• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 264
  • 7
  • 4
  • 1
  • 1
  • Tagged with
  • 281
  • 188
  • 76
  • 70
  • 57
  • 44
  • 40
  • 39
  • 34
  • 34
  • 30
  • 26
  • 25
  • 25
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Avaliação da eficácia em curto prazo do uso de placas estabilizadoras oclusais de cobertura total e dispositivos NTI (nociceptive trigeminal inhibitory splint) no tratamento da dor miofascial da musculatura mastigatória / Short-term evaluation of efficacy of the use of stabilization occlusal splint and NTI (nociceptive trigeminal inhibitory splint) in the treatment of the myofascial pain from masticatory muscles

Alencar, Eloisa Nassar de 21 March 2011 (has links)
O objetivo dessa pesquisa foi testar a hipótese de que o tratamento através de aparelhos oclusais é benéfico na melhora dos sinais e sintomas da Dor Miofascial (DMF) de origem mastigatória quando comparado a um grupo controle. Para isso, 51 indivíduos foram avaliados segundo os critérios estabelecidos pelo Research Diagnostic Criteria for Temporomandibular Disorders (RDC/ TMD) para determinar a presença de Dor Miofascial. Essa amostra foi então dividida de maneira randomizada e estratificada em três grupos: 21 pacientes receberam tratamento com placa estabilizadora rígida com cobertura total e técnicas de aconselhamento e mudanças comportamentais para pacientes com DTM (Disfunção Temporomandibular), 16 receberam o dispositivo NTI e técnicas de aconselhamento e mudanças comportamentais para pacientes com DTM e 14 participaram como grupo controle, recebendo apenas técnicas de aconselhamento e mudanças comportamentais para pacientes com DTM. Os dispositivos foram instalados e utilizados em uso parcial (noturno), os controles realizados após duas, seis semanas e três meses. Nos retornos, os pacientes foram avaliados quanto a EAV (Escala de Análise Visual), abertura bucal ativa e algometria (exame para análise do limiar de dor a pressão (LDP) realizado com o auxílio de um algômetro da marca KRATOS capaz de medir a pressão em Kgf). Ainda foram avaliados possíveis efeitos colaterais como desconforto ao uso dos aparelhos oclusais. Os resultados foram analisados com os testes estatísticos: Teste Qui-Quadrado, Kruskal-Wallis, ANOVA e Turkey, adotando-se um nível de significância de 0,05. Os três grupos apresentaram melhora nos sinais e sintomas de DMF, sugerindo que o tratamento com aparelhos oclusais e técnicas de aconselhamento e mudanças comportamentais parece ser benéfico ao paciente. No entanto, o uso de aparelhos oclusais parece levar a uma melhora mais rápida. O tratamento através das placas estabilizadoras oclusais parece ser mais seguro e efetivo e os dispositivos NTI necessitam de mais estudos em longo prazo para confirmar sua eficácia, assim como a ausência de efeitos adversos. / The aim of this research was to test the hypothesis that the treatment with intraoral appliances with different occlusal designs is beneficial in the management of symptoms and signs of masticatory Myofascial Pain (MMP) when compared to a control group. 51 patients were analyzed according to the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/ TMD) in order to obtain the diagnostic of Myofascial Pain. Then the sample was randomly divided into three groups: 21 patients were treated with acrylic stabilization occlusal splint ; 16 received an anterior device (NTI (Nociceptive Trigeminal Inhibitory System)) and 14 patients received couseling and orientations for behavioral changes (control group). The two previous groups also received orientations and counseling. The devices were installed and weared in partial time (only during sleep), and the follow-ups were performed after 2, 6 weeks and three months. In these sessions, patients were evaluated according the visual scale of pain (VAS), maximum mouth opening and masticatory muscle algometry, able to determine the pain pressure threshold (PPT)(KRATOS, Brazil). Possible adverse effects were also analyzed such as comfort in the use of the appliance and occlusal alterations. The results were analyzed with Chi-Square test, Kruskal-Wallis, ANOVA and Turkey, with significance level of 5%. The three groups showed improvement in signs and symptoms of MMP, suggesting that occlusal appliances and behavioural orientations may be benefical in the treatment of this condition. However, the management with occlusal appliance and orientations seems to have an earlier effect. Long term studies with the NTI device are needed to establish its safety and absence of adverse dental effects.
112

Ajustes das características eletroacústicas do aparelho de amplificação sonora individual com base em limiares auditivos tonais e resposta auditiva de estado estável / Hearing AID prescription based on audiometric thresholds and auditory steady state responses

