• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 127
  • 82
  • 12
  • 10
  • 9
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 288
  • 97
  • 94
  • 74
  • 49
  • 43
  • 41
  • 40
  • 39
  • 37
  • 36
  • 29
  • 28
  • 28
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Contribuição da imagem tridimensional para o diagnóstico do cisto de retenção mucoso do seio maxilar / Three-dimensional Image Contributing to the diagnosis of Mucous Retention cyst in Maxillary Sinus

RODRIGUES, Cleomar Donizeth 31 May 2011 (has links)
Made available in DSpace on 2014-07-29T15:25:17Z (GMT). No. of bitstreams: 1 TESE CLEOMAR D RODRIGUES -Cisto Ret Mucoso Seio Maxilar.pdf: 1752210 bytes, checksum: 164b291567764c89587221e7d462d819 (MD5) Previous issue date: 2011-05-31 / Objective: To detect the mucous retention cyst of maxillary sinus (MRCMS) through panoramic radiography and cone beam computed tomography (CBCT). Methods: Six thousand panoramic radiographs were selected from digital database for diagnostic analysis of MRCMS. We detected suggestive images of MRCMS in 185 radiographs of patients who were located and invited to return to control. Thirty patients returned for the realization of panoramic radiography for control between 6 and 46 months. Given the presence of MRCMS by radiographic control we performed the CBCT for a better evaluation of the maxillary sinus. Cysts were measured and compared through the images of two methods. The Wilcoxon, Spearman and Kolmorogov-Smirnov tests were used for statistical analysis. The level of significance was set at 5%. Results: There was statistically significant difference between the methods for detection of MRCMS (p <0.05); 23 MRCMS detected by panoramic radiography control were confirmed by CBCT, however, 5 MRCMS detected in CBCT images were not identified by panoramic radiographs. Eight MRCMS detected by X-ray control were not confirmed by CBCT. The discrepancy of extent of MRCMS between images of initial panoramic radiographs and control ones for the CBCT were not statistically significant (p = 0.617 and p = 0.626, respectively) as well as the correlation between time and discrepancy of extent of MRCMS (r = -0.16, p = 0.381). Conclusion: The cone beam computed tomography examination provides more accurate detection of MRCMS than panoramic radiography / Objetivos: Detectar o cisto de retenção mucoso do seio maxilar (CRMSM) por meio da radiografia panorâmica e tomografia computadorizada de feixe cônico (TCFC). Metodologia: Seis mil radiografias panorâmicas foram selecionadas do banco digital de dados para análise de diagnóstico de CRMSM. Foram detectadas imagens sugestivas de CRMSM em 185 radiografias, cujos pacientes foram localizados e convidados a retornar para controle. Trinta indivíduos retornaram para a realização de radiografia panorâmica para controle entre 6 e 46 meses. Constatada a presença do CRMSM pelo controle radiográfico realizava-se a TCFC, para uma melhor avaliação do seio maxilar. Cistos foram mensurados e comparados por meio das imagens dos dois métodos. Os testes de Wilcoxon, de Spearman e Kolmorogov-Smirnov foram utilizados para análise estatística. O Nível de significância estabelecido foi de 5%. Resultados: Foi observada diferença estatisticamente significante entre os métodos para detecção dos CRMSM (p<0,05); 23 CRMSM diagnosticados por meio da radiografia panorâmica controle foram confirmados por TCFC, no entanto, 5 CRMSM detectados em TCFC não foram identificados pelas imagens de radiografias panorâmicas. Oito CRMSM detectados pelo controle radiográfico não foram confirmados pela TCFC. A discrepância da extensão do CRMSM entre as imagens das radiografias panorâmicas inicial e controle e da panorâmica controle e TCFC não foram estatisticamente significantes (p=0,617 e p=0,626, respectivamente), bem como a correlação entre tempo e a discrepância da extensão dos CRMSM (r= -0,16 e p= 0,381). Conclusão: O exame por tomografia computadorizada do feixe cônico apresentou maior potencial de detecção de CRMSM que a radiografia panorâmica.
212

Alterações estruturais da face e dos seios paranasais avaliados por tomografia computadorizada multislice em pacientes com leishmaniose mucosa tratada / Facial structure alterations and abnormalities of the paranasal sinuses on multidetector computed tomography scans of patients with treated mucosal leishmaniasis

