Spelling suggestions: "subject:"cross aminated timber"" "subject:"cross iaminated timber""
91 |
A techno-economic case study of external timber wall assemblies in Swedish single-family homesMaad, Deaa, Alkhen, Mohamad Feras January 2021 (has links)
Decisions made at the early stage of building design can significantly influence theenvironmental, energy and economic performance of buildings. Future homeowners anddevelopers often have to make decisions concerning the design and specification of thebuilding. These choices are usually governed by functionality, aesthetics, cost, materialavailability, etc. Except for decisions related to long-term performances, they are relativelyeasy and straightforward to make. Long-term performance assessments that consider theimpact of a product over its lifetime, requires thorough research. Due to the lack of studies onthe long-term benefits and performance of different building design options, homeowners anddevelopers often base their decisions on short-term financial benefits, ignoring long-termbenefits. This may lead to incorrect decisions that are difficult to correct.Within this context, the aim of this study is to compare the long-term economic viability ofdifferent external timber wall construction types. By doing so, our goal is to address the lackof techno-economic studies within the construction industry and thus, to assist the decisionmakingof Swedish homeowners and developers. We evaluate the economic performance ofthree wooden wall construction alternatives—that of IsoTimber, cross-laminated timber(CLT), and timber frame walls—via thirteen wall assembly scenarios and two case housesfrom Bysjöstrand eco-village, Sweden. The scenarios account for variations in wall type andwall thicknesses. Our study utilizes an approach based on life cycle costing (LCC) andconsiders the capital cost and the present value of heating cost. The latter is calculated for 1m2of heated area of each case houses over a 40-year period. Indoor Climate and Energy software(IDA ICE) is used to estimate the heating energy use and the Bidcon program to estimate thematerials and labor costs for all cases. The study considered reasonable economic parameters,but to see their impact on the results and feasibility of wall constructions improving, sensitiveanalysis has been done using different values.The main finding of this thesis is that timber frame wall construction is the most economicchoice in the long term. In contrast, IsoTimber wall is the least economic choice, in general,and for two-story homes, in particular. Moreover, the present value total cost for IsoTimber intwo-story building is 5% higher than for a single-story building that has a similar U-value. Incontrast, it is 3% and 7% lower for CLT and timber frame walls respectively. Also, the resultsindicate that although the present value heating cost decreases with increasing wall thickness,this increase is considerably smaller than the increase in the capital cost. Finally, assumedeconomic factors affect the results greatly, but in general, improving the U-value of CLT wallconstruction might be the most profitable then timber frame comes after, and then IsoTimbercomes in the last. Along with, return economic benefit from the improvement of all studiedwall constructions in single-story building is higher than the benefit in two-story building.
|
92 |
Brand i träkonstruktioner : En studie om brandförlopp i olika slags konstruktioner i träBerg, Elis January 2021 (has links)
Det byggs i trä i Sverige som aldrig förr. Det blir alltmer populärt för varje år som går att ersätta prefabricerade element i betong samt pelare och balkar i stål med element med motsvarande funktion i antingen korslimmat trä eller limträ. Under tidsperioden 2010 till och med 2019 har andelen nyproducerade lägenheter i flerbostadshus, som byggts i trä, ökat med 122 %. Det kommer delvis som en följd att det först 1994 blev tillåtet att bygga flervåningshus i trä när funktionskrav infördes. Vid byggande i trä finns det olika sorters trämaterial att välja mellan, tre av dem är konstruktionsvirke, limträ och korslimmat trä. Konstruktionsvirke är ursågade delar av trädstammar och limträ samt korslimmat trä är sammansatta trämaterial av konstruktionsvirke i form av lameller och lim. Skillnaden mellan limträ och korslimmat trä är att lamellerna, lagren, är lagda i samma riktning i limträ och som namnet antyder, korsvis i korslimmat trä. Limträ har formen av pelare och balkar medan korslimmat trä bildar massiva skivelement. Eftersom trä är ett organiskt material kommer det vid hög temperatur att antända och förbrännas. Syftet med uppsatsen är att undersöka huruvida brandförloppet skiljer sig mellan konstruktionsvirke, limträ och korslimmat trä samt ta reda på om limmet påverkar brandförloppet eller inte i fallen med limträ och korslimmat trä. Uppsatsen är av det kvalitativa slaget, och analyserar