• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 125
  • 1
  • Tagged with
  • 126
  • 126
  • 84
  • 55
  • 53
  • 52
  • 50
  • 44
  • 38
  • 38
  • 34
  • 33
  • 32
  • 31
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Efeito da ventilação não invasiva com pressão positiva contínua nas vias aéreas de pacientes oncológicos / Effects of noninvasive ventilation with continuous positive pressure on the airways of oncologic patients

Manfrim, Gabriela Marcon 26 September 2008 (has links)
INTRODUÇÃO: A insuficiência respiratória acomete grande parte dos pacientes oncológicos levando a altos índices de mortalidade. A ventilação não invasiva (VNI) pode auxiliar seu manejo, mas seus efeitos ainda são pouco conhecidos sobre os mecanismos de defesa pulmonar. OBJETIVOS: Observar o efeito da VNI com máscara facial usando-se geradores de fluxo com pressão positiva contínua (CPAP) e ventilador microprocessado no modo pressão de suporte + pressão positiva ao final da expiração (PSV + PEEP), a fim de verificar impacto nas propriedades viscoelásticas do muco respiratório e o conforto proporcionado ao paciente. MÉTODOS: A VNI foi instalada após diagnóstico de insuficiência respiratória em dezenove pacientes, admitidos nas unidades de tratamento intensivo do Hospital A. C. Camargo, sendo nove submetidos ao CPAP e dez com PSV + PEEP. Foram colhidos antes e após uma hora de VNI: os dados clínicos, secreção nasal, gasometria, e o grau de conforto através de uma escala visual. As propriedades físicas do muco (transportabilidade in vitro, adesividade e wettabilidade ou hidrofobicidade) foram avaliadas respectivamente no palato de rã, máquina da tosse e ângulo de contato. RESULTADOS: Os grupos eram homogêneos entre si em relação à idade, sexo, tipo e estadiamento do tumor e SAPS II. Em relação às propriedades físicas do muco, houve um aumento da transportabilidade in vitro do muco nasal com o sistema PSV + PEEP (p = 0,04) e um aumento na wettabilidade no grupo CPAP (p = 0,06). Os dois sistemas foram eficazes em melhorar significativamente os sinais vitais, a PaO2/FiO2, o padrão e o conforto respiratório e em evitar a intubação traqueal nas primeiras 24 horas (p < 0,05). Entretanto, independentemente do tipo de sistema de VNI usado, foram encontrados altos índices de intubação endotraqueal e mortalidade no seguimento destes pacientes. CONCLUSÃO: As propriedades físicas do muco (transportabilidade in vitro e wettabilidade) se alteraram após uma hora de uso da VNI e parecem ser dependentes da temperatura e umidificação dentro da máscara. A VNI mostrou-se útil em reverter a insuficiência respiratória em pacientes selecionados, ou pelo menos em trazer conforto para pacientes hipoxêmicos que a princípio recusam a intubação endotraqueal / INTRODUCTION: Respiratory failure is a common situation among cancer patients leading to high rates of mortality. Noninvasive ventilation (NIV) can help its management, but its effects are still unknown regarding the pulmonary defense mechanisms. OBJECTIVES: Observe the effect of NIV with facial mask using a flow generator with continuous positive pressure (CPAP) and standard intensive care unit ventilator using pressure support ventilation + positive end expiratory pressure (PSV + PEEP), to verify impact on the physical properties of respiratory mucus and the comfort provided to the patient. METHODS: NIV was started after diagnosis of respiratory failure in nineteen patients, admitted in the intensive care unit of the A. C. Camargo Hospital. Nine patients were submitted to CPAP and ten to PSV + PEEP. Nasal mucus, blood gases, and the degree of comfort through a visual scale were accessed before and after one hour. The physical properties of nasal mucus (transportabilility in vitro, adhesivity and wettability or hydrofobicity) were evaluated respectively by frog palate, cough machine and contact angle. RESULTS: Groups had similar characteristics about age, sex, tumor and SAPS II score. Regarding the physical properties of the mucus, there was an increase in mucus transportability (by the frog palate model) with the system PSV + PEEP (p = 0.04) and an increase in the contact angle in the CPAP groupo (p = 0.06). The two systems were effective in improving the vital signs, the PaO2/FiO2, the respiratory pattern and comfort and avoiding endotracheal intubation in the first 24 hours (p < 0.05). However, regardless of the type of NIV system used, high rates of endotracheal intubation and mortality were found. CONCLUSION: The physical properties of the mucus (transportability in vitro and wettability) changed after an hour of use of the NIV as a result of temperature and humidification into the mask. NIV was useful in reversing the respiratory failure in selected patients, or at least in bringing comfort for those who refuse endotracheal intubation
72

Ventilação mecânica não-invasiva em crianças com insuficiência respiratória aguda: uma revisão sistemática da literatura / Non invasive ventilation for children with acute respiratory failure: a systematic rewiew

