• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 208
  • 6
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 217
  • 71
  • 64
  • 53
  • 50
  • 43
  • 43
  • 42
  • 35
  • 34
  • 33
  • 29
  • 25
  • 24
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Análise comparativa da expressão dos genes Dapper (Dpr) durante a ontogênese dos membros de camundongo (Mus musculus C57BL/6) e galinha (Gallus gallus) / Comparative analysis of Dapper (Dpr) gene expression during limbs ontogeny of mouse (Mus musculus C57BL/6) and chicken (Gallus gallus)

Sensiate, Lucimara Aparecida 18 August 2018 (has links)
Orientador: Lúcia Elvira Alvares / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-18T00:32:50Z (GMT). No. of bitstreams: 1 Sensiate_LucimaraAparecida_M.pdf: 8827752 bytes, checksum: 66afd653eb6cf0a2ff14cc79c158cfc1 (MD5) Previous issue date: 2011 / Resumo: Dentre as moléculas envolvidas na sinalização molecular durante o desenvolvimento, têm papel de destaque aquelas envolvidas nas vias de sinalização Wnt e TGF-ß. Trabalhos demonstram que as proteínas Dapper (Dpr) são capazes de modular tais vias de sinalização. A família de genes Dpr é constituída por três componentes: Dpr1, Dpr2 e Dpr3 em peixe-zebra, camundongo e humanos e Dpr1 e Dpr2 em aves. Os genes Dpr têm sido associados a movimentos morfogenéticos durante a gastrulação, especificação do mesoderma, morfogênese do encéfalo, coração e olhos. Apesar da grande relevância desta família gênica para o desenvolvimento, pouco se sabe sobre o padrão de expressão de tais genes em mamíferos e aves. Este projeto de pesquisa teve como objetivo principal a caracterização do padrão de expressão dos genes Dpr ao longo do desenvolvimento embrionário de camundongo e com maiores detalhes, a caracterização do padrão de expressão dos genes Dpr durante a ontogênese dos membros em embriões de camundongo e galinha. O padrão de expressão foi determinado através de ensaios de hibridação in situ whole mount e em cortes de parafina. Para permitir comparações, hibridações in situ foram realizadas com marcadores para o desenvolvimento de cartilagem, tendão e músculo. Como resultado, observamos que os genes Dpr são expressos em seis domínios chave (tubérculo genital, membros, focinho, somitos, hérnia umbilical fisiológica e encéfalo) durante o desenvolvimento de camundongo. A análise do padrão de expressão sugere fortemente o envolvimento dos genes Dpr na ontogênese dos membros em embriões de galinha e camundongo. Contudo, a expressão destes genes é bastante diferente entre estes dois organismos. O gene Dpr1 parece estar envolvido com a formação de elementos da articulação e do pericôndrio durante o desenvolvimento dos membros em embriões de camundongo e galinha. O gene Dpr2 possui expressão bastante difusa durante o desenvolvimento dos membros em embriões de camundongo. Em contrapartida, na galinha, Dpr2 possui expressão localizada no blastema dos dígitos e articulações do autópode. O gene Dpr3 possui expressão difusa durante o desenvolvimento dos membros. Apesar disto, os domínios de expressão identificados sugerem que Dpr3 esteja relacionado com o desenvolvimento dos dígitos e articulações / Abstract: Among the molecules involved in molecular signaling during development, those involved in the Wnt and TGF-ß pathways are particularly important. Studies have shown that the Dapper protein family (Dpr) can modulate Wnt and TGF-ß signaling. The Dpr gene family consists of three members: Dpr1, Dpr2 and Dpr3 in zebrafish, mice and humans, and only two: Dpr1 and Dpr2, in birds. Dpr genes have been associated with morphogenetic movements during gastrulation, mesoderm specification, morphogenesis of the brain, heart and eyes. Despite the great relevance of this gene family during development, little is known about the expression pattern of the Dpr genes in mammals and birds. This research project had as main aims to characterize the expression pattern of the Dpr genes during mouse embryonic development and, in more detail, their expression during limb ontogenesis in mouse and chicken embryos. The expression pattern was determined by in situ hybridization in whole mount and in paraffin sections. To allow comparisons, were performed in situ hybridization with markers for the development of cartilage, tendon and muscle. Our results indicate that Dpr genes are expressed in six key areas (genital tubercle, limbs, nose, somites, brain and physiological umbilical hernia) during development of mouse. The expression pattern in the limbs strongly suggests that the Dpr genes work in limbs development in chicken and mouse embryos. However, the expression pattern of these genes is different in these two organisms. Dpr1 seems to be involved in joint and perichondrium formation during limb development in mouse and chicken embryos. For Dpr2, the expression was diffuse during limb development in mouse embryos. In contrast, chicken Dpr2 has localized expression in the digits and joints. Dpr3 gene has diffuse expression during limb development. However, its expression domains suggest that Dpr3 is related to digits and joints development / Mestrado / Biologia Celular / Mestre em Biologia Celular e Estrutural
122

Estudo eletromiografico da ação simultanea de musculos flexores e extensores do antebraço pronado e supinado, em diferentes cargas e angulos

