261 |
CAD/CAM Resin-Based Composites for Use in Long-Term Temporary Fixed Dental ProsthesesHensel, Franziska, Koenig, Andreas, Doerfler, Hans-Martin, Fuchs, Florian, Rosentritt, Martin, Hahnel, Sebastian 08 May 2023 (has links)
The aim of this in vitro study was to analyse the performance of CAD/CAM resin-based composites for the fabrication of long-term temporary fixed dental prostheses (FDP) and to compare it to other commercially available alternative materials regarding its long-term stability. Four CAD/CAM materials [Structur CAD (SC), VITA CAD-Temp (CT), Grandio disc (GD), and Lava Esthetic (LE)] and two direct RBCs [(Structur 3 (S3) and LuxaCrown (LC)] were used to fabricate three-unit FDPs. 10/20 FDPs were subjected to thermal cycling and mechanical loading by chewing simulation and 10/20 FDPs were stored in distilled water. Two FDPs of each material were forwarded to additional image diagnostics prior and after chewing simulation. Fracture loads were measured and data were statistically analysed. SC is suitable for use as a long-term temporary (two years) three-unit FDP. In comparison to CT, SC featured significantly higher breaking forces (SC > 800 N; CT < 600 N) and the surface wear of the antagonists was (significantly) lower and the abrasion of the FDP was similar. The high breaking forces (1100–1327 N) of GD and the small difference compared to LE regarding flexural strength showed that the material might be used for the fabrication of three-unit FDPs. With the exception of S3, all analysed direct or indirect materials are suitable for the fabrication of temporary FDPs.
|
262 |
Uppdatering av skogsbruksplaner med laserdata : En studie om noggrannhet i skattningar av skogliga variabler / Updating forest management plans with laser data : A study of accuracy in estimations of forest variablesDahlström, Emma, Zetterlund, Gustaf January 2023 (has links)
Skogsbruksplanen är ett viktigt verktyg för dagens skogsägare. Uppdatering av skogsbruksplaner kräver vanligtvis omfattande fältmätningar för att samla in aktuella data om skogen. En ny metod för att uppdatera skogsbruksplaner har utvecklats av skogsägarföreningen Södra och Field Sweden AB, vilken minskar behovet av manuella fältmätningar. En studie genomfördes för att utvärdera noggrannhet och tillförlitlighet i den nya metoden. Studien indikerade högre noggrannhet i skattningar av volym, grundytevägd medeldiameter och grundytevägd medelhöjd i laserbaserad skogsbruksplan jämfört med konventionell skogsbruksplan. Grundyta var den variabeln som erhöll högst noggrannhet via konventionella skattningar. Metoden bedömdes tillförlitlig, dock bör vidare studier utföras för att säkerställa noggrannhet och tillförlitlighet i laserbaserade skattningar innan metoden implementeras på hela skogsinnehav.
|
263 |
Protease Expression Levels in Prostate Cancer Tissue Can Explain Prostate Cancer-Associated Seminal Biomarkers: An Explorative Concept StudyNeuhaus, Jochen, Schiffer, Eric, Mannello, Ferdinando, Horn, Lars-Christian, Ganzer, Roman, Stolzenburg, Jens-Uwe 16 January 2024 (has links)
Previously, we described prostate cancer (PCa) detection (83% sensitivity; 67% specificity) in
seminal plasma by CE-MS/MS. Moreover, advanced disease was distinguished from organ-confined
tumors with 80% sensitivity and 82% specificity. The discovered biomarkers were naturally occurring
fragments of larger seminal proteins, predominantly semenogelin 1 and 2, representing endpoints of
the ejaculate liquefaction. Here we identified proteases putatively involved in PCa specific protein
cleavage, and examined gene expression and tissue protein levels, jointly with cell localization in
normal prostate (nP), benign prostate hyperplasia (BPH), seminal vesicles and PCa using qPCR,
Western blotting and confocal laser scanning microscopy. We found differential gene expression of
chymase (CMA1), matrix metalloproteinases (MMP3, MMP7), and upregulation of MMP14 and tissue
inhibitors (TIMP1 and TIMP2) in BPH. In contrast tissue protein levels of MMP14 were downregulated
in PCa. MMP3/TIMP1 and MMP7/TIMP1 ratios were decreased in BPH. In seminal vesicles, we
found low-level expression of most proteases and, interestingly, we also detected TIMP1 and low
levels of TIMP2. We conclude that MMP3 and MMP7 activity is different in PCa compared to BPH
due to fine regulation by their inhibitor TIMP1. Our findings support the concept of seminal plasma
biomarkers as non-invasive tool for PCa detection and risk stratification.
