• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 3
  • Tagged with
  • 8
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Repeterbarheten hos von Graefes metod för forimätning

Sandell, Louise January 2010 (has links)
<p>En vanlig undersökning som optiker använder för att mäta forier är von Graefes metod med kontinuerlig presentation.<strong></strong></p><p><strong>Syfte: </strong>Syftet med studien var att mäta repeterbarheten på denna metod för att kunna dra en slutsats angående hur optiker bör utföra mätningarna samt hur många mätningar som rimligtvis bör utföras för att ett pålitligt mätresultat ska fås. Syftet var även att kontrollera storleken på forierna samt refraktionens påverkan på repeterbarheten.</p><p><strong>Metod: </strong>Studien är baserad på 32 personer i åldrarna 19 till 32år. Undersökningen började med en anamnes, kontroll av samsyn samt en synundersökning. Efter det mättes horisontal- samt vertikalfori på sex meters håll respektive 0,4 meters håll. Varje fori mättes tre gånger för att repeterbarheten skulle kunna undersökas. Efter forimätningarna fick deltagarna svara på några frågor angående deras upplevelse av undersökningarna.</p><p><strong>Resultat: </strong>Det 95%-iga konfidensintervallet för horisontalforierna var ±1,86D respektive ±1,74D för avstånd respektive nära håll, samt ±0,12D  respektive ±0,18D för vertikalforierna. Olika personer visade däremot olika bra repeterbarhet. Korrelationen mellan horisontalfori, refraktion, repeterbarhet och vertikalfori var mycket dålig, då den låg mellan 0,08 och 0,45 för de olika faktorerna.</p><p><strong>Slutsats: </strong>För att få ett så exakt värde som möjligt på forierna bör minst tre mätningar utföras på vardera fori och ett medelvärde beräknas. Skillnaden mellan de olika mätningarna bör inte vara för stor då det påverkar medelvärdet i hög grad. Om detta är fallet bör ytterligare mätningar göras för att avgöra vilket värde som är missvisande.</p>
2

Repeterbarheten hos von Graefes metod för forimätning

Sandell, Louise January 2010 (has links)
En vanlig undersökning som optiker använder för att mäta forier är von Graefes metod med kontinuerlig presentation. Syfte: Syftet med studien var att mäta repeterbarheten på denna metod för att kunna dra en slutsats angående hur optiker bör utföra mätningarna samt hur många mätningar som rimligtvis bör utföras för att ett pålitligt mätresultat ska fås. Syftet var även att kontrollera storleken på forierna samt refraktionens påverkan på repeterbarheten. Metod: Studien är baserad på 32 personer i åldrarna 19 till 32år. Undersökningen började med en anamnes, kontroll av samsyn samt en synundersökning. Efter det mättes horisontal- samt vertikalfori på sex meters håll respektive 0,4 meters håll. Varje fori mättes tre gånger för att repeterbarheten skulle kunna undersökas. Efter forimätningarna fick deltagarna svara på några frågor angående deras upplevelse av undersökningarna. Resultat: Det 95%-iga konfidensintervallet för horisontalforierna var ±1,86D respektive ±1,74D för avstånd respektive nära håll, samt ±0,12D  respektive ±0,18D för vertikalforierna. Olika personer visade däremot olika bra repeterbarhet. Korrelationen mellan horisontalfori, refraktion, repeterbarhet och vertikalfori var mycket dålig, då den låg mellan 0,08 och 0,45 för de olika faktorerna. Slutsats: För att få ett så exakt värde som möjligt på forierna bör minst tre mätningar utföras på vardera fori och ett medelvärde beräknas. Skillnaden mellan de olika mätningarna bör inte vara för stor då det påverkar medelvärdet i hög grad. Om detta är fallet bör ytterligare mätningar göras för att avgöra vilket värde som är missvisande.
3

Framtagning av kalibreringsverktyg för referensmätningar : Vardaglig kontroll av kalibrering i industriell provbänk för pneumatiskt styrda tågbromsar

