• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 105
  • 34
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 152
  • 152
  • 90
  • 80
  • 73
  • 21
  • 21
  • 20
  • 20
  • 20
  • 19
  • 17
  • 16
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Eletrogoniometria de punho : avaliação de sensores e procedimentos matemáticos de correção para reduzir erros de medida

Foltran, Fabiana Almeida 21 February 2013 (has links)
Made available in DSpace on 2016-06-02T20:19:21Z (GMT). No. of bitstreams: 1 5110.pdf: 9251183 bytes, checksum: b4178b3d81d86cf5fd17ce7ecbba1aa8 (MD5) Previous issue date: 2013-02-21 / Financiadora de Estudos e Projetos / The human movement record is an essential requirement for biomechanical, clinical and occupational analysis, allowing assessments of postural variation, occupational risks and improvement of preventive programs in physical therapy and rehabilitation. Electrogoniometers have been used to record wrist movements during work. However, different sizes of sensors are used, bringing difficulties to the comparison of recordings. Moreover, although of flexible electrogoniometers (EGM) are considered a reliable and accurate equipment for dynamic recordings of different joints the EGM, they are susceptible to measurement errors, known as crosstalk. There are two main types of crosstalk, crosstalk due to sensor rotation and the inherent crosstalk. Correction procedures have been proposed to correct these errors, however no study evaluating the efficiency of corrections from both procedures in subject wrist measurements was identified in the available literature. Thus, this study aims: 1) to evaluate two different sensors in order to check its performance in an anthropometric defined sample; 2) to evaluate the effects of mathematical correction procedures on: the crosstalk due to the forearm rotation, the inherent sensors crosstalk, and the combination of these two procedures. To compare the two models of sensors 13 subjects were evaluated (7 women and 6 men) who performed flexion/extension and ulnar/radial wrist movement, reaching maximum amplitude in the pronated forearm position. Two sensors measuring 65 and 110 mm of length (XM110 and XM65, respectively) and an acquisition data device (Datalog, Biometrics) were used. The sequence of movements and the sensor placement were randomized. The data were analyzed descriptively and statistically bymultivariate analysis. The intra-individual variation (root mean square RMS between trials) were calculated. The results showed there was no significant difference between the sensors for all movements. The maximum intra individual variation was 2.2°. There were significant differences between gender for wrist flexion and ulnar deviation, women have higher values than men. The maximum variability between sensors was 7.1°. Although no significant difference was identified between sensors, it was found that the sensor XM110, bigger than XM65, presented bulging during the extension. Therefore, for individuals with height up to 1.8 m, the data obtained by both sensors are comparable. In the second stage of the study we evaluate the maximum amplitude of the flexion/extension and ulnar deviation/radial wrist of 43 healthy subjects recorded by EGMs. Correction procedures were applied to the crosstalk due to the rotation of the forearm, crosstalk inherent and combining the two procedures. The results showed there was no significant difference in measurements before and after the correction procedures (P≤0.05). Furthermore, the differences between the correction procedures were below 5 ° for most cases, indicating small clinical impact on the measurements. Considering that the corrections are time consuming, require specific technical knowledge and have provided inefficient results, the correction procedures are not recommended for clinical wrist electrogoniometers recordings. Thus, improvement of equipment should be provided by the manufacturers. / O registro do movimento humano e requisito fundamental para analises biomecanicas, clinicas e ocupacionais, permitindo avaliar variacoes posturais, riscos e aprimoramento de programas preventivos e de reabilitacao em Fisioterapia. O eletrogoniometro e utilizado em contexto ocupacional para registro dos movimentos do punho. No entanto, diferentes tamanhos de sensores sao utilizados, o que pode dificultar a comparacao entre os resultados. Alem disso, apesar de o eletrogoniometro flexivel (EGM) ser considerado um equipamento confiavel e acurado, e utilizado para o registro dinamico de diferentes articulacoes, e suscetivel a erros de medida, denominados crosstalk. Existem dois tipos principais de crosstalk, o crosstalk devido a rotacao do sensor e o crosstalk inerente. Procedimentos de correcao tem sido propostos para a correcao desses erros, no entanto nenhum estudo utilizou ambos os procedimentos em medidas em movimento funcional dos movimentos do punho, visando otimizar a correcao. Diante disso, este estudo teve como objetivos: 1) avaliar dois sensores eletrogoniometricos de tamanho diferentes para verificar o desempenho de ambos em uma amostra com variaveis antropometricas (peso e altura) definidas; e 2) avaliar, comparativamente, o efeito de procedimentos de correcao para: o crosstalk entre os movimentos de flexao/extensao e desvio radial/ulnar do punho devido a rotacao do antebraco; o crosstalk inerente aos sensores, e a combinacao desses dois procedimentos de correcao em situacoes funcionais. Para a comparacao entre os dois modelos de sensores foram avaliadas 13 sujeitos (7 mulheres e 6 homens) que realizaram movimentos de flexao/extensao e desvio ulnar/radial do punho em amplitude maxima, na posicao pronada do antebraco. Foram utilizados dois sensores com 65 e 110 mm de comprimento (XM65 e XM110, respectivamente) e um dispositivo de aquisicao de dados (Datalog, Biometrics). A ordem de realizacao dos movimentos e colocacao dos sensores foram aleatorizadas. Os dados foram analisados descritivamente e estatisticamente por analise multivariada. Foi calculada a variacao entre as tentativas (variabilidade intra individual) e entre os sensores por meio do valor RMS (root mean square). Os resultados mostraram que nao houve diferenca significativa entre os sensores para todos os movimentos. A variabilidade intraindividual maxima foi de 2,2°. Houve diferenca significativa entre os generos para a flexao e o desvio ulnar, sendo as mulheres as que apresentaram valores maiores que os homens. A variabilidade maxima entre os sensores foi de 7,1°. Apesar de nao ter havido diferenca significante entre os sensores, verificou-se que o sensor XM110, por ser maior, apresentava abaulamento durante a extensao. Portanto, para individuos com altura ate 1,8 m, os dados obtidos pelos diferentes sensores sao comparaveis. Na segunda etapa do estudo foram avaliadas as amplitudes maximas dos movimentos de flexao/extensao e desvios ulnar/radial do punho de 43 individuos saudaveis registradas por meio de EGMs. Foram aplicados procedimentos de correcao para o crosstalk devido a rotacao do antebraco, crosstalk inerente, e combinando-se os dois procedimentos. Os resultados mostraram que nao houve alteracao significativa nas medidas apos a aplicacao dos procedimentos de correcao (P≤0,05). Alem disso, as diferencas entre os procedimentos de correcao foram inferiores a 5o para a maioria dos casos, indicando pouco impacto sobre as medidas. Assim, considerando o tempo de processamento, o conhecimento tecnico especifico exigido e os ineficazes resultados obtidos, desaconselha-se a aplicacao desses procedimentos na correcao de registros eletrogiometricos do punho, sugerindo a necessidade de que o aprimoramento dos equipamentos seja realizado por seus fabricantes.
132