Gonzaga, Carolina Silva 12 December 2007 (has links)
INTRODUÇÃO: A ventilação não-invasiva consiste na aplicação de pressão positiva na via aérea do paciente através de máscaras e interfaces sem a utilização de uma cânula intratraqueal. A presença da cânula na traquéia e outros fatores relacionados à ventilação invasiva convencional são responsáveis por diversas complicações. O uso da ventilação não-invasiva e o desenvolvimento de estudos sobre o tema têm aumentado nos últimos anos, com o objetivo de prevenir ou amenizar as complicações da ventilação invasiva. Em grupos selecionados de pacientes adultos, a ventilação nãoinvasiva é responsável pela diminuição da necessidade de intubação, mortalidade e custos hospitalares. Em pediatria, o número de estudos ainda é reduzido. OBJETIVOS: 1) Descrever os aspectos gerais relacionados ao uso da ventilação não-invasiva (interfaces, ventiladores, modos, pressões, tempo de uso e cuidados) em crianças e adolescentes com insuficiência respiratória aguda. 2) Avaliar a eficácia e a efetividade do uso da ventilação não-invasiva em crianças e adolescentes com insuficiência respiratória aguda. 3) Descrever as complicações da ventilação não-invasiva em crianças e adolescentes com insuficiência respiratória aguda. METODOLOGIA: Foi realizada uma revisão sistemática da literatura nas seguintes bases de dados: Medline, Lilacs, Embase e Colaboração Cochrane, no período de 1966 a maio de 2006, utilizando os seguintes termos: ventilação não-invasiva, CPAP, BIPAP, falha respiratória aguda, hipoxemia e hipercapnia. Os desfechos analisados incluíam: necessidade de intubação, mortalidade, efeitos sobre a oxigenação e ventilação. RESULTADOS: Das 120 publicações encontradas, 11 foram incluídas nesta revisão, sendo um ensaio clínico randomizado, uma revisão sistemática e nove séries de casos, envolvendo um total de 145 pacientes. A ventilação não-invasiva acarretou melhora clínica, e gasométrica dos pacientes. Apenas quatro, dos cento e quarenta e cinco pacientes, morreram. A maioria dos estudos, porém, não tinha grupo controle, o que impossibilitou uma análise da relação causal entre a ventilação não-invasiva em estudo e os efeitos encontrados. CONCLUSÕES: Devido ao reduzido número de ensaios clínicos randomizados, os dados mais atuais sugerem que a ventilação não-invasiva é ainda uma terapia experimental para crianças com IRtA / INTRODUCTION: The non invasive ventilation consists of the application of positive pressure in the airway of the patient through masks and interfaces without the use of a traqueal cannula. The presence of the cannula in the trachea and other factors related to the conventional invasive ventilation is responsible for diverse complications. The use of the non invasive ventilation and the development of studies on the subject have increased in the last years, with the objective to prevent and to brighten up the complications of the invasive ventilation. In selected groups of adult patients use of non invasive ventilation provides effective respiratory support while avoiding the need for endotracheal intubation and mortality decrease. OBJECTIVES: 1) Describe the general aspects related to the use of the non invasive ventilation (interfaces, fans, ways, pressures, time of use and cares) in children and adolescents with acute respiratory insufficience. 2) Avaliar the efficacy and the effectiveness of the use of the non invasive ventilation in children and adolescents with acute respiratory insufficience. 3) Describe the complications of the non invasive ventilation in children and adolescents with acute respiratory insufficience. METHODOLOGY: The medology consisted of a systematic review of literature on non invasive ventilation. The research was performed using: Medline, Lilacs, Embase and Cochrane Collaboration in the period of 1966 to the May of 2006, using the following terms: non invasive ventilation, CPAP, BIPAP, acute respiratory failure, hipoxemia and hipercapnia. The outcomes evaluted were: necessity of endotracheal intubation, mortality, effect on the oxygenation and ventilation. RESULTS: Of the 120 publications founded, 11 were to analyse the eficacy of the non invasive ventilation in the treatment of acute respiratory failure in pediatric patients. Of the 11 clinical trials, one was systematic review, one was randomized clinical trial and six were case series, involving a total of 145 patients. A decrease in respiratory rate, heart rate and an improvment in oxigenation and ventilation were related in all patients. Only four patients (4/145) died. However, the majority of the studies did not have control group what it disabled an analysis of the causal relation enters the non invasive ventilation in study and the outcomes evaluated. CONCLUSIONS:Because the reduced number of randomizaded clinical trials, the current data suggest that the non invasive ventilation is still an experimental therapy for children with acute respiratory failure
73

Efeitos do inibidor específico para serinoprotease rBmTI-A em modelo experimental de inflamação pulmonar alérgica crônica em camundongos Balb/c / Effects of the specific inhibitor for serine protease rBmTI-A in an experimental model of chronic allergic pulmonary inflammation in Balb/c mice

Florencio, Ariana Corrêa 05 April 2018 (has links)
INTRODUÇÃO: A asma ainda acomete um número crescente de indivíduos, podendo ser muito grave e, algumas vezes, fatal. A despeito da melhor eficiência diagnóstica e eficácia terapêutica, a maioria dos asmáticos graves não obtém controle total dos sintomas com as terapias disponíveis. Alguns estudos sugerem a atuação de inibidores de serinoproteases em diversos processos inflamatórios, entre estes inibidores encontra-se o Boophilus microplus trypsin Inhibitor (BmTI-A). OBJETIVO: Avaliar se o recombinante do inibidor de serinoproteases rBmTI-A modula a hiperresponsividade brônquica à metacolina, inflamação e remodelamento das vias aéreas em um modelo experimental de inflamação pulmonar alérgica crônica. MÉTODOS: Camundongos Balb-c foram divididos em 4 grupos: SAL (salina), OVA (sensibilizados com ovoalbumina), SAL+rBmTI-A (controle tratados com rBmTI-A ) e OVA+rBmTI-A (sensibilizados com ovoalbumina e tratados com rBmTI-A). Nos dias 0 e 14 do protocolo, os animais receberam injeção intraperitoneal (i.p) de salina (0,9% NaCl) (SAL e SAL+rBmTI-A) e ovoalbumina (50 ug/mL) (OVA e OVA+rBmTI-A). Nos dias 22, 24, 26 e 28 foram submetidos à inalação com salina (0,9% NaCl) ou ovoalbumina (10 mg/ml) e foram tratados com rBmTI-A (35,54 pmol em 50 uL de NaCl) ou apenas salina, via instilação nasal, nos dias 22 e 28. No dia 29, foram realizadas as seguintes análises: hiper-responsividade à metacolina e respostas máximas de resistência e elastância do sistema respiratório; quantificação do número total de células, macrófagos, linfócitos e polimorfonucleares no fluido do lavado broncoalveolar (FLBA); determinação da concentração das citocinas IL-4, IL-5, IL-10, IL-13, IL-17A e IFN-y no FLBA por citometria de fluxo (Cytometric Bead Array - CBA); avaliação da expressão de IL-4, IL-5, IL-10, IL-13, IL-17, MMP-9 e TIMP-1 nas vias aéreas; análise histopatológica do pulmão para quantificação de eosinófilos, fibras colágenas e elásticas e avaliação da atividade proteolítica de tripsina-like, MMP-1 e MMP9. A significância foi considerada p < 0,05. RESULTADOS: O tratamento com rBmTI-A nos animais sensibilizados reduziu a atividade proteolítica de tripsina no tecido pulmonar; a resposta máxima de Rrs e Ers; o número de polimorfonucleares e a concentração de IL-5, IL-10, IL-13 e IL-17A no FLBA; a expressão de IL-5, IL-13, IL-17, MMP-9 e TIMP-1 nas vias aéreas; o número de eosinófilos e a fração de fibras colágenas e elásticas nas vias aéreas do grupo OVA+rBmTI-A comparado ao grupo OVA (p < 0,05). CONCLUSÃO: O rBmTI-A atenuou a hiper-responsividade brônquica, a inflamação e o remodelamento nesse modelo experimental de inflamação pulmonar alérgica crônica. Embora mais estudos precisem ser realizados, este inibidor pode contribuir como potencial ferramenta terapêutica para o tratamento de asma / INTRODUCTION: Asthma still affects an increasing number of individuals and can be very serious and sometimes fatal. Despite the improved diagnostic efficiency and therapeutic efficacy, most severe asthmatics do not have complete symptom control with available therapies. Some studies suggest the role of serine protease inhibitors in various inflammatory processes, such as Boophilus microplus trypsin inhibitor (BmTIA). AIMS: To evaluate whether rBmTI-A serine protease inhibitor recombinant modulates bronchial hyperresponsiveness to methacholine, airway inflammation and remodeling in an experimental model of chronic allergic lung inflammation. METHODS: Balb/c mice were divided in four groups: SAL (saline), OVA (sensitized with ovalbumin), SAL+rBmTI-A (control treated with rBmTI-A) and OVA+rBmTI-A (sensitized with ovalbumin and treated with rBmTI-A). On days 0 and 14 of the protocol the animals received intraperitoneal injection (i.p) of saline (0.9% NaCl) (SAL and SAL+rBmTI-A) and ovalbumin (50 ug/mL) (OVA and OVA+rBmTI-A). On days 22, 24, 26 and 28 the groups were submitted to inhalations with saline (0.9% NaCl) or ovalbumin (10 mg/ml) and were treated with a rBmTI-A (35.54 pmol in 50 uL of saline or just saline) by nasal instillation, on the days 22 and 28. On day 29, the following analysis were performed: hyperresponsiveness to methacholine and the maximal resistance and elastance responses of the respiratory system were obtained; quantification of the total number of cells, macrophages, lymphocytes and polymorphonuclear in bronchoalveolar lavage fluid (FLBA); determination of the cytokines IL-4, IL-5, IL-10, IL-13, IL-17A and IFN-y concentration in FLBA by Cytometric Bead Array (CBA); IL4, IL-5, IL-10, IL-13, IL-17, MMP-9 and TIMP-1 expression in the airways; histopathological analysis of the lung for quantification of eosinophils, collagen and elastic fibers and evaluation of trypsin-like, MMP-1 and MMP9 proteolytic activity. Significance was considered when p < 0.05. RESULTS: The treatment with rBmTI-A in sensitized animals reduced: the proteolytic activity of trypsinlike in lung tissue, the maximum response of Rrs and Ers, the number of polymorphonuclear cells and the concentration of IL-5, IL-10, IL-13 and IL-17A in FLBA, the expression of IL-5, IL-13, IL-17, MMP-9 and TIMP-1 in the airways, the number of eosinophils and the fraction of collagen and elastic fibers in the airways of the OVA + rBmTI-A group compared to the OVA group (p < 0.05). CONCLUSION: rBmTI-A attenuated bronchial hyperresponsiveness, inflammation and remodeling in this experimental model of chronic allergic pulmonary inflammation. Although more studies need to be performed, this inhibitor may contribute as a potential therapeutic tool for the asthma treatment
74