Sousa, Gilmar da Cunha 10 June 1998 (has links)
Orientador: Fausto Berzin / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T17:28:43Z (GMT). No. of bitstreams: 1 Sousa_GilmardaCunha_D.pdf: 20957162 bytes, checksum: 2da116d522ae51ed64ed0ec29a4706f7 (MD5) Previous issue date: 1998 / Resumo: O objetivo deste trabalho foi estudar eletromiograficamente a ação simultânea dos músculos bíceps do braço (cabeças curta e longa), braquial, braquiorradial e tríceps do braço (cabeças lateral, longa e medial), no aparelho de musculação "Polia-Dupla", em movimentos isotônicos de tlexão e extensão do antebraço, nas posições pronada e supinada, em diferentes cargas e ângulos. Foram estudados dez voluntários adultos jovens do sexo masculino, destros, de 16 a 20 anos, altura entre 1,70 e 1,80m, não treinados, sem história de doenças neuromusculares ou articulares. Os registros foram obtidos, utilizando-se um eletromiógrafo de oito canais. Os sinais eletromiográficos foram captados por mini-eletrodos de superfície - Tipo Beckrnan. A análise dos sinais foi efetuada através de software específico, o SISDIN que forneceu os dados numéricos, em RMS (Raiz Quadrada da Média), expressos em microvolts ('mu'V). Foi utilizado um eletrogoniômetro para indicar com precisão os ângulos pré-estabelecidos. Os dados obtidos foram submetidos à análise estatística não-paramétrica, empregandose as provas de Wilcoxon e a de Friedman. Os resultados revelaram que todos os músculos estudados apresentam atividade eletromiográfica, nos movimentos isotônicos de flexão e extensão do antebraço, independente do movimento realizado, posição do antebraço, carga ou ângulo. No movimento livre, os músculos flexores apresentam maior atividade a 90° e os extensores a 60° na posição supinada e, a 30° na pronada. Com carga de 04 Kg e 10 Kg, os músculos flexores desenvolvem maior atividade a 60° na posição pronada, e a 90° na supinada, enquanto os extensores a 30° para as duas posições. Nos movimentos de extensão livre, os músculos flexores apresentam atividade maior do que os próprios extensores, independente da posição do antebraço. Na flexão supinada livre e com cargas de 04 Kg e 10 Kg, a maior atividade é apresentada pela cabeça longa do bíceps. Na flexão pronada livre, a maior atividade é apresentada pela cabeça longa do bíceps. Com cargas de 04 Kg e 10 Kg os maiores potenciais são desenvolvidos pelo braquiorradial. Na extensão supinada livre, a cabeça longa do bíceps desenvolve a maior atividade. Nas cargas de 04 Kg e 10 Kg, esta atividade é observada na cabeça medial do tríceps. Na extensão pronada livre, o braquial apresenta a maior atividade, enquanto que as cargas de 4 Kg e 10 Kg, influenciam a cabeça medial do tríceps a se contrair com maior intensidade. Na flexão supinada, a cabeça longa do bíceps apresenta a maior atividade em quase todas as situações. Na flexão pronada livre, a cabeça curta do bíceps desenvolve a maior atividade a 30°, o braquial a 90°, enquanto a 60° o braquial e a cabeça longa do bíceps mostram a mesma atividade. Entretanto com carga o braquiorradial produz a maior atividade. Na extensão supinada livre, a cabeça curta do bíceps desenvolve a maior atividade a 30°, a cabeça longa a 60° e 90° e, com carga, a cabeça medial do tríceps. Na extensão pronada livre, a atividade mais intensa ocorre no braquial a 90°, no braquiorradial a 60° e na cabeça medial do tríceps a 30°. Com carga, a atividade mais intensa é na cabeça medial do tríceps. Nos movimentos com carga, os músculos agonistas do movimento são sempre mais ativos do que os antagonistas nas duas posições do antebraço estudadas. Quanto maior a carga, maior é a atividade elétrica, tanto nos flexores quanto nos extensores do antebraço, independente do ângulo e posição. Os valores relativos à posição supinada, foram na maioria dos casos mais intensos do que os obtidos na posição pronada / Abstract: The purpose of this work was to study by Electromyography the simultaneous action of the biceps brachii (long and short heads), brachialis, brachiorradialis and triceps brachii (lateral, 10ng and medial heads) muscles through a apparatus of muscular activity called ''DoublePulley" in flexion and extension isotonic movements of the forearm, in supination and pronation, with different loads and angles. Ten adult male young volunteers, aged 16 to 20 years, heighted 1,70m to 1,80m, dextrous, untrained and with no history of neuromuscular or joint diseases were studied. The registers were obtained by using a electromyography equipment with eight channels. The electromyographic signals were captured by surface minielectrodes (Beckman type). The signals were analyzed by a specific software, the SISDIN, which supplied the numerical data in RMS (Root Mean Square), expressed in microvolts ('mu'V). An electrogoniometer was used to indica te the accuracy of the angles previously established. The data obtained were subjected to a non-parametric statistic analysis, using the Wilcoxon and Friedman tests. The results revealed that all the studied muscles presented electromyographic activity in the flexion and extension isotonic movements of the forearm regardless of the performed movement, position of the forearm, load or angle. In the free movement, the flexor muscles presented greater activity at the 90° angle and the extensors at 60° in supination, and at 30° in pronation. With the 4 and 10 kg loads, the flexor muscles presented greater activity at 60° in pronation and at 90° in supination, while the extensors at 30° in both positions. In the free extension movements, the flexor muscles presented greater activity than the extensors themselves, regardless of the forearm position. In the free supinated flexion and with the 4 kg and 10 kg loads, the greatest activity was presented by the biceps long head. In the free pronated flexion, the greatest activity was presented by the biceps long head. With the 4 kg and 10 kg loads, the highest potentials were developed by the brachiorradialis muscle. In the free supinated extension, the biceps long head developed the greatest activity. With the 4 kg and 10 kg loads, this activity was observed in the triceps medial head. In the free pronated extension, the brachialis presented the greatest activity, while the 4 kg and 10 kg loads influence the triceps medial head to contract itself with higher intensity. In the supinated flexion, the biceps long head presented the greatest activity in almost all the situations. In the free pronated flexion, the biceps short head developed the greatest activity at 30°, the brachialis at 90°, while at 60° the brachialis and the biceps long head show the same activity. However, with 1000, the brachiorradialis produces the greatest activity. In the free supinated extension, the biceps short head developed the greatest activity at 30°, the biceps long head at 60° and 90°, and with load, the triceps medial head. In the free pronated extension, the highest activity occurred in the brachialis at 90°, in the brachiorradialis at 60° and in the triceps medial head at 30°. With load, the highest activity was observed in the triceps medial head. In the movements with 1000, the agonist muscles of the movement are always more active than the antagonist muscles in both the studied positions of the forearm. The greater the load, the greater the electric activity, as in the flexors as in the extensors of the forearm, regardless of the angle and position. The values related to supinated position were, in most of the cases, higher than those obtained in the pronated position / Doutorado / Biologia e Patologia Buco-Dental / Doutor em Odontologia
123