Raphael Abegão de Camargo 10 February 2014 (has links)
Introdução: No Brasil, a leishmaniose tegumentar americana (LTA) é uma importante antropozoonose endêmica na maioria das regiões do país. Apesar da expansão da doença nos últimos anos, a LTA continua a ser uma doença negligenciada. A leishmaniose mucosa (LM) tem como principal agente causador a Leishmania (V.) brasilienses, e habitualmente ocorre meses ou anos após a infecção cutânea sintomática ou assintomática. Aproximadamente 5% dos pacientes com leishmaniose cutânea não tratada adequadamente irão desenvolver a LM, forma que causa importante morbidade aos pacientes. A LM é uma doença progressiva, que acomete cartilagens e estruturas ósseas da face, faringe e laringe. Complicações associadas à leishmaniose mucosa já foram descritas, embora não existam estudos que avaliem as alterações estruturais da face e seios paranasais utilizando métodos radiológicos e que estimem a prevalência de sinusopatia nesta população ou que a compare com a população geral. Objetivo: Avaliar o grau de opacificação dos seios paranasais em pacientes com leishmaniose mucosa tratada, assim como eventuais alterações anatômicas na face associadas à LM, através de tomografia computadorizada multislice (TCM) dos seios paranasais e comparar os achados encontrados nesta população com um grupo controle formado por pacientes que realizaram TCM de órbita. Este estudo também tem o escopo de determinar a prevalência de sinusopatia crônica nos pacientes com LM pós-tratamento, bem como encontrar prováveis variáveis preditoras que possam estar relacionadas com a gravidade da sinusopatia e das alterações tomográficas encontradas. Métodos: Foram avaliados 54 pacientes com LM tratada, que foram submetidos à TCM dos seios da face, e comparados com grupo controle de 40 pacientes que realizaram TCM de órbita. A análise das tomografias foi realizada a partir de reconstruções multiplanares nos planos axial, coronal e sagital. Foram avaliados o grau de opacificação (sinusopatia) dos seios paranasais, bem como a existência de eventuais alterações na face que pudessem estar relacionadas à LM. O grau de sinusopatia foi estabelecido seguindo-se os critérios de Lund-Mackay, segundo os quais foram atribuídos um valor para o grau de opacificação de cada sistema sinusal e dos complexos ostiomeatais, comparando o score dos casos com o dos controles. Posteriormente foi realizada uma análise comparativa entre os pacientes do grupo leishmaniose mucosa, que foram divididos em dois subgrupos, de acordo com a presença (Lund-Mackay >= 4) ou ausência (Lund-Mackay < 4) de doença sinusal, sendo 40 e 14 pacientes respectivamente. Após esta divisão foram feitas análises univariadas exploratórias em busca de variáveis preditoras que pudessem estar associadas com uma maior gravidade de sinusopatia apresentada. O nível de significância foi estabelecido com p<0,05. Resultados: Quarenta dos 54 pacientes com antecedente de LM (74,1%) apresentaram score tomográfico compatível com sinusopatia crônica (Lund-Mackay >= 4). Os pacientes do grupo leishmaniose mucosa apresentaram maior score de Lund-Mackay que os pacientes do grupo controle, bem como maior número de alterações na TCM dos seios paranasais, provavelmente associadas à leishmaniose. Estes pacientes também apresentaram graus mais severos de opacificação parcial e espessamento mucoso pansinusal 23/54 (42.6%). Além disso, opacificação total de pelo menos um dos seios paranasais só foi observada nos pacientes do grupo leishmaniose mucosa. Os pacientes com leishmaniose com score de Lund-Mackay >= 4 apresentaram maior tempo de sintomas até o primeiro tratamento e doença mais grave no momento do diagnóstico, sendo portanto prováveis variáveis preditoras de gravidade da sinusopatia. Conclusão: As tomografias computadorizadas dos seios paranasais dos pacientes com LM apresentaram diversas alterações estruturais, demonstrando o poder destrutivo desta doença. A alta prevalência de sinusite crônica observada nas tomografias computadorizadas desses pacientes quando comparados ao grupo controle, sugere que a LM pode ser um fator de risco para o desenvolvimento de sinusite crônica nesta população. Sexo masculino, tempo de sintomas até o primeiro tratamento e gravidade da LM no momento do diagnóstico podem ser consideradas prováveis variáveis preditoras de sinusite crônica nesses pacientes / Introduction: American tegumentary leishmaniasis (ATL) is an important anthropozoonosis that is endemic in most regions in Brazil. Despite the spread of the disease in recent years, ATL remains a neglected disease. Mucosal leishmaniasis (ML) is mainly caused by Leishmania (V.) brasiliensis agent, and usually occurs months or years after symptomatic or asymptomatic skin infection. Approximately 5% of patients with untreated cutaneous leishmaniasis will develop ML, a presentation that causes significant morbidity to patients. The mucosal leishmaniasis is a progressive disease that affects cartilage and bone structures of the nose and paranasal sinuses as well as other upper respiratory tract structures. Complications associated with ML have been described, but there is a lack of studies which evaluate the structural changes of the nose and paranasal sinuses in ML using radiological methods. Objective: To assess the degree of opacification of the paranasal sinuses in patients with treated mucosal leishmaniasis as well as any anatomic changes in the face associated with ML through multidector computed tomography scans (MDCT) of the sinuses, and compare the findings in this population with a control group. This study also aims at determining the prevalence of chronic sinusitis in patients with treated ML as well as finding probable predictive variables that may be related to the severity of sinus disease and CT findings. Methods: We evaluated 54 patients with treated ML who were submitted to MDCT of the sinuses, and compared with a control group of 40 patients who underwent MDCT of orbit. Analysis of the scans was performed from multiplanar reconstructions in the axial, coronal and sagittal views. The degree of sinus disease was assessed according to the Lund-Mackay criteria, in which a value was assigned to the degree of opacification of each sinus system and ostiomeatal complexes, and the scores from the mucosal leishmaniasis group were compared to the control group. A comparative analysis was then performed among patients in the mucosal leishmaniasis group, who were divided into 2 subgroups according to the presence (Lund-Mackay >= 4) or absence (Lund-Mackay < 4) of sinus disease, with 40 and 14 patients respectively. Following this subdivision, exploratory univariate analysis were performed to identify predictive variables that could be associated to the presentation of greater severity of sinus disease. The level of significance was defined as p <0.05. Results: Forty of the 54 patients with a history of ML (74.1%) had a tomographic score compatible with chronic sinusitis (Lund- Mackay >= 4). CT scans in the leishmaniasis and control groups demonstrated significant differences in terms of facial structural alterations. Patients from the mucosal leishmaniasis group showed more severe levels of partial opacification and pan sinus mucosal thickening 23/54 (42.6%), furthermore complete opacification of at least one paranasal sinus was only observed in the leismaniasis group. Patients from the mucosal leishmaniasis group with Lund-Mackay score >= 4 presented greater length of symptoms before treatment and more severe presentation of the disease at the diagnosis. Conclusion: CT scans of the sinus of patients with ML also presented several structural alterations, expressing the prominent destructive feature of the disease. The higher prevalence of chronic rhinosinusitis observed in CT scans of patients with treated ML in this study when compared to the control group suggests that ML can be seen as a risk factor for chronic rhinosinusitis in this population. Male sex, having the disease for more than two years before first treatment and/or a more severe presentation of ML at diagnosis, can be considered as predictive variables of chronic sinusitis in these patients
213