därmed redan framtagen information snarare än tillföra egen. Informationen hämtas från intervjuer med personer med för uppsatsen relevanta kompetenser och från litteraturstudier. Eftersom alla tre i uppsatsen analyserade material består av eller är konstruktionsvirke kommer brandförloppen i stora drag vara jämförbara. Lamelleringseffekten i limträ och korslimmat trä kommer göra brandförloppen i de materialen mer gynnsamma. Den stora skillnaden i brandförlopp kommer bero på huruvida det ingående limmet i limträ och korslimmat trä delaminerar vid upphettning. Det finns flera olika sorters lim tillåtna för ändamålet, där vissa sorter delaminerar och andra inte. Uppsatsens slutsats är att materialen som tidigare nämnts i stort genomgår samma brandförlopp och att valet av lim kommer ha påverkan på brandförloppet då eventuell delaminering är ogynnsamt för konstruktionen. / In Sweden, building with wood have never been so popular as now and to exchange prefabricated elements in concrete and pillars and beams in steel with corresponding elements in either cross-laminated timber and or glued-laminated timber becomes increasingly more popular on a yearly basis. During the timeframe from 2010 through 2019 the share of newly produced flats in multi-storey buildings have risen with 122 %. In part, it can be explained by the introduction of function-based design in Sweden 1994, before that, wooden multi-storey buildings were not allowed. When building with wood, there are several wooden materials to choose from, three of which are dimensional lumber, glued-laminated timber, and cross-laminated timber. Dimensional lumber is sawed parts of logs and glued-laminated timber and cross-laminated timber are engineered wood composed by dimensional lumber in form of laminating stock and adhesives. The difference between glued-laminated timber and cross-laminated timber are that the laminating stock, the layers, are oriented the same way in glued-laminating lumber and as the name suggests, crossed, perpendicular to each other in cross-laminated timber. Glued-laminated timber is used as pillars and beams while cross-laminated timber is used as massive wooden panels. Since wood is an organic material, it will ignite and combust at high temperatures. The purpose of the thesis is to examinate whether the fire course differs in dimensional lumber, glued-laminated timber, and cross-laminated timber. The thesis is qualitative, and therefore analyses already researched information rather than providing new. The information is provided by interviews with people with relevant functions according to the thesis and from literary studies. As all three materials analysed in the thesis are composed of or are dimensional lumber the fire course will broadly be comparable, however, the in glued-laminated timber and cross-laminated timber inherent laminating effect will make these materials fire course more advantageous. The main divergence in fire course will depend on whether the in glued-laminated timber and cross-laminated timber inherent adhesive will delaminate when heated or not. There are several different types of adhesives allowed for the purpose where some types will delaminate and other will not when heated. The conclusion of the thesis is that the earlier mentioned materials broadly experience the same fire course, and that the choice of adhesive will have effect on the fire course due to eventual delamination being disadvantageous for the construction. / <p>Betyg 2021-06-04</p>
|
93 |
Ekonomisk jämförelse av prefabricerad betong och korslimmat trä-Totalkostnad av materialen i stommarna / Economical comparison of concrete and cross laminated timber- Total costs of material in the building frameBerglund, Martin January 2021 (has links)
Byggbranschen i sverige har ett mål att till 2045 uppnå noll nettoutsläpp av växthusgaser. I dagsläget såbyggs det vid större byggnationer mestadels med betongstomme, vilket har en hög koldioxidutsläpp vidnyproduktion. Detta medför att miljömålen inte kommer uppnås om inte andra alternativ tillbyggnadsmaterial börjar användas i större utsträckning. Det material som är bäst alternativ till betong iflerbostadshus är KL-trä tack vare dess hållfasthet förmåga jämfört med vanligt trä. Problemet medKL-trä är att det har en så pass mycket dyrare produktionskostnad, att det fortsätter väljas betongstommari flerbostadshus. Om byggbranschen skall ha någon chans att klara kraven som ställts för år 2045 mednoll nettoutsläpp av växthusgaser så måste kostnaden för KL-trä alltså dras ner, för att dess användningska påskyndas. Syftet med denna studie är att ta fram den exakta totalkostnads skillnaden mellan enprefabricerad betongstomme och en KL-trästomme, samtidigt som byggnadsarean och struktur påstommarna är så lika som möjligt. Målet var att bevisa hur långt KL-träet har kvar till att konkurrera medbetong i flerbostadshus ekonomiskt.För att