Validade e reprodutibilidade do Wii Balance Board para avalia??o do equil?brio vertical est?tico: um novo m?todo de avalia??o.

Silva, Nathalia Priscila Oliveira 27 February 2014 (has links)
Made available in DSpace on 2014-12-17T15:16:20Z (GMT). No. of bitstreams: 1 NathaliaPOS_DISSERT.pdf: 1603301 bytes, checksum: 3c0c1f2df3c4b9a36151d032eba2a9d1 (MD5) Previous issue date: 2014-02-27 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The Wii Balance Board (WBB) began to be investigated as a low-cost alternative for assessing static balance in vertical posture. However, studies employed methodological procedures that did not eliminate result variability between the tests and equipment used. Objective: Determine the validity and reproducibility of the WBB as an instrument for assessing static balance in the vertical position, using simultaneous data analysis and superimposed equipment. Methods: This is an accuracy study of 29 healthy young individuals of both sexes aged 18 to 30 years. Subjects were assessed 24h apart (test-retest), using unipodal and bipodal support tests, with eyes closed and open. To that end the WBB was placed on top of a force platform (FP) and data (postural sway) were collected simultaneously on both devices. Validity and reproducibility were analyzed using the interclass correlation coefficient (ICC). Finally, Bland-Altman analysis was applied to assess agreement. Results: The sample was composed of 23 women and 6 men, with mean age of 24.2?6.3 years, 60.7?6.3 kg and 1.64?4.2 m. The validity of the WBB compared to the FP was excellent for all 4 tasks proposed (ICC = 0.93 0.98). The reproducibility analyzed by test-retest was excellent for the bipodal support tasks (ICC = 0.93-0.98) and only moderate for the unipodal support tests (ICC = 0.46 0.70). Graphic analysis exhibited good agreement between the devices, since most of the measures were within the limits of agreement. Conclusion: this study proved the validity and reproducibility of the Wii Balance Board as an instrument for assessing static balance in vertical posture, using simultaneous analysis with superimposed equipment. Thus, the WBB has been increasingly used by physical therapists and other health professionals in their clinical practice, as both a rehabilitation and assessment tool / O Wii Balance Board (WBB) passou a ser investigado como uma alternativa de baixo custo para avalia??o do equil?brio est?tico na postura vertical. No entanto, as pesquisas utilizaram procedimentos metodol?gicos que n?o eliminaram a variabilidade de resultados existente entre os testes e equipamentos utilizados. Objetivo: Averiguar as propriedades de validade e reprodutibilidade do WBB como instrumento para avalia??o do equil?brio est?tico na postura vertical, por meio do m?todo de an?lise simult?nea de dados com a sobreposi??o de equipamentos. M?todos: Trata-se de um de estudo de acur?cia, no qual foram avaliados 29 jovens saud?veis de ambos os sexos de 18-30 anos. Os inviv?duos foram avaliados em 2 momentos distintos com intervalo de 24h (teste-reteste), atrav?s de testes de apoio unipodal e bipodal com olhos fechados e abertos. Para isso o WBB foi colocado sobre a Plataforma de for?a (PF) e a coleta dos dados (deslocamento total do Centro de Press?o) foi feita simultaneamente em ambos equipamentos. A validade e reprodutibilidade foram analisadas atrav?s do coeficiente de correla??o intraclasse (CCI). Por fim, foi feita uma an?lise de concord?ncia por meio do m?todo de Bland-Altman. Resultados: A amostra foi composta por 23 mulheres e 6 homens, com idade m?dia de 24,2?6,3 anos, 60,7?6,3 kg e 1,64?4,2 m. A validade do WBB em compara??o com a PF mostrou-se excelente para todas as 4 tarefas propostas (CCI = 0,93 0,98). A reprodutibilidade analisada atrav?s do teste-reteste mostrouse excelente para as tarefas de apoio bipodal (CCI = 0,93 0,88) e apenas moderada para os testes de apoio unipodal (CCI = 0,46 0,70). Na an?lise gr?fica, viu-se uma boa concord?ncia entre os dispositivos, j? que a maioria das medidas encontra-se dentro dos limites concord?ncia. Conclus?o: esta pesquisa provou a validade e reprodutibilidade do Wii Balance Board como um instrumento para avalia??o do equil?brio est?tico na postura vertical, atrav?s da an?lise simult?nea com sobreposi??o de equipamentos. Tornando o WBB cada vez mais vi?vel para sua utiliza??o na pr?tica cl?nica pelos fisioterapeutas e diversos profissionais de sa?de, n?o apenas como uma ferramenta de reabilita??o mas tamb?m de avalia??o
133

Avaliação da função de membros superiores: desafios na reabilitação física de pacientes pós-AVC / Upper limb functional outcomes: challenges in stroke patients rehabilitation