Proposição e avaliação de um modelo de representação dos membros superiores e escapula durante a marcha humana / Proposition and evaluation of a model of the upper limbs and scapula representation durang the human gait

Araujo, Alethea Gomes Nardini 12 April 2009 (has links)
Orientador: Ricardo Machado Leite de Barros / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-08-14T03:55:20Z (GMT). No. of bitstreams: 1 Araujo_AletheaGomesNardini.pdf: 1729436 bytes, checksum: 0866174ca722c5ed18e3f01aa5215a5d (MD5) Previous issue date: 2003 / Resumo: A marcha humana é um movimento complexo que integra todos os segmentos corporais. Ela é objeto de pesquisa em laboratórios de todo o mundo e nestes o principal protocolo adotado, protocolo Helen Hays, analisa apenas o movimento dos membros inferiores e pelve e, através da interpretação dos resultados, muitos procedimentos invasivos e/ou conservadores podem ser prescritos. O objetivo geral deste trabalho é propor, avaliar e aplicar modelos de representação biomecânica dos membros superiores e escápula visando a análise de marcha. Um segundo objetivo é integrar os modelos propostos ao protocolo experimental para análise de marcha descrito por ANDRADE (2002). O corpo humano foi modelado como um sistema de quinze corpos rígidos articulados, cada um representando um segmento corporal. A cada segmento foi associado um sistema de coordenadas e a posição e a orientação relativas entre dois segmentos foram descritas, respectivamente, pela translação entre suas origens e pela rotação entre as bases a eles associadas. Os modelos de representação do braço e escápula adotados neste trabalho seguem a recomendação da Sociedade Internacional de Biomecânica. Foram avaliados três voluntários do sexo feminino, sem histórico de patologias ou comprometimento da marcha e dois voluntários do sexo masculino portadores de Paralisia Cerebral Diplégica. Os resultados foram avaliados a partir de testes de acurácia em relação à reconstrução da trajetória de dois marcadores durante a marcha e a acurácia encontrada foi de 2,4mm em um volume calibrado de 4,5m3, o que garantiu a confiabilidade dos resultados. Considerando um ciclo de marcha do membro inferior esquerdo observou-se, nos voluntários normais, que durante a fase de apoio, o ombro direito apresentou aumento da adução, extensão e rotação interna. Durante a fase de balanço, os ângulos mencionados diminuíram. O ombro esquerdo apresentou comportamento simétrico relacionado ao ciclo de marcha. Em relação ao cotovelo, os ângulos de abdução-adução e rotação internaexterna permaneceram constantes em ambos os lados. Um sinal claro de flexão pode ser observado durante todo o ciclo. A análise proposta foi capaz de identificar e caracterizar os padrões de marcha dos voluntários normais. Em relação aos voluntários patológicos, um paciente apresentou um padrão de marcha em crouch e ele revelou um comportamento aproximadamente simétrico considerando os membros superiores do lado direito e esquerdo. O outro paciente apresentou rotação interna aumentada no quadril e pé esquerdo associado a uma rotação do tronco para o lado direito. O cotovelo e o ombro do lado direito apresentaram pequena mobilidade provavelmente para compensar a rotação do tronco para este lado. Os resultados obtidos a partir do protocolo proposto para os sujeitos normais e patológicos foram compatíveis com os dados da literatura em relação aos ângulos articulares dos membros inferiores e da pelve. Os resultados da movimentação dos membros superiores, escápula, tronco e cabeça dos voluntários com e sem alterações da marcha também mostraram coerência com a movimentação esperada pela análise visual e com os dados disponíveis na literatura. / Abstract: The human gait is a complex movement that integrates all body's segments. It is studied in various gait laboratories where the main protocol adopted is the Helen Hays protocol, which considers only the lower limbs and the pelvis movement. With the results obtained from this protocol, respective procedures are prescribed. The aim of this paper is to propose, evaluate and apply models of biomechanical representation of the upper limbs and the scapula, focusing on the gait analysis. The second aim is to integrate the proposed models to an experimental protocol for the gait analysis described by ANDRADE (2002). The human body was modeled as a system of fifteen articulated rigid bodies, each one representing a corporal segment. Each segment was associated to a coordinated system, and the relative position and orientation between two segments were described, by the translation between its origins and the rotation between the bases associated to them. The representation models of the arm and scapula adopted in this paper follow the recommendation of the International Society of Biomechanics. Three female volunteers without gait pathologies and two spastic diplegic cerebral palsy male patients were analyzed. The results were evaluated from the tests of accuracy in relation to the reconstruction of the trajectory of two markers during the gait. The accuracy found was of 2,4mm in a calibrated volume of 4,5m³, thus guarantees the reliability of the results. Considering a left lower limb gait cycle during the stance phase, the right shoulder presented increasing adduction, extension and internal rotation, while during the swing phase these angles decreased. The left shoulder presented a symmetrical behavior related to the gait cycle. Regarding the elbow, the abductionadduction and internal-external rotation angles remain approximately constant in both sides. A clear signal of flexion can be observed during the cycle. The proposed analysis was able to identify and characterize the normal gait patterns of the normal studied subjects. Regarding the pathological subjects, one patient presented a crouch pattern gait and an approximately symmetrical gait by considering the right and left upper limbs. The other patient presented increased internal rotation on the left hip and in the left foot associated to a right rotation of the trunk. The right shoulder and elbow joints have small mobility, probably to compensate the increased rotation of the trunk to this side. The results obtained from proposed protocol for normal and pathological subjects were compatible with literature results concerning lower limbs and pelvis angles. The upper limbs, scapula, trunk and head results from volunteers without and with gait pathologies were coherent with their articulated motion in relation to visual analysis and to another published studies. / Universidade Estadual de Campi / Biodinamica do Movimento Humano / Mestre em Educação Física
124

