• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 124
  • 32
  • 2
  • Tagged with
  • 158
  • 69
  • 29
  • 28
  • 16
  • 15
  • 14
  • 13
  • 13
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Valideringens funktion inom barn- och ungdomspsykiatrin

Mellgren, Malin, Annica, Holmberg January 2017 (has links)
The aim of this study was to examine how therapists reflect about the importance of validation in their clinical work with children and adolescents at Barn- och Ungdomspsykiatrin (BUP). The study is qualitative and had a design with three focus group interviews with a total of thirteen respondents. The interview guide was half structured and every session lasted for two hours. The results show that all the respondents highlight the value of constant use of validation within their therapy sessions. They picture that validation is an important key to reach alliance with the patient. It is clear that the therapists use different validation strategies when they meet children compared with adults. The researchers make new findings that have not been found in previous science, empirics that do not match our theoretical basis. These findings contents how the respondents through play, a more explicit body language, more physical contact, an affirmative attitude and creative practice matches and adapts their validation strategies when they meet children in the therapy room. They describe a distinct difference in their way to validate children. Finally, the results show that validation reinforces the therapeutic relationship between and is a necessary factor to make the patient safe and able to participate in a process of treatment.
32

Arbetsförmedlingens studie- och yrkesvägledning av nyanlända vuxna : En kvalitativ studie om vägledning av nyanlända vuxna under deras etableringstid i två svenska kommuner

Markova, Daria, Nätt, Tina January 2018 (has links)
Syftet med vår studie är att få mer kunskap om och förståelse för Arbetsförmedlingens arbete med studie- och yrkesvägledning för nyanlända vuxna i två svenska kommuner under etableringstiden. Detta syfte leder oss fram till våra frågeställningar som följer. Hur arbetar Arbetsförmedlingen i respektive kommun med studie- och yrkesvägledning av nyanlända vuxna? Vilket stöd/kompetensutveckling anser vägledarna sig behöva för att lyckas med sitt uppdrag? Vilka är framgångsfaktorerna och vilka är motgångarna stöter de nyanlända och vägledarna på? För att få svar på vårt syfte har vi använt oss av kvalitativa intervjuer. Vi har intervjuat en chef på vardera Arbetsförmedling och två studie- och yrkesvägledare i varje kommun. Resultatet visar att Arbetsförmedlingen och kommunens Vuxenutbildning har ett samarbete för att genomföra etableringsuppdraget, men detta samarbete behöver utvecklas och ökas. Det framkommer också behov av kompetensutveckling, samt behov av kunskaps- och erfarenhetsutbyte mellan dessa aktörer. Studie- och yrkesvägledning, anser de intervjuade, har en väldigt stor betydelse för nyanlända vuxna, särskilt under deras etableringstid. För vidare forskning kan det vara intressant att undersöka nyanländas syn på studie- och yrkesvägledning, valideringsfrågor och dess betydelse för nyanlända att snabbt etableras.
33

Automatiserad kunskapsvalidering

Sköld, Lars January 2008 (has links)
Denna uppsats granskar möjligheter att använda datorstöd för automatisk rättning av olika typer av utvärdering. Olika teorier jämförs med varandra för att utvärdera deras styrkor och svagheter och för att se vilka begränsningar som finns idag. Tanken är att se möjligheterna med dessa system och vad som är möjligt att använda och när det är ekonomiskt försvarbart att använda automatisk utvärdering istället för manuell rättning.
34

Metoder för interaktiv systematisk validering av personal inom äldreomsorgen

Bodenhem, Peter, Eckmar, Fredrik January 2006 (has links)
OFF-E är ett pågående projekt som drivs av Sandvikens kommun. Det är ett projekt som planerar att utveckla en ny form av validering inom kompetensområdet vård och omsorg. Detta sker med utgångspunkt ifrån en befintlig plattform utvecklad av Mapaz MZ. Valideringen sker i dagsläget manuellt. De olika skeden i den aktuella valideringen är kartläggning, självskattning, individuell arbetsplan, teoretisk och praktisk validering, bedömning av delmål och komplettering av utbildningsinsatser. Detta resulterar i en anpassad studieplan samt redan godkända betyg i den specifika kursen. Med nya tekniska förutsättningar fanns anledning att ompröva denna metod. Genom att ett nytt verktyg utvecklas och utformas i tre delar: Teoretisk validering och utbildning, praktisk validering och utbildning (Scenarion), praktisk validering och utbildning i ett försöksrum. Syftet med vår uppsats är att utveckla delen som berör praktisk validering och utbildning via scenarion och cases. Vi har bestämt oss för att försöka skapa olika metoder för detta, för att sedan bestämma vilken av dessa som är mest lämpad ur ett användarvänligt perspektiv. Metoden vi tar fram kommer kunna tillämpas i framtida utvecklingsprojekt.
35

