• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 97
  • 11
  • 10
  • 10
  • 9
  • 9
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 180
  • 180
  • 119
  • 62
  • 59
  • 45
  • 27
  • 24
  • 24
  • 22
  • 22
  • 20
  • 19
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Gestión eficiente de los convertidores de potencia conectados al bus DC de una Microrred híbrida de generación distribuida

Salas Puente, Robert Antonio 22 March 2019 (has links)
Tesis por compendio / [ES] Dos aspectos críticos en la operación de una microrred son las estrategias de control y gestión de potencia implementadas, las cuales son esenciales para proporcionar su buen funcionamiento. La aplicación adecuada de dichas estrategias permite compensar los desequilibrios de potencia causados por la discontinuidad de la generación y de la demanda de energía en las microrredes. En este sentido, el objetivo global de estas estrategias de gestión es equilibrar adecuadamente el flujo de potencia en la microrred, mediante la aplicación de diferentes algoritmos que permiten cumplir con los criterios de estabilidad, protección, balance de potencia, transiciones, sincronización con la red y gestión adecuada de la microrred. En el caso de microrredes de pequeña escala de potencia con bajo número de generadores y sistemas de almacenamiento distribuidos, las estrategias de control centralizado ofrecen un alto nivel de flexibilidad para lograr funcionalidades avanzadas en la microrred y una adecuada distribución de la potencia entre los convertidores que la conforman. Esta tesis se ha enmarcado en el contexto de algoritmos de gestión centralizada de potencia de una microrred de generación distribuida en modo conectado a red. Los algoritmos presentados se pueden aplicar a los convertidores de potencia conectados al bus DC de una microrred AC/DC híbrida o en una microrred de DC, donde el despacho de potencia es observado y gestionado por un controlador central. Este último adquiere datos del sistema mediante una infraestructura de comunicaciones y estima la potencia que gestionará cada uno de los convertidores de potencia, sistemas de almacenamiento y cargas en funcionamiento. En este estudio se muestra la validación experimental de las estrategias de gestión aplicadas en la microrred desde el enfoque del comportamiento de los convertidores de potencia, de las baterías y las cargas ante dicha gestión. Se verifica la estabilidad de la microrred sometiendo a los convertidores a diferentes escenarios de funcionamiento. Estos escenarios pueden ser fluctuaciones en la irradiación, la demanda, el estado de carga de las baterías, los límites máximos de exportación/importación de potencia desde/hacia la microrred hacia/desde la red principal y de la tarifa eléctrica. Adicionalmente, se propone un sistema de almacenamiento de energía en baterías encargado de mantener el equilibrio de potencia en el bus de DC de la microrred que permite aprovechar las fuentes de generación renovables presentes en la microrred y maximizar el tiempo de servicio de las baterías mediante la aplicación de un algoritmo de carga de las baterías. Este último se ajusta al procedimiento de carga especificado por el fabricante, estableciendo las tasas de carga en función de los escenarios en que la microrred se encuentre. El procedimiento de carga en las baterías es fundamental para garantizar las condiciones adecuadas de operación de las mismas, ya que toman en consideración los parámetros establecidos por el fabricante, como son: tasas de carga/descarga, tensión máxima de carga, temperaturas de operación, etc. / [CA] Dos dels aspectes crítics en l'operació d'una micro-xarxa són les estratègies de control i gestió de potència implementades, les quals són essencials per proporcionar el seu bon funcionament. L'aplicació adequada de dites estratègies permet compensar els desequilibris de potència causats per la discontinuïtat de la generació i demanda d'energia en les micro-xarxes. En aquest sentit, l'objectiu global de les nomenades estratègies de gestió és equilibrar adequadament el flux de potència en la micro-xarxa mitjançant l'aplicació de diferents algoritmes que permeten complir amb els criteris d'estabilitat, protecció, balanç de potència, transicions, sincronització amb la xarxa i gestió adequada de la micro-xarxa. En el cas de micro-xarxes de potència a petita escala i amb baix nombre de generadors i sistemes d'emmagatzematge distribuïts, les estratègies de control centralitzades ofereixen un alt nivell de flexibilitat per aconseguir funcionalitats avançades en la micro-xarxa i una adequada distribució de la