• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 4
  • Tagged with
  • 15
  • 7
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

”Vi hinner inte nästan…nånting” : En fallstudie av arbetstidens fördelning mellan arbetsuppgifter i förskolan och arbetslagets upplevelser av hur arbetstiden används.

Netscher Sundin, Ulrika January 2015 (has links)
<p>Godkännandedatum: 2015-06-07</p>
2

Ökad elproduktion från solkraft : Jämförande studie av två solcellsmoduler med olika lösningar för hantering av partiell skuggning / Increased production of electricity from solar power : Comparative study of two photovoltaic modules with different solutions for handling partial shading

Westdahl, Martin January 2015 (has links)
I en tid med allt mer påtagliga miljöhot, ökande CO2-utsläpp och stigande efterfrågan på el är det viktigt att utvecklingen av billig och effektiv förnyelsebar energi fortsätter runt om i världen för att kunna konkurrera mot billigare, icke förnyelsebara, energikällor. Ett steg i detta är att utveckla och effektivisera solkraft till den nivån att länder och företag väljer att investera i solkraft. Mer konkret kan det ske igenom utveckling av nya, mer effektiva, solcellsmoduler. I denna studie ska en ny typ av solcellsmodul, SmartPlus – utvecklat av Innotech Solar, jämföras mot deras standardmodul EcoPlus för att undersöka om den nya modulen kan bidra till högre andel solkraftsgenererad el i Sverige och där med minska CO2-utsläppen. Den nya solcellsmodulen är framtagen för att bättre kunna hantera och ta tillvara på solinstrålningen om en del av modulen utsätts för skugga, därför kommer studien simulera de båda moduler i en solpark där det sker intern skuggning mellan modulraderna. Skuggning av solcellsmoduler leder idag till stora förluster i elproduktionen på grund av nuvarande modellers konstruktion och syftet med studien är att undersöka om den nya solcellsmodulen är effektivare än den standardmodul som används för tillfället. Målet med studien är att skapa och verifiera en simuleringsmodell och simulera en solpark i Sverige där resultatets variation baseras på radavståndet mellan modulraderna och om modulerna är vertikal eller horisontellt placerade för att åstadkomma en variation av skuggning. Den solpark som ger högst elproduktion är en solpark med SmartPlus-moduler horisontell modulplacering, men då tillgången på markyta ofta en begränsande faktor bör vertikal modulplacering alltid föredras. Resultatet visar dock att i valet av modul till en solpark är inte valet mellan SmartPlus och EcoPlus den viktigaste faktorn. Även om SmartPlus genomgående har en högre elproduktion på årsbasis är skillnaden marginell till EcoPlus, däremot har faktorer som radavstånd och modulplacering en större inverkan på elproduktionen och effektiviteten i solparken. / In an era of significant environmental threats, increasing carbondioxide emissions and rising electricity demand, it is important that the development of cheap and efficient renewable energy continues around the world to compete against cheaper, non-renewable, energy sources. To do this, the development of solar power have to continute so that countries and companies choose to invest solar power insteed of non-renewable energy. More specifically, it can be done through the development of new, more efficient, solar  cells modules. In this study, a new sort of solar cell module, SmartPlus - developed by Innotech Solar, is compared to their standard module EcoPlus to investigate whether the new module may contribute to the higher proportion of solar-generated electricity in Sweden and there by reducing carbondioxide emissions. The new photovoltaic module is designed to take better advantage of the solar radiation when a portion of the module is exposed to shade, therefore will this study simulating the two modules in a solar panel plant where there is internal shading between the rows. Shading of photovoltaic modules currently leads to substantial losses in electricity generation because of the modules design and the purpose of the study is to investigate whether the new photovoltaic module are more efficient than the standard solar module that currently is in use. The aim of the study is to create and verify a simulation model and simulate a solar park in Sweden where the results variation depends on the spacing between the rows in the solar panel plant and if the modules are vertically or horizontally positioned to provide a variety of shading. The solar park that provides maximum power generation is a solar park with SmartPlus modules with horizontal position, but since the availability of land is often a limiting factor the vertical position should always be preferred. The result shows that when choosing module to a solar the choice between SmartPlus and EcoPlus is not the most important factor. Even though SmartPlus consistently has a higher electricity production on an annual basis, the difference is marginal to EcoPlus, however, factors such as row spacing and module placement have a far greater impact on electricity generation and efficiency of the solar panel plant.
3

