• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 558
  • 134
  • 2
  • 2
  • 1
  • Tagged with
  • 695
  • 676
  • 673
  • 83
  • 41
  • 35
  • 31
  • 31
  • 30
  • 27
  • 26
  • 24
  • 20
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
601

Uppföljning av nyckeltal för större bro- och betongtunnelentreprenader :   Nyckeltal tänkta att användas för att kvalitetssäkra anbudsarbete

Due-Boje, Anna January 2009 (has links)
Uppdragsgivare för detta examensarbete är Skanska Sverige AB Region Stora Projekt, som arbetar med stora bro- och anläggningsprojekt. Störst behov ligger i att få ökad kunskap om de Allmännai projekten. Arbetet med anbudskalkyler innebär att förutse projektkostnader och kostnaderna Allmänna kostnader utgör en betydande del av projektets totalkostnad och är svårkalkylerade. Generellt uttryckt utgör denna post de byggkostnader som används gemensamt i projektet. Nyckeltal komprimerar information i syfte att göra den mer lättillgänglig för användaren. Syftet med denna rapport är att få fram nyckeltal tänkta att i första hand användas till att kvalitetssäkra kommande anbudsarbeten. Det material och data som rapporten baseras på är intern information om referensprojekten och slutrapporter. För två av resurserna kan nyckeltal presenteras, samma gäller för en tredje baserat på att referensprojekten har liknande utförande. Det är rimligt för en fjärde. De resterande är för objektsspecifika och det finns för lite underliggande data för att kunna dra någon slutsats. För dessa krävs det fler referensprojekt för att kunna få fram tillförlitlig data. / The taskmaster for this thesis is Skanska Sverige AB Region Stora Projekt, who works with large bridge- and construction projects. Greatest need is to enhance the understanding of the General costs of the projects. Tender calculation means to predict project costs and General costs are a significant part of the project's total cost and is difficult to calculate. This post is, broadly expressed, the construction costs that are used jointly in the project. Ratios compress information in order to make it more accessible to the user. The purpose of this report is to present ratios primarily intended to be used to quality-assure future tender work. The material and data to which the report is based on is internal information about the reference projects and their final reports. For two of the resources ratios can be presented, the same applies to a third based on that the reference projects have similar design. It is reasonable for a fourth. The remainder is too object-specific and there is little underlying data to draw any conclusions. For these require more reference projects in order to obtain reliable data.
602

Livscykelanalys och optimering av isoleringstjocklek för moderna byggnader : - med fokus på kv Limnologen i Växjö

Johansson, Martin, Kanellos, Konstantin January 2007 (has links)
Syftet med denna rapport är att visa hur en ökning av isolertjockleken i ett hus påverkar kostnader och energiåtgång för isoleringen i ett livscykelperspektiv, samt för husets bruksskede. I studien har en optimering av isoleringen på ett pågående byggprojekt i Växjö, kv Limnologen, utförts. Total energiåtgång för isoleringens livscykel har tagits fram från tidigare utförda livscykelanalyser (LCA). Husets värmebehov har beräknats mha information från ritningar och kontakter med personer i anknytning till kv Limnologen. En ekvation har utformats för att finna ett teoretiskt optimum för isolertjockleken med inriktning mot total energiåtgång, koldioxidutsläpp och ekonomi. Resultatet för optimeringen av total energiåtgång visar att optimum ligger vid den dubbla tjockleken för tak och grund, samt tredubbla för väggarna. För koldioxidutsläpp och ekonomin är resultatet mer beroende av husets uppvärmningskälla. Fjärrvärme med biobränslen är mer miljövänligt och ekonomiskt idag i jämförelse med fossila bränslen. Det innebär att hus som är oljeuppvärmda bör isoleras betydligt mer. I denna studie sammanställs en del faktorer såsom energi, koldioxid och ekonomi vilket gör det lättare att analysera och värdera dem. Att isolera till vårt framräknade optimum vore inte relevant då detta är ett teoretiskt värde och inte tar hänsyn till förändringar i konstruktionen och andra problem som kan uppstå. Optimeringskurvan visar att vinsten ökar snabbast de första centimetrarna av tilläggsisolering och om konstruktionen inte påverkas nämnvärt skulle det vara möjligt att utföra detta tillägg. Slutsatsen är att husen som byggs på kv Limnologen är välisolerade enligt dagens förutsättningar. / The aim with this report is to show how an increase of the thickness of insulating in a house influences the costs and the energy consumption for the insulation in a life cycle perspective and for the usage stage of the house. An optimization of the insulation on an ongoing construction project in Växjö, Limnologen has been carried out in the study. Total energy consumption for the insulation’s life cycle has been taken from earlier accomplished life cycle assessments (LCA). The house's heat need has been calculated on the basis of information from blueprints and contacts with persons in connection to Limnologen. An equation has been formulated in order to find a theoretical optimum for the insulating thickness regarding total energy consumption, carbondioxide and economy. The result of the optimization for total energy consumption shows that optimum lies at the the double thickness for ceilings and foundation, and triple for the walls. For carbondioxide and the economy the result is more depending on the house's heating source. District heating with biomass fuel is more environmentally friendly and economic today compared with fossil fuel. It means that houses that are oil heated should be insulated considerably more. In this study a compilation of some factors have been made, such as energy, carbondioxide and economy which makes it easier to compare them. Insulating to the calculated optimum is not relevant because the optimum is a theoretical value and does not take into consideration structure solutions and other problems that can arise. On the other hand the optimization curve shows that the profit increases rapidly at the first centimetres of additional insulation and if the structure is not affected markedly this addition would be profitable to carry out. The conclusion is that the buildings raised at Limnologen are well insulated with the presumptions of today.
603