Influência da associação de osso bovino mineral com osso alógeno fresco congelado em enxertos para levantamento de seio maxilar. Estudo clínico, histológico e histomorfométrico em humanos / Bovine bone mineral combined with fresh frozen allografts bone in sinus augmentation. Case series, histological and histomorphometrical in humans.

Sehn, Felipe Perraro 30 May 2014 (has links)
O osso alógeno fresco congelado e o Bio-Oss® (OBM) são materiais conhecidos como substitutos ao osso autógeno em cirurgias de levantamento de seio maxilar. O objetivo deste estudo foi avaliar clínica, histológica e histomorfometricamente o processo de reparo de enxertos alógenos com e sem a utilização de OBM, utilizados em técnicas de levantamento de seio maxilar em humanos. Neste estudo do tipo prospectivo, randomizado, tipo série de casos, comparativo, foram operados 34 seios maxilares de pacientes de ambos os sexos, que apresentavam um rebordo ósseo residual com altura máxima de 5 mm na região de seios maxilares para reconstrução em altura para cirurgias de levantamento de seio maxilar prévia à reabilitação por implantes. Os pacientes foram divididos em a) Grupo Controle: Dezessete (17) seios maxilares enxertados somente com a utilização de osso alógeno e b) Grupo Teste: 17 seios maxilares reabilitados com osso alógeno e OBM, na proporção de 2:1. Seis meses após a enxertia, no momento da instalação dos implantes, amostras ósseas foram coletadas por meio de trefinas para análise histológica e histomorfométrica. Os dados da investigação foram submetidos ao teste t de Student para amostras independentes empregado para comparações entre os dois grupos, Mann-Whitney e testes de correlação foram aplicados. 29 pacientes com uma média de idade de 51,32 anos (± 6,44), foram divididos em grupos controle (17) e teste (12), sendo 34 seios avaliados no total. Não houve diferença estatística entre os grupos com relação à idade (p = 0,23) e ao gênero (p = 0,56). Mediana do torque de inserção dos implantes foi de 32N para o grupo controle, e 45N para o grupo teste (p < 0,0001). Taxa de sucesso no grupo controle foi de 93,02% e 100% no grupo teste. Análise histológica apresentou no grupo controle osso alógeno residual com lacunas osteocíticas vazias e padrão lamelar; osso neoformado com lacunas osteocíticas com osteócitos viáveis e padrão imaturo; osteoblastos em íntimo contato matriz osteóide, formando pontes entre os blocos de osso alógeno e osso neoformado; osteoclastos em proximidade às áreas remodelação óssea; ausência de sinais de infiltrado inflamatório; tecido conjuntivo; e no grupo teste, todos os ítens acima e osso bovino mineral. Histomorfometria: material enxertado remanescente (p = 0,74); osso alógeno remanescente (35.78% ± 6.21% grupo controle, 19.72% ± 10.42% grupo teste; p < 0,0001); OBM remanescente no grupo teste (14,78% ± 8,67); osso neoformado (11.94% ± 1.71% grupo controle, 25.79% ± 8.76% grupo teste; p < 0,001); osso total (47.72% ± 5.6% grupo controle, 58.96% ± 8.1% grupo teste; p < 0,001); tecido conjuntivo (52.27% ± 5.6% grupo controle, 41.45% ± 8.4% grupo teste; p < 0,01). Adicionar OBM ao osso alógeno em cirurgias de levantamento de seio maxilar mostrou-se uma técnica de enxertia eficaz para a instalação de implantes. Resultou em maior torque de inserção, porcentagens maiores de osso neoformado e osso total, permitindo a instalação de implantes e reabilitação protética funcional. / Allograft fresh frozen bone and Bio-Oss are knows as autogenous bone materials substitutes in maxillary sinus lifting. The aim of this study was to evaluate clinical, histological and histomorphometrically the process of repair with and without the association of BBM in maxillary sinus augmentation. In this prospective, randomized, comparative case series study, 34 maxillary sinuses were augmented, which had a residual bone ridge with a maximum height of 5 mm in maxillary sinus reconstruction region at the time for surgery of maxillary sinus prior to rehabilitation by implants. Patients were divided into a) control group: seventeen (17) grafted maxillary sinuses with only allograft bone and b) test group: 17 maxillary sinuses rehabilitated with allograft bone and BBM in a 2:1 ratio. Six months after grafting, at time of implant placement, bone samples were collected using a trephine burr for histological and histomorphometrical analysis. The research data were subjected to Student\'s t test for independent samples used for comparisons between two groups, Mann - Whitney and correlation tests were applied. 29 patients with a mean age of 51.32 years (± 6.44), were divided into control group (17) and test (12), with 34 maxillary sinuses evaluated in total. There was no statistical difference between the groups regarding to age (p = 0.23) and gender (p = 0.56). Median insertion torque of the implants was 32N for the control group and 45N for the test group (p < 0.0001). Survival rate in the control group was 93.02% and 100% in the test group. Histological analysis showed, at the control group, residual allograft bone with empty osteocytic lacunae and lamellar pattern; newly formed bone with osteocytic lacunae with viable osteocytes and immature pattern; osteoblasts in close contact with osteoid matrix, forming bridges between the blocks of allograft bone and new bone formation; osteoclasts in bone remodeling surrounding areas; no evidence of inflammatory infiltrate; connective tissue; and in the test group, all the items above and bovine bone mineral. Histomorphometry: graft remaining material (p = 0.74); remaining allogenous bone (35.78% ± 06.21% control group, 19.72% ± 10:42% test group, p < 0.0001); BBM remaining in the test group (14.78% ± 8.67); newly formed bone (11.94% ± 1.71% control group, 25.79% ± 8.76% test group, p < 0.001); total bone (47.72% ± 5.6% control group, 58.96% ± 8.1% test group, p < 0.001); connective tissue (52.27% ± 5.6% control group, 41.45% ± 8.4% test group, p < 0.01). Adding bovine bone mineral to allogenous bone in maxillary sinus surgery proved to be an effective technique of grafting for implant placement. It resulted in higher insertion torque, higher percentages of new bone formation and total bone, allowing installation of implants and functional loading.
214