Development of a methodology to simulate simple mismatching in photovoltaic systems

Frid, Gustav January 2015 (has links)
The currently available tools to simulate solar photovoltaic (PV) systems do not offer a reliable solution to simulate string or module level inverter systems with partial shading and modules with mismatching electrical characteristics. The available methodologies to simulate this satisfying require computational power that is not commonly available. To make it possible to simulate these kinds of systems a methodology based around the software “System Advisory Model” (SAM) is proposed. The methodology assumes that shading is binary, meaning a module can either be fully shaded or not shaded at all. Two different global IV curve models are presented and evaluated in comparison with a more detailed Matlab global IV model based on the one diode equivalent circuit. All these methodologies disregards the impact of the bypass diodes in the PV module and this is considered a significant error, which has to be quantified. It is proposed that this should be done by using the two-diode equivalent circuit instead of the one diode model. Finally the methodology is not concluded to be reliable until verified in comparison with real world data. / De för närvarande tillgängliga simuleringsverktygen för solcellssystem erbjuder inte en tillförlitlig metod för simulering av delvis skuggade system eller system med moduler med olika elektriska egenskaper. De metoder som är tillgängliga för att simulera detta tillförlitligt kräver datorkraft som inte är allmäntillgänglig. För att göra det möjligt att simulera dessa typer av system föreslås en metod baserad kring programvaran "System Advisory Model" (SAM). Metoden utgår från antagandet att skuggning är binärt, vilket innebär att en modul kan antingen vara helt skuggad eller inte skuggad alls. Två olika globala IV-modeller presenteras och utvärderas i jämförelse med en detaljerad Matlab global IV-modell baserad på enkel-diods ekvivalenta kretsen. Denna metod bortser dock från effekterna av bypass-dioderna i PV-modulen och detta antas medföra betydande fel som måste kvantifieras, detta bör då göras med hjälp av två-diods ekvivalenta kretsen. Slutligen så kan metoden inte anses pålitlig förrän den har blivit verifierad med verkliga data.
4

Maximizing performance gain of Variable Rate Shading tier 2 while maintaining image quality : Using post processing effects to mask image degradation

