• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 2
  • Tagged with
  • 10
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Framtagning av demonstratorer

Birkelöf, Jonas January 2009 (has links)
<p>På Alfred Nobelmuseet i Karlskoga finns en avdelning som kallas Fiffiga huset. Där finns många experiment som besökare kan prova på, samt montrar som visar hur olika tekniska och maskinella apparater fungerar. Till utställningen och öppnandet sommaren 2009 ville de ha två nya demonstratorer. I rapporten kallas dem för reaktionstidsväggen och baklängesprataren. Reaktionstidsväggen skulle mäta besökarens reaktionstid genom att tryckknappar, med inbyggda dioder som slumpvis tänds, trycks ned i rätt ordning. Baklängesprataren skulle spela in besökarens tal och sedan spela upp det baklänges. Tanken var att besökaren skulle försöka prata baklänges och få det att låta rätt vid uppspelning. Arbetet gick ut på att bygga dessa demonstratorer och montera dem i Fiffiga huset. Reaktionstidsväggen styrdes med hjälp av en mikroprocessor ATMega16 från Atmel. Dess jobb var att läsa av knapptryckningar samt skicka information till dioder och display. Även baklängesprataren skulle styras med hjälp av mikroprocessorn ATMega16. En enkel mikrofonförstärkare samt filter till högtalarna skulle anslutas till processorn. Det inbyggda minnet skulle inte räcka till så ett extern minne behövde anslutas.Endast reaktionstidsväggen hann bli färdig inom projektets ramar eftersom all gammal elektronik som medföljde från Nobelmuseet var komplex, samt att många kortslutningar och avbrott gjorde felsökning till en tidskrävande procedur.</p>
2

Ett hus utan tak / A house without a roof

Öhman, Maria January 2015 (has links)
Innan jag började läsa arkitektur var jag dansare i många år. Då låg jag ofta på golvet och tittade i taket. Så pass länge att taket tillslut blev en vägg. Jag har också snurrat mig yr så att rummets gränser suddats ut, så att upp blev ner och ner blev upp. Med den erfarenheten har jag sökt efter ett sätt att radera bort gränsen för vad som är en vägg, ett golv och ett tak. En kulturskola ska vara en plats för lärande, lust och kreativitet. En plats där möjligheterna är många och begränsningarna få. Där barnen och ungdomarna inte upplever normer kring vad som är normalt, utan en plats där de får exprimentera och inte fastna i begrepp av vad som är rätt och fel. Att komma till Kulturskolan i Älvsjö ska ge eleverna känslan av den taklösa byggnaden som inte begränsar utan snarare visar på alla de möjligheter en plats för lärande och reativitet har. Byggnaden är en samlad kropp med rumsligheter i fasad. I kontrast till grannen Stockholmsmässan där all verksamhet sker i hemlighet och bakom slutna väggar visar byggnaden upp sin verksamhet för det kringliggande Älvsjö. Jag har sökt efter en byggnad där barnen får vara kvar i sin öppna värld. Där det inte finns ett rätt svar utan där svaren är många. Eleverna ska kunna vrida på huvudet och världen ska vara sig lik eller lägga sig på golvet och upp liknar ner. Det blir en byggnad utan tak eller ett fotavtryck mot himmlen. / Before I started studying architecture, I was a dancer for many years. I often laid on the floor and looked at the ceiling. For so long that the ceiling was transformed into a wall. I have also twisted and turned myself dizzy in rooms so boundaries have become blurred, where up has been down and down has been up. With that experience, I have been looking for a way to erase the limits of what is a wall, a floor and a ceiling. A Kulturskola should be a place for learning, desire and creativity. A place where the opportunities are many and the limitations are few. Where children and young people  not experience  norms of what is normal, but where they can experiment and not get caught up in the concept of what is right and wrong. Beeing at the Kulturskola in Älvsjö should give the students the feeling of the roofless building which does not limit but rather shows all the potential of a place for learning and creativity. In contrast to the neighboring Stockholm International Fairs where all the activity takes place in secret and behind closed walls, this buildning shows Älvsjö what is happening inside. I have searched for a building where children can be left in their open world. Students should be able to turn their heads and the world should be the same or lie down on the floor and up is similar to down. It is a building without a roof or a footprint to the sky.
3

