• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 393
  • 140
  • 74
  • 72
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 686
  • 277
  • 276
  • 276
  • 276
  • 212
  • 191
  • 190
  • 62
  • 50
  • 49
  • 48
  • 47
  • 47
  • 47
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Telemedicina teleradiologia

Barros Júnior, Euclides de Moraes January 2000 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-17T23:01:35Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T18:05:36Z : No. of bitstreams: 1 171202.pdf: 7803752 bytes, checksum: 572222489e3c3b716221090eff88e998 (MD5) / O objetivo deste trabalho é mostrar o sistema de Sala de Laudos Virtual, como tema de dissertação do curso de Pós-Graduação da Universidade Federal de Santa Catarina. Este sistema permite equipes médicas radiológicas acessarem banco de imagens em conformidade ao padrão DICOM 3.0 (Digital Image Communications in Medicine), provenientes de equipamentos radiologicos, disponibilizar estas imagens com outros médicos localizados geograficamente distantes, utilizando a tecnologia Internet existente para a elaboração conjunta do laudo e diagnóstico dos pacientes, através de um editor de laudos, ferramentas de manipulação de imagens compartilhadas entre os participantes da Sala de Laudos Virtual e um canal de áudio conferência. Este ambiente permite um melhor diagnóstico em casos difíceis, utilizando-se de opiniões de outros especialistas, repercutindo em melhores tratamentos para os pacientes, os médicos não precisam estar fisicamente presentes nas salas de laudos de clinicas e hospitais e a não necessidade de impressão de chapas radiológicas, ocasionado com isto reduções de custos.
322

Programa de controle de qualidade para unidades de radiologia diagnóstica no Município de Florianópolis

Santos, Targino Rodrigues dos January 2000 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia de Produção. / Made available in DSpace on 2012-10-17T15:25:59Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T19:27:48Z : No. of bitstreams: 1 186711.pdf: 33267715 bytes, checksum: ff0c8551e834684e8dd1b1a537c74456 (MD5) / Partindo-se de um embasamento teórico a respeito da estrutura para realizar um exame radiológico (aspectos físicos, técnicas aplicadas, comportamento profissional de acordo com as normas e regulamentações), complementado com visitas às Unidades Radiológicas dos Hospitais, é apresentado um modelo de Programa de Controle de Qualidade para Unidades de Radiologia com o objetivo de corrigir os pontos falhos, reforçar os aspectos positivos e adaptar cada unidade às normas e regulamentações pertinentes à atividade.
323

Acurácia dimensional e visibilidade do canal mandibular na tomografia computadorizada de feixe cônico

Waltrick, Karen Borges 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T09:24:13Z (GMT). No. of bitstreams: 1 285114.pdf: 1107603 bytes, checksum: 98af1c441fcb1bf6610b33c83996e213 (MD5) / O presente estudo in vitro teve como objetivos verificar a acurácia de mensurações lineares para o planejamento de implantes nas imagens de tomografia computadorizada de feixe cônico (TCFC) obtidas com diferentes tamanhos de voxel, e analisar a visibilidade do canal mandibular nestas imagens. Doze hemimandíbulas humanas secas foram escaneadas com três tamanhos de voxels (0,2; 0,3 e 0,4mm) gerando 108 imagens transversais de TCFC, nas quais dois observadores realizaram 648 medidas e avaliaram a visualização do canal mandibular. A média geral dos erros de medição entre as medidas nas imagens e as medidas diretas (feitas por meio de paquímetro digital) foi de 0,23mm (DP± 0,20). As medidas de TCFC subestimaram as medidas diretas em 390 casos (60,2%). Todos os erros de medição encontrados foram inferiores a 1mm. De modo geral, não houve diferença estatisticamente significativa entre os erros de medição nos diferentes tamanhos de voxel e entre os observadores. Entre os dois observadores houve diferença estatisticamente significativa (p<0,05) apenas na medida em largura, nos dois sítios localizados mais posteriormente. Entre os diferentes tamanhos de voxel, houve diferença estatisticamente significativa (p<0,05) apenas para um dos observadores, em uma medida em altura, no sítio localizado na região do 1º molar. Foi possível visualizar o canal mandibular em todas as 108 imagens avaliadas. As imagens transversais de TCFC mostram-se aceitáveis para mensurações lineares na região posterior da mandíbula e com um alto desempenho na visualização do canal mandibular nos tamanhos de voxel 0,2; 0,3 e 0,4mm. Os resultados deste estudo apontam a opção por um tamanho de voxel de 0,3mm como sendo a mais propícia, pois conjuga boa qualidade da imagem e baixa dose de radiação. / The aims of the present in vitro study was to verify the accuracy of linear measurements for implant planning performed in cone beam computed tomography (CBTC) images obtained with different voxel sizes, and to analyze the visibility of the mandibular canal in these images. Twelve dry human hemimandible were scanned with three voxel sizes (0.2, 0.3 and 0.4 mm), generating 108 cross-sectional images in which two observers made 648 measurements and evaluated the visibility of the mandibular canal. The mean overall measurement errors between the measurements in the images and the direct measurements was 0.23 mm (SD ± 0.20). CBTC measurements underestimated the direct measurements in 390 cases (60.2%). All measurement errors were smaller than 1mm. Overall, no statistically significant difference between the measurement errors in different voxel sizes and among observers. Between the two observers, there was one statistically significant difference (p <0.05) in the width of two sites located more posteriorly in the mandible. Among the different voxel sizes, there was a statistically significant difference (p <0.05) for an observer at a height measured at the site located in the region of the first molar. It was possible to visualize the mandibular canal in all the 108 files evaluated. The cross-sectional images of CBCT are acceptable for linear measurements in the posterior mandible and with a high performance visualization of the mandibular canal in voxel sizes of 0.2, 0.3, and 0.4mm. The results show the option for a voxel size of 0.3 mm as the most suitable, because it combines good image quality and low radiation dose.
324