Bosso, Janaina Regina 07 April 2009 (has links)
A impossibilidade de obtenção de dados audiológicos comportamentais em crianças deficientes auditivas faz com que seja necessária a utilização de testes objetivos como a resposta auditiva de estado estável (RAEE) para estimar os limiares auditivos. O objetivo deste estudo foi verificar as diferenças encontradas na seleção de características eletroacústicas do aparelho de amplificação sonora individual (AASI) com base nos limiares auditivos estimados por meio da resposta auditiva de estado estável (RAEE) em comparação com o mesmo processo realizado com base em limiares auditivos tonais. Foram estudados 28 indivíduos com deficiência auditiva neurossensorial: grupo A, composto por 10 adultos (média da idade 46,3 anos) e grupo B, composto por 18 crianças (média da idade 10,38 anos). O método prescritivo utilizado foi o Desired Sensation Level (DSL) i/o versão 4.1. A medida individualizada da RECD foi utilizada como transformador acústico. Três diferentes programações foram geradas considerando os limiares auditivos tonais nas freqüências de 0,25 a 6kHz (programação tonal completa - ProTC), os limiares auditivos tonais apenas nas freqüências de 0,5, 1, 2 e 4 kHz (programação tonal - ProT) e os limiares auditivos estimados na RAEE nas freqüências de 0,5, 1, 2 e 4 kHz (programação eletrofisiológica - ProE). A verificação da amplificação foi realizada em acoplador de 2cc. Foi realizada avaliação da percepção da fala na presença de ruído (grupo A e B) e julgamento da qualidade sonora (grupo A). Os resultados mostraram que os valores da resposta em orelha real amplificada prescrita (REAR P) foram maiores para programação baseada em limiares auditivos estimados pela RAEE. As diferenças encontradas foram significativas, para todas as intensidades testadas, nas freqüências de 0,5, 1 e 2 kHz no grupo A e em todas as freqüências no grupo B. A diferença entre a REAR P e a REAR medida em acoplador de 2cc (REAR M) foi inferior a 1,4 dB em todas as freqüências e intensidades estudadas, para os grupos A e B. Não foram encontradas diferenças entre a REAR M obtidas na ProTC e na ProT. Os valores de REAR M obtidos na ProE foram maiores do que os obtidos nas programações ProTC e ProT. Não foram encontradas diferençam significativas na avaliação da percepção da fala em adultos. Por outro lado, em crianças, foi encontrada diferença significativa na obtenção da relação sinal/ruído na ProE quando comparada com às programações ProTC e ProT. No julgamento da qualidade sonora, os resultados mostraram pior julgamento das dimensões avaliadas, na ProE. Entretanto apenas para a dimensão conforto auditivo foi encontrada diferença significativa. O resultado do presente estudo mostra que os limiares auditivos estimados pela RAEE podem ser utilizados na determinação das características eletroacústicas do AASI em adultos e crianças. / The impossibility for obtaining behavioral auditory data in children with hearing loss brings the necessity of applying objective tests as auditory steady state responses (ASSR) in order to evaluate the auditory thresholds. The objective of this study was to verify the differences found on the selection of the eletroacoustic characteristics of the hearing aid (AASI) based on the auditory thresholds, obtained by the auditory steady state responses (ASSR) in comparison with the same procedure realized, based on audiometric thresholds: A total of 28 people with sensorineural hearing loss were studied: group A comprised 10 adults (average age 46,3 years) and group B comprised 18 children (average age 10,38 years). The prescriptive method applied was Desired Sensation Level (DSL) i/o version 4.1. The individualized measurement of RECD was applied as acoustic transformer. Three different programs were generated considering the audiometric thresholds on the frequencies from 0,25 to 6kHz (complete tonal program- ProTC), the audiometric thresholds just on the frequencies 0,5, 1, 2 and 4 kHz (tonal program- ProT) and the auditory thresholds obtained by the ASSR on the frequencies 0,5, 1, 2 and 4 kHz (electrophysiological program ProE). The verification of the amplification was realized by a coupler of 2cc. The evaluation of speech recognition in noise (group A and B) and the judgment of sound quality (group A) was performed. The results showed that the Real Ear Aided Response prescribed (REAR P) were higher for the program based on the auditory thresholds estimated by the ASSR. The differences were significant, for all the levels of intensity tested, for the frequencies 0,5, 1, 2 and 2 kHz in group A and in all the frequencies in group B. The difference between REAR P and the REAR measured in coupler of 2cc (REAR M) was lower than 1,4dB for all the frequencies and intensities studied, for groups A and B. Differences were not found between the REAR M obtained on the ProTC and ProT. The results for REAR M obtained on the ProE were higher than the ones obtained on the programs ProTC and ProT. Significant differences were not found in the evaluation for the speech perception in adults. For children, significant differences were found for S/N on the ProE when compared to the program ProTC and ProT. On the evaluation of the sound quality, the results showed worse judgment of the dimensions evaluated, on the ProE. However, a significant difference was found for auditory comfort dimension. The outcomes of the present study shows that the auditory threshold obtained by the ASSR can be employed for the determination of the electroacoustic characteristics of the hearing aids in adults and children.
113

Desenvolvimento de um sistema opto-mecânico para micro usinagem com laser de femtosegundos / Development of an opto-mechanical system for micro machining with femtosecond laser