Lind, Fredrik, Diaz Escalante, Andrés January 2021 (has links)
Background. Performance optimization is of great importance for games as it constrains the possibilities of content or complexity of systems. Modern games support high resolution rendering but higher resolutions require more pixels to be computed and solutions are needed to reduce this workload. Currently used methods include uniformly lowering the shading rates across the whole screen to reduce the amount of pixels needing computation. Variable Rate Shading is a new hardware supported technique with several functionality tiers. Tier 1 is similar to previous methods in that it lowers the shading rate for the whole screen. Tier 2 supports screen space image shading. With tier 2 screen space image shading, various different shading rates can be set across the screen which gives developers the choice of where and when to set specific shading rates. Objectives. The aim of this thesis is to examine how close Variable Rate Shading tier 2 screen space shading can come to the performance gains of Variable Rate Shading tier 1 while trying to maintain an acceptable image quality with the help of commonly used post processing effects. Methods. A lightweight scene is set up and Variable Rate Shading tier 2 methods are set to an acceptable image quality as baseline. Evaluation of performance is done by measuring the times of specific passes required by and affected by Variable Rate Shading. Image quality is measured by capturing sequences of images with no Variable Rate Shading on as reference, then with Variable Rate Shading tier 1 and several methods with tier 2 to be compared with Structural Similarity Index. Results. Highest measured performance gains from tier 2 was 28.0%. The result came from using edge detection to create the shading rate image in 3840x2160 resolution. This translates to 36.7% of the performance gains of tier 1 but with better image quality with SSIM values of 0.960 against tier 1’s 0.802, which corresponds to good and poor image quality respectively. Conclusions. Variable Rate Shading tier 2 shows great potential in increasing performance while maintaining image quality, especially with edge detection. Postprocessing effects are effective at maintaining a good image quality. Performance gains also scale well as they increase with higher resolutions. / Bakgrund. Prestandaoptimering är väldigt viktigt för spel eftersom det kan begränsa möjligheterna av innehåll eller komplexitet av system. Moderna spel stödjer rendering för höga upplösningar men höga upplösningar kräver beräkningar för mera pixlar och lösningar behövs för att minska arbetsbördan. Metoder som för närvarande används omfattar bland annat enhetlig sänkning av skuggningsförhållande över hela skärmen för att minska antalet pixlar som behöver beräkningar. Variable Rate Shading är en ny hårdvarustödd teknik med flera funktionalitetsnivåer. Nivå 1 är likt tidigare metoder eftersom skuggningsförhållandet enhetligt sänks över hela skärmen. Nivå 2 stödjer skärmrymdsbildskuggning. Med skärmrymdsbildskuggning kan skuggningsförhållanden varieras utspritt över skärmen vilket ger utvecklare valmöjligheter att bestämma var och när specifika skuggningsförhållanden ska sättas. Syfte. Syftet med examensarbetet är att undersöka hur nära Variable Rate Shading nivå 2 skärmrymdsbildskuggning kan komma prestandavinsterna av Variable Rate Shading nivå 1 samtidigt som bildkvaliteten behålls acceptabel med hjälp av vanligt använda efterbearbetningseffekter. Metod. En simpel scen skapades och metoder för Variable Rate Shading nivå 2 sattes till en acceptabel bildkvalitet som utgångspunkt. Utvärdering av prestanda gjordes genom att mäta tiderna för specifika pass som behövdes för och påverkades av Variable Rate Shading. Bildkvalitet mättes genom att spara bildsekvenser utan Variable Rate Shading på som referensbilder, sedan med Variable Rate Shading nivå 1 och flera metoder med nivå 2 för att jämföras med Structural Similarity Index. Resultat. Högsta uppmätta prestandavinsten från nivå 2 var 28.0%. Resultatet kom ifrån kantdetektering för skapandet av skuggningsförhållandebilden, med upplösningen 3840x2160. Det motsvarar 36.7% av prestandavinsten för nivå 1 men med mycket bättre bildkvalitet med SSIM-värde på 0.960 gentemot 0.802 för nivå 1, vilka motsvarar bra och dålig bildkvalitet. Slutsatser. Variable Rate Shading nivå 2 visar stor potential i prestandavinster med bibehållen bildkvalitet, speciellt med kantdetektering. Efterbearbetningseffekter är effektiva på att upprätthålla en bra bildkvalitet. Prestandavinster skalar även bra då de ökar vid högre upplösningar.
5

Solceller utsatta för partiell skuggning : Jämförelse mellan olika systemkonfigurationer / Solar Cells Exposed to Partial Shading : Comparison of Different System Configurations

