• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69
  • 67
  • 13
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 163
  • 68
  • 68
  • 41
  • 33
  • 33
  • 31
  • 25
  • 18
  • 18
  • 17
  • 17
  • 16
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Conception d’un circuit de lecture à étampes temporelles multiples pour un photodétecteur destiné à la tomographie d’émission par positrons

Lemaire, William January 2018 (has links)
La médecine moderne fait usage de divers appareils pour faciliter le diagnostic et le traitement des maladies. Parmi ceux-ci, l’imagerie par tomographie d’émission par positrons (TEP) se démarque par sa capacité d’imager des processus biologiques spécifiques comme le métabolisme du glucose. Cette caractéristique permet de mettre en évidence des signes distinctifs des maladies comme le cancer à l’aide de radiotraceurs capables de cibler certaines cellules. Dans le but de favoriser de meilleurs diagnostics et de mener des recherches de pointe dans le domaine médical, la qualité des images produites par les appareils TEP doit être améliorée. Les avancées des dernières années ont permis d’améliorer la résolution spatiale des images jusqu’à pratiquement atteindre la limite théorique imposée par le déplacement du positron lors du processus de désintégration. Depuis, les travaux s’orientent plutôt vers l’amélioration du contraste de l’image en intégrant la mesure du temps de vol (TdV) dans l’algorithme de reconstruction. Le défi dans cette mesure réside dans la conception d’un photodétecteur avec une résolution temporelle suffisante pour localiser le lieu d’émission du radiotraceur entre deux détecteurs coïncidents. La plupart des photodétecteurs actuels utilisent un seuil sur le nombre de photons de scintillation observé pour déterminer le temps d’arrivée des photons d’annihilation dans le scintillateur. Cependant, plusieurs travaux ont démontré qu’une meilleure résolution temporelle est atteignable en pondérant adéquatement l’information temporelle numérisée de plusieurs photons de scintillation à la place de n’en considérer qu’un seul. Dans le but d’améliorer la résolution temporelle des photodétecteurs, l’utilisation d’un estimateur statistique combinant l’information de plusieurs photons de scintillation se révèle une méthode prometteuse en considérant les résultats théoriques. Cependant, une implémentation matérielle pouvant être intégrée à un appareil TEP reste à être démontrée. Les travaux de recherche présentés dans ce mémoire portent sur l’intégration d’un tel estimateur statistique à un photodétecteur pour la TEP. Ces travaux ont mené au développement d’une chaine d’acquisition qui comporte 1) un circuit de lecture, 2) une trieuse, 3) un filtre de bruit thermique et 4) un estimateur statistique du temps d’interaction basé sur le Best Linear Unbiased Estimator (BLUE). L’intégration de cette chaine à même le circuit intégré du photodétecteur de 1 x 1 mm2 en CMOS 65 nm permet de réduire la bande passante de 250 Mbit/s à 0,5 Mbit/s et le temps mort de 68,6 μs à 1024 ns. Des simulations démontrent l’atteinte d’une résolution temporelle qui s’approche de la limite inférieure théorique (appelée borne de Cramér-Rao) quant à la résolution temporelle atteignable par ce photodétecteur.
142

Chambre d'ionisation liquide détecteur de photons γ pour l'imagerie TEP / Liquid ionization chamber detector of γ photons for PET imaging