UNDERSÖKNING AV EVENTUELLT SAMBAND MELLAN DIABETES MELLITUS OCH HÖGT BUKUPPTAG VID MYOKARDSCINTIGRAFI

Yousef, Widad January 2022 (has links)
Myokardscintigrafi är en nuklearmedicinsk metod som med hjälp av en radioaktivspårsubstans och bildtagning ger prognostisk information om hjärtats perfusionoch ventrikulära funktion. Förekomsten av artefakter i form av störandebukupptag i bilderna är ett välkänt problem vid myokardscintigrafi, då det kanskymma en del av vänsterkammarens inferiora vägg. Ett högt bukupptag kräverdärför ofta en upprepad bildtagning, vilket är besvärligt för den enskilde patientenoch påverkar klinikens patientflöde och arbetsbelastning negativt.Patienter som har diabetes mellitus diagnos utvecklar ofta neuropati vilket kan geen förlångsammad tarmrörelse. Denna patientgrupp skulle därför teoretiskt kunnatänkas ha högre sannolikhet för högt bukupptag jämfört med patienter utandiabetes mellitus diagnos.Syftet med denna studie var att se om sannolikheten för bildomtagning på grundav högt bukupptag vid undersökningen myokardscintigrafi är större hos patientermed diabetes mellitus än hos patienter utan diabetes mellitus.Studien inkluderade totalt 200 patienter som hade utfört myokardscintigrafi, vilkadelades in i två olika grupper. En grupp med diabetes mellitus diagnos n=100, ochen grupp utan diabetes mellitus n=100. Antalet patienter som behövt genomförabildomtagning p.g.a. högt bukupptag i båda grupperna kontrollerades. Enkorstabell samt Chitvåtest (χ²) och Fishers exakta test användes för att analyseraom det fanns en statistiskt signifikant skillnad mellan grupperna (p&lt; 0.05).Resultatet visade ingen statistisk signifikant skillnad mellan de två grupperna;Chitvåtest (χ²) (p=0.35) och Fishers exakta test (p=0.54). Slutsatsen blev att ingetsamband mellan diabetes mellitus diagnos och högt bukupptag vidmyokardscintigrafi kunde påvisas.
4

Framtagning av demonstratorer

Birkelöf, Jonas January 2009 (has links)
På Alfred Nobelmuseet i Karlskoga finns en avdelning som kallas Fiffiga huset. Där finns många experiment som besökare kan prova på, samt montrar som visar hur olika tekniska och maskinella apparater fungerar. Till utställningen och öppnandet sommaren 2009 ville de ha två nya demonstratorer. I rapporten kallas dem för reaktionstidsväggen och baklängesprataren. Reaktionstidsväggen skulle mäta besökarens reaktionstid genom att tryckknappar, med inbyggda dioder som slumpvis tänds, trycks ned i rätt ordning. Baklängesprataren skulle spela in besökarens tal och sedan spela upp det baklänges. Tanken var att besökaren skulle försöka prata baklänges och få det att låta rätt vid uppspelning. Arbetet gick ut på att bygga dessa demonstratorer och montera dem i Fiffiga huset. Reaktionstidsväggen styrdes med hjälp av en mikroprocessor ATMega16 från Atmel. Dess jobb var att läsa av knapptryckningar samt skicka information till dioder och display. Även baklängesprataren skulle styras med hjälp av mikroprocessorn ATMega16. En enkel mikrofonförstärkare samt filter till högtalarna skulle anslutas till processorn. Det inbyggda minnet skulle inte räcka till så ett extern minne behövde anslutas.Endast reaktionstidsväggen hann bli färdig inom projektets ramar eftersom all gammal elektronik som medföljde från Nobelmuseet var komplex, samt att många kortslutningar och avbrott gjorde felsökning till en tidskrävande procedur.
5

Projektering av odlingsvägg för inomhusbruk som bevattnas med uppsamlad nederbörd från byggnadens tak / Designing an interior wall for cultivation that is irrigated with pre-stored precipitation from the building's roof

Elsebti, Isabella, Ljungdal, Ida January 2013 (has links)
I takt med att klimathoten mot vår planet ökar raskt, ökar också människors egna engagemang för att lösa problematiken. I städerna finns det initiativ med målsättningen att skapa en bättre framtid för jorden än den som idag spås. Problem med överbelastade dagvattensystem och långa mattransporter i städerna är två klimathot som bl.a. kan avhjälpas med lokalt omhändertagande av dagvatten respektive stadsodling. Därför kommer följande rapport att avhandla hur det på bästa sätt kan utformas en odlingsvägg inomhus som tar hand om nederbördsvatten från byggnadens tak i projektet Haningeterrassen. För att lösa uppgiften har litteraturstudie, studiebesök och intervjuer varit underlag för arbetet som även har innehållit en fallstudie. Detta för att få en bättre inblick i hur hela väggen och systemet bör utformas för en specifik byggnad, i vårt fall ett hus i projektet Haningeterrassen. Målet med projekt har varit att ta fram ett förslag på en byggteknisk lösning på en grön vägg inomhus som kan hantera nederbörd m.h.a. planterade nyttoväxter exempelvis sallad, tomat och basilika. Där följande frågor har besvarats för den utvalda byggnaden i Haningeterrassen: Hur kan en grön vägg bli ett verktyg för människor att använda som en del i den hållbara staden? Hur utformas en grön vägg som bevattnas med nederbörden från byggnadens tak? Nyttoväxterna bidrar till stadens hållbara utveckling genom att minska mattransporter till staden för väggens brukare. Och utnyttjandet av nederbörd bidrar till stadens hållbara utveckling genom att minska belastningen på stadens dagvattensystem. Viktigt att poängtera är att denna vägg enbart är en förslagsskiss och en fortsättning på projektet är önskvärd. / Whilst the climate threat on earth increases, people’s own involvement in the issue increases with it. Several initiatives exist in the cities with the objective to create a better future for the earth than what is predicted today. Problems with overburdened stormwater systems and long transport distances for food are two of these climate threats that can be decreased with local management of stormwater respectively urban farming. Therefore the following report will examine the preferable way to create an interior wall for cultivation that is irrigated with pre-stored precipitation from the roof of a specific building in the project Haningeterrassen. For solving the task, literature studies, study visits and interviews have been the foundation for the work, which also have included a case study. This to get a better insight in how the whole system and a green wall should be designed for a specific building, in our case a house in the project Haningeterrassen. The goal with the project has been to form a proposal of a design solution of a green inner wall that can manage precipitation with planted culturing plants for example lettuce, tomato and basil. The following questions have been answered for the chosen building in Haningeterrassen: How can a green wall become a tool for the average person to use as a part of the sustainable city? How is a green wall best designed for managing the precipitation that lands on its building’s roof by being irrigated with it?  The culturing plants in the wall contribute to the city’s sustainable development by reducing long transport distances for food for the users of the wall. And the usage of precipitation contributes to the city’s sustainable development by reducing the burden on the city’s stormwater systems. It is important to acknowledge that this green wall only is a proposal sketch. A continuation of the project is desirable.
6

Urban Building vid Hornsbruksgatan : Två Sidor av Hornsbruksgatan

Sivesson, My January 2012 (has links)
Platsen för projektet är bergskanten mellan Hornsbruksgatan och Högalidsparken på Södermalm i Stockholm. Platsen präglas av en stark tvåsidighet, mellan gata och park, som jag valt att ta fasta på i mitt projekt även i programmet. Många vill bo i Stockholms innerstad men få är priviligerade att faktiskt kunna göra det och därför har det varit viktigt för mig att bygga effektiva bostäder där bostadsytan kan användas effektivt för att fler ska få plats att bo i staden. Jag har ritat fyra hus där studenter och familjer med föränderliga behov av bostadsyta kan leva i symbios. Detta tack vare sina olikheter med olika krav och önskningar på bostaden. På varje våning över parknivå finns tre lägenheter, två studentlägenheter och en större “villalägenhet”. Mellan de båda mindre studentlägenheterna och den större finns ett rum som tack vare skjutbara väggar kan tillhöra båda lägenheterna. De små hushållen kan, tack vare den korta hyrestiden på studentlägenheter, fungera som en buffertzon för de stora hushållen då dessa behöver mer eller mindre utrymme. Samtidigt möjliggör detta att fler studenter får möjlighet att bo i Stockholms innerstad.
7

RANS &amp; WMLES Simulations of Compressor Corner Separation

Poulain, Arthur January 2019 (has links)
In axial compressor, corner separation phenomenon can occur between the blade surface and the hub. This leads to high total pressure losses, blockage and may worsen to surge. Various studies on NACA65-009 blade were previously performed experimentally and numerically to predict the corner separation. The LMFA showed that RANS simulations tend to overestimate it while the Wall-Resolved LES (WRLES) was able to well capture it. The conclusions drawn on RANS are validated here with another solver software. An extensive parametric study is performed on RANS which highlights the good performance of two non-linear turbulence models k − ω Wilcox QCR and EARSM k − kl for for predicting the topology and the intensity of corner separation. They are however very dependent on the mesh and the numerics. A Wall-Modeled LES (WMLES) is then computed. It reproduces well the topology of the separation given by the experiments and predicts similar anisotropy to the WRLES. Nevertheless it shows high sensitivity to the level of turbulence close to the endwall and the boundary layer profile of the upstream flow. Finally, this confirms that the WMLES is a promising alternative to the WRLES in order to study the corner separation on more costly geometries (several blades for instance). / I axiell kompressor kan hörnseparationsfenomen uppstå mellan bladytan och navet. Konsekvenserna är stora totala tryckförluster och kompressor blockering. Olika studier på NACA65-009 bladet utfördes tidigare experimentellt och numeriskt för att förutsäga hörnseparationen. LMFA visade att RANS simuleringar tenderar att överskatta den hörnseparationen medan Vägg-Löst LES (WRLES på engelska) kunde fånga bra den. Slutsatserna som dras om RANS valideras här med en annan lösningsprogramvara. En omfattande parametrisk studie utförs på RANS som belyserde goda prestandan för två icke-linjära turbulensmodeller k − ω Wilcox QCRoch EARSM k − kl för att förutsäga topologin och intensiteten för hörnseparation. Dock är de mycket beroende av nät och numerik. En Vägg-Modell LES (WMLES på engelska) beräknas sedan. Det reproducerar väl topologin för separationen som ges av experimenten och förutsäger liknande anisotropi som WRLES. Dock visar det hög känslighet för turbulensnivån nära ändväggen och gränsskiktsprofilen för uppströmsflödet. Slutligen bekräftar detta att WMLES är ett lovande alternativ till WRLES för att studera hörnseparationen på dyrare geometrier (till exempelflera blad).
8

Abdominal aortic aneurysm inception and evolution - A computational model

Grytsan, Andrii January 2016 (has links)
Abdominal aortic aneurysm (AAA) is characterized by a bulge in the abdominal aorta. AAA development is mostly asymptomatic, but such a bulge may suddenly rupture, which is associated with a high mortality rate. Unfortunately, there is no medication that can prevent AAA from expanding or rupturing. Therefore, patients with detected AAA are monitored until treatment indication, such as maximum AAA diameter of 55 mm or expansion rate of 1 cm/year. Models of AAA development may help to understand the disease progression and to inform decision-making on a patient-specific basis. AAA growth and remodeling (G&amp;R) models are rather complex, and before the challenge is undertaken, sound clinical validation is required. In Paper A, an existing thick-walled model of growth and remodeling of one layer of an AAA slice has been extended to a two-layered model, which better reflects the layered structure of the vessel wall. A parameter study was performed to investigate the influence of mechanical properties and G&amp;R parameters of such a model on the aneurysm growth. In Paper B, the model from Paper A was extended to an organ level model of AAA growth. Furthermore, the model was incorporated into a Fluid-Solid-Growth (FSG) framework. A patient-specific geometry of the abdominal aorta is used to illustrate the model capabilities. In Paper C, the evolution of the patient-specific biomechanical characteristics of the AAA was investigated. Four patients with five to eight Computed Tomography-Angiography (CT-A) scans at different time points were analyzed. Several non-trivial statistical correlations were found between the analyzed parameters. In Paper D, the effect of different growth kinematics on AAA growth was investigated. The transverse isotropic in-thickness growth was the most suitable AAA growth assumption, while fully isotropic growth and transverse isotropic in-plane growth produced unrealistic results. In addition, modeling of the tissue volume change improved the wall thickness prediction, but still overestimated thinning of the wall during aneurysm expansion. / Bukaortaaneurysm (AAA) kännetecknas av en utbuktning hos aortaväggen i buken. Tillväxt av en AAA är oftast asymtomatisk, men en sådan utbuktning kan plö̈tsligt brista, vilket har hög dödlighet. Tyvärr finns det inga mediciner som kan förhindra AAA från att expandera eller brista. Patienter med upptä̈ckt AAA hålls därför under uppsikt tills operationskrav är uppnådda, såsom maximal AAA-diameter på 55 mm eller expansionstakt på 1 cm/år. Modeller för AAA-tillväxt kan bidra till att öka förståelsen för sjukdomsförloppet och till att förbättra beslutsunderlaget på en patientspecifik basis. AAA modeller för tillväxt och strukturförändring (G&amp;R) är ganska komplicerade och innan man tar sig an denna utmaning krävs de god klinisk validering. I Artikel A har en befintlig tjockväggig modell för tillväxt av ett skikt av en AAA-skiva utö̈kats till en två-skiktsmodell. Denna modell återspeglar bättre den skiktade strukturen hos kärlväggen. Genom en parameterstudie undersö̈ktes påverkan av mekaniska egenskaper och G&amp;R-parametrar hos en sådan modell för AAA-tillväxt. I Artikel B utvidgades modellen från Artikel A till en organnivå-modell för AAA-tillväxt. Vidare inkorporerades modellen i ett “Fluid–Solid–Growth” (FSG) ramverk. En patientspecifik geometri hos bukaortan användes för att illustrera möjligheterna med modellen. I Artikel C undersöktes utvecklingen av patientspecifika biomekaniska egenskaper hos AAA. Fyra patienter som skannats fem till åtta gånger med “Computed Tomography-Angiography” (CT-A) vid olika tillfällen analyserades. Flera icke triviala statistiska samband konstaterades mellan de analyserade parametrarna. I Artikel D undersöktes effekten av olika tillväxt-kinematik för AAA tillväxt. En modell med transversellt-isotrop-i-tjockleken-tillväxt var den bäst lämpade för AAA tillväxt, medans antagandet om fullt-isotrop-tillväxt och transversellt-isotrop-i-planet-tillväxt producerade orimliga resultat. Dessutom gav modellering av vävnadsvolymsförändring ett förbättrat väggtjockleks resultat men en fortsatt överskattning av väggförtunningen under AAA-expansionen. / <p>QC 20161201</p>
9

Effektivisering vid montering av KL-element – en pilotstudie av infästningar mellan väggskiva- bjälklagsplatta / More effective installation of CLT-elements – a pilot study on connections of wall-to-floor joints.

Finnhult, Johan, Petersson, Martin January 2020 (has links)
Byggsektorn tenderar idag att välja material med låg miljöpåverkan och bygga energi- och tidseffektiva konstruktioner. Att öka användningen av träprodukter är en del av lösningen. Korslimmat trä (KL-trä) är ett byggmaterial som har blivit mer och mer populärt att använda i byggbranschen. I Sverige har KL-trä använts sedan slutet på 90- talet och användandet ökar för varje år som går. Materialet är relativt nytt och vid monteringen av KL-trä finns det utrymme för förbättringar. Syftet med arbetet är att undersöka och analysera hur dagens infästning av KL-element utförs och hur dessa kan effektiviseras. Målet är att undersöka om det går att korta ner monteringstiden av KL- trästommar. Detta görs genom beräkningar, fältstudie och experiment. I arbetet undersöks möjligheten att reducera skruvning för det vanligast använda vägg till golv anslutningarna och om det finns tid att spara i montaget med hjälp av förborrning. Resultatet av rapporten visar att det finns en potentiell tid motsvarande ca 40 % tidsvinst att spara med förborrade bjälklag från fabrik och andra kvalitétsfördelar som förborrning kan medföra, medan reducering av skruv är möjligt men inte optimerad för dagens mest tillämpade infästningslösningar. / The construction sector today tends to choose material with a low environmental impact and build energy- and time-efficient structures. Increasing the use of wood products is part of the solution. Cross laminated timber (CLT) is a building material that has become more and more popular to use in the construction industry. In Sweden, CLT has been used since the late 90 and its use is increasing every year. The material is relatively new and especially for mounting CLT element, there are still potentials for improvement. The purpose of the work is to investigate and analyze how todays attachment of CLT elements is carried out and how these can be made more efficient. The aim is to investigate whether it is possible to shorten the assembly time of CLT elements. The study was carried out through calculations, study visit and experiments. The work investigates the possibility of reducing screwing for the most commonly used wall to floor joints and showed there is a potential time efficiency of about 40% to be gained with pre-drilled floor element from the factory and other quality benefits that pre-drilling can bring, while the study also showed reducing fasteners under construction phase is possible but not an optimal solution.
10