|
264 |
Digitalisering inom förvaltning : Dagens möjligheter med BIM för att effektivisera informationshantering inom förvaltning / Digitization in facility management : Today's opportunities with BIM to improve information managementNoori, Zaed, Rydell, William January 2022 (has links)
Digitalisering av byggnadsinformation är ett viktigt verktyg för att uppnå effektivareinformationshantering inom förvaltning. Bristande kommunikation inom bygg- ochförvaltningsprocessen kan kosta upp till 60 miljarder kronor årligen. BIM är en förkortning förbyggnadsinformationsmodell och implementering av tekniken inom förvaltning innebärminskade informationsförluster, vilket ger besparing i tid och resurser. Tekniken används mestinom projekterings- och produktionsskedet, därefter minskas användningen av BIM-modellerinom förvaltningsskedet.Syftet med rapporten är att ta reda på hur fastighetsbolag i dagsläget använder sig av BIM ochdigitalisering inom förvaltning samt undersöka vilka områden som kan utvecklas. Rapportenär avgränsad till fem digitaliseringstekniker: Digital Tvilling, Laserskanning (Scan-to-BIM),Common Data Environment (CDE), Augmented Reality (AR) och Internet of Things (IoT).Rapporten är baserad på litteraturstudier samt kvalitativa intervjuer utförda med sex aktörerfrån olika företag. Genom intervjustudien undersöks hur dessa tekniker i kombination medBIM kan förbättra informationshanteringen inom förvaltningsskedet.Resultatet visar att användningen av BIM inom förvaltningen är låg i dagsläget. Detta då detfinns en ovilja samt brist på kunskap angående ämnet. Resultatet visar även att det finns storpotential till förbättring med implementering av BIM och digitalisering inom förvaltningen.Med BIM och digitalisering får informationen potential till högre kvalité samt bättre struktur,dessutom tillgängliggörs flera möjligheter av automatisering inom förvaltningen.Behovet av uppdaterad samt strukturerad byggnadsinformation inom förvaltningen ökarständigt. BIM är grunden för digitaliseringen inom förvaltning. Desto bättre kännedomförvaltare har om sina utrymmen och byggnadsinformation, desto mer digitala teknikerkommer kunna tillämpas inom förvaltningen. På detta vis möjliggörs potentialen tillutveckling inom förvaltning. / Digitization of building information is an important tool for achieving more efficientinformation management within facility management. Lack of communication in theconstruction- and facility management process can cost up to 60 billion (SEK) annually. BIMis an abbreviation for Building Information Modeling and implementation of the technology inthe facility management means reduced information losses, which provides savings in timeand resources. The technology is mostly used in the design- and construction phase, afterwhich the use of BIM models in the facility management phase decreases.The purpose of the report is to find out how facility management organizations currently useBIM and digitization in facility management, and also examine potential areas ofimprovement. The report is limited to five digitization techniques: Digital Twin, Laserscanning (Scan-to-BIM), Common Data Environment (CDE), Augmented Reality (AR) andInternet of Things (IoT). The report is based on literature studies and qualitative interviewsconducted with six respondents from different companies. The interview study examines howthese techniques in combination with BIM can improve information management within thefacility management phase.The result show that the usage of BIM in facility management is low as of today. This is due toreluctance and a lack of knowledge about the subject. The result also reveals that there is a lotof room for improvement in facility management with the implementation of BIM anddigitalization. With BIM and digitization, information has the potential for increased qualityand better structure, as well as various possibilities for automation options within the facilitymanagement.The need for advanced and well-structured building information within facility management isconstantly increasing. BIM is the foundation for digitization in facility management. Thebetter the managers' knowledge of their areas and building information, the more digitaltechnologies can be used in facility management. In this way, the possibility for facilitymanagement development is thus made possible.
