Determinação da PEEP ideal e avaliação de atelectasia pulmonar com o uso da ultrassonografia durante intraoperatório de cirurgias eletivas / Ideal PEEP and evaluation of pulmonary atelectasia with the use of ultrasonography during intraoperatory of elective surgeriesBruno Francisco de Freitas Tonelotto 03 December 2018 (has links)
Introdução: A atelectasia intraoperatória ocorre imediatamente após a indução anestésica e pode ser detectada por ultrassom pulmonar (LUS). No entanto, até o momento o LUS não é utilizado para avaliar a hiperdistensão pulmonar. Neste estudo, descreveu-se um método para detectar hiperdistensão pulmonar usando LUS. A tomografia de impedância elétrica (TIE) foi a referência para comparação dos métodos. Métodos: Dezoito (18) pacientes, com 63 ± 6 anos de idade, com pulmões normais, submetidos à cirurgia abdominal inferior. O TIE foi calibrado, realizada a indução anestésica, intubação e ventilação mecânica. Para reverter a atelectasia posterior, realizou-se uma manobra de recrutamento alveolar com o uso de pressão expiratória final positiva (PEEP) 20 cmH20 e pressão aérea do platô 40 cmH2O durante 120 segundos. A titulação PEEP foi então obtida com valores descendentes: 20, 18, 16, 14,12,10, 8, 6 e 4 cmH2O. Os dados de ultrassom e TIE foram coletados em cada nível PEEP e interpretados por dois observadores independentes. O número de linhas H foi contado usando um filtro especial. O teste de correlação de Spearman e a curva ROC foram utilizados para comparar os dados do LUS e TIE. Resultados: O número de linhas H aumentou linearmente com PEEP: de 3 em PEEP 4 cmH2O a 10 em PEEP 20 cmH2O. Cinco linhas H foram o limiar para a detecção de hiperdistensão pulmonar, definida como hiperdistensão na TIE >= 24,5%. A área sob a curva ROC foi 0,947 (IC 95% 0.901-0.976). Conclusão: O LUS intraoperatório detectou hiperdistensão pulmonar em valores descendentes de PEEP. A presença de cinco ou mais linhas H podem ser consideradas como indicando hiperdistensão pulmonar / Purpose: Intraoperative atelectasis occurs immediately after anaesthetic induction and can be detected by lung ultrasound (LUS). However, LUS is considered as unable to assess pulmonary hyperinflation. In this study, we propose a method to detect pulmonary hyperinflation using LUS. Electrical impedance tomography (EIT) was the reference method. Methods: We included 18 patients, 63 ± 6-year old, with normal lungs, undergoing lower abdominal surgery. The following protocol was used: EIT was calibrated, followed by anaesthetic induction, intubation and mechanical ventilation. To reverse posterior atelectasis, a recruitment maneuver - positive end-expiratory pressure (PEEP) 20 cmH20 and plateau airway pressure 40 cmH2O during 120 sec was performed. PEEP titration was then obtained during a descending trial: 20, 18, 16, 14,12,10, 8, 6 and 4 cmH2O. Ultrasound and EIT data were collected at each PEEP level and analyzed by two independent observers. The number of H lines was counted using a special filter. Spearman correlation test and ROC curve were used to compare LUS and EIT data. Results: The number of H lines increased linearly with PEEP: from 3 at PEEP 4 cmH2O to 10 at PEEP 20 cmH2O. Five H lines was the threshold for detecting pulmonary hyperinflation, defined as a mean decrease in maximum EIT compliance >= 24,5 %. The area under the ROC curve was 0.947 (CI 95% 0.901-0.976). Conclusion: Intraoperative transthoracic LUS can detect pulmonary hyperinflation during a PEEP descending trial. Five or more H lines can be considered as indicating pulmonary hyperinflation in normally aerated lung regions
|
62 |
Efeito da ventilação assistida proporcional na capacidade ao exercício em pacientes com fibrose pulmonar idiopática / Effects of proportional assist ventilation on exercise capacity in idiopathic pulmonary fibrosis patientsModerno, Eliana Vieira 29 March 2007 (has links)
O objetivo do presente estudo foi avaliar o efeito do suporte ventilatório com ventilação assistida proporcional (PAV) na capacidade ao exercício em pacientes com fibrose pulmonar idiopática (FPI). Dez pacientes foram submetidos a um teste cardiopulmonar de esforço máximo, prova de função pulmonar completa e 3 testes submáximos (60% da carga máxima): sem suporte ventilatório, com pressão positiva contínua nas vias aéreas (CPAP) e PAV. Foram avaliadas a capacidade de exercício, as adaptações cardiovasculares e ventilatórias e a percepção subjetiva de esforço. Uma amostra de lactato sanguíneo foi também obtida no repouso e no final do exercício. Nossos resultados mostram que a capacidade de exercício submáximo com suporte ventilatório PAV aumentou o tempo de exercício quando comparado com a CPAP e sem suporte ventilatório (respectivamente, 11,10±8,88 min, 5,60±4,74 e 4,50±3,84 min). O suporte ventilatório com PAV ocasionou uma menor demanda cardiovascular com redução do duplo produto e da freqüência cardíaca. Uma melhor oxigenação e uma menor percepção de esforço também foram observadas nos pacientes quando realizaram a atividade com PAV. Nossos resultados sugerem que o suporte ventilatório com PAV pode aumentar a tolerância ao exercício e reduzir a dispnéia em pacientes com fibrose pulmonar idiopática. / The objective of the present study was to evaluate the effect of ventilatory support using proportional assist ventilation (PAV) on exercise capacity in patients with idiopathic pulmonary fibrosis. Ten patients were submitted to a cardiopulmonary exercise testing, lung function and 3 submaximal exercise tests (60% of maximum load): without ventilatory support, with continuous positive airway pressure (CPAP) and PAV. Exercise capacity, cardiovascular and ventilatory adaptations and subjective perception to effort in lower limb and respiratory breathing were evaluated. Lactate plasmatic levels were obtained before and after submaximal exercise. Our results show that submaximal exercise capacity duration was increased with PAV compared with CPAP and without ventilatory support. (respectively, 11.10±8.88 min, 5.60±4.74 e 4.50±3.84 min). Ventilatory support with PAV lead to a lower cardiovascular demand such as double product and heart rate decreased. An improved arterial oxygenation and lower subjective perception to effort was also observed in patients with IPF when exercise was performed with PAV. Our results suggest that ventilatory support with PAV can increase exercise tolerance and decrease dyspnea in patients with idiopathic pulmonary fibrosis.
