• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 1
  • Tagged with
  • 35
  • 15
  • 15
  • 13
  • 11
  • 8
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Energianalys på Volvo Aero

Månsson, Markus, Wahlgren, Peter January 2008 (has links)
<p>Detta examensarbete har genomförts på Volvo Aero i Trollhättan och består av tre delar: en kartläggning av processventilationens uppbyggnad på ett antal utvalda maskiner och beräkning av dess energiåtgång, en jämförelse ur energieffektivitetssynpunkt mellan ett nyutvecklat maskinkoncept som kallas MultiTask-Cell och traditionell tillverkning, sist har en tomgångsanalys gjorts i verkstaden för att identifiera vad som använder elenergi då ingen produktion sker.</p><p>För att kunna genomföra uppgifterna har mätningar av elanvändningen gjorts på både maskinnivå och transformatorer, detta för att kunna beräkna energianvändning på utvalda maskiner och även få en helhetssyn över verkstadens energianvändning. Det har även gjorts datainsamling och intervjuer för att få grepp över processventilationens funktion och uppbyggnad.</p><p>Det finns två varianter på processluften, ett där konstant relativt högt luftflöde används och ett när man genom varvtalsreglering av fläkten använder ett lägre grundflöde som forceras en viss tid vid spindelstopp. Ur energisynpunkt är metoden med grundflöde och forcering att föredra då det leder till både mindre energiförluster genom processluften och en stor minskning av fläktens elbehov. Det har även räknats ut en teoretisk energibesparing vid införande av värmeåtervinning för två maskingrupperingar.</p><p>Jämförelsen mellan MultiTask-cellen och traditionella maskiner har gjorts genom att mäta den energi det krävs för att tillverka en detalj för respektive tillverkningssätt. MultiTask-cellen visade sig använda cirka 25 % mindre energi än de traditionella maskinerna för tillverkning av samma typ av detalj.</p><p>Tomgångsanalysen visar på ett högt effektuttag även då det ej sker någon produktion på Volvo Aero. Detta beror till stor del på att maskinerna har en relativt hög tomgångsförbrukning. Denna krävs för att hålla maskinen varm vilket ger en så problemfri uppstart som möjligt. Att byta ut allmänbelysningens armatur till nyare och modernare skulle årligen ge en betydande energibesparing.</p>
22

HÅLLBART BYGGANDEMED HJÄLP AV BIM : Effektiva energianalyser och LCC / SUSTAINABLE BUILDING USING BIM : Efficient Energy Analyzes and LCC