|
265 |
Optimizing Remote Sensing Methodology for Burial Mounds in the United States and United KingdomCorkum II, Alexander C. January 2019 (has links)
Within the archaeological record ‘mounds’ are often ubiquitous. They are
common in many ancient cultures, and they vary in size, construction
techniques and use. This research is focused upon optimizing the use of remote
sensing for the non-invasive study of mounds both in the United States and the
United Kingdom.
This thesis presents three representative earthen mound sites and proposes a
comprehensive and modular survey methodology to guide the planning and
execution of a mound survey tailored to the unique requirements presented by
the cultural resource at a particular location. In doing so, the research has
provided optimized approaches to high resolution three-dimensional
topographic models using a variety of digital methods. These models have been
shown to accurately capture the variability of the modern ground surface, which
is of vital importance to the management of the mounds. Furthermore, these
models have proved vital for integrating geophysical methods into the holistic
workspace, thereby providing a better archaeological understanding of the
below ground remains.
Every mound surveyed presented different challenges, and therefore had to be
approached in a slightly different way. However, the general methodology was
highly effective for both characterizing below-ground archaeological and natural
anomalies, and for assessing the state of preservation of all mounds surveyed.
As a result, a flowchart has been generated for non-invasive assessment of mounds in general. If followed, this will allow the production of a “snapshot” of
the mound or mound group at a fixed point in time with the resolution necessary
to produce useful and insightful interpretation.
While this research focuses on the application of geophysical and topographic
survey in the United Kingdom and United States to a mound or mound group,
this methodology and the associated outcomes can be valuable more globally
not only for archaeology, but also heritage management.
|
266 |
Jämförelseanalys av höjdmodeller skapade med LiDAR-data från UAV och flygplan för projektering av kraftledningsgator / A comparative analysis of Digital Elevation Models created with LiDAR data from UAV and airplaneEdlund, Hanna January 2023 (has links)
I dagsläget står det svenska kraftnätet inför en stor utmaning om det ska kunna klara av att tillgodose Sveriges växande elbehov. Stora delar av kraftnätet måste förnyas samtidigt som det byggs ut. Vid projektering av nya kraftledningsgator måste geografisk information samlas in för att kunna planera arbetet och representera de möjliga kraftledningsgatorna som höjdmodeller. Det är då viktigt att denna data är korrekt. LiDAR-data är ett bra alternativ då det kan ge en bra bild av marken trots vegetation som kan befinna sig i en eventuell kraftledningsgata. I dagsläget används antingen Lantmäteriets Nationella Höjdmodellen (NH-modellen), eller så genomförs en luftburen laserskanning med hjälp av flygplan. Då NH-modellen ibland kan upplevas som otillräcklig på grund av sin låga upplösning, samtidigt som luftburen laserskanning kan vara kostsamt både ekonomiskt och ur en miljösynpunkt är det intressant att utforska alternativa metoder. Syftet med detta examensarbete är att genomföra en jämförelseanalys av höjdmodeller genererade med LiDAR-data insamlade med UAV och flygplan för att få svar på vad som väsentligt skiljer dem åt och ifall LiDAR-data insamlat med UAV kan vara ett alternativ till LiDAR-data insamlat med flygplan. Detta görs tillsammans med företagen Nektab och Swescan för att undersöka möjligheterna att kunna erbjuda en ny produkt till sina kunder och uppdragsgivare. Ett