Participação dos canais de potássio no efeito relaxante do ácido ent-7a-hidroxitraquiloban-18-oico em traqueia isolada de cobaia / Participation of potassium channels in the ent-7a-hidroxitrachyloban-18-oic acid relaxation effect on guinea pig trachea

Martins, Italo Rossi Roseno 17 February 2012 (has links)
Made available in DSpace on 2015-05-14T12:59:35Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 1945153 bytes, checksum: 2c1abc7e6111c3fc75af32ff4400e496 (MD5) Previous issue date: 2012-02-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / From Xylopia langsdorfiana A. St-Hil. & Tul. stem bark was isolated the diterpene of trachylobane class, ent-7α-hydroxytrachyloban-18-oic acid (trachylobane-318) that in previous studies showed to be able to relax guinea-pig trachea pre-contracted by carbachol (CCh). Thus, we aimed to investigate the action mechanism underlying in this trachylobane-318 relaxant activity. Trachea rings were suspended in organ baths, containing Kreb s solution, at 37 ºC and aired with carbogenic mixture. Isometric contractions were registered using a digital acquisition system. In order to evaluate a direct effect of the diterpene in Ca2+-calmodulin complex was used chlorpromazine (CPZ) (10-6 M), a calmodulin inhibitor, and we observed that trachylobane-318 relaxation effect (pD2 = 4.38 ± 0.07, n = 5) was not significantly altered in presence of this inhibitor (pD2 = 4.25 ± 0.07, n = 5). Then, was performed a protocol using different potassium (K+) extracellular concentrations which indicated that trachylobane-318 would be acting as a possible potassium channels activator since its relaxation was more potent when guinea-pig trachea was pre-contracted by KCl 18 mM (pD2 = 4.90 ± 0.25, n = 5) than by KCl 60 mM (pD2 = 3.88 ± 0.01, n = 5). To confirm the potassium channels participation was used a non-selective potassium channels blocker, tetraethylammonium (TEA+) 10 mM, that was pre-incubated before CCh addition, that resulted in an attenuation of diterpene relaxation (pD2 = 4.01 ± 0.06, n = 5). To determinate which potassium channels subtypes would be involved in the trachylobane-318 action, the diterpene relaxation curve was assessed in the presence of several potassium channels selective blockers. The fact of the trachylobane-318 relaxation curve was shifted to the right in a significant manner in the presence of 4-AP, a selective blocker of voltage activated K+ channels (Kv) (pD2 = 4.00 ± 0.06, n = 5); glibenclamide, a selective blocker of ATP-sensitive K+ channel (KATP) (pD2 = 3.91 ± 0.003, n = 5); apamin, a selective blocker of small conductance calcium-activated K+ channels (SKCa) (3.45 ± 0.14, n = 5) and big conductance calcium-activated K+ channels (BKCa) (3,80 ± 0,05, n = 5) is suggestive that the diterpene is modulating positively these channels to exert its relaxant effect. On the other hand, the inwardly rectifying K+ channels (Kir) was discarded since the relaxation curve was not altered (pD2 = 4.15 ± 0.10, n = 5) in the presence of BaCl2, selective blocker of these channels. Cyclic nucleotides participation was discarded since the relaxation curve obtained with aminophylline on guinea-pig contracted by CCh (pD2 = 4.27 ± 0.09, n = 5), a phosphodiesterases (PDEs) non-selective inhibitor, was not altered in trachylobane-318 presence (pD2 = 4.46 ± 0.08, n = 5). Thus, trachylobane-318 relaxant effect seems to involve the positive modulation of potassium channels subtypes Kv, KATP, SKCa and BKCa on guinea pig trachea. / A partir das cascas do caule de Xylopia langsdorfiana A. St-Hil. & Tul. foi isolado o diterpeno da classe dos traquilobanos, ent-7α-hidroxitraquiloban-18-oico (traquilobano-318) que em estudos anteriores mostrou-se capaz de relaxar a traqueia de cobaia pré-contraída com carbacol (CCh). Assim, o objetivo deste trabalho foi investigar o mecanismo de ação envolvido nesta atividade relaxante do traquilobano-318. Os anéis de traqueia foram suspensos em cubas para órgão isolado, contendo solução de Krebs, a 37º C e aerados com carbogênio. As contrações isométricas foram registradas com o auxílio de um sistema de aquisição digital. Para avaliar uma possível ação direta do diterpeno sobre o complexo Ca2+-calmodulina foi utilizado a clorpromazina (CPZ) (10-6 M), um inibidor da calmodulina, e observou-se que o efeito relaxante do traquilobano-318 (pD2 = 4,38 ± 0,07, n = 5) não foi significantemente alterado na presença deste inibidor (pD2 = 4,25 ± 0,07, n = 5). Em seguida foi realizado um protocolo usando diferentes concentrações extracelulares de potássio (K+) que indicaram que o traquilobano-318 estaria agindo como um possível ativador dos canais de K+, uma vez que seu efeito relaxante mostrou-se mais potente quando a traqueia era pré-contraída por 18 mM de KCl (pD2 = 4,90 ± 0,25, n = 5) do que quando pré-contraída por 60 mM de KCl (pD2 = 3,88 ± 0,01, n = 5). Para confirmar a participação dos canais de K+ utilizou-se um bloqueador não seletivo destes canais, tetraetilamônio (TEA+) (10 mM) que foi pré-incubado antes da adição de CCh, o que resultou na atenuação do relaxamento promovido pelo diterpeno (pD2 = 4,01 ± 0,06, n = 5). Com o objetivo de se determinar quais subtipos de canais de potássio estariam envolvidos na ação relaxante do traquilobano-318, a curva de relaxamento do diterpeno foi avaliada na presença de vários bloqueadores seletivos destes canais. O fato da curva de relaxamento do traquilobano-318 (pD2 = 4,38 ± 0,07) ter sido desviada para direita, de maneira significante, na presença de 4-AP, bloqueador dos canais de K+ sensíveis a voltagem (Kv) (pD2 = 3,91 ± 0,003); glibenclamida, bloqueador dos canais de K+ sensíveis ao ATP (KATP) (pD2 = 4,00 ± 0,06); apamina, bloqueador dos canais de K+ ativados pelo cálcio de pequena condutância (SKCa) (pD2 = 3,45 ± 0,14) e na presença de iberiotoxina, bloqueador dos canais de K+ ativados pelo cálcio de grande condutância (BKCa) (pD2 = 3,80 ± 0,05) sugere que o diterpeno está modulando positivamente estes canais para exercer seu efeito relaxante. Por outro lado a participação dos canais de potássio retificadores de entrada (Kir) foi descartada pois a curva de relaxamento do traquilobano-318 não foi alterada (pD2 = 4,15 ± 0,10, n = 5) na presença do BaCl2, bloqueador seletivos destes canais. A participação dos nucleotídios cíclicos foi descartada, uma vez que a curva de relaxamento em traqueia pré-contraída por CCh obtida com aminofilina (pD2 = 4,27 ± 0,09, n = 5), um inibidor não seletivo das fosfodiesterases (PDEs), não foi alterada na presença do traquilobano-318 (pD2 = 4,46 ± 0,08, n = 5). Assim, o efeito relaxante do traquilobano-318 parece envolver a modulação positiva dos subtipos de canais de potássio KATP, Kv, SKCa e BKCa em traqueia isolada de cobaia.
75