Mika, Jonas, Fossland, Andreas January 2015 (has links)
The society strives for sustainable development, in the construction industry it is expressed through sustainable building. Energy and LCC analyzes increases the ability to make conscious decisions in the process. A problem in the construction industry is that energy and LCC analysis is not used to the desired extent, as they are perceived as complicated and time consuming. The report aims to achieve a more sustainable building through increased use of energy and LCC analyzes.The goal is to show how BIM can be used to improve the efficiency of the energy and LCC analyzes. The study was conducted with a literature review and a case study to answer which information that is required in a BIM model to perform energy and LCC analyzes. The study also shows which software can be used in BIM based energy and LCC analyzes and how the analyzes can be carried out efficiently. The result shows that effective analyzes may be performed if the BIM-model contains the relevant information for making analyzes. Information not necessary for the analysis complicates the procedure. There are a variety of software that manages energy and LCC analyzes differently. The Software’s are optimized for different BIM platforms and they use various file formats for the transfer of information. Effective analyzes are achieved by following a proven method or guide with few steps in the workflow. Through knowledge of the capability of the used file format, the right information can be added to the model at the right point in the process of analyzes without loss of information. To increase the use of energy and LCC analyzes, an integration of the analysis tools into the BIM platforms would be necessary. / Samhället strävar efter ett allt mer hållbart byggande som reducerar påfrestningarna på miljön. Energi- och LCC-analyser(LifeCycleCosting, eller Livscykelkostnad) ökar möjligheten att fatta medvetna beslut i processen. Ett problem inom byggbranschen är att energi- och LCC-analyser inte används i önskad utsträckning då de upplevs som komplicerade och tidskrävande. Syftet med rapporten är att få ett mer hållbart byggande genom en ökad användning avenergi- och LCC-analyser. Målet är att visa hur BIM kan användas för att effektivisera energi- och LCC-analyser. Studien har gjorts med en litteraturstudie och en fallstudie för att besvara vilkeninformation som krävs i en BIM-modell för att utföra energi- och LCC-analyser. Studien visar även vilka mjukvaror som kan användas vid BIM-baserade energi och LCC-analyser och hur analyserna kan utföras på ett effektivt sätt. Resultatet visar att effektiva analyser kan genomföras om BIM-modelleninnehåller relevant information för att göra analyser. Annan informationkomplicerar analysförfarandet. Det finns en stor mängd olika mjukvaror somhanterar energi- och LCC-analyser på olika sätt. Mjukvarorna som kan göra energianalyser är optimerade för olika BIM-plattformar och använder olika filformat för informationsöverföring. Genom kunskap om filformatens kapacitet, kan rätt information tillföras modellen vid rätt moment i analysprocessen utan att information går förlorad. För att göra effektiva analyser, är användandet av en beprövad metod eller guide önskvärt. En möjlighet för att öka användandet av energi- och LCC-analyser, skulle vara att en integration av analysverktygen in i BIM-plattformarna utvecklades.
23

Energianalys av fastighet Brynäs 12:1 : Energikartläggning med effektiviseringsåtgärder inriktning mot ventilation

Blomqvist, Sofia, Sundby, Dennis January 2014 (has links)
Energianvändningen i Sverige och världen förväntas öka och bostads- och servicesektorn står för 40 % av världens totala energibehov. Det är viktigt att energieffektivisera redan befintliga byggnader och optimera dess system då en lägre energianvändning gynnar både miljön och ekonomin. En byggnads ventilationssystem står för en stor del av en fastighets energianvändning och det finns ofta stor potential för systemet att optimeras och effektiviseras. En fastighetsägare vill inte ha fastigheter som står outhyrda. Outhyrda lokaler betyder minskade intäkter i hyror och i vissa fall tillkommer energianvändning för de tomma lokalerna i form av uppvärmning och ventilation som fastighetsägaren måste betala. System som helt kan stängas av eller styras beroende på ventilationsbehov behövs för att den sistnämnda kostnaden ska reduceras helt under tiden lokalen är outhyrd och för att den totala energianvändningen ska minska när en hyresgäst flyttar in. Ventilationens syfte är att ventilera bort fukt, värme, partiklar och koldioxid så att ett bra inomhusklimat skapas för de personer som vistas i byggnaden. Den vanligaste ventilationsprincipen för offentliga byggnader är att ventilera luft med ett konstant luftflöde genom ett constant air volume-system. Med behovsanpassad ventilation i form av ett variable air volume-system kan stora besparingar göras då man anpassar luftflödet efter det verkliga ventilationsbehovet istället för att ventilera byggnaden med ett konstant maxflöde. En installation av ett VAV-system i form av CO2- eller närvarostyrning sänker ventilationens energianvändning samtidigt som kvaliteten på inomhusmiljön bibehålls. Arbetet som har utförts innefattar en energikartläggning av fastigheten Brynäs 12:1 då en energikartläggning hjälper till att förstå en byggnads energianvändning och identifierar möjliga energisparåtgärder. Energianvändningen för fastighetens delsystem har kartlagts och analyserats för att ta fram förslag på besparingsåtgärder. Resultatet av energikartläggningen visade att det fanns stor besparingspotential för ventilationsaggregat TA1, TA2 och TA3:s el- och värmeanvändning. Om de åtgärder rörande ventilationen som presenteras i arbetet som till exempel flödes- och tidsreducering vidtas kan en energibesparing på 333 MWh/år uppnås, vilket är 28 % av fastighetens totala årliga energianvändning. / Energy use in Sweden and the world is expected to increase and the residential and services account for 40% of total world energy demand. It is important that the energy efficiency of existing buildings and optimizing its systems as a lower energy benefits both the environment and the economy. A building's ventilation system account for a large proportion of a property's energy use, and there is often great potential for the system to be optimized and streamlined. A property owner does not want properties that are vacant. Vacant premises mean less income in rent and in some cases there will be increased energy costs for the empty space in form of heating and ventilation, for the property owner to pay. Systems that can completely shut off or controlled depending on ventilation requirements needed for the latter cost will be reduced completely when the premises are vacant and that the total energy will decrease when a tenant moves out. Ventilating purpose is to divert moisture, heat, particulates and carbon dioxide so that a good indoor climate is created for the people staying in the building. The most common ventilation principle for public buildings is to vent air with a constant air flow through a CAV system. With demand-based ventilation in the form of a VAV system, huge savings can be made when one adjusts airflow to the actual ventilation requirement instead of ventilating the building with a constant maximum flow. An installation of a VAV system in the form of CO2 or presence control, reduces ventilation energy consumption, while the quality of the indoor environment is maintained. The work that has been carried out includes an energy survey of the property Brynäs 12:1 as an energy survey helps to understand a building's energy use, and identifies potential energy savings. The energy use for the building subsystems have been identified and analyzed in order to develop proposals for cost cutting measures. The results of the energy audit revealed that there was great potential for savings for ventilation units TA1, TA2 and TA3's electricity and heat use. If the measures for ventilation as presented in the work, such as flow and time reduction is taken, an energy saving of 333 MWh/year is achieved, which is 28% of the property's total annual energy consumption.
24