Ali, Mazin, Shahin, Mahdi January 2019 (has links)
Faiveley Transport Nordic AB is a company in Landskrona and which is an international supplier in the railway industry. The industry sight in landskrona is mostly focused on developing and manufacturing train brakes.Today, Faiveley has a number of test benches that needs regular checks and re-calibration every three months. In the current situation, it is the responsibility of the lab engineer to check that the calibration is correct on the test benches and adjust if needed. The purpose of this research is to design a reference object that will be used for checking the calibration on a test bench.During the research, the product development process was used with some tools from the design thinking process. The research begins with a lot of theoretical background about BFC (Brake Friction Concept), test benches and calibration to develop a deeper understanding for the different concepts.Since Faiveley had already identified the problem, the method was started directly by looking for other solutions that could inspire the solution to the problem. The search for inspiration was conducted through various methods such as patent searching, trend watching and techwatching. The authors proceeded by choosing the best possible ideas for them to create a prototype of the best concepts.After creating a prototype of the reference object, the objects function was verified by testing on a test bench to check if it meets the preset requirements. The authors were able to get the result for each one of them three measurement parameters such as force, distance and pressure. Results showed that most of the requirements was accomplished.Based on the results several conclusions could be drawn. Such as that the reference object that was the solution to the problem worked and partly fulfills the associated requirements. Through this research a method has been created for how to generate reference values for similar parameters in general contexts, which others interested can use in the future.
4

Fixationsdisparitet : En jämförelse av tre olika tester

Finnström, Caroline January 2017 (has links)
Syfte: Syftet med studien var att jämföra tre olika metoder (Mallettenheten, Saladinkortet och Wessonkortet) för att mäta fixationsdisparitet, se ifall metoderna hade en bra repeterbarhet samt jämföra resultaten från fixationsdisparitetstesterna med den uppmätta forin.Material och metod: I studien deltog 19 personer mellan 20–31 år, alla hade samsyn. Undersökningen utfördes i en ordning som gjorde att ögonen skulle tröttas ut så lite som möjligt för att inte påverka resultatet. Den började med anamnes, refraktion, forimätningar med modifierad Thorington på avstånd och på nära håll och sedan utfördes mätningar av fixationsdisparitet, varje metod utfördes tre gånger för att få fram ett medelvärde. Undersökningen avslutades med mätning av KNP, ackommodationsamplitud och vergensmätningar.Resultat: 11 av 19 försökspersoner hade någon fixationsdisparitet (FD) enligt Mallett, Saladin eller Wesson. Då Mallett endast mäter den associerade forin och inte FD så användes inte den i jämförelserna. Studien visar en statistiskt signifikant skillnad i uppmätt FD mellan Wesson och Saladin (p = 0,027). En Bland-Altman analys visade att skillnaden mellan mätresultaten blev högre ju högre fixationsdispariteten var. Repeterbarheten var god för Wesson (ICC = 0,95) och Mallett (ICC = 0,87), men något lägre för Saladin (ICC = 0,71). En envägs- RM ANOVA visade inga signifikanta skillnader mellan de tre mätningarna för någon av metoderna. 47 % av försökspersonerna hade en FD som gick åt samma håll som den uppmätta forin. 10 % hade FD som gick åt motsatt håll från forin. Varken Wesson eller Saladin visade någon signifikant korrelation med forin: Wesson (p = 0,11, R = 0,15) och Saladin (p = 0,08, R = 0,17).Slutsats: Studien visar att det fanns en signifikant skillnad mellan Saladintestet och Wessontestet och att de således inte är utbytbara med varandra. Repeterbarheten har varit god för två av tre metoder. Det här studien har visat att om fixationsdispariteten ska mätas kliniskt kan det vara bra för undersökaren att bestämma sig för ett test och bara använda det, det går inte att dra slutsatsen helt då detta bör testas på en större grupp försökspersoner. / The aim of this study was to compare three clinical tests used for measuring fixation disparity. The correlation between fixation disparity and phoria was evaluated and the repeatability for each method.This study included 19 subjects (aged from 20 to 31 years); all had functional binocular vision. The order of the tests in the examination was chosen to prevent fatigue from effecting the results. Following case history, binocular refraction, and phoria measurements at distance and near, the examination proceeded in measurement of fixation disparity with each of the three tests; three measurements were performed for each, and averaged. The examination concluded with measurements of NPC, amplitude of accommodation and vergences.Eleven of 19 subjects had FD to some degree according to Mallett, Saladin or Wesson. Since the Mallett unit only measures the associated phoria, the results could not be used in this study.This study shows a significant difference in measured FD between Wesson and Saladin (p=0.027). A Bland-Altman analysis showed a significant difference between the results; it showed that the higher the fixation disparity the greater the difference between the two measurements (p &lt;0.0001). The repeatability was good for Wesson (ICC = 0.95) and Mallett (ICC = 0.87), however lower for Saladin (ICC = 0.71). A One Way- RM ANOVA showed no significant difference between the three measurements for each method. FD deviated in the same direction as the measured phoria for 47 % of the subjects; 10 % had FD that deviated in the opposite direction from the measured phoria. Wesson and Saladin showed no significant correlation to the phoria: Wesson (Pearsson r = 0.15; p = 0.11), and Saladin (Pearsson r = 0.17; p= 0.08).The study shows that there is a significant difference in the results of fixation disparity between the Saladin card and the Wesson card indicating that these methods can’t be used interchangeably. Repeatability was better for Mallett and Wesson but not so good for Saladin. There was a significant correlation between phoria and fixation disparity in means of the direction of deviation i.e. an exophoria is often followed by an exo fixation disparity.In a clinical setting, it might be advisable to adopt one single method and not compare results with those obtained by other instruments.
5