Bucklingsanalys av spannmålssilo / Buckling analysis of grain silo

Calestam, Magnus, Wedin, Johan January 2013 (has links)
Spannmål med varierande fuktighetsgrad kan lagras i kvadratiska silor med väggelement bestående av korrugerad plåt. Då det lagrade spannmålet ska tömmas har det fuktiga spannmålet en tendens att fastna på väggarna, vilket medför att spannmålet i efterhand måste avlägsnas manuellt. För att slippa denna tidskrävande process monteras en slät plåt på den korrugerade plåten, för att på så vis hindra det fuktiga spannmålet från att fastna. Om samma plåtdimensioner för den korrugerade plåten används då den släta plåten är och inte är monterad kan väggelementen utsättas för buckling. Det här examensarbetet handlar således om hur väggelementen ska dimensioneras för att strukturen inte ska utsättas för buckling. De silor som undersöks har tvärsnitten 3,0 x 3,0 m och 2,5 x 2,5 m med väggelement som består av endast korrugerad plåt samt med slät plåt monterad på korrugerad plåt. Vidare har silorna vertikala väggar med höjden 8,4 m som består av tio sektioner. Beräkningar har utförts då fyllnadsmaterialet är vete.   För att väggelementen ska kunna dimensioneras beräknas vilka trycksituationer som uppstår i de olika silorna med hjälp av den svenska och europeiska standarden Eurokod (2006), EN 1991-4 för tryckberäkningar i silor och behållare. För att beräkna trycksituationerna delas de aktuella silorna in i åtgärdsklass 1 då deras kapacitet understiger 100 ton, vilket innebär att osymmetriska tryck kan ignoreras. Silorna klassas även som slanka. Då silornas utlopp består av en pyramidformad tratt med centriskt utlopp och då trattens halva inre vinkel är 45° uppstår ett inre rörflöde vid tömning. Detta medför enligt Eurokod att silorna ska dimensioneras enligt trycken som uppstår vid fyllning. Det horisontella och vertikala trycket samt trycket som uppstår från friktionen beräknas för de olika tvärsnitten.   CAD-programmet Pro Engineer och finita elementtillägget Mechanica används för att modellera de aktuella silorna och utföra analyser med avseende på spänning och buckling. Modellerna har fyra symmetriplan, därför modelleras endast en åttondel av de aktuella strukturerna. Detta motsvarar ett halvt väggelement och en halv stolpe. Modellerna skapas som skalmodeller och randvillkor ansätts i alla snittytor samt på stolpens över och underkant. I modellerna förenklas strukturen genom att inga skruvar eller radier modelleras. Trycken framräknade enligt Eurokod räknas om till krafter och appliceras på modellerna. Hela strukturen modelleras i stål med sträckgränsen 180 MPa.   En av företagets äldre dimensioneringsstandarder undersöks genom att väggelementen tilldelas plåttjocklekar enligt denna. För att undersöka var de mest kritiska områdena för buckling uppstår utförs en bucklingsanalys grundad på en statisk analys för modellerna. Resultatet från bucklingsanalysen för silon med väggelement bestående av korrugerad plåt med väggbredden 3,0 m visar att buckling uppstår på den näst nedersta sektionen vid 72 % av den applicerade kraftresultanten. För silon med samma väggelement fast med bredden 2,5 m uppstår buckling på den översta sektionen där bucklingskraften uppgår till 62 % av den applicerade kraftresultanten. För silorna med väggelement bestående av slät plåt monterad på korrugerad plåt uppstår buckling redan vid 3-4 % av den applicerade kraftresultanten, för båda väggbredderna. Då det genom analyser framkommit att det är lokala bucklingar enbart på den släta plåten som ger dessa låga värden friläggs den korrugerade plåten för att trycksituationen som verkar från den släta plåten på så vis ska kunna erhållas. Med kraften från den släta väggen kan den korrugerade plåten därmed dimensioneras mot buckling. Vid bucklingsanalys av den korrugerade plåten som är tryckbelastad av den släta plåten framgår att buckling då väggbredden är 3,0 m uppstår på silons näst understa sektion. Bucklingskraften uppgår till 59 % av den applicerade kraftresultanten. För silon med väggbredden 2,5 m uppstår buckling vid 51 % av den applicerade kraftresultanten på silons översta sektion.   Då målet är att de korrugerade plåtarna inte får utsättas för buckling provas plåttjocklekar fram i finita elementmodellerna tills att bucklingskraften uppgår till minst 110 % av den applicerade kraftresultanten. Detta genererar att plåttjocklekarna för de nedre fyra sektionerna av väggelementen bestående av korrugerad plåt med bredden 3,0 m behöver ökas. För silon med samma väggelement fast med väggbredden 2,5 m behöver dimensionen på de två översta sektionerna ökas. För silorna med väggelement bestående av slät plåt monterad på korrugerad plåt behöver den korrugerade plåten för väggbredden 3,0 m ökas för de fem understa sektionerna medan samma dimensioner för väggbredden 2,5 m kan användas som för silon med väggelement bestående av enbart korrugerad plåt. Om den släta plåten inte får utsättas för buckling behöver plåttjocklekarna ökas från mellan 5,5 mm och 1,5 mm. Vid beräkningar av plåtdimensioner har ett konservativ förfarande använts vilket innebär att företagets dimensionering kan vara korrekt. Erhållna