
86

Avaliação da confiabilidade interexaminador dos testes sensoriais quantitativos em estruturas mastigatórias / Evaluation of interrater reliability of quantitative sensory testing in the masticatory structures

Everardo Napoleão Santana de Araújo Junior 29 March 2018 (has links)
Este estudo estimou a confiabilidade interexaminador e a concordância da avaliação somatossensorial realizada na região do músculo masseter e da articulação temporomandibular (ATM) em um grupo de voluntários saudáveis do sexo feminino e masculino. Quarenta participantes saudáveis (20 homens e 20 mulheres) foram avaliados em duas sessões por dois examinadores diferentes. Os testes aplicados foram limiar de detecção ao frio (CDT, siglas em inglês), limiar de detecção ao calor (WDT), limiar sensorial térmico (TSL), limiar de dor ao frio (CPT), limiar de dor ao calor (HPT), limiar de detecção mecânica (MDT), limiar de dor mecânica (MPT) Razão da somação temporal (WUR) e o limiar de dor a pressão (PPT). ANOVA, coeficiente de correlação intraclasse (ICC) e erro padrão de mensuração (SEM) foram computados ( = 5%). O intervalo de confiança de 95% sem sobreposição (IC 95%) dos valores de ICC foi considerado significativamente diferente. Setenta e sete por cento dos valores de ICC de todas as medidas do QST variaram entre razoável a excelente (ICCs: 0,47-0,97). No entanto, a confiabilidade do WDT, TSL e HPT do masseter foi significativamente maior do que da ATM, enquanto que a confiabilidade de MDT da ATM foi maior do que do músculo masseter. Além disso, a seguinte combinação de teste/sítio apresentou os menores valores de ICC nas mulheres: HPT e MDT da ATM e MPT de ambos os sítios ATM e masseter. Para o erro padrão de mensuração, os maiores valores foram apresentados no CPT e MPT. A avaliação somatossensorial geral das estruturas de mastigatórias realizadas por dois examinadores pode ser considerada suficientemente confiável para discriminar os participantes. No entanto, as possíveis influências do sitio e do sexo nos parâmetros de reprodutibilidade devem ser levadas em consideração para uma interpretação e aplicação clínica apropriadas. / This study estimated the interrater reliability and agreement of the somatosensory assessment performed at masseter and temporomandibular joint (TMJ) region in a group of healthy female and male participants. Forty healthy participants (20 men and 20 men) were evaluated in two sessions by two different examiners. Cold detection threshold (CDT), warm detection threshold (WDT), thermal sensory limen (TSL), cold pain threshold (CPT), heat pain threshold (HPT), mechanical detection threshold (MDT), mechanical pain threshold (MPT), wind-up ratio (WUR) and pressure pain threshold (PPT) were assessed on the skin overlying masseter body and TMJ. Mixed ANOVA, Intraclass Correlation Coefficients (ICC) and standard error of measurement (SEM) were applied to the data (=5%). Non-overlapping 95% confidence intervals (95% CI) of ICC values were considered significantly different. The ICC values of 77% of all QST measurements were considered fair to excellent (ICCs: 0.47-0.97). However, the reliability of WDT, TSL and HPT of masseter was significantly higher than TMJ, whereas the MDT reliability of TMJ was higher than masseter. In addition, the following combination of test/sites presented significantly lower ICCs for women: HPT, MDT of TMJ and MPT of both TMJ and masseter. Finally, the highest SEM values were presented for CPT and MPT. The overall somatosensory assessment of the masticatory structures performed by two examiners can be considered sufficiently reliable to discriminate participants. Nevertheless, possible site and sex influences on the reproducibility parameters should be take into account for an appropriate interpretation and clinical application.
87

Avaliação da reprodutibilidade dos parâmetros de adequação da hemodiálise crônica / Evaluation of reproducibility of adequacy Parameters in chronic hemodialysis