Métodos de imagem na avaliação vascular

Torres, Felipe Soares January 2012 (has links)
Resumo não disponível
325

Estudo comparativo entre análise cefalométrica radiográfica e exame polissonográfico para diagnóstico da síndrome da apnéia obstrutiva do sono

Silva, Emerson Luiz Costa da January 2001 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T16:56:19Z No. of bitstreams: 1 Dissertação Emerson Silva.pdf: 465656 bytes, checksum: 731640379127dce40ab114cd303d074c (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-16T18:02:03Z (GMT) No. of bitstreams: 1 Dissertação Emerson Silva.pdf: 465656 bytes, checksum: 731640379127dce40ab114cd303d074c (MD5) / Made available in DSpace on 2013-05-16T18:02:03Z (GMT). No. of bitstreams: 1 Dissertação Emerson Silva.pdf: 465656 bytes, checksum: 731640379127dce40ab114cd303d074c (MD5) Previous issue date: 2001 / O objetivo deste estudo foi comparar a eficiência do exame cefalométrico radiográfico em relação ao exame polissonográfico para o diagnóstico da Síndrome da Apnéia Obstrutiva do Sono (SAOS), em 60 pacientes com suspeita clínica da condição. Observou-se a confiabilidade dos dados obtidos na cefalometria, vez que esta vem sendo utilizada largamente no protocolo de exame de pacientes apnêicos, principalmente para a determinação dos sítios obstrutivos, servindo desta forma de guia terapêutico. Os resultados demonstraram não haver diferença estatisticamente significante no que diz respeito à capacidade diagnóstica da cefalometria radiográfica e do exame polissonográfico. A cefalometria radiográfica mostrou-se capaz de diagnosticar, satisfatoriamente, indivíduos portadores de SAOS (sensibilidade ? 91,5%). Por outro lado, a cefalometria radiográfica não se mostrou capaz em identificar, de forma satisfatória, indivíduos não portadores de SAOS (especificidade ? 38,5%). Por fim, como a cefalometria radiográfica apresentou alta sensibilidade na determinação dos sítios obstrutivos, concluímos que tal exame deve compor um protocolo, em associação ao exame polissonográfico, de procedimento diagnóstico para indivíduos portadores de SAOS. / Salvador
326

AVALIAÇÃO DA COMPRESSÃO DA IMAGEM DIGITAL DA TELERRADIOGRAFIA LATERAL NA REPRODUTIBILIDADE DA MARCAÇÃO DE PONTOS CEFALOMÉTRICOS / Evaluation of the compression of the Cephalometric Radiography digital images in the reproducibility of cephalometric Landmarks.