Abordagem por ressonância magnética do mecanismo de ação da pressão expiratória positiva nasal como forma de tratamento da apneia do sono

Braga, Carla Winei January 2012 (has links)
Esta tese de doutorado aborda o assunto apneia do sono, especialmente a síndrome de apneia e hipopneia obstrutiva do sono (SAHOS) como principal motivo de investigação. Nosso estudo teve como objetivo estudar o mecanismo fisiológico de funcionamento da válvula expiratória nasal (nEPAP) denominada Provent. Trata-se de um dispositivo descartável utilizado em ambas as narinas e que permite a inspiração normal, porém oferece resistência à expiração, fazendo com que o próprio paciente gere uma determinada pressão expiratória nasal. Este mecanismo de atuação da válvula determina algum grau de modificação na via aérea superior e no pulmão. Embora já se saiba que este dispositivo é efetivo no tratamento de pacientes com SAHOS leve e moderada3 o seu mecanismo fisiológico de funcionamento ainda não está completamente entendido. Utilizamos um método de ressonância magnética para avaliar a via aérea superior e o pulmão de pacientes em utilização do Provent nasal. Estudamos dez pacientes, 7 homens e 3 mulheres, entre 30 e 62 anos, com diagnóstico clínico de SAHOS e confirmado pela polissonografia (IAH>5 ev/h). Realizamos então, em diferentes momentos, polissonografia diagnóstica, polissonografia em uso da válvula nasal e exame de imagem (ressonância magnética). A faringe e o pulmão foram inspecionados e medidos durante alguns ciclos respiratórios, com e sem a válvula nasal. Neste estudo, validamos o exame de Ressonância Magnética para a avaliação da área transversal da via aérea superior e da capacidade residual funcional durante a respiração através da válvula nasal. Com os nossos resultados reforçamos os achados anteriores da literatura referentes aos três possíveis mecanismos de funcionamento desta válvula nasal: hiperinflação pulmonar importante aumentando a tração na traqueia, uma tendência à dilatação da faringe durante a expiração que se mantém no início da inspiração reduzindo a colapsabilidade da faringe e, finalmente, hipoventilação e aumento de PCO2. Considerando estes resultados, podemos dizer que a pressão expiratória positiva nasal pode ser uma alternativa de tratamento da SAHOS. Os resultados deste estudo são apresentados sob a forma de artigo já publicado em revista internacional de alto impacto científico (Journal of Applied Physiology). Adicionalmente, na forma de apêndice, realizamos outro estudo objetivando estudar o comportamento da SAHOS na Doença de Parkinson e as alterações ocasionadas em marcadores periféricos de lesão neuronal, especificamente a proteína S100B e a Enolase. Os transtornos do sono, incluindo os distúrbios respiratórios, são frequentes nos pacientes com Doença de Parkinson (DP), e, estudos já realizados mostram que a proteína S100B pode estar aumentada tanto em pacientes com SAHOS1 como naqueles com Doença de Parkinson2, sugerindo a possibilidade de algum grau de dano neuronal nestes pacientes quando comparados com indivíduos normais. Estes achados serviram de motivação para o estudo das variáveis neurofisiológicas do sono e do comportamento de biomarcadores em pacientes com Parkinson e, supostamente, SAHOS concomitantemente. / The issue of this doctoral thesis is Obstructive Sleep Apnea (OSA). Our study intended to clarify the mechanism of action of nEPAP (Nasal Expiratory Positive Airway Pressure), delivered with a disposable device (Provent, Ventus Medical). It has been shown to improve sleep disordered breathing (SDB) in some subjects3, but how it works is still not completely understood. We studied 10 patients, 7 males and 3 females, age between 30 and 62 years old, with clinic OSA and confirmed by sleep study (IHA>5). Sleep studies were performed in different nights, a night for diagnostic of OSA and other night under nasal valve. We did use MRI (Magnetic Resonance Imaging) to see upper airway and lung in patients wearing Provent. The present study demonstrate that significant hyperinflation (an increase in end expiratory lung volume) occurs during breathing through the device. In addition, there may be some trend to dilate the UA during expiration, and this may carry over into inspiration, providing a second mechanism to reduce the tendency of the UA to collapse in patients with SDB. Finally, we were able to show significant hypoventilation and a rise in PCO2 during breathing through the nEPAP during wakefulness, which may persist into sleep. Results are presented in the format of a paper published in a international journal with high scientific impact (Journal of Applied Physiology). In addition, as appendix, we did perform other protocol intended to study OSA in the Parkinson Disease (PD) and correlation with detectable levels of S100B and NSE, biochemical markers of neuronal damage. Sleep breathing disorders are frequent in Parkinson Disease and there are some studies showing that S100B, a known biochemical marker of astrocyte damage, is increased in both SAOS and PD1 2, suggesting a possible neuronal damage while compared to controls. These findings were motivation to investigate biochemical markers and sleep in patients with Parkinson. Our results suggest that sleep disturbance in PD causes a worse sleep quality and leads to S100B elevation during the night. Probably PD patients are suffering some degree of brain damage during the night that trigger a S100B response.
76