göra jämförelsen så togs en referensbyggnad fram som redan var utförd i betong, som sedandimensioneras om till KL-trä för en rättvis jämförelse. Dimensioneringen skedde genom lastsummeringgjord förhand. Dessa laster används sedan i ett beräkningsprogram för varje konstruktionsdel i Calculatissom tar fram de dimensioner som krävs för att klara hållfasthets kraven. Med ny dimensioneradträstomme, togs två materiallistor fram för de olika stommarna och jämfördes i kalkylprogrammet Bidconför en få fram en totalkostnads differens. Denna studie har fokuserat på att jämföra kostnaderna förstomme materialen för en byggnad i KL-trä och en i prefab betong. Icke bärande väggar, takkonstruktionsamt husunderbyggnad tillhör inte stommen, och kommer därmed inte att jämföras.Studien gav ett resultat som visade att det är cirka 42% dyrare att bygga med en KL-trä stomme än enprefabricerad betongstomme i ett flerbostadshus. Mellanbjälklaget är den dyrare komponenten, medansexempelvis andra delar som balkong och bärande vägg ändå visar sig vara billigare. Enligt BBR måstesärskilda ljud och brandkrav uppfyllas i lägenhetshus. För att uppnå dessa så behöver det läggas tillljudisolering i de KL-element som är lägenhetsavskiljande och brandgipsskivor i hela stommen medKL-trä. Detta leder till att KL-trä stommen generellt får en större tjocklek jämfört med betongstommenoch även lite extra kostnader att ha i åtanke, även då det bärande materialet är mindre i KL-trä stommen.Detta leder då till att lägenheternas boarea i KL-trä byggnaden blir något mindre än i betong byggnaden.Slutsatsen är att KL-trä inte är ett ekonomiskt alternativ till prefab betong enligt Bidcons databaser närdenna studien genomförts och är 42% dyrare tack vare att mellanbjälklaget har så hög kostnad. / The construction industry in Sweden has a goal of achieving zero net emissions of greenhouse gases by2045. At present, larger constructions are mostly built with a concrete frame, which has a high carbondioxide emission during new production. This means that the environmental goals will not be achievedunless other alternative building materials are being used to a greater extent. The material that is the bestalternative to concrete in apartment buildings is cross laminated timber (CLT), due to its durabilitycompared to regular timber. The problem with CLT is that it has such a much more expensive productioncost, that concrete frames continue to be chosen in apartment buildings. If the construction industry is tohave any chance of meeting the requirements set for the year 2045 with zero net emissions of greenhousegases, the cost of CLT must therefore be reduced in order for its use to be accelerated. The purpose of thisstudy is to produce the exact total cost difference between a prefabricated concrete frame and a CLTframe, while at the same time the building area and structure of the frames are as similar as possible. Thegoal was to prove how far the CLT has financially, until it can compete with concrete in apartmentbuildings.To make the comparison, a reference building was developed out of concrete, which is laterredimensioned to CLT for a fair comparison. The dimensioning was done by summarizing all loads byhand. These loads were later used for every part in the frame, in the calculation program Calculatis to getthe dimensions required for the demands on durability. With a new dimensioned wooden frame, twomaterial lists were produced for the different frames and compared in the Bidcon calculation program toobtain a total cost difference. This study has focused on comparing the costs of frame materials for abuilding in CLTand one in prefabricated concrete. Non-load-bearing walls, roof construction and groundstructure do not belong in the frame, and will therefore not be in the comparison.The study gave a result that showed that it is about 42% more expensive to build with a CLT frame than aprefabricated concrete frame in a 7 storey apartment building. The floor is the more expensivecomponent, while for example other parts such as balconies and load-bearing walls still proved to becheaper. According to BBR, special noise and fire requirements must be met in apartment buildings. Toachieve these, some sound insulation needs to be added to the CLT elements that are apartment separatorsand fire plasterboards in the entire frame with CLT. This leads to the CLT frame generally having agreater thickness compared to the concrete frame and also a few extra costs to keep in mind, even whenthe load-bearing material is smaller in the CLT frame. This leads to the living space of the apartments inthe CLT building being slightly smaller than in the concrete building. The conclusion is that CLT is not aneconomical alternative to prefabricated concrete according to Bidcon's databases when this study wascarried out and is 42% more expensive due to the fact that the intermediate floor has such a high cost.