Validering av Social Competence Scale för observatörer i ett stickprov från den svenska förskolan

Kvamme, Ylva January 2014 (has links)
Likvärdigheten i den svenska skolan har på senare år försämrats. Social och emotionell kompetens har visat sig ha stor betydelse för skolframgång, psykisk hälsa och förekomst av problembeteenden och interventioner som stärker dessa kan vara ett sätt att åtgärda skolans problem. För utvärdering av sådana interventioner behövs validerade mätinstrument. Denna studies syfte var att undersöka validiteten hos Social Competence Scale för observatörer (SCO). Skalan används vid en standardiserad leksituation för att skatta barns sociala och emotionella kompetens. En explorativ faktoranalys genomfördes på SCO, samt korrelationer med två kriteriemått, utifrån hypotesen att finna positiva korrelationer. Dessa två var Social Competence Scale för lärare, en lärarenkät som ligger till grund för SCO, och Assessment of Childrens Emotions, en uppgift där barn ska identifiera känslor utifrån ansiktsbilder. I likhet med tidigare analyser av instrumentet fann studien en faktorstruktur med en faktor. Inga signifikanta korrelationer mellan SCO och de två kriteriemåtten erhölls. Skalan behöver studeras vidare för validering. Bortfall och förändringar i skalans administration under datainsamlingen gör att resultaten bör tolkas försiktigt.
36

Validering av S-Zink på Beckman Coulter AU680 : samt hållbarhetsstudie och provrörsstudie

Shek, Jennifer January 2018 (has links)
Zinc is an essential mineral that has many biological and structural functions in the cells. In Sweden, zinc analysis is performed with different methods and test tubes. The recommended value of zinc is between 11-17 µmol/L together with normal albumin rate. The aim of this study was to validate the colorimetric method for analysis of S-Zinc by comparing the results from two Beckman Coulter AU680 instruments for the insertion of these at the Department of Clinical Chemistry and Transfusion Medicine, Country council of Kalmar. Precision study, correlation study and comparison study was made between the kinds of test tubes BD Vacutainer® Blood Collection Tubes, one consisting of a gel separator, one without contents and the last type contained silica particles. A correlation study was made by comparing patient samples obtained from the department of clinical chemistry, Country council of Jönköping. In the comparison study, serum probes were provided by the staff at the Department of Clinical Chemistry, Kalmar. The blood samples were taken in two kinds of blood collection tubes without contents (one containing silica particles) and one blood collection tubes with gel. The serum tests were analyzed for 4 days and the test results were studied and compared between the collection types. The conclusion of the study was that S-Zink on the Beckman Coulter AU680 instrument with reagents from Sentinel Diagnostic was acceptable. Both Beckman Coulter AU680 instruments provided equivalent results. The correlation between Beckman Coulter AU680 and Thermo Konelab Prime 30i was acceptable. The correlation coefficient showed a high correlation rate between the different methods (r=0, 93). The sustainability of the serum samples, that was poured in new tubes and stored in 2-8°C for 4 days, was good. The study showed distinct differences when analyzing different blood collection tubes, were the collection tube containing gel showed a higher zinc rate. When insertion of the new method, S-Zink, it is recommended that blood collection tubes without contents are used, because of the risk of zinc contamination from collection tubes with gel and plastic stoppers.
37

Analytisk bestämning av fruktos, glukos och sackaros i dryck / Analytical Measurement of Fructose, Glucose and Sucrose in Beverages