Farradèche, Morgane 02 July 2019 (has links)
CaLIPSO est un concept de détecteur de photons pour la Tomographie par Émission de Positrons dédiée au cerveau. Il s'agit d'une technique d'imagerie médicale reposant sur la détection en coïncidence de deux photons de 511 keV. Pour la première fois, le triméthylbismuth liquide est utilisé comme milieu de détection. Chaque photon de 511 keV libère un électron primaire qui émet des photons Cherenkov et ionise le milieu. CaLIPSO fonctionne sur le principe d'une chambre à projection temporelle et détecte à la fois la lumière Cherenkov et le signal de charge. Le nombre total de charges libérées étant proportionnel à l’énergie déposée par le photon incident, nous avons pu mesurer le rendement de production de charge du triméhylbismuth. Pour cela, nous avons développé un système d'ultra-purification du liquide associé à un système de mesure bas bruit du courant induit par une source de photons γ avec une précision < 5 fA pour un champ électrique allant jusqu'à 7 kV/cm. Le tétraméthylsilane a été utilisé comme liquide de référence pour valider la mesure. Nous avons obtenu un rendement de production de charge du triméthylbismuth inférieur d'un facteur 6 aux valeurs typiques des liquides diélectriques similaires. Des calculs de chimie quantique sur atomes lourds ont permis de montrer que ce comportement est dû à la géométrie de la molécule de triméthylbismuth. L'atome de bismuth se comporte comme un centre de capture des électrons qui induit un mécanisme de recombinaison supplémentaire des électrons près de leurs cations parents. Enfin, afin de vérifier cette hypothèse et de quantifier la mobilités des charges dans les liquides, nous avons développé un système de mesure d'impulsions de charge individuelles qui a été validé avec succès avec le tétraméthylsilane. / CaLIPSO is a photon detector concept designed for dedicated brain Positron Emission Tomography. It is a medical imaging technique based on the coincidence detection of two 511-keV photons. For the first time, the liquid trimethylbismuth is used as sensitive medium. Each 511-keV photon releases a primary electron that triggers a Cherenkov radiation and ionizes the medium. CaLIPSO operates as a time projection chamber and detects both Cherenkov light and charge signal. As the total number of released charges is proportional to the energy deposited by the initial photon, we were able to measure the charge production yield (or free ion yield) of the trimehylbismuth. To this end, we developed a purification bench associated with a low-noise measurement system for the current induced by a γ-ray source of photons with a precision < 5 fA for an electric field up to 7 kV/cm. The tetramethylsilane was used as a benchmark liquid to validate the measurement. We obtained a free ion yield of trimethylbismuth 6 times lower than the typical values for similar dielectric liquids. Quantum chemistry computations on heavy atoms shown that this behavior is due to the geometry of the trimethylbismuth molecule. The bismuth atom acts as an electron trapping center which induces an additional recombination mechanism of the electrons near their parent cations. Finally, in order to verify this hypothesis and to quantify the mobility of charges in liquids, we developed an individual charge pulses measurement system which has been successfully validated with tetramethylsilane.
143

Caractérisation clinique et par la tomographie d’émission par positrons quantitative du trouble de l’acquisition de la coordination / Clinical and quantitative positron emission tomography characterization of lower case