tidigare projekterat område utanför Horndal i Dalarna, undersöktes då det fanns tillgängliga LiDAR-data från en tidigare luftburen laserskanning gjord med flygplan. LiDAR-data samlades in med drönare med två olika skanningsmetoder, repetitive och non-repetitive, den 3:e maj 2023. Bearbetning av punktmolnet genomfördes i DJI Terra och Terrasolids programvaror Terrascan och Terramatch. Kvalitetsberäkningar genomfördes i Excel. Höjdmodeller skapades i Esris Arcmap 10.8 och analyser gjordes för att jämföra de olika höjdmodellernas höjdvärden, lutning samt profiler. Punktmolnen genererade med UAV-LiDAR hade en lägesnoggrannhet i höjd som uppfyllde kraven för HMK-standardnivå 3, och punktmolnet genererat med skanningsmetoden non-repetitive hade en bättre lägesnoggrannhet i höjd än punktmolnet genererat med flygplans-LiDAR. Skillnaderna som kunde upptäckas mellan de olika höjdmodellerna var små och påverkades både av skillnader i klassning och insamlingsmetod. Slutsatsen som drogs är att insamling av LiDAR-data med UAV och generering av kvalitativa höjdmodeller med dessa data är fullt möjligt för mindre områden så som det i det här arbetet. / The Swedish power grid is currently facing a big challenge if it’s going to be able to meet Sweden’s growing demand for electricity. While large parts of the power grid must be updated, there also needs to be a big expansion. When planning new corridors for the powerlines, geographical information must be collected to be able to visualize said corridors as Digital Elevation Models (DEMs) and it is thus important that the data is correct. LiDAR-data is a suitable alternative for this as it can represent the ground well despite any vegetation that might be present in the planned corridor. Currently open-source data from the Swedish National Land Survey, the National Elevation Model (the NH-model), is often used, or the area is mapped with airborne laser-scanning from a plane. However, the NH-model is sometimes not a suitable alternative due to its low resolution, while airborne laser-scanning can be both environmentally and economically costly. It is therefore interesting to explore alternative methods. The aim of this bachelor thesis is to conduct a comparative analysis between DEMs generated by LiDAR-data collected by UAV and by plane to see where they differ, and if LiDAR-data collected by UAV is a potential alternative to LiDAR-data collected by plane. This will be done in collaboration with Nektab and Swescan to explore the possibility of being able to offer a new product to their customers and clients. A previously planned area outside the Swedish town of Horndal in the county of Dalarna, was used due to already existing plane-collected LiDAR-data. LiDAR-data was collected with an UAV through two different scanner-methods, repetitive and non-repetitive, on the 3rd of May 2023. The processing of the pointclouds were performed in DJI Terra and Terrasolids software Terrascan and Terramatch. Quality calculations and control was done in Excel. DEMs were created in Esris software Arcmap 10.8 and different analyses were performed to compare the DEMs elevation, slope, and profiles. The point clouds generated from the UAV-LiDAR had a positional accuracy equivalent to the Swedish HMK-standard level 3, and the pointcloud generated from the non-repetitive scanner-method had a better positional accuracy for the z-value than the pointcloud generated from the plane-LiDAR. The differences between the DEMs were small and were caused both by difference in classification of the point clouds and collection method. The conclusion is that collection of LiDAR-data through UAV and the generation of high quality DEMs from this data is fully possible for smaller areas such as the one in this thesis.