Förstärkta strävor i trätakstolar för ökad tryckkapacitet : En laborativ undersökning / Reinforced compression members in wooden roof trusses : An experimental investigation

Karlsson, Tomas, Fromell, Johan January 2007 (has links)
I vissa takstolskonstruktioner kan det ibland uppstå stora tryckkrafter i diagonala reglar. I Sverige löser man oftast detta med hjälp av stagning tvärs diagonalen för att hindra utböjning i veka riktningen. Ibland när det är svårt att på plats trä in strävor på grund av utrymmesbrist och dylikt kan man spika eller skruva på en regel för att på så sätt förstärka den diagonala strävan. Detta examensarbete har undersökt två olika förstärkningsalternativ, rektangulärt- och T-tvärsnitt, med hjälp av reglar med dimension 45x95 mm2 vilka skruvas respektive spikas ihop. Detta har gjorts laborativt genom att trycka provkroppar i en provningsram och undersöka hur mycket den axiala kapaciteten ökar med förstärkning. De två olika förstärkningslösningarna bygger på att man på plats kan förstärka strävor med enkla medel. Testbitarna har levererats till Växjö universitet och är av oklassat virke. Provbitarnas E-modul har undersökts för att på teoretisk väg undersöka hur stor axialkraftskapacitet den primära strävan har utan förstärkning. Provkroppar tillverkades och konditionerades i klimatrum, med temperaturen 20°C och 65 % RF, i ca tre veckor före provtryckning. De laborativa värdena visar att den axiella kapaciteten ökar med 1,9 – 2,7 ggr för de rektangulära tvärsnitten och 2,5 – 4,0 ggr för T-tvärsnitten. Förstärkningsfaktorn är beroende av längd, förstärkningsalternativ och sammanfogning. Förstärkningseffektiviteten är högst för de längre strävorna. / In wooden roof trusses there sometimes may occur buckling in compressed web members. In most cases in Sweden this is solved by bracing between two webs to prevent buckling of the minor axis. Sometimes it is hard to brace between webs because of lack of space. Then it is possible to nail or screw a side member on the compressed web to increase the capacity. This diploma work has examined two different ways of bracing, rectangular cross section and T-bracing, with webs 45x95 mm2. Experimental tests have been made on compression webs and examine the bracing efficiency. It is important that the bracing alternatives are easy to use with simple tools. Ungraded lumber were delivered to Växjö University. The Youngs modulus of the test pieces has been examined so the critical buckling load of the main member without bracing could be calculated theoretically. The lumber was conditioned to equilibrium moisture content of approximately 12 percent in a room maintained at 65 percent relative humidity and 20°C in three weeks before testing the critical buckling load. The experimental results show that the critical buckling load increases with a factor of 1,9 – 2,7 for the rectangular cross sections and with a factor of 2,5 – 4,0 for the T-bracing. The bracing efficiency is dependent on length, bracing alternative and type of connectors.. The bracing efficiency increases for longer webs.
604

Utvärdering av styvhetsegenskaper hos ett nyutvecklat träbjälklag av limmade sidobräder / Evaluation of stiffness properties of a novel wooden floor system of glued side boards