José Tort Vidal 08 June 2010 (has links)
A usinagem de estruturas micrométricas pode ser feita com pulsos laser de nano, pico ou fentossegundos. Destes, porém, somente os mais curtos podem resultar em uma interação não térmica com a matéria, o que evita a fusão, formação de rebarba e zona afetada pelo calor. Devido à sua baixa potência média, contudo, a sua utilização na produção em massa somente pode ser considerada em casos muito especiais, isto é, quando o processamento não-térmico é essencial. Este é o caso da usinagem de semicondutores, aços elétricos, produção de MEMS (sistemas micro eletro-mecânicos), de micro canais e diversos dispositivos médicos e biológicos. Assim, visando a produção destes tipos de estruturas, uma estação de trabalho foi construída com capacidade de controlar os principais parâmetros de processo necessários para uma usinagem micrométrica com laser de pulsos ultracurtos. Os principais problemas deste tipo de estação são o controle da fluência e do posicionamento do ponto focal. Assim, o controle do diâmetro do feixe (no foco) e da energia devem ser feitos com grande precisão. Além disso, o posicionamento do ponto focal com precisão micrométrica nos três eixos, também é de fundamental importância. O sistema construído neste trabalho apresenta soluções para estes problemas, utilizando diversos sensores e posicionadores controlados simultaneamente por um único programa. A estação de trabalho recebe um feixe vindo de um laser de pulsos ultracurtos localizado em outro laboratório, e manipula este feixe de maneira a focalizá-lo com precisão na superfície da amostra a ser usinada. Os principais parâmetros controlados dinamicamente são a energia, o número de pulsos e o posicionamento individual de cada um deles. A distribuição espacial da intensidade, a polarização e as vibrações também foram medidas e otimizadas. O sistema foi testado e aferido com medidas de limiar de ablação do silício, que é um material bastante estudado neste regime de operação laser. Os resultados, quando confrontados com a literatura, mostram a confiabilidade e a precisão do sistema. A automatização, além de aumentar esta precisão, também aumentou a rapidez na obtenção dos resultados. Medidas de limiar de ablação também foram realizadas para o metal molibdênio, levando a resultados ainda não vistos na literatura. Assim, de acordo com o objetivo inicial, o sistema foi desenvolvido e está pronto para utilização em estudos que levem à produção de estruturas micrométricas. / Machining of very small structures has been made with nano, pico and femtosecond pulsed lasers. Among then, only femtosecond lasers may result in nonthermal interaction with matter, avoiding melting, formation of slag and heat affected zone. Mass production with such lasers yet can only be considered in cases where nonthermal effects are of prime importance. This is the case in machining of semiconductors and electric steels, the production of MEMS, microchannels, and many medical and biological devices. Hence, a workstation for production of such kind of microstructures was built with the capability of controlling the main parameters necessary for the machining process. Control of the laser fluence and focus positioning are the main concern in this kind of processing. So, the control of the laser beam diameter (in the focus) and of the pulse energy must be very precise. Positioning of focal point with micrometric precision in the three axes is also fundamental. The system built in this work provides solutions for these problems incorporating several sensors and positioning stages simultaneously controlled by a single software. The workstation receives a laser beam coming from another laboratory and delivers it to the surface of the sample managing with precision the main process parameters. The system can dynamically control the energy, number of pulses and positioning for each individual laser spot. Besides, the spatial distribution of the laser intensity, polarization and vibrations were also measured and optimized. The system was tested and calibrated with threshold ablation measurement for silicon, which is well studied in this regime of laser operation. The results where compared with data found in the literature and attested the reliability and precision of the system. Besides the increase in precision, the automation also turned much faster the data acquisition. Threshold ablation for metallic molybdenum was also obtained and resulted in data not found in the literature yet. Concluding the initial goal, the workstation was developed and is ready to be used in studies that can lead to production of micrometric structures.
114

Limiar ventilatório dois (LV2) e o consumo máximo de oxigênio (VO2max) como preditores de tolerância ao esforço em jogadores de futebol / Ventilatory threshold two (VT2) and maximal oxygen uptake (VO2max) as predictors of tolerance for effort in male soccer players

Silva, Paulo Roberto dos Santos 02 September 2009 (has links)
O objetivo deste estudo foi verificar a relação entre o limiar ventilatório dois (LV2) e o consumo máximo de oxigênio (VO2max) como preditores de tolerância ao esforço em jogadores de futebol. O LV2 e o VO2max foram medidos a um terço de encerramento da temporada. Uma amostra de sessenta atletas futebolistas do sexo masculino, distribuídos nas seguintes posições: (14 zagueiros [23%], 14 laterais [23%], 19 meio campistas [32%] e 13 atacantes [22%]) menos os goleiros. A média de idade era de 20,8 ± 2,8 anos; massa corpórea de 71,9 ± 7,6 kg e estatura de 178 ± 6,5 cm foram avaliadas num estudo transversal. Todos eram assintomáticos, não fumantes, não faziam uso de qualquer medicamento e eram livres de qualquer tipo de distúrbio neuromuscular, cardiovascular, respiratório e circulatório. A média de treinamento no período competitivo consistiu de 10 horas semanais. Todos os jogadores eram de clubes profissionais da primeira divisão do Estado de São Paulo e estavam registrados na Federação Paulista de Futebol.Todos foram submetidos à avaliação cardiorrespiratória e metabólica, utilizando-se analisador metabólico de gases (CPX/D, MedGraphics, EUA) acoplado a eletrocardiógrafo (Max Personal, Marquette, EUA), ambos os sistemas computadorizados. A determinação da capacidade física máxima foi verificada em esteira rolante (Inbramed, ATL10200, BRA) utilizando-se protocolo escalonado contínuo (1 km.h-1 a cada dois minutos) e inclinação fixa de 3%. Os seguintes resultados verificados e os parâmetros utilizados foram: VO2max = 58,8 ± 4,48 mL.kg-1.min-1; VO2LV2 = 49,6 ± 4,96 mL.kg-1.min-1; TTMAX = 1073 ± 124,5s; TTLV2 = 713 ± 106,0s. Análise de regressão linear demonstrou correlação positiva entre o TTMAX vs. VO2max (r = 0,473;p<0,001); VO2LV2 vs. VO2max (r = 0,691; p<0,001); TTLV2 vs. VO2max (r = 0,545; p <0,001); TTMAX vs. TTLV2 (r = 0,560; p < 0,001) e entre TTLV2 vs. VO2LV2 (r = 0,610; p< 0,001). Concluindo, a potência aeróbia máxima associada ao aumento do consumo de oxigênio no LV2, são preditores de uma maior capacitação aeróbia em jogadores de futebol. O melhor parâmetro preditor de tolerância ao exercício em todas as posições foi à relação VO2LV2 vs. VO2max. / The aim of this study was to investigate the relationship between the ventilatory threshold two (VT2) and maximum oxygen consumption (VO2max) as predictors of exercise tolerance in soccer players. VT2 and VO2max were measured when one-third of the soccer season still remained. A sample of sixty male soccer players, distributed in the following position: (14 central-defenders [23%], 14 fullbacks [23%], 19 midfielders [32%] and 13 forwards [22%]) less the goalkeepers, were evaluated a cross-sectional study. The mean age was 20.8 ± 2.7 years, body mass: 71.9 ± 7.62 kg and height: 178.1 ± 6.5 cm. All were asymptomatic, non-smokers, they did not use any medication and were free from any kind of neuromuscular disorder, cardiovascular, respiratory and circulatory. In the competitive season, the average training week consisted of 10 hours practice and games. All the players were professional clubs of the first division of the State of Sao Paulo and were registered in the Paulista Football Federation. All of them underwent a cardiopulmonary and metabolic exercise test evaluation. To this end we used a gas explorer (CPX/D, breathbybreath Medgraphics, Saint Paul, MN, USA) coupled to an electrocardiograph (Max Personal, Exercise Testing System, Marquette, USA). Both systems were computerized. The maximum exercise test was performed on a motor-driven treadmill (Inbramed, ATL-10200, Porto Alegre, BRA), using the incremental continuous exercise protocol. The athletes started the race with 8 km.h-1 and increased speed of 1 km.h-1 every two minutes with fixed slope at 3%. In all tests there was verbal encouragement. The results verified and the parameters used were: VO2max = 58.8 ± 4.48 mL.kg-1.min-1; VO2VT2 = 49.6 ± 4.96 mL.kg-1.min-1; MAXTT = 1073 ± 124.5s; TTVT2 = 713 ± 106s. Linear regression analysis in male soccer players showed positive correlation between the VO2max vs. MAXTT to exercise (R = 0.473; p < 0.001); VO2VT2 vs. VO2max (R = 0.691; p < 0.001); TTVT2 vs. VO2max (R = 0.545; p < 0.001); MAXTT vs. TTVT2 (R=0.560; p < 0.01) and between TTVT2 vs. VO2VT2 (R=0.610; p < 0.001). The results allowed us to infer that the attainment of maximum aerobic power together with increased of VO2VT2 are predictors of a higher aerobic capacity in soccer players. The best predictive parameter of exercise tolerance in all positions was the relationship VO2VT2 vs. VO2max.
115