Comparação entre protocolos de marcadores anatomicos e tecnicos para analise cinematica na marcha e na corrida / Comparison of technical and anatomical markers protocols for kinematical analysis in the walking and in the running

Miana, Andreia Nogueira 08 March 2007 (has links)
Orientador: Ricardo Machado Leite de Barros / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-08-08T23:00:32Z (GMT). No. of bitstreams: 1 Miana_AndreiaNogueira_M.pdf: 1861684 bytes, checksum: 665eaddcfbbcd37b0517005f4dfb680e (MD5) Previous issue date: 2007 / Resumo: O propósito deste trabalho foi comparar dois protocolos para análise cinemática de velocistas em função das velocidades, segmentos corporais e ângulos articulares durante a marcha e a corrida. Um protocolo utiliza marcadores fixados diretamente sobre a pele e outro utiliza marcadores montados sobre estruturas rígidas fixadas no segmento corporal. Seis velocistas do sexo masculino, usando ambos os protocolos, andaram a 5 Km/h e correram a 20 Km/h, em uma esteira ergométrica. Os velocistas foram representados por um modelo tridimensional constituído por quinze segmentos corporais: cabeça, tórax, pelve, pés, pernas, coxas, braços e antebraços. Foram utilizadas oito câmeras de vídeo digital (120 Hz) para aquisição das imagens e a calibração das câmeras e reconstrução das coordenadas 3D dos marcadores foram feitas no software Dvideo®. O tratamento e análise dos dados foram feitos em ambiente Matlab??7.0. Os resultados mostraram que a variabilidade do comprimento dos segmentos e das distâncias entre os marcadores e a diferença máxima entre os ângulos obtidos por cada protocolo foram maiores com o aumento da velocidade, mostrando que os erros na análise do movimento durante a corrida foram maiores que estes durante a marcha. Não houve efeito das velocidades na correlação entre os ângulos obtidos por cada protocolo. A variabilidade da distância entre os marcadores foi maior nos membros inferiores do que nos membros superiores e a variabilidade do comprimento da perna foi maior do que esta nos outros segmentos. Os resultados também mostraram que a maior correlação foi encontrada entre os ângulos de flexão/extensão (0,99) obtidos por cada protocolo e para cada articulação, seguido dos ângulos de adução/abdução (0,78) e dos ângulos de rotação interna/externa (0,65). E os menores valores encontrados na diferença angular máxima foram entre os ângulos de flexão/extensão (6,3° ± 3,4°) obtidos por cada protocolo e para cada articulação, seguido dos ângulos de adução/abdução (13,2° ± 7,9°) e dos ângulos de rotação interna/externa (17,2° ± 8,4°). Os protocolos não apresentaram diferenças na variabilidade do comprimento dos segmentos e também na análise da cinemática angular, porém os ângulos de adução/abdução e rotação externa/interna devem ser observados com mais cautela / Abstract: The purpose of this study was to compare two protocols for kinematical analysis of sprinters according to velocities, body segments and joint angles during walking and running. The first protocol uses retroreflective markers mounted on fixtures attached to the body segment and the second uses retroreflective markers directly located on the skin surface. Six male athletes were studied during treadmill running at 5 and 20 Km/h and recorded with eight 120 Hz video cameras. A three-dimensional model constituted by fifteen segments represented the sprinters: head, thorax, pelvis, the right and left feet, shanks, thighs, scapulas, arms and forearms. The calibration of the cameras, the synchronization of the registrations and the 3D reconstruction of the coordinates of the markers were done in the Dvideo ® software. All data were analyzed using Matlab® 7.0. The results show that the variability of the length of the segments and of the distances between the markers and the maximum difference maximum between the angles obtained by each protocol were higher with the increase of the velocities, showing that the errors in the analysis of the movement during the running were larger than these ones during the gait. There was no effect of the velocities in the correlation between the angles obtained by each protocol. The variability of the distances between the markers in the lower limb were higher than this one in the upper limbs and the variability of the length of the shank was higher than this one in the other segments. The results also showed a higher correlation was found between the flexion/extension angles (0,99) obtained by each protocol and for each joint, followed by the abduction/adduction angles (0,78) and the angles of internal/external rotation (0,65). The lower values found in the maximum angular difference were between the flexion/extension angles (6,3° ± 3,4°) obtained by each protocol and for each articulation, followed by the abduction/adduction angles (13,2° ± 7,9°) and the angles of internal/external rotation (17,2° ± 8,4°). No differences were found in the variability of the length of the segments and also in the analysis of the angular kinematics, however the adduction/abduction and internal/external rotation angles should be regarded with much more caution / Mestrado / Biodinamica do Movimento Humano / Mestre em Educação Física
125

Analise cinematica da movimentação dos membros superiores e inferiores, tronco e cabeça durante a marcha de hemipareticos / Kinematic analysis of upper and lower limbs, trunk and head motions during hemiparetic gait after stroke

Carmo, Aline Araujo do 15 August 2018 (has links)
Orientador: Ricardo Machado Leite de Barros / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-08-15T02:48:57Z (GMT). No. of bitstreams: 1 Carmo_AlineAraujodo_M.pdf: 1636690 bytes, checksum: dca1704fc78e376b3a7a1a58a242c0c7 (MD5) Previous issue date: 2009 / Resumo: O objetivo deste trabalho foi analisar integradamente a cinemática da movimentação dos membros superiores e inferiores, a partir cinemática angular, das variáveis espaço-temporais, do centro de massa total do corpo e das contribuições parciais dos segmentos para a trajetória do centro de massa total do corpo. A fim de identificar e analisar as alterações dos padrões de marcha desenvolvidos pelos sujeitos hemiparéticos acometidos por Acidente Vascular Encefálico. Para isso, foram analisados 14 sujeitos hemiparéticos acometidos por Acidente Vascular Encefálico, do sexo masculino, faixa etária entre 40 e 60 anos, com mínimo de 3 anos pós-lesão e, que não utilizassem dispositivos auxiliares. Para representar a marcha normal, foram selecionados 7 sujeitos do sexo masculino, faixa etária entre 40 e 60 anos, sem alterações na marcha. Os dados foram obtidos por videogrametria através do sistema DVideo. O modelo de orientação dos segmentos corporais utilizado consistiu de 71 marcadores de superfície, considerando 15 segmentos corporais articulados. O tratamento dos dados foi feito em ambiente Matlab. A análise estatística foi baseada nas seguintes comparações: 1) entre os lados direito e esquerdo dos sujeitos do grupo controle e do lado afetado e não afetado do grupo hemiparético; 2) Comparação entre os grupos controle e hemiparético; 3) Comparação das variáveis angulares contínuas das articulações afetadas e não afetadas do grupo hemiparético e as variáveis do grupo controle 4) Comparação da trajetória do centro de massa total e das porcentagens de contribuição parcial dos segmentos corporais entre os sujeitos do grupo controle e hemiparético (P<0.05). Os resultados mostraram que a movimentação do membro superior afetado é significativamente alterada, apresentando redução da amplitude de movimento de flexão/extensão das articulações glenoumeral e cotovelo, associada a um padrão de acentuada flexão do cotovelo e tendência a rotação durante todo o ciclo. Foram detectadas também, alterações significativas nos três planos de movimento dos membros inferiores e variáveis espaço-temporais que corroboram com os achados da literatura. A análise integrada mostrou que as alterações do padrão de marcha de sujeitos hemiparéticos podem estar relacionadas com os distúrbios na movimentação do membro superior afetado, podendo este ser mais um fator agravante para a mecânica da marcha de hemiparéticos. A análise da trajetória do centro de massa total do corpo mostrou que nas direções lateral e vertical as curvas dos sujeitos hemiparéticos foram aproximadamente sinusoidais, com dois picos de diferentes amplitudes, associados a um menor deslocamento ântero-posterior do centro de massa total durante a marcha de hemiparéticos. As porcentagens de contribuição dos segmentos corporais para a trajetória centro de massa total do corpo mostraram que o tronco contribuiu mais para o deslocamento lateral do centro de massa e, na vertical os segmentos perna e pé do lado afetado contribuiram mais para o menor deslocamento vertical do centro de massa. As alterações na direção da progressão são oriundas da combinação dos distúrbios observados na outras duas direções. / Abstract: The aim of this study was to analyze integrally the movement of upper and lower limbs, trunk and head using the following kinematics variables: joint angles, spatiotemporal variables, trajectory of total body center of mass and partial contributions of the segments for the trajectory of total body center of mass. In order to identify and analyze the gait pattern alterations developed by hemiparetic subjects affected by stroke, were analyzed 14 hemiparetics subjects, males, aged between 40 and 60 years old, who presented at least 3 years post-injury, and no walking aids used. To represent the normal gait were selected 7 able-bodies subjects, males, aged between 40 and 60 years old, without gait deviations. The data was obtained by videogrammetry through the DVideo system. The body segments orientation model used on this study consisted in 71 surface markers, whereas 15 articulated body segments. The data processing was done by Matlab software. The statistical analysis was based on the following comparisons: 1) right and left sides of the control group subjects and between the affected and unaffected sides of the hemiparetic group; 2)Comparisons between hemiparetic group and control group; 3) Continuous angle variables comparisons between the affected hemiparetic side versus control group and unaffected hemiparetic side versus control group; 4) Comparisons of the trajectory of total body center of mass and the percent of partial contributions of body segments between control group versus hemiparetic group (P<0.05). The results showed that the affected upper limb movement was significantly altered, with reduced flexion/extension range of motion in the glenohumeral and elbow joints, and it was associated with the elbow joint flexion and rotation tendency throughout the gait cycle. Were also detected significant changes on the three lower limbs movement planes and spatiotemporal variables that agree with the literature findings. The integrated analysis showed changes in stroke gait pattern could be related to the affected upper limb movement disturbances. This is another aggravating factor on the stroke gait pattern. The analysis of the trajectory of total body center of mass showed that the lateral and vertical directions curves of hemiparetic subjects were approximately sinusoidal, with two peaks of different amplitudes, associated with a lower anterior-posterior displacement of the total body center of mass during gait of hemiparetic. The percentual contribution of body segments for the trajectory of total body center of mass showed that the trunk contributed more to the lateral center of mass, and in vertical direction the leg and foot on the affected side contributed more to lower vertical displacement of center of mass. In the lateral direction the lower limbs compensed the upper limbs reduction.Changes in the direction of progression come from the combination of the disturbances observed in the other two directions. / Mestrado / Biodinamica do Movimento Humano / Mestre em Educação Física
126