Untersuchungen zur Entwicklung der kardiorespiratorischen Interaktion anhand gemeinsamer Rhythmen von Atmung und Herzaktion: Longitudinalstudie der ersten sechs Lebensmonate gesunder Säuglinge

Aikele, Peter 16 June 1998 (has links)
Die vorliegende Arbeit untersuchte die Entwicklung nieder-und hochfrequenter rhythmischer kardiorespiratorischer gesunder Säuglinge. An 15 Probanden erfolgten im Schlaf im ersten Lebenshalbjahr jeweils 13 Messungen mit EKG-Ableitung und induktionsplethysmographischer Registrierung der thorakalen Atemexkursion. Schlafstadienbezogen erfolgten: · die Messung der Amplitude der respiratorischen Sinusarrhythmie (RSA), · die Bestimmung der größten negativen Korrelation zwischen Atemsignal und Herzperiodendauer-Zeitreihe (Kreuzkorrelationskoeffizient, KKK) mit der dazugehörigen Phasenverschiebung mittels Berechnung der Kreuzkorrelationsfunktion und · die Auswertung der Kohärenzspektren von Atmung und Herzaktion. RSA und KKK im ruhigen Schlaf nehmen im Verlauf des ersten Lebenshalbjahres zu. Der Verlauf ist nicht geradlinig, sondern weist signifikante Minima in den ersten Lebenstagen und am Ende der dritten Lebenswoche auf. Die Phasenverschiebung zwischen Atmung und RSA zeigt im ruhigen Schlaf Maxima am 7. und 21. Lebenstag ohne deutlichen Trend innerhalb des Beobachtungszeitraumes. RSA und KKK sind vom ersten Lebenstag an mit Atemfrequenz und Herzfrequenz negativ korreliert. RSA und KKK sind schlafstadienabhängig. Im Gegensatz zum ruhigen Schlaf konnte im aktiven Schlaf weder eine meßbare RSA, noch ein signifikanter KKK gefunden werden. Im Kohärenzspektrum waren jedoch ab dem 150. Lebenstag auch im aktiven Schlaf signifikante gemeinsame Rhythmen im Atemfrequenzbereich nachweisbar. Mit Hilfe der Kohärenzspektren konnten gemeinsame niederfrequente Rhythmen in Atmung und Herzaktion nur in 5.1 % aller Messungen im ruhigen Schlaf und nur in 3.1 % im aktiven Schlaf nachgewiesen werden. Die untersuchten Parameter der Interaktion von Atmung und Herzfrequenz Neugeborener unterscheiden sich von denen Erwachsener in den Absolutwerten. Für RSA und Phasenverschiebung konnte zeigte sich jedoch, daß sich die Werte Erwachsener und Neugeborener nur an verschiedenen Punkten einer gemeinsamen "Arbeitskurve" befinden. Die Ergebnisse lassen auf eine schon zum Zeitpunkt der Geburt vorhandene Reife der kardiorespiratorischen Interaktion schließen. / In the present paper the development of rhythmic cardiorespiratory interactions in low and high frequency ranges were investigated in healthy infants. Data come from a longitudinal study of 14 infants, who were examined for 13 times during sleep during the first 6 months of live. The electrocardiogram and the thoracic respiratory effort were recorded. For quiet and active sleep the following parameters of cardiorespiratory interaction were analysed: · the amplitude of respiratory sinus arrhythmia (RSA), · the highest negative correlation (KKK) and the corresponding phase delay between respiratory signal and time series of heart period duration by means of calculating the cross correlation function and · the coherence in the low and high frequency range. RSA and KKK increase in the first 6 months of live. The course is not linear and has maxima in the first days and at the end of third week. The phase delay shows maxima at 7 th and 21 st day. RSA and KKK are negatively correlated with the respiratory rate and the heart rate from the first day of life up to the 6 th month of life. RSA and KKK depend on sleep state. In opposition to quiet sleep in active sleep neither a measurable RSA nor a significant KKK were found. Contrary, the coherence spectra showed common rhythms in the frequency range of the respiratory rate in the 5 th and 6 th month during active sleep. In the low frequency range common rhythms were observed only seldom, i.e. in 5.1 % of all measurements during quiet sleep and in 3.1 % during active sleep. The analysed parameters of cardiorespiratory interaction of newborns are different from that of adults regarding the absolute values. However the data suggest that the values of newborns and adults represent only different adjustments of a comparable control system. The results indicate a mature cardiorespiratory interaction in healthy newborns.
215