Desenvolvimento de um sistema opto-mecânico para micro usinagem com laser de femtosegundos / Development of an opto-mechanical system for micro machining with femtosecond laser

Vidal, José Tort 08 June 2010 (has links)
A usinagem de estruturas micrométricas pode ser feita com pulsos laser de nano, pico ou fentossegundos. Destes, porém, somente os mais curtos podem resultar em uma interação não térmica com a matéria, o que evita a fusão, formação de rebarba e zona afetada pelo calor. Devido à sua baixa potência média, contudo, a sua utilização na produção em massa somente pode ser considerada em casos muito especiais, isto é, quando o processamento não-térmico é essencial. Este é o caso da usinagem de semicondutores, aços elétricos, produção de MEMS (sistemas micro eletro-mecânicos), de micro canais e diversos dispositivos médicos e biológicos. Assim, visando a produção destes tipos de estruturas, uma estação de trabalho foi construída com capacidade de controlar os principais parâmetros de processo necessários para uma usinagem micrométrica com laser de pulsos ultracurtos. Os principais problemas deste tipo de estação são o controle da fluência e do posicionamento do ponto focal. Assim, o controle do diâmetro do feixe (no foco) e da energia devem ser feitos com grande precisão. Além disso, o posicionamento do ponto focal com precisão micrométrica nos três eixos, também é de fundamental importância. O sistema construído neste trabalho apresenta soluções para estes problemas, utilizando diversos sensores e posicionadores controlados simultaneamente por um único programa. A estação de trabalho recebe um feixe vindo de um laser de pulsos ultracurtos localizado em outro laboratório, e manipula este feixe de maneira a focalizá-lo com precisão na superfície da amostra a ser usinada. Os principais parâmetros controlados dinamicamente são a energia, o número de pulsos e o posicionamento individual de cada um deles. A distribuição espacial da intensidade, a polarização e as vibrações também foram medidas e otimizadas. O sistema foi testado e aferido com medidas de limiar de ablação do silício, que é um material bastante estudado neste regime de operação laser. Os resultados, quando confrontados com a literatura, mostram a confiabilidade e a precisão do sistema. A automatização, além de aumentar esta precisão, também aumentou a rapidez na obtenção dos resultados. Medidas de limiar de ablação também foram realizadas para o metal molibdênio, levando a resultados ainda não vistos na literatura. Assim, de acordo com o objetivo inicial, o sistema foi desenvolvido e está pronto para utilização em estudos que levem à produção de estruturas micrométricas. / Machining of very small structures has been made with nano, pico and femtosecond pulsed lasers. Among then, only femtosecond lasers may result in nonthermal interaction with matter, avoiding melting, formation of slag and heat affected zone. Mass production with such lasers yet can only be considered in cases where nonthermal effects are of prime importance. This is the case in machining of semiconductors and electric steels, the production of MEMS, microchannels, and many medical and biological devices. Hence, a workstation for production of such kind of microstructures was built with the capability of controlling the main parameters necessary for the machining process. Control of the laser fluence and focus positioning are the main concern in this kind of processing. So, the control of the laser beam diameter (in the focus) and of the pulse energy must be very precise. Positioning of focal point with micrometric precision in the three axes is also fundamental. The system built in this work provides solutions for these problems incorporating several sensors and positioning stages simultaneously controlled by a single software. The workstation receives a laser beam coming from another laboratory and delivers it to the surface of the sample managing with precision the main process parameters. The system can dynamically control the energy, number of pulses and positioning for each individual laser spot. Besides, the spatial distribution of the laser intensity, polarization and vibrations were also measured and optimized. The system was tested and calibrated with threshold ablation measurement for silicon, which is well studied in this regime of laser operation. The results where compared with data found in the literature and attested the reliability and precision of the system. Besides the increase in precision, the automation also turned much faster the data acquisition. Threshold ablation for metallic molybdenum was also obtained and resulted in data not found in the literature yet. Concluding the initial goal, the workstation was developed and is ready to be used in studies that can lead to production of micrometric structures.
116