Efeito do uso da pressão positiva contínua nas vias aéreas sobre a qualidade de vida e sintomas depressivos em pacientes portadores da síndrome da apneia e hipopneia obstrutiva do sono

Birck, Marcio Adriano January 2011 (has links)
INTRODUÇÃO: A síndrome da apneia e hipopneia obstrutiva do sono (SAHOS) é uma doença crônica que se caracteriza por ronco e apneias que causam microdespertares e fragmentação do sono. O impacto da doença sobre o humor e a qualidade de vida não é bem conhecido. OBJETIVO: Avaliar o impacto do uso da pressão positiva contínua nas vias aéreas (CPAP) sobre sintomas depressivos e qualidade de vida em pacientes com SAHOS. MATERIAL E MÉTODOS: Pacientes com diagnóstico polissonográfico de SAHOS foram avaliados antes e seis meses após o tratamento com CPAP. Foram coletadas as seguintes medidas antropométricas: peso, altura, índice de massa corporal (IMC), circunferência do pescoço, medida da cintura e do quadril. A sonolência foi avaliada pela escala de sonolência diurna de Epworth, o sono pelo índice de qualidade do sono de Pittsburgh, a qualidade de vida através dos questionários SF-36 e FOSQ e os sintomas depressivos pelo inventário de depressão de Beck. RESULTADOS: Foram estudados 61 pacientes, sendo 42 homens e 19 mulheres, com índice de apneias e hipopneias (IAH) de 40,3 ± 27,2 eventos/hora. A média de idade foi de 53,2 ± 9,0 anos e do IMC 30,36 ± 3,93 kg/m², sendo que 96,7% dos pacientes apresentavam sobrepeso ou obesidade. Valores acima do normal para a circunferência do pescoço foram observados em 73,8% e da cintura em 72% dos indivíduos. Com o tratamento com CPAP observou-se redução da sonolência (13,2 ± 4,8 vs 7,9 ± 3,3 pontos; p=0,0001), melhora da qualidade do sono (escore 10,1 ± 4,5 vs 4,1 ± 2,5; bons dormidores pré 9 vs 36 pós; p<0, 01), melhora da qualidade de vida em todos os domínios do FS-36 (p<0,01) e do FOSQ (81,9 ± 19,5 vs 91,7 ± 14,4 pontos; p=0,00001). Os sintomas depressivos melhoraram após o uso do CPAP (12,0 ± 8,6 vs 7,5 ± 5,1; p<0,01), os quais estavam presentes em 33 pacientes antes do tratamento e em 19 após 6 meses de seguimento. Não houve associação entre sintomas depressivos e sonolência. Houve correlação fraca entre sintomas depressivos e IAH (r=0,28; p=0,02), e moderada a forte com todos os domínios do SF-36 (r entre -0,58 e - 0,72; p=0,0001). CONCLUSÕES: Nosso estudo demonstra que a terapia com CPAP tem impacto positivo sobre a sonolência, qualidade do sono e melhora a qualidade de vida e os sintomas depressivos dos portadores de SAHOS. Os sintomas depressivos não se relacionaram com a sonolência e com a gravidade da doença, mas se associaram com a qualidade de vida. / INTRODUCTION: Obstructive sleep apnea syndrome (OSAS) is a chronic disease characterized by snoring and apneas that cause microarrousals and sleep fragmentation. The effects of the disease on mood and health related quality of life is not well known. OBJECTIVE: To evaluate the impact of the use of continuous positive airway pressure (CPAP) on depressive symptoms and quality of life in patients with OSAS. MATERIAL AND METHODS: Patients with OSAS diagnosed by polyssomnography underwent evaluation before and after 6 months treatment with CPAP. Weight, height, body mass index (BMI), neck, waist and hip circumference were measured. Daytime sleepiness was evaluated using the Epworth scale, sleep quality using the Pittsburgh sleep quality index and quality of life using SF-36 and FOSQ. Depressive symptoms were detected through the Beck Depression Inventory. Data were analized by Student T test, McNemar test and Pearson correlation test. RESULTS: We studied 61 patients with OSAS, 42 males and 19 females, with apnea hypopnea index (AHI) of 40.3 ± 27.2 events/hour. The mean age was 53.2 ± 9.0 years, BMI was 30.4 ± 3.9 kg/m², and 90.7% of the patients were overweight or obese. Abnormal neck and waist circumference were observed in 73.8% and 72% of patients, respectively. After treatment with CPAP there was a decrease in daytime sleepiness (13.2 ± 4.8 vs 7.9 ± 3.3 points; p=0.0001), an increase in sleep quality (10.1 ± 4.5 vs 4.1 ± 2.5; the number of good sleepers 9 before vs 36 after CPAP; p<0.01), and in quality of life as shown by SF-36 (p<0.01) and FOSQ (81.9 ± 19.5 vs 91.7 ± 14.4 points; p=0.00001). Depressive symptoms improved after use of CPAP (12.0 ± 8.6 vs 7.5 ± 5.1; p<0,01), they were reported by 33 patients before treatment and by 19 after six months of follow up. There was a weak correlation between depressive symptoms and AHI (r=0.28; p=0.02) and no association between depressive symptoms and daytime sleepiness. The correlation among depressive symptoms and SF-36 domains varied from r=-0.58 and r=-0.72 (p=0.0001). CONCLUSIONS: Our study demonstrates that the CPAP therapy has a positive impact on daytime sleepiness and sleep quality and improves quality of life and depressive symptoms in patients with OSAS. Depressive symptoms were not related to daytime sleepiness or disease severity, but were associated with quality of life.
77

Abordagem por ressonância magnética do mecanismo de ação da pressão expiratória positiva nasal como forma de tratamento da apneia do sono