Enseignement de la fonction sinus au deuxième cycle du secondaire par le biais de la modélisation et d'outils technologiques

Lazli, Salima 01 1900 (has links) (PDF)
Dans cette recherche est abordé l'apprentissage de la fonction sinus par un processus de modélisation. La littérature nous montre, qu'à des fins de résolution, les élèves éprouvent des difficultés à traduire des situations concrètes en modèles mathématiques (Gravemeijer). De notre point de vue, la modélisation avec la manipulation combinée d'artefacts (au sens de Rabardel) physiques et technologiques peut supporter cet apprentissage. Puisque dans la pratique, la modélisation mathématique est surtout utilisée pour l'enseignement des relations fonctionnelles (O'Callaghan), et que l'apprentissage des fonctions sinus engendre énormément de difficultés (Kendal et Stacey), notre objectif est d'observer l'apprentissage des fonctions sinus à partir de la modélisation d'une situation donnée. Pourrions-nous arriver à cet objectif en utilisant des artefacts (physiques et technologiques)? Globalement, la recherche a suivi le modèle de l'ingénierie didactique. Lors de l'expérimentation nous avons précisément retenu la méthode d'enseignement ACODESA (Hitt), à cause du caractère social de construction des connaissances qu'elle permet. Cette expérimentation s'est déroulée en septembre 2010 sur sept séances de 60 minutes. Huit élèves de secondaire 5 ont participé volontairement à cette recherche. En début d'expérimentation, les élèves connaissaient les relations trigonométriques dans le triangle (secondaire 4), mais non la forme fonctionnelle du sinus. Dans un environnement d'apprentissage collaboratif, le travail sur la situation avec des artefacts physiques et technologiques a permis de récolter des données. Ces dernières ont été très riches en apprentissages pour moi en tant que chercheuse. En effet, l'analyse de ces données a permis de constater qu'en début d'apprentissage, à cause d'une rupture avec le contrat didactique habituel, les élèves éprouvent de la difficulté à commencer le processus de modélisation. Une fois le processus enclenché, les élèves construisent des modèles subséquents qui les amènent vers la représentation algébrique de la fonction sinus. Par contre, lors de la dernière étape de réflexion, allouée pour la déduction de l'expression algébrique, les élèves ne retournent pas vers la situation, ni même vers la table des valeurs, mais plutôt vers des savoirs acquis dans leur classe de mathématiques. Ils se sont trouvés en face de contradictions cognitives. Ce n'est qu'après un long moment de réflexion et de discussions, que les élèves ont dépassé ces contradictions et ont finalement proposé une expression algébrique qui fait intervenir le sinus. Cette approche a permis à des élèves d'une même classe d'atteindre un savoir à partir de manipulations d'artefacts et de discussions. Les échanges ont permis de combler les manques engendrés à la fois par la manipulation d'artefacts physiques et par la manipulation d'artefacts technologiques, dans une ambiance d'échanges et de collaboration. ______________________________________________________________________________ MOTS-CLÉS DE L’AUTEUR : Fonction sinus, modélisation, technologies, instrumentation, représentations.
216

Spätresultate nach minimalinvasiver Sinusbodenaugmentation / Long-term results after minimally invasive sinus floor augmentation

Blendermann, Katja 15 November 2011 (has links)
No description available.
217

Estudo da identificação humana por meio da imaginologia dos seios frontais.

