Spelling suggestions: "subject:"upplösning"" "subject:"applösning""
11 |
Höjdmodellering med laserdata : Studie av Kärsön, Ekerö med fokus på upplösning, datalagring samt programvaraLöfquist, Johanna January 2012 (has links)
The New National Elevation Model (NNH) is a new high-resolution digital elevation model (DEM) of Sweden from airborne laser scanning. It creates many new opportunities, particularly in the area of flood mapping. NNH is provided by Lantmäteriet in two formats, both in raw LIDAR (Light Detection and Ranging) data and in grid format with two meter resolution. These alternatives have advantages and disadvantages and the aim of this thesis research is to identify these. One of the focuses of the study is data storage and thus data structure analysis, resolution and storage facilities. The research questions are: Why and in what context the different NNH-products from the National Land Survey are used (DEM 2+ or point cloud)? What constraints and opportunities are created by the different options, mainly in terms of different software, resolution, and data storage? The study area is Kärsön in Ekerö municipality located in Stockholms län and has an approximate area of 25 square kilometers. The study is divided into two parts. The first objective is to identify the consequences of using different software to create DEM from pointcloud compared to the DEM2+ model. Height models with a two meter resolution are created in FME and ArcGIS. The models are then compared with the grid from Lantmäteriet, created in TerraScan. The second objective is to examine the impact of the change in resolution, both the storage aspect and both the accuracy aspect. Inverse Distance Weighted (IDW) is an interpolation method which in previous studies proved to have the best results on high resolution LIDAR data. This model was tested and compared with a model from FMEs built-in function and the model from Lantmäteriet wich are based on triangulation (also proved a good method in previous studies). The grid created in TerraScan has good properties such as accuracy. The results show that the built-in ArcGIS model is not sufficient for the purposes of the model. Flood mapping requires continuous surfaces and the model lacks large areas of data. However, there are other aspects such as the break lines, these cannot be added to the TerraScan model or in the IDW but in the FME-modeler it is possible. In addition, it is not possible to edit the model that is delivered from Lantmäteriet. If there are outliers in the data, they will have much impact on the result. With a model created from the point cloud it is easy to remove these outliers. Increased resolution gives a quadratic increase in storage space so it is considered important not to use a resolution that is not really necessary. If the purpose of the analysis requires higher resolution than two meters it is possible to achieve higher accuracy for areas with high point density. The raw data format also provides opportunities to create additional models with other uses, building models or forest inventory application can for example be extracted from the data. If the purpose is that the finished grid model is adequate, there is no direct reason to spend time creating a new model. But for a user with knowledge of laser data structure and processing, creating elevation models from raw LIDAR data could give advantages.
|
12 |
Karaktärisering av spatial upplösning i röntgenmikroskopiJabar, Alia January 2021 (has links)
X-ray imaging was a very important detection that is used in many useful functionalities as in healthcare. It would be powerful and facilitate several functions if we could come up with a method that gives a better resolution when doing X-ray imaging. This will be done by using two different detectors, a commercial detector (Innocare) and a direct converting detector (Medipix3). These two detectors have different properties. In addition to these detectors, a radiation source that radiates with X-rays has been used and a line mask that provides the ability to read the resolution of the image. The use of these detectors will provide answers to the investigation of limitations that its detectors have. / Röntgenavbildning är en viktig upptäckt som används i bland annat vården. Det skulle underlätta flera användningsområden om en metod kunde tas fram som ger bättre upplösning på bilder vid avbildning. I detta arbete undersöks vad som kan bidra till att få den bästa upplösningen vid röntgenavbildning. I undersökningen kommer det att användas två olika detektorer, en kommersiell detektor (Innocare) och en direktkonverterande detektor (Medipix3). Dessa två detektorer har olika egenskaper. Utöver dessa detektorer har en strålkälla som strålar med röntgenstrålar använts och en linjemask som ger möjligheten att läsa av bildens upplösning. Användningen av dessa detektorer kommer att ge svar på utredningen av begränsningar som dess detektorer har.
|
13 |
Den öppna tomhetenRönnegård, Sofia January 2021 (has links)
Som ung skådespelare var jag märkligt orustad inför mötet med de oundvikliga tomma mellanrum av ovisshet som väntade mig mellan uppdrag i mitt yrkesliv som frilansande skådespelare. Vem är jag när jag inte står på scenen? Som skådespelare behöver jag andra för att utöva mitt yrke, så när jag är ensam – vad är jag då? Hur handskas man med den här sidan av yrket och väl i arbete – hur handskas jag med den ovisshet och osäkerhet som är en förutsättning för konsten och kanske också för livet? Genom att sätta ord på en praktisk erfarenhet av att arbeta som frilansande skådespelare och på det konkreta sceniska arbetet och genom att spegla denna erfarenhet i filosofisk litteratur lyfter jag den osäkra tomheten som möjlighet – kanske till och med som nödvändighet. En öppen tomhet.
|
14 |
High resolution x-ray imaging by measuring the induced charge distribution / Högupplöst röntgenavbildning genom mätning av den inducerade laddningsfördelningenJin, Zihui January 2022 (has links)
Computed tomography (CT) is a medical imaging technique used to create cross-section images of human bodies based on x-rays. The emerging photon-counting CT detector shows several advantages compared with the traditional energy integrating detector. This thesis is based on the new generation deep silicon photon-counting CT detector developed by KTH Medical Imaging group, with a 12×500μm^2 pixel size. A method is proposed to achieve high spatial resolution with low computation resource consumption.A Monte Carlo simulation has been done to simulate the photon interaction along with the charge transport process in the detector. The charge cloud distribution and induced current are used to make a precise estimation of the interaction position in the direction along the collecting electrodes. The feasibility of such a method under estimated electronic noise and other detector geometries has been checked. By having a high spatial resolution of around 1μm in one direction, it could be beneficial in phase contrast imaging.Besides the small pixel geometry, simulations on current photon-counting detector geometry, similar to what is used in clinics, have also been carried out, with a study of the charge carrier transport behavior and charge sharing possibility. The result shows that although the charge sharing event could be used to help estimate interaction position, its low proportion among total events leads to little resolution improvement. Another study on the induced current as a function of time has been presented. By reducing the electrode width while keeping the same pixel width, the induced current signal peak appears to be sharper. / Datortomografi (CT) är en medicinsk bildteknik som används för att skapa tvärsnittsbilder av människokroppen med hjälp av röntgenstrålar. Den nya CT-detektorn med fotonräkning har flera fördelar jämfört med den traditionella energiintegrerande detektorn. Den här avhandlingen bygger på den nya generationen av den djupa kiseldetektorn för CT-detektorn med fotonträkning i kisel som utvecklats av KTH:s grupp för medicinsk avbildning, med en pixelstorlek på 12×500μm^2. En metod föreslås för att uppnå hög spatial upplösning med begränsad kapacitet för beräkningar.En Monte Carlo-simulering har gjorts för att simulera fotoninteraktionen tillsammans med laddningstransportprocessen i detektorn. Laddningsmolnets fördelning och den inducerade strömmen används för att göra en exakt uppskattning av interaktionspositionen i riktningen längs de uppsamlande elektroderna. Genomförbarheten av en sådan metod med beräknat elektroniskt brus och andra detektorgeometrier har kontrollerats. Genom att ha en hög rumslig upplösning på cirka 1 μm i en riktning kan detta vara fördelaktigt vid faskontrastbildtagning.Förutom den lilla pixelgeometrin har simuleringar av den nuvarande geometrin för detektorer som räknar fotoner, liknande den som används på kliniker, också utförts, med en studie av transportbeteendet för laddningsbärare och möjligheten till laddningsdelning. Resultatet visar att även om laddningsdelningshändelsen kan användas för att hjälpa till att uppskatta interaktionspositionen, leder dess låga andel av de totala händelserna till en liten förbättring av upplösningen. En annan studie av den inducerade strömmen som en funktion av tiden har presenterats. Genom att minska elektrodbredden samtidigt som man behåller samma pixelbredd verkar den inducerade signaltoppen bli skarpare.
|
15 |
Identifiering av laster i hushåll med andra generationens elmätareSpook, Albin, Söderlind, Tim January 2023 (has links)
With new smart power meters being installed in the households of Sweden an opportunity has presented itself. It allows the distribution companies to collect a variety of different measurements such as voltage in each phase and the total reactive and active power flowing to and from the customers. This thesis is written in collaboration with Öresundskraft AB, a distribution company in Helsingborg, Sweden. They wished to examine how the smart meter they install, the Kaifa MA304, could aid them in creating a power grid fit for the future. The thesis aims to achieve this goal by researching if PEV, plug-in electrical vehicles, can be identified utilizing data from the new power meters. It is also considered if district heating, and different types of electrical heating, can be identified using outside temperature measurements together with the data. Data has been collected and analyzed from 20 customers over a timespan of eight months in 2022. Here, the mean voltage for every ten minutes (in each phase) and active/reactive power accumulated during the last fifteen minutes is used. The raw data is transformed using a tool developed by the authors in python and is thereafter analyzed using the library pandas. Initial results showed a clear correlation between voltage drop and active power import during three phase charging. In the future, we will study the underlying mechanism of this correlation for devising algorithms to develop and use it as a reliable and effective means to identify PEV’s charging. Households with district heating had, as expected, a relatively even use of power consumption regardless of season or temperature. Electrically heated households used significantly more active power during lower temperature and cold months. The amount of imported reactive power greatly varies between customers, likely due to different technologies such as direct electrical heating and heating pumps. Future work should include knowledge of the utilized heating technologies to devise a method to identify these.