Farmer, Marie January 2016 (has links)
Résumé : Le trouble de l’acquisition de la coordination (TAC), d’étiologie encore indéterminée, est une anomalie neurologique affectant environ 6% des enfants de l'âge scolaire. Le TAC se manifeste essentiellement par un déficit au niveau des exécutions motrices. Le présent travail de recherche comporte deux volets portant sur le TAC. Premièrement, une étude clinique sur 129 sujets âgés de 4 à 18 ans a permis de classifier les caractéristiques du TAC en sous-groupes cliniques. Trente-trois caractéristiques du TAC, les plus fréquemment rapportées dans la littérature, ont été recensées chez nos sujets. L'application d'évaluations statistiques a permis de faire ressortir trois classes essentielles. Le deuxième volet consistait à identifier les régions cérébrales impliquées dans une tâche motrice à l'aide de l'imagerie par la tomographie d'émission par positrons (TEP). Deux sujets avec TAC et deux sujets normaux ont été étudiés en deux séances d'imagerie TEP dont l'une au repos et l'autre en tapotant du pouce sur les doigts de la main gauche non-dominante. Les analyses du premier volet ont montré, entre autres, que le TAC touchait 3.17 garçons pour une fille, que tous les sujets étaient lents, que 47% des sujets étaient gauchers ou ambidextres alors que seulement 10% sont gauchers dans la population générale, que 26% avaient une dyspraxie verbale, et que 83% avaient été diagnostiqués anxieux. Les sujets ont été classés en trois sous-groupes: 1- maladroits et autres caractéristiques, sans problème de langage; 2- trouble de l’estime de soi et relation avec les pairs; 3- difficulté de langage. En imagerie, les structures cérébrales ont été classées selon leur captation du 18F-fluorodesoxyglucose (FDG) dans les hémisphères droit et gauche, avant et après l'activation, et en comparaison avec les sujets normaux. Trois types de structures cérébrales sont ressortis avec les statistiques: des structures activées, celles relativement non sollicitées et des structures désactivées. Il y avait plus de variations dans la captation du FDG chez les sujets avec TAC que chez les normaux. En conclusion, la caractérisation des sujets avec TAC par le diagnostic clinique et par l'imagerie peut procurer un plan de thérapie adéquat et ciblé étant donné que le TAC a un large spectre et pourrait coexister avec d'autres déficits cérébraux. / Abstract : Developmental Coordination Disorder (DCD) is a neurological abnormality affecting approximately 6% of children of school age. DCD is essentially manifested by deficit in motor executions. The present research aims two parts of DCD. First, a clinical study on 129 subjects aged 4 to 18 years old allowed to classify DCD characteristics (subtyping) in three classes. Thirty-three features of DCD, the most frequently reported in literature, have been identified in our subjects. The application of statistical clustering produced three essential classes. The second part was to identify the brain regions involved in a motor task using positron emission tomography (PET) imaging. Subjects with DCD and control subjects were studied in two PET imaging sessions at rest and then by tapping the thumb on each finger of the left non-dominant hand. The results showed, that DCD concerned 3.17 boys for one girl, all subjects were slow, 47% of the subjects were left-handed or ambidextrous while only 10% are left-handed in general population, 26% had a verbal dyspraxia, and 83% had been diagnosed with anxiety. Subjects were classified into three groups: 1- clumsy and other features without language problem; 2- self-esteem and peer relationships concern; 3- difficulty of spoken language. With PET imaging, the brain structures were classified according to their uptake of 18F-fluorodeoxyglucose (FDG) in the right and left hemispheres before and after activation, and compared with normal subjects. Three types of brain structures statistically emerged: activated structures, those relatively unsolicited and those disabled. There was more variation in uptake of FDG in patients with DCD than in control subjects. In conclusion, the characterization of subjects with DCD for clinical diagnostic and imaging can provide adequate and focused treatment plan since DCD has a broad spectrum and could coexist with other brain deficits.
144

Étude des effets de l'adénosine sur le remodelage ventriculaire gauche survenant après un infarctus du myocarde / Study of the effects of adenosine on left ventricular remodelling