|
63 |
Eficácia e segurança do uso da ventilação não invasiva associada à manobra de recrutamento alveolar no pós-operatório de revascularização do miocárdio: ensaio clínico randomizado / Efficacy and safety of using noninvasive ventilation associated with recruitment maneuver in the postoperative period of coronary artery bypass grafting: a randomized clinical trialMieko Claudia Miura 21 November 2017 (has links)
INTRODUÇÃO: Complicações pulmonares são frequentes no pós-operatório da cirurgia de revascularização do miocárdio (RM) e a ventilação não-invasiva (VNI) tem sido utilizada nos cuidados pós-operatórios de forma profilática e terapêutica. A manobra de recrutamento alveolar (MRA) consiste no aumento sustentado de pressão na via aérea utilizando um alto nível de pressão expiratória final positiva (PEEP) em indivíduos hipoxêmicos, garantindo uma ventilação pulmonar homogênea e, com isso melhorando a oxigenação arterial. O objetivo desse estudo foi de avaliar se o uso da VNI associada à MRA pode melhorar a oxigenação e se pode ser aplicada de forma segura nos pacientes pós-operatório de RM. MÉTODOS: Foram incluídos 34 pacientes internados na unidade de terapia intensiva (UTI) ventilados mecanicamente após RM com relação Pa02/Fi02 < 300 e escore radiológico de atelectasia ;:: 2. Os pacientes foram randomizados 16 para o grupo controle (GC) e 18 para o grupo recrutamento (GR), após a extubação a VNI foi aplicada por 30 minutos três vezes ao dia de acordo com a rotina da UTI. No GC a VNI era realizada com PEEP de 8 cm H20 e no GR foi aplicada PEEP de 15 cm H20 e 20 cm H20 durante 2 minutos cada e depois ficava com PEEP de 8 cm H20. Analisamos a Pa02 pela gasometria arterial em ar ambiente e o escore radiológico de atelectasia, estabilidade hemodinâmica e evento adverso até a alta da UTI. RESULTADOS: Aumento de Pa02 12,6 ± 6,8% GC e 23,3 ± 8,5% GR com p < 0,001, o escore radiológico de atelectasia apresentou resolução completa em 94,4% GR, enquanto que no GC, 87,5% apresentou algum grau de atelectasia, p < 0,001. Não houve eventos adversos relacionados. CONCLUSÃO: o uso por 30 minutos da VNI associada à MRA foi seguro, melhorou a oxigenação e reduziu a atelectasia / BACKGROUND: Postoperative pulmonary impairment is common in the early period after coronary artery bypass grafting (CABG) and noninvasive ventilation (NIV) has been used in postoperative care to prevent and treatment. Recruitment maneuver (RM) consists in a sustained raise of airway pressure with high levei of positive end-expiratory pressure (PEEP) in hypoxemic subjects, insuring a homogeneous pulmonary ventilation and enhancing oxygenation. The aims of this study were to evaluate if the use of NIV associated with RM could improve oxygenation and if it could be safely applied in CABG postoperative patients. METHODS: Were included 34 patients admitled to the intensive care unit (ICU) mechanically ventilated after CABG with Pa02/Fi02 ratio < 300 and radiological atelectasis score (RAS) ~ 2. Patients were randomized 16 to the control group (CG) and 18 to the recruitment group (RG), after extubation NIV was applied for 30 minutes three times a day according to ICU routine. In the CG, NIV was performed with PEEP 8 cm H20 and in the RG, was applied PEEP 15 cm H20 and 20 cm H20 for 2 minutes each and then was with PEEP 8 cm H20. We analyzed Pa02 from arterial blood gas at room air and RAS, hemodynamic stability and adverse event until discharged from the ICU. RESUL TS: Increased of Pa02 12.6±6.8% CG and 23.3±8.5% RG p < 0,001, RAS presented complete improvement for 94.4% RG, whereas in the CG, 87.5% presented some degree of atelectasis, p < 0,001. There was no adverse event related. CONCLUSION: The use of 30 minutes of NIV associated with RM was safe, improved oxygenation and reduced atelectasis
|
64 |
Efeito da ventilação assistida proporcional na capacidade ao exercício em pacientes com fibrose pulmonar idiopática / Effects of proportional assist ventilation on exercise capacity in idiopathic pulmonary fibrosis patientsEliana Vieira Moderno 29 March 2007 (has links)
O objetivo do presente estudo foi avaliar o efeito do suporte ventilatório com ventilação assistida proporcional (PAV) na capacidade ao exercício em pacientes com fibrose pulmonar idiopática (FPI). Dez pacientes foram submetidos a um teste cardiopulmonar de esforço máximo, prova de função pulmonar completa e 3 testes submáximos (60% da carga máxima): sem suporte ventilatório, com pressão positiva contínua nas vias aéreas (CPAP) e PAV. Foram avaliadas a capacidade de exercício, as adaptações cardiovasculares e ventilatórias e a percepção subjetiva de esforço. Uma amostra de lactato sanguíneo foi também obtida no repouso e no final do exercício. Nossos resultados mostram que a capacidade de exercício submáximo com suporte ventilatório PAV aumentou o tempo de exercício quando comparado com a CPAP e sem suporte ventilatório (respectivamente, 11,10±8,88 min, 5,60±4,74 e 4,50±3,84 min). O suporte ventilatório com PAV ocasionou uma menor demanda cardiovascular com redução do duplo produto e da freqüência cardíaca. Uma melhor oxigenação e uma menor percepção de esforço também foram observadas nos pacientes quando realizaram a atividade com PAV. Nossos resultados sugerem que o suporte ventilatório com PAV pode aumentar a tolerância ao exercício e reduzir a dispnéia em pacientes com fibrose pulmonar idiopática. / The objective of the present study was to evaluate the effect of ventilatory support using proportional assist ventilation (PAV) on exercise capacity in patients with idiopathic pulmonary fibrosis. Ten patients were submitted to a cardiopulmonary exercise testing, lung function and 3 submaximal exercise tests (60% of maximum load): without ventilatory support, with continuous positive airway pressure (CPAP) and PAV. Exercise capacity, cardiovascular and ventilatory adaptations and subjective perception to effort in lower limb and respiratory breathing were evaluated. Lactate plasmatic levels were obtained before and after submaximal exercise. Our results show that submaximal exercise capacity duration was increased with PAV compared with CPAP and without ventilatory support. (respectively, 11.10±8.88 min, 5.60±4.74 e 4.50±3.84 min). Ventilatory support with PAV lead to a lower cardiovascular demand such as double product and heart rate decreased. An improved arterial oxygenation and lower subjective perception to effort was also observed in patients with IPF when exercise was performed with PAV. Our results suggest that ventilatory support with PAV can increase exercise tolerance and decrease dyspnea in patients with idiopathic pulmonary fibrosis.