|
16 |
Utvärdering av en billig ultraljudsmaskin med avseende på bildkvalitet och temperaturökning / Evaluation of a Cheap Ultrasound Machine with Respect to Image Quality and Temperature IncreaseDragunova, Yulia, Anderberg, Joakim January 2021 (has links)
Ultraljudsdiagnostik baseras på propagering av mekaniska vågor och används för att avbilda tvärsnitt av kroppen i realtid. Prestandan, med avseende på kontrast, upplösning och måttmätningar, av CONTEC CMS600B-3, en relativ billig maskin är av intresse. Hur volymen av en fantom, dess ytarea och frekvens på utskickade vågor påverkar uppvärmningen av vävnader är även av intresse. Det undersöktes med ultraljudsmaskinerna CONTEC CMS600B-3 och Philips Lumify för att få resultat som inte beror på endast en maskin. Axiella upplösningen på CONTEC CMS600B-3 uppmättes med hjälp av ett gem till 0,61 mm och den laterala upplösningen till 1,27 mm med hjälp av ett snitt i cement. Maskinens måttmätningar hade en relativ avvikelse beroende på mätning. Resultat för reflektionskoefficienten visade att ultraljudsmaskinen har en funktion som kompenserar för attenuering och förstärker signaler med låga amplituder. Temperaturmätningarna undersöktes genom att skapa fantomer som efterliknar mänskliga vävnader med olika volymer och ytareor. En undersökning med ultraljudsmaskinerna visade att mer temperaturökning sker då ytarean ökas när volymen hålls konstant. Med avseende på säkerhet i temperaturökning, axiell upplösning och area/omkrets mått uppfyller CONTEC CMS600B-3 inte standarden och kan därmed inte användas inom sjukvården. / Diagnostics with ultrasound are based on propagation of mechanical waves and is used for imaging cross-section of the body in real-time. Performance, regarding contrast, resolution, and size measure, of CONTEC CMS600B-3, a relatively cheap machine is of interest. How volume of a phantom, its surface area, and frequency of the waves affects the heating of the tissues is also of interest. It was measured using ultrasound machines CONTEC CMS600B-3 and Philips Lumify to obtain results independent of the machine used. The axial resolution of CONTEC CMS600B-3 was established with a paperclip to be 0.61 mm and the lateral resolution was measured to be 1.27 mm using concrete with a triangular slit. Measurements of the machine had a relative deviation was depending on the measure. Results of the reflection coefficient indicated that CONTEC CMS600B-3 has a built-in function that compensates for loss of intensity due to attenuation and amplifies signals with lower amplitude to produce a B-mode image that the user can understand. Temperature measurements were done on phantoms that mimic the human body with different volumes and surface areas. An investigation with ultrasound machines showed an increase in temperature with increased surface area as the volume is held constant. When looking at safety with temperature rise, axial resolution and area/circumference measurements, CONTEC CMS600B-3 does not meet the standard and therefore cannot be used in healthcare.
|
17 |
Landtflicka icke, bondflicka alls icke – men icke heller rigtigt af bättre klass : Social stratifiering i ståndssamhällets fallCarlsson, Carl Mikael January 2011 (has links)
No description available.
|
18 |
Screen:play : Hamlet genom okända skärmdumpar / Screen:play : Hamlet throughout unknown screen capturesBjurström, Andrea January 2020 (has links)
For my graduation project I was interested in title cards, intertitles and captions from past films and clips. I am fascinated by their typography and art, but also the visual aspects of age and use. Aided by the writings of the artist and filmmaker Hito Steyerl, I explored the world of the poor quality image, an image that has been copied and pasted into different (mainly digital) channels of distribution. I found my own way of translating the visual language of an image with a past. Quoting one of the most retold (copied and pasted) plays; The Tragedy of Hamlet, Prince of Denmark written by William Shakespeare, ca 1600.