Almeida, Manuella Santos Carneiro 13 March 2012 (has links)
Made available in DSpace on 2015-05-14T12:56:00Z (GMT). No. of bitstreams: 1 Arquivototal.pdf: 2176646 bytes, checksum: 1bc824e5cb69d2fcdee753f80f5eb8df (MD5) Previous issue date: 2012-03-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to verify the applicability of parameters for human identification using the frontal sinuses, used by Tatlisumak et al. (2007), using axial and coronal reconstructions of CBCT and extraoral radiographs. From 58 dry disjointed skulls existing in the Management of Legal Medicine of Paraiba (PB-GEMOL) and University Center of Joao Pessoa, UNIPÊ, 26 skulls were selected. The acquisition of anteroposterior radiographs of the skull and lateral view were obtained through X-ray machine pan Rotograph Plus ® (Dabi Atlante Ltda., Ribeirão Preto, São Paulo, Brazil) and the CT at New iCAT device Generation ® (Imaging Sciences International, Pennsylvania, USA), adopting a specific methodology in order to standardize the tests to obtain and ensure the reproducibility of the study. The images were evaluated by two examiners calibrated in darkened environment and in two different times, with a minimum interval of one week. Assessments of axial and coronal reconstructions were performed with the aid of a 23 "program and iCat Vision (Imaging Sciences International, Pennsylvania, USA). For evaluation of extraoral radiographs were traced on paper made using ultrafan of 600 lux light box with mask and measurements with the aid of a high precision digital caliper Mitutoyo series 167 (Mitutoyo, Suzano, Brazil). Categorical variables were discrete and analyzed using the kappa test and continuous variables by Correlation Coefficient of Concordance Lin. Methods of analysis by cone beam CT and radiographic were mostly consistent, with only a few variables with unsatisfactory results (capd, and dpele dpontalt). For categorical variables and discrete intra-and inter-was great-perfect for both methods, as continuous variables showed moderate to excellent results. It is concluded that: the methodology proposed in this paper, using the parameters of the job Tatlisumak et al. (2007), are applicable and reliable in extraoral radiographs (X-rays AP and lateral radiographs of the skull face) and axial and coronal reconstructions of CBCT for human identification by frontal sinus, intra-and inter the parameters used by Tatlisumak et al. (2007) with CBCT imaging modality varies from substantial to excellent, and moderate to excellent radiographic images, there is a greater power of reproducibility and accuracy of the proposed method using the axial and coronal reconstructions of CBCT taking extraoral radiographs also reliability , the least consistent variable in the analysis by the images of CBCT is a measure capd (poor agreement), while the radiographic images and are dpele dpontalt (bad matches). This result indicates that these parameters are more susceptible to errors by evaluators, since it needs to use multiple points of reference for their measurements. / O objetivo neste estudo foi verificar a aplicabilidade de parâmetros de identificação humana por meio dos seios frontais, utilizados por Tatlisumak et al. (2007), com auxílio das reconstruções axiais e coronais de tomografia computadorizada de feixe cônico (TCFC) e radiografias extrabucais. De um universo de 58 crânios secos desarticulados existentes na Gerência Executiva de Medicina e Odontologia Legal da Paraíba (GEMOL-PB) e Centro Universitário de João Pessoa, Unipê, foram selecionados 26 crânios. As aquisições das imagens radiográficas póstero-anterior de crânio e lateral de face, foram obtidas por meio do aparelho de raios X panorâmico Rotograph Plus® (Dabi Atlante Ltda., Riberão Preto, São Paulo, Brasil) e as tomográficas, pelo aparelho iCAT New Generation® (Imaging Sciences International, Pennsylvania, EUA), adotando-se uma metodologia específica como forma de padronizar a obtenção dos exames e garantir a reprodutibilidade do estudo. As imagens foram avaliadas por dois examinadores previamente calibrados, em ambiente escurecido e em dois tempos distintos, com um intervalo mínimo de uma semana. As avaliações das reconstruções axiais e coronais foram realizadas com o auxílio de um monitor de 23 e programa iCat Vision (Imaging Sciences International, Pennsylvania, EUA). Para avaliação das imagens radiográficas extrabucais, foram realizados traçados em papel ultrafan utilizando negatoscópio de 600 lux com máscara e as mensurações com auxílio de um paquímetro digital de alta precisão Mitutoyo série 167 (Mitutoyo Sul Americana, Suzano, Brasil). As variáveis categóricas e discretas foram analisadas por meio do teste kappa e as variáveis contínuas pelo Coeficiente de Correlação de Concordância de Lin. Os métodos de análise pelas tomografias de feixe cônico e radiográficas foram em sua maioria concordantes, apresentando apenas algumas variáveis com resultados insatisfatórios (capd, dpele e dpontalt). Para as variáveis categóricas e discretas houve concordância intra e interexaminadores de ótima a perfeita em ambos os métodos, já as variáveis contínuas apresentaram resultados de moderada a excelente. Conclui-se que: a metodologia proposta no presente trabalho, utilizando os parâmetros do trabalho de Tatlisumak et al. (2007), são aplicáveis e confiáveis em radiografias extrabucais (radiografias PA de crânio e radiografias laterais de face) e reconstruções axiais e coronais de TCFC para a identificação humana pelos seios frontais; a concordância intra e interexaminador nos parâmetros utilizados por Tatlisumak et al. (2007) com a modalidade de imagem TCFC varia de boa a excelente; e de moderada a excelente nas imagens radiográficas; há um maior poder de reprodutibilidade e precisão do método proposto utilizando as reconstruções axiais e coronais de TCFC, tendo as radiografias extrabucais também confiabilidade; a variável menos concordante na análise pelas imagens de TCFC é a medida capd (concordância ruim); já pelas imagens radiográficas são dpele e dpontalt (concordâncias ruins). Tal resultado indica que estes parâmetros são mais passíveis de erros por parte dos avaliadores, uma vez que deve-se utilizar vários pontos de referência para suas mensurações.
218

Osseointegração de implantes usinados e oxidados em seio maxilar preenchido por coágulo com ou sem osso autógeno: estudo histológico, histométrico e de RFA em macacos