Manente, Marislei January 2002 (has links)
Justificativa: Doses inadequadas de diálise estão associadas a maior morbidade e mortalidade em pacientes com uremia terminal em tratamento hemodialítico. Atualmente os métodos mais utilizados para medir a adequação da hemodiálise baseiam-se no cálculo da depuração fracional de uréia (Kt/V) e da taxa de redução da uréia (URR). Nesse estudo avaliou-se a reprodutibilidade do Kt/V e da URR e analisou-se o número aceitável de medidas mensais destes parâmetros para determinar de forma fidedigna a adequação da hemodiálise. Métodos: Avaliamos 43 pacientes clinicamente estáveis, em cinco sessões de hemodiálise (sessões 1 a 5), durante três semanas. Três diálises consecutivas na primeira semana (sessões 1, 2, 3) e duas sessões de meio de semana, nas duas semanas subseqüentes (sessões 4 e 5). Resultados: Não houve diferença entre a média dos Kt/Vs obtidos em diálises seqüenciais (1, 2 e 3) comparada a média dos Kt/Vs obtidos em diálises no meio da semana (2, 4 e 5). O mesmo aconteceu com a URR e com os coeficientes de variação do Kt/V e da URR. Também não encontramos diferença entre uma medida mensal (Kt/V 2) e três medidas mensais (média dos Kt/Vs 2, 4 e 5). O mesmo ocorreu com a URR. A diferença entre o Kt/V 2 e a média dos Kt/Vs 2, 4 e 5 foi de – 0,02 unidades e entre a URR 2 em relação a média das URRs 2, 4 e 5 foi de – 0,5%. Além disso, se fizermos apenas uma medida mensal (Kt/V 2) 80% dos pacientes estarão a uma distância de no máximo 0,16 unidades abaixo da média dos Kt/Vs 2, 4 e 5 e no máximo 0,12 unidades acima. Em relação a URR 80% dos pacientes estarão a uma distância de no máximo 4,37% abaixo da média das URRs 2, 4 e 5 e no máximo 3,37% acima. O grau de concordância entre o Kt/V 2 e a média dos Kt/Vs 2, 4 e 5 é bom para pontos de corte do Kt/V igual ou superior a 1,3. No caso da URR a concordância é boa para pontos de corte acima de 65%. Conclusão: Concluímos que nesta população de pacientes clinicamente estáveis os parâmetros de adequação da hemodiálise mostraram-se reprodutíveis não havendo necessidade de aumentar o número de medidas mensais da quantidade de diálise ofertada. / Background: Inadequate doses of dialysis are associated with higher morbidity and mortality rates for end-stage renal disease (ESRD) patients undergoing hemodialysis treatment. Most methods aimed at measuring dialysis adequacy use the calculation of fractional clearance of urea (Kt/V) and urea reduction ratio (URR). This study evaluates the reproducibility of Kt/V and URR and analyzes the acceptable number of monthly measurements of these parameters to determine hemodialysis adequacy. Methods: We evaluated 43 clinically stable patients in five hemodialysis sessions (1 to 5) along three weeks. Three consecutive sessions were carried out in the first week (1, 2, 3), while the two other studied sessions were carried out in the middle of the week at weekly intervals (4, 5). Results: There was no difference between mean Kt/V in sessions 1, 2, and 3 and in sessions 2, 4, and 5. The same was observed for URR and the coefficients of variation for Kt/V and URR. Either differences were found between one monthly measurement (2) or three monthly measurements (mean of 2, 4, and 5) for Kt/V and URR. The difference between Kt/V 2 and the arithmetic mean of Kt/Vs 2, 4, and 5 was – 0.02 units, and between URR 2 and the mean of URRs 2, 4, and 5 was – 0.5%. When only one monthly measurement (Kt/V 2) was considered, 80% of the patients presented ≤0.16 unit below or ≤0.12 above the mean of Kt/Vs 2, 4, and 5. For URR, 80% of patients presented ≤4.73% below or ≤3.37% above the arithmetic mean of URRs 2, 4, and 5. The degree of agreement between Kt/V 2 and the mean of Kt/Vs 2, 4 and 5 is good for Kt/Vs of 1.3 or higher. URR agreements are good for URR of 65% or higher. Conclusion: In this population, hemodialysis adequacy parameters were reproducible, and an increase in the number of monthly measurements seems not to be necessary.
88