|
65 |
Efeitos interativos da pressão expiratória final positiva (PEEP) e da fração inspirada de oxigênio (FIO2) no colapso pulmonar durante anestesia geral em modelo experimental suíno / Interactive effects of positive-end expiratory pressure (PEEP) and fraction of inspired oxygen (FIO2) on pulmonary collapse during general anesthesia in experimental swine modelJosé Renato de Melo 25 October 2017 (has links)
INTRODUÇÃO: O desenvolvimento de colapso pulmonar (atelectasia) durante anestesia geral com ventilação mecânica é frequente, podendo determinar hipoxemia e contribuir para desenvolvimento de outras complicações pós-operatórias, como infecção e síndrome do desconforto respiratório agudo (SDRA). O uso de fração inspirada de oxigênio (FIO2) baixa e de pressão expiratória final positiva (PEEP) podem reduzir a quantidade de pulmão atelectasiado. Existem poucos dados experimentais sobre a cinética do desenvolvimento da atelectasia no intraoperatório em diferentes ajustes de FIO2 e PEEP no decorrer do tempo. A Tomografia de impedância elétrica (TIE) do tórax permite uma análise contínua e não invasiva da função pulmonar, bem como da quantificação do colapso e pode ser usada no intraoperatório. OBJETIVOS: a) avaliar, em animais com pulmões sadios durante anestesia geral, o efeito do uso de uma PEEP individualizada escolhida através da TIE (\"PEEP titulada\"), na formação de colapso; b) analisar a magnitude e a cinética de desenvolvimento do colapso pulmonar no decorrer do período de uma hora em dois valores de FIO2 (0,4 e 1) e dois valores de PEEP (3 cmH2O e valor da PEEP titulada) através da TIE e Tomografia computadorizada (TC); c) analisar mecânica, ventilação regional e aeração pela TIE e troca gasosa nos diferentes períodos do estudo. MÉTODOS: Nove animais (suínos) com pulmão normal foram submetidos à manobra de titulação da PEEP para escolha da PEEP que determina colapso pulmonar mínimo (colapso menor que 3% determinado pela TIE, denominada \"PEEP titulada\") e posteriormente ventilados com volume corrente de 6ml/Kg em quatro ajustes, em sequência randomizada, por um período de 1 hora: FIO2 0,4 e PEEP 3, FIO2 0,4 e PEEP titulada, FIO2 1 e PEEP 3 e FIO2 1 e PEEP titulada. O colapso, ventilação regional e aeração foram medidos continuamente, através da TIE assim como dados da mecânica. Mensuramos troca gasosa e aeração pulmonar pela TC em 3 momentos em cada período do estudo (baseline, 5 e 50 minutos). RESULTADOS: A PEEP titulada foi de 11,6 ±1,4 cm H2O. Houve colapso progressivo no decorrer do tempo nos 4 grupos estudados tendo sido maior na PEEP 3 que na PEEP titulada. A medida do colapso pela TIE não foi influenciada pela FIO2 utilizada, ao contrário da mensuração pela TC na qual o colapso foi maior na FIO2 de 1. Houve queda da complacência pulmonar e aumento da pressão de distensão no decorrer do tempo, maiores na PEEP 3, sem influência da FIO2. Na região dorsal, a TIE evidenciou redução da ventilação (delta Z) na PEEP 3, sem influência da FIO2, e, também, redução da aeração (mínimo Z) que foi maior na PEEP 3 e na FIO2 de 1. Houve queda da relação PaO2/FIO2 e aumento do shunt e mistura venosa na PEEP 3. Não houve alterações hemodinâmicas clinicamente relevantes durante o estudo. CONCLUSÕES: Houve colapso progressivo no decorrer do tempo, sendo maior na PEEP 3 que na PEEP titulada. O colapso aferido pela TC foi maior na FIO2 de 1 do que na 0,4 para uma mesma PEEP, diferente da TIE cuja estimativa de colapso não foi diferente. Paralelamente houve queda da complacência pulmonar, aumento da pressão de distensão e redução da ventilação dorsal, maiores na PEEP 3 e sem influência da FIO2. A queda da aeração estimada pela TIE foi maior na PEEP 3, sendo que nas duas PEEP a aeração foi menor na FIO2 de 1 / INTRODUCTION: The development of pulmonary collapse (atelectasis) during general anesthesia with mechanical ventilation is frequent, which can determine hypoxemia and contribute to the development of other postoperative complications, such as infection and acute respiratory distress syndrome (ARDS). The use of low fraction of inspired oxygen (FIO2) and positive end expiratory pressure (PEEP) may reduce the amount of collapsed lung. There are few experimental data on the kinetics of intraoperative atelectasis development in different FIO2 and PEEP adjustments over time. Electrical impedance tomography (EIT) of the thorax allows a continuous and noninvasive analysis of pulmonary function as well as the quantification of pulmonary atelectasis and can be used intraoperatively. OBJECTIVES: a) to evaluate, in animals with healthy lungs during general anesthesia, the effect of the use of an individualized PEEP chosen through EIT (titrated PEEP), in the formation of collapse; b) to analyze the magnitude and development kinetics of pulmonary collapse during the one-hour period in two values of FIO2 (0.4 and 1) and two PEEP values (3 cmH2O and titrated PEEP value) through EIT and computed tomography (CT); c) to analyze mechanics, regional ventilation and aeration by EIT and gas exchange in the different periods of the study. METHODS: Nine animals (swine) with normal lung were submitted to a PEEP titration maneuver to select PEEP that determines minimal pulmonary collapse (collapse of less than 3% determined by EIT, called \"titrated PEEP\") and then ventilated with a tidal volume of 6ml / kg in four adjustments, in a randomized sequence, for a period of 1 hour: FIO2 0.4 and PEEP 3, FIO2 0.4 and titrated PEEP, FIO2 1 and PEEP 3 and FIO2 1 and titrated PEEP. The collapse, regional ventilation and aeration were measured continuously through EIT as well as