Estudo da distribuição de doses limiares em TFD para um modelo de cultura tridimensional de células obtido pelo método de levitação magnética / Study of the threshold doses distribution in PDT using the three-dimensional cell cultures obtained by the method of magnetic levitation

Sabino, Luis Gustavo 21 October 2014 (has links)
Um conceito central na dosimetria da terapia fotodinâmica (TFD) é o limiar de dose (Dth do inglês threshold dose). O Dth é definido como a quantidade mínima de luz que deve ser absorvida pelas moléculas de fotossensibilizador (FS) dentro das células malignas a serem tratadas para que ocorra a morte celular por necrose ou apoptose. Os resultados do estudo da captação de FS por células Hep G2 demonstraram que uma população celular de linhagem, cultivada em monocamada, apresenta captação de Photogem (PG) heterogênea, ou seja, algumas células têm maior capacidade de captar moléculas de PG, outras células captam o PG em menor quantidade. A captação heterogênea de PG pode ser a causa para fenômenos de seleção de células mais resistentes à TFD. É razoável supor que as subpopulações celulares de uma mesma massa de células malignas possam apresentar diferentes valores de Dth. Definiu-se uma função de distribuição das doses limiares (g()) como uma função de distribuição gaussiana, e para a sua parametrização desenvolveu-se um método para o cultivo in vitro de culturas tridimensionais (culturas 3D), mais fidedignas ao tecido neoplásico maligno que as culturas tradicionais. Utilizando-se o método de levitação magnética (MLM) e o método de impressão magnética (MIM) para a dosimetria da TFD, foi possível parametrizar a g(Dth), investigar a resistência celular à TFD. O MLM demonstrou ser facilmente manuseável na rotina experimental, e consistente para o teste in vitro de novos FS. Comparando-se as culturas MDA-MB-231e Hep G2, obtidas por MLM por mais de 185 horas de levitação, pode-se concluir que as células Hep G2 formaram uma estrutura celular mais densa e que ofereceu mais resistência ao dano causado pela TFD. É notável como as células Hep G2 retomaram o crescimento, e restabeleceram-se em cultura de modo semelhante ao grupo controle, por meio da reconstrução da matriz extracelular (MEC). Enquanto isso, no caso das células MDA-MB-231, a integridade da cultura não foi restabelecida após a aplicação da TFD, formando uma cultura fragmentada. O dano mais evidente, para ambas as culturas, foi observado nas margens dos tumores, evidenciando que os componentes importantes da reação fotodinâmica, como o fotossensibilizador, a luz e o oxigênio, estavam presentes em maiores quantidades na superfície da cultura, em comparação às outras regiões tumorais. Os resultados obtidos demonstram que para o Photogem (PG) é necessária uma fluência de luz da ordem de 40 J.cm-2, para que o efeito fotodinâmico promova morte celular nas culturas 3D obtidas pelo MLM. O resultado da combinação de dois tipos celulares, o maligno (MDA-MB-231) e o sadio (HPF), demonstrou que o efeito fotodinâmico é efetivo quando se tem controle adequado da entrega dos agentes da terapia, independentemente do tipo celular. Algumas células sobreviveram ao tratamento, e existe um forte indicativo de que a presença de fibroblastos HPF esteja relacionada a esta pequena parcela de células que receberam dose de luz inferior ao seu Dth. Os resultados demonstraram que quanto maior a fluência de luz, menor é o IC50 do PG. Para a fluência de luz de 60 J.cm-1 obteve-se um IC50 de 3,1 &mu;g.mL-1, e para a fluência de luz de 30 J.cm-1 obteve-se um IC50 de 18,0 &mu;g.mL-1. / Photodynamic therapy (PDT) dosimetry includes a central concept: the threshold dose (Dth), which is the minimum amount of light to be absorbed by the photosensitizer (PS) molecules to induce irreversible oxidative damage, and hence to cause cell death by necrosis or apoptosis. It is reasonable to assume that cells subpopulation in one individual tumor cell mass may present different Dth values, which implies the existence of a distribution of Dth values defined by a Gauss distribution function (g(Dth)). Developing methods for more realistic tissue emulation with in vitro cultures, such as three-dimensional (3D) cultures, have been encouraged aiming to avoid the above-mentioned dissimilarities. A 3D cell culture is preferable compared to monolayer cell cultures, because it provides cell-cell and cell-substrate interaction, and makes evaluating a culture and its volumetric dimension (which resembles the tumor morphology) possible. This study also includes the development of a 3D model, using the magnetic levitation method (MLM) and the magnetic printing method (MIM, from Portuguese método de impressão magnetic) for PDT dosimetry. The aim is to define parameters for g(Dth), to investigate cell resistance to PDT, and to achieve a fast and consistent method for new PS in vitro tests. By comparing cultures from the different cell types studied, the ones obtained by MLM for more than 185 hours were found to present a denser cellular structure, which provided improved resistance to PDT-induced damage. Hep G2 cells showed a remarkable behavior by being able to recover culture integrity; meanwhile MDA-MB-231 cells were not able to do so. The most evident damage, for both cell culture types, was observed on tumor margins, showing that the main elements to play a role in PDT reaction (PS, light and oxygen) were present in larger quantities, at culture surface, when compared with internal regions of the cell culture. Results obtained for PG show that a light fluence of about 40 J.cm-2 is required to induce cell death by photodynamic effect on 3D cells obtained by MLM. A combination of two different cell types - a tumor cell line and a healthy cell line - shows clearly that there is no difference for the photodynamic outcome if one holds enough control on the therapeutic parameters. The results presented in this thesis show that even a strain cell population, grown in a monolayer cell culture, results in a non-homogeneous PG uptake, which means that part of the cells seems to be able to collect PG molecules more efficiently than other cells. This difference in collection among cells may be the cause of a selection of cells that are more \"resistant\" to PDT. There were cells that survived treatment, and the presence of HPF fibroblasts might be the cause of these surviving cells, since their Dth might have not been achieved. The results showed that as higher is the light fluence, as lower is the IC50 of PG. The fluence of 60 and 30 J.cm-1 resulted in IC50 of 3.1 and 18.0 &mu;g.mL-1, respectively.
117