|
267 |
Rekonstruktion av Ör kyrkas tidigmedeltida takkonstruktion / Reconstruction of Ör church early medieval roof structureLorentsson, Jimmy, Forssgren, David January 2022 (has links)
During an inventory of Ör church’s roof structure in 2021, it was discovered that the roofstructure above the church’s nave contains a large amount of reused structural parts froman earlier roof structure. The reused structural parts are most likely originated from Örchurch’s early medieval roof structure.This thesis is an attempt to reconstruct the early medieval roof structure with the use of3D-laser scanning. The goal is to present a possible shape and 3D-model of the earlymedieval roof structure. The existing roof structure will also be documented. One aim ofthe thesis is to develop and evaluate the method of using 3D-laser scanning for thispurpose.The reconstruction resulted in eight different shapes and 3D-models of the early medievalroof structure. The documentation of the existing roof structure above the nave resulted inupdated section, plan and detailed drawings.The method of using 3D-laser scanning gave a detailed point cloud of the existing roofstructure. The point cloud had low density points in certain parts of the roof structurewhich is a consequence from the implementation of the 3D laser scanning. For thismethod a field study and planning in advance is recommended for best possible result.
|
268 |
Volume Calculation Based on LiDAR Data / Volymberäkning baserad på LiDAR dataAmaglo, Worlanyo Yao January 2021 (has links)
In this thesis project, the main objective is to compare and evaluate different surveying methodsfor volume determination; Photogrammetry, Terrestrial Laser Scanning(TLS) and Aerial LaserScanning (ALS) based on time consumption, efficiency and safety in the mining industry. In addition,a volumetric computational method based on coordinates would be formulated to estimatethe volume of stockpiles using lidar data captured with a laser scanner. The use of GNSS receiver, UAV (Unmanned Aerial Vehicle) equipped with a LiDAR sensor as wellas a camera, and terrestrial laser scanner were adopted for making measurements on stockpiles. Trimble Business Center and Trimble RealWorks were used in processing LiDAR data from TLSand ALS. Two volume computational approaches were also explored using both TLS and ALSLiDAR data. Agisoft Photoscan was used in processing the images captured adopting the structurefrom motion principle. These softwares were used to estimate the volume of the stockpile. Matlabwas used to estimate the volume of stockpile using LiDAR data. A volume computational methodbased on coordinates of point cloud was implemented. Analysis based on time taken to captureand process all data types till the fi nal product was done. The results obtained from each datacapturing methods were evaluated. Simulated data technology is also adopted in this project asit can be modeled in different ways to study the effect of surface roughness (point density) onvolume estimated. A part of this project explores the use of MATLAB to filter out unwantedpoint clouds coming from the weeds that grow on the surface of an abandoned stockpile and alsosurface areas that were to be excluded from the volume computation, as in this case. From the results obtained, TLS and ALS do not differ much in the final volume estimated. Photogrammetry on the other-hand estimated a higher volume as compared to the other surveymethods. MATLAB in estimating the volume of stockpile achieves approximately an equal estimate as that of the TLS and ALS within a short period of time. The point density and fi ltering algorithm playsa critical role in volume computation which helps in providing a good estimate of the stockpile. Findings from this project show that is it time consuming to estimate the volume of stockpileusing TLS and Photogrammetric approach. In terms of safety on an active mining site, these twosurvey method have high risk probability as compared to the ALS approach. The accuracy forthe data captured and processed can be said to be satisfactory for each survey method. / I detta avhandlingsprojekt var huvudmålet att jämföra och utvärdera tre kartläggningsmetoder för volymbestämning: Fotogrammetri, Terrestrial Laser Scanning (TLS) och Aerial Laser Scan-ning (ALS) baserat på