dimensioneringsförslag är emellertid rimliga för de korrugerade plåtarna. / Grains with varying humidity can be stored in square silos with wall elements consisting of corrugated sheet. When the stored grain is to be emptied from the silos it has tendency to stick to the walls, especially if humid, which means that the grain must be removed manually. To avoid this time-consuming process a flat sheet is mounted on the corrugated sheet to prevent the moist grain from sticking to the wall. If the same dimension on the corrugated sheet is used when the flat sheet is or is not mounted the walls may be subjected to buckling. This thesis is thus about how the wall elements shall be designed in order to prevent buckling. The silos that have been examined have a cross section of 3.0 x 3.0 m and 2.5 x 2.5 m respectively with wall elements consisting of only corrugated sheet or smooth sheet mounted on corrugated sheet. Furthermore, the silos got vertical walls with a height of 8.4 m consisting of ten sections. Calculations are made with wheat as the stored grain.   To be able to dimension the wall elements the pressure is calculated for the different silos, using the Swedish and European standard Eurocode (2006), EN 1991-4 for pressure calculations in silos and tanks. To calculate the pressure the silos are assigned into action assessment class 1, since their capacity are less than a 100 tons, which further means that the unsymmetrical pressure can be ignored. The silos are also classified as slender. As the silos outlet consists of a square pyramidal hopper with centric outlet and a half internal angel of 45° an inner pipe flow occurs during emptying. This means according to Eurocode that the dimension shall be based on the pressure which occurs during filling. The horizontal and vertical pressure and the pressure made from the friction are calculated for the different cross sections.   The CAD software Pro Engineer and the finite element extension Mechanica is used to model the current silos and perform analysis for stress and buckling. The models have four symmetry planes therefore only one eighth of the current structure is modeled, corresponding to half a wall element and half a pole. The models are created as shell models and boundary conditions are applied in all symmetrical planes and on the top and bottom of the pole. The structure of the silos is simplified since no screws or radius is modeled. The pressure calculated according to Eurocode is converted into forces and applied to the models. The whole structure is modeled in steel with yield strength of 180 MPa.   The company’s older dimension standards are applied on the wall elements and analyzed. To investigate where to most critical areas for buckling occurs a buckling analysis based on a static analysis of the models is performed. The results from the buckling analysis for the silo wall element consisting of corrugated sheet with the width of 3.0 m shows that buckling occurs on the second bottom section at 72 % of the applied force. For the silo consisting of the same wall element but with the width of 2.5 m buckling occurs at the top section where the buckling force amounts to 62 % of the applied force. For the silos with wall elements consisting of plain sheet mounted on corrugated sheet buckling occurs at 3-4 % of the applied force for the two wall widths. Analysis show that the low values of buckling load on the plane sheet is a result from local buckling. In order to dimension the corrugated sheet to prevent it from buckling when the plane sheet is mounted a free body diagram is made for the corrugated sheet to obtain the acting forces. The buckling analysis of the corrugated sheet, with wall width 3.0 m, which is pressurized by the plane sheet shows that buckling occurs on the silos second bottom section. Buckling occurs at 59 % of the applied force for the silo with wall width of 2.5 m buckling occurs at 51 % of the applied force on the silo top section.   Since the goal is that the corrugated sheets are not to be subject to buckling, the thickness of the sheets is iterated until the buckling force is equal to at least 110 % of the applied force. This generates an increased thickness for the lower four sections for the silo with wall element consisting of corrugated sheet with wall width of 3.0 m. For the silo with the same wall elements but with a wall width of 2.5 m, the dimensions of the top two sections need to increase. Regarding the silos with wall elements consisting of plane sheet mounted on corrugated sheet an increase in dimension is needed for the corrugated sheet for the five lowest sections for the wall width of 3.0 m.   With a wall width of 2.5 m the same dimension can be used as when the silo wall elements consist of only corrugated sheet. If the plane sheet is not to be exposed for buckling the thickness of the sheets needs to be increased from between 5.5 mm and 1.5 mm. All calculations of the sheet dimensions are obtained by a conservative thinking which means that the company’s older dimensions may be correct. However, the resulting dimensions are reasonable for the corrugated sheets.

Page generated in 0.0479 seconds