Duarte, Hená Elizeth Meireles 27 February 2008 (has links)
Made available in DSpace on 2016-08-03T16:31:12Z (GMT). No. of bitstreams: 1 Hena Elizeth1.pdf: 163468 bytes, checksum: 7331fee05880654fa8b7d97d71d3c202 (MD5) Previous issue date: 2008-02-27 / The photo-stimulable storage phosphor imaging plates sistem shows the images in the computer screen as a DICOM (digital image and comunication in medicine) format. This kind of imaging format uses a lot of memory space in the computer hard disc what turns its storage and file trasmition in the internet a dificult task. The aim of this study was to evaluate the efect of the JPEG compression in different qualities factors (100, 80 and 60) in the reproducibility of cephalometric points in lateral teleradiographies comparing with DICOM images. The sample of the study consistes of 120 digital lateral teleradiographies obtained from 30 individuals, in DICOM format. These images were converted in JPEG format. Three dentists expertized in orthodontist were calibrated and then were oriented to mark cephalometric points em each image using the XY coordinates system after random and blind the sample. This was repeated one month later. Intra-observer and interobserver reproducibility was calculated using the intra-class correlation test. Differences between the compression ratios were assessed using a one-way analysis of variance. The results showed that the points marcations were reproductible, except to the Orbital point in the X coordinate. The statisc analyse showed no difference between the files formats to each point and axis. The different JEPG qualities compression factors studied (100, 80 and 60) did not affected the reproducibility in cephalometric points marcation tested. / A imagem digital adquirida pelo sistema da placa de fósforo foto ativada é visualizada no monitor do computador em um formato denominado DICOM. Este formato ocupa muito espaço para armazenamento, o que dificulta o arquivamento e transmissão da imagem pela Internet. O objetivo deste estudo foi avaliar a influência da compressão JPEG, nos Fatores de Qualidade 100, 80 e 60 na reprodutibilidade da marcação de pontos cefalométricos em imagens de telerradiografias em norma lateral comparadas com o formato DICOM. A amostra consistiu de 120 imagens de telerradiografias em norma lateral obtidas a partir de 30 indivíduos, dos quais se obteve uma radiografia digital no formato DICOM. Essas imagens foram convertidas para o formato JPEG. Após o cegamento e randomização da amostra, três Ortodontistas calibrados marcaram a localização de 12 pontos cefalométricos em cada imagem utilizando o sistema de coordenadas X e Y. Esse procedimento foi repetido após 1 mês. A reprodutibilidade intra e inter observador foi calculada usando o teste de correlação intraclasse. Para comparação entre os grupos de compressão e DICOM na reprodutibilidade de marcação dos pontos utilizou se a Análise de Variância (ANOVA) a um critério para medidas repetidas. Os resultados mostraram que as marcações dos pontos cefalométricos foram bastante reprodutíveis, exceto para o ponto Órbita na coordenada X. Os diferentes formatos de arquivo mostraram estatisticamente iguais para cada ponto e eixo aferido. As compressões JPEG estudadas das imagens de telerradiografias em norma lateral não tiveram efeito na reprodutibilidade da marcação dos pontos cefalométricos testados.
327