tidsförbrukning, effektivitet och säkerhet i gruvindustrin. Dessutom formulerades en volymetrisk beräkningsmetod baserad på koordinater för att uppskatta volymen av lager med hjälp av lidardata som fångats med en laserskanner. Användningen av GNSS-mottagare, UAV (obemannad flygbil) utrustad med en LiDAR-sensor samt en kamera och markbunden laserscanner antogs för att göra mätningar på lager. Trimble Business Center och Trimble RealWorks användes vid bearbetning av LiDAR-data från TLS och ALS. Två volymberäkningsmetoder undersöktes också med både TLS- och ALS LiDAR-data. Agisoft Photoscan användes vid bearbetning av de bilder som tagits och antagit strukturen från rörelseprincipen. Denna programvara användes för att uppskatta volymen på lagret. Matlab användes för att uppskatta volymen av lager med LiDAR-data. En volymberäkningsmetod baserad på koordinater för punktmoln implementerades i Matlab. Analys baserad på den tid det tar att fånga och bearbeta alla datatyper tills den slutliga produkten var klar. Resultaten från varje datafångstmetod utvärderades. Simulerad datateknik antas också i detta projekt eftersom den kan modelleras på olika sätt för att studera effekten av ytjämnhet (punkttäthet) på den uppskattade volymen. En del av detta projekt utforskar användningen av MATLAB för att filtrera bort oönskade punktmoln som kommer från ogräset som växer på ytan av ett övergivet lager och även ytarealer som skulle uteslutas från volymberäkningen, som i detta fall. Från de erhållna resultaten skiljer sig TLS och ALS inte mycket i de slutliga volymuppskattningarna. Fotogrammetri å andra sidan uppskattade en högre volym jämfört med de andra undersöknings-metoderna. MATLAB vid uppskattning av lagervolymen uppnår ungefär lika stor uppskattning som TLS och ALS inom en kort tidsperiod. Punkttätheten och filtreringsalgoritmen spelar en viktig roll i volymberäkning som hjälper till att ge en bra uppskattning av lagret. Resultat från detta projekt visar att det är tidskrävande att uppskatta lagervolymen med TLS och fotogram-metrisk metod. När det gäller säkerhet på en aktiv gruvplats har dessa två undersökningsmetoder hög risk sannolikhet jämfört med ALS-metoden. Noggrannheten för de insamlade och bearbetade uppgifterna kan sägas vara tillfredsställande för varje undersökningsmetod.
|
269 |
Utvärdering av två digitala terrängmodeller på öppna ytor : Framställda med NRTK-GNSS och Laserdata NHCastenvall, Anna, Petersson, Elin January 2020 (has links)
En digital terrängmodell (DTM) representerar endast markytans form och har en bred användning inom t.ex. samhällsplanering. Det finns olika framställningsmetoder för att skapa en DTM, där de mest använda metoderna är mark- eller flygburen laserskanning samt terrester- eller satellitbaserad mätning. Flygburen laserskanning (FLS) använder sig av tekniken LiDAR (Light Detection And Ranging) där avstånd mäts med laser. Lantmäteriet påbörjade ett projekt 2009, vilket gick ut på att laserskanna hela Sverige med FLS och projektet blev klart 2019. Resultatet blev Laserdata NH (Nationella Höjdmodellen) med en lägesnoggrannhet i höjd på 0,1 m. Syftet med studien är att kontrollera mätosäkerheten för Laserdata NH samt undersöka om den kan ersätta terrestra mätningar, t.ex. GNSS vid skapande av DTM:er. Studieområdet är ca 0,85 ha och består av en gräsyta omgiven av grusvägar. Området är beläget i Teknikparken, Gävle. För att se ifall Laserdata NH kan ersätta GNSS-mätningar skapades en DTM från Laserdata NH samt en DTM från mätningar med NRTK-GNSS. Alla inmätningar följde de krav och toleranser vilka specificeras i SIS-TS 21144:2016. För att kunna kontrollera mätosäkerheten för Laserdata NH mättes kontrollprofiler in, vilka agerade som referens. Kontrollprofilerna användes även som referens när de båda DTM:erna jämfördes mot varandra. Max- och min avvikelse, medelavvikelse, standardosäkerhet samt RMS räknades ut på varje enskild profil, per markyta och för de två modellerna. Beräkningarna utfördes för att se ifall värdena låg för högt eller för lågt i någon del av ett område samt för att kunna se sannolikheten för systematiska avvikelser. En statistisk analys utfördes för att se ifall det finns någon skillnad mellan DTM och kontrollprofilernas medelavvikelse. Resultatet visade att det fanns en statistisk signifikant avvikelse på medelavvikelsen