|
94 |
Full life cycle assessment of a cross laminated timber modular building in SwedenAl-Najjar, Ahmad January 2021 (has links)
Building industry contributes to massive amounts of harmful emissions. This trend will continue to rise unless appropriate measures are taken. This master thesis aims to calculate the environmental impact during the whole life time of a prefabricated cross-laminated timber (CLT) modular building. The environmental impacts from the end-of-life stage and the benefit of the most of the building material beyond the system boundary is also included. Life cycle assessment (LCA) is used as a tool to assess the environmental impacts following the standard SS-EN 15978:2011. Since there is a lack of environmental data about CLT in general and about prefabricated CLT volumetric modules buildings in particular the results from this work will enhance the understanding of the environmental performance of this kind of building system. This work is done with Size AB, a company that only produces CLT modular multi-storeys buildings. The studied object is three storeys building located in Nykvarn in Sweden. The total emissions during the building life cycle are at least 377 kg CO2-eq/m2 of the gross floor area (GFA), 0,296 kg PO43--eq/m2 of GFA and 1,1 kg SO2-eq/m2 of GFA for global warming potential (GWP), eutrophication potential (EP) and acidification potential (AP) respectively. The result shows that the share of the AP and EP during the end-of-life stage is only 1% for each, whereas CO2-eq emission is accounted for 14% during this stage. The material production stage accounts for more than 50% for all environmental indicators. This study provides fundamental data to perform LCAs in this area and to carry out climate declarations. Through sensitivity analysis it was discovered inter alia that high production intensity in the modules fabrication factory plays a significant role in reducing the environmental impacts during the construction stage. It was also found that modification of the LCA’s system boundary is recommended to present a transparent LCA of modular buildings.
|
95 |
Performance-Based Engineering for Resilient and Sustainable Structures of the FutureSalgado, Rafael de Amorim January 2020 (has links)
No description available.
|
96 |
Effektivisering vid montering av KL-element – en pilotstudie av infästningar mellan väggskiva- bjälklagsplatta / More effective installation of CLT-elements – a pilot study on connections of wall-to-floor joints.Finnhult, Johan, Petersson, Martin January 2020 (has links)
Byggsektorn tenderar idag att välja material med låg miljöpåverkan och bygga energi- och tidseffektiva konstruktioner. Att öka användningen av träprodukter är en del av lösningen. Korslimmat trä (KL-trä) är ett byggmaterial som har blivit mer och mer populärt att använda i byggbranschen. I Sverige har KL-trä använts sedan slutet på 90- talet och användandet ökar för varje år som går. Materialet är relativt nytt och vid monteringen av KL-trä finns det utrymme för förbättringar. Syftet med arbetet är att undersöka och analysera hur dagens infästning av KL-element utförs och hur dessa kan effektiviseras. Målet är att undersöka om det går att korta ner monteringstiden av KL- trästommar. Detta görs genom beräkningar, fältstudie och experiment. I arbetet undersöks möjligheten att reducera skruvning för det vanligast använda vägg till golv anslutningarna och om det finns tid att spara i montaget med hjälp av förborrning. Resultatet av rapporten visar att det finns en potentiell tid motsvarande ca 40 % tidsvinst att spara med förborrade bjälklag från fabrik och andra kvalitétsfördelar som förborrning kan medföra, medan reducering av skruv är möjligt men inte optimerad för dagens mest tillämpade infästningslösningar. / The construction sector today tends to choose material with a low environmental impact and build energy- and time-efficient structures. Increasing the use of wood products is part of the solution. Cross laminated timber (CLT) is a building material that has become more and more popular to use in the construction industry. In Sweden, CLT has been used since the late 90 and its use is increasing every year. The material is relatively new and especially for mounting CLT element, there are still potentials for improvement. The purpose of the work is to investigate and analyze how todays attachment of CLT elements is carried out and how these can be made more efficient. The aim is to investigate whether it is possible to shorten the assembly time of CLT elements. The study was carried out through calculations, study visit and experiments. The work investigates the possibility of reducing screwing for the most commonly used wall to floor joints and showed there is a potential time efficiency of about 40% to be gained with pre-drilled floor element from the factory and other quality benefits that pre-drilling can bring, while the study also showed reducing fasteners under construction phase is possible but not an optimal solution.