Holroyd, Josefine January 2015 (has links)
Denna studie utfördes på Systembolagets laboratorium i Jordbro, där ett flertal analyser utförs på alkoholhaltiga och alkoholfria drycker i Systembolagets sortiment. Studien syftade till att utforma en förbättrad metod vid bestämning av koncentrationen glukos, fruktos och sackaros i drycker med en alkoholhalt under 15 vol% och med en sockerhalt under 5 g/l. Den befintliga metod som användes idag behövde utvecklas för att kunna ge en högre mätsäkerhet. För att bestämma halten av glukos, fruktos och sackaros används ett spektrofotometriskt instrument som använder sig av enzymatiska metoder för att mäta olika koncentrationer, i det här fallet glukos, fruktos och sackaros. Tre olika kalibreringskurvor skapades från en standardlösning med en koncentration på 0,5 g/l av vardera sockerart, för att innefatta intervallet 0-5 g/l. En flerpunktskalibrerings med fem punkter gjordes då det blir ett säkrare resultat än med en enpunktskalibrering som tidigare använts. När kalibreringskurvorna var utformade validerades metoden, vilket måste göras innan den kan godkännas. Metodvalidering innebär att vissa tester genomförs för att bevisa att metoden faktiskt gör det den ska göra. De valideringsparametrar som prövades var repeterbarheten, den mellanliggande precisionen, detektionsgränsen, rapportgränsen, riktigheten och mätosäkerheten. För beräkning av mätosäkerhet användes HPLC som referensmetod. Ett kontrollkort utformades för respektive sockerart genom att ett kontrollprov tillverkades syntetiskt med en koncentration på 1 g/l av de olika sockerarterna. Tjugo stycken prover togs från kontrollprovet där samtliga analyserades mot en ny framtagen kalibreringskurva. Resultaten sammanställdes i ett kontrollkort där varningsgräns och aktionsgräns markerades ut. Kontrollkorten kommer att användas som ett referensprov tillsammans med prover varje gång analyser görs. Resultatet för kontrollprovet visar om något i körningen gått snett. Om resultaten inte passar in i kontrollkortet är det med stor sannolikhet att det gått snett även för proverna. Kontrollkort är inte en del av valideringen men något som behövs för att laboratoriet ska kunna ackreditera metoden. Valideringen visade att metoden som utformades för ändamålet var bättre än den ursprungliga metoden och den nya metoden kunde tas i bruk. / This study was carried out in the laboratory at Systembolaget Company in Jordbro. The laboratory performs many analyses on alcoholic and non-alcoholic beverages, which can be found in the selection at Systembolaget. The purpose of the study was to form an improved method for determination of the concentration of glucose, fructose and sucrose in beverages with an alcohol content below 15 % and a sugar content lower than 5 g/l. The current method needed to be improved to give a higher measurement certainty. To determine the content of glucose, fructose and sucrose a spectrophotometric instrument for enzymatic methods was used. Three different calibration curves where formed from a standard solution with a concentration at 0,5 g/l of each sugar, to include the interval of 0-5 g/l. Calibrations curves with five points where formed to give a safer result than with only one point. After the calibration curves were formed, the method was validated. A method needs to be validated before it can get approved. Validation means that certain tests must be done to prove the method is actually doing what it is supposed to do. The validation parameters that were chosen were the instrument precision, the intermediate precision, the detection limit, the reporting limit, the accuracy and the measurement uncertainty. For the measurement uncertainty the results were compared to results which had been analysed with a HPLC. A control chart was formed for each of the sugars. A control sample was synthetically made with a concentration of 1 g/l of each of the sugars. Twenty samples were taken from the control sample where each of them were analysed against a newly done calibration curve. The results were put together in a control chart where warning limits and action limits were marked. The control chart will tell if analyses in the future go wrong. A sample from the control sample will be analysed together with future analyses. If the results from the control samples doesn’t get approved by the control chart there is a very big chance that the results for the other samples are also bad. Control charts are not a part of the validation but are required if the laboratory wants the method to get accredited. The validation of the method showed that the new method was better than the old one.
38

Validering av metod för analys av mineraloljor i vatten med infraröd-spektrofotometri : Går det att uppnå en god detektionsnivå och minimera hälsoriskerna för laboratoriepersonal vid användning av tetrakloretylen i den validerade metoden?