potència entre els convertidors que la conformen. Aquesta tesi s'ha emmarcat al context d'algoritmes de gestió centralitzada de potència d'una micro-xarxa de generació distribuïda en mode de connexió a xarxa. Els algoritmes presentats es poden aplicar als convertidors de potència connectats al bus DC d'una micro-xarxa AC/DC hibrida o en una micro-xarxa de DC, on el despatx de potència és observat i gestionat per un controlador central. Aquest últim adquireix dades del sistema mitjançant una infraestructura de comunicacions i estima la potència que gestionarà cadascun dels convertidors de potència, sistemes d'emmagatzematge i càrregues en funcionament. En aquest estudi es mostren la validació experimental de les estratègies de gestió aplicades en la micro-xarxa des d'un enfocament dels convertidors de potència, de les bateries i les càrregues davant d'aquesta gestió. Es verifica l'estabilitat de la micro-xarxa exposant als convertidors a diferents escenaris de funcionament. Aquest escenaris poden ser fluctuants en la irradiació, la demanda, l'estat de càrrega de les bateries, els límits màxims d'exportació/importació de potència des de/cap a la micro-xarxa cap a/des de la xarxa principal i de la tarifa elèctrica. Addicionalment, es proposa un sistema d'emmagatzematge d'energia en bateries encarregats de mantindre l'equilibri de potència al bus DC de la micro-xarxa i que permet aprofitar les fonts de generació renovables presents en la micro-xarxa i maximitzar el temps de servei de les bateries mitjançant l'aplicació d'un algoritme de càrrega de bateries. Aquest últim s'ajusta al procediment de càrrega especificat pel fabricant, establint les taxes de càrrega en funció dels escenaris en que la micro-xarxa es trobe. El procediment de càrrega a les bateries es fonamental per garantir les condicions adequades d'operació de les mateixes, ja que prenen en consideració els paràmetres establerts pel fabricant, com ara són: taxes de càrrega/descàrrega, tensió màxima de càrrega, temperatures d'operació, etc. / [EN] Two critical aspects in microgrids operation are the control and power management strategies, which are essential for their efficient operation. The adequate application of these strategies allows compensating the power imbalance caused by the discontinuity in the energy generation or changes in the power demand of the microgrid. In this sense, the overall objective of these power management strategies is to keep the power balance between the generation and the demand in the microgrid through the application of different algorithms that fulfill the criteria of stability, protection, smooth transitions and synchronization with the main grid. In the case of small-scale microgrids with a low number of distributed generators and energy storage systems, the centralized control strategies offer a higher level of flexibility to achieve advanced features in the microgrid and for the suitable power sharing between the converters that compose it. This thesis has been focused on centralized power management algorithms of a microgrid working in grid connected mode. These algorithms can be applied to the power converters connected to the DC bus of both hybrid AC/DC and DC microgrids, where the power dispatch is controlled by a central controller which acquires system data through a communication infrastructure and sets the power to be managed by each of the converters under operation. In this thesis, the experimental validation of the power management strategies of the microgrid is presented, from the point of view of the behavior of the power converters, batteries and loads. It is provided with a realistic evaluation under different microgrid operation scenarios. These scenarios were sudden changes of the irradiation, load, state of charge, the maximum power to be exported/imported from/to the microgrid to/from the grid, and the electricity tariff. Additionally, it is proposed a battery energy storage system that keeps the power balance at the DC bus of the microgrid, taking advantage from the renewable energy sources and adjusting the battery energy storage through a suitable charging procedure specified by the manufacturer. The proposed procedure changes the charging parameters of the batteries depending on the microgrid states. Its goal is to extend the service time of batteries and to allow proper energy management in the system. / Salas Puente, RA. (2019). Gestión eficiente de los convertidores de potencia conectados al bus DC de una Microrred híbrida de generación distribuida [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/118658 / Compendio
162

[pt] AVALIAÇÃO ECONÔMICA DE USINAS VIRTUAIS DE ENERGIA SOLAR E ARMAZENAMENTO DE ENERGIA EM BATERIAS NO CONTEXTO DA LEI 14.300/2022 DESENHADO A PARTIR DE UM MODELO ESTOCÁSTICO DE PROGRAMAÇÃO LINEAR INTEIRA MISTA / [en] ECONOMIC EVALUATION OF VIRTUAL POWER PLANTS COMBINING PHOTOVOLTAIC SYSTEMS AND BATTERY ENERGY STORAGE SYSTEMS UNDER LAW 14.300/2022 SCENARIO USING A STOCHASTIC MIXED-INTEGER LINEAR PROGRAMMING MODEL

KARINA MOSQUEIRA VALENTE 20 May 2024 (has links)
[pt] A perspectiva de queda nos preços dos sistemas fotovoltaicos e sistemas de armazenamento de energia elétrica em baterias trouxe a possibilidade de maior viabilidade econômica de projetos envolvendo recursos energéticos distribuídos. No Brasil, a Resolução Normativa 482/2012 regulamentou a micro e mini geração distribuída, estimulando, portanto, a integração desses recursos nas redes de distribuição. Com a promulgação da Lei brasileira 14.300/2022, os projetos de micro e mini geração distribuída foram impactados, uma vez que o sistema de compensação de energia elétrica passou a ser parcial, o que demanda agregar valor aos modelos de negócios baseados em geração distribuída. Este trabalho propõe um modelo de Programação Linear Inteira Mista estocástico com o objetivo de avaliar a viabilidade econômica de usinas virtuais compostas por diferentes configurações de recursos energéticos distribuídos, envolvendo baterias e painéis fotovoltaicos. Para atingir esse propósito, o modelo busca dimensionar o contrato de energia anual ótimo, fornecendo também a operação diária das baterias. Além de levar em consideração os aspectos da Lei 14.300/2022, o modelo incorpora a prática de arbitragem tarifária. Colaborando, assim, com estudos que analisam os impactos regulatórios sobre empreendimentos envolvendo baterias e painéis fotovoltaicos no contexto brasileiro. Com o intuito de abordar o tema de maneira ampla, o modelo proposto foi implementado para recursos energéticos distribuídos organizados como usina virtual, contendo: (i) um sistema fotovoltaico; (ii) um sistema de armazenamento de energia em baterias; (iii) um sistema híbrido (composto por um sistema fotovoltaico e um sistema de armazenamento de energia em baterias); e (iv) o estudo de caso da distribuidora de energia elétrica brasileira Energisa Tocantins. Em todas as aplicações, analisou-se a viabilidade econômica da usina virtual para as tarifas da Energisa Tocantins e outras 34 distribuidoras brasileiras, representando pelo menos uma distribuidora por estado brasileiro. Além disso, foram feitas comparações em relação à data de início de operação da usina virtual, evidenciando o impacto da Lei 14.300/2022 na viabilidade econômica das usinas virtuais analisadas, mostrando, assim, o impacto da referida lei nos projetos de geração distribuída no Brasil. No estudo de caso da distribuidora de energia elétrica brasileira Energisa Tocantins, foi realizada uma análise adicional contemplando aspectos da rede de distribuição da própria Energisa Tocantins, onde os recursos energéticos distribuídos estão alocados. Nessa análise adicional, foram avaliadas as perdas elétricas e seus custos, bem como o perfil de tensão para dois casos de operação das baterias e para o caso base, que seria o caso sem recursos energéticos distribuídos na rede de distribuição Energisa Tocantins. Os resultados evidenciaram que a implementação da Lei 14.300/2022 reduziu a atratividade de projetos envolvendo geração distribuída. No entanto, em sua maioria, considerando os parâmetros adotados deste estudo, esses projetos ainda se mostram viáveis economicamente. Levando em consideração as perdas elétricas e o perfil de tensão, a integração de recursos energéticos distribuídos na rede de distribuição pode trazer benefícios elétricos e redução de custos, dependendo da operação dos recursos energéticos distribuídos, demonstrando sua capacidade de fornecer serviços ancilares ao sistema elétrico. Além disso, os sistemas fotovoltaicos ainda apresentam maior competitividade se comparados com os sistemas híbridos ou os sistemas de armazenamento de energia em baterias, proporcionando retornos financeiros mais atrativos. Por fim, as diferentes amplitudes tarifárias influenciam diretamente na viabilidade de projetos de geração distribuída envolvendo sistemas de armazenamento de energia, já que quanto maior a amplitude tarifária, maior será a arbitragem tarifária que tais sistemas podem proporcionar. / [en] The prospect of declining prices in photovoltaic systems and battery energy storage systems has brought about the possibility of greater economic viability for projects involving distributed energy resources. In Brazil, Regulatory Resolution 482/2012 regulated micro and mini distributed generation, thereby encouraging the integration of these resources into distribution networks. With the enactment of Brazilian Law 14.300/2022, projects involving micro and mini distributed generation were impacted, as the net metering system for electricity became partial, demanding the addition of value to distributed generation-based business models. This work proposes a stochastic Mixed Integer Linear Programming model aimed at evaluating the economic feasibility of virtual power plants composed of different configurations of distributed energy resources, involving batteries and photovoltaic panels. To achieve this purpose, the model seeks to size the optimal annual energy contract, also providing the daily operation of the batteries. In addition to considering the aspects of Law 14.300/2022, the model incorporates tariff arbitrage practice, thus contributing to studies analyzing regulatory impacts on ventures involving batteries and photovoltaic panels in the Brazilian context. In order to comprehensively address the topic, the proposed model was implemented for distributed energy resources organized as virtual power plant, containing: (i) a photovoltaic system; (ii) a battery energy storage system; (iii) a hybrid system (composed of a photovoltaic system and a battery energy storage system); and (iv) the case study of the Brazilian electric utility Energisa Tocantins. In all applications, the economic viability of the virtual power plant was analyzed for the tariffs of Energisa Tocantins and 34 other Brazilian distributors, representing at least one distributor per Brazilian state. Additionally, comparisons were made regarding the start date of operation of the virtual power plant, highlighting the impact of Law 14.300/2022 on the economic viability of the analyzed virtual power plants, thus demonstrating the impact of said law on distributed generation projects in Brazil. In the case study of the Brazilian electric utility Energisa Tocantins, an additional analysis was conducted considering aspects of Energisa Tocantins distribution network, where distributed energy resources are allocated. In this additional analysis, electrical losses and their costs, as well as voltage profiles for two battery operation scenarios and the base case (i.e., the case without distributed energy resources in the Energisa Tocantins distribution network) were evaluated. The results showed that the implementation of Law 14.300/2022 reduced the attractiveness of projects involving distributed generation. However, for the most part, considering the parameters adopted in this study, these projects still demonstrate economic viability. Taking into account electrical losses and voltage profiles, the integration of distributed energy resources into the distribution network can bring electrical benefits and cost reductions, depending on the operation of the distributed energy resources, demonstrating their ability to provide ancillary services to the electrical system. Furthermore, photovoltaic systems still exhibit greater competitiveness when compared to hybrid systems or battery energy storage systems, providing more attractive financial returns. Finally, different tariff amplitudes directly influence the viability of distributed generation projects involving energy storage systems, as the greater the tariff amplitude, the greater the tariff arbitrage that such systems can provide.
163

Machine Learning Algorithms for Energy Trading of Battery Energy Storage Systems : Reinforcement learning for trading energy on dual electricity markets

Haratian, Arash January 2024 (has links)
The battery energy storage system (BESS) holds the promise of becoming an essential element in our energy landscape. With the increasing need for renewable energy and electrification, a BESS serves as backup power, grid frequency balancing, and playing a crucial role in achieving 100% renewable electricity production by 2040 in Sweden. This thesis aims to study intelligent energy trading algorithms for BESS with two markets. The algorithms would allow BESS to trade simultaneously with two markets, day-ahead (energy) market and FCR-N.The problem of trading is solved using reinforcement learning (RL) particularly, multi-agent reinforcement learning (MARL), are proposed as potential solutions for learning energy trading strategies across multiple markets, addressing a gap in current research. In this study two main algorithms are used: Deep Q-networks (DQN), and Advantage Actor-Critic (A2C). These two algorithms are adapted to the MARL’s paradigms. This thesis answers three main questions. First, if any of the MARL variations of the two mentioned algorithms have any advantage over the others. The results suggest that the CTDE variation of A2C performs the best, followed by centralized variation of A2C. Second, the discrete action spaces and continuous action spaces are compared. The algorithms with continuous action spaces achieved higher revenues. The continuous action spaces let the agents decide the exact volumes of the energy to trade. This is while in the discrete action spaces the agents can only choose the volumes from a defined set of values. Third and last, the results from the experiments suggest that trading with two markets results in higher revenue than trading with one market. All the MARL algorithms have higher revenue compared to the simple hard-rule strategy designed for trading with two markets. This thesis shows that the RL and MARL algorithms can be used for creating profitable trading agents and for identifying successful trading strategies.
164