Thaís Tavares Terranova 22 July 2016 (has links)
INTRODUÇÃO: O acidente vascular cerebral (AVC) ocupa as primeiras posições entre as principais causas de incapacidade no mundo, sendo que 45% dos sobreviventes permanecem com perda persistente da função motora de membro superior. Diversos estudos relacionados à reabilitação de pacientes pós-AVC têm como objetivo avaliar intervenções para melhora da função motora de membros superiores. Assim, é fundamental que os resultados sejam avaliados de maneira confiável a fim de se garantir dados objetivos que facilitem a comparação entre as diferentes intervenções. No presente trabalho, discutimos as dificuldades inerentes ao contexto de seleção e administração de diferentes instrumentos de avaliação, e sugerimos uma nova metodologia com o objetivo de oferecer maior confiabilidade e sensibilidade ao processo de avaliação da funcionalidade de membros superiores em pacientes pós-AVC. MÉTODOS: Dividimos o conteúdo deste trabalho em duas etapas: I) revisão da bibliografia, na qual foram identificados diferentes instrumentos de avaliação funcional e discutidas suas propriedades psicométricas; II) análise estatística exploratória para detectar possível relação de dependência entre as variáveis obtidas pelo instrumento Wolf Motor Function Test (WMFT) e as variáveis obtidas pelo dispositivo robótico para membro superior coletadas em uma amostra de 41 pacientes em programa de reabilitação. RESULTADOS: Selecionamos 62 publicações que avaliaram as propriedades psicométricas dos instrumentos de avaliação da função de membros superiores pós-AVC. Pela análise dos artigos, identificamos 22 instrumentos e classificamos pelos níveis de funções e estruturas do corpo, e atividade de acordo com a Classificação Internacional da Funcionalidade (CIF). Comparamos os parâmetros das propriedades psicométricas dos 22 instrumentos e selecionamos o WMFT como um instrumento de referência, factível e bem conceituado, para testar a relação de dependência com as variáveis do dispositivo robótico. A partir da análise estatística exploratória, verificamos relação de dependência entre três das variáveis robóticas e a pontuação do WMFT tempo, demonstrada pela significância no teste LIS (p < 0.05), porém a correlação não foi demonstrada pela representação gráfica. CONCLUSÕES: Embora o WMFT seja bem avaliado quanto às propriedades psicométricas, ele apresenta aspectos negativos que impactam na qualidade dos dados coletados, como, por exemplo, subjetividade durante a observação, tempo de aplicação, treinamento dos avaliadores, além de não fornecer informações sobre a coordenação. Por outro lado, dispositivos robóticos produzem variáveis cinéticas e cinemáticas, as quais fornecem variáveis contínuas, objetivas e precisas sobre diferentes aspectos da função de membros superiores como velocidade, coordenação e força. Portanto, tais equipamentos são alternativas eficazes com relação à aplicação de instrumentos de avaliação do desempenho atual como o WMFT. Futuramente, sugerimos estudos que incluam uma amostra mais robusta e diversificada quanto ao grau de incapacidade, para que análise possa ser ampliada para uma modelagem estatística das variáveis / INTRODUCTION: Stroke occupies the first position among the leading causes of disability worldwide, with 45% of survivors remain with persistent loss of motor function of the upper limb. Several studies related to stroke rehabilitation evaluates interventions to improve motor function of upper limbs. Thus, it is fundamental that results are evaluated reliably in order to ensure objective data to facilitate comparison between different interventions. In this paper, we discuss the difficulties inherent in the context of selection and management of different evaluation tools and suggest a new methodology in order to provide greater reliability and sensitivity in the evaluation process of the functionality of the upper limbs in poststroke patients. METHODS: We divided the contents of this work in two steps: I) review of the literature in which identified different functional assessment tools and discussed its psychometric properties; II) exploratory statistical analysis to detect possible relationship of dependency between variables obtained by the instrument Wolf Motor Function Test (WMFT) and the variables obtained by the robotic device for upper limb collected in a sample of 41 patients in rehabilitation program. RESULTS: We selected 62 publications evaluating the psychometric properties of upper limb assessment tools. For the analysis of the articles, we identified 22 instruments and classified by levels of functions and structures of the body and activity according to the International Classification of Functioning (ICF). We compared the parameters of the psychometric properties of the 22 instruments and selected the WMFT as a reference tool, feasible and well-regarded, to test the dependency relationship with the variables of the robotic device. From the exploratory statistical analysis verified dependence between three of the robotic variables and the score WMFT time, demonstrated the significance in test LIS (p < 0.05), but the correlation was not shown by the graphical representation. CONCLUSIONS: Although WMFT has excellent psychometric properties, it has negative aspects that impact in quality of data collected, for example, subjectivity during observation, application time, training of evaluators, besides it does not provide information on the coordination. On the other hand, robotic devices produce kinetic and kinematic variables which provide continuous, accurate and objective variables on different aspects of the upper limb function such as speed, coordination and strength. Therefore, such devices are effective alternatives regarding to assessment tools of current performance as WMFT. In the future, we suggest studies that include a more robust and diverse sample with respect to the degree of disability, so that analysis can be extended to a statistical modeling of the variables
134

Reprodutibilidade da curva tensional diária modificada e do teste de sobrecarga hídrica / Reproducibility of the modified daily tension curve and the water drinking test

Marcelo Hatanaka 16 May 2014 (has links)
OBJETIVO: avaliar a reprodutibilidade da curva tensional modificada e do teste de sobrecarga hídrica em portadores de glaucoma de ângulo aberto ou hipertensos oculares, sem uso de hipotensor ocular, em dois dias consecutivos. MÉTODOS: análise prospectiva de pacientes portadores de glaucoma de ângulo aberto ou hipertensos oculares, submetidos à curva tensional modificada (medida da pressão intraocular às 8h, 11h, 14h e 16h), seguida do teste de sobrecarga hídrica (três medidas com intervalo de 15 minutos, iniciando-se 15 minutos após a ingestão, em cinco minutos, de um litro de água em temperatura ambiente), realizados pelo mesmo examinador, em dois dias consecutivos. Foram avaliadas: a reprodutibilidade da pressão intraocular em cada horário de medida durante a curva tensional modificada; a reprodutibilidade da pressão intraocular média, flutuação e pico de pressão durante a curva tensional modificada; a reprodutibilidade da flutuação e do pico de pressão durante o teste de sobrecarga hídrica. Calculou-se o coeficiente de correlação intraclasse para cada parâmetro. RESULTADOS: oitenta e oito olhos de 88 pacientes foram estudados. Destes, 64 eram portadores de glaucoma de ângulo aberto. A média das idades dos participantes foi 68,7+10,8 (51-79) anos. 65% dos pacientes eram do sexo feminino. A curva tensional modificada apresentou coeficiente de correlação intraclasse igual a 0,80, 0,82, 0,83 e 0,86 para as medidas realizadas às 8h, 11h, 14h e 16h, respectivamente (p < 0,001). A flutuação da pressão durante a curva tensional modificada, calculada pela diferença entre as pressões máxima e mínima e pelo desvio-padrão da média das medidas diurnas de pressão, a pressão média e o pico pressórico apresentaram coeficientes 0,60, 0,62, 0,91 e 0,85, respectivamente (p < 0,001). Durante o teste de sobrecarga hídrica, a flutuação apresentou coeficiente de 0,37 e o pico pressórico, 0,79. (p < 0,001). CONCLUSÕES: neste estudo, as medidas de pressão intraocular realizadas durante a curva tensional modificada, a média e o pico apresentaram excelentes níveis de reprodutibilidade. O pico pressórico durante o teste de sobrecarga hídrica apresentou também excelente reprodutibilidade. A flutuação, tanto na curva tensional modificada, quanto no teste de sobrecarga hídrica, apresentou os menores índices de reprodutibilidade / OBJECTIVE: to evaluate the reproducibility of the modified daily tension curve and the water drinking test in patients with open-angle glaucoma or ocular hypertension, not under topical treatment, during two consecutive days. METHODS: prospective analysis of open-angle glaucoma or ocular hypertensive patients, submitted to a modified daily tension curve (intraocular pressure measurements at 8AM, 11AM, 2PM and 4PM), followed by the water drinking test (three intraocular pressure measurements with 15 minutes intervals, 15 minutes after ingestion of one liter of tap water), performed by the same examiner, within two consecutive days. The following parameters were evaluated for reproducibility: intraocular pressure obtained at each time-point during the modified daily tension curve; mean, peak and pressure fluctuation during the curve and peak and fluctuation during the water drinking test. Reproducibility was assessed using the intraclass correlation coefficient. RESULTS: eighty-eight eyes from 88 patients were studied. From these, 64 presented open-angle glaucoma. Mean age was 68.7+10.8 (51-79) years. 65% patients were female. Intraclass correlation coefficients were 0.80, 0.82, 0.83 and 0.86 for intraocular pressure measurements at 8AM, 11AM, 2PM and 4PM, respectively (p<0.001) Fluctuation calculated as the difference between maximum and minimum intraocular pressures, fluctuation calculated as the standard deviation of the four daily measurements, mean and peak pressures presented coefficients of 0.60, 0.62, 0.91 and 0.85, respectively (p<0.001). During the water drinking test, coefficient values for fluctuation and peak pressure were 0.37 and 0.79 (p<0.001). CONCLUSIONS: in this study, intraocular pressure measurements during a modified daily tension curve, mean intraocular pressure and pressure peaks presented excellent reproducibility levels; pressure peaks during the water drinking test also presented excellent reproducibility level, whereas fluctuation, both during the modified daily tension curve and during the water drinking test, was the least reproducible parameter
135

Adaptação e validação de escalas de resiliência para o contexto cultural brasileiro: escala de resiliência disposicional e escala de Connor-Davidson / Cross-cultural adaptation and validation of resilience scales for Brazil: dispositional resilience scale and Connor-Davidson resilience scale