Uppvärmning med fjärrvärme och frånluftsvärmepump i småhus : En energi-, miljö- och kostnadsanalys för bostadsområdet Lindbacka i Gävle / Fulfill heat demand in houses with district heating and exhaust air heat pump

Karlberg, Madeleine January 2021 (has links)
In Gävle there exists a residential area called Lindbacka where some of the houses are supplied with heat from both district heating and exhaust air heat pump. Gävle Energi owns the district heating system in Gävle and are interested in evaluating the effects from a combined heating system. Based on that, the aim of this study has been to evaluate the impacts a combined system with both district heating and heat pump can have compared to if only one of the two is installed in a house. The thesis has studied these perspectives in an energy, environmental and economic analysis. The results from the energy analysis display that the heat losses in the district heating system relative to the amount of heat sold to customers are relatively large during the year, especially in the summer when the losses are larger than sold amount of energy. The results from the environmental analysis indicates that heat pumps have a larger climate impact during operation measured in tons of carbon dioxide equivalents compared to district heating. On the other hand, the economic analysis present heat pumps to be the cheapest heating option for a customer. The most expensive option for a customer is to install both an exhaust air heat pump and connect to the district heating system since this leads to double fixed and variable costs during the year. For Gävle Energi the economic analysis indicates that the investment cost of building the district heating system to Lindbacka was not profitable since the investment cost does not pay back in 30 years. Some of the houses in Lindbacka has been excluded in the thesis due to insufficient data. This will have an impact on the results in the thesis.
25