|
19 |
Improved Spatial Resolution in Segmented Silicon Strip Detectors / Förbättrad spatiell upplösning i segmenterade kiselstrippdetektorerBergström, Eva, Johansson, Ida January 2019 (has links)
Semiconductor detectors are attracting interest for use in photon-counting spectral computed tomography. In order to obtain a high spatial resolution, it is of interest to find the photon interaction position. In this work we investigate if machine learning can be used to obtain a sub-pixel spatial resolution in a photon-counting silicon strip detector with pixels of 10 µm. Simulated charge distributions from events in one, three, and seven positions in each of three pixels were investigated using the MATLAB® Classification Learner application to determine the correct interaction position. Different machine learning models were trained and tested in order to maximize performance. With pulses originating from one and seven positions within each pixel, the model was able to find the originating pixel with an accuracy of 100% and 88.9% respectively. Further, the correct position within a pixel was found with an accuracy of 54.0% and 29.4% using three and seven positions per pixel respectively. These results show the possibility of improving the spatial resolution with machine learning. / Halvledardetektorer är av stigande intresse inom forskning för användning i fotonräknande datortomografi med spektral upplösning. För att erhålla en hög spatiell upplösning är det av intresse att hitta fotonens ursprungliga interaktionsposition. I detta arbete undersöks om maskininlärning kan användas för att erhålla en spatiell upplösning på subpixelnivå i en fotonräknande kiselstrippdetektor med 10 µm pixlar. Laddningsfördelningen från simulerade interaktioner i en, tre, och sju positioner inom var och en av tre pixlar undersöktes med hjälp av applikationen Classification Learner i MATLAB® för att bestämma den korrekta interaktionspositionen. Olika maskininlärningsmodeller tränades och testades för att maximera prestandan. När pulser från en och sju positioner inom pixeln användes, kunde modellen hitta den korrekta pixeln med en noggrannhet på 100% respektive 88.9%. Vidare kunde den korrekta positionen inom en pixel bestämmas med en noggrannhet på 54.0% och 29.4% när tre respektive sju positioner inom varje pixel användes. Resultaten visar att det skulle vara möjligt att förbättra den spatiella upplösningen med hjälp av maskininlärning.
|
20 |
Wet Spinning of Lignin and Cellulose Precursor Fibers Using Cold Sodium Hydroxide Dissolution / Våtspinning av lignin- och cellulosaprekursorfibrer med kall natriumhydroxidupplösningVoytyuk, Nazariy January 2022 (has links)
Användningen av cellulosa och lignin för prekursorfibrer (PF) för kolfibrer (CF) är ett mycket intressant forskningsområde på grund av den stora miljöpåverkan som dagens PF-fossilbaserade råvara PAN har. Denna avhandling fokuserar på att utveckla PF med ett kallt NaOH-upplösningssystem med cellulosakoncentrationer från 4,5 till 5,5 viktprocent med varierande massaviskositet och tillsats av lignin från 0-40 viktprocent jämfört med cellulosa. Koagulationssystemet som användes var ett fosforbaserat system med fosforsyra och ammoniumdivätefosfat (ADP) och tvätttiden ändrades för att undersöka påverkan på det slutliga oorganiska innehållet i PF. Effekten av tillsatt lignin och användning av en högre massaviskositet med en förändrad cellulosakoncentration undersöktes. Det som noterades av resultatet av dragegenskaperna och spinnbarheten hos dopen visar en viss trend som är att hög massaviskositet på 330 ml/g och hög ligninhalt på 40 viktprocent (i jämförelse med cellulosamängden i dopen) tycks uppvisa dålig spinnbarhet och svagare dragegenskaper. Användning av längre tvätttider under centrifugeringsprocessen resulterade i en lägre ask- och fosforhalt i PF. / The use of cellulose and lignin for precursor fibers (PFs) for carbon fibers (CFs) is a highly researched topic because of the large environmental impact that today’s PF raw material PAN which is fossil based. This thesis focuses of developing PFs with a cold NaOH dissolution system with cellulose concentrations ranging from 4.5 to 5.5 wt% with varying pulp viscosity and the addition of lignin ranging from 0-40 wt% in comparison to the cellulose. The coagulation system used was a phosphorus-based system with phosphoric acid and ammonium dihydrogen phosphate (ADP) and the washing time was altered to investigate the impact on the final inorganic content in the PF. The impact of the addition of lignin and using a higher pulp viscosity with an altered cellulose concentration is researched. What was noticed from the result of the tensile properties and the spinnability of the dope shows a certain trend which is that high pulp viscosity of 330 ml/g and a high lignin content of 40 wt% (in comparison to the cellulose amount in the dope) seems to present poor spinnability and weaker tensile properties. Using longer washing times during the spinning process resulted in a lower ash and phosphorus content in the PF.
|
Page generated in 0.0666 seconds