Increasing wind power penetration and voltage stability limits using energy storage systems

Le, Ha Thu 22 September 2010 (has links)
The research is motivated by the need to address two major challenges in wind power integration: how to mitigate wind power fluctuation and how to ensure stability of the farm and host grid. It is envisaged that wind farm power output fluctuation can be reduced by using a specific type of buffer, such as an energy storage system (ESS), to absorb its negative impact. The proposed solution, therefore, employs ESS to solve the problems. The key research findings include a new technique for calculating the desired power output profile, an ESS charge-discharge scheme, a novel direct-calculation (optimization-based) method for determining ESS optimal rating, and an ESS operation scheme for improving wind farm transient stability. Analysis with 14 wind farms and a compressed-air energy storage system (CAES) shows that the charge-discharge scheme and the desired output calculation technique are appropriate for ESS operation. The optimal ESSs for the 14 wind farms perform four or less switching operations daily (73.2%-85.5% of the 365 days) while regulating the farms output variation. On average, the ESSs carry out 2.5 to 3.1 switching operations per day. By using the direct-calculation method, an optimal ESS rating can be found for any wind farm with a high degree of accuracy. The method has a considerable advantage over traditional differential-based methods because it does not require knowledge of the analytical form of the objective function. For ESSs optimal rating, the improvement in wind energy integration is between 1.7% and 8%. In addition, a net increase in grid steady-state voltage stability of 8.3%-18.3% is achieved by 13 of the 14 evaluated ESSs. For improving wind farm transient stability, the proposed ESS operation scheme is effective. It exploits the use of a synchronous-machine-based ESS as a synchronous condenser to dynamically supply a wind farm with reactive power during faults. Analysis with an ESS and a 60-MW wind farm consisting of stall-regulated wind turbines shows that the ESS increases the farm critical clearing time (CCT) by 1 cycle for worst-case bolted three-phase-to-ground faults. For bolted single-phase-to-ground faults, the CCT is improved by 23.1%-52.2%. / text
165

Réjection de perturbation sur un système multi-sources - Application à une propulsion hybride / Disturbance rejection of hybrid energy sources applied in hybrid electric vehicles