Braga, Carla Winei January 2012 (has links)
Esta tese de doutorado aborda o assunto apneia do sono, especialmente a síndrome de apneia e hipopneia obstrutiva do sono (SAHOS) como principal motivo de investigação. Nosso estudo teve como objetivo estudar o mecanismo fisiológico de funcionamento da válvula expiratória nasal (nEPAP) denominada Provent. Trata-se de um dispositivo descartável utilizado em ambas as narinas e que permite a inspiração normal, porém oferece resistência à expiração, fazendo com que o próprio paciente gere uma determinada pressão expiratória nasal. Este mecanismo de atuação da válvula determina algum grau de modificação na via aérea superior e no pulmão. Embora já se saiba que este dispositivo é efetivo no tratamento de pacientes com SAHOS leve e moderada3 o seu mecanismo fisiológico de funcionamento ainda não está completamente entendido. Utilizamos um método de ressonância magnética para avaliar a via aérea superior e o pulmão de pacientes em utilização do Provent nasal. Estudamos dez pacientes, 7 homens e 3 mulheres, entre 30 e 62 anos, com diagnóstico clínico de SAHOS e confirmado pela polissonografia (IAH>5 ev/h). Realizamos então, em diferentes momentos, polissonografia diagnóstica, polissonografia em uso da válvula nasal e exame de imagem (ressonância magnética). A faringe e o pulmão foram inspecionados e medidos durante alguns ciclos respiratórios, com e sem a válvula nasal. Neste estudo, validamos o exame de Ressonância Magnética para a avaliação da área transversal da via aérea superior e da capacidade residual funcional durante a respiração através da válvula nasal. Com os nossos resultados reforçamos os achados anteriores da literatura referentes aos três possíveis mecanismos de funcionamento desta válvula nasal: hiperinflação pulmonar importante aumentando a tração na traqueia, uma tendência à dilatação da faringe durante a expiração que se mantém no início da inspiração reduzindo a colapsabilidade da faringe e, finalmente, hipoventilação e aumento de PCO2. Considerando estes resultados, podemos dizer que a pressão expiratória positiva nasal pode ser uma alternativa de tratamento da SAHOS. Os resultados deste estudo são apresentados sob a forma de artigo já publicado em revista internacional de alto impacto científico (Journal of Applied Physiology). Adicionalmente, na forma de apêndice, realizamos outro estudo objetivando estudar o comportamento da SAHOS na Doença de Parkinson e as alterações ocasionadas em marcadores periféricos de lesão neuronal, especificamente a proteína S100B e a Enolase. Os transtornos do sono, incluindo os distúrbios respiratórios, são frequentes nos pacientes com Doença de Parkinson (DP), e, estudos já realizados mostram que a proteína S100B pode estar aumentada tanto em pacientes com SAHOS1 como naqueles com Doença de Parkinson2, sugerindo a possibilidade de algum grau de dano neuronal nestes pacientes quando comparados com indivíduos normais. Estes achados serviram de motivação para o estudo das variáveis neurofisiológicas do sono e do comportamento de biomarcadores em pacientes com Parkinson e, supostamente, SAHOS concomitantemente. / The issue of this doctoral thesis is Obstructive Sleep Apnea (OSA). Our study intended to clarify the mechanism of action of nEPAP (Nasal Expiratory Positive Airway Pressure), delivered with a disposable device (Provent, Ventus Medical). It has been shown to improve sleep disordered breathing (SDB) in some subjects3, but how it works is still not completely understood. We studied 10 patients, 7 males and 3 females, age between 30 and 62 years old, with clinic OSA and confirmed by sleep study (IHA>5). Sleep studies were performed in different nights, a night for diagnostic of OSA and other night under nasal valve. We did use MRI (Magnetic Resonance Imaging) to see upper airway and lung in patients wearing Provent. The present study demonstrate that significant hyperinflation (an increase in end expiratory lung volume) occurs during breathing through the device. In addition, there may be some trend to dilate the UA during expiration, and this may carry over into inspiration, providing a second mechanism to reduce the tendency of the UA to collapse in patients with SDB. Finally, we were able to show significant hypoventilation and a rise in PCO2 during breathing through the nEPAP during wakefulness, which may persist into sleep. Results are presented in the format of a paper published in a international journal with high scientific impact (Journal of Applied Physiology). In addition, as appendix, we did perform other protocol intended to study OSA in the Parkinson Disease (PD) and correlation with detectable levels of S100B and NSE, biochemical markers of neuronal damage. Sleep breathing disorders are frequent in Parkinson Disease and there are some studies showing that S100B, a known biochemical marker of astrocyte damage, is increased in both SAOS and PD1 2, suggesting a possible neuronal damage while compared to controls. These findings were motivation to investigate biochemical markers and sleep in patients with Parkinson. Our results suggest that sleep disturbance in PD causes a worse sleep quality and leads to S100B elevation during the night. Probably PD patients are suffering some degree of brain damage during the night that trigger a S100B response.
78

A influência das alterações nasais na adesão ao aparelho de pressão aérea positiva em pacientes com síndrome da apneia obstrutiva do sono / The influence of nasal alterations in adherence to the continuous positive airway pressure in obstructive sleep apnea patients