João Paulo Consentino Solano 02 June 2016 (has links)
INTRODUÇÃO: a resiliência é um construto associado às características pessoais que permitem a um indivíduo adaptar-se e superar situações adversas. Uma pessoa mais resiliente é aquela com maiores habilidades de se adaptar sob estresse, a despeito da carga de dificuldades enfrentada e de um contexto desfavorável no entorno. A Dispositional Resilience Scale (DRS-15) e a Connor-Davidson Resilience Scale (CD-RISC) tentam aferir a resiliência individual e já tiveram suas propriedades testadas em vários países da América do Norte, África, Europa e Ásia. OBJETIVO: traduzir, realizar a adaptação para o contexto cultural brasileiro e verificar a confiabilidade e a validade das escalas DRS-15 e CD-RISC. MÉTODO: uma metodologia com as etapas seqüenciais de tradução/retro-tradução/adaptação cultural/estudo de confiabilidade/estudo de validade foi utilizada. A adaptação cultural foi executada por um grupo de especialistas em epidemiologia, linguística, psiquiatria e tratamento da dor. A compreensão das versões culturalmente adaptadas foi testada com 65 pacientes adultos do grupo de avaliação pré-anestésica e do ambulatório geral de ansiedade do Hospital das Clínicas da FMUSP. Retro-traduções das versões finais foram aprovadas pelos autores principais das escalas originais. O estudo de validade foi conduzido pela aplicação conjunta de ambas as versões brasileiras das escalas, do Inventário de Sintomas de Stress para Adultos de Lipp (ISSL), do Self-report questionnaire (SRQ), da escala de incapacitação de Sheehan (SDS) e da Escala Graduada de Dor Crônica (CPG-Br) a 575 pacientes e acompanhantes adultos da mesma população. A confiabilidade teste-reteste foi avaliada por uma segunda aplicação das escalas de resiliência a 123 participantes, entre 7 e 14 dias após a entrevista inicial. RESULTADOS: entre os participantes da fase de validação, a idade média foi de 44 anos (amplitude de 18-93), com predomínio de mulheres (74%), e média de dez anos de estudo. A maioria dos entrevistados (93%) pertencia aos estratos socioeconômicos B e C. Três fatores e quatro fatores foram identificados por análise fatorial exploratória para as versões da DRS-15 e CD-RISC, respectivamente. O coeficiente alfa de Cronbach foi de 0,71 para a DRS, e de 0,93 para a CD-RISC, indicando melhor consistência interna para a segunda. A confiabilidade teste-reteste retornou coeficientes de correlação intra-classe de 0,81 e 0,86 para a DRS e CD-RISC, respectivamente. A correlação entre as duas escalas foi de 0,52. Observaram-se correlações negativas significativas entre os escores das escalas de resiliência e os escores para cinco das seis dimensões do ISSL, assim como para com os escores do SRQ e SDS (p < 0,001). Não houve correlação entre as escalas de resiliência e a CPG-Br. A CD-RISC encontrou correlações mais fortes que a DRS para com as variáveis de comparação externa. As duas escalas discriminaram resiliência menor para os pacientes dos ambulatórios psiquiátricos, em comparação aos dos ambulatórios não-psiquiátricos. Entre os pacientes psiquiátricos, os escores de resiliência foram significativamente menores para os pacientes com transtorno Borderline de personalidade, em comparação aos pacientes com transtorno de estresse pós-traumático. CONCLUSÃO: propriedades de consistência interna, estabilidade temporal e validade foram satisfatoriamente demonstradas para as versões brasileiras da DRS e da CD-RISC em uma amostra de pacientes e acompanhantes adultos dos ambulatórios do Hospital das Clínicas de São Paulo / INTRODUCTION: Resilience is a construct related to the personal characteristics that allow an individual to adapt and overcome adversity. A more resilient person is the one that exhibits greater abilities to adapt under stress, despite the burden of difficulties and of an unfavorable context. The Dispositional Resilience Scale (DRS-15) and the Connor-Davidson Resilience Scale (CD-RISC) are two scales to measure individual resilience, both of which have had psychometrics evaluated by researchers from the US, Africa, Europe and Asia. OBJECTIVE: To verify the reliability and validity of culturally adapted Brazilian Portuguese versions of the DRS-15 and CD-RISC. METHODS: The following stepwise methodology was used: translation / back translation / cultural adaptation / reliability study / validation study. Cultural adaptation was performed by an expert committee of epidemiologist, linguists, psychiatrist and pain specialists. Comprehension of the culturally adapted versions was tested through 65 interviews with adult patients from the pre-anesthetic consultation ambulatory and general ambulatory for anxiety disorders of Hospital das Clínicas of FMUSP. Back-translations of the culturally adapted versions were fully approved by the authors of the original scales. Validation studies were carried out by concurrent application of both the adapted versions of resilience scales, the Brazilian Stress Symptoms Inventory for Adults (ISSL), the Self-report Questionnaire (SRQ), the Sheehan Disability Scale (SDS) and the Chronic Pain Grade (CPG-Br) to 575 participants (outpatients and companions) from the same population. Test-retest reliability was studied by means of a second interview with 123 subjects, which took place between 7 and 14 days after the first one. RESULTS: Subjects of the validation phase were mostly women (74%), with an average of 44 years of age (18-93) and 10 years of formal schooling. There was a predominance of socioeconomic levels B or C (93%) on an A to E scale. Exploratory factor analyses resulted in a three-factor for the DRS and a four-factor solution for the CD-RISC. Alpha coefficients of 0.71 for the DRS and 0.93 for the CD-RISC indicated better internal consistency for the latter. Temporal stability was regarded as excellent, with intra-class correlation coefficients of 0.81 and 0.86 for the DRS and CD-RISC, respectively. Correlation coefficient between the two scales was 0.52. Significant negative correlations were observed between the scores of both resilience scales and five out of six dimensions of the ISSL, and so as between the resilience scales scores and those of the SRQ and SDS (p < 0.001). No correlation was observed between the resilience scales and the CPG-Br. The CD-RISC was more competent than DRS to depict such correlations. Both scales were able to discriminate differences in resilience scores of non-psychiatric and psychiatric patients, the latter presenting with lower scores. The group of borderline patients significantly presented with lower resilience scores in comparison with those of the post-traumatic stress disorder patients. CONCLUSION: Good reliability and validity were demonstrated with the Brazilian Portuguese versions of the DRS and CD-RISC as tested on a sample of adult ambulatory patients and their adult companions at Hospital das Clínicas, São Paulo
136

Impacto da educação continuada realizada pelo laboratório de monitoramento externo da qualidade na acuidade dos resultados dos exames citopatológicos do colo do útero / Impact of continued education provided by the external quality control laboratory on the accuracy of the cervical cytopathology exams