Palma, Vinícius Canavarros [UNESP] 28 November 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-11-28Bitstream added on 2014-06-13T20:01:38Z : No. of bitstreams: 1 palma_vc_dr_araca.pdf: 5314459 bytes, checksum: f4667d024f4919ee6a40de880d461e25 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo experimental foi comparar histologicamente o preenchimento do assoalho do seio maxilar por coágulo local com ou sem a associação de osso autógeno (controle), bem como investigar a osseointegração em duas diferentes superfícies de implante sob essas condições, através de medidas histométricas, análises histológicas e em freqüência de ressonância (RFA). Quatro macacos prego (tufted capuchin) tiveram todos os pré-molares e os primeiros molares superiores extraídos. Após quatro meses de reparo, os animais foram submetidos a cirurgia para acessar o assoalho do seio maxilar, através de uma janela óssea, para elevação da membrana do seio. O seio direito foi deixado para que se reparasse espontaneamente (somente coágulo), enquanto o esquerdo foi preenchido com enxerto ósseo autógeno. A membrana dos seios foram mantidas elevadas pela inserção simultânea de dois implantes (um usinado e outro oxidado eletroliticamente, Sistema Branemark®, Nobel Biocare) em cada lado da maxila. A estabilidade dos implantes foi acessada através da freqüência de ressonância (RFA, Ostell®) no momento da fixação dos implantes e no dia do sacrifício. Com a injeção de fluorocromos foi possível investigar o processo de neoformação óssea nos animais bem como relacioná-lo às diferentes superfícies dos implantes. Os animais foram sacrificados 6 meses após a cirurgia para análise histológica e de histomorfometria (contato-osso-implante - BIC, área de osso nas roscas - BA, e área de osso em um retângulo desenhado - BAR). Concluímos que não houve diferença entre o seio preenchido somente com coágulo local e o seio preenchido com osso autógeno, em relação à RFA, BIC, BA e BAR... / This experimental study aimed at comparing histologically the use of coagulum alone or autogenous bone graft (control) for sinus floor augmentation procedures as well as investigating the role played by implants surface on osseointegration under such circumstances, as measured by histological, histometric and resonance frequency analysis (RFA). Four tufted capuchin monkeys had all upper premolars and 1st molar extracted bilaterally. Four months later the animals underwent maxillary sinus floor augmentation surgery using the window technique. The right sinus was left to heal spontaneously (coagulum alone), whilst the left sinus was filled with autogenous bone graft. The Schneider's membrane was kept elevated by insertion of two implants (machined and oxidized, Bränemark System) in both sinuses. Implant stability was assessed through resonance frequency analysis (RFA, Osstell) at installation and at sacrifice. The pattern of bone formation in all experimental sites as well as related to the different implants surface was investigated using fluorochromes. The animals were sacrificed 6 months after MSFA for histology and histomorphometry (bone-to-implant contact - BIC, bone area in threads - BA, and bone area in rectangle - BAR). The results showed no difference between coagulum and bone graft sites regarding RFA, BIC, BA and BAR. As to BIC, the oxidized implants exhibited improved integration compared with machined ones. Oxidized implants showed higher BA compared to machined implants in bone grafts. The amount of bone tissue do not differ in coagulum alone and autogenous bone sites. Histologically, new bone is frequently deposited in contact with Schneider's membrane in coagulum alone sites, confirming the osseoinductive potential of the membrane. The oxidized implants should be preferred to machined implants in sinus floor augmentation procedures.
219

Reconhecimento semi-automático de sinus frontais para identificação humana forense baseado na transformada imagem-floresta e no contexto da forma /

Falguera, Juan Rogelio. January 2008 (has links)
Orientador: Aparecido Nilceu Marana / Banca: Adilson Gonzaga / Banca: Humberto Ferasoli Filho / Resumo: Diversos métodos biométricos baseados em características físicas do corpo humano como impressão digital, face, íris e retina têm sido propostos para identificação humana. No entanto, para a identificação post-mortem, tais características biométricas podem não estar disponíveis. Nestes casos, partes do esqueleto do corpo humano podem ser utilizadas para identificação, tais como dentes, tórax, vértebras, ombros e os sinus frontais. Investigações anteriores mostraram, por meio de técnicas manuais para extração de características, que os padrões dos sinus frontais são altamente variáveis entre indivíduos distintos e únicos para cada indivíduo. Esta dissertação de mestrado tem por objetivo propor um método computacional para o reconhecimento de sinus frontais para identificação humana post-mortem em aplicações forenses. Para tanto, foram avaliados métodos de segmentação de imagens de radiografias anteroposteriores de sinus frontais. O método baseado na Transformada Imagem-Floresta demonstrou ser eficiente para segmentação dos sinus frontais das imagens de radiografias, exigindo mínima intervenção humana. Foram também investigadas e implementadas técnicas para extração de descritores geométricos e descritores baseados nas formas dos sinus frontais. Experimentos realizados em um banco de imagens contendo 90 radiografias anteroposteriores de 29 indivíduos mostraram que a técnica de extração de características baseada nos descritores de contexto da forma foi a mais eficaz, propiciando taxas de erro igual (EER) e de recuperações corretas (CRR) de 3,73% e 95,5%, respectivamente. Os resultados obtidos nos experimentos corroboram os encontrados na literatura sobre a individualidade dos sinus frontais e sua viabilidade em termos de precisão e usabilidade para a identificação humana post-mortem. Palavras-chave: Biometria, identificação... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Several methods based on Biometrics such as fingerprint, face, iris, and retina have been proposed for person identification. However, for postmortem identification such biometric measurements may not be available. In such cases, parts of the human skeleton can be used for identification, such as teeth, thorax, vertebrae, shoulders, and frontal sinus. Previous investigations showed, by means of manual features extraction techniques, that frontal sinus patterns are highly variable for distinctive individuals and unique for each one. The objective of this master thesis is to propose a computational method for frontal sinus recognition for postmortem human identification in forensic applications. In order to achieve this, methods for frontal sinus segmentation from anteroposterior radiographs were evaluated. The method based on Image-Foresting Transform has shown itself efficient in frontal sinus segmentation from radiograph images, demanding minimal human intervention. After the segmentation, techniques for extracting frontal sinus geometrical and shape-based descriptors were investigated and implemented. Experiments over a database containing 90 anteroposterior radiograph images from 29 individuals have shown that the features extraction techniques based on shape context descriptors were the most efficient, providing equal error (EER) and correct retrievals (CRR) rates of 3.73% and 95,5%, respectively. The results obtained in our experiments confirm the outcomes described in literature about the individuality of the frontal sinus and its feasibility in terms of precision and usability for postmortem human identification. Keywords: Biometrics, forensics human... (Complete abstract click electronic access below) / Mestre
220

Osseointegração de implantes usinados e oxidados em seio maxilar preenchido por coágulo com ou sem osso autógeno : estudo histológico, histométrico e de RFA em macacos /

Palma, Vinícius Canavarros. January 2006 (has links)
Resumo: O objetivo deste estudo experimental foi comparar histologicamente o preenchimento do assoalho do seio maxilar por coágulo local com ou sem a associação de osso autógeno (controle), bem como investigar a osseointegração em duas diferentes superfícies de implante sob essas condições, através de medidas histométricas, análises histológicas e em freqüência de ressonância (RFA). Quatro macacos prego (tufted capuchin) tiveram todos os pré-molares e os primeiros molares superiores extraídos. Após quatro meses de reparo, os animais foram submetidos a cirurgia para acessar o assoalho do seio maxilar, através de uma janela óssea, para elevação da membrana do seio. O seio direito foi deixado para que se reparasse espontaneamente (somente coágulo), enquanto o esquerdo foi preenchido com enxerto ósseo autógeno. A membrana dos seios foram mantidas elevadas pela inserção simultânea de dois implantes (um usinado e outro oxidado eletroliticamente, Sistema Branemark®, Nobel Biocare) em cada lado da maxila. A estabilidade dos implantes foi acessada através da freqüência de ressonância (RFA, Ostell®) no momento da fixação dos implantes e no dia do sacrifício. Com a injeção de fluorocromos foi possível investigar o processo de neoformação óssea nos animais bem como relacioná-lo às diferentes superfícies dos implantes. Os animais foram sacrificados 6 meses após a cirurgia para análise histológica e de histomorfometria (contato-osso-implante - BIC, área de osso nas roscas - BA, e área de osso em um retângulo desenhado - BAR). Concluímos que não houve diferença entre o seio preenchido somente com coágulo local e o seio preenchido com osso autógeno, em relação à RFA, BIC, BA e BAR...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This experimental study aimed at comparing histologically the use of coagulum alone or autogenous bone graft (control) for sinus floor augmentation procedures as well as investigating the role played by implants surface on osseointegration under such circumstances, as measured by histological, histometric and resonance frequency analysis (RFA). Four tufted capuchin monkeys had all upper premolars and 1st molar extracted bilaterally. Four months later the animals underwent maxillary sinus floor augmentation surgery using the window technique. The right sinus was left to heal spontaneously (coagulum alone), whilst the left sinus was filled with autogenous bone graft. The Schneider's membrane was kept elevated by insertion of two implants (machined and oxidized, Bränemark System) in both sinuses. Implant stability was assessed through resonance frequency analysis (RFA, Osstell) at installation and at sacrifice. The pattern of bone formation in all experimental sites as well as related to the different implants surface was investigated using fluorochromes. The animals were sacrificed 6 months after MSFA for histology and histomorphometry (bone-to-implant contact - BIC, bone area in threads - BA, and bone area in rectangle - BAR). The results showed no difference between coagulum and bone graft sites regarding RFA, BIC, BA and BAR. As to BIC, the oxidized implants exhibited improved integration compared with machined ones. Oxidized implants showed higher BA compared to machined implants in bone grafts. The amount of bone tissue do not differ in coagulum alone and autogenous bone sites. Histologically, new bone is frequently deposited in contact with Schneider's membrane in coagulum alone sites, confirming the osseoinductive potential of the membrane. The oxidized implants should be preferred to machined implants in sinus floor augmentation procedures. / Orientador: Osvaldo Magro Filho / Coorientador: Luiz Antônio Salata / Banca: Luis Eduardo Marques Padovan / Banca: Renato Mazzonetto / Banca: João Gualberto Cerqueira Luz / Banca: Idelmo Rangel Garcia Júnior / Banca: Paulo Sérgio Perri de Carvalho / Doutor

Page generated in 0.063 seconds