Programa de proteção radiológica em um serviço hospitalar de radiologia

Huhn, Andréa January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Enfermagem, Florianópolis, 2014. / Made available in DSpace on 2015-03-18T21:05:52Z (GMT). No. of bitstreams: 1 332826.pdf: 2102752 bytes, checksum: 7cdd836ef226b67644e9273ac13f6932 (MD5) Previous issue date: 2014 / Estudo qualitativo, exploratório e descritivo que utilizou dados da observação não participante, entrevista semiestruturada e análise documental: do Memorial Descritivo, que contém o Programa de Proteção Radiológica (PPR) do serviço de radiologia de um hospital público de ensino do sul do Brasil e da legislação vigente no Brasil acerca do PPR e da proteção radiológica. Teve como objetivo geral analisar a implementação e o conhecimento da equipe multiprofissional de saúde sobre o PPR em um serviço hospitalar de radiologia. Os objetivos específicos foram: Comparar o PPR do serviço de radiologia hospitalar com o estabelecido na legislação vigente; Identificar a participação da equipe multiprofissional de saúde no PPR e Descrever a implementação do PPR pela equipe multiprofissional. O hospital foi escolhido intencionalmente, por possuir um setor de proteção radiológica em funcionamento. Para o desenvolvimento da pesquisa, utilizou-se o método da triangulação de dados. Para tal, realizou-se o estudo em duas etapas, inicialmente realizou-se o estudo documental e observação não participante e, posteriormente entrevista semiestruturada, voltada para equipe multiprofissional atuante no serviço hospitalar de radiologia, ou seja, trabalhadores ocupacionalmente e para-ocupacionalmente expostos à radiação ionizante, que atuam no serviço. Na etapa da observação não participante, participaram 13 profissionais e na etapa da entrevista semiestruturada participaram 25, de um total de 46 profissionais que atuam no serviço. A amostra foi considerada suficiente quando ocorreu a saturação de dados. Foram observados e entrevistados os profissionais ativos na escala de trabalho do serviço e excluídos os trabalhadores afastados em situação de licença saúde ou maternidade. Para a análise dos dados utilizou-se a análise de conteúdo, pautada em Bardin, com auxílio de um software, o Atlas.ti 7.0 (Qualitative Research and Solutions). Os resultados encontrados a partir da observação não participante e da pesquisa documental subsidiaram a descrição detalhada de informações necessárias para que o cotidiano dos trabalhadores da saúde que atuam nos serviços de radiologia paute-se em ações quegarantam a proteção das pessoas que, por diferentes motivos, estão suscetíveis à exposição à radiação ionizante. Os resultados das entrevistas semiestruturadas foram discutidos em duas categorias principais: participação da equipe multiprofissional de saúde no PPR e implementação do PPR pela equipe multiprofissional de saúde, demonstrando que o PPR é um documento desconhecido de grande parte da equipe, o que indica que os trabalhadores teriam dificuldades em identificar intercorrências envolvendo radiações ionizantes e de encontrar rápidas soluções em situações emergenciais. Por fim, sugere-se uma maior frequência de supervisões e fiscalização, para que o PPR mantenha-se atualizado. A educação continuada também pode assegurar a qualidade dos Programas desenvolvidos no âmbito da proteção radiológica, contribuindo consequentemente, para garantia da organização dos setores de proteção radiológica, além de garantir a integridade da saúde dos que atuam em ambientes com emissores de radiação ionizante.<br> / Abstract : Qualitative study, exploratory and descriptive based on data from non-participant observation, semi-structured interviews and documentary analysis: Description of Memorial, which contains the Radiation Protection Program (RPP) of the radiology department of a public teaching hospital in southern Brazil and current legislation in Brazil about the PPR and radiological protection. Aimed to analyze the implementation and the knowledge of the multidisciplinary health team about PPR in a hospital radiology service. The specific objectives were to compare the PPR hospital radiology service with the provisions of law; Identify the participation of multidisciplinary health team in PPR and describe the implementation of the PPR by the multidisciplinary team. The hospital was intentionally chosen, by owning a radiological protection sector in operation. For the development of the research, we used the method of data triangulation. To this end, we carried out the study in two stages, initially held the desk study and non-participant observation and later semi-structured interviews, focused on multidisciplinary team operating in the hospital radiology department, in other words, occupationally and paraoccupationally exposed workers to ionizing radiation, which act in the service. In the stage of non-participant observation, attended by 13 professionals and semi-structured interviews step attended 25 out of a total of 46 professionals working in the service. The sample was considered sufficient when it occurred to data saturation. Were interviewed and observed professionals active in the working range of service and excluded workers away on leave or maternity health situation. For data analysis we used the content analysis, guided by Bardin, with the help of a software, the Atlas.ti 7.0 (Qualitative Research and Solutions). The results from the non-participant observation and document research supported the detailed description of information necessary for the daily life of health workers who work in radiology services whose agenda on actions to ensure the protection of persons who, for different reasons are susceptible to exposure to ionizing radiation. The results of the semi-structured interviews were discussed in two main categories:participation of the multidisciplinary health care team in PPR and implementation of the multidisciplinary health care team, demonstrating that PPR is an unknown document of much of the staff, which indicates that workers would have difficulty identifying complications involving ionizing radiation and to find quick solutions in emergency situations. Finally, it is suggested a higher frequency of supervision and inspection, so that the PPR keep up to date. Lifelong learning can also ensure the quality of their programs in the context of radiological protection, contributing thus to guarantee the organization of radiological protection sectors, and ensure the integrity of health who work in environments with ionizing radiation emitters.
328