|
97 |
Horečky / HorečkyPotůčková, Kristýna January 2018 (has links)
The matter of the Horečky project is complex called Art in Horečky,which is complex strategy how to get the people interested in arts to the area. Project designs gallery, house for artist, artistic path in nature...
|
98 |
Horský hotel v Králíkách / Mountain hotel in KrálíkyHoffmannová, Zdislava Unknown Date (has links)
The subject of this thesis was a structural design of a timber structure of a mountain hotel in Králíky. The object was a three storey building in a shape of letter U. The project was made in two different variations. The first one consisted of timber frame system with walls securing spacial stability. Computational model was created as a spacial bar 3D model in SCIA Engineer 19.1. The internal forces were calculated using the linear static analysis. The loadbearing structure was designed according to ultimate and serviceability limit states in SCIA Engineer 19.1. The thesis includes joints and anchorage design according to valid standards. Glue laminated timber was chosen as a material for the loadbearing structure while solid timber was chosen for wall structures. The second variation was made out of cross laminated panels. Wall panels were calculated by hand calculation whereas floor and roof panels were calculated using Agrop Nova Element software. Spatial model was made in SCIA Engineer 19.1 software to design joints and for global deformation check as well. The thesis includes engineering report, structural design report as well as drawings.
|
99 |
UTREDNING OCH UTFORMNING AV BALKONG I KL-TRÄ .Som är fuktsäker och går att utföra praktiskt.Eriksson, Emil, Moberg, Mattias January 2022 (has links)
L-trä har på kort tid blivit en vanligare byggmetod. Detta har medfört att det underlag som finns för projektering inom området inte är lika väl utvecklade som andra stomsystem. De lösningar som finns inom KL-trä, är idag ofta projektbaserade och är inte är helt genomtänkta ur alla aspekter. Från hur en prefabricerad betongstomme projekteras fram kan vissa principer tillämpas till KL-trä, men då detta är en annan typ av stomme blir vissa lösningar mer specifika mot KL-trä. Syftet med vår studie är att ta fram en balkonglösning som är fuktsäker och utveckla en standardiserad lösning som går att tillämpa praktiskt. Den ska även uppfylla de krav som regelverken ställer för en balkong. I rapporten används kvalitativa metoder som metodik. Litteraturstudier har använts för att ge en analys av det arbete som finns inom området idag. Datainsamling utfördes med Tom Noremo, som ligger till grund för intervjuer. Intervjuer utfördes med 11 sakkunniga med olika erfarenheter inom byggbranschen. Studien avgränsas till utanpåliggande balkonger infästa med dragstag. Även fasadsystemen avgränsas till Rockwools REDair alternativt PAROC:s ZERO. Den detalj som tas fram är enbart för bostadshus och ska klara av de tillgänglighetskrav som en balkong ska uppfylla. Inga beräkningar för bärförmåga har utförts och redovisad lösning utgår ifrån en befintlig lösning. Från litteraturstudierna och intervjuerna har en detalj för en balkong i KL-trä projekterats fram. Lösningen har liknande infästning som den detalj rapporten utgår ifrån. Resultatet blev att stålramen med UPE-profil som ligger runt om KL-skivan ska bytas ut mot en L-profil och infästning av dragstag ska sitta i sidorna. Balkonger i KL-trä ska ha hålkäl likt de som en prefabricerad betongbalkong har och ska dras hela vägen till framkant. Balkongerna ska utföras med en tralluppbyggnad som gör det enkelt att klara av tillgänglighetskraven och ger en mer fuktsäker konstruktion. Det tätskikt som monteras måste klara av den mekaniska åverkan som kommer från trallen, närmast dörrtröskel ska brädor bytas ut mot gallerdurk. För de balkonger som är extra utsatta för nederbörd kan en sockeluppbyggnad utföras. Slutsatsen blev att det krävs omfattande åtgärder för att en balkong i KL-trä ska bli lika hållbar som en