Lindborg, Jenny January 2019 (has links)
I takt med en förstärkt global uppvärmning har åtgärdsplaner skrivits om att begränsa temperaturökningen, där många länder är överens om att mängden koldioxidutsläpp måste minska. Lösningen till det anses dels som att gå från en fossilberoende energianvändning till en förnybar. Installering av solceller växer och i Sverige kan 5 – 10 % av elproduktionen förväntas komma från solkraft år 2040. Det kvarstår dock en hel del problematik kring effektförlust till följd av partiell skuggning på solceller. Idag tillverkas solpaneler med inbyggda bypass-dioder som förbättrar elproduktionen vid skugga. Forskning påstår även att skuggningsproblematik kan minskas genom att förändra konfigurationen mellan solcellspaneler. Idag sitter panelerna vanligen ihop i serie- och parallellkopplingar, men det kan finnas energivinster i att byta ut mot tvärkopplingar. Syftet med denna studie har varit att ge beslutsunderlag för investerare av solceller, som planerar att placera dem där det finns risk för att skugga kan uppstå. Målet delades in i två delar. Det fanns en experimentell del som jämförde elproduktion utan och med skugga för två olika typer av systemkonfigurationer där solpanelerna var serie-, respektive tvärkopplade. Det fanns även en simuleringsdel som beräknade producerad elenergi på årsbasis för en solpanel som var placerad intill en skorsten. Utifrån det skapades riktlinjer för hur solpaneler bör placeras för att minimera skuggproblematik av närliggande föremål som riskerar att skugga. Experimenten utfördes utomhus och till det användes 16 monokristallina solmoduler, som först sammankopplades i serie och därefter i tvärkopplingar. Systemen anslöts till en växelriktare som omvandlade från likström till växelström. Först uppmättes producerad eleffekt för systemen, varav en modul utsattes för olika skuggförsök. Därefter separerades en solmodul från anläggningen och samma skuggförsök genomfördes på modulen. Resultaten påvisade att vid solcellssystemen hade en verkningsgrad på 16 % för solinstrålning mellan 400 – 700 W/m2. För intensitet lägre än 400 W/m2 och högre än 700 W/m2 avtog verkningsgraden med 1 – 2 %. Hög solinstrålning inträffar vanligen mitt på dagen och solcellerna har troligen då en högre temperatur, vilket sänker effektiviteten. Experimenten påvisade att ju fler av en solmoduls slingor som skuggan faller på, desto lägre blir den producerade eleffekten. Även mängden skugga som drabbar panelen spelar roll. Det beror på att om skugga enbart faller på en slinga kan de övriga arbeta ostört och får därför en högre maxeffektpunkt (MPP) på IU-kurvan. Vid full skugga på en modul minskade effekten med 7,72 % för det seriekopplade systemet (S), respektive 13,87 % vid tvärkoppling (TCT). Att det tvärkopplade systemet producerar lägre effekt vid skugga beror dels på att kretsen innehåller en högre ström, troligen för hög för vad bypass-dioderna klarar av. Om strömmen i en skuggad modul leds genom dess bypass-dioder utvecklas ingen spänning i modulen. Om systemet innehåller fler parallellkopplade strängar kommer även de oskuggade strängarna att minska sin spänning, då den är identisk över hela systemet. Den tvärkopplade kretsen innehöll två parallellkopplade strängar. Känslighetsanalysen där en solmodul avlägsnades från systemet och skuggades enskilt, redovisade snarlika resultat som för systemen. Att placera skuggobjektet längre ifrån visade sig i några försök ge en högre elproduktion, då det är enbart den direkta strålningen som tas bort. Resultaten från simuleringen uttrycktes i enheten ”skuggprestanda”, som anger hur mycket en solmodul ger skuggad jämfört med vad den hade gett oskuggad. Störst betydelse för resultaten hade skorstenens höjd och hur långt ifrån skorstenen som solpanelen placeras, samt val av väderstreck. Lägst skuggprestanda blev 41 % för en seriekopplad modul. Det för en 2 m hög skorsten som placerades intill solpanelen. Resultaten påvisade att skuggprestandan avtog med en ökad höjd på skorstenen, men för en tillräckligt hög skorsten förändrades inte skuggprestandan. Genom att välja ett avstånd som var tillräckligt långt ifrån skorstenen bidrog skuggan inte lika mycket till minskning av elproduktionen. Ju mer sydligt skorstenen var placerad om panelen krävdes ett längre avstånd. Följande riktlinjer för placering av solceller intill skuggande föremål rekommenderas för att garantera att solcellerna ger minst 95 % av vad de skulle ha gjort oskuggade. För ett skuggande föremål med höjden 0,5 m bör solcellerna placeras 0,3 m ifrån föremålet. För ett skuggobjekts höjd på 2 m bör avståndet vara 2,1 m. / The effects of global warming has lead to a temperature rise in the atmosphere. Many countries have agreed to reduce the greenhouse gas emissions in order to mitigate climate change. The energy production today is highly dependent on fossil fuels and thus one solution to reduce emissions is to use more renewable resources. Solar cells are today growing on the