Estudo do desencadeamento das erosões lineares concentradas em uma área do município de São Pedro/SP / Study of the trigger of concentrated gully erosion in an area of São Pedro/SP

Araujo, Thiago Peixoto de 02 May 2011 (has links)
O presente trabalho propõe índices que indicam o limiar topográfico para predição do desencadeamento de canais de erosão linear em uma região de clima tropical. A área escolhida para a realização do estudo localiza-se no município de São Pedro/SP e apresenta uma área de aproximadamente 7 \'KM POT.2\'. Nesta área foi realizado um inventário detalhado das feições erosivas pré-existentes para obtenção dos valores das áreas das bacias de contribuição, considerando as cabeceiras de algumas erosões e as declividades médias dessas áreas, por meio de ferramentas de SIG e também por fotografias aéreas ortorretificadas. Trabalhos de campo, com o auxílio de GPS de precisão, permitiram definir a situação atual das erosões e com o uso de fotografias aéreas de anos anteriores foi possível observar a sua evolução. Com isso, através dos mapas em SIG, como MDT, declividade, direção de fluxo e etc. foram obtidos os valores de área de contribuição (A) e declividade média (S). Os valores de A x S foram apresentados em gráficos que permitiram identificar o ponto mínimo para a ocorrência de um evento erosivo e estabelecer de forma empírica os limiares topográficos que definem as condições para o início do processo erosivo. Para o Índice I foram feitas duas equações (uma para canais menos profundos que 1 metro e outra para canais mais profundos que 1 metro) e para o Índice II foi obtida apenas uma equação, pois em fotografias aéreas nas escalas disponíveis (1:25.000 e 1:30.000) foram possíveis serem observados apenas os canais profundos. Os índices obtidos neste trabalho foram para o Índice I: S = 0,0219A(-0,376) (canais profundos) e S = 0,0128A(-0,443) (canais rasos); enquanto que para o Índice II o valor obtido é: S = 0,0588A(-0,377). Para a validação destes índices propostos, foram realizados os mesmos procedimentos para obtenção das áreas de contribuição (A) e declividade média (S), porém em outra área. A área escolhida para se fazer a validação dos índices foi a Bacia do Ribeirão do Meio, que apresenta 48 \'KM POT.2\' aproximados de área e apresenta características físicas semelhantes da área utilizada neste presente estudo, ou seja, apresenta semelhança em geologia, geomorfologia, clima, uso e ocupação. Foi observado com esta validação, que todos os pontos com problemas de erosão da área usada para validação localizam-se dentro da área prevista pelos índices para ocorrência de problemas de erosão, o que significa dizer que os índices exprimem o limiar topográfico para erosões lineares nas condições encontradas na área de estudo e em áreas semelhantes. / This paper proposes indexes indicating the topographic threshold for predicting the trigger of gully erosion in a tropical climate region. The area chosen for the study is located in São Pedro/SP and presents an area of approximately 7 \'KM POT.2\' . In this area was carried out a detailed inventory of pre-existing erosion to obtain the values of watershed areas of contribution, considering the headwaters of some erosions and the mean slope of these areas, using GIS tools and also orthorectified aerial photographs. Fieldwork, with the assistance of GPS accuracy, allowed defining the current condition of erosion and with the use of aerial photographs from previous years was possible to observe its evolution. Thus, through the maps in GIS, as DEM, Slope, Flow Direct ion among others, were obtained values from contribution area (A) and mean slope (S). The values of A x S were represented in charts al lowing to identify the lower point for the occurrence of an erosion event and establish empirical ly the topographic thresholds that def ine the conditions for initiating the erosion process. For the index I were made two equations (one for channels less than 1 meter deep and one for channels deeperthan 1 meter) and Index II was obtained only one equation, because in aerial photographs available (scales1:25,000 and 1:30,000) were possible only be observed the deep channels. The indexes obtained in this paper were for the Index I: S = 0,0219A(-0,376) (deep channels) and S = 0,0128A(-0,443) (shallow channels), while the index II the value obtained is: S = 0,0588A(-0,377). To validate these proposed indexes, the same procedures were performed to obtain the contribution area (A) and mean slope (S), but in another area. The area chosen to perform the validation of the indexes was the Basin Ribeirão do Meio, which is 48 \'KM POT.2\' extents and shows similarity in geology, geomorphology, climate, use and occupation. The results have been showed that the selected points with erosion problem of the area used for validation are located wi thin the area specified by the indexes for the occurrence of erosion problems, which means that the indexes reflect the topographic threshold for gully erosions in conditions found in the study area and similar areas.
118