Ázara, Cinara Zago Silveira 21 March 2014 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-02-01T16:26:34Z No. of bitstreams: 2 Tese - Cinara Zago Silveira Ázara - 2014.pdf: 1797247 bytes, checksum: dedf8ad11c953018be611e39ac085e44 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-02-02T06:54:08Z (GMT) No. of bitstreams: 2 Tese - Cinara Zago Silveira Ázara - 2014.pdf: 1797247 bytes, checksum: dedf8ad11c953018be611e39ac085e44 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-02-02T06:54:08Z (GMT). No. of bitstreams: 2 Tese - Cinara Zago Silveira Ázara - 2014.pdf: 1797247 bytes, checksum: dedf8ad11c953018be611e39ac085e44 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-03-21 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / The effectiveness of cytopathology exams demands high quality training, continued education and highly skilled professionals to guarantee a reliable, accurate exam, aimed at reducing false results. Objective: To evaluate the effect of a continued education program conducted by the External Quality Control Monitoring Laboratory (LabMEQ), assessing the agreement of the results and internal quality control indicators. Methods: To analyze the agreement of the results, 19,826 exams conducted between 2007 and 2011 and selected through the cervical cancer data system (SISCOLO) were evaluated, 9,798 of these exams having been performed prior to the implementation of continued education and 10,028 after implementation. The statistical analysis was performed using the chi-square test, with p-values < 0.05 being considered statistically significant and the kappa coefficient was calculated. To analyze the internal quality control indicators, 185,194 exams performed between 2007 and 2012 were evaluated. Data for these exams were obtained from the SISCOLO, with 98,133 having been performed prior to the implementation of continued education and 87,061 after implementation. The following indicators were calculated: positivity index (PI), percentage of exams compatible with a high-grade squamous intraepithelial lesion (HSIL/satisfactory), percentage of atypical squamous cells among all abnormal smears (ASC/abnormal) and the ratio between atypical squamous cells and intraepithelial lesions (ASC/SIL). Continued education was provided every two months to the professionals from the participating laboratories in the form of theoretical and practical classes to discuss discordant cases and the standardization of cytomorphological criteria. Results: After the implementation of continued education, a reduction was found in the percentage of false-negative results that lead to delays in clinical management in eight laboratories and there was an improvement in the rate of false-positive results in five. There was no improvement observed in the unsatisfactory results. The agreement of the cytopathology exam results, according to the clinical management, remained excellent in three laboratories (kappa > 0.80), increased from good (kappa > 0.60 and < 0.80) to excellent (kappa > 0.80) in seven and from excellent to good in two laboratories. The agreement in the identification of the metaplastic epithelium, which was poor (kappa = 0.25), was classified as excellent after implementation of the continued education program (kappa = 0.95). The agreement of the results, according to the diagnosis, improved significantly following continued education in unsatisfactory cases (p<0.001), in cases of atypical squamous cells of undetermined significance (ASC-US) and atypical squamous cells cannot exclude HSIL (p<0.001), low-grade squamous intraepithelial lesions (p<0.001) and atypical glandular cells (p<0.001). Following implementation of the continued education program, the positivity index (PI) remained within recommended limits in four laboratories. In another four laboratories, the PI progressed from below the limits to within the recommended standards. In one laboratory, the PI remained low, in two laboratories, it remained very low, and in one, it increased from very low to low. The HSIL/satisfactory remained within the recommended limits in five laboratories, while in three laboratories it progressed from below the recommended levels to >0.4% of the total number of satisfactory exams, and in four laboratories it remained below the standard limit. Both the percentage of ASC/abnormal and the ratio ASC/SIL remained within recommended levels in all the laboratories investigated. Conclusion: The results of this study show that the continued education program conducted by LabMEQ with the laboratories was effective as a measure aimed at standardizing cytomorphological criteria, since there was an improvement in the reproducibility of the results and in the indicators of internal quality control, leading to a reduction in the number of false results. / A efetividade do exame citopatológico requer treinamento de alta qualidade, educação continuada e qualificação dos profissionais para garantir um exame confiável e eficiente, visando à redução de resultados falsos do teste. Objetivo: Avaliar o impacto da educação continuada realizada pelo Laboratório de Monitoramento Externo da Qualidade (LabMEQ), verificando a concordância dos resultados e os indicadores de monitoramento interno da qualidade. Métodos: Para análise da concordância dos resultados foram avaliados 19.826 exames selecionados pelo Sistema de Informações do Câncer do Colo do Útero (SISCOLO) no período de 2007 a 2011, sendo 9.798 anteriores a educação continuada e 10.028 após a educação continuada. A análise estatística foi realizada através do teste de qui-quadrado com p < 0,05 e do coeficiente Kappa. Para a análise dos indicadores de monitoramento interno da qualidade foram avaliados 185.194 exames no período de 2007 a 2012, cujas informações foram obtidas por meio do SISCOLO, sendo 98.133 anteriores a educação continuada e 87.061 após a educação continuada. Foram calculados os indicadores índice de positividade (IP), percentual de exames compatíveis com lesão intraepitelial escamosa de alto grau (HSIL/satisfatórios), percentual de células escamosas atípicas dentre os exames alterados (ASC/alterados) e razão de células escamosas atípicas/lesões intraepiteliais escamosas (ASC/SIL). A educação continuada foi realizada a cada dois meses com os profissionais dos laboratórios por meio de encontros teóricos e práticos para discutir os casos discordantes e uniformização dos critérios citomorfológicos. Resultados: Verificou-se que, após a educação continuada, houve redução no percentual de resultados falso-negativos e com retardo de conduta clínica em oito laboratórios e dos falso-positivos em cinco. Em relação aos resultados insatisfatórios, não houve melhora. A concordância dos resultados dos exames citopatológicos, em relação à conduta clínica, manteve-se excelente em três laboratórios com Kappa>0,80, passou de concordância boa (Kappa > 0,60 e < 0,80) para excelente (Kappa> 0,80) em sete laboratórios e de concordância excelente para boa em dois. A concordância na identificação do epitélio metaplásico que era pobre (Kappa=0,25) passou a excelente (Kappa=0,95). A concordância dos resultados, em relação as categorias de diagnóstico, melhorou significativamente após a educação continuada nos casos insatisfatórios (p< 0,001), células escamosas atípicas de significado indeterminado e não se pode afastar HSIL (p<0,001), lesão intraepitelial escamosa de baixo grau (p<0,001) e atipias glandulares (p<0,001). Após a educação continuada, quatro laboratórios mantiveram o IP dentro do recomendado, quatro que estavam abaixo passaram a ter o IP dentro do recomendado, um permaneceu baixo, dois permaneceram muito baixo e um passou de muito baixo para baixo. Em relação ao indicador HSIL/satisfatórios, cinco laboratórios mantiveram o índice dentro do recomendado, três que estavam abaixo do recomendado passaram a ter esse índice acima de 0,4 e quatro permaneceram abaixo do recomendado. Os indicadores ASC/alterados e razão ASC/SIL mantiveram-se dentro do recomendado em todos os laboratórios. Conclusão: Os resultados desse estudo mostraram que a educação continuada realizada pelo LabMEQ com os laboratórios são eficientes como medida de uniformização dos critérios citomorfológicos uma vez que houve melhoria na concordância dos resultados e nos indicadores de monitoramento interno da qualidade, levando a uma redução dos resultados falsos do teste.
137

Validade e reprodutibilidade de um questionário quantitativo de frequência alimentar para adolescentes portadores de diabetes tipo 1 / Validity and reproducibility of a quantitative food frequency questionnaire for adolescents with type 1 diabetes