Energianalys av anrikningsverk G1A : Förbrukning och styrbarhet

Schönfeldt, Tyra January 2022 (has links)
Anrikningsverket G1A i Boliden analyseras för att undersöka dess möjligheter till en flexiblare elanvändning i syftet att minska effekttoppar och jämna ut last. Detta genom att kartlägga maskiner och utrustningar i olika processavsnitt i verket som använder energi i form av el för att utföra sin uppgift, med slutmålet att presentera vilka möjligheter det finns för att justera energiförbrukningen hos dessa.  Analysverktyget Seeq, vilket är en applikation skapad för processdataanalys, används för att analysera data och dialog med personalen på anrikningsverket för att samla ytterligare information om maskinerna och utrustningen i olika de processavsnitten. Resulterande möjligheter för en flexiblare energianvändning i anrikningsverket är att optimera värmesystemet för att undvika perioder då det både värms upp och kyls av samtidigt, sänka värmen i vissa lokaler tillfälligt för att balansera vid effekttoppar, stänga av eller sänka värmen till mindre områden under kortare tidsperioder eller anpassa värmen efter dygnsrytmen; t.ex. höja värmen under nätter när elen är billigare om man betalar timpris. Eventuellt stoppa tellurverket om bufferttanken där har tillräckligt låg nivå att den kan hantera att varmlakningstanken töms, villkorstyra ångpannan så den inte går då den totala effekten är hög, använda en buffert i sandpumpningen eller att takta in pumparna till dammarna så att de inte går samtidigt. Även att tillfälligt minska varvtalet på kvarnarna i malningen eller inrätta en jämnare reglering av infrakten kan vara möjliga åtgärder.
26

Utvärdering av svetsgardiner som luftflödesstyrande element inom datorhallar. / Evaluation of welding curtains as an airflow-guiding element within data centers