Avaliação da sensibilidade cutânea na mão de pacientes com síndrome do túnel do carpo associada à hemodiálise, antes e após tratamento cirúrgico / Cutaneous sensibility testing in patients in chronic hemodialysis associated to carpal tunnel syndrome before and after surgical decompression

Nakamoto, Hugo Alberto 18 September 2012 (has links)
A síndrome do túnel do carpo é a neuropatia compressiva mais comum do membro superior. Cerca de 5% dos pacientes com insuficiência renal crônica submetidos à hemodiálise apresentam esta condição. A história clínica e o exame físico continuam sendo as ferramentas mais adequadas para seu diagnóstico. Testes complementares têm sido usados para auxiliar o diagnóstico e o controle de tratamento; dentre eles os de avaliação da sensibilidade cutânea. O PSSD (Pressurespecified sensory device ) consiste de aparelho que incorpora transdutor de pressão acoplado a um computador capaz de determinar os limiares cutâneos de sensibilidade à pressão no território do nervo mediano(superfície volar do índex). O objetivo do estudo foi determinar através do PSSD os limiares cutâneos de pressão no território do nervo mediano antes e depois do tratamento cirúrgico da síndrome. Para tanto, os pacientes foram divididos em dois grupos: Grupo 1: pacientes portadores de insuficiência renal crônica e submetidos à hemodiálise com síndrome do túnel do carpo. Grupo 2: pacientes com síndrome do túnel do carpo sem insuficiência renal. Foram avaliados com o PSSD as seguintes medidas: limiares cutâneos de pressão no teste de um ponto estático, no teste de um ponto dinâmico, no teste estático de dois pontos e no teste dinâmico de dois pontos. Houve evolução positiva no pós operatório(menor limiar) de todos os parâmetros avaliados pelo PSSD no grupo 1, enquanto no grupo 2 houve melhora significativa em todos os parâmetros, excetuando-se os do teste dinâmico de um ponto / Carpal Tunnel Syndrome is the most common compressive neuropathy on the upper limb. About 5% of the patients with chronic renal insufficiency who are treated with hemodialysis present carpal tunnel syndrome. Clinical history and physical examination remain the most adequate tools for the diagnosis. Evaluation of sensory thresholds can be used to complement those parameters. The PSSD (Pressurespecified sensory device) is a tool that incorporates a pressure transducer linked to a computer capable of measuring the cutaneous pressure thresholds referred by the patient. The aim of this study was to determine the values of pressure thresholds with the PSSD before and after treatment of carpal tunnel syndrome. The patients were divided in two groups: Group 1: patients with carpal tunnel syndrome associated to chronic hemodialysis. Group 2: patients with carpal tunnel syndrome without renal insufficiency. The following measurements were performed: static one point, moving one point, static two points and moving two points. The results showed better results in the post operative measurements in all parameters assessed in group 1, and improvements in all parameters with exception of the moving one point test in group 2
119

Titulação do limiar convulsígeno e segurança cardiovascular / Titration seizure threshold and cardiovascular safety