Marques, Rosana de Morais Borges 10 November 2010 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2017-06-26T19:11:13Z No. of bitstreams: 2 Tese - Rosana de Morais Borges Marques - 2010.pdf: 1771939 bytes, checksum: 5fd48f948c945325a5833c92d6c978df (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Cláudia Bueno (claudiamoura18@gmail.com) on 2017-07-07T18:09:01Z (GMT) No. of bitstreams: 2 Tese - Rosana de Morais Borges Marques - 2010.pdf: 1771939 bytes, checksum: 5fd48f948c945325a5833c92d6c978df (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-07-07T18:09:01Z (GMT). No. of bitstreams: 2 Tese - Rosana de Morais Borges Marques - 2010.pdf: 1771939 bytes, checksum: 5fd48f948c945325a5833c92d6c978df (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2010-11-10 / The aim of the study was to asses the relative validity and the reproducibility of a quantitative food frequency questionnaire for epidemiologic studies with adolescents with type 1 diabetes. The participants were 70 adolescents of both sexes, regularly assisted at the endocrinology department of the Hospital das Clínicas from the Universidade Federal de Goiás and of the Hospital Geral de Goiânia. The socioeconomic status, demographic data, metabolic control, antropometry, physical activity and estimated energy requirement were evaluated. The food consupmtion was evaluated by the application of four 24-hour recalls, also used for the validation study. The reproducibility was evaluated by the comparison of the results obtained after two applications of the questionnaire. T test was aplied and Pearson correlation of energy-adjusted data was calculated and than corrected by intra personal variation. Agreement tests were also applied for validation and reproducibility. The adolescents presented an average of 14 years-old and an income of two salaries. More than 80% presented inadequate glycemic control that might be influenced by the caregiver's education and insulinic therapy. The diet was under the recommendations for carbohydrates and with high proportion of lipids. Most of the adolescents were sedentary or practiced light activity. The correlation coefficients obtained from the recalls and the questionnaires were as described by the literature, except for protein, which was inferior. The reproducibility of results showed good agreement. The questionnaire demosntrated acceptable capacity in measuring habitual consumption of adolescents with type 1 diabetes, being recommended as an instrument in clinic and epidemiologic studies with this population. / Este estudo objetivou avaliar a validade relativa e a reprodutibilidade de um questionário quantitativo de frequência alimentar para adolescentes portadores de diabetes tipo 1. Participaram do estudo 70 adolescentes, de ambos os sexos, regularmente atendidos nos ambulatórios de endocrinologia do Hospital das Clínicas da Universidade Federal de Goiás e do Hospital Geral de Goiânia. Os pacientes foram avaliados quanto aos aspectos socioeconômicos, demográficos, controle metabólico, antropometria, nível de atividade física e necessidade estimada de energia. O consumo alimentar foi avaliado por meio da aplicação de quatro recordatórios de 24 horas, cujos dados também foram utilizados para a validação do questionário. A avaliação da reprodutibilidade do questionário se deu pela comparação dos resultados obtidos após duas aplicações do instrumento. Aplicaram-se os testes t de student e de correlação de Pearson para dados ajustados pela energia e corrigidos pela variabilidade intrapessoal. Também foram aplicados testes de concordância para a validação e reprodutibilidade. Os adolescentes apresentaram média de idade de 14 anos e renda mensal per capita de até dois salários mínimos. Mais de 80% apresentaram controle glicêmico inadequado cujos resultados indicaram influência da escolaridade do cuidador e terapia insulínica. O consumo alimentar mostrou-se abaixo do recomendado para carboidratos e maior proporção de lipídios. A maioria dos adolescentes era sedentária ou praticava atividade leve. Os coeficientes de correlação obtidos entre os dados dos recordatórios e dos questionários variaram de 0,32 a 0,75, conforme os descritos na literatura. Os resultados da reprodutibilidade demonstraram boa concordância. Concluiu-se que o questionário apresentou aceitável capacidade em medir o consumo habitual dos adolescentes diabéticos tipo 1, sendo recomendado como instrumento em estudos clínicos e epidemiológicos com esta população.
138

Transtorno de déficit de atenção e hiperatividade em superdotados: um estudo de frequência de sintomas e alterações físicas menores / Attention deficit and hyperactivity disorder in intellectually gifted individuals: a study of frequency of symptoms and minor physical alterations

Daniel Minahim Araujo da Silva 16 January 2014 (has links)
INTRODUÇÃO: Os dados anteriores sobre a frequência de sintomas de TDAH na população de alto QI ainda são escassos e contraditórios, principalmente no topo da curva. OBJETIVO: Avaliar a frequência e o padrão de sintomas de TDAH em indivíduos superdotados durante dois momentos distintos do ciclo de vida, aplicando escalas padronizadas. Além disso, testamos se uma associação entre anomalias físicas menores e TDAH pode ser encontrada em adultos superdotados. MÉTODOS: Dois estudos transversais foram realizados em indivíduos previamente avaliados para QI com as Matrizes Progressivas de Raven: (1) Mensa: Este estudo incluiu 77 participantes adultos (22% mulheres) recrutados a partir dos registros de membros ativos da Mensa Brasil que vivem em São Paulo. A escala ASRS-18 e uma versão modificada da escala Waldrop para pequenas anomalias físicas foram aplicadas; (2) Colégio Objetivo: Foram incluídas todas as crianças do primeiro ao quinto ano do ensino fundamental (6-11 anos de idade) que estavam acima do percentil 99 para o QI (n = 39). O grupo controle incluiu 39 colegas de classe selecionados aleatoriamente entre aqueles abaixo do percentil 90 para QI pareados por idade e sexo. Os professores avaliaram os participantes usando o MTA-SNAP-IV. RESULTADOS: (1) Mensa: A frequência estimada do TDAH foi de 37,8 %. O número total de anomalias físicas menores foi significativamente associado com TDAH (p < 0,001) e 8 dos 36 sinais avaliados apresentaram esta associação individualmente (p < 0,05); (2) Colégio Objetivo: Obtivemos uma frequência de TDAH de 25,6% no grupo controle e 17,9% no grupo de indivíduos de alto QI (OR = 0,64, p = 0,58).CONCLUSÃO: Embora nossos dados não confirmem inequivocamente a maior prevalência de TDAH em indivíduos de alto QI durante o ciclo de vida, eles sugerem a validade do diagnóstico nesta população. Na população da Mensa, foi encontrada uma associação entre os casos de TDAH e anomalias físicas menores, apoiando ainda mais a noção de que o TDAH é um transtorno do neurodesenvolvimento / INTRODUCTION: Previous data on the frequency of symptoms of ADHD in high IQ population are still scarce and contradictory, especially at the top of the curve. OBJECTIVE: To evaluate the frequency and pattern of symptoms of ADHD in intellectually gifted individuals during two distinct moments of their life cycle, using standardized scales. In addition, we tested whether an association between minor physical anomalies and ADHD may be found in intellectually gifted adults. METHODS: Two cross-sectional studies were conducted in participants who had been previously evaluated for IQ\'s with Raven\'s Progressive Matrices: (1) Mensa: This study included 77 adult participants (22% women) recruited from the records of active members of Mensa Brazil living in São Paulo. The ASRS-18 and a modified version of Waldrop\'s scale for minor physical anomalies were applied; (2) Elementary school: All children from first to fifth year of elementary school (6-11 years old) who were above the 99th IQ percentile (n=39) were included. The control group included 39 classmates randomly selected among those below the 90th IQ percentile matched for age and sex. Teachers rated participants using MTA-SNAP-IV. RESULTS: (1) Mensa: The estimated frequency of ADHD was 37.8%. The total number of minor physical anomalies was significantly associated with ADHD (p < 0.001) and 8 of the 36 evaluated signs showed this association individually (p < 0.05). (2) Elementary school: A Rate of 25.6% of ADHD was found in the control group and 17.9% in the group of talented individuals (OR=0.64, p=0.58). CONCLUSION: Although our data do not unequivocally confirm the higher prevalence of ADHD in gifted individuals throughout their life cycles, they suggest the validity of the diagnosis in this population. An association between ADHD cases and minor physical anomalies was found in the Mensa population, further supporting the notion that ADHD is a neurodevelopmental condition
139