mellan DTM skapad av Laserdata NH och kontrollprofiler för både grus- och gräsytorna. Detta innebär att Laserdata NH inte kan ersätta NRTK-GNSS på öppna, jämna gräsytor eller plana grusytor. Kontrollerna av de två DTM:erna klarar toleranserna enligt SIS-TS 21144:2016 och anses vara tillförlitliga. Studien kom till slutsatsen att Laserdata NH kan användas utan komplettering till översiktliga planeringar. Detaljerade analyser med Laserdata NH behöver dock kompletteras med ytterligare mätningar eller ortofoto för att erhålla mer trovärdiga resultat. / A Digital Terrain Model (DTM) only represent the surface and has a broad application within, for example, community planning. There are different ways of producing a DTM, with the most common methods being ground- or airborne laser scanning and terrestrial- or satellite based measurement. Airborne laser scanning (ALS) uses the technique LiDAR (Light Detection and Ranging) which measures distances with laser. Lantmäteriet, the Swedish cadastral mapping and surveying authority, began in 2009 with a project to scan entire Sweden with ALS and was finished in 2019. The outcome of the project was a new national height model that is called Laserdata NH with a positional accuracy of 0,1 m in height. The purpose of this bachelor thesis is to study the uncertainty of Laserdata NH and to investigate if it can replace terrestrial measurements, for example replacing Laserdata NH with GNSS mapping. The study area is approximately 0,85 hectares and consists of a grassland area surrounded by gravel paths. The area is located in Teknikparken, Gävle. To see if Laserdata NH can replace GNSS-measurements a DTM was created from Laserdata NH as well as a DTM created from measurements with NRTK-GNSS. All measurements followed the requirements and tolerances according to SIS-TS 21144:2016. To control the uncertainty for Laserdata NH, control profiles were measured, which acted as a reference. The control profiles were also used as a reference when comparing the two DTMs. Max and min deviation, mean deviation, standard deviation and RMS were calculated for each profile, per ground area and using two models. The calculations were performed to see if the values were too high or too low in any part of an area and to be able to see the probability of systematic deviations. A statistical analysis was performed to see if there were any difference between the DTM and the mean deviation of the control profiles. The result showed that there was a statistic significant deviation on the mean deviation between the DTM created by Laserdata NH and the control profile for both the gravel and the grass surface. This means that Laserdata NH cannot replace NRTK-GNSS on open, plain grass or gravel surfaces. The controls of the two DTMs are within the tolerances according to SIS-TS 21144:2016 and are considered reliable. The study concluded that Laserdata NH can be used without supplement to do general plans. However, for detailed analysis Laserdata NH needs to be supplemented with additional measurements or orthophoto.
|
270 |
Utvärdering av SLAM och indirekt georefering av punktmolnsdata : En jämförselse mellan de två laserskannrarna Leica Scanstation P40 och Leica RTC 360 3D.Mattsson, Markus, Eng, Rikard January 2020 (has links)
Detta är en fallstudie där två olika Laserskannrar jämförs. Dessa skannrar skiljer sig då de använder två skilda metoder för punktmolnsregistrering. Dessa två metoder är: SLAM (Simultaneous Localization and Mapping) -baserad punktmolnsregistrering och punktmolnsregistrering med den indirekta två-stegs-metoden. Målet med projektet var således att granska den statiska SLAM-baserade skannern Leica RTC 360 3D och jämföra den med den mer traditionsenliga terrestra laserskannern Leica Scanstation P40. Denna undersökning är relevant eftersom det finns en tydlig skillnad mellan dessa laserskannrar både ur en planerings- och en effektivitetssynpunkt. Den statiska SLAM skannern RTC 360 har möjligheten att vara väldigt tidseffektiv då den använder sig av SLAM algoritmen VIS (Visual Inertial System) för punkmolnsregistrering i fält, samt att skannern använder en IMU (Inertial Measurement Unit) som möjliggör skanningar med hög kvalitet utan att instrumentet är ordentligt horisonterat. Vilket är en förutsättning för att kunna genomföra en skanning