Bueno, Celso Ricardo 13 November 2009 (has links)
A Eletroconvulsoterapia (ECT) é o tratamento biológico mais eficaz para quadros depressivos. Os estudos de seus aspectos técnicos são fundamentais tanto para compreensão dos mecanismos da ECT quanto para maximizar a eficácia e minimizar seus efeitos cognitivos. Existem muitos métodos para o cálculo da dose do estímulo elétrico e não há consenso em relação ao melhor. Sabe-se que doses muito elevadas tendem a ser eficazes, mas à custa de efeitos na memória. Embora o método de titulação seja recomendado pela Associação Psiquiátrica Americana, muitos profissionais tem preocupação sobre a segurança cardiovascular deste procedimento, devido aos sucessivos estímulos frustros que levam a um aumento na incidência de bradicardia e/ou assistolia. O objetivo deste trabalho foi traçar o perfil dos pacientes submetidos ao método da titulação do limiar, verificando sua segurança cardiovascular. Para isso foi feito um estudo retrospectivo e 113 casos foram revistos no ano de 2007. A maioria (70,3%) recebeu aplicação bilateral e (62,8%) eram mulheres. O diagnóstico de depressão apareceu com mais freqüência (50,5%). A maioria (57,5%) necessitou de dois estímulos, (12,4%) necessitou de apenas um, (28,3%) necessitou de três e (1,8%) realizou quatro estímulos. A média de frequência cardíaca inicial foi de 79,6 bpm (DP = 17). O limiar convulsígeno variou de 16mC a 128mC (média = 58,9; DP 25,4). A relação do limiar convulsígeno foi significativamente menor com o posicionamento unilateral dos eletrodos (p < 0,001), mas não com sexo ou idade. Não foi encontrada associação com a medicação concomitante. A incidência de bradicardia aumentou com os estímulos frustros, mas não foi significante a relação entre o primeiro e segundo estímulos. Não houve complicações cardíacas significativas e nenhum paciente apresentou assistolia. Conclui-se que o método da titulação do limiar pode ser uma estratégia segura e mais precisa, uma vez que os fatores (sexo, idade e uso de medicamentos) não foram relacionados com o LCT; a baixa incidência de complicações cardiovasculares reforça-o como método de escolha. Não se pode descartar um efeito protetor do uso da atropina. / Electroconvulsive therapy (ECT) is the most effective biological treatment for depression. Studies of the technical aspects are fundamental for understanding the mechanisms of ECT and to maximize efficiency and minimize their cognitive effects. There are many methods to determine the dose of electrical stimulation and there is no consensus on which is the best one. It is known that very high doses are effective, but at the expense of effects on memory. Although the method of limits (titration method) is generally accepted, being encouraged by the American Psychiatric Association, many practitioners have concerns regarding cardiac safety of this method. Due to repetitive subthreshold stimuli until the seizure is elicited, an increased risk of bradiarrhythmia and/or asystole is believed to be present. The objective of this study was to establish the profile of patients undergoing the method of titration of the threshold, checking their cardiovascular safety. A retrospective study was performed including 113 cases that receive their treatment in the year of 2007. The majority (70.3%%) received bilateral ECT, (62.8%) were women. The diagnosis of depression appeared more frequently (50.5%). The majority (57.5%) needed two stimuli; 12.4% needed only one; 28.3% needed three and 1.8% required four stimuli. The average initial heart rate was 79.6 bpm (SD = 17). The seizure threshold ranged from 16mC to 128mC (mean = 58.9, SD 25.4). The ratio seizure threshold was significantly lower with unilateral electrode placement (p <0.001) but not with sex or age. No association was found with concomitant medication. There was an increased incidence of bradycardia with subthreshold stimuli , but there was not a relationship between the first and second stimuli. There were no significant cardiac complications and no patient had asystole. In conclusion, the method of titration of the threshold seems to be a safe and more precise to determined electrical dose, since the factors usually used to predict the threshold (gender, age and medication use) were not related to the LCT The low incidence of cardiovascular complications adds up to its use as the method of choice.. A protective effect of atropine cannot be ruled out.
120

Avaliação do sinal eletromiográfico como parâmetro para determinação do limiar de fadiga muscular / Evaluation of the eletromyographic signal as paameter for determination of muscle fatigue threshold

Azevedo, Fábio Micolis de 01 October 2007 (has links)
Embora a analise no domínio da freqüência do sinal Eletromiográfico (EMG) seja empregada na caracterização do processo de fadiga muscular localizada sua aplicação, especificamente a da Freqüência Mediana (Fmed), é pouco explorada para a determinação do Limiar de Fadiga Eletromiográfico (LFE). Neste estudo foram realizadas análises baseadas em procedimentos experimentais executados em três diferentes modalidades de exercício: i) isométrico; ii) isotônico com peso fixo; iii) isotônico no cicloergômetro; onde foi monitorado o comportamento da Fmed do sinal EMG em três porções do músculo quadríceps femoral: vasto lateral, vasto medial e reto femoral. Os resultados demonstraram ser possível determinar o LFE através da monitoração da Fmed, em qualquer modalidade de exercício para todas as três porções musculares avaliadas. Entretanto, para o exercício isométrico e isotônico com peso fixo a qualidade dos ajustes, utilizados para o calculo do LFE, apresentou melhores índices estatísticos em comparação com os resultados obtidos no cicloergômetro. Pode ser considerado um reflexo deste comportamento a menor variação nos valores do LFE observada nas duas primeiras modalidades de exercício. Por conseqüência, nestas modalidades, uma melhor caracterização do LFE, relacionada sua definição teórica, foi observada. A análise complementar das bandas de freqüência isoladas demonstrou a possibilidade de melhoramentos relacionados ao processo metodológico de tratamento do sinal EMG para determinação do LFE. Entende-se que a determinação do LFE é uma temática controversa, porém ao mesmo tempo apresenta um grande potencial de exploração científica caracterizando, neste contexto, a contribuição deste estudo para a área / Tthough the analysis in the frequency domain of the Electromyographic Signal (EMG) was used in the characterization of the localized muscular fatigue process their application, specifically the Median Frequency (MF), is rarely explored for the determination of Electromyographic Fatigue Threshold (EMGFT). In this study analysis based in experimental procedures were executed in three different modalities of exercise: i) isometric; ii) dynamic with fixed load; iii) dynamic in the cycle ergometer; where was monitored the behavior of the EMG signal through the MF in three portions of the quadriceps muscle: vastus lateralis, vastus medialis and rectus femoris. The results demonstrated that the determination of EMGFT through the monitorization of MF was possible, in any modality of exercises for all the three muscular portions evaluated. However for the isometric and dynamic exercise with fixed load the quality of the adjustments, used for estimate the EMGFT, presented better statistical index in comparison with the results obtained in the cycle ergometer. May be considered a reflex of this behavior the smallest variation in the values of EMGFT observed in the first two modalities of exercise. For consequence, in these modalities, a better characterization of EMGFT was observed when related with your theoretical definition. The complemental analysis of the isolated bands of frequency demonstrated the possibility of improvement related in the methodological process of EMG signal processing for determination of EMGFT. The understanding around the determination of EMGFT demonstrated a controversial theme, however at the same time it presents a great potential of scientific exploration characterizing, in this context, the contribution of present study for this area

Page generated in 0.0592 seconds