Bousquenaud, Mélanie 18 July 2012 (has links)
Le remodelage ventriculaire est un processus réactionnel pouvant faire suite à un infarctus du myocarde (IDM), évènement ischémique aigu survenant lors de l'obstruction d'une artère coronaire. Le remodelage provoque alors des changements géométriques et fonctionnels du tissu myocardique qui permettent de maintenir et d'adapter la fonction cardiaque. Lorsque ce processus est délétère, la maladie évolue vers l'insuffisance cardiaque, ce qui altère le pronostic et la qualité de vie des patients. L'adénosine est un nucléoside ubiquitaire dont les effets sur le remodelage ventriculaire après IDM sont encore peu connus et dépendent du type de récepteur activé. Au sein de notre laboratoire, de précédentes études in vitro ont montré que l'adénosine régule de nombreux acteurs clés du remodelage. Dans ce travail de thèse, nous avons émis l'hypothèse que l'adénosine pouvait avoir un effet bénéfique sur le remodelage ventriculaire après la survenue d'un IDM. Dans un premier temps, nous avons montré que la tomographie par émission de positrons (TEP) permet de caractériser précisément les séquelles d'IDM et de prédire le remodelage ventriculaire chez le rat après occlusion coronaire. Cette technique nous a permis de mettre en évidence le cas d'un rat ayant survécu à un IDM touchant plus de 70% de son ventricule gauche. Dans un deuxième temps, nous avons montré que l'administration chronique d'adénosine, à long terme après IDM chez le rat, permet de maintenir la contractilité cardiaque dans la zone bordant l'IDM. Cet effet cardioprotecteur peut s'expliquer par une stimulation de l'angiogenèse elle-même due à un recrutement de cellules endothéliales progénitrices circulantes. Ensuite, nous avons montré que la chimiokine Monocyte Chemotactic Protein 3 est capable de stimuler la migration des cellules endothéliales progénitrices et est ainsi un agent thérapeutique potentiel après IDM. Enfin, nous avons commencé l'étude préclinique d'une molécule agoniste du récepteur A2A à l'adénosine et antagoniste du récepteur A3, un candidat particulièrement prometteur pour prévenir le remodelage ventriculaire après IDM / Left ventricular (LV) remodeling can follow myocardial infarction (MI), an acute ischemic event which occurs after occlusion of a coronary artery. Remodeling allows maintaining and adapting cardiac function by geometric and functional changes of the myocardium. If this process becomes maladaptive, the patients? prognostic and life quality are impaired by the development of heart failure. Adenosine is an ubiquitous nucleoside with partially characterized effects on LV remodeling. These effects depend on the type of receptor activated. Previous in vitro studies from our laboratory have shown that adenosine regulates several key processes involved in LV remodeling. Here, we hypothesized that adenosine may have beneficial effects on LV remodeling after MI. First, we showed that positon emission tomography (PET) can accurately characterize MI severity and predicts subsequent LV remodeling in the rat model of MI induced by coronary occlusion. Using this technique, we described the case of a rat that survived after a massive infarct covering 70% of the left ventricle. Second, we showed that a chronic administration of adenosine preserves cardiac contractility in the border zone, two months after MI. This cardioprotective effect can be explained, in part, by the stimulation of angiogenesis involving a stimulation of the recruitment of endothelial progenitor cells to the heart. Then, we showed that the Monocyte Chemotactic Protein 3 stimulates the migration of endothelial progenitor cells and is thereby a potential therapeutic target after MI. Finally, we started the preclinical study of an A2A agonist / A3 antagonist, a promising candidate to prevent LV remodeling after MI
145

Quality control of PET camera for small animal imaging / Έλεγχος ποιότητας κάμερας PET για απεικόνιση μικρών ζώων

Ευθυμίου, Νικόλαος 06 February 2009 (has links)
- / The term Molecular Imaging (MI) can be broadly defined as the in vivo characterization and measurement of biological processes at the cellular and molecular level. In contradistinction to “classical” diagnostic imaging, it sets forth to probe the molecular abnormalities that are the basis of disease rather than to image the end effects of these molecular alterations. The underlying biology represents a new arena for many researchers. A number of technological challenges such as signal amplification, data and image processing and efficient imaging strategies, provide a fast growing scientific domain. Positron Emission Tomography (PET), Magnetic Resonance Imaging (MRI), Single Photon Emission Tomography (SPECT) and optical imaging are the main tools of clinical molecular imaging. Nuclear medicine techniques (SPECT and PET) are key players in MI. New radiopharmaceutical products are currently being developed, in order to increase the specificity and sensitivity of existing imaging techniques. Small animal imaging is the main tool for the evaluation of those derivatives, especially in dynamic in vivo studies. In this, preclinical part, high resolution and high sensitivity imaging equipment is necessary; as a result a number of such prototypes have been developed worldwide and some of them are commercialized. However, there cost is usually not affordable for small or medium size laboratories. In this work a low cost dual head PET camera, suitable for high resolution small animal studies has been developed. It is the result of the collaboration between Jefferson lab and Technological Educational Institute of Athens (TEI) and is currently evaluated in Institute of Radioisotopes and Radiodiagnostic Products (IRRP), in “Demokritos” Center. The system has a field of view of 5x5cm and is based on 2 H8500 position sensitive photomultiplier tubes (PSPMTs), coupled to two LSO crystals with 2.5x2.5mm pixel size. Then an FPGA based data acquisition system and proper data reconstruction system collect events, sort coincidences and produce images. The DAQ board consists of 16-channel DAQ modules installed on a USB2 carrier. Each channel is an independent acquisition system consisting of traditional analog pulse processing, FPGA analog control, and FPGA signal processing. After acquisition and processing, channel data are assembled into event blocks for readout by the carrier board. Application specific tasks are performed in JAVA using the Kmax interface. The GUI was designed to be easy-to-use. In order to further analyze images and process the results proper algorithms were developed in MATLAB and ImageJ. Systems evaluation has been carried out using FDG. Point sources have been used for systems calibration. Capillaries with 1.1mm inner diameter were imaged and used for resolution calculation. Finally a mouse injected with 100μCi of FDG was imaged. Spatial resolution has been measured using thin capillaries (1.1mm inner diameter) and found equal to 3,5mm in planar mode. This lower limit is determined by LSO pixels size (2.5×25mm2). Simulation studies have shown that resolution lower than 2mm will be achieved in tomographic mode. Mice injected with FDG are presented. Brain and heart are clearly imaged. Currently, a rotating base is constructed, in order to upgrade the system to a tomographic PET. PET results will be presented as well. In addition, IRRP and TEI are working on new radiopharmaceuticals based on Cu-64. It must be stated that PET market opened in Greece four years ago; This system is the first working small PET prototype in Greece and it initiates national preclinical PET research.
146