Accuracy and Repeatability of a Robotic Arm / Noggrannhet och repeterbarhet för en Robotarm

Lidholm, Carl-Victor, Runnquist, Victor January 2021 (has links)
The purpose of this project was to create a model of a robotic arm with 4-DOF equipped with a gripper that is able to move an object to a predetermined area. This thesis investigated the robotic arm’s accuracy by repeating the same predetermined movement and measure the error. The error was measured based on the objects displacement from the target area after a series of repeated movements by the arm. After constructing the robotic arm, an experiment was set up to measure the accuracy and repeatability of the arm. The robot achieved 2.506 mm to 0.922 mm for accuracy and 5.995 mm to 4.059 mm for repeatability depending on speed. / Syftet med detta projekt var att skapa en modell av en robotarm med 4 frihetsgrader och en klo för att kunna flytta ett objekt till ett förbestämt område. Denna avhandling har undersökt robotens noggrannhet genom att upprepa enförbestämd rörelse och mäta felet. Felet bestämdes genomatt flytta ett objekt till en förbestämd plats och mäta objektets position i förhållande till målet. Den färdigkonstruerade roboten har en noggrannhet på 2.506 mm till 0.922 mm och en repeterbarhet på 5.995 mmtill 4.059 mm beroende på hur fort roboten rör sig.
6

Repeatability of Additive Manufactured Parts

Tollander, Sofia, Kouach, Mona January 2017 (has links)
Saab Surveillance in Järfä̈lla constructs complex products, such as radars and electronic support measures. Saab sees an advantage in manufacturing details with additive manufacturing as it enables a high level of complexity. Additive manufacturing is relatively new in the industry and consequently there are uncertainties regarding the process. The purpose of this bachelor thesis was to improve the knowledge of the repeatability of additive manufactured parts as well as compare additive manufactured test rods in two different directions, horizontally and vertically, to subtractive manufactured test rods with a vibration test. The vibration test was conducted to simulate the operative environment where the additive manufactured parts might be implemented in the future. Before the vibration test could be performed, the test rods were designed in a 3D-modeling program and analysed with a finite element method to achieve the required natural frequency range of 100 - 200 Hz and a maximal bending stress of 60 - 80 MPa in the notched area of the test rod. It was concluded that the subtractive manufactured test rods had the highest repeatability. The horizontally additive manufactured test rods had a higher repeatability than the vertically additive manufactured test rods, but the vertically additive manufactured test rods had the highest overall strength. It was also concluded that more studies are needed to ensure that additive manufactured parts can be produced with high repeatability while maintaining the structural integrity. / Saab Surveillance i Järfä̈lla konstruerar komplexa försvarsprodukter som till exempel radarsystem. Additiv tillverkning i metall möjliggör tillverkning av produkter med hög komplexitet, men då tillverkningsprocessen är relativt ny i industrin finns det en stor osäkerhet kring processen. Syftet med detta kandidatexamensarbete var att få en bättre förståelse för repeterbarheten hos additivt tillverkade delar samt att jämföra additivt tillverkade provstavar konstruerade i två olika riktningar, horisontellt och vertikalt, med svarvade provstavar med hjälp av ett vibrationstest. Vibrationstestet genomfördes för att simulera den operativa miljön där de additivt tillverkade detaljerna skulle kunna implementeras i framtiden. Innan vibrationstestet kunde utföras simulerades provstavarnas design i en mjukvara för 3D-modellering. En finit element-analys utfördes även fö̈r att få en egenfrekvens inom intervallet 100 - 200 Hz och en maximal böjspänning mellan 60 - 80 MPa i anvisningen på provstaven. Slutsatsen drogs att de traditionellt bearbetade stavarna hade den högsta repeterbarheten. De horisontellt additivt tillverkade stavarna hade högre repeterbarhet än de vertikalt additivt tillverkade stavarna, men att de vertikalt additivt tillverkade stavarna hade ett längre utmattningsliv. Det kunde även konstateras att fler studier inom ämnet behövs för att kunna säkerställa repeterbarheten hos additivt tillverkade delar utan att behöva kompromissa med hållfastheten.
7