Avaliação da qualidade de vida em cardiopatia isquêmica : validação de instrumentos para uma população brasileira

Franzen, Elenara January 2005 (has links)
Objetivos: validar versões em português do Short Form Health Survey (SF-36) e do Seattle Angina Questionnaire (SAQ) para avaliação de qualidade de vida em pacientes brasileiros com cardiopatia isquêmica. Métodos: estudo transversal com instrumentos traduzidos e aplicados em dois grupos: em 200 pacientes ambulatoriais com cardiopatia isquêmica estável em dois momentos, com intervalo de 14 dias; e em 50 pacientes antes e 30 dias após a angioplastia. Classe funcional foi avaliada pelo Specific Activity Scale. Testes de correlação intraclasse, Cronbach α e Wilcoxon foram utilizados. Resultados: os participantes dos dois grupos apresentaram características clínicodemográficas semelhantes, sendo a taxa de resposta de 78% e 76% no reteste. Reprodutibilidade dos instrumentos (coeficiente α de Cronbach) variou de 0,70 a 0,90 e 0,62 a 0,79 para os domínios do SF-36 e do SAQ, respectivamente. Estabilidade dos instrumentos em 14 dias (coeficiente de correlação intraclasse) foi >0,68 e >0,49 para os domínios do SF-36 e SAQ. No quesito responsividade, o SF-36 demonstrou melhora nos domínios capacidade funcional (10,5), dor (16,5), vitalidade (13,5), aspecto social (10,1) e saúde mental (9,8); e no SAQ, nos domínios estabilidade (41,1) e freqüência (27,3) da angina e percepção da doença (12,0). Os domínios do SF-36 e do SAQ, exceto um, foram consistentemente relacionados à classe funcional. Conclusão: as versões traduzidas dos instrumentos mostraram desempenho adequado sem diferenças entre si, sugerindo serem reprodutíveis, responsivas e válidas para a avaliação da qualidade de vida em pacientes com cardiopatia isquêmica no Brasil. / Objectives: To validate Portuguese-language versions of the Short Form Health Survey (SF-36) and of the Seattle Angina Questionnaire (SAQ), for the evaluation of quality of life in Brazilian patients with ischemic heart disease. Methods: Cross-sectional study using instruments translated and applied to two groups: 200 outpatients with stable ischemic cardiomyopathy at two points in time- 14-day interval; and 50 patients pre and 30 days post angioplasty. Functional class was evaluated by the Specific Activity Scale. Intra-class correlation, Cronbach’s alpha and Wilcoxon tests were used. Results: The participants in both groups presented similar clinical-demographic characteristics, and the rate of response in the retest was 78% and 76%. Reproducibility of the instruments (Cronbach alpha coefficient) varied from 0.70 to 0.90 and 0.62 to 0.79 for the SF-36 and SAQ domains, respectively. Stability of instruments in 14 days (intraclass correlation coefficient) was ≥0.68 and ≥0.49 for the SF-36 and SAQ domains. For the responsiveness item, SF-36 showed improvement in the domains physical functioning (10.5), bodily pain (16.5), vitality (13.5), social functioning (10.1) and mental health (9.8); and in SAQ in those concerning stability (41.1) and frequency (27.3) of angina and disease perception (12.0). The SF-36 and SAQ domains except one were consistently related to functional class. Conclusion: The translated versions of the instruments showed an adequate performance without differences amongst them, suggesting that they are reproducible, responsive and valid to evaluate quality of life in ischemic heart disease patients in Brazil.
89

Avaliação da estabilidade das cinturas escapular e lombo-pélvica através do upper body test : reprodutibilidade e efeitos de exercícios agrupados e alternados no treinamento funcional