mechanics data. We also measured gas exchange and aeration by CT at 3 times in each study period (baseline, 5 e 50 minutes). RESULTS: The titrated PEEP was 11.6 ±1.4 cm H2O. There was a progressive collapse over time in the 4 groups studied, having been higher in PEEP 3 than in titrated PEEP. The measurement of EIT collapse was not influenced by the FIO2 used, as opposed to the CT measurement in which the collapse was greater in the FIO2 1. There was a decrease in pulmonary compliance and an increase in drive pressure over time, higher in PEEP 3, without influence of FIO2. In the dorsal region, EIT showed a decrease in ventilation, as measured by delta Z, in PEEP 3, with no influence of FIO2; there was also reduction of aeration, measured by the minimum Z, higher in PEEP 3 and FIO2 of 1. There was a decrease in the PaO2 / FIO2 ratio and increased in shunt and venous admixture in PEEP 3. There was no clinically relevant change in hemodynamics during the study. CONCLUSIONS: There was a greater collapse in PEEP 3 than in titrated PEEP over time. Collapse measured by CT was higher in FIO2 of 1 than 0.4 for the same PEEP, different from EIT estimates of collapse which was not different. Beside the collapse, there were decrease in compliance, increase in driving pressure and reduction of dorsal ventilation, higher in PEEP 3 without FIO2 influence. The decrease of aeration estimated by EIT was higher in PEEP 3 and for both PEEP values aeration was lower with FIO2 of 1
|
66 |
Estudo tomográfico de pressões de colapso alveolar e níveis isogravitacionais em pulmões de pacientes com SDRA e LPA / Tomographic study of alveolar collapsing pressures and isogravitational levels and in the lungs of patients with ARDS and/or ALIDash, Shari Anne Ahmed El 12 January 2009 (has links)
Estudo clínico prospectivo, em 11 pacientes com SARA ou LPA, avaliando o comportamento regional da densidade do tecido pulmonar e do colapso alveolar ao longo dos três eixos do espaço. Foram realizadas tomografias seriadas, após manobra de recrutamento inicial e após níveis de PEEP progressivamente decrescentes. Regressão linear múltipla (R2=0.83) mostrou importante gradiente no eixo gravitacional (p<0.001) e não no sentido céfalo-caudal (p<0.001), nem da direita para a esquerda (p<0.05). Isto corrobora o conceito do pulmão líquido, em que a resultante das pressões exercidas pelo diafragma, estruturas mediastinais e derrames seria transmitida uniformemente pelo tecido pulmonar. Cada um destes níveis isogravitacionais tem uma pressão crítica de fechamento (Pclosing), que é maior do que a pressão superimposta calculada. PEEP tem um efeito homogeneizador sobre o parênquima pulmonar. Dentre os parâmetros clínicos estudados, Pflex mostrou a pior correlação com colapso pulmonar documentado enquanto PO2 e a complacência máxima se mostraram equivalentes. / A prospective clinical study performed on 11 patients with ARDS or ALI with the intention of studying the regional behavior of lung tissue density and alveolar collapse along the three spatial axes. An initial recruitment maneuver was followed by multiple semi-complete CT scans at descending levels of PEEP. Multiple linear regression (R2=0.83) showed a gravitational gradient of densities and collapse (p<0.001) and no cephalo-caudal (p<0.001) or right-toleft increase (p<0.05), corroborating the liquid-like behavior of the lung. Pressure exerted by mediastinal structures, chest wall and effusions is transmitted uniformly throughout the lung. PEEP has a homogenizing effect on lung parenchyma. Among commonly used clinical surrogates, Pflex showed the worst correlation with actual lung collapse, while arterial PO2 and compliance were equivalent.
|
67 |
Efeitos da ventilação mecânica não-invasiva na variabilidade da freqüência cardíaca e no padrão ventilatório de pacientes submetidos à cirurgia de revascularização do miocárdioPantoni, Camila Bianca Falasco 26 June 2009 (has links)
Made available in DSpace on 2016-06-02T20:19:11Z (GMT). No. of bitstreams: 1
2553.pdf: 1596497 bytes, checksum: 1c1b091ddb6a8fb9d0cc5e1b5bfd8201 (MD5)
Previous issue date: 2009-06-26 / Universidade Federal de Minas Gerais / Noninvasive positive pressure ventilation (NIPPV) has been commonly applied in several clinical and postoperative conditions, especially after coronary artery bypass grafting (CABG) surgery and it can cause breathing pattern (BP) alterations and mechanical effects on cardiovascular system, with cardiac autonomic adjustments. However, it is not well established in the literature how these alterations occur in
patients submitted to the CABG and if they can be related to the application of different positive airway pressure levels. In this context, we considered the development of two studies that could contribute with new information about these topics. The first study is entitled Acute application of bilevel positive airway pressure influence cardiac autonomic nervous system and its objective was to evaluate the changes in heart rate variability (HRV) during bilevel positive airway pressure (Bilevel) application in healthy young men. Twenty men underwent a 10-min register of R-R intervals (R-Ri) during sham ventilation, Bilevel 8-15cmH2O and Bilevel 13-20 cmH2O. HRV was analyzed in time and frequency-domain and with non-linear statistical measures. Physiological variables (blood pressure, breathing rate, end tidal carbon dioxide- ETCO2) were also collected. R-Ri mean, rMSSD, NN50, pNN50 and SD1 reduced during 13-20 cmH2O compared to sham ventilation, with reduction of the R-Ri mean compared to 8-15 cmH2O. R-Ri mean and high frequency band (HF) reduced and low frequency band (LF) increased during 8-15 cmH2O compared to sham ventilation. Delta of ETCO2 correlated positively with LF, HF, LF/HF, SDNN, rMSSD and SD1. In conclusion, acute application of Bilevel was able to alter cardiac autonomic nervous system, with parasympathetic activity reduction and sympathetic increase and higher level of positive airway pressure can cause a greater influence