Lindkvist, Malin January 2018 (has links)
Bakgrund: Tetrakloretylen (TTCE) har flera humantoxikologiska och ekotoxikologiskaegenskaper, bla ökad risk för flera olika typer av cancer samt bildande av marknära ozon som bidrar till växthuseffekten. Ämnet används ofta som lösningsmedel vid analys av mineraloljor i vatten med hjälp av IR-spektrofotometri. TTCE är svårt att ersätta med andra lösningsmedel på grund av dess positiva egenskaper vid denna typ av analys. Bland annat ger TTCE inget eller ytterst lite utslag på FTIR spektrat där avläsning av alifatiska och aromatiska kolväten sker. Syfte: Syftet med rapporten är att validera ett nytt instrument samt att minimera hälsoriskerna för berörd laboratoriepersonal som arbetar med tetrakloretylen. Metod: I samband med valideringen av metoden, analys av mineraloljor i vatten medinfraröd spektrofotometri, har en riskbedömning i form av en checklista genomförtstillsammans med bland annat skyddsombud för att säkerställa en säker arbetsmiljö. Resultat: Instrumentets och metodens linjäritet klarade kravet på R2>0,995. Totalt extraherbara alifatiska och aromatiska kolväten i halterna 1,0 samt 15 mg/l klarade mätosäkerheten på 15%. Data över riktigheten behöver kompleteras innan ett rättvist resultat kan erhållas. Slutsats: Valideringen av metoden LidMiljö0A.01.19 version 10, mineralolja i vatten med infraröd spektrofotometri, visar att den tidigare rapporteringsgränsen på 1,0 mg/l kommer att kvarstå. Hälsoriskerna för personalen som arbetar med analysmetoden, kan enligt denna studie minimeras till en godtagbar nivå som innebär att laboranten utsätts för minimal risk. / Background: Tetrachlorethylene (TTCE) has several human- and ecotoxicological properties, including increased risk for several types of cancer, as well as formation of ground-level ozone that contributes to the greenhouse effect. The substance is often used as solvent for the analysis of mineral oils in water by means of IR spectrophotometry. TTCE is difficult to replace with other solvents due to its positive properties in this type of analysis. Among other things, TTCE gives no or very little impact on the FTIR spectra where reading of aliphatic and aromatic hydrocarbons occurs. Purpose: The purpose of this report is to validate a new instrument and to minimize the health risks for the laboratory staff using the method. Method: In connection with validation of the method, analysis of mineral oils in water with infrared-spectrophotometry, a risk assessment in the form of a checklist has been implemented together with personnel which has an increased resonsibility of the working enviroment, to ensure a safety of the workplace. Results: The linearity of the instrument and the method met the requirement of R2> 0,995. Total extractable aliphatic and aromatic hydrocarbons at levels of 1,0 and 15 mg/l achieved uncertainty of the measurement by 15%. The data regarding correctness needs to be further expanded to obtain a relaiable result.3 Conclusion: The validation of the method LidMiljö0A.01.19 version 10, mineral oil in water with infrared-spectrophotometry, shows that the previous limit of 1,0 mg/l will remain. Health risks for the personnel involved in the analysis method can, according to this study, be minimized to an acceptable level.
39

Metodutveckling och påbörjan till validering med HPLC för formalin / Method development and beginning of a validation with HPLC for formalin