betongbalkong. Materialval och arbetsutförande har en stor inverkan på slutresultatet. Studien har resulterat i ett gediget projekteringsunderlag för utformning av balkonger. / CLT is becoming a more popular building method. Therefore, the design documentation for CLT is not as developed as other frame systems. The solutions that exist today are only project-based and not always as well thought out as compared to how prefabricated concrete systems is designed. Some principles can be applied to CLT but since this is a different type of material the solutions need to become more specific to CLT. The purpose with our study is to develop a standardized balcony detail in CLT which is moisture-proof and can be applied in practice. It must also meet the requirements and regulations for a balcony set by the authorities. The report uses qualitative methods as a methodology to analyse the work that exist today for a balcony in CLT. We used literature studies and conducted 11 interviews with experts obtained from Kåver & Mellin. The study is limited to wall-mounted balconies attached with tension rods. The facade systems are limited to Rockwool´s RED air or PAROC zero. The detail in the report is only for apartment buildings and will meet the requirements set for a balcony. No calculations for load bearing capacity have been conducted where the solution is based on an existing solution. As a result, from the literature studies and interviews, a balcony detail in CLT has been projected. The detail uses similar attachments as the detail the report is based on. The result from the methodology was that the steel frame that is applied around the CLT-panel must be replaced with a L shaped steel frame. The attachments for the tension rods must be placed on the sides of the balcony. Balconies in CLT must have the same triangle formed element as prefabricated concrete balconies has and be drawn all the way to the front edge of the CLT-panel. The balconies need to be made with duckboard which makes it easier to meet the requirements of accessibility and provides a more moisture-proof construction. The waterproof layer needs to be able to withstand the load bearing coming from duckboard. The boards closest to the threshold can be replaced with a floor grate. The balconies that is extra exposed to bad weather can have an extra outer wall construction. The conclusion is that a balcony in CLT need extensive measures for it to become as durable as concrete balconies. Material selection and the work performance have the biggest impact on the result. The study has resulted in a solid design documentation for a balcony in CLT and an alternative solution has been produced which is moisture-proof and can be applied in practice.
|
100 |
Field durability test of CLT wall envelope using physical barriers against termites and structural performance of nailed hold-down brackets connected to fungus-exposed CLT wallsNeupane, Kamal 10 December 2021 (has links) (PDF)
The effectiveness of using commercial polyethylene flashing and stainless-steel mesh in CLT wall systems as the termite barriers were evaluated in a short-term field test. American Wood Protection Association (AWPA) E21's visual ratings ranged from 10 to 9 in the specimens showing little damage when no physical barriers were used. Termites were able to crawl beyond the physical barriers in few specimens showing the necessity of further research on height and installation method of physical barriers. On the second part, the effect of decay caused due to Postia placenta, a brown-rot fungus, on the structural performance of hold-down brackets connected to CLT walls was evaluated using monotonic and cyclic loadings. An increase in moisture content reduced the strength of the connection system but increased the initial stiffness. Decay caused delamination of CLT laminate perpendicular to the grain, a different failure pattern, compared to the wet control and dry control specimens.
|
Page generated in 0.0942 seconds