Wadefur, Tommy, Karlsson, Viktor January 2007 (has links)
Idag blir det allt vanligare med träbyggnader högre än två våningar. Detta tillsammans med en modern arkitektur som ger stora öppna planlösningar ställer höga krav på bjälklagen i träbyggnader. Problematiken med långa spännvidder för bjälklag i trä är att klara kraven för svikt och nedböjning. Dessa krav måste uppfyllas för att säkerställa funktioner hos andra byggdelar och för att människor inte ska uppleva att golvet sviktar eller vibrerar på ett obehagligt sätt. Ett träbjälklag bestående av limmade balkar av sidobräder har utvecklats. Bjälklaget är utformat av balkar med I-tvärsnitt i primärriktningen och rektangulära balktvärsnitt i sekundärriktningen. Examensarbetet omfattar laborativa provningar och beräkningar dels för att bestämma en böjelasticitetsmodul för varje enskild limmad balk och dels för att bestämma styvhetsegenskaperna för bjälklaget. De limmade träbalkarna ingår i ett forskningsprojekt vid Växjö universitet finansierat av KK-stiftelsen, som syftar till att undersöka möjligheterna att tillverka en konkurrenskraftig produkt genom att i grönt tillstånd (otorkat) limma ihop bräder från stockens yttre delar till balkar. Balkarna levererades limmade och hyvlade till universitet där en böjelasticitetsmodul först bestämdes för varje enskild balk. Därefter monterades balkarna ihop till ett fullskaligt bjälklag som provades med olika försöksuppställningar/lastfall varvid deformationen mättes upp. Dessa deformationer blir underlag för att bestämma bjälklagets styvhet. Böjstyvheten i primärriktningen uppgår till 17,55 x 1012 Nmm2/m enligt beräkningar baserade på laborativa resultat. Böjstyvheten i sekundärriktningen uppgår till 4,5 % av primärriktningens böjstyvhet, dvs. 0,79 x 1012 Nmm2/m. Sammanfattningsvis kan man säga att böjstyvheten är hög i båda riktningar i jämförelse med vanliga träbjälklag. / In Sweden it becomes more and more common with wood buildings higher than two floors. This along with a modern architecture that gives big open plan solutions sets high requirements on the floor systems in wood buildings. The complexes of problems with long spans for floor systems in wood are to match the requirements for elasticity and deformation. These requirements must be met in order to ensure functions of other construction components, and not be unpleasant for people to walk on with respect to vibrations. A wooden floor system consisting of green glued side wood sections has been developed. The floor system is made with I-profiled beams in the primary direction and rectangular cross-sections in the secondary direction. This diploma work is based on that through elaborative testing and numeric calculations to decide the stiffness properties for each individual green glued side wood section and for the floor system. The glued side wood sections are included in a project at Växjö University, which is financed by the KK-foundation. The sections were delivered glued and planed to the university where the stiffness properties were first determinded for each individual section. Then, the sections were assembled to one fully sized floor system that was exposed to different experiments as the deformation was measured. These deformations were later used in order to decide the stiffness of the floor system. The stiffness in the primary direction was prescribed to 17,55 x 1012 Nmm2/m after calculations using results from the tests. The stiffness in the secondary direction amounts to 4,5% of the primary directions stiffness, i e. 0,79 x 1012 Nmm2/m. To sum up, one can say that the stiffness is high in both directions compared to regular wooden floor systems.
605

Passivhusen på Oxtorget

Brandt, Fredrik, Jonsson, Mathilda January 2008 (has links)
Syftet med vårt examensarbete är att undersöka hur passivhus eller så kallade nollenergihus skiljer sig i funktion samt uppbyggnad från konventionella hus. I vår undersökning tar vi upp hur utformning, orientering, material samt ett väl fungerande klimatskal påverkar energiförbrukningen. Vi har tittat närmare på faktorer som sparar energi samt hur ett typiskt passivhus är uppbyggt. För att se hur teorin fungerar i praktiken har vi tittat närmare på befintliga passivhus, nämligen de på Oxtorget i Värnamo. Vi har kommit fram till att passivhus fungerar och vi anser det som väldigt viktigt att man fortsätter driva fram arbetet och informera om dess betydelse för miljön. Passivhus blir mer och mer uppmärksammat. De är något dyrare att bygga, men man tjänar in det i längden. Lönsamheten är dock inte det viktigaste utan känslan av att man gör något bra för miljön. / The main purpose with our diploma work is to examine how passive houses or so called zero energy houses differ in function and construction compared to conventional houses. In our research we present different things such design, orientation, materials and how a fully functional climate shell affects the energy consumption. We’ve looked closer at some factors that save energy and how a typical passive house is constructed. To see how theory works in practice we have looked at existing passive houses, and that is the passive houses on Oxtorget in Värnamo. We have come to the conclusion that the passive houses works and we believe that it is very important that we continues to carry on the work and inform people about its importance to the environment. Passive houses are becoming more and more noticed. They are somewhat more expensive to build but in time you will earn the money spent back. The profit is not the most important but the feeling that you do something good for the environment.
606