Conception d'un circuit d'étouffement pour photodiodes à avalanche en mode Geiger pour intégration hétérogène 3D

Boisvert, Alexandre January 2014 (has links)
Le Groupe de Recherche en Appareillage Médical de Sherbrooke (GRAMS) travaille actuellement sur un programme de recherche portant sur des photodiodes à avalanche monophotoniques (PAMP) opérées en mode Geiger en vue d'une application à la tomographie d’émission par positrons (TEP). Pour opérer dans ce mode, la PAMP, ou SPAD selon l’acronyme anglais (Single Photon Avalanche Diode), requiert un circuit d'étouffement (CE) pour, d’une part, arrêter l’avalanche pouvant causer sa destruction et, d’autre part, la réinitialiser en mode d’attente d’un nouveau photon. Le rôle de ce CE comprend également une électronique de communication vers les étages de traitement avancé de signaux. La performance temporelle optimale du CE est réalisée lorsqu’il est juxtaposé à la PAMP. Cependant, cela entraîne une réduction de la surface photosensible ; un élément crucial en imagerie. L’intégration 3D, à base d'interconnexions verticales, offr une solution élégante et performante à cette problématique par l’empilement de circuits intégrés possédant différentes fonctions (PAMP, CE et traitement avancé de signaux). Dans l’approche proposée, des circuits d’étouffement de 50 [mu]m x 50 [mu]m réalisés sur une technologie CMOS 130 nm 3D Tezzaron, contenant chacun 112 transistors, sont matricés afin de correspondre à une matrice de PAMP localisée sur une couche électronique supérieure. Chaque circuit d'étouffement possède une gigue temporelle de 7,47 ps RMS selon des simulations faites avec le logiciel Cadence. Le CE a la flexibilité d'ajuster les temps d'étouffement et de recharge pour la PAMP tout en présentant une faible consommation de puissance ( ~ 0,33 mW à 33 Mcps). La conception du PAMP nécessite de supporter des tensions supérieures aux 3,3 V de la technologie. Pour répondre à ce problème, des transistors à drain étendu (DEMOS) ont été réalisés. En raison de retards de production par les fabricants, les circuits n’ont pu être testés physiquement par des mesures. Les résultats de ce mémoire sont par conséquent basés sur des résultats de simulations avec le logiciel Cadence.
147

Conception et modélisation de détecteurs de radiation basés sur des matrices de photodiodes à avalanche monophotoniques pour la tomographie d'émission par positrons / Design and simulation of radiation detectors based on single photon avalanche diodes for positron emission tomography

Corbeil Therrien, Audrey January 2018 (has links)
La tomographie d'émission par positrons (TEP) se distingue des autres modalités d'imagerie par sa capacité à localiser et quantifier la présence de molécules marquées, appelées radiotraceurs, au sein d'un organisme. Cette capacité à mesurer l'activité biologique des différents tissus d'un sujet apporte des informations uniques et essentielles à l'étude de tumeurs cancéreuses, au fonctionnement du cerveau et de ses maladies neurodégénératives et de la pharmacodynamique de nouveaux médicaments. Depuis les tout débuts de la TEP, les scientifiques rêvent de pouvoir utiliser l'information de temps de vol des photons pour améliorer la qualité de l'image TEP. L'arrivée des photodiodes avalanche monophotoniques (PAMP), rend maintenant ce rêve possible. Ces dispositifs détectent la faible émission de lumière des scintillateurs et présentent une réponse grandement amplifiée avec une faible incertitude temporelle. Mais le potentiel des PAMP n'est pas encore entièrement exploré. Plutôt que de faire la somme des courants d'une matrice de PAMP, il est possible d'utiliser leur nature intrinsèquement binaire afin de réaliser un photodétecteur numérique capable de déterminer avec précision le temps d'arrivée de chaque photon de scintillation. Toutefois, la conception de matrices de PAMP numériques en est encore à ses débuts, et les outils de conception se font rares. Ce projet de doctorat propose un simulateur facilitant la conception de matrices de PAMP, que celles-ci soient analogiques ou numériques. Avec cet outil, l'optimisation d'une matrice de PAMP numérique basée dans une technologie Teledyne DALSA HV CMOS \SI{0,8}{\micro\metre} est proposée. En plus de guider les choix de conception de l'équipe, cette optimisation permet de mieux comprendre quels paramètres influencent les performances du détecteur. De plus, puisque le photodétecteur n'est pas l'unique acteur des performances d'un détecteur TEP, une étude sur l'impact des scintillateurs est aussi présentée. Cette étude vérifie l'amélioration apportée par l'intégration de photons prompts dans des scintillateurs LYSO. Enfin, une approche novatrice pour discriminer l'énergie des évènements TEP basée sur l'information temporelle des photons de scintillation a été développée et vérifiée à l'aide du simulateur. Bien que ce simulateur et les études réalisées dans le cadre de cette thèse soient concentrés sur des détecteurs TEP, l'utilité des PAMP et du simulateur ne se limite pas à cette application. Les matrices de PAMP sont prisées pour le développement de détecteur en physique des particules, physique nucléaire, informatique quantique, LIDAR et bien d'autres. / Abstract : Positron emission tomography (PET) stands out among other imaging modalities by its ability to locate and quantify the presence of marked molecules, called radiotracers, within an organism. The capacity to measure biological activity of various organic tissues provides unique information, essential to the study of cancerous tumors, brain functions and the pharmacodynamics of new medications. Since the very beginings of PET, scientists dreamed of using the photon's time-of-flight information to improve PET images. With the recent progress of Single Photon Avalanche Diodes (SPAD), this dream is now possible. These photodetectors detect the scintillators' low light emission and offers a greatly amplified response with only a small time uncertainty. However the potential of SPAD has not yet been entirely explored. Instead of summing the currents of a SPAD array, it is possible to use their intrinsically binary operation to build a digital photodetector, able to establish with precision the time of arrival of each scintillation photon. With this information, the time-of-flight measurements will be much more precise. Yet the design of digital SPAD arrays is in its infancy and design tools for this purpose are rare. This project proposes a simulator to aid the design of SPAD arrays, both analog and digital. With this tool, we propose an optimised design for a digital SPAD array fabricated in Teledyne Dalsa HV CMOS \SI{0.8}{\micro\metre} technology. In addition to guiding the design choices of our team, this optimisation led to a better understanding which parameters influence the performance of a PET detector. In addition, since the photodetector is not the sole actor in the performance of a PET detector, a study on the effect of scintillators is also presented. This study evaluates the improvement brought by incorporating a prompt photon emission mechanism in LYSO crystals. Finally, we describe a novel approach to energy discrimination based on the timing information of scintillation photons was developped and tested using the simulator. While this simulator and the studies presented in this thesis focus on PET detectors, SPAD are not limited to this sole application. SPAD arrays are promising for a wide variety of fields, including particle physics, high energy physics, quantum computing, LIDAR and many more.
148