Identification of Potential Sources of Measurement Errors in an Isokinetic Dynamometer : Reliability Analysis of Shoulder Abduction and Flexion Data / Identifiering av potentiella källor till mätfel hos en isokinetisk dynamometer : Tillförlitlighetsanalys av axelabduktion och flexionsdata

Grannerud, Malena January 2022 (has links)
The evaluation of shoulder abduction and flexion strength is important in the rehabilitation after rotator cuff tear. The purpose of this work is to assess the intra and inter-rater reliability of measurement data from an isokinetic dynamometer used to evaluate shoulder abduction and flexion strength, with the aim to identify sources of measurement errors and suggest improvements. The measurement data was collected by a research group at Karolinska Institute and contained load and torque data from thirteen healthy subjects in the ages of 25 to 87 years. The measurements were carried out on two occasions, one week apart. Systematic differences between occasions are analyzed using the Shapiro Wilk test, the paired t-test, and Wilcoxon signed rank test. The agreement of the measurements is analyzed quantitatively using the coefficient of variation and the Bland Altman plot, and quantitively, using the intraclass correlation coefficient. A significant systematic difference in shoulder abduction and flexion load measurements was found, and the recommendation to prevent this is that components should be calibrated in a standardized way. The measurements showed varying reliability within and between measurement occasions and that after familiarization with the isokinetic dynamometer, repeatability improved. The findings indicate a need of a standardized protocol for patient education and placement. Measurements from the position sensor contributed to more random torque values. To improve the repeatability in measurements from the position sensor, axis of rotation should be kept aligned. An increasing variability in measurements with increasing load and torque was found. The recommendation is to use a preload for patients using more force in the movement, to make sure a preset speed is not exceeded, which contributes to more reliable measurements. / Utvärderingen av axelabduktion och flexionsstyrka är viktig i rehabiliteringen efter skada i axelleden. Syftet med det här arbetet är att bedöma intra- och interbedömartillförlitligheten hos mätdata från en isokinetisk dynamometer som används för att utvärdera axelabduktion och flexionsstyrka, med syftet att identifiera källor till mätfel och föreslå förbättringar. Mätdatat samlades in av en forskargrupp vid Karolinska Institutet och innehöll belastnings- och vridmomentdata från tretton friska försökspersoner i åldrarna 25 till 87 år. Mätningarna utfördes vid två tillfällen med en veckas mellanrum. Systematiska skillnader mellan tillfällena analyseras med Shapiro Wilk-testet, det parade t-testet och Wilcoxon signed rank test. Mätningarnas överensstämmelse analyseras kvantitativt med hjälp av variationskoefficienten och Bland Altman-diagrammet, samt kvalitativt med hjälp av intraklasskorrelationskoefficienten. En signifikant systematisk skillnad i axelabduktion och flexionsbelastningsmätningar hittades, och rekommendationen för att förhindra detta är att komponenter bör kalibreras på ett standardiserat sätt. Mätningarna visade på en varierande tillförlitlighet inom och mellan mättillfällen och att efter bekantskap med den isokinetiska dynamometern, förbättrades repeterbarheten. Slutsatserna indikerar ett behov av ett standardiserat protokoll för patientutbildning och placering. Mätningar från positionssensorn bidrog till mer slumpmässiga vridmomentvärden. För att förbättra repeterbarheten i mätningar från positionssensorn bör rotationsaxeln hållas i linje. En ökande variation mellan mättillfällen med ökande belastning och vridmoment hittades. Rekommendationen är att använda en förspänning för patienter som använder mer kraft i rörelsen, för att säkerställa att en förinställd hastighet inte överskrids, vilket bidrar till mer tillförlitliga mätningar.
8