market and in Sweden one can expect that solar energy will represent 5 – 10 % of the electricity production in year 2040. Partial shading is still a problem causing losses in the electricity production for solar cells. To reduce the losses due to shading bypass-diodes are built-in on modules. Further successful method can also be to change the interconnections among moduls in a system. At the time of writing this paper, configurations with series-parallel connections between modules are most commonly used, but during partial shading it has been shown that increasing interconnections can increase the outgoing effect. The purpose of this study was to show guidelines for the investor of solar cells, who plans an installation near objects that will creates shadows on the cells. The target consisted of two parts. First, there was an experimental objective which compared two different system configurations where the solar modules first were connected in series and thereafter in “Total Cross Tied”. The other part of the study considered a theoretical simulation to answer questions as how the energy production during a year was changed for a solar panel by placing it near a chimney. Thereafter it should also state guidelines on how to place the panel around the chimney so that the shading effects are no noticeables. The experiments were done outdoors and the system consisted of sixteen monocrystalline solar panels. First the panels were connected in series (S) and thereafter in “Total Cross Tied” (TCT). The system included also an inverter that changed direct current from the solar panels to alternating current. In the first experiment the electricity produced from the systems was measured, whereof one module was exposed to different types of shading. As a final experiment, one module was separated from the system where is was exposed to the same shading pattern as before. The results showed that the PV systems had an efficiency of 16 % for an irradiance between 400 – 700 W/m2. For lower irradiances than 400 W/m2 and higher than 700 /m2 the systems experienced a decreasing efficiency of about 1 – 2 %. A high irradiance occurs normally during the middle of the day when the solar cells have a higher temperature, which decreases the efficiency. The experiments proved that shading more cells so that current will flow through more bypass diodes resulted in a lower electricity production. For example if only one bypass diode is activated it means that the remaining cells that are not connected to that bypass diode can work freely and gets a higher maximum power point (MPP) on the IU characteristics. When a module got completely shaded it reduced the electricity output power with 7,72 % for the system with series connected modules. For the TCT-configuration the system experienced a reduction of 13,87 %. These results may be a contradiction according to previously research. A conceivable explanation is that the TCT-configuration produces higher current, which can exceed the allowed value for a functionally bypass diode. If the current in a shaded module flows through its bypass diodes it results in a short-circuit of the module so that it cannot contribute to the voltage. The more parallel PV arrays a system includes, a higher effect loss will occur since the unshaded strings may experience an identical voltage drop as the shaded one. The TCT-configuration included two strings connected in parallel. The sensitivity analysis where one module was separated from the whole system showed nearly the same results as for the whole system. Placing the shading object far away from the module resulted in a higher electricity production for some tests, as it is only the direct radiation that disappears. The simulations results were expressed in terms of “shading performance” and it showed how much a shaded solar module produced compared to an unshaded. It was shown that the parameters that had the biggest influence on the results were the height of the chimney and how far the solar module was placed with respect to the chimney. As a worst-case scenario, the shading performance was 41 % for a series-connected module. This was for a chimney with 2 m of height that placed next to the solar module. The results indicated that having a higher chimney had a decreasing effect of the shading performance for the solar module. To get a higher shading performance one can choose to place the solar cells at a larger distance from the chimney. Conclusively, placing the solar module so that the chimney is located to the south of the module the shadow will affect the panel more, and a longer distance is therefore needed. If the solar cells are located on a distance that is at least 0,3 m from a shading object with a height of 0,5 m, it means that the solar cells will produce 95 % of what that would have given unshaded. For a shading object with a height of 2 m it means that the solar cells must be placed at a distance of 2,1 m from the object.
6