Impact de la colchicine sur l'inflammation vasculaire

Gingras, Marc-Alexandre 06 1900 (has links)
Contexte : Des études récentes suggèrent que la colchicine permettrait de diminuer le risque d’événements cardiovasculaires. L’étude COLPET évaluait l’impact de la colchicine sur l’inflammation vasculaire mesurée par TEP/TDM chez des patients souffrant de MCAS stable. Méthodes : Dans cette étude randomisée à double insu de phase II, les patients étaient traités pendant 24 semaines avec 1 comprimé quotidien de colchicine 0.6 mg ou de placebo. L’inflammation vasculaire était évaluée par la captation de 18F-FDG dans l’aorte ascendante et les carotides à la TEP/TDM au début et à la fin de la thérapie. L’issue d’intérêt primaire était la variation de la moyenne du target-to-background ratio maximal des coupes d’images de l’aorte ascendante (Mean MAX TBR). Les issues d’intérêt secondaires incluaient plusieurs paramètres additionnels de TEP/TDM, ainsi que des mesures sériées de biomarqueurs inflammatoires sériques, dont la hs-CRP. Résultats : Cent-onze patients étaient randomisés dans l’étude, dont 56 au groupe placebo et 55 au groupe colchicine. La colchicine n’avait aucun impact significatif sur l’issue d’intérêt primaire (variation de la moyenne: 0.051; IC95% : -0.016 à 0.117; p=0.1346) ou sur les issues d’intérêt secondaires de TEP/TDM. Cependant, les patients traités à la colchicine présentaient une diminution de 28% de leurs niveaux de hs-CRP (p=0.0026). Conclusion : La thérapie à la colchicine pendant 24 semaines n’a eu aucun impact significatif sur la captation de 18F-FDG par l’aorte ascendante et les carotides. Cependant, une réduction de 28 % des niveaux de hs-CRP était observée chez les patients du groupe colchicine. L’étude randomisée multicentrique de phase III Colchicine Cardiovascular Outcomes Trial (COLCOT) est en cours pour évaluer les bénéfices cardiovasculaires à long terme de la colchicine (0.5 mg par jour), lorsque débutée pendant les trente jours suivant un infarctus du myocarde. / Background : Recent studies suggest that colchicine reduces cardiovascular risk. The COLPET Study evaluated the impact of colchicine on vascular inflammation, as measured by PET/CT, in patients with stable CAD. Methods: In this randomized, double-blind, placebo-controlled, phase II clinical trial, patients were treated for 24 weeks with a daily tablet of colchicine 0.6 mg or placebo. Vascular inflammation was assessed by uptake of 18F-FDG in the ascending aorta and carotid arteries on PET/CT at baseline and at the end of study drug therapy. The primary outcome was the change in the mean of maximal target-to-background ratio of the image slices of the ascending aorta (Mean MAX TBR). Secondary outcomes included various PET/CT parameters, as well as serial measures of inflammatory biomarkers, such as hs-CRP. Results: A total of 111 patients were randomized, with 56 in the placebo group and 55 in the colchicine group. Colchicine had no significant impact on the primary outcome (change in mean: 0.051; IC95% : -0.016 à 0.117; p=0.1346) or any of the PET/CT secondary outcomes. In contrast, patients treated with colchicine presented a decrease of 28% in hs-CRP levels (p=0.0026). Conclusion: Colchicine therapy for 24 weeks had no significant impact on vascular uptake of 18F-FDG in the ascending aorta or carotid arteries. However, a reduction of 28% in hs-CRP was observed in the colchicine group. The Colchicine Cardiovascular Outcomes Trial (COLCOT) is a multicenter randomized phase III trial, currently under way, evaluating the long-term cardiovascular benefits of therapy with colchicine (0.5 mg daily) when begun less than thirty days following acute myocardial infarction.
149

Développement de nouvelles molécules plateformes pour le marquage par du monoxyde de carbone : applications en imagerie par Tomographie d'Emission de Positions (TEP) et imagerie bimodale TEP/optique / Development of tags for a general lost-step isotope labeling of biomolecule-based substrates with carbon monoxide : pallado-catalized carbonylation and PET application