Barnö, Max, Bui, Linda January 2014 (has links)
Denna rapport har genomförts för att utvärdera om svetsgardiner som luftflödesstyrandeelement i datorhallar ger någon energieffektivisering. Vilket utslag systemet ger dåsvetsgardiner används jämförs med utslaget när inga svetsgardiner finns med och påverkarsystemet. Får servrarna tillräckligt mycket kalluft för att kylas och behöver man tre styckenrumskylare för att kyla rummet tillräckligt? Rapporten har också genomförts för att ge enutvärdering av svetsgardinernas form och funktion. Volvo Personvagnar vill veta om det ärekonomiskt hållbart att använda svetsgardiner i sina datorhallar.Det är också önskvärt att bevisa att det blir ett bättre klimat runt servrarna när svetsgardineranvänds. Resultatet visar att temperaturskillnaden, före och efter rumskylarna samt före ochefter servrarna, ökar för luften i pilotanläggningen. Det leder i sin tur till atttemperaturskillnaden på köldbäraren för kompressorkylmaskinen kommer att minska.Eftersom rumskylarnas funktion, vid specifika fall när svetsgardiner inte existerar, leder tillbegränsning av massflödet på köldbäraren kommer massflödet att vara större under längreperioder vid tilldragna svetsgardiner. Massflödet ökar ofta mer än vad temperaturskillnadenminskar vilket leder till att mer värme kyls bort från pilotanläggningen vid tilldragnasvetsgardiner. Alltså är inte systemet rätt kalibrerat för att utnyttja svetsgardinernas funktion.Vid stor belastning på beräkningsklustren är ofta begränsningen av massflödet förköldbäraren svag. Det leder till att flödena är ungefär lika stora vid både till- och fråndragnasvetsgardiner. Då får man en minskad driftkostnad. Det går inte att bevisa en minskaddriftkostnad genom minskat kompressionsarbete vid alla belastningar och under kortareperioder p.g.a. att rumskylarna inte är korrekt kalibrerade. Inte heller en nämnvärd ökning idriftkostnad inträffar hos kompressorerna. Det verkar som att svetsgardinernas utformninginte är optimalt då kalluften från rumskylarna blåser förbi runt kanterna på gardinerna ochdärmed kyler delar av den varma luften i det varma området. För att detta problem inte skalluppstå kan man t.ex. använda längre gardiner, fästa gardinerna högre upp, fästa gardinernaäven på sidorna och vid golvet. Slutligen bör man få ett bättre resultat av att inte användauppdelad svetsgardin. Kalluftflödet till servrarna är större än vad som behövs men intetillräckligt stort att man bör stänga av rumskylaren som står i det kalla området. Ökar manrumskylarnas reglervärde på temperaturen (för när rumskylana kommer begränsa massflödetpå köldbäraren genom sig) med förslagsvis någon till några grader Celsius, (djupare analyskrävs) vid användandet av svetsgardiner, kommer systemet kunna utnyttja svetsgardinernaspotential. En mindre driftkostnad i form av att mer värme kommer kunna kylas bort tillsamma arbeta för kompressorn kommer då troligtvis inträffa. / <p>This project has been conducted to evaluate if welding curtains function as an airflow-guiding</p><p>element within a data centers will increase the energy efficiency of the system. What result</p><p>does the system show when welding curtains are being used? Compared with what the system</p><p>show when no welding curtains are being used and doesn’t affect the system is something</p><p>that’s look into. Does the servers get enough cold air to sustain its usage? Do you need three</p><p>cooling systems to cool the room sufficiently? The report has also been conducted to provide</p><p>an evaluation of the welding curtains function as well as its design. Volvo Cars wants to know</p><p>if it’s economically viable to use welding curtains in their data centers. It’s also desirable to</p><p>prove that there is a better climate around the servers when welding curtains are being used.</p><p>The result shows that the temperature difference of the air, before and after the cooling</p><p>systems and before and after the servers, increases in the data center. This also leads to that</p><p>the temperature difference of the coolant for compressor chiller will decrease. Because of the</p><p>room coolers limiting of the mass flow (in certain situations) on the coolant to a lesser extent</p><p>when welding curtains are being used, the mass flow rate will be greater for longer periods.</p><p>The mass flow often increases more than the temperature difference decreases and that leads</p><p>to that more heat is cooled from the data center when welding curtains are being used. Thus,</p><p>the system isn’t properly calibrated to utilize welding curtains to a full extent. At large loads</p><p>on the computing clusters, the room coolers affect the mass flow of the coolant to a minimum.</p><p>The result is that the mass flow is approximately equal both with and without welding</p><p>curtains in use. This leads to an increase in efficiency of compressor chiller because more heat</p><p>is being chilled with the same work of the compressor as without any welding curtains. When</p><p>welding curtains are being used you can’t prove that a reduced operating cost will occur due</p><p>to reduction of the compressor work. This is because of the room coolers are not properly</p><p>calibrated. Neither a significant increase in operating cost occurs in the compressor chiller.</p><p>An indication occurs that the design of the welding curtain is not optimal because of that the</p><p>cold air from the cooler systems blows past the edges of the curtains and thus cools some of</p><p>the hot air in the heated area. To solve this problem one can e.g. use taller welding curtains,</p><p>replace the curtains to a higher position and attach the curtains on both sides as well as on the</p><p>floor. Also the use of a welding curtain that isn’t divided in two or more parts is an idea that</p><p>can be implemented. The cold airflow to the servers flows at a larger rate than necessary but</p><p>not that sufficient that one, in the cold area, should put the cooling system in idle mode. If you</p><p>increase the cooling systems temperature set-value (temperature set-value for when the cooler</p><p>limits the mass flow through it) by a few degrees Celsius when welding curtains are being</p><p>used (a deeper analysis is needed), the system will hopefully be able to utilize the potential of</p><p>the welding curtains. I.e. increased efficiency of the compressor chiller because more heat is</p><p>being chilled to the same work of the compressor.</p><p>Program: Energiingenjörsprogrammet med inriktning mot eldistribution</p>
27

Energikartläggning av ett 1970-tals lägenhetshus på Skarpövägen i Nacka kommun : Simulering av energibesparande åtgärder i ”IDA Indoor Climate and Energy” / Energy mapping of a apartment block from the 1970s on Skarpövägen, Nacka municipality