Síndrome pulmonar por hantavírus : aspectos epidemiologícos e clínicos de 18 casos do Estado do Rio Grande do Sul

Severo, Marilia Maria dos Santos January 2002 (has links)
A infecção por Hantavirus pode causar febre hemorrágica com doença renal ou doença respiratória grave. Em novembro de 1998 foi diagnosticado o primeiro caso de Síndrome Pulmonar por Hantavirus (SPH) no Rio Grande do Sul (RS), Brasil. O objetivo deste estudo foi analisar os dados epidemiológicos, as características clínicas e a evolução dos casos de infecção por Hantavirus no RS. Foram estudados os dados dos primeiros 18 casos de SPH no RS, confirmada pela pesquisa de IgM para o vírus Sin Nombre pelo método de Ensaio Imuno Enzimático (ELISA), diagnosticados entre 01 de novembro de 1998 e 31 de dezembro de 2000. A média de idade dos pacientes foi de 39,8 anos (variando de 21 a 65 anos), 17 eram homens, 13 pacientes eram agricultores. As principais atividades de risco identificadas foram colheita e armazenamento de grãos (82,4%) e contato com roedores (76,5%). Os sintomas mais freqüentes foram febre (100%), mialgias (88,9%), dispnéia (88,9%), tosse seca (83,3%), dor abdominal (77,8%), vômitos (72,2%) e cefaléia (66,7%). Os achados mais comuns ao exame físico foram taquicardia (87,6%), hipotensao (72,2%), cianose (66,6%), agitação (55,6%) e edema periférico (38,9%). Treze pacientes (72,2%) apresentaram eventos hemorrágicos como hematúria (44,4%), hemoptise (27,7%) ou hematêmese (11,1%). Dois pacientes apresentaram insuficiência renal aguda grave. As anormalidades laboratoriais incluíram leucocitose (77,8%, média de 16,4 x 103 por mm3), freqüentemente com formas jovens, aumento de hematócrito (em 61,1% dos pacientes, média de 52,4%), trombocitopenia (em 9 de 12 casos, média de 91,4x 103 por mm3) e creatinina sérica aumentada (em 13 de 15 pacientes). A radiografia de tórax, realizada em 17 pacientes, mostrou infiltrado intersticial em 94,1%, padrão alveolar em 58,8% e derrame pleural em 76,5% dos casos. Sete pacientes, todos com insuficiência respiratória grave, foram a óbito (taxa de mortalidade de 38,9%). O número médio de dias do início dos sintomas até o óbito foi 7,3 (variando de 4 a 9). Concluímos que, nos nossos casos, a Hantavirose acometeu especialmente homens, em faixa etária produtiva, e que a zona rural foi o provável local de contaminação dos pacientes. Adicionalmente, a SPH caracterizou-se por um quadro febril agudo com queixas sistêmicas e respiratórias, podendo apresentar manifestações hemorrágicas e, infreqüentemente, insuficiência renal. Casos graves evoluíram com edema pulmonar, rapidamente progressivo. A letalidade relacionada à doença foi elevada. / Hantavirus can cause hemorrhagic fever and renal disease or severe respiratory illness. In November 1998 the first case of Hantavirus Pulmonary Syndrome (HPS) was identified in Rio Grande do Sul (RS), Brazil. The aim of this study was to analyze epidemiological, clinicai and laboratory data and outcome of Hantavirus infection in RS, confirmed by the detection of IgM antibodies for Sin Nombre Virus using an enzymelinked immunosorbent assay (ELISA). Epidemiological and clinicai findings of the first 18 HPS cases in RS, diagnosed between November 01,1998 and December 31, 2000 were studied. The mean age of the patients was 39.8 years (range, 21 to 65); 17 were male, and 13 were farmers. The main identified risk activities were harvesting or storage of grains (82.4%) and contact with rodents (76.5%). The most common symptoms were fever (100%), myalgias (88.9%), dyspnea (88.9%), dry cough (83.3%), abdominal pain (77.8%), vomiting (72.2%) and headache (66.7%). The most common physical findings were tachycardia (87.6%), hypotension (72.2%), cyanosis (66.6%), restlessness (55.6%) and peripherical edema (38.9%). Thirteen patients (72.2%) had hemorrhagic events as hematúria (44.4%), hemoptysis (27.7%) or hematemesis (11.1%). Two patients developed severe renal insufficiency. The laboratory abnormalities included leukocytosis (in 77,8% of the patients; mean cell count 16.4 x 103 per mm3), often with myeloid precursors, an increased hematocrit (in 56.0 percent of patients; mean 52.4%), thrombocytopenia (in 9 out of 12 cases; mean platelet count, 914 x 103 per mm3), an elevated serum creatinine concentration (in 13 of 15 patients). Chest radiography, carried out in 17 patients, showed interstitial infiltrates in 94.1%, alveolar pattern in 58.8% of the patients and pleural effusion in 76.5% of the cases. Seven patients, ali with severe respiratory failure, died (case fatality rate, 38.9% percent). The mean number of days from onset of symptoms to death was 7.3 (range, 4 to 9). We concluded, in our cases, that HPS occured mainiy men, in productive age and the rural área was the probable place of patients' contamination. Additionally, HPS is characterized by a febrile illness with systemic and respiratory complaints, can exhibit hemorrhagic disturbances and, uncommonly, renal failure. Rapidly progressive, pulmonary edema occured in severe disease. The case fatality rate ofthe disease was high.
329