Cornilleau, Thomas 07 December 2016 (has links)
La Tomographie par Emission de Positrons (TEP) constitue l’une des techniques d’imagerie moléculaire les plus novatrices pour la visualisation in vivo des processus biologiques. Elle intervient comme technique de choix pour le diagnostic dans de nombreux domaines. La conception et l’élaboration de nouveaux radiotraceurs sont en perpétuel développement. Dans ce contexte une méthode d’introduction du radioisotope 11C a été développée pour le marquage de composés bioconjugées. Les conditions particulièrement douces de l’alcoxycarbonylation intramoléculaire mise au point ont permis un marquage en dernière étape de synthèse. La diversification des structures des précurseurs a également été envisagée grâce à un nouveau couplage biarylique catalysé à l’or sous conditions photorédox. Enfin la fonctionnalisation de motifs BODIPY a conduit à de premières avancées pour l’obtention de sondes bimodales innovantes. / Positron Emission Tomography (PET) is a powerful molecular-imaging technique for physiological andbiological investigations in various areas. Due to the increasing need of this technique for in vivoapplications, there is always a demand for the development of new tracers and radiolabelingstrategies. In this context an original method was developed to introduce the 11C-radioisotope for thelabeling of bioconjugated compounds. The extremely mild conditions of this intramolecular Pdcatalyzedalcoxycarbonylation allowed to label these structures in the last step of the synthesis.Diversification of the available precursors was investigated by a novel biaryl cross coupling using goldcatalisis under photoredox conditions. Finally, preliminary studies for the functionalization of BODIPYcores were realized to obtain innovative bimodal probes.
150

Etude du comportement thermique des gaz de fission dans l'UO₂ en présence de défauts d'irradiation / Thermal behavior of fission gases in UO₂ considering radiation-induced defects

Gérardin, Marie 19 December 2018 (has links)
Lors de l’irradiation en réacteur, des gaz de fission tels que le xénon et le krypton sont produits. Ces gaz diffusent dans le combustible, mais peuvent également précipiter sous forme de bulles. En outre,les réactions de fission conduisent à la formation de défauts ponctuels (lacunes ou interstitiels) et sous forme d’amas (dislocations ou cavités). L’obtention de données expérimentales sur la migration des gaz de fission en présence de défauts est nécessaire afin d’améliorer la compréhension et la modélisation du comportement du combustible sous irradiation. La démarche mise en place dans ce travail a pour objectif d’étudier la diffusion thermique des gaz et de comprendre leur interaction avec les défauts d’irradiation. Elle repose sur la réalisation d’études à effets séparés couplant des irradiations/implantations aux ions à des techniques de caractérisation fines. La Spectroscopie d’Annihilation des Positons (SAP) complétée par la Microscopie Electronique en Transmission (MET)permet de caractériser les défauts (ponctuels et/ou sous forme d’amas) générés par l’irradiation et de suivre leur évolution en température. En parallèle, la modélisation des cinétiques de relâchement des gaz rares mesurées par désorption thermique couplée à la spectrométrie de masse, permet d’obtenir les coefficients de diffusion des gaz et de mettre en lumière les phénomènes de piégeage opérants. La synthèse de ces résultats expérimentaux nous amène à identifier les mécanismes de migration des gaz et à décrire leurs interactions avec les défauts d’irradiation. / During in-reactor irradiation, fission gases such as xenon or krypton are produced. In the fuel, those gases diffuse and precipitate to form bubbles. In addition, fission reactions induce small defects(vacancies and interstitials) and larger defects (cavities and dislocations) formation. Data acquire menton fission gases migration considering radiation-induced defects is thus necessary to better understand and improve models of in-pile fuel behavior. The experimental approach developed in this work aims to study thermal diffusion of rare gases and to understand their interaction with radiation-induced defects.To do this, separated effect studies were performed coupling ion implantations/irradiations to fine characterization techniques. Positron Annihilation Spectroscopy (PAS) coupled to Transmission Electron Microscopy (TEM) observations allows for defects characterizations (vacancies and/or cavities induced by ion implantation) and for their thermal behavior study. On the other hand, gas release measurements are performed by thermal desorption spectrometry. Simulation of gas kinetic release allows to determine diffusion coefficients and to lighten trapping mechanisms. The synthesis of those various experimental results brings us to identify gas migration mechanism and to describe their interaction with radiation-induced defects.

Page generated in 0.0379 seconds