Haddad, Fernanda Louise Martinho [UNIFESP] 26 January 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:49:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-01-26 / Introdução: Trabalhos vêm mostrando uma maior ocorrência de alterações nasais em pacientes com Síndrome da Apneia Obstrutiva do Sono (SAOS) quando comparados a controles, porém a correlação existente entre a permeabilidade nasal e a adesão ao aparelho de pressão aérea positiva (CPAP) é assunto ainda controverso na literatura. Além disso, não existe um consenso sobre qual ou quais seriam os melhores métodos de avaliação da função nasal. Desse modo, o objetivo deste trabalho é avaliar a influência das alterações nasais na adesão ao CPAP, em pacientes com SAOS. Método: Foram incluídos pacientes de ambos os gêneros, entre 25 a 65 anos, com diagnóstico de SAOS moderada a grave. O protocolo constituiu de questionários, rinoscopia anterior, nasofibrolaringoscopia flexível, “peak flow ” nasal inspiratório, rinometria acústica e polissonografia para titulação pressórica do CPAP. Os pacientes receberam o CPAP para uso domiciliar por 6 meses e foram acompanhados em um programa educacional. Ao término de 6 meses, os pacientes que utilizaram o CPAP 4 horas ou mais por noite, em pelo menos 70% das noites, foram considerados como tendo boa adesão; os demais como tendo má adesão. Resultados: De 45 pacientes incluídos, 34 finalizaram o estudo. Onze (33,4%) pacientes eram do sexo feminino e 23 (67,6%) do sexo masculino, com idade média de 53,1 ± 9,1 anos. Dezesseis (47,1%) pacientes apresentaram boa adesão. Os parâmetros clínicos significantes foram: índice de massa corpórea (IMC), circunferência cervical (CC) e índice de apneia e hipopneia (IAH) maiores (p=0,030, p=0,006, p=0,032); e a saturação mínima da oxihemoglobina menor (p=0,041) no grupo de boa adesão. Os parâmetros nasais não apresentaram diferenças entre os grupos. As correlações com o maior número de horas de uso do CPAP foram: maior IMC (p=0,043), maior CC (p=0,007), maior IAH (p=0,043), maior pressão do CPAP (p=0,012), menor média das áreas nasais na posição supina (p=0,029). No modelo de regressão linear, os achados relacionados ao maior número de horas de uso do CPAP foram: maior CC (p=0,015), maior IAH (p=0,034), menor nota do quadro de sintomas nasais (p=0,007) e menor volume das fossas nasais na posição supina (p=0,001). Conclusões: A maior parte dos parâmetros nasais avaliados foram contraditórios ou não influenciaram a adesão ao CPAP. Os parâmetros que se correlacionaram à adesão ao CPAP neste grupo de pacientes com SAOS foram os preditores clínicos e polissonográficos da presença e gravidade da SAOS. / Introduction: Researches showed a higher incidence of nasal disorders in patients with Obstructive Sleep Apnea Syndrome (OSAS) compared to controls, but the correlation between the nasal permeability and positive airway pressure device (CPAP) compliance is controversy in the literature. Furthermore there is no consensus on what would or would be the best methods of assessment of nasal function. Thus, the aim of this study was to evaluate the contribution of nasal alterations in CPAP compliance in patients with OSAS. Method: We included patients of both genders, between 25 to 65 years, with moderate to severe OSAS. The protocol consisted of questionnaires, rhinoscopy, nasofibroscopy, nasal inspiratory peak flow, acoustic rhinometry and polysomnography. The patients received CPAP for home use for 6 months and were followed in an educational program. At the end of 6 months, patients who used CPAP 4 hours or more per night, at least 70% of nights were considered as having good compliance, and the others as having poor compliance.Results: Of 45 patients enrolled, 34 finished the study. Eleven (33.4%) patients were female and 23 (67.6%) males, mean age 53.1 ± 9.1 years. Sixteen (47.1%) patients had good compliance (use &#1048725; 4 hours per night). Clinical parameters were significant: body mass index (BMI), neck circumference (NC) and apnea-hypopnea index (AHI) higher (p = 0.030, p = 0.006, p = 0.032), and oxyhemoglobin saturation minimum minor (p = 0.041) in the group with good compliance. Nasal parameters showed no differences between groups. The correlations with the largest number of hours of CPAP use were: higher BMI (p = 0.043), higher NC (P = 0.007), higher AHI (p = 0.043), higher CPAP pressure (p = 0.012), lower average of minimal sectional areas in the supine position (p = 0.029). In the linear regression model, the findings related to the greater number of hours of CPAP use were: higher CC (p = 0.015), higher AHI (p = 0.034), lower notes of nasal symptoms (p = 0.007) and lower volume of nasal cavity in the supine position (p = 0.001). Conclusions: Most nasal parameters evaluated were contradictory or did not influence adherence to CPAP. The parameters that were significantly correlated with adherence to CPAP in this group of OSA patients were clinical and polysomnographic predictors of the presence and severity of OSA. / TEDE / BV UNIFESP: Teses e dissertações
79

Efeitos da aplicação da EPAP sobre a tolerância ao esforço em indivíduos portadores de insuficiência cardíaca / Effects of application of EPAP on exercise tolerance in individuals with heart failure

Thofehrn, Claudia 02 March 2012 (has links)
Made available in DSpace on 2016-12-06T17:06:54Z (GMT). No. of bitstreams: 1 Claudia Thofehrn.pdf: 804135 bytes, checksum: 1c917a778904272b382a9452df5cb3e7 (MD5) Previous issue date: 2012-03-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Patients with heart failure (HF) are often limited by dyspnea and fatigue, often aggravated by pulmonary congestion present in this syndrome. Efficacy of Positive Expiratory Pressure Airway (EPAP) has been tested in diverse populations, as in the postoperative period of CABG surgery, stable chronic obstructive pulmonary disease and obstructive sleep apnea, providing effects such as variation in intraocular pressure alveolar, increased functional residual capacity, redistribution of extravascular fluid and decreased intrapulmonary shunt. In an attempt to reduce dyspnea and respiratory work in patients with HF using the EPAP is a therapeutic alternative in view of its beneficial effects and considering the changes in lung function are related to pulmonary edema. The aim of this study was to evaluate the effects of the use of EPAP on exercise tolerance in patients with HF, functional class II and III (NYHA). For the sample, we selected 28 patients with LVEF <40%, which conducted three tests of 6-minute walk (6MWT): learning with and without use of EPAP use of it. To generate a positive expiratory pressure, adapted to the mask expiratory resistor by a spring loaded set to offer a pressure of 8 cmH2O. The comparison between the data obtained was performed by paired t test or Wilcoxon test, depending on the normality of the data. As a result, it was found that the use of EPAP increased without significant minute volume and the perception of effort was increased after 6MWT that the associated use of positive pressure. With regard to oxygen saturation, the use of EPAP in 6MWT increased significantly the same, despite the finding baseline saturations were within normal parameters before testing. It was concluded that the use of EPAP did not increase exercise tolerance in patients with HF in the 6MWT, but there is a need for additional studies to test different levels of the same long-term training and / or analyze patients with degrees of clinic more pronounced. / Pacientes portadores de Insuficiência Cardíaca (IC) frequentemente são limitados pela dispnéia e fadiga, muitas vezes agravadas pela congestão pulmonar presentes nesta síndrome. A eficácia da Pressão Positiva Expiratória nas Vias Aéreas (EPAP) já foi testada em diversas populações, como em pós-operatório de cirurgia de revascularização miocárdica, doença pulmonar obstrutiva crônica estável e apneia obstrutiva do sono, proporcionando efeitos como a variação na pressão intra-alveolar, aumento da capacidade residual funcional, redistribuição do líquido extravascular e diminuição do shunt intrapulmonar. Na tentativa de reduzir a dispnéia e o trabalho ventilatório em portadores de IC o uso da EPAP é uma alternativa terapêutica, tendo em vista seus efeitos benéficos e considerando que as alterações na função pulmonar estão relacionadas à edema pulmonar. O objetivo desta pesquisa foi avaliar os efeitos da utilização da EPAP sobre a tolerância ao esforço em indivíduos portadores de IC, classe funcional II e III (NYHA). Para a amostra, foram selecionados 28 pacientes com FEVE < 40%, os quais realizaram três testes de caminhada de 6 minutos (TC6 ): aprendizado, com uso da EPAP e sem uso da mesma. Para gerar a pressão positiva expiratória, adaptou-se à uma máscara um resistor expiratório por carga de mola ajustado para oferecer uma pressão de 8 cmH2O. A comparação entre os dados obtidos foi realizada por meio de teste t pareado ou teste de Wilcoxon, conforme a normalidade dos dados. Como resultado, verificou-se que o uso da EPAP aumentou sem significância o volume minuto, porém a percepção de esforço foi maior após o TC6 que associou o uso da pressão positiva. Com relação à saturação de oxigênio, o uso da EPAP no TC6 elevou a mesma significativamente, apesar das saturações basais encontrarem-se dentro de parâmetros normais antes da realização do teste. Concluiu-se que o uso da EPAP não promoveu aumento na tolerância ao esforço em indivíduos portadores de IC no TC6 , porém, há a necessidade de estudos adicionais que testem níveis diferentes da mesma no treinamento a longo prazo e/ou analisem pacientes com graus de descompensação clínica mais acentuada.
80