Radiografia periapical digital: análise comparativa de doses de entrada e produto dose/área em órgãos da cabeça e pescoço

López, Guillermo Alberto January 2013 (has links)
Submitted by Barroso Patrícia (barroso.p2010@gmail.com) on 2014-08-10T01:24:18Z No. of bitstreams: 1 LÓPEZ, Guillermo Alberto.pdf: 3488692 bytes, checksum: 8afbe5ed66272012974c3fa088c075c4 (MD5) / Made available in DSpace on 2014-08-10T01:24:18Z (GMT). No. of bitstreams: 1 LÓPEZ, Guillermo Alberto.pdf: 3488692 bytes, checksum: 8afbe5ed66272012974c3fa088c075c4 (MD5) / A radiação é uma forma de energia, emitida por uma fonte e transmitida através do vácuo, do ar ou de meios materiais, sendo, portanto, uma energia em trânsito. No caso da radiação eletromagnética incidente em corpos no ar, parte da sua intensidade pode ser refletida na interface ar-pele e outra parte transmitida através do corpo. O objetivo deste estudo foi comparar as doses de radiação obtidas com três equipamentos radiológicos, dois da marca Kodak® 2200 Intraoral X-ray System de características similares e um da marca Dabi Atlante® Seletronic utilizados para radiografias periapicais digitais.Foram medidas as doses de entrada em órgãos e o produto dose-área utilizando-se um protótipo de crânio contendo osso seco e material equivalente a tecido humano. A dose de radiação para diferentes protocolos foi avaliada através do produto kerma-área, utilizando-se o equipamento fabricado pela IBA DOSIMETRY®, modelo KERMAX® plus DDP TinO. Para a medição das doses de entrada em órgãos foi utilizado um sensor de estado sólido marca Radcal® Accu-Gold® de radiodiagnóstico para medir as doses efetivas e comparar as indicadas no equipamento com as capturadas no sensor. Utilizando-se tensão de 60 kV e de 70 kV foram obtidos os seguintes resultados: a média da dose de radiação foi de 0,010 mGy nos cristalinos, 0,033 mGy nas glândulas parótidas, 0,388 mGy na glândula sublingual e 0,470 na tireoide; a dose de entrada na pele foi de 3,02 mGy (dentes incisivos) e de 4,20 mGy (dentes molares); o valor mínimo do PKA foi de 32,49 mGy.cm2, e o máximo, de 275,25 mGy.cm2. Os resultados obtidos foram comparados com os de outros estudos que utilizaram equipamentos intraorais e protocolos similares. Da análise dos resultados, concluiu-se pela importância da utilização de baixas doses de radiação e do adequado posicionamento do equipamento para a realização de incidências radiológicas de exames periapicais em região maxilar e mandibular, minimizandose possíveis efeitos biológicos sobre estruturas de órgãos radiossensíveis.
330

O profissional de enfermagem no serviço de hemodinâmica na perspectiva da ergonomia e proteção radiológica