Förnybar Energi : Solcellsanläggning på industribyggnad / Renewable Energy : Solar plant on industrial building

Vestlund, Tim, Andersson, Martin January 2013 (has links)
Examensarbetet har som mål att ta fram idéer om hur en solcellsanläggning kan se ut för takytorna på Holtab AB. Utvecklingen för att värna om miljön går hastigt framåt och både privatpersoner och företag har börjat att arbete med att göra sin insats för miljön. Holtab är intresserade utav att göra en insats och därför är de intresserade utav solcellstekniken och vill därför ha en undersökning om hur det skulle kunna se ut och fungera. Examensarbetet innehåller undersökningar, analyser, jämförelser och beräkningar och presenterar en idé om hur en solcellsanläggning skulle kunna tillämpas för ett optimalt effektuttag till minimal kostnad.
7

Att skugga miljörevisorer: En studie om vad de egentligen gör på jobbet

Claesson, Elisabet January 2016 (has links)
Vad gör en miljörevisor? Jag har i den här studien skuggat två miljörevisorer i sittvardagliga arbete och har på så vis fått ta del av vad en miljörevisor egentligen gör påjobbet. Genom att studera människor i yrkespraktiken kan man förstå och förklaravariationen i organisatoriska företeelser. Som teoretisk referensram har jag använtföljande analytiska begrepp: tillit, förtroende och interaktion, legitimitet samtgranskning, struktur och omdöme. Studien visar att revisorns arbete bygger mycket påtillit och förtroende och att detta skapas genom interaktion, legitimitet och struktur. / What does an auditor do? In this study, I have been shadowing two environmentalauditors in their day-to-day audit work and therefore I was able to observe what anauditor actually do at work. Studying people in their practice of work gives anunderstanding of the variety in organizational phenomenon. As theoretical frameworkI have used the following concepts: trust, faith and interaction, legitimacy and review,structure and judgement. The result shows that the auditor’s work is built on trust andfaith, which therefore are formed by interaction, legitimacy and structure.
8

Inventering av skyddsvärda ekar (Quercus robur) : En undersökning av omsättningen av skyddsvärda ekar i Kalmar kommun. / Inventory of protected oaks (Quercus robur) : A study of the turnover of protected oak trees in Kalmar Municipality.

