• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 105
  • 3
  • Tagged with
  • 108
  • 58
  • 56
  • 39
  • 24
  • 24
  • 23
  • 23
  • 21
  • 21
  • 21
  • 19
  • 17
  • 14
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Energikartläggning och energieffektivisering av flerbostadshus : Utredning av möjliga energibesparande åtgärdsplaner i området Oxhagen, Örebro.

Gunnarsson, John, Wallberg, Ida January 2022 (has links)
The purpose of this report is to investigate how Örebrobostäder (ÖBO) can decrease their energy use in the residential area of Oxhagen. Oxhagen is as mentioned a residential area located west from Örebro center and have about 690 apartments in different sizes. ÖBO needs to do this survey because they obey from the law of energy mapping in large companies, this law is produced from the EU directive, energy efficiency directive with its purpose to reduce the energy using in the country so the imported energy decreases. Energy statistics have been handed from ÖBO, this energy data has been analyzed and the data have been put in respective calculations, using Excel. Also, a model of a real estate has been made in the simulation program IDA ICE, in this simulation program energy calculations are made. There has also been a technical inspection of the reference real estate. The result shows that the biggest decrease in energy will happen with a decrease in the heating of the building. It also shows that a change of windows can reduce energy use significantly. Therefor the conclusion is that a combination of heat decrease, and window change can make an enormous difference in energy using for the reference real estate and the combination can also apply on other real estate in the area Oxhagen.
102

Improving energy performance within the framework of the Energy Efficiency Directive / Förbättra energiprestanda inom ramen för Energieffektiviseringsdirektivet

Wilhelmsson, Jessica, Åkerblom, Signe January 2015 (has links)
Det är nödvändigt för stora företag att förstå och kunna anpassa sig till den industriella omvandling mot ett ökat fokus på energieffektivitet som sker idag. Energieffektiviseringsdirektivet som Europeiska Unionen har utfärdat har ökat fokus på att arbeta med energieffektivitet i stora företag. Vidare har den svenska regeringen infört lagen om energikartläggning i stora företag som är baserad på Energieffektiviseringsdirektivet. Dessa lagstadgade krav uppmuntrar företag att utveckla ett ledningssystem som ställer krav på genomförande av energikartläggningar samt föreslå kostnadseffektiva åtgärder. Energieffektivitet är redan en riktigdel i många företags miljöarbete dock krävs ett mer Utvecklat och systematiskt arbetssätt än det många företag redan har för att uppnå kraven i Energieffektiviseringsdirektivet och den svenska lagen. Företaget som har undersökts i denna studie är ett världsledande teknikföretag med mer än 9000 anställda i Sverige. För närvarande har de energi som en signifikant aspekt i sitt miljöarbete i enlighet med den internationella standarden för miljöledningssystem ISO14001dag utvecklar de även sitt energiarbete genom att utföra energikartläggningar för att uppfylla den nya lagstiftningen. Detta ger en mer detaljerad insikt över energianvändningen och möjliga förbättringar som kan göras, men för att säkerställa ständiga förbättringar över en längre tidsperiod krävs ytterligare åtgärder.  I den här studien har det undersökts vilka åtgärder som ett stort företag måste införa för att öka energiprestandan och följa lagstiftningen. Genom en litteraturstudie som fokuserade på ledningssystem i kombination med intervjuer på det undersöka företaget, en kompletterande studie av två företag som omfattas av direktivet samt tre expertintervjuer identifierades fem nyckelfaktorer. Dessa faktorer är högsta ledningens engagemang, medvetenhet, mål, mätningar och utvärdering. En modell för att strukturera faktorerna utvecklades sedan. Vidare presenterades konkreta förslag på hur dessa faktorer ska implementeras. Genom att öka fokus på dessa nyckelfaktorer och implementera föreslagna åtgärder kommer företag öka sin energiprestanda och medvetenhet i organisationen om hur olika handlingar påverkar företagets energiprestanda. / It is necessary for large companies to understand and be able to adapt to the industrial Transformation towards an increasing focus on energy efficiency, which takes place today. The Energy Efficiency Directive (EED)issued by the European Union has enlarged the focus on working with energy efficiency within large companies. Further, the Swedish government has introduced the law about energy auditing in large companies, which is based on the EED. These regulations encourage companies to develop a management system that includes requirements on conducting energy audits and propose cost Deffective measures. Energy efficiency is already an important aspect within many companies environmental work, however a more developed and systematic approach to energy efficiency than most companies already have is needed in order to fulfill the legal requirements. The Company investigated in this study is one the worlds leading technology companies with more than 9000  employees in Sweden. Currently, they have energy as a significant aspect in their environmental work according to the international management system standard ISO 14001. Today they are also developing their energy work by conducting energy audits in order to comply with the new legislation. This gives a mor detailed view of the energy use and potential improvements that can be done, but in order to ensure continual improvements over a long period of time further measures are needed. Within this study it was investigated what measures a large company needs to implement in order to increase their energy performance and comply with the legislation. By a literature review focusing on management systems as well as interviews within the Company, a complementary study with two companies covered by the EED and three expert  interviews, five key factors were identified. These factors are, top management commitment, awareness, goals, measurements and evaluation. A model was then developed aligning these factors. Further, concrete proposals for action to manage these factors were presented. By!increasing focus on these key factors and implement proposed measures companies will increase their energy performance and also make the organization aware of how actions affect a company’s energy performance
103

Uppföljning av en energikartläggning : Med fokus på ekologiska, ekonomiska och sociala aspekter / Follow-up of an energy survey : with focus on ecological, economic and social aspects

Ahmed, Chera January 2022 (has links)
Denna studie behandlar en energikartläggning och hur framtida energikartläggningar kan utvecklas för att uppnå hållbar utveckling utifrån samtliga hållbarhetsaspekter. Studien består av analyser och fördjupningar i olika frågor som behandlar hållbar utveckling. Syftet med studien är att analysera och följa upp tidigare utförda energiåtgärder samt följa upp fortsättningen på energikartläggningen genom att analysera resultatet utifrån miljömässiga, ekonomiska och sociala aspekter. Vid en energikartläggning är det ekonomiska och ekologiska aspekter som tas i beaktning samtidigt som sociala aspekter vanligtvis exkluderas. Denna studie skall bidra till möjligheten att inkludera sociala aspekter vid energieffektivisering i en energikartläggning för att kunna bidra till den hållbara utvecklingen i sin helhet. För att kunna uppnå syftet med studien har författaren använt sig av olika kvalitativa metoder som intervju, platsbesök och observation. Genom kvalitativa metoder och tidigare dokumenterade uppföljningar skapas en tolkning över aktuell situation och tidigare utförda åtgärdsförslag. Utöver det har databasen Primo använts samt olika vetenskapliga artiklar och rapporter studerats. Resultatet består av en analys av energikartläggningen och visar hur den kan utvecklas genom att även inkludera sociala åtgärdsförslag. Genom att inkludera samtliga hållbarhetsaspekter erhålles ytterligare ekonomiska besparingar i jämförelse med att bara beakta miljömässiga och ekonomiska aspekter. Sociala åtgärdsförslag bidrar till större engagemang från de boende. Detta resulterar i en ekonomisk besparing i form av ökad miljökompetens och konsekvenstänk gällande energiförbrukning. / This study addresses an energy survey and how future energy surveys can develop to achieve sustainable development based on all sustainability aspects. The study consists of analyzes and in-depth questions on various issues about sustainable development. The purpose of the study is to analyze and follow up on previously carried out energy measures and follow up the continuