• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 131
  • 6
  • Tagged with
  • 137
  • 58
  • 48
  • 35
  • 34
  • 30
  • 27
  • 26
  • 18
  • 17
  • 16
  • 15
  • 15
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Passivhus : En jämförelse mellan olika byggnadstekniska lösningar för ytterväggar

Enjebo, Jonas, Wallentin, Martin January 2012 (has links)
This report aims to examine the design of a passive house. The design addresses the selection of material, sizing and selection of both building services systems and building technical features such as load-bearing framework and moisture control. Interior layout is designed for a family of two adults and one child. A big part of the report is devoted to an in-depth comparison of three different wall constructions of passive house standard. The structures that have been compared are a lightweight timber structure, a heavier concrete structure and a sandwich wall of the brand Weber Leca. The report covers various aspects such as air flow, wall thickness, the risks associated with the construction, U-value, thermal bridges, power consumption, price, and assembly costs. The purpose is to decide what kind of wall that would be the best option for the house. To give a satisfactory answer to this, two other questions first needed to be answered; "what is a passive house?" and "what is the difference between a passive and an ordinary house?" . It doesn´t exist a clear definition of what a passive house is, however, Forum för energieffektiva byggnader (roughly translated in to the Forum for energy efficient buildings , referred to in the text as: FEBY) has developed a specification for low energy houses. The specification contains specific numbers on how much power and energy a house can consume and still be called a passive house. The main difference between an ordinary house, and a passive house turned out to be precisely those numbers. It is worth noting that no specific requirements, except requirements for U-values of windows, is required by the design itself to be called a passive house as long as you meet the energy and power specification (Erlandsson et al., 2009). The final analysis for the three wall structures were made using a weighting table and the result was that the concrete wall was the best suited for this purpose. When the house was planned with this wall structure it manage to accomplish the FEBY requirements that have been addressed in this report and thus can be presented as "projected for Passive Houses accorded to FEBY" (Erlandsson et al., 2009).
52

Fukt i relation till vind och temperatur i passivhus : Alsters föskola / Moisture in relation to wind and temperature in passive houses : Alsters preschool

Davidsson, Alexandra January 2017 (has links)
No description available.
53

Från normhus till passivhus Utökade krav på organisation och framställning för hus 1 i Kallebäck / From standard house to passive house Extended demands on the organization and the development of ”hus 1” in Kallebäck.

Larsson, Lars January 2008 (has links)
Från standardhus till passivhus - Utökade krav på organisationoch framställning för hus 1 i KallebäckPassivhus är ett energismart byggnadssätt ur miljösynpunkt. Detfinns delade meningar huruvida passivhus är det framtidabyggnadssättet då dess ekonomiska vinning ifrågasätts. Den aktuellarapporten innehåller en analys över vad det innebär att bygga ettpassivhus kontra om det skulle ha byggts enligt standardnormerna.Det hus som används som referens är AF Byggs hus 1 i Kallebäck,vilket byggs idag enligt standardnormerna. Rapporten visar vilkaåtgärder gällande installationer och konstruktion som är nödvändigaför att byggnaden skall klassas som ett passivhus. Vidare finns detäven en analys över vilka förväntningar som väntas ställas påorganisationen under byggprocessen.Vad som framgår av rapporten är att det krävs ganska storaförändringar gällande både konstruktion och installationslösningarför att man skall nå passivhus nivå. En av de stora utmaningar somhittats är att passivhus konceptet bygger på att man inte får ha någotuppvärmningssystem. Vidare har det även framkommit att det ställshögre krav på organisationen. / Uppsatsnivå: C
54

Ett holistiskt synsätt vid husprojektering : En explorativ livscykelstudie av inbyggd och operationell energi för ett passivhus - vilka är energibovarna?

Lindgren, Jenny January 2018 (has links)
Ett holistiskt synsätt vid husprojektering. Det här examensarbetet presenterar en utforskande studie av den inbyggda- och operationella energin ur ett livscykelperspektiv hos ett passivhus. Där aspekter som påverkan från valet av isoleringsmaterial, miljöeffekter och geografisk placering behandlats. Med syftet att undersöka vilken procentuell variation av livscykelenergin för operationell- och inbyggd energi som sker när omgivningarna för ett passivhus ändras mellan Kiruna, Luleå och Malmö samt om isoleringsmaterialet ändras. Studien har begränsats till att undersöka den inbyggda energin hos isoleringsmaterialet som ingår i takkonstruktionen av passivhuset och miljöeffekter har bedömts utifrån energianvändning och CO2-utsläpp. Simulationer av den operationella energin utfördes för åtta olika uppsättningar av isoleringar i tre olika orter där en livslängd på 50 år antagits för huset. Två av isoleringarna hade en mycket högre energiförbrukning vid tillverkning och transport än de övriga. För de med lägre energibehov stod den inbyggda energin i isoleringsmaterialet för i Kiruna mellan 10-15 %, i Luleå mellan 15-20 % och i Malmö mellan 5-10 % av den totala livscykelenergin hos huset när den aktuella energimixen för uppvärmning användes vilket innebär att energibehovet beskrevs i primärenergiresurser tillverkade av icke förnyelsebara resurser. För de med högre energianvändning var samma förhållande mellan 25-35 %, 30-45 % och 20-30 %. Inget samband hittades mellan CO2-utsläpp för de olika undersökningarna och energibehovet vid tillverkning. Resultatet visar på en tydlig inverkan från den inbyggda energin för isoleringen på hela livscykelenergin därför dras slutsatsen att större hänsyn och ett helhetsperspektiv för miljöpåverkan från byggmaterialen bör tas då ett hus ska designas där all energiförbrukning för huset beskrivs i icke förnyelsebara energikällor. / A holistic approach on construction planning. This master thesis presents an exploratory study of the embodied- and operational energy of a passive house from a life cycle perspective. Where aspects such as the effect of insulation choice, environmental impacts and geographic location are treated. With the objective to investigate the variation of the life cycle energy for operational- and embodied energy when the surroundings for a passive house changes between Kiruna, Luleå and Malmö and the insulation material varies. The study is limited to examine the embodied energy of the insulation in the roof construction of a passive house. Environmental impacts have been assessed on the basis of energy consumption and carbon emissions. Simulations of operational energy was performed for eight different sets of insulation in three different places where a life span of 50 years was adopted for the house. Two of the insulations were found to have a much greater embodied energy than the other. For those insulations with lower energy the embodied energy was in Kiruna between 10-20 % in Luleå between 15-30 % and in Malmö between 5- 10% of the total life cycle energy for the house when the actual energy mix for heating was used, which means that the energy was described in primary energy made of non-renewable resources. For those with higher embodied energy the same ratio was between 35-55 %, 50-80 % and 25- 50 %. No correlation was found between carbon dioxide emissions and the embodied energy of the various studies. The result indicates a great impact of the insulation on the total life cycle energy it is therefore concluded that a better account for the environmental impact of building materials should be taken when a house is designed where all of the energy demands of the house are presented in nonrenewable energy resources.
55

Lufttäta byggnader

Davidsson, Sara, Bagger, Conny January 2010 (has links)
<p>The viscosity of air buildings is a hot topic within the construction performers, which the industry feel they have too little knowledge about. This study is mainly aimed against air density in apartment buildings and airflow measurement. The study consists of a theoretical reference, educational visit, interviews and a survey conducted among construction workers at Magistratshagen in Linkoping.</p><p>Earlier requirement in terms of air leakage through the climate screen was removed and today there are only energy requirement for a dwelling in Boverkets Building Regulations. The difference between a passive and a typical air tight construction is that the passive house have a maximum requirement of 0.3 l /s m<sup>2</sup> of air leakage through the building climate screen. The requirement imposed on passive houses is to minimize the supply of power and energy for heating the building.</p><p>Air tight constructions have heavy demands on the performance and accuracy of everyone involved with the project. The client must specify their requirements and also be prepared to pay for any additional costs. The architect and building planners have to design the building with regard to air tightness. Finally, the construction workers are required to do a careful work in order to get all the connections in the building air tight.</p><p>The study suggests that an air tight building is a closed system where no forced ventilation exists. There are no reasons not to build too tight as long as there is a functioning ventilation. In this study the authors ask themselves how an air tight building changes over time. No theoretical information has been found on these changes, but the respondents assume that air density decreases with time. The deterioration is mainly assumed to be caused by construction materials changes over time. The study shows that construction workers knowledge of air tight construction is mixed, which they themselves admit in the survey.</p>
56

Ett aktivt beslut att renovera passivt : En ekonomisk jämförelse vid upprustning av miljonprogrammetsflerbostadshus

Gullmarstrand, Olof, Lindblom, Thomas January 2010 (has links)
No description available.
57

Prefabricerade Passivhus / Prefabricated Passive House

Andersson, Marie, Eriksson, Sophie January 2011 (has links)
European Union has made a new decision that all new built houses by 2020 shallbe near-zero energy houses. Boverket’s definition of near-zero energy housesintends buildings with good energy performance in which a proportion of theamount of energy that must be added to the building is made of renewable energy.Passive House is a set of requirements from FEBY designed to build energyefficient buildings. This is achieved by reducing loss of heat through the buildingenvelope and to take advantage of the passive heat from solar radiation,installation and heat sources like people living in the house.This project has been made with help of Anebyhus and one of their model houseshave been examined from the report’s issues, including Anebyhus’s energyperformance, requirements for the manufacturing and assembly, how theenvelope must be improved to fulfill the requirements for the Passive House andwhat energy calculation programs are available on the market.The report aims to provide solutions for energy efficient houses that are adaptedfor production of house building.Two visits to Anebyhus has been done to study their manufacture and assemblyof building elements. The Energy calculation programs that have beeninvestigated calculates the specific energy consumption of a building.Anebyhus manage today BBR’s requirement of 55 kWh/m2 and year, but has notbegun designing or building any Passive Houses. They have no specialrequirements for the design of their houses only that it should be possible to buildusing their present manufacturing and assembly process. The dimentions of thebuilding elements is mainly restricted by the ability to transport the items on thetruck to the construction sites.The important part of prefabricated construction is the assembly because it isimportant that the house is built tightly so that no moisture or air leakage gets into or out of the building. This is particularly important in Passive House buildingas the construction making demands higher accuracy.The focus of the report is on the building envelope to Anebyhus’s model house.To manage the stricter requirements that Passive House needs the whole buildingenvelope needs to be replaced with better insulated constructions. Also theheating and ventilation systems must be changed to handle the requirements.Energy calculations were made both by hand and by using the energy calculationprogram TMF. The results show that the Passive House we studied just manageFEBY’s demands for a Passive House, which is 50 kWh/m2 and year when solarpanels are installed on the roof to cover the needs for hot water in the summer.The conclusion is that Anebyhus doesn’t have a particularly long way to go in thePassiv House technique, as the house Sadelvägen, which we studied, basicallyfulfill the requirements for a low-energy house. To meet the requirement withoutthe solar panels, extra insulation would be needed, though the machines atAnebyhus aren’t capable of that today. / EU har tagit ett nytt beslut om att alla nyproducerade hus år 2020 ska vara näranollenergihus.Boverkets definition på nära-nollenergibyggnader avser byggnadermed god energiprestanda där en hög andel av den mängd energi som måstetillföras byggnaden utgörs av förnybar energi.Passivhus är en uppsättning krav från FEBY som syftar till att bygga energisnålahus. Detta uppfylls genom att minska förlusterna av värme genom klimatskaletsamt att ta tillvara den passiva värmen från solinstrålning, installationer ochmänniskor i huset.Detta examensarbete har gjorts i samarbete med Anebyhus. Ett av deras typhushar undersökts utifrån rapportens frågeställningar som bland annat tar uppAnebyhus energiprestanda, krav från tillverkning och montering, hur klimatskaletska kunna förbättras för att uppfylla kraven för ett Passivhus samt vilkaenergiberäkningsprogram som finns att tillgå på marknaden.Syftet med rapporten är att ta fram lösningar för energieffektiva hus som ärproduktionsanpassade för småhusindustrin.Två besök på Anebyhus har gjorts för att ta reda på hur deras tillverkning ochmontering av byggnadselement fungerar. Energiberäkningsprogrammen som harundersökts räknar ut den specifika energianvändningen för en byggnad.Anebyhus typhus klarar idag BBR:s krav på 55 kWh/m2 och år, men har intebörjat utforma eller bygga några Passivhus. De har inga speciella krav påutformningen på sina hus bara det går att bygga. Byggnadselementens måttpåverkas främst av möjligheten att kunna frakta elementen på lastbil tillbyggarbetsplatserna.Den viktigaste delen vid prefabricerade byggen är själva monteringen då det ärviktigt att huset blir tätt så inte fukt kommer in i byggnaden samt att det inteuppstår luftläckage. Detta är särskilt viktigt vid Passivhusbyggen eftersomkonstruktionen ställer högre krav på noggrannheten.Fokus i rapporten ligger på förbättringen av klimatskalet till Anebyhus typhus. Föratt klara de strängare Passivhuskraven behöver hela klimatskalet bytas ut motbättre isolerade konstruktioner. Även värme- och ventilationssystem måste bytasut för att klara kraven.Energiberäkningar gjordes både för hand och med energiberäkningsprogrammetTMF. Resultatet visar att Passivhuset vi studerat precis klarar FEBY:s krav för ettPassivhus som ligger på 50 kWh/m2 och år då solfångare installeras på taket föratt täcka varmvattenbehovet på sommarhalvåret.Slutsatsen är Anebyhus inte har speciellt lång väg att gå tills de nårPassivhuskraven, eftersom typhuset Sadelvägen, som vi studerat, i stort sett klararkraven för ett Minienergihus. För att klara kravet utan solfångare skulle dock extraisolering behövas, vilket maskinerna på Anebyhus inte klarar av idag.
58

Uppföljning av energiprestanda samt boendes upplevelser av Portvakten Söder : Energy Monitoring and residents' perceptions of Portvakten Söder / Energy Monitoring and residents perceptions of Portvakten Söder

Alajbegovic, Faruk, Imsirovic, Alen January 2013 (has links)
Portvakten Söder i Växjö, med sina två huskroppar och 64 lägenheter är de högsta passivhusen i Sverige med en trästomme. En energiuppföljning görs för år 2012. Skillnader kring projekterat och uppmätt värde behandlas och klargörs. Granskning av funktionalitet och värmeåtervinningsmängd av avloppsvärmeväxlaren utreds. Ett frågeformulär har skickats ut och sammanställts, där hyresgästerna delar med sig av sina upplevelser utav Portvakten Söder.
59

Kretsloppsanpassat energi- och avloppssystem för ett fritidshus

Wiklund, Patrik January 2013 (has links)
En genomsnittlig villa på 149 m² i Sverige med direktverkande el för uppvärmning använder ungefär 23980 kWh el per år. Av detta så står uppvärmningen för ungefär 13480 kWh, eller 90,5 kWh/m². Att minska denna energianvändning är gynnsamt både för miljönoch ekonomin.Genom att utrusta ett hus på ungefär 161 m² med energisnål utrustning, luftvärmepumpar, bra isolering, ett effektivt ventilationssystem och solfångare så kan elanvändningenminskas med ungefär 20170 kWh per år, till en användning på ungefär 4900 kWh per år.Vad uppvärmningen beträffar så är detta en minskning från 14570 kWh (90,5kWh/m²) till ungefär 1400 kWh (9,4 kWh/m²). Skulle huset användas som ett fritidshus under åtta månader per år, så skulle elanvändningen bara hamna på ungefär 2500 kWh, vilket iförhållande till den uppskattade energianvändningen på 10035 kWh för motsvarande tidsperiod innebär en minskning på ungefär 7535 kWh. För värmens del så innebär detta en minskning från 3035 kWh (18,85 kWh/m²) till ungefär 256 kWh (1,6 kWh/m²).Varmvatten kan fås från solfångare. Om huset används under de åtta soligaste månaderna så skulle varmvattenbehovet nästan helt täckas med fyra solfångare av typ DAC-H 150L. Det som inte täcks av solfångarna kan en elektrisk varmvattenberedare täcka.För att ta tillvara på näringsämnena i toalettavfallet så kan en separationstoalett användas.En bonde som tar hand om toalettavfallet och använder det som gödning skulle tjäna ungefär 330 kr för varje person vars närsalter bonden omhändertar. Om skörden är god så motsvarar detta 9900 kr/ha. Det är mer än vad själva skörden ger.För att rena vattnet från bad, dusch och tvätt (BDT-vatten) så kan en IN-DRÄN infiltrationsbädd användas. Denna kommer att rena BDT-vattnet från närsalter, i de flesta avseenden bättre än ett kommunalt reningsverk. Om träd planteras runt biobädden så kande även rena vattnet från de närsalter som inte renas av biobädden, som annars skulle kunna orsaka övergödning.En stor del av elbehovet skulle kunna täckas med ett solcellssystem. Med ett system med 36 st solpaneler av typ PPAM Paladium, och en växelriktare av typ Sunny Tripower 8000 TL så skulle det produceras ungefär 7600 kWh/år. Det finns även möjlighet att få statligt solcellsstöd på upp till 45% av investeringskostnaden. Det innebär att bara 55% av priset behöver betalas med egna pengar. Dessutom så kan överskottet som solpanelerna producerar