med P40. Punktmolnen från dessa två laserskannrar jämförs med varandra och granskas visuellt för att analysera vilka skillnader som finns mellan dem. Samma punktäthet används och skanningarna genomförs från samma positioner med båda instrumenten. Utöver detta görs en statistisk undersökning med hjälp av kontrollpunkter och RMS-värden beräknas med hjälp av dessa. För att tillåta denna statistiska analys, georefererades båda punktmolnen med indirekt georeferering till referenssystemet SWEREF 99 16 30 i plan samt RH 2000 i höjd. Just denna process var något enklare att genomföra med P40 än med RTC 360. Då P40 data var något bättre anpassat för bearbetning i Leica Cyclone. Vilket var de program som främst användes för bearbetning av data. RTC 360 använder två pulser för att skanna in varje punkt, vilket resulterade i att den skannade in något fler punkter. Framförallt märktes denna funktion på områden som traditionellt är svåra att skanna med en laserskanner, främst blanka, svarta områden. Det visade sig av kontrollpunkterna att det fanns en liten variation mellan punktmolnenskvalitet där lasersdata från P40 höll 1–2 millimeters kvalitet. Ur detta resultat kunde slutsatsen dras att Leica Scanstation P40 är något bättre för geodetiska ändamål med mycket höga krav på georefereringen. I det flesta andra sammanhang är RTC 360 att rekommendera. Leicas RTC 360 är ett bra exempel på hur SLAM-algoritmen kan användas för att förenkla många laserskanningsprojekt. Även i de projekten med höga krav på detaljrikedom. / This is a case study which aims to compare two different laser scanners. The main difference between these two scanners is that they use different solutions for registration of point clouds. These two solutions are SLAM (Simultaneous Localization and Mapping) as well as the indirect two-step approach. The thesis aims at comparing the static SLAM-based scanner Leica RTC 360 with the more traditional scanner Leica Scanstation P40. This is a relevant study due to the big differences between these two scanners, in the aspect of both how much preparation that is need and how effective both scanners are. The static SLAM scanner RTC 360 has the possibility to be very time efficient due to use of the SLAM-algorithm called VIS (Visual Inertial System) that are used for alignment of different point clouds as early as in the fieldwork. The RTC 360 also uses an IMU (Inertial Measurement Unit) that allows the laser scanner to do complete and detailed scans without the need to be perfectly levelled. The P40 on the other hand do need to be precisely levelled to be able to complete a scan. The point clouds from these two laser scanners are compared with each other by reviewing the visual features of the two clouds and finding differences between the point clouds. The same point density was used in both clouds and the scans took place from the same positions with both scanners. A statistical comparison was also made. This statistical analysis was made with use of control points and RMS values that were established with the help of these. This statistical analysis was made possible by the fact that both point clouds were georeferenced to the reference system SWEREF 99 16 30 as well the system RH 2000 for height. This process of georeferencing both clouds was easier to perform with the P40 than the RTC 360. Because the laser data from P40 were slightly better suited for the program Leica Cyclone, which were the program that was used for most of the data processing. RTC 360 uses two individual laser-pulses for each scanned point. This resulted in that the RTC 360 scanned some more points compared to the P40. This difference was extra noticeable on surfaces that usually are difficult for laser scanners to scan, such as plain, black surfaces. The control points showed that quality of both point clouds was very similar to each other. The P40 showed slightly higher accuracy, about 1-2millimeter, relative to the RTC 360 scanner. This resulted in the conclusion that P40 were slightly better for geodic purposes with very high demands on the georeferencing. In most of the other cases RTC 360 is the recommended scanner. Leica RTC 360 is a good example of how the SLAM-algorithm can be used to make many laser scanning projects easier and more efficient.
|
Page generated in 0.0966 seconds