Vad är god praxis för kalibrering och funktionskontroller av vågar inom läkemedelsindustrin / What is the best practice for calibration and routine testing of balances in the pharmaceutical industry

Gourie, Roberto January 2022 (has links)
I denna studie så ville AstraZenecas dispenseringsfunktion, som arbetar med att finfördelamaterial från sin bulkförpackning undersöka hur och med vilka frekvenser kalibreringar ochfunktionskontroller för deras vågar bör göras. Detta i hopp om att harmonisera en uppdateradoch förbättrad standard mellan siterna Gärtuna och Snäckviken. Standarder inom mätningslära är inget som läkemedelsföretag själva investerar resurser i, utanföljer det som farmakopéerna världen över publicerar i sina böcker. Däri återfinns allt som kantänkas behövas för tillverkning och utformning av läkemedel. Syftet med att kalibrera ochgenomföra funktionskontroller så ofta som AstraZeneca gör i dagsläget är för att vara förenligamed regelverk för att bli godkända vid inspektioner. Däremot finns risken attfunktionskontroller och kalibreringar genomförs med högre eller lägre frekvens än vad de bordegöras samt att irrelevanta tester vid dessa kontroller får alltför hög prioritering för att påvisa envågs förmåga att fungera som den ska. För att undersöka detta genomfördes det en kartläggning av hur AstraZeneca arbetar idag medvågkalibreringar och funktionskontroller. Denna behandlade både hur arbetet sker internt viaegna funktioner, men också externt via vågtillverkaren och valideringsfirmor. Dennainformation tillsammans med vad farmakopéerna och vågtillverkaren själva påstår är korrektarbetssätt blev ett tydligt och effektivt sätt att sålla bort överflödiga och i vissa fall irrelevantametoder som används på AstraZeneca idag. Utöver dessa finns det fenomen såsommätosäkerhet och störningselement som kan påverka varje vägning till den grad där resultatenär fullständigt missvisande, och i läkemedelsindustrins fall är dessa oacceptabla. Vid studiens slut kunde flera systematiska brister identifieras och rekommendationer för attmotverka eller lösa dessa gavs i enlighet med syftet om att nå god praxis för våganvändningen isamband med dispenseringsprocessen. Framtida förbättringsarbeten hade förenklats ocheffektiviserats till stor del om en fullständig digitalisering och övervakning avstörningselementen möjliggörs. / In this study that was commissioned by AstraZeneca's dispensing function that worksmainly by sub-dividing materials from its bulk packaging. They wanted to investigatehow and with what frequencies calibrations and routine testing for their balances shouldbe performed. This, with the purpose of harmonizing an updated and improvedstandard between the sites Gärtuna and Snäckviken. Measurement theory standards are not something that pharmaceutical companiesthemselves invest resources in but rather follow what pharmacopoeias around the worldpublish in their books. The books contain everything that may be needed for themanufacturing and design of medicines. The purpose of calibrating and performingroutine testing as often as AstraZeneca does today is to comply with regulations to beapproved during inspections. However, there is a risk that routine testing andcalibrations are performed at a higher or lower frequency than they should be, and thatirrelevant tests at these routine tests are given too high a priority to demonstrate abalances ability to function properly. To investigate this, a survey was conducted of how AstraZeneca works today withbalance calibrations and routine testing. The survey considered both how the work isdone internally via AstraZeneca’s own employees, but also externally via the balancemanufacturer and validation companies. This information, in combination with whatthe pharmacopoeias and the balance manufacturer themselves claim is the correct wayof operating, became a clear and effective way of sifting away superfluous and in somecases irrelevant methods used in AstraZeneca today. In addition to these, there arephenomena such as measurement uncertainty and external disturbance elements thatcan affect any weighing to the extent that the results are completely misleading, and inthe case of the pharmaceutical industry, such results would be unacceptable. At the end of the study, several systematic flaws or shortcomings could be identified andrecommendations to counteract or solve these were given in accordance with the aim ofachieving best practice for the use of balances in connection with the dispensingprocess. Future improvement work would have been greatly simplified and streamlinedif complete digitization and monitoring of the disturbance elements were made possible.

Page generated in 0.0513 seconds