säljas.Den totala kostnaden för att energianpassa huset skulle uppskattningsvis hamna på ungefär 439100 kr utan solcellsstöd, samt 368100 kr med solcellsstöd. Då antas det att ingen mängdrabatt fås och att priserna inte är nedprutade. Det kan alltså potentiellt bliännu billigare än beräknat.Om solcellsstöd kan fås så är det fördelaktigt att ingå avtal om mikroproduktion med Vallentuna Energi, som tillämpar nettodebitering. Om huset är bebott året om så blir den uppskattade payback-tiden 6 år, och NPV-värdet blir 654966 kr. Om huset bara är bebott under åtta månader så blir motsvarande siffror 9,9 år respektive 231383 kr. Notera att dessa siffror gäller då det energianpassade huset jämförs med ett vanligt hus meddirektverkande el.Om solcellsstöd inte kan fås så är det bättre att ingå avtal om mikroproduktion med Telge Energi. De tillämpar inte nettodebitering, men de köper överskottselen för ett mycket fördelaktigt pris på 2,5 kr/kWh om solcellsstöd inte har erhållits. Om huset är bebott året om så blir den uppskattade payback-tiden 6,4 år och NPV-värdet blir 642716 kr. Om huset är bebott under åtta månader så blir siffrorna istället 10,2 år och 179914 kr.
60

Lufttäta byggnader

Davidsson, Sara, Bagger, Conny January 2010 (has links)
The viscosity of air buildings is a hot topic within the construction performers, which the industry feel they have too little knowledge about. This study is mainly aimed against air density in apartment buildings and airflow measurement. The study consists of a theoretical reference, educational visit, interviews and a survey conducted among construction workers at Magistratshagen in Linkoping. Earlier requirement in terms of air leakage through the climate screen was removed and today there are only energy requirement for a dwelling in Boverkets Building Regulations. The difference between a passive and a typical air tight construction is that the passive house have a maximum requirement of 0.3 l /s m2 of air leakage through the building climate screen. The requirement imposed on passive houses is to minimize the supply of power and energy for heating the building. Air tight constructions have heavy demands on the performance and accuracy of everyone involved with the project. The client must specify their requirements and also be prepared to pay for any additional costs. The architect and building planners have to design the building with regard to air tightness. Finally, the construction workers are required to do a careful work in order to get all the connections in the building air tight. The study suggests that an air tight building is a closed system where no forced ventilation exists. There are no reasons not to build too tight as long as there is a functioning ventilation. In this study the authors ask themselves how an air tight building changes over time. No theoretical information has been found on these changes, but the respondents assume that air density decreases with time. The deterioration is mainly assumed to be caused by construction materials changes over time. The study shows that construction workers knowledge of air tight construction is mixed, which they themselves admit in the survey.

Page generated in 0.0657 seconds