Energideklaration av Svenska kyrkans byggnader i Växjö : utredning, deklaration och fördjupning nattkyla

Ericsson, Stefan, Evertsson, Torbjörn January 2008 (has links)
Detta examensarbete syftar till att utreda vilka av Svenska kyrkans byggnader i Växjö som ska energideklareras samt utföra en energideklaration av en kontorsbyggnad. I energideklarationen ingår det även att ge åtgärdsförslag för olika energibesparingsmöjligheter. En fördjupad studie i nattkylning av stommen har också utförts. Examensarbetet är uppdelat i tre huvuddelar, indelning av byggnader, utförande av energideklaration samt fördjupad studie av nattkyla. I den första delen delas byggnaderna in i grupper utifrån verksamhet och byggnadstyp och därefter utreds om de ska energideklareras. Målet med denna indelning av byggnader är att Svenska kyrkan ska få vetskap om vilka av deras byggnader som berörs av lagen om energideklarationer. I andra delen görs en energideklaration för en kontorsbyggnad. Det visar sig att det finns en hel del energibesparande åtgärder som kan göras i kontorsbyggnaden. En del av åtgärderna är endast enkla åtgärder som inte kräver något större ingrepp i byggnaden för att utföras. I den tredje delen genomförs en fördjupad studie i nattkylning av stommen i byggnader, där tung och lätt stomme jämförs gentemot varandra. För att utföra jämförelsen används simuleringsprogrammet IDA Klimat och Energi. Resultatet av simuleringen visar ingen besparing av energi till följd av nattkylning av stommen i den simulerade byggnaden, vilket leder fram till en parameterdiskussion om hur olika parametrar påverkar lönsamheten vid nattkyla. / This diploma work aims to investigate which of the Swedish church’s buildings in Växjö that needs to be energy declared and also to perform an energy declaration of an office building. In the energy declaration there’s also included measures for various energy-saving potential. An in-depth study of night-cooling of the framework has also been performed. This diploma work is divided into three main parts, classification of buildings, carrying out the energy declaration and a depth study of night-cooling of the building’s framework. In the first part buildings where divided into different groups on the basis of activities and type of building and then investigated whether to be energy declaration or not. The objective of this classification of buildings is that the Swedish church will know which of their buildings that’s affected by the law concerning energy declarations. The second part is an energy declaration of an office building. It turns out that there are a lot of energy-saving measures that can be done in the office building. Some of them are only simple measures that don’t require any major interference in the building to be performed. In the third part is carried out an in-depth study of night-cooling of buildings’ frameworks, where heavy and light frames are compared against each other. In order to carry out the comparison the simulation program IDA Climate and Energy was used. The results of the simulation shows no saving of energy as a result of night-cooling of the building frame in the simulated building, which leads to a parameter discussion on how various parameters affecting the profitability of night-cooling.
607

Hur följs kraven på tillgänglighet vid nybyggande av bostäder? : - En studie av utvalda bostadsprojekt i tre närliggande kommuner

Axelsson, Therese January 2008 (has links)
The purpose of this study is to find out how housebuilding meets the demands of availability for people with some sort of disability. The rules and demands of availability are stated in Boverkets byggregler, BBR and the Swedish standard, SS 91 42 21:2006 (publ.5). The projects in this study are compared to the rules and demands of BBR and SS 91 42 21:2006 (publ.5). The rapport studies three different house projects in three different municipalities and the result shows that only three of these nine projects meet the demands of availability for disabled people.
608

Utvärdering av styvhetsegenskaper hos ett nyutvecklat träbjälklag / Evaluation of stiffness properties of a novel wooden floor system