Fontes, Alan dos Santos 30 August 2017 (has links)
Limitations are found when verifying tests for stability of the shoulder and pelvic girdle, which compromises the ability to evaluate this variable for professional practice and scientific research. Proper core stability capability is important by preventing low back pain and improving performance in sports. The aim of this master thesis was to evaluate the reproducibility of the Upper Body Test and to apply it to evaluate the stabilization capacity of the shoulder and pelvic girdle after a training program with functional characteristics, performed with two methodologies of movement organization. For this, a study was carried out to evaluate the reproducibility of the test in young adults, during three days of evaluations, through the intraclass correlation coefficient, coefficient of variation and graphical analysis of Bland-Altman, as well as identification of the minimum detectable change of the instrument. A controlled clinical trial was then conducted with three groups: grouped training group, alternate training group, and control group. The groups performed a training period with functional characteristics, with the same training load, differentiated by the methodological organization of the training way. One group trained in a grouped manner, one alternately according to functional movement patterns, and the control group did not perform any type of training. The groups were evaluated before and after 10 weeks of training through the Upper Body Test. Statistical difference was observed between the first and second test sessions, with standardization of the evaluations for the third session. Thus, the very high reproducibility (r = 0.87 to 0.94) was found between the second and third evaluations, with a low variation (3.31% to 5.91%) and agreement between the measurements obtained with the Upper Body Test. The minimal detectable difference between the patterns shows greater sensitivity to the body hemispheres (3.3 to 3.8). From the reproducibility obtained for the test and 10 weeks of training, it was verified that the group that trained in a grouped way obtained statistical improvement between the initial and final moments of the training, with a small effect size for the measurements in relation to the hemispheres Body. The group of grouped training had statistical difference in relation to the control group. Thus, it is concluded that Upper Body Test presents reliability for assessing the capacity of stabilizing the shoulder and pelvic girdle in young adults, and that the way of grouped functional training promotes an improvement in this capacity of stabilization. / A adequada capacidade de estabilidade do core é importante por prevenir dor lombar e melhorar o rendimento em esportes. Testes para verificar a estabilidade do core ganham notoriedade nos últimos anos, entretanto limitações são encontradas para os testes propostos para verificar a capacidade de estabilização das cinturas escapular e lombo-pélvica, estas consideradas parte integrante do core. O objetivo desta dissertação foi avaliar a reprodutibilidade do Upper Body Test e aplicá-lo para avaliação da estabilidade das cinturas escapular e lombo-pélvica após um programa de treinamento funcional, realizado com duas formas de organização de movimentos. Para isto, foi realizado um estudo para avaliar a reprodutibilidade do teste em 31 adultos jovens, através do coeficiente de correlação intraclasse, coeficiente de variação e análise gráfica de Bland-Altman, bem como, identificação da diferença mínima detectável do instrumento. Em seguida, foi realizado um ensaio clínico controlado com três grupos: grupo de treinamento agrupado, grupo de treinamento alternado e grupo controle. Os grupos realizaram um período de treinamento funcional, com a mesma carga e diferenciados pelo agrupamento ou alternância de ações funcionais, e o grupo controle não realizou nenhum tipo de treinamento. Os grupos foram avaliados antes e após 10 semanas de treinamento por meio do Upper Body Test. Foi observado, diferença estatística para o alcance relativo, entre a primeira e a segunda sessão de testes, com padronização dos testes para a terceira sessão. Desse modo, encontrou-se alta a muito alta reprodutibilidade (r = 0,87 a 0,94) entre a segunda e terceira avaliação, com baixa variação (3,31% a 5,91%) e concordância entre as medidas obtidas com o Upper Body Test. A diferença mínima detectável para o teste, apresenta maior sensibilidade para os hemisférios corporais (3,3 a 3,8). Obtida a reprodutibilidade do teste, e aplicadas 10 semanas de treinamento, foi constatado que o grupo de treinamento agrupado obteve melhora estatística, para a estabilidade das cinturas escapular e lombo-pélvica entre os momentos inicial e final da intervenção, com um tamanho do efeito pequeno para as medidas em relação aos hemisférios corporais. O grupo de treinamento agrupado obteve diferença em relação ao grupo controle. Assim conclui-se que Upper Body Test apresenta fiabilidade para avaliação da capacidade de estabilização da cintura escapular e lombo-pélvica em adultos jovens, e que a maneira de treinamento funcional agrupada promove melhora nessa capacidade de estabilização. / São Cristóvão, SE
90