Tapper, Hanna January 2020 (has links)
Skyddsvärda träd, speciellt ekar (Quercus spp.), är betydelsefulla både ur ett kulturellt och biologiskt perspektiv. Flera rödlistade arter som finns i Sverige är kopplade till gamla, grova ekar och tyvärr är detta ett habitat som har minskat i Sverige. Fragmentering av ekhabitat har påverkat den biologiska mångfalden hos ek-habitaten negativt. Förändrad markanvändning är en faktor som haft stor betydelse för ekbeståndens förekomst och åldersstruktur. Studier visar att beteshävd främjar utvecklingen av större ekar genom att hålla borta omgivande träd som annars skuggar ekarna. I den här studien har förekomsten av värdefulla ekar i Kalmar kommun återinventerats efter 10-20år. Syftet är att undersöka omsättningen av ekar, och vilka faktorer som påverkar rekryteringen av värdefulla ekar. Värdefulla ekar avser här stora träd med en diameter på minst 1 meter, och deras efterträdare, med en diameter på ³80 cm i brösthöjd. Resultatet visar en nettotillökningen av värdefulla ekar i Kalmar kommun under tidsperioden mellan inventeringarna. Sammanlagt påträffades 133 nya ekar. Av de totalt 222 ekar som noterats i den föregående inventeringen återfanns 215. Av de återfunna hade 24 ekar dött under perioden mellan inventeringarna. En analys av sambandet mellan ljuskonkurrens, mätt som krontäckning, och antalet döda träd visar att dödligheten av ekar ökade med en ökande täckningsgrad i trädskiktet, vilket stödjer att eken är en skuggkänslig art. Dock var ekarnas tillväxt, mätt som ökning av omkretsen, inte störst i de lägsta täckningsgraderna, vilket innebär att fler faktorer har betydelse för trädens tillväxtframgång. / Protected trees, especially oak trees (Quercus spp.), are important from a cultural and biological perspective. Several red listed species found in Sweden are linked to old oaks and unfortunately this is a habitat that has decreased in Sweden. Fragmentation of oak habitat has adversely affected the biodiversity of oak habitat. Changed land use is a factor that has had a major impact on the occurrence and age structure of oak stocks. Studies show that grazing promotes the development of larger oaks by keeping away surrounding trees that might otherwise shade the oaks. In this study, the occurrence of valuable oaks in Kalmar municipality was re-invented after 10-20 years. The purpose is to investigate the turnover of oaks, and what factors affect the recruitment of valuable oaks. Valuable oaks here refer to large trees with a diameter of at least 1 meter, and their successors, with a diameter of ³80 cm in chest height. The result shows a net increase in valuable oaks in the municipality of Kalmar during the time period between the inventories. A total of 133 new oaks were found. Of the total 222 oaks recorded in the previous inventory, 215 were found. Of the recovered, 24 oaks had died during the period between the inventories. An analysis of the relationship between light competition, measured as crown coverage, and the number of dead trees shows that the mortality of oaks increased with an increasing degree of coverage in the tree layer, which supports that the oak is a shade-sensitive species. However, the growth of the oaks, measured as an increase in the perimeter, was not greatest in the lowest coverage ratios, which means that several factors have a bearing on the tree's growth success.
9

A photovoltaic system performance Evaluation Software : For evaluation of ten unique PV-system configurations in the middle of Sweden

Sandberg, Alexander January 2014 (has links)
This thesis contains the development of a software capable of evaluating the performance of ten unique photovoltaic (PV) systems located 10 kilometers outside of Västerås, Sweden. The ten systems have different configurations according to this list: Dual-axis tracking Single-axis tracking with 30°tilt Ground mounted, free-standing with 19° tilt Ground mounted, free-standing with 41° tilt Roof mounted with 19°tilt   Each of the above configurations exist with and without installed power optimizers adding up to a total of ten unique systems. The development goal for the evaluation software is to provide the user with a variety of tools to determine which of the systems that has the best yield and performance. Integrated in the development of the software is therefore a literature study where it is investigate how photovoltaic systems operate and especially how their performance can be evaluated. Some of the frequently used parameters are; system yield, reference yield and performance ratio. The software features are focused around presenting the data collected from the PV systems in a variety of graphs. The different types of graph are designed to let the user easy compare the data between the systems and thus find how and why a particular system is performing better than the others. The software is developed in a Matlab environment and has an intuitive user interface. The thesis time-frame is too short for any conclusive result to be presented, but to showcase the software features a short-termed evaluation of the systems have been performed. The period evaluated is a three week period in the middle of May 2014. The short-termed evaluation highlights several scenarios and issues that can arise. It has been detected throughout the project that it is difficult to separate which effects that causes one system to be better than the other. Irregularities seen in the data can be caused by many factors. Some of the more evident are; installed power optimizers, differences in system configurations and shadow patterns. By using the software effects like array shading and inaccurate measurements has been discovered. / Evaluation of first MW PV plant in Sweden
10

Shape depiction using Local Light Alignment : Evaluating the shape enhancement capabilities of the Local Light Alignment technique at multiple scales / Formskildring med hjälp av Local Light Alignment : Utvärdering av den formskildringsförbättrande förmågan hos Local Light Alignment över en skal-rymd