Análise Biomecânica da Inicialização da Marcha de Amputados Transtibiais Protetizados / Biomechanical Analysis of the startup of gait of transtibial amputees prostheses

AVELAR, Ivan Silveira de 30 March 2012 (has links)
Made available in DSpace on 2014-07-29T15:29:14Z (GMT). No. of bitstreams: 1 Analise Biomecania da Inicializacao da Marcha de Amputados Transtibiais Protetizados.pdf: 3970642 bytes, checksum: afbedb9e27d84f4cdd22ab374f81a8c5 (MD5) Previous issue date: 2012-03-30 / The amputee patient undergoes several changes after the amputation, not only physical but also emotional and socioeconomic, requiring the use of prosthesis. One of the physical changes that affects the amputee's gait when using your prosthesis ambulation is compromised. The march is the natural way that humans use to move from one location to another. The march is a complex activity because it depends on a series of interactions between the two lower limbs multithreaded and total body mass. Therefore, assessing the impact of the use of prostheses in locomotor through the analysis of strategies for startup of the march transtibial amputees. We evaluated the speed and displacement of the COP, knee and ankle angles of the support member during initialization of the march. For the kinematic analysis was set 34 markers on anatomical landmarks of interest, two AMTI force platforms. For statistical analysis we used the Student t test and correlation between variables. Difference was only statistically significant variables in the knee angle and average speed side. The absence of a flexible ankle joint may result in limitations in the function of the prosthesis. Amputees to achieve an adequate control in propulsion and balance it was necessary to use several strategies to adjust. The prosthesis provided by SUS serves its purpose, which is to provide a walking person. But this improvement in the ankle joint can facilitate the process of walking boot. Another fact of great importance is the frequent evaluation of prosthetic to verify the necessary adjustments of the prosthesis. / O paciente amputado sofre várias alterações após a amputação, não somente físicas, mas também emocionais e socioeconômicas, sendo necessário que a utilização de prótese. Uma das alterações físicas que acomete o amputado é a locomoção quando da utilização de prótese a sua deambulação fica comprometida. A marcha é o meio natural que o ser humano utiliza para se deslocar de um local para outro. A marcha é uma atividade complexa porque depende de uma série de interações entre os dois membros inferiores multissegmentados e a massa total do corpo. Assim sendo, avaliar o impacto da utilização de prótese no aparelho locomotor por meio da análise das estratégias de inicialização da marcha em amputados transtibiais. Foram avaliados a velocidade e deslocamento do COP, ângulos do joelho e tornozelo do membro de apoio durante a inicialização da marcha. Para a análise cinemática foi fixado 34 marcadores em pontos anatômicos de interesse, mais duas plataformas de força AMTI. Para a análise estatística foi utilizado o test t de Student e a correlação entre as variáveis. Foi encontrada diferença estatística somente nas variáveis ângulo do joelho e velocidade médio lateral. A ausência de uma articulação do tornozelo flexível pode resultar em limitações na função da prótese. Os amputados para alcançar um adequado controle na propulsão e equilíbrio houve a necessidade a utilização de várias estratégias de ajustamento. A prótese fornecida pelo SUS atende o seu propósito, que é fornecer uma deambulação ao indivíduo. Porém a melhoria desta na articulação do tornozelo pode facilitar o processo de inicialização da marcha. Outro fato de grande importância é a freqüente avaliação do protetizado a fim de verificar os ajustes necessários da prótese.
127