Histamina induz inflamação das vias aéreas e produção de muco em pulmão de camundongos / Histamine induces airway inflammation and mucus production in lung tissue of mice

Vieira, Letícia Vilma dos Santos [UNESP] 07 August 2017 (has links)
Submitted by LETICIA VILMA DOS SANTOS VIEIRA null (leticiavieir@hotmail.com) on 2017-09-22T15:22:13Z No. of bitstreams: 1 DISSERTAÇÃO_Letícia Vilma dos Santos Vieira.pdf: 2517417 bytes, checksum: 934c0060d04d2bb79afa7cb1c1f7b10a (MD5) / Approved for entry into archive by Monique Sasaki (sayumi_sasaki@hotmail.com) on 2017-09-27T18:54:34Z (GMT) No. of bitstreams: 1 vieira_lvs_me_araca.pdf: 2517417 bytes, checksum: 934c0060d04d2bb79afa7cb1c1f7b10a (MD5) / Made available in DSpace on 2017-09-27T18:54:34Z (GMT). No. of bitstreams: 1 vieira_lvs_me_araca.pdf: 2517417 bytes, checksum: 934c0060d04d2bb79afa7cb1c1f7b10a (MD5) Previous issue date: 2017-08-07 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Na inflamação alérgica, a histamina desencadeia papel crucial na indução de sintomas, tais como vasodilatação, broncoconstrição e produção de muco. O objetivo deste estudo foi investigar os efeitos da histamina na inflamação e no remodelamento das vias aéreas, avaliando para tanto a produção de muco e colágeno em modelo murino de inflamação pulmonar. Camundongos Balb/c machos de 20-25g foram estimulados, por via intratraqueal, com histamina em diferentes concentrações (10, 50 e 100 µM) e avaliados após 6, 24 e 48 horas. A partir dos dados resultantes do ensaio dose-resposta, foi realizado tratamento farmacológico, onde animais foram separados em 5 grupos (6 camundongos por grupo): Grupo 1 (PBS), controle não estimulado; Grupo 2 (Histamina), controle estimulado; Grupo 3 (Histamina + Loratadina); Grupo 4 (Histamina + Dexametasona) e Grupo 5 (Histamina + Dexametasona e Loratadina). Analisamos a migração de leucócitos no lavado broncoalveolar (LBA) e no tecido pulmonar. As alterações estruturais no tecido pulmonar e na traqueia foram avaliadas por análise histopatológica, bem como a produção de muco e deposição de colágeno usando Alcian blue/Periodic Acid Shiff e Tricômio de Masson, respectivamente. O sobrenadante do LBA e o tecido pulmonar foram coletados para quantificar os níveis SCF e CCL3 por ELISA de captura. A expressão gênica de Muc5ac, Gob-5, Col1a2 e receptores de histamina foi avaliada por RT-PCR em tempo real. Nossos resultados demonstram que a histamina induz inflamação das vias aéreas, com presença de infiltrado leucocitário no LBA e no tecido pulmonar. Além disso, os animais estimulados com histamina demonstraram aumento significativo na expressão gênica de Muc5ac, Gob-5 e Col1a2 no tecido pulmonar, produção SCF e CCL3 no LBA e pulmão, bem como apresentaram alterações estruturais na traqueia e no tecido pulmonar, tais como infiltrado leucocitário, presença de células caliciformes, produção de muco e depósito de colágeno. O pré-tratamento com dexametasona (DEX) inibiu a migração leucocitária no LBA e tecido pulmonar, e também diminuiu a expressão gênica de Muc5ac no tecido pulmonar, diminuiu a produção de SCF e CCL3 no LBA e pulmão, bem como reduziu a produção de muco e a deposição de colágeno no pulmão. Já o pré-tratamento com loratadina (LOR), bloqueador de H1, inibiu parcialmente a migração celular no LBA, mas não no tecido pulmonar, enquanto que a associação farmacológica entre DEX e LOR diminuiu significativamente a migração leucocitária tanto no LBA como no tecido pulmonar. Com base nos dados acima, sugere-se que a histamina induz inflamação das vias aéreas, promovendo a migração de leucócitos possivelmente através da produção de SCF e CCL3, bem como provoca alterações estruturais na traqueia e no tecido pulmonar, tais como produção de muco, deposição de colágeno, e esses efeitos tem a participação dos receptores H1 e H4. / In allergic inflammation, histamine exerts a crucial role in the induction of symptoms, such as vasodilation, bronchoconstriction and mucus production. The aim of this study was to investigate the effects of histamine in inflammation and airway remodeling, evaluating the mucus production and collagen in a murine model of pulmonary inflammation. Male Balb/c mice of 20-25g were challenged by intratracheal instillation of histamine at different concentrations (10, 50 and 100 μM) and evaluated after 6, 24 and 48 hours. From the data resulting from the dose-response assay, pharmacological treatment was performed, and animals were separated into 5 groups (6 mice per group): Group 1 (PBS), non-challenged control; Group 2 (Histamine), challenged control; Group 3 (Histamine + Loratadine); Group 4 (Histamine + Dexamethasone) and Group 5 (Histamine + Dexamethasone and Loratadine). We analyzed the recruitment of leukocytes in bronchoalveolar lavage (BAL) and lung tissue. Structural changes in lung tissue and trachea were assessed by histopathological analysis, as well as mucus production and collagen deposition using Alcian blue/Periodic Acid Shiff and Masson's Trichrome, respectively. BAL supernatant and lung tissue were collected for SCF and CCL3 levels quantification by capture ELISA. The gene expression of Muc5ac, Gob-5, Col1a2, and histamine receptors was evaluated by RT-PCR real time. Our results demonstrated that histamine induces airway inflammation, with presence of leukocyte infiltrate in BAL and lung tissue. In addition, histamine-challenged animals demonstrated a significant increase in the gene expression of Muc5ac, Gob-5 and Col1a2 in lung tissue, SCF and CCL3 production in BAL and lung, as well as structural changes in the trachea and lung tissue, such as leukocyte infiltrate, presence of goblet cell, mucus production and collagen deposition around the airways. Dexamethasone pre-treatment (DEX) inhibited leukocyte recruitment in BAL and lung tissue, decreased gene expression of Muc5ac in lung tissue, decreases SCF and CCL3 production in BAL and lung, as well as mucus production and collagen deposition in the lung. Already pre-treatment with loratadine (LOR), an H1 blocker, partially inhibited cell migration in BAL, but not in lung tissue, whereas the pharmacological association between DEX and LOR significantly reduced leukocyte recruitment in both the BAL and the lung tissue. Putting the above data together, we suggest that histamine induces airway inflammation, promoting the recruitment of leukocytes possibly through the production of SCF and CCL3, as well as causes structural changes in the trachea and lung tissue, such as mucus production, collagen deposition, and these effects might be mediated by H1 and H4 receptors.

Page generated in 0.0555 seconds