Dai, Ping 19 January 2015 (has links)
Ce mémoire porte sur l'étude d'un système de gestion d'énergie électrique dans un système multi-sources soumis à des perturbations exogènes. L'application visée est l'alimentation d'une propulsion hybride diesel/électrique équipée d'un système d'absorption des pulsations de couple. Les perturbations exogènes considérées peuvent être transitoires ou persistantes. Une perturbation transitoire correspond à une variation rapide du couple de charge, due par exemple à une accélération ou une décélération du véhicule. Une perturbation persistante provient du système de compensation des pulsations de couple générées par le moteur thermique. Le premier objectif du contrôle est de maintenir constante la tension du bus continu. Le deuxième objectif est d'absorber dans un système de stockage rapide constitué de super condensateur ces perturbations qui peuvent à terme provoquer une usure prématurée de la batterie. Le troisième objectif est de compenser l'auto-décharge dans le super condensateur en maintenant constante sa tension nominale. Les deux sources (batterie et super condensateur) sont reliées au bus continu par l'intermédiaire de deux convertisseurs boost DC/DC. La commande consiste à piloter les rapports cycliques de chaque convertisseur. C'est un système non linéaire où la commande est multiplicative de l'état. L'approche classique consistant à résoudre les équations Francis-Byrnes-Isidori ne s'applique pas directement dans ce cas où la sortie et la matrice d'interconnection dépendent de la commande. De plus, si cette approche est bien adaptée au rejet de perturbations persistantes, elle montre ces limites pour le rejet de perturbations non persistantes combiné à des objectifs de régulation. Notre approche a consisté à écrire le système sous un formalisme Port-Controlled Hamiltonian et à s'affranchir de la contrainte de la dépendance de la matrice d'interconnection avec la commande en utilisant la théorie des perturbations singulières. La commande du système dégénéré peut ensuite être calculée par une approche passive. Les performances de cette commande ont été testées en simulation et à l'aide d'un banc d'essai expérimental. Les résultats montrent l'efficacité du système d'absorption des différents types de perturbation tout en respectant les deux objectifs de régulation. / This thesis presents the research of energy management in a battery/ultracapacitor hybrid energy storage system with exogenous disturbance in hybrid electric vehicular application. Transient and harmonic persistent disturbances are the two kinds of disturbances considered in this thesis. The former is due to the transient load power demand during acceleration and deceleration, and the latter is introduced from the process of the internal combustion engine torque ripples compensation. Our control objective is to absorb the disturbances causing battery wear via the ultracapacitor, and meanwhile, to maintain a constant DC voltage and to compensate the self-discharge in the ultracapacitor to maintain it operating at the nominal state of charge. The object system is nonlinear due to the multiplicative relation between the input and the state. The traditional approach to solve Francis-Byrnes-Isidori equations cannot be directly applied in this case since the interconnect matrix depends on the control input. Besides, even if this approach is well suited to the rejection of persistent disturbances, it shows the limits for the case of non-persistent disturbances which is also our object. Our contributed control method is realized through a cascade control structure based on the singular perturbation theory. The ultracapacitor current with the fastest motion rate is controlled in the inner fast loop through which we impose the desired dynamic to the system. The reduced system controlled in the outer slow loop is a Hamiltonian system and the controller is designed via interconnection and damping assignment. Simulations and experiments have been carried out to evaluate the control performance. A contrast of the system responses with and without the control algorithm shows that, with the control algorithm, the ultracapacitor effectively absorbs the disturbances; and verifies the effectiveness of the control algorithm.
166

Ultracapacitor/Battery Hybrid Energy Storage Systems for Electric Vehicles

Moshirvaziri, Mazhar 22 November 2012 (has links)
This thesis deals with the design of Hybrid Energy Storage System (HESS) for Light Electric Vehicles (LEV) and EVs. More specifically, a tri-mode high-efficiency non-isolated half-bridge converter is developed for the LEV based HESS applications. A 2 kW, 100 V interleaved two-phase converter prototype was implemented. The peak efficiency of 97.5% and a minimum efficiency of 88% over the full load range are achieved. Furthermore, a power-mix optimizer utilizing the real-time Global Positioning System (GPS) data for the EV based HESS is proposed. For a specific design, it is shown that at the cost of less than 1.5% of the overall energy savings, the proposed scheme reduces the peak battery charge and discharge rates by 76% and 47%, respectively. A 30 kW bi-directional dc-dc converter is also designed and implemented for future deployment of the designed HESS into a prototype EV, known as A2B.
167

Ultracapacitor/Battery Hybrid Energy Storage Systems for Electric Vehicles

Moshirvaziri, Mazhar 22 November 2012 (has links)
This thesis deals with the design of Hybrid Energy Storage System (HESS) for Light Electric Vehicles (LEV) and EVs. More specifically, a tri-mode high-efficiency non-isolated half-bridge converter is developed for the LEV based HESS applications. A 2 kW, 100 V interleaved two-phase converter prototype was implemented. The peak efficiency of 97.5% and a minimum efficiency of 88% over the full load range are achieved. Furthermore, a power-mix optimizer utilizing the real-time Global Positioning System (GPS) data for the EV based HESS is proposed. For a specific design, it is shown that at the cost of less than 1.5% of the overall energy savings, the proposed scheme reduces the peak battery charge and discharge rates by 76% and 47%, respectively. A 30 kW bi-directional dc-dc converter is also designed and implemented for future deployment of the designed HESS into a prototype EV, known as A2B.
168