on the cardiovascular and respiratory system. The second study is entitled The effects of different levels of positive airway pressure on respiratory pattern and heart rate variability in patients submitted to coronary artery bypass grafting surgery and its objective was to access the effects of different levels of continuous positive airway pressure (CPAP) in BP and HRV in CABG postoperative (PO), as well as the impact of CABG in these variables. Eighteen patients underwent CABG was evaluated during spontaneous breathing (SB) and four different CPAP levels of CPAP, in a random order: (a) CPAP = sham (3 cmH2O), (b) 5 CPAP = cmH2O, (c) 8 CPAP= cmH2O, (d) 12 CPAP = cmH2O in PO. HRV was analysed in time and frequency domain and by non-linear methods (Poincaré plot e Detrended Fluctuation Analysis)
and BP was analysed by inductive respiratory plethysmograph. There were significant alterations of HRV and BP in the PO of CRM, compared to pre-operative and alterations of DFAα1, DFAα2 e SD2 and respiratory variables during NIPPV, with
higher influence observed during application of the two higher levels applied. Moreover, there was relationship between DFAα1 and inspiratory time of delta 12 cmH2O and SB, and 8 cmH2O and SB. In conclusion, acute CPAP application was able to alter the control of cardiac autonomic nervous system and BP of patients submitted to CABG and higher levels promoted better performance of pulmonary and cardiac autonomic function. / A ventilação não-invasiva por pressão positiva (VNIPP) tem sido comumente utilizada em diversas condições clínicas e pós-operatórias, principalmente na cirurgia de revascularização do miocárdio (CRM) e pode causar alterações do padrão ventilatório (PV) e efeitos mecânicos sobre o sistema cardiovascular, com ajustes autonômicos cardíacos. Entretanto, ainda não é claro se estas alterações
ocorrem em pacientes submetidos à CRM e se podem estar relacionadas a diferentes níveis pressóricos aplicados. Neste contexto, propusemos o desenvolvimento de dois estudos que poderiam contribuir com novas informações. O primeiro estudo, intitulado Aplicação aguda de pressão positiva por dois níveis pressóricos nas vias aéreas influencia o sistema nervoso autonômico cardíaco teve por objetivo avaliar as mudanças na variabilidade da frequência cardíaca (VFC)
durante aplicação de pressão positiva por dois níveis pressóricos (Bilevel) em indivíduos jovens saudáveis. Vinte homens foram submetidos ao registro de 10 minutos dos intervalos R-R (iR-R) durante aplicação de ventilação sham, Bilevel 8- 15cmH2O e Bilevel 13-20 cmH2O. A VFC foi analisada no domínio do tempo e da freqüência e por métodos não-lineares. Variáveis fisiológicas (pressão arterial, frequência respiratória e fração de dióxido de carbono no final da expiração- ETCO2) também foram coletadas. Houve redução da média dos iR-R, e dos índices rMSSD, NN50, pNN50 e SD1 durante aplicação dos níveis 13-20 cmH2O de Bilevel comparado ao modo sham, ainda com redução da média dos iR-R quando comparados aos níveis 8-15cmH2O. Houve diminuição da média dos iR-R e da banda de alta freqüência (AF), com aumento da banda de baixa freqüência (BF) durante a aplicação de 8-15 cmH2O comparada à ventilação sham. O delta de ETCO2 correlacionou-se positivamente com BF, AF, BF/AF, SDNN, rMSSD e SD1.
Em conclusão, a aplicação aguda de Bilevel foi capaz de alterar o sistema nervoso autonômico cardíaco, com redução da atividade parassimpática e aumento da atividade simpática e níveis mais elevados de pressão positiva podem causar maior
influência nos sistemas cardiovascular e respiratório. O segundo estudo, intitulado Efeitos de diferentes níveis de pressão positiva nas vias aéreas sobre o padrão ventilatório e a variabilidade da freqüência cardíaca de pacientes submetidos à cirurgia de revascularização do miocárdio objetivou avaliar os efeitos da aplicação de diferentes níveis de pressão positiva contínua nas vias aéreas (CPAP) sobre o
padrão ventilatório (PV) e a VFC no pós-operatório (PO) de CRM, bem como o impacto da CRM sobre estas variáveis. Foram avaliados 18 pacientes submetidos à CRM, durante RE (respiração espontânea) e aplicação de quatro níveis de CPAP,
de forma randomizada: (a) CPAP = sham (3 cmH2O), (b) CPAP = 5 cmH2O, (c) CPAP= 8 cmH2O, (d) CPAP = 12 cmH2O no PO. A VFC foi analisada no domínio do tempo e da freqüência e por métodos não-lineares (Poincaré plot e Flutuações
Depuradas de Tendência) e o PV foi analisado em diferentes variáveis, por meio da pletismografia respiratória por indutância. Houve alteração da VFC e do PV no PO de CRM, comparado ao período pré-operatório, bem como alterações dos índices DFAα1, DFAα2 e SD2, e de variáveis ventilatórias durante aplicação de VNIPP, com maior influência exercida pela aplicação dos dois níveis pressóricos mais elevados.
Além disso, houve correlação entre o índice DFAα1 e tempo inspiratório para o delta de 12 cmH2O e RE, e 8 cmH2O e RE. Em conclusão, temos que a aplicação aguda de CPAP foi capaz de alterar o controle do sistema nervoso autonômico cardíaco e o PV de pacientes submetidos à CRM e os níveis mais elevados promoveram melhor desempenho da função pulmonar e autonômica cardíaca. Apoio Financeiro: FAPESP (07/53202-9).