Johansson, Frida, Pettersson, Hanne January 2022 (has links)
Formalin är ett ämne som finns naturligt både i naturen och i människokroppen. Formalin syntetiseras i dagsläget industriellt bland annat på grund utav sina goda egenskaper för desinficering. Det används till exempel i autoklaver på sjukhus för sterilisering av verktyg. Formalin är ett ämne som klassas som cancerogent och som i större mängder är giftigt. Därmed är det viktigt att observera och mäta upp de mängder formalin som blir till utsläpp i naturen, eller som återfinns på sjukhusverktyg. Företaget Ak Lab AB, som är ett ackrediterat laboratorium, genomför idag analyser av filter som funnits i formalinautoklaver för att kvantifiera dessa värden. Den nuvarande metoden för detta är manuell och använder sig av en spektrofotometer. Det önskas att automatisera delar av processen, samt att minska ner på beredningstiden för proverna. I detta examensarbete har en litteraturstudie med avseende på formalin, HPLC och lämplig metod utförts. Därefter har en metod modifierats och sedan har valideringsarbetet påbörjats. Denna metod är baserad på den amerikanska metoden EPA-8315a. Prover har analyserats medd en nuvarande spektrofotometermetoden men även med den nya framtagna HPLC-metoden för att jämföra metoderna, samt för att fastställa om korrekta värden uppmäts. Framkommande av arbetet är att en metod för att påvisa formalin har utvecklats. Det accepterade koncentrationsintervallet för formalinanalys är fastställt av arbetet att vara från 5mg/l till 150 mg/l. I jämförelse med nuvarande spektrofotometermetoden skilde sig kvantifigeringsmängden av formalin. En valideringsprocess för metoden har påbörjats och en arbetsbeskrivning har framtagits. Metoden kan påvisa förekomsten av formalin, men ytterligare beräkningsarbete och optimering behöver göras innan metoden kan implementeras. Förslag för förbättring samt diskussion kring arbetets svagheter respektive styrkor har genomförts. / Formalin is a substance that is found naturally both in nature and in the human body. Formalin is currently synthesized industrially due to its good disinfectant properties, among other things. It is used, for example, in autoclaves in hospitals for sterilizing tools. Formalin is a substance that is classified as carcinogenic and in large quantities is toxic. Thus, it is important to observe and measure the amounts of formalin that are released into nature, or that are found on hospital tools. The company Ak Lab AB, which is an accredited laboratory, is currently carrying out analyzes of filters that have been in formalin autoclaves to quantify these values. The current method  for this is manual and uses a spectrophotometer. The desire is to automate parts of the process, as well as to reduce the preparation time for the samples. In this thesis, a literature study with regards to formalin, HPLC and a suitable method has been performed. Subsequently, a method has been modified and then the validation work has begun. This method is based on the American method EPA-8315a. Samples have been analyzed with the current spectrofotometer method but also with the newly developed HPLC method to compare the methods, and to determine whether correct values are measured. The conclusion of the work is that a method for demonstrating the presence of formalin has been developed. The accepted concentration range for formalin analysis is determined by the work to be from 5 mg/l to 150 mg/l. In comparison to the current spectrophotometer method, the quantification amount of formalin differed. A validation process for the method has begun and practical instructions have been developed. The method can detect the presence of formalin, but further calculation work and optimization need to be done before the method can be implemented. Suggestions for improvement and discussion about the work’s weaknesses and strengths have been implemented.
40

Utvinning av data ur mobiltelefoner : En valideringsstudie av forensiska verktyg

Andersson, Roland January 2016 (has links)
Den vetenskapliga aspekten i de flesta forensiska discipliner är välgrundad och prövad under ett långt tidsperspektiv. Det ökande användandet av digital teknik har gjort att en ny forensisk disciplin har vuxit fram och den vetenskapliga grunden i detta nya forensiska område är i många avseenden fortfarande outforskat. Inom det svenskarättsväsendet krävs att de forensiska metoder som används inom en brottsutredning ska vara kvalitetssäkrade och i största mån vara ackrediterade av ettackrediteringsorgan. Det finns idag få relevanta studier kring validering av forensiska metoder som hanterar småskaliga enheter som smarta mobiler. I denna rapport analyseras de metoder som används för att utvinna data från mobiltelefon och hur dessa metoder kan anses vara forensiskt korrekta. Rapporten presenterar ett nytt ramverk för att validera de metoder som används av ett forensisk verktyg. Ramverket är kvalitetssäkrat genom att utgå ifrån tidigare vetenskaplig studier och är praktiskt testad i laboratoriemiljö. Ramverket ska kunna användas direkt inom en forensisk verksamhet som kräver validering. / The scientific aspect in most forensic disciplines is well founded and examined under a long-term perspective. The increasing use of digital technology has enabled a new forensic discipline and the scientific basis of the digital forensic field is in many respects still unexplored. The Swedish legal system requires that the forensic methods used in a criminal investigation should be quality assured and in the largest extent be accredited by an accreditation body. There are few relevant studies on the validation of forensic methods that handle small scale devices such as smartphones. This report analyzes the methods used to extract data from a mobile phone and how these methods can be considered forensically sound. The report presents a new framework for validating the methods used by a forensic tool. The framework is quality assured by referring to previous scientific studies and practically tested in a laboratory environment. The framework can be used directly in a forensic organization that requires validation.

Page generated in 0.3587 seconds