Dover, Pär, Berggren, Peter, Fahlgren, John January 2006 (has links)
I samband med att intresset för att bygga högre trähus har ökat så krävs nya lösningar för att t.ex. kunna möta efterfrågan på stora öppna ytor och långa spännvidder. Träbjälklag med lång spännvidd har dock oftast svårigheter med att klara kraven på svikt och vibrationer. Ett nyutvecklat förslag på träbjälklag som förmodas klara dessa krav bättre än traditionella träbjälklag har varit utgångspunkten för detta examensarbete där syftet har varit att undersöka bjälklagets styvhet. Detta gjordes laborativt genom att bygga och testa en prototyp av det föreslagna bjälklaget och genom att en numerisk modell baserad på finita element metoden togs fram och användes för att studera hur olika parametrar påverkar bjälklagets styvhetsegenskaper. Bjälklagets design bygger på fackverksprincipen i primärriktningen och på balkverkan i sekundärriktningen. De ingående komponenterna har kommit prefabricerade till Växjö universitet där de har monterats ihop till ett fullskaligt bjälklagselement. Elementet har sedan utsatts för ett antal belastningsfall där nedböjningarna uppmätts vilka sedan givit underlag för att få värden på bjälklagets effektiva styvhetsegenskaper. Både de laborativa och de simulerade resultaten visar på en hög böjstyvhet i primärriktningen d.v.s. 18,9•106 Nm2/m [EI/b] respektive 18,6•106 Nm2/m [EI/b]. Även böjstyvheten i sekundärriktningen är hög d.v.s. motsvarar 21,2 % respektive 17,1 % av styvheten i primärriktningen. I beräkningsmodellen har det dessutom undersökts hur ett övre lager av spånskivor inverkar på bjälklagets styvhet. / The interest for building higher and larger wooden houses has increased in Sweden during the last decade resulting in higher requirements on the technical performance of such structures in order to met demands on large open surfaces and large spans of floors. Wooden floor systems with large spans often have difficulties, however, to meet the vibration requirements. A novel floor system, likely to handle the vibration requirements better than traditional wooden floor systems, is the basis for this master thesis. The purpose is to examine the stiffness of the floor by building and testing a prototype and by producing a numerical model based on the finite element method. In the longitudinal, main load-bearing direction the floor system works as a truss with flanges of longitudinal oriented timber members and web diagonals of transversely oriented members. In the transverse direction the web diagonals work as beams. The components were prefabricated elsewhere and assembled at Växjö University into a prototype. The prototype was then exposed to a number of different load cases. Deflections were measured and stiffness properties of the floor were derived. In addition to the experimental analysis the numerical model was used to calculate deflections when subjected to different load cases and for evaluating the principal stiffness properties of the floor. Both the experimental and the calculated results using the numerical model show high bending stiffness in the longitudinal direction, EI/b = 18,9•106 Nm2/m and 18,6•106 Nm2/m respectively. Also the bending stiffness in the transversal direction is high and equivalent to 21,2 % or 17,1 % (testing and simulation respectively) of the bending stiffness in the longitudinal direction. Using numerical analysis, also the effect on the stiffness of adding an upper layer of a 22 mm particleboard was examined.
609

Digital hantering av kontrollåtgärder för kommunala fasigheter / Computerized administration for municipal real property units

Larsson, Sofia January 2009 (has links)
No description available.
610

Projektering av platsbyggd villa / Planning of placebuild detached house

Al Jaafar, Jaafar January 2008 (has links)
Abstract (in English) "This thesis work is a design project of an on-site construcktions. The issue addressed by the project was how to devise and design an detached house I have examined which architecture-drawings, construcktion-drawings and static calculations are needed to produce an on-site construcktions detached house. The result is presented in the finished drawings for the construction documents, which show a one-storey detached house with an attractive/accessible construction plan. It uses the combination of a strong style of architecture and a clear influence of functional design. This is clarified by the bench ceilings, and the facade, which is partly laying panel, partly white trimmed. Size: 153 square meters Number of rooms: 6, where of 3 are bedrooms." / Sammanfattning Detta examensarbete är ett utformningsprojekt av en platsbyggd villa. Frågeställningen till projektet var hur man kan utforma en villa. Jag har undersökt vilka A-ritningar, K-ritningar samt statiska beräkningar som behövs för att producera en platsbyggd villa. Resultatet visar färdiga ritningar till bygghandlingar vilket betyder enplans villa med attraktiv/öppen planlösning och en stark byggnadsstil med tydliga inflytanden av funkisstil. Detta tydliggörs genom pulpettaken, och fasaden som är delvis liggande panel, delvis vit putsad. Yta: 153 kvm Antal rum: 6, varav sovrum: 3

Page generated in 0.2826 seconds