Materials and thermal storage systems by sensible heat for thermodynamic electro-solar plants / Matériaux et systèmes de stockage thermique en chaleur sensible pour centrales électro-solaires thermodynamiques

Nahhas, Tamar 27 October 2017 (has links)
L'énergie solaire est connue pour sa nature intermittente par rapport aux ressources d’énergie fossile. Cette observation souligne la nécessité d'utilisation d’un système de stockage d'énergie thermique. Le système de stockage thermocline est considéré comme un système de stockage rentable. La présente thèse vise à étudier le potentiel des roches basaltiques et siliceuses comme des candidates matériaux de stockage pour les centrales solaires concentrées. Les études expérimentales des propriétés thermo-physiques et thermomécaniques de ces roches à des températures allant jusqu'à 1000°C montrent que ces roches offrent de bonnes propriétés thermiques par rapport aux matériaux classiques de stockage. L'analyse du système de stockage thermocline sur un lit de roches à air direct est réalisée par une approche numérique. En outre, cette recherche vise également à évaluer l’impact environnementale de ce type de système de stockage en effectuant une analyse comparative de son cycle de vie. Enfin, une étude complémentaire réalisée dans le but de produire une carte d'indice de pertinence a permis d’identifier les zones les plus appropriées pour la construction des centrales solaires en Egypte. L'originalité de cette approche alternative pour le stockage d'énergie thermique est qu’elle combine la performance et la disponibilité des matériaux de stockage tout en réduisant leurs impacts environnementaux et financiers. / Compare to fossil fuel energy resources, solar energy is known for its intermittent nature. This observation highlights the need for the use of a thermal energy storage system. The thermocline storage system is considered as a cost-effective storage system. This thesis aims to study the potential of basalt and silex rocks as candidate storage materials for concentrated solar power plants. Experimental studies of the thermo-physical and thermo-mechanical properties of these rocks at temperatures up to 1000°C show that these rocks offer good thermal properties compared with conventional storage materials. The analysis of the thermocline storage system of air rock-packed bed is carried out using a numerical approach. This research also aims to assess the environmental impact of this type of storage system by conducting a comparative analysis of its life cycle. Finally, a complementary study carried out with the aim of producing a relevance index map made it possible to identify the most suitable areas for the construction of solar power plants in Egypt. The originality of this alternative approach for thermal energy storage is that it combines the performance and availability of storage materials while reducing their environmental and financial impacts.
169

Étude des problèmes d’ordonnancement sur des plates-formes hétérogènes en modèle multi-port

Rejeb, Hejer 30 August 2011 (has links)
Les travaux menés dans cette thèse concernent les problèmes d'ordonnancement sur des plates-formes de calcul dynamiques et hétérogènes et s'appuient sur le modèle de communication "multi-port" pour les communications. Nous avons considéré le problème de l'ordonnancement des tâches indépendantes sur des plates-formes maîtres-esclaves, dans les contextes statique et dynamique. Nous nous sommes également intéressé au problème de la redistribution de fichiers répliqués dans le cadre de l'équilibrage de charge. Enfin, nous avons étudié l'importance des mécanismes de partage de bande passante pour obtenir une meilleure efficacité du système. / The results presented in this document deal with scheduling problems on dynamic and heterogeneous computing platforms under the "multiport" model for the communications. We have considered the problem of scheduling independent tasks on master-slave platforms, in both offline and online contexts. We have also proposed algorithms for replicated files redistribution to achieve load balancing. Finally, we have studied the importance of bandwidth sharing mechanisms to achieve better efficiency.
170

Zpracování neurčitých údajů v databázích / Processing of Uncertain Information in Databases

Morávek, Petr January 2009 (has links)
The following diploma thesis focuses on processing of uncertain information in databases. Uncertain information represents vague customer requests during laptop choice in classic shop purchasing. Effort of the work is to develop a modern e-shop application selling laptops, which is based on expert fuzzy system helping customers to choose a laptop without knowledge of technical specifications and current trends.

Page generated in 0.1023 seconds