Using the Patient Health Questionnaire (PHQ-9) and the Edinburgh Postnatal Depression Scale (EPDS) to assess suicidal ideation among pregnant women in Lima, Peru.

Zhong, Qiu-Yue, Gelaye, Bizu, Sánchez, Sixto E, Simon, Gregory E, Henderson, David C, Barrios, Yasmin V, Sánchez, Pedro Mascaro, Williams, Michelle A, Rondón, Marta B. 12 1900 (has links)
We sought to examine the concordance of two suicidal ideation items from the Patient Health Questionnaire-9 (PHQ-9) and the Edinburgh Postnatal Depression Scale (EPDS), to evaluate the prevalence of suicidal ideation among pregnant women, and to assess the co-occurrence of suicidal ideation with antepartum depressive symptoms. A cross-sectional study was conducted among 1,517 pregnant women attending prenatal care clinics in Lima, Peru. Item 9 of the PHQ-9 assesses suicidal ideation over the last 14 days while item 10 of the EPDS assesses suicidal ideation in the past 7 days. The two suicidal ideation items have a high concordance rate (84.2 %) but a moderate agreement (the Cohen's kappa = 0.42). Based on the PHQ-9 and the EPDS, 15.8 and 8.8 % of participants screened positive for suicidal ideation, respectively. Assessed by the PHQ-9, 51 % of participants with suicidal ideation had probable depression. In prenatal care clinics, screening for suicidal ideation is needed for women with and without depressive symptoms. Future studies are needed to identify additional predictors of antepartum suicidality, determine the appropriate duration of reporting period for suicidal ideation screening, and assess the percentage of individuals with positive responses to the two suicidal ideation items at high risk of planning and attempting suicide. / This research was supported by an award from the National Institutes of Health (NIH), the Eunice Kennedy Shriver Institute of Child Health and Human Development (R01-HD-059835). The NIH had no further role in the study design; in the collection, analysis, and interpretation of data; in the writing of the report; and in the decision to submit the paper for publication. The authors wish to thank the dedicated staff members of Asociacion Civil Proyectos en Salud (PROESA), Peru and Instituto Especializado Materno Perinatal, Peru for their expert technical assistance with this research. The authors would like to thank Kathy Brenner for her help with revising this manuscript. / Revisión por pares
140

Psychometric Evaluation of Joint-Specific Patient-Reported Outcome Measures Before and After Total Knee Replacement: A Dissertation

Gandek, Barbara L. 23 September 2014 (has links)
Background: Patient reports of pain and function are used to inform the need for and timing of total knee replacement (TKR) and evaluate TKR outcomes. This dissertation compared measurement properties of commonly-used patient surveys in TKR and explored ways to develop more efficient knee-specific function measures. Methods: 1,179 FORCE-TJR patients (mean age=66.1, 61% female) completed questionnaires before and 6 months after TKR. Patient surveys included the knee-specific Knee injury and Osteoarthritis Outcome Score (KOOS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and generic SF-36 Health Survey. Tests of KOOS and WOMAC measurement properties included evaluations of scaling assumptions and reliability. Item response theory methods were used to calibrate 22 KOOS function items in one item bank; simulated computerized adaptive tests (CAT) then were used to evaluate shorter function scores customized for each patient. Validity and responsiveness of measures varying in attributes (knee-specific versus generic, longer versus shorter, CAT versus fixed-length) were compared. Results: KOOS and WOMAC scales generally met tests of scaling assumptions, although many pain items were equally strong measures of pain and physical function. Internal consistency reliability of KOOS and WOMAC scales exceeded minimum levels of 0.70 recommended for group-level comparisons across sociodemographic and clinical subgroups. Function items could be calibrated in one item bank. CAT simulations indicated that reliable knee-specific function scores could be estimated for most patients with a 55-86% reduction in respondent burden, but one-third could not achieve a reliable (≥ 0.95) CAT score post-TKR because the item bank did not include enough items vi measuring high function levels. KOOS and WOMAC scales were valid and responsive. Short function scales and CATs were as valid and responsive as longer KOOS and WOMAC function scales. The KOOS Quality of Life (QOL) scale and SF-36 Physical Component Summary discriminated best among groups evaluating themselves as improved, same or worse at 6 months. Conclusions: Results support use of the KOOS and WOMAC in TKR. Improved knee-specific function measures require new items that measure higher function levels. TKR outcomes should be evaluated with a knee-specific quality of life scale such as KOOS QOL, as well as knee-specific measures of pain and function and generic health measures.

Page generated in 0.1594 seconds