|
68 |
Estudo tomográfico de pressões de colapso alveolar e níveis isogravitacionais em pulmões de pacientes com SDRA e LPA / Tomographic study of alveolar collapsing pressures and isogravitational levels and in the lungs of patients with ARDS and/or ALIShari Anne Ahmed El Dash 12 January 2009 (has links)
Estudo clínico prospectivo, em 11 pacientes com SARA ou LPA, avaliando o comportamento regional da densidade do tecido pulmonar e do colapso alveolar ao longo dos três eixos do espaço. Foram realizadas tomografias seriadas, após manobra de recrutamento inicial e após níveis de PEEP progressivamente decrescentes. Regressão linear múltipla (R2=0.83) mostrou importante gradiente no eixo gravitacional (p<0.001) e não no sentido céfalo-caudal (p<0.001), nem da direita para a esquerda (p<0.05). Isto corrobora o conceito do pulmão líquido, em que a resultante das pressões exercidas pelo diafragma, estruturas mediastinais e derrames seria transmitida uniformemente pelo tecido pulmonar. Cada um destes níveis isogravitacionais tem uma pressão crítica de fechamento (Pclosing), que é maior do que a pressão superimposta calculada. PEEP tem um efeito homogeneizador sobre o parênquima pulmonar. Dentre os parâmetros clínicos estudados, Pflex mostrou a pior correlação com colapso pulmonar documentado enquanto PO2 e a complacência máxima se mostraram equivalentes. / A prospective clinical study performed on 11 patients with ARDS or ALI with the intention of studying the regional behavior of lung tissue density and alveolar collapse along the three spatial axes. An initial recruitment maneuver was followed by multiple semi-complete CT scans at descending levels of PEEP. Multiple linear regression (R2=0.83) showed a gravitational gradient of densities and collapse (p<0.001) and no cephalo-caudal (p<0.001) or right-toleft increase (p<0.05), corroborating the liquid-like behavior of the lung. Pressure exerted by mediastinal structures, chest wall and effusions is transmitted uniformly throughout the lung. PEEP has a homogenizing effect on lung parenchyma. Among commonly used clinical surrogates, Pflex showed the worst correlation with actual lung collapse, while arterial PO2 and compliance were equivalent.
|
69 |
Efeitos da ventilação mecânica e pressão positiva no final da expiração sobre a microcirculação mesentérica em ratos Wistar / Effects of mechanical ventilation and positive end-expiratory pressure on mesenteric microcirculation in Wistar ratsPriscila Aikawa 03 September 2009 (has links)
Ventilação mecânica (MV) com pressão positiva no final da expiração (PEEP) melhora a oxigenação sanguínea e oferta de oxigênio aos tecidos no tratamento da insuficiência respiratória aguda. No entanto, a pressão intratorácica elevada pode alterar o fluxo sanguíneo no mesentério que pode contribuir para complicações gastrointestinais durante a VM. Investigamos os efeitos da PEEP sobre as interações leucócito-endotélio durante a VM em ratos com pulmões normais e sem administração de fluido (Fase I) e os efeitos do volume corrente baixo (LTV) e pentoxifilina (PTX) sobre a microcirculação mesentérica (Fase II). O protocolo e resultados da Fase I são os seguintes: 44 ratos Wistar machos (~240g) foram anestesiados com pentobarbital (I.P., 50mg.kg-1) e com isoflurane inalatório (1.5-2%) após instrumentação, e aleatoriamente divididos em (1) INTACTO (somente anestesia), (2) PEEP0 (PEEP=0 cmH2O), (3) PEEP5 (PEEP=5 cmH2O), e (4) PEEP10 (PEEP=10 cmH2O). Os grupos PEEP foram submetidos à traqueostomia e VM com volume corrente de 10 ml.kg-1, frequência respiratória de 70 rpm e fração inspirada de oxigênio de 1. Após 2-h de VM, realizamos laparotomia mediana e avaliamos as interações leucócito-endotélio por meio de microscopia intravital e inflamação pumonar por meios histológicos. Não observamos alterações significantes na pressão sanguínea arterial média (PAM) entre os grupos ao longo do estudo. A pressão traqueal do grupo PEEP5 foi menor comparada com os grupos PEEP0 e PEEP10 (11, 15, e 16 cmH2O, respectivamente; p<0.05). Após 2-h de VM, não houve diferenças significantes entre os grupos INTACTO, PEEP0 e PEEP5 no número de leucócitos rollers (118±9, 127±14 e 147±26 células/10minutos, respectivamente), aderidos (3±1, 3±1 e 4±2 células/100m de comprimento de vênula, respectivamente), e migrados (2±1, 2±1 e 2±1 células/5,000m2, respectivamente) no mesentério. No entanto, PEEP10 aumentaram (p<0.05) o número de leucócitos rollers (188±15 células/10minutos), aderidos (8±1 células/100m de vênula) e migrados (12±1 células/5,000 m2). Observamos inflamação pulmonar nos grupos PEEP0 e PEEP10. O protocolo e resultados da Fase II são os seguintes: 57 ratos Wistar machos (~253g) foram anestesiados com pentobarbital (I.P., 50 mg.kg-1), submetidos a traqueostomia, anestesia inalatória com isoflurane (1.5-2%), VM com PEEP de 10 cmH2O, fração inspirada de oxigênio de 0,21, e aleatoriamente divididos em (1) LTV (7 ml.kg-1), (2) volume corrente elevado (HTV, 10 ml.kg-1), e (3) PTX (HTV+ PTX, 25 mg.kg-1). Nós registramos a PAM, mecânica respiratória e gases sanguíneos arteriais no basal e após 2-h de VM. Realizamos laparotomia mediana e avaliamos as interações leucócito-endotélio no mesentério, fluxo de artéria mesentérica (FAM), mecânica respiratória e inflamação pulmonar. Não observamos diferenças entre os grupos no basal e após 2-h em PAM (113±15 vs 109± 6 mmHg). Após 2-h de VM, o FAM foi similar em todos os grupos (12.4±2.6 ml.min-1). A pressão traqueal foi menor no grupo LTV (11.2±1.6 cmH2O) comparada com HTV (14.7±1.1 cmH2O) e PTX (14.1±2.4 cmH2O). Em todos os grupos a VM aumentou a elastância pulmonar (~22%, p<0.05) e diminuiu a resistência de vias aéreas (~10%, p<0.05). LTV e PTX apresentaram valores similares de leucócitos aderidos (5±2 e 6±4 células/100m de vênula, respectivamente), e migrados (1±1 e 2±1 células/5,000m2, respectivamente). Contrariamente, HTV aumentou o número de aderidos (14±4 leucócitos/100m de vênula, p<0.05) e migrados (9±3 células/5,000m2, p<0.05) no mesentério. O grupo HTV apresentou infiltrado neutrofílico e edema pulmonar. Em conclusão, nosso estudo mostrou que a pressão