Ahlsén, Edvard January 2023 (has links)
Local Light Alignment is a new shading based technique in the field of shape depiction, a field which concerns itself with techniques to represent and enhance the three-dimensional (3D) shape of objects in two-dimensional (2D) visual media. The main idea of Local Light Alignment is to locally adjust the incoming direction of light to create contrast in a way that enhances the perception of shape and surface detail. It is aimed at visual artists and uses a multiple scale approach, where the user can tune the enhancement of geometric shapes of different sizes. Local Light Alignment was published together with a new objective metric for measuring shape depiction called the congruence score. This thesis strives to increase knowledge about both these new techniques by investigating how varying several parameters for Local Light Alignment affect the congruence score at different scales and strengths of enhancement. The parameters investigated are the range and spatial parameters for the bilateral filter in the scale space construction as well as the enhancement strength parameter of the main Local Light Alignment algorithm. The thesis also tries to identify any common visual characteristics for images that score high, to give a better intuition of what the congruence score represents. The tests are performed using four models, each representing a different field of application. For each model, several viewpoints are tested, and for every viewpoint, 244 differently parameterized renders are produced and scored. The results notably show that the spatial and range parameters both affect controllability of the algorithm by shifting the scores toward the finer end of the scale space with higher values, without affecting the total score. The enhancement strength parameter is shown to affect the congruence score positively, but with diminishing returns as values approach 1. It is also shown by example that the images showing the largest improvement in congruence score tend to exhibit such high degrees of exaggeration that they would probably not be considered good examples of shape depiction by human standards. This is identified as an interesting area to perform subjective evaluations in future research. These investigations will be valuable to those who will create application software that features Local Light Alignment, as well as those wanting to employ the congruence score metric. / Local Light Alignment är en ny skuggningsbaserad teknik inom området formskildring, ett område som är befattar sig med olika tekniker för att förbättra den tredimensionella formåtergivningen av objekt i tvådimensionella medier. Huvudidén bakom Local Light Alignment är att lokalt justera riktningen av inkommande ljus på ett sätt som skapar ytterligare kontrast och förstärker uppfattningen av form och ytdetaljer. Tekniken riktar sig mot designers och använder sig av en flerskalig approach, där användaren kan justera förbättringen av geometriska former av olika storlekar. Local Light Alignment publicerades tillsammans med en kvantitativ metrik för att mäta formskildring, kallad ”congruence score”, eller kongruenspoängtal på svenska. Denna uppsats eftersträvar att öka kunskapen kring båda dessa nya tekniker genom att undersöka hur parameterrymden för Local Light Alignment påverkar kongruenspoängtalet vid olika skalor och förbättringsstyrkor. De undersökta parametrarna är omfångs- och spatialparametrarna som tillhör det bilaterala filtret som används i konstruktionen av skal-rymden, samt parametern för förbättringsstyrka tillhörandes den centrala delen av Local Light Alignment algoritmen. Upptatsen försöker också att identifiera gemensamma visuella uttryck för bilder som visar stor förbättring i kongruenspängtalet, för att kunna ge en intuition om vad kongruenspoängtalet representerar som modell. Studien är genomförd med 4 olika 3D-modeller, där varje modell representerar ett separat område där Local Light Alignment skulle kunna användas. För varje modell så undersöks flera åskådningsvinklar, och för varje åskådningsvinkel så produceras 244 olika parameteriserade renderingar som sedan utvärderas med kongruenspoängtal. Resultaten visar att omfångs- och spatialparametrarna båda påverkar kontrollerbarheten hos algoritmen genom att skifta massan av poäng från den grövre delen av skal-rymden, mot den finare. Detta utan att nämnvärt påverka totalpoängen. Förbättrinsstyrkeparametern visas påverkar kongruenspoängtalet positivt, men med avtagande effect då värdet närmar sig 1. Det demonstreras också visuellt hur de bilder som visar störst förbättring i kongruenspoängtal också uppvisar så höga nivåer av överdriftseffekter att de knappast kan anses vara goda exempel av förbättrad formskildring. Detta identifieras som en intressant riktning för framtida forskning med stöd av subjektiva utvärderingar.

Page generated in 0.0694 seconds