Avaliação do efeito da meia elástica na hemodinâmica venosa dos membros inferiores de corredores / Evaluation of the effect of compression stockings in venous hemodynamic of the lower limbs of runners

Oswaldo Teno Castilho Junior 02 October 2015 (has links)
RESUMO Castilho Junior, O T. Avaliaço do efeito da meia elástica na hemodinâmica venosa dos membros inferiores de corredores. 2015. 71f. Dissertação (Mestrado) - Faculdade de Medicina Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto - SP. Introdução: A literatura médica a respeito da eficácia e dos benefícios do uso de meias elásticas de compressão graduada (MECG) na corrida é controversa e inconclusiva. Objetivo: O objetivo foi verificar as alterações da hemodinâmica venosa dos MMII pela pletismografia a ar (PGA) , do lactato sanguíneo e da resposta clínica provocadas pela corrida em atletas amadores saudáveis sem e com o uso de MECG. População e Método: Dez atletas (4 homens e 6 mulheres), corredores voluntários, com idade média 40,3 anos, índice de massa corporal (IMC) médio de 21,88, foram submetidos a avaliações de parâmetros hemodinâmicos venosos por meio da PGA (IEV-índice de enchimento venoso; FE-fraço de ejeção e FVR-fração de volume residual), dosagem de lactato capilar e avaliação clínica (frequência cardíaca, dor e conforto nos MMII) em 3 situações: em repouso (antes da corrida); logo depois de uma corrida de 10 km em esteira com inclinação de 1% sem o uso de MECG e uma semana após com o uso de MECG. Todas as variáveis foram analisadas estatisticamente e considerou-se 5% o nível de significância. Resultado: Após a corrida houve elevação significativa dos valores de IEV dos MMII no grupo sem em relação ao grupo com MECG e em repouso. Houve queda significativa da FVR do membro inferior direito no grupo com MECG em relação aos grupos em repouso e sem meia elástica, o que não ocorreu no membro inferior esquerdo. A FE foi semelhante em todas as situações. O lactato elevou-se no final da corrida no grupo sem MECG e notou-se tendência a elevação no grupo com MECG, mas a diferença inicial e final do lactato nas duas situações permaneceu semelhante. As manifestações clínicas (frequência cardíaca , dor, conforto e lesões) foram semelhantes em todas as situações após a corrida sem e com MECG. Conclusão: Apesar de inalteradas as manifestações clínicas ( frequência cardíaca, dor e desconforto) e dos níveis de lactato de corredores amadores, sadios, após a corrida de 10km com inclinação de 1%, o uso de MECG teve efeitos positivos na hemodinâmica venosa dos MMII, aferidos pela PGA e caracterizados pela redução do IEV em ambos os membros e pela queda da FVR, pelo menos no membro inferior direito. / Background: The literature about the efficacy and the benefits of wearing compression stockings (CS) in running is controverse and inconclusive. Objective: The objective was to verify the changes of venous hemodynamic parameters of the lower limbs measured by air pletismography (APG), of the capillary lactate and of some clinical aspects promoted by running in normal healthy runners wearing or not compression stockings. Methods: Ten volunteer runners (4 men, 6 women), mean age 40,3 years, mean corporal mass index of 21,88, were submitted to evaluation the hemodynamic parameters measured by APG (venous filling index VFI; ejection fraction EF and residual venous fraction - RVF), measurement of capillary lactate and clinical aspects (cardiac frequency, pain, comfort and lesions) in 3 situations: at rest (before running); after a 10 Km running on a treadmill with 1% inclination degree without CS and a week later, after the same running wearing compression stockings. All variables were statistically analised and it was considered 5% as the significance level. Results: After running there was significant elevation of the VFI in the group without CS compared to the groups at rest and with CS. There was also a meaning descent of the RVF levels of the right lower limb of the volunteers wearing CS compared to those without CS and at rest, but this was not noticed on the left lower limb. The EF was the same in all situations. The lactate levels increased after running without CS and there was a tendency of elevation with the use of CS, but the initial and final differences in both situations remained the same. The clinical aspects (cardiac frequency, pain, comfort and lesions) were similar after running with or without CS. Conclusion: Although there were no changes of the clinical aspects (cardiac frequency, pain, comfort and lesions) and the lactate levels of healthy amateur runners after a 10 Km running on a treadmill with a 1% elevation degree, APG showed that the use of CS promoted beneficial effects on venous hemodynamics of the lower limbs, featured by the fall of the VFI levels on both lower limbs and the fall of the RVF levels on the right lower limbs.
128