Pereira, Aline Garcia January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia de Produção, Florianópolis, 2015. / Made available in DSpace on 2016-10-19T13:01:41Z (GMT). No. of bitstreams: 1 338952.pdf: 2285659 bytes, checksum: cc2c9de743c199f16aa70ed8a281379f (MD5) Previous issue date: 2015 / O serviço de hemodinâmica é uma modalidade da radiologia intervencionista, que possui como destaque os procedimentos de cateterismo e angioplastia, os quais requerem uma equipe multiprofissional que atua de forma multifuncional. Dentre esta, estão os profissionais da enfermagem, responsáveis pelos cuidados com o paciente, e estão expostos à radiação ionizante, assim como fatores ambientais e organizacionais do ambiente de trabalho. A proteção radiológica constitui-se como fator relevante para a saúde do trabalhador e do paciente, a partir do cumprimento de diretrizes, tais como: princípios da justificação, limitação de dose, otimização e prevenção de acidentes. No entanto, é necessário compreender a atividade de trabalho a ser analisada; para tanto, a ergonomia é uma aliada no estudo das relações homem-máquina-ambiente. Sendo assim, a presente pesquisa tem como objetivo analisar a atividade dos profissionais de enfermagem no serviço de hemodinâmica, e suas interações relacionadas à luz da ergonomia e da proteção radiológica. O procedimento metodológico da pesquisa constituiu-se de três principais fases, correspondente ao desenvolvimento de três artigos científicos. Na primeira fase (Artigo 1), foi realizada uma pesquisa bibliográfica referente à gestão na radiologia; a partir das constatações obtidas foi feito o levantamento do estado da arte especificamente do setor de radiologia intervencionista (Artigo 2), em seis bases de dados abordando os temas: radiologia intervencionista, enfermagem e ergonomia. Na terceira fase da pesquisa, foi realizado um estudo de caso (Artigo 3) a partir da metodologia de Análise Ergonômica do Trabalho com foco nas atividades da enfermagem, sendo o local de realização do estudo, uma clínica de Hemodinâmica de Florianópolis, SC. Como resultados pode-se observar que há falta de estudos sobre gestão na radiologia; além disso, dentre os principais problemas no setor estão: agenda, locomoção dos pacientes, localização dos materiais, peso dos aventais de chumbo, lombalgias, dores musculoesqueléticas, fadiga física e mental. Tais problemas ergonômicos destacam-se na literatura e foram constatados por meio do presente estudo de caso, interferindo nas questões organizacionais do setor e também no cumprimento dos princípios de proteção radiológica. Portanto, por meio da análise do sistema homem-máquina-ambiente da atividade de profissionais de enfermagem na hemodinâmica, pode-se concluir que a radiologia está em constante aperfeiçoamento, sendo que os problemas ergonômicos impactam na saúde e segurança dos profissionais de enfermagem, influenciando os princípios de proteção radiológica.<br> / Abstravt : Hemodynamic service is an interventional radiology modality, which highlight the procedures of catheterization and angioplasty, which require a multidisciplinary team that works on a multifunctional way. Among them are the nursing professionals, who are responsible for the care with the patient, and are exposed to ionizing radiation, as well as environmental and organizational factors of the working environment. The radiation protection constitutes a relevant factor for the health of the worker and the patient, from the compliance guidelines such as principles of justification, dose limitation, optimization and accident prevention. However, it is necessary to understand the analyzed work activity; therefore, ergonomics is an ally in the study of human-machine-environment relations. Thus, this research aims to analyze the nursing professionals? activity at hemodynamics service, and their interactions related to ergonomics and radiation protection. The methodological research procedure consisted of three main phases, corresponding to the development of three scientific articles. On the first step (Article 1), a literature research was conducted regarding the management in radiology; from the findings were made the research of state of art specifically on the interventional radiology sector (Article 2), in six different databases on the topics: interventional radiology, nursing and ergonomics. In the third was performed a case study (Article 3) with Ergonomic Analysis of Work metodology focused on nursing activities. The location of the study was in a catheterization clinic Florianópolis, SC. The results can show the lack of management studies in radiology; moreover, among the main problems in the sector are agenda, transportation of patients, location of materials, weight of lead aprons, back pain, musculoskeletal pain, physical and mental fatigue. Such ergonomic problems stand out in the literature and they were found through this case study, interfering in the sector's organizational matters and also in compliance with the radiation protection principles. Therefore, through the analysis of man-machine-environment system on nursing professionals at hemodynamics, it can conclude that radiology is in constantly improving, and the ergonomic problems influence the health and safety of nursing professionals, influencing radiation protection principles.

Page generated in 0.0406 seconds