intratorácica elevada é prejudicial para a microcirculação mesentérica e pulmões no modelo experimental de ratos com pulmões normais e pressão sanguínea sistêmica estável, LTV previne alterações microcirculatórias e pulmonares, e a administração precoce de PTX atenua as interações leucócito-endotélio no mesentério e inflamação pulmonar durante a VM. Esses achados podem ter relevância na compreensão das complicações induzidas pela VM e prognóstico. / Mechanical ventilation (MV) with positive end expiratory pressure (PEEP) improves blood oxygenation and tissue oxygen delivery during treatment of acute respiratory failure. However, high intrathoracic pressure may alter blood flow at mesentery, which may contribute to gastrointestinal complications during MV. We investigated the effects of PEEP on mesenteric leukocyte-endothelial interactions during MV in rats with normal lungs and without fluid administration (Phase I) and the effects of low-tidal volume (LTV) and pentoxifylline (PTX) on mesenteric microcirculation (Phase II). The protocol and results of Phase I are the following: 44 male Wistar rats (~240g) were anesthetized with pentobarbital (I.P., 50mg.kg-1) and inhaled isoflurane (1.5-2%) after instrumentation, and randomly divided in (1)NAIVE (only anesthesia), (2) PEEP0 (PEEP=0 cm H2O), (3) PEEP5 (PEEP=5 cmH2O), and (4) PEEP10 (PEEP=10 cmH2O). PEEP groups were submitted to tracheostomy and MV with tidal volume of 10 ml.kg-1, respiratory rate of 70 rpm and inspired oxygen fraction of 1. After 2-hrs of MV, we performed a median laparotomy and evaluated leukocyte-endothelial interactions at the mesentery and lung inflammation by histology. We did not observe significant changes mean arterial blood pressure (MABP) among groups throughout the study. Tracheal pressure in PEEP5 was lower compared with PEEP0 and PEEP10 groups (11, 15, and 16 cmH2O, respectively; p<0.05). After 2-hrs of MV, there were no differences among NAIVE, PEEP0 e PEEP5 groups in the number of rollers (118±9, 127±14 and 147±26 cells/10 minutes, respectively), adherent leukocytes (3±1, 3±1 and 4±2 cells/100 m venule, respectively), and migrated leukocytes (2±1, 2±1 and 2±1 cells/5,000 m2, respectively) at the mesentery. However, PEEP10 increased (p<0.05) the number of rolling (188±15 cells/10min), adherent (8±1 cells/100 m) and migrated leukocytes (12±1 cells/5,000 m2). We observed lung inflammation in PEEP0 and PEEP10 groups. The protocol and results of Phase II are the following: 57 male Wistar rats (~253g) were anesthetized with pentobarbital (I.P.,50 mg.kg-1), submitted to tracheostomy, inhaled anesthesia with isoflurane (1.5-2%), MV with PEEP of 10 cmH2O, inspired oxygen fraction of 0.21, and randomly divided in (1) LTV (7 ml.kg-1), (2) High-tidal volume (HTV, 10 ml.kg-1), and (3) PTX (HTV+ PTX, 25 mg.kg-1). We registered MABP, respiratory mechanics and arterial blood gases at baseline and after 2-hrs of MV. We performed a median laparotomy and evaluated leukocyte-endothelial interactions, mesenteric artery flow (MAF), respiratory mechanics and lung inflammation. We did not observe significant differences among groups at baseline and after 2-hrs in MABP (113±15 vs 109± 6 mmHg). After 2-hrs, MAF was similar in all groups (12.4±2.6 ml.min-1). Tracheal pressure was lower in LTV (11.2±1.6 cmH2O) compared with HTV (14.7±1.1 cmH2O) and PTX (14.1±2.4 cmH2O). In all groups MV increased pulmonary elastance (22%, p<0.05) and decreased airway resistance (10%, p<0.05). LTV and PTX presented similar values of adherent (5±2 and 6±4 cells/100m venule, respectively), and migrated leukocytes (1±1 and 2±1 cells/5,000m2, respectively). On the contrary, HTV increased the number of adherent (14±4 leukocytes/100m venule, p<0.05) and migrated leukocytes (9±3 cells/5,000m2, p<0.05) in the mesentery. HTV presented lung neutrophil infiltration and edema. In conclusion, our study showed that high intrathoracic pressure is harmful to mesenteric microcirculation and lungs in the experimental model of rats with normal lungs and stable systemic blood pressure, LTV prevents microcirculatory and pulmonary alterations, and early administration of PTX attenuates leukocyte-endothelial interactions at the mesentery and lung inflammation during MV. These findings may have relevance for complications MV-induced and outcome.
|
70 |
Efeitos cardiovasculares das manobras de recrutamento alveolar durante lesão pulmonar aguda por ácido clorídrico: estudo experimental em suínos / Cardiovascular effects of alveolar recruitment maneuvers during acute lung injury by hydrochloric acid: experimental study in pigsMarumo, Cristina Keiko 14 June 2007 (has links)
INTRODUÇÃO: Colapso alveolar é achado freqüente em lesão pulmonar aguda (LPA), levando ao aumento do shunt intrapulmonar e hipoxemia. Estratégias de tratamento atuais visam o recrutamento alveolar para melhora das trocas gasosas. Embora as manobras de recrutamento alveolar (MRA) sejam objetos de investigação nas últimas duas décadas, seu uso tem se tornado mais freqüente para o tratamento de pacientes com LPA. Volumes pulmonares e pressões pleurais elevados associados a MRA podem afetar a resistência vascular pulmonar e o trabalho cardíaco negativamente. Porém, o benefício da MRA na oxigenação, perante seus efeitos hemodinâmicos negativos, permanecem incertos devido à falta de informações dos efeitos cardiovasculares das MRAs. O objetivo deste estudo foi verificar, em modelo de LPA, os efeitos de um tipo de MRA- insuflação sustentada- associada a diferentes valores de PEEP no sistema cardiovascular durante um determinado período de observação. TIPO DE ESTUDO: estudo experimental prospectivo, controlado e randomizado. LOCAL: Laboratório de Anestesiologia Experimental- LIM 08. MATERIAL: Trinta e dois animais suínos. MÉTODO: Os animais anestesiados foram ventilados em modo volume-controlado e randomizados em quatro grupos (G1-PEEP; G2-PEEP-MRA; G3-LPA-PEEP; G4-LPA-PEEP-MRA) com oito animais cada. Os valores de PEEP foram progressivamente aumentados e diminuídos (5, 10, 15 e 20 cmH2O) em todos os animais e eram mantidos inalterados por 20 minutos em cada valor. Três