Melin, Tobias January 2014 (has links)
This study has been carried out in the spring of 2014 on behalf of PQR Consult AB in Stockholm. The aim of the study has been to analyse the energy usage of the building Skarpövägen 1 in order to explore the possibilites of saving energy by using appropriate equipment. These possible solutions have been simulated by using the programe IDA Indoor Climate and Energy, combined with a life cycle cost analysis. The laundry building, Skarövägen 23, has also been analysed due to its high amount of energy usage. The result of the energy analysis showed that the energy usage was much higher than the energy declaration. The energy usage of Skarpövägen 1 was 193 kWh/m2, which is 25 % higher than the energy declaration of 155 kWh/m2. Based on the energy saving actions, the most profitable investment would be to install heat recycling that would save 47470 kWh district heating per year with a pay-back time of 14 years. The results for the laundry building showed that there is a possibility to save up to 75% of the electricity usage by replacing certain equipment that is dependent on a high amount of energy. Throughout the whole analysis it has been clear that the energy usage in the buildings are higher than necessary. However, the energy saving actions have shown that there are ways to reduce the usage in the buildings. Some changes are simple to make while others would take longer, with varied pay-back time. In the long run those changes are vital for a sustainable reduction of energy usage. / På uppdrag av PQR Consult AB i Stockholm har detta examensarbete utförts under våren 2014. Syftet var att utföra en energikartläggning av byggnaden Skarpövägen 1 och simulera energibesparande åtgärder i programmet IDA Indoor Climate and Energy. Utöver detta har en livscykelkostnadsanalys gjorts för att underlätta ekonomiska jämförelser. Även tvättstugan, Skarpövägen 23, har delvis kartlagts eftersom den har en hög energianvändning med all elutrustning i byggnaden. Resultatet i energikartläggningen visade att energianvändningen var betydligt högre än energideklarationens värden. För Skarpövägen 1 var energianvändningen 193 kWh/m2 vilket är ca: 25 % högre än energideklarationens 155 kWh/m2. Efter att ha utvärderat de simulerade energibesparingsåtgärderna för Skarpövägen 1 så dras slutsatsen att den mest lönsamma investeringen skulle vara att installera ett värmeåtervinningssystem vilket skulle ge en besparing på 47470 kWh fjärrvärme per år och ha en återbetalningstid på 14 år. Resultatet för tvättstugan visade att 14880 kWh el årligen skulle sparas om torkskåpen byttes ut, vilket är en sänkning med ca: 75 % av elbehovet jämfört med befintliga torkskåp. De energibesparande åtgärderna har visat att utrymme finns för besparingar i byggnaderna vilket är ett viktigt steg på vägen att minska energianvändningen i bostadssektorn.
28

Utveckling av simuleringsverktyg: effekt- och energianalys för publika laddningsstationer / Development of simulation tool: power and energy analysis of public charging stations

Nabiallahi, Edwin, Broman, Markus January 2023 (has links)
Detta arbete har gjorts i samarbete med Mälarenergi AB i Västerås. Målet har varit att utveckla ett användarvänligt program för simulering av elbilsparkeringar i nutid och framtid. Data har samlats in och analyserats för flera nuvarande parkeringar i Västerås för att urskilja olika beteendemönster för olika typer av parkeringsplatser. Tillsammans med elbilsstatistik för Sverige har dessa data används som grund för simuleringsverktyget som skrivits i programmeringsspråket Python. För att kunna verifiera simuleringarnas kvalitet har även Monte Carlo-metoden använts. Det slutgiltiga verktyget kan simulera olika parkeringstyper med valfria indata för tre tidsscenarion, 2023, 2030 och 2045. Resultaten visar att verktyget till viss del överestimerar den mängd effekt som faktiskt behövs för parkeringarna och kan snarare användas som en grov uppskattning än en faktisk mall för hur användningen ser ut för en viss elbilsparkering i Västerås. Vidare analys av den verkliga datan visar att många av laddningsstationer uppnår lägre effektnivåer än vad de är dimensionerade för, vilket gör att utnyttjandet av smart laddning eller ett energilager inte skulle utnyttjas till fullo. För dessa fall finns det möjlighet att i dagsläget sänka den tillåtna maxeffekten av tekniska och ekonomiska skäl. Simuleringar för framtida scenarion visade att det kan vara relevant med nödvändigt med implementering av smart laddning för att inte överbelasta näten om det sker ett teknikskifte mot DC-laddning. / This project has been done in cooperation with Mälarenergi AB in Västerås. The goal has been to create software for simulating parking lots with EV-charging. By analyzing data collected from several types of parking lots in Västerås, behavioral patterns have been designed and used together with EV-statistics to create simulations. Code has been written in the programming language Python. To verify the integrity of these, a Monte Carlo method has been used and the results have been compared to the real-life powerdata from Västerås parking lots. Results show that the software simulates power patterns quite well but overestimates the actual power usage. Furthermore, forecasts for the growth of EVs in Sweden by Power Circle have been used as basis for future simulations, specifically years 2030 and 2045. Outcome of running the software shows that for all the current Västerås parking lots, the dimensions for the power consumptions, 63 A fuses, are much larger compared to actual power usage. Outcomes from the future simulations showed that smart charging of EVs as well as the use of energy storages could be necessary as the technology shifts more towards DC-charging. In conclusion, many of the current EV charging stations could be run at a lower max power threshold, which would lower company expenses but still make sure to provide enough power for consumers.
29