Avaliação do desempenho comercial do Mercosul: 1994 - 2005 / Evaluation of Mercosul\'s Trade Performance: 1994 - 2005

Luciana Aparecida Bastos 05 February 2009 (has links)
Esta Tese consiste em avaliar o desempenho comercial do Mercosul, no período de 1994- 2005. O intuito da mesma é verificar de que maneira as crises internacionais da década de 1990, bem como as crises conjunturais e estruturais das economias-membro, influenciaram no desempenho do comércio intra e extra-regional das mesmas, a saber: Argentina, Brasil, Paraguai e Uruguai, nesse período. / This thesis consists of evaluating the Mercosur commercial performance from 1994 to 2005. It aims to verify both the form in which the 90s decade international crisis as well as the junctural and structural bodywork crisis affected the internal and external regions of Mercosur economies trade performance such as: Argentine, Brazil, Paraguay and Uruguay during the period mentioned above.
129

Efeitos da eletroestimulação neuromuscular no musculo tibial anterior de pacientes hemipareticos espasticos

Nunes, Ligia Christina Borsato Guimarães 15 July 2004 (has links)
Orientador: Antonio Augusto Fasolo Quevedo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-03T23:45:03Z (GMT). No. of bitstreams: 1 Nunes_LigiaChristinaBorsatoGuimaraes_M.pdf: 1112094 bytes, checksum: e491810518ee66305badb8d9c43312c2 (MD5) Previous issue date: 2004 / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
130

Projeto e construção de parte estrutural de protese de mão humana com movimentos / Design and fabrication of a mobile part of a human hand prothesis

Polis, João Eduardo 14 August 2018 (has links)
Orientador: Cecilia Amelia de Carvalho Zavaglia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-14T13:19:50Z (GMT). No. of bitstreams: 1 Polis_JoaoEduardo_M.pdf: 6036142 bytes, checksum: dadf234cb5c40223223dbe5c453fce7a (MD5) Previous issue date: 2009 / Resumo: Devido ao grande número de pessoas que necessitam do uso de prótese para substituir um membro com seu funcionamento normal afetado, seja por deficiência congênita ou nos casos em que haja necessidade de remoção, ocasionada por doenças ou lesões com trauma, como acidentes do trabalho e de trânsito, foi desenvolvido neste trabalho o projeto e construção da parte estrutural de uma prótese de mão humana, com dimensões e movimentos mecânicos em similaridade (física) com o membro original. Em analogia com uma máquina, a mão é uma ferramenta terminal com atuadores exercendo várias funções como preensão de objetos, movimentação, sensibilidade à textura e temperatura. Entre os membros superiores, é o mais utilizado, exposto e complexo, que quando demanda sua substituição por uma prótese encontra obstáculos em várias áreas, desde aspectos tecnológicos, morfológicos, psicológicos e ainda financeiros. O mercado mundial de próteses dispõe de modelos com tecnologia avançada, que oferecem grande gama de recursos, mas por se tratar de um produto que ainda não é produzido em larga escala, que possui componentes de alta tecnologia e alto custo, não atinge o grande número de pessoas que necessitam da sua utilização. A pesquisa desenvolvida neste trabalho adotou uma metodologia de projeto que buscou a facilidade de construção e a utilização de componentes e matérias-primas disponíveis no mercado e de custo relativamente baixo, podendo assim desenvolver a base estrutural de um produto em desenvolvimento, que incorporará em suas etapas futuras as áreas de motorização, sensorização e revestimento cosmético, visando a obtenção de uma prótese de mão humana que realize movimentos atendendo a impulsos mioelétricos gerados pelo paciente, e que seu custo final de construção, variedade de movimentos e praticidade na colocação viabilizem sua utilização por um maior número de pessoas. / Abstract: The number of handicapped people in need of a particular kind of prosthesis is a compelling reason for carrying out this study, for developing a design and fabrication of a human forelimb prosthesis with dimensions and mechanical movements in similarity (physical) with a human hand. Some of theses handicaps may be a result of accidents, congenital diseases, injuries, or even amputations. Analogous to a machine, a hand is a sensitive terminal tool that is able to grip, move, feel and measure temperatures of objects. It is a very useful and complex member of the human body, and when is necessary to replace it with a prosthesis, there are technological, morphological, psychological and also financial barriers. The world market of prosthesis offers high technology models and a very wide range of resources. However, these products are made of expensive hi-tech components. Moreover, most people cannot afford to buy these expensive products because there is still no large-scale production. Thus, this research project aims at building a prosthetic forelimb with dimensions and mechanical movements similar to those of the human hand, using relatively low cost components and raw materials for manufacturing the final product. This new prosthesis has sensitized "nerve" endings, cosmetic coating, and it is also motorized. It responds to myoelectric impulses generated by the patient. In addition, it is cheap, practical, and it has a variety of movements witch allow it to be used by a large number of people. / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica

Page generated in 0.0762 seconds