insuflações sustentadas (MRA) de 30 cmH2O com duração de 20 segundos cada foram aplicadas em cada valor de PEEP nos grupos G2-PEEP-MRA e G4-LPA-PEEP-MRA. Para indução da LPA, principalmente em regiões pulmonares dependentes, o ácido clorídrico (0.05N, 4mL/kg) foi instilado na traquéia por meio de broncofibroscópio nos grupos G3-LPA-PEEP e G4-LPA-PEEP-MRA. Ecocardiografia transesofágica, saturação venosa mista (SVO2), débito cardíaco por termodiluição intermitente e contínuo, pressões pulmonares e sistêmicas, transporte e consumo de oxigênio, tonometria gástrica e índices metabólicos foram medidos em determinados tempos. RESULTADOS : A manobra de recrutamento tipo insuflação sustentada não causou efeitos negativos cardiovasculares adicionais durante as 3 horas de protocolo. Indepedentemente da lesão pulmonar, durante o aumento progressivo de PEEP foi observado uma redução significativa (p<0.001) do índice cardíaco durante PEEP de 10 cmH2O (11.8 +- 7.4%), 15 cmH2O(25.5 +- 5.7%) e 20 cmH2O (36.1+- 5.1%), acompanhados de uma significativa redução da saturação venosa de oxigênio (p<0.001) durante PEEP de 15 e 20 cmH2O. Ao mesmo tempo, os volumes diastólicos finais dos ventrículos direito (VD) e esquerdo (VE) foram significativamente reduzidos durante PEEP de 10, 15 e 20 cmH2O (p<0.001) e durante PEEP de 20 cmH2O (p<0.001) respectivamente. A fração de ejeção do VD mostrou diminuição significativa durante PEEP de 10 cmH2O (p<0.05), 15 e 20 cmH2O (p<0.001) enquanto a fração de ejeção do VE permaneceu inalterada. O transporte de oxigênio foi significativamente reduzido (p<0.05) durante PEEP de 15 e 20 cmH2O, acompanhado por elevação da taxa de extração de oxigênio (p<0.001), sem comprometimento do consumo de oxigênio, lactato arterial sérico e tonometria gástrica. CONCLUSÕES: A instilação pulmonar de ácido clorídrico causou LPA caracterizada por queda na relação paO2/ FiO2, diminuição da complacência e hipertensão pulmonar. As insuflações sustentadas não causaram efeitos deletérios ao sistema cardiovascular durante as 3 horas de protocolo independentemente da presença de LPA. Os efeitos cardiovasculares negativos observados neste estudo foram resultantes do incremento de PEEP. Não houve diferença quanto aos efeitos cardiovasculares relacionados à PEEP entre os grupos. / INTRODUCTION: Alveolar collapse is a common finding in acute lung injury (ALI), leading to increased shunt and hypoxemia. Current treatment strategies aim to recruit alveoli for gas exchange. Although the alveolar recruitment maneuver (ARM) has been the subject of much investigation over the last two decades, its use has currently become much more prevalent for treatment of patients with ALI. Elevated lung volumes and increased pleural pressures associated with ARM may undesirably affect pulmonary vascular resistance and cardiac performance. However, the benefits of ARM in oxygenation gain, weighed against negative hemodynamic effects, remain uncertain in part due to lack of data on the effects of ARM on cardiovascular function. The primary objective of this study was to verify, in an acute model of lung injury, the effects of one type of recruitment maneuver -sustained inflation- associated with different PEEP levels on cardiac function during a determined period of observation. DESIGN: Prospective, randomized, controlled experimental study. SETTING: Academic research laboratory. SUBJECTS: Thirty-two white landrace pigs.Interventions: Thirty-two anesthetized pigs were ventilated in volume-controlled mode. The animals were randomly allocated into four groups (G1-PEEP, G2-PEEP-ARM, G3-ALI-PEEP, G4-ALI-PEEP-ARM) of eight each. PEEP values were progressively increased and decreased from 5, 10, 15 and 20 cm H2O in all animals and were kept unaltered for 20 minutes at each plateau value. Three sustained recruitment maneuvers of 30 cmH2O with 20 seconds of duration each were apllied at each PEEP level in the G2-PEEP-ARM and G4-PEEP-ALI-ARM groups. To induce an acute injury, mainly in dependent lung regions, hydrochloric acid (0.05N, 4ml/kg ) was instillated juxt carinae by means of a flexible bronchoscope in groups G3-ALI-PEEP and G4-ALI-PEEP-ARM. Transesophageal echocardiography, mixed central venous saturation (SVO2), intermittent and continous cardiac output by thermodilution, systemic and pulmonary pressures, gastric tonometry, oxygen transportation, consumption and metabolic indexes were measured at established points. MEASUREMENTS AND MAIN RESULTS: Sustained alveolar recruitment maneuver did not provoke significant additional cardiovascular negative effects in selected groups during the 3 hours of the protocol. Independently of pulmonary lesion, during progressive PEEP augmentation, it was observed a significative (p<0.001) reduction (11.8 +- 7.4%) in cardiac index during 10 cmH2O of PEEP, (25.5?5.7%) and (36.1 +- 5.1%), during 15 and 20 cmH2O respectively, accompanied by a significant reduction in SVO2 (p<0.001) during 15 and 20 cmH2O of PEEP. At the same time, end diastolic volumes of right and left ventricles were significantly reduced during 10, 15 and 20 cmH2O of PEEP (p<0.001) and 20 cmH2O of PEEP (p<0.001) respectively. Ejection fraction of RV showed significant reduction during 10 cmH2O (p<0.05), 15 and 20 cmH2O (p< 0.001) of PEEP while LV ejection fraction remained unaltered. Oxygen transportation was significantly decreased (p<0.05) during 15 and 20 cmH2O of PEEP, acompanied by a significative oxygen extraction elevation, (p<0.001) without compromise of oxygen consumption, serum lactate, gastric tonometry and delta pCO2. CONCLUSIONS: Lung instillation of hydrochloric acid in two selected groups promoted an acute injury characterized by a drop in PaO2/FIO2 ratio, a decrease in respiratory compliance and pulmonary hypertension. During 3 hours of experimental protocol, ARM did not cause a significative hemodynamic embarrassment independently of presence of LPA. The negative cardiovascular effects during this study were related to a PEEP progression in the airway. No significant difference concerning cardiovascular effects related to PEEP was observed among the four established groups.
|