Energianalys av nybyggt trygghetsboende / Energy analysis of newly built house with the concept of safe living

Beckne, Petter, Palander, Eric January 2018 (has links)
Senast år 2045 ska utsläpp av växthusgaser reduceras till en nollnivå enligt Sveriges riksdag. I Sverige står bostads- och servicesektorn för 40 % av den sammanlagda energiförbrukningen. Studien baseras på en energianalys av ett flerbostadshus beläget i Ronneby, av typen trygghetsboende vilket leder till en unik boendesituation i byggnaden. Byggnaden förbrukar cirka 25 % mer energi än den beräknade samt avtalade energiförbrukningen. Syftet är att i framtida projekt kunna få energiberäkningar att stämma bättre överens med verklig specifik energiförbrukning. Studien bygger på energisimuleringar, termografering samt undersökningar av vädringsvanor. Simuleringarna som är baserade på den verkliga datan, visar en förväntad energiförbrukning i liknande storleksordning som den uppmätta förbrukningen. Skillnaden mellan resultaten i studiens olika beräkningar beror på den unika boendesituationen i byggnaden, indatan för installationer samt byggnadens klimatskal. Studien påvisar att aktuella boendesituationer i byggnader och hur byggnader nyttjas påverkar den specifika energiförbrukningen i stor grad. / After 2045, greenhouse gases should be reduced to a zero level according to the Swedish parliament. Energy use in Sweden from residential and service sector is 40 % of the country´s total energy use. The study is based on an energy analysis of a multi-family building in Ronneby. The building is a trygghetsboende, which means unique living conditions for the residens. Actual energy use in the building is about 25 % higher than projected energy use. The main purpose of the study is to make energy calculations to match better with real specific energy use. The study is based on energy simulations, thermography and interviews of residents´ airing habits. Results from the simulations based on actual data, show an expected energy use similar to the measured values. Differences between the simulations depend on the unique conditions in the building, input data for ventilation and the building envelope elements. The conclusion is that living habits of residents in buildings have a decisive role in the buildings energy use.
30

Energianalys av byggnad med installerat ångsystem för matlagningsprocesser : Kan ånga vara mer effektivt än el för matlagning?