Reprodutibilidade do teste de sobrecarga hidrica realizado em diferentes horarios do dia / Reproductility of the water drinking test performde at different times of the day

Medina, Flavio Mac Cord, 1978- 01 December 2009 (has links)
Orientadores: Jose Paulo Cabral de Vasconcellos, Vital Paulino Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-12T19:09:11Z (GMT). No. of bitstreams: 1 Medina_FlavioMacCord_M.pdf: 2280525 bytes, checksum: d64f96bf19c317e1e22a704a8562d282 (MD5) Previous issue date: 2009 / Resumo: Objetivo: Avaliar a reprodutibilidade do teste de sobrecarga hídrica (TSH) em diferentes horários em que é realizado, em pacientes com glaucoma primário de ângulo aberto (GPAA) e em indivíduos normais. Métodos: Quinze pacientes com GPAA e 30 indivíduos normais foram submetidos a três TSHs, realizados em diferentes horários do dia (às 7:00, 12:00 e 17:00), em três dias diferentes. Foram comparados os resultados dos testes em pacientes com GPAA e indivíduos normais. Foram analisadas a concordância e a correlação entre os valores de medida basal, pico e variação de pressão intra-ocular (PIO) (pico de PIO - PIO basal) nos testes realizados nos diferentes horários. Apenas as medidas do olho direito foram analisadas. Resultados: Os valores médios de medida basal, pico e variação de PIO foram significativamente maiores nos pacientes glaucomatosos que nos indivíduos normais, em todos os horários (p<0,05). A análise de Bland-Altman apresentou limites de concordância de pico e variação de PIO maiores do que o clinicamente aceitável (> 3 mmHg), apesar de o teste de Pearson demonstrar boa correlação entre os resultados. Conclusões: O TSH apresenta valores de pico e variação de Pio significativamente maiores em pacientes glaucomatosos que em indivíduos normais. Os baixos níveis de concordância entre os TSHs realizados em diferentes horários do dia sugerem uma baixa reprodutibilidade do TSH, que pode limitar sua aplicabilidade para diagnóstico e acompanhamento do glaucoma / Abstract: Purpose: To evaluate the reproducibility of the water drinking test (WDT) performed at different times of the day, in primary open angle glaucoma (POAG) patients and normal individuals. Methods: Fifteen patients with POAG and 30 normal individuals underwent three WDTs at different times of the day (7 AM, 12 PM, and 5 PM) on 3 different days. Test results in POAG patients and normal individuals were compared. Agreement and correlation of intraocular pressure (IOP) baseline levels, peak levels, and IOP change (peak IOP - baseline IOP) on tests performed at different times were evaluated. Only right eye measurements were analyzed. Results: Mean baseline IOP, peak IOP and IOP change were significantly higher in POAG patients than in normal individuals, at all time intervals (p<0.05). The Bland-Altman analysis demonstrated limits of agreement for IOP peak levels and IOP changes larger than the clinically acceptable (> 3 mmHg), even though Pearson's test revealed good correlation among the results. Conclusions: The mean IOP peak and mean IOP change observed during the WDT are significantly higher in POAG patients than in control individuals. Low levels of agreement among WDTs performed at different times of the day suggest a poor reproducibility of WDT, which may limit its applicability for the diagnosis and follow-up of glaucoma / Mestrado / Oftalmologia / Mestre em Ciências Médicas

Page generated in 0.0887 seconds