Bodell, Erik, Åhlander, Simon January 2017 (has links)
Det finns ett stort behov av att minska energianvändningen i världen. Igenom att minska energibehovet så minskar den negativa miljöpåverkan. I en ständigt växande värld där det byggs i allt snabbare takt så ökar också energibehovet. Igenom att effektivisera befintliga byggnader kan energibehovet stagnera eller till och med minska trots utbyggnaden. Igenom att energieffektivisera så kan mer av den energi som används nyttjas istället för att den ska stå för onödiga förluster. Fortifikationsverket har en restaurangbyggnad de anser använder för mycket energi. Denna byggnad innehåller en restaurang som använder ett ångsystem för matproduktion, vilket gör byggnadens energisystem unikt. För att kunna minska byggnadens energianvändning kartläggs och analyseras den i denna rapport. Denna fallstudie genomförs med en litteraturstudie för att utveckla kunskaperna inom området. Sedan utförs mätningar i byggnaden som därefter analyseras och presenteras så att eventuella avvikelser och brister påpekas. Under arbetets gång upptäcktes att en säkring var felinstallerad för mätningen av elanvändningen till en av ångpannorna. Igenom att ha åtgärdat detta för att kunna fakturera rätt så spar Fortifikationsverket nästan 170 000 kr per år som den ångpannan går. Utöver detta så analyserades ångsystemet och uppskattningar gjordes för att kunna svara på om ånga är effektivare än el för matlagning. Det visar sig att ångsystemet kan vara effektivt om stor mängd mat tillagas. Med hänsyn till nätter, helger och de dagar då mindre mat tillagas så är el-utrustning effektivare eftersom att det helt stängs av när det inte används. Till skillnad från ångsystemet som måste täcka upp för förlusterna för att behålla temperatur och tryck, även när systemet inte används. Igenom att byta ut ångsystemet till motsvarande utrustning som drivs av el skulle det gå att spara 205 MWh/år, enligt uppskattningar. Ångsystemet står för 35% av byggnadens totala elanvändning och är den största posten för energianvändningen och är därför den del som fokuserats mest på. Utöver ångsystemet så analyserades övrig energianvändning för att kunna ge förslag på besparingar. Många av förslagen är grundade på vissa uppskattningar och antaganden vilket måste beaktas. Några konkreta exempel på besparingar som kan göras är att sänka inomhustemperaturen för att spara 50 MWh/år, installera tilläggsfönster för att spara upp till 140 MWh/år, installera effektivare kylaggregat – 200 MWh/år, installera bättre styrning till ventilationen – 110 MWh/år, installera bättre styrning till belysning – 40 MWh/år. / There is a great need to reduce energy use in the world. By reducing energy demand, this reduces the negative environmental impact. In a constantly growing world, where it is built at an ever faster pace, the energy demand also increases. By increasing energy efficiency inexisting buildings, energy requirements may stagnate or even decrease despite expansion. By increasing energy efficiency, more of the energy demand can be used instead of standing for energy losses. Fortifikationsverket has a building they believe use too much energy. This building contains a restaurant that uses a steam system to heat its food, which makes the building's energy system unique. In order to reduce the energy consumption of the building, an energy audit is completed and analyzed in this report. This case study is conducted with a literature study to develop the knowledge in the field. Then measurements in the building are performed which are subsequently analyzed and presented to indicate any deviations and deficiencies. During the work it was discovered that a fuse was incorrectly installed to measure the electricity consumption of one of the boilers. By correcting this in order to be able to bill correctly, Fortifikationsverket saves almost 170,000 SEK per year as the boiler goes. In addition to this, the steam system was analyzed and estimates were made to respond if steam is more effective than electricity for cooking. It turns out that the steam system can be effective if a large amount of food is cooked. Considering nights, weekends and days when less food is cooked, electrical equipment is more effective because it completely turns off when not in use. Unlike the steam system that has to cover the energy losses to keep temperature and pressure, even when the system is not in use. By replacing the steam system with equivalent electrical equipment, it couldsave 205 MWh/year, according to estimates.The steam system accounts for 35% of the building's total electricity demandand is the largest item for energy use and is therefore the most focused area. In addition to the steam system, other energy usage was analyzed to provide energy savings. Many of the proposals are based on certain estimates and assumptions which must be considered. Some examples of savings that can be made is lowering the indoor temperature to save 50 MWh/year, install additional windows to save up to 140 MWh/year, install more efficient cooling units -200 MWh/year, install better ventilation control systems-50 MWh/year, install better controls for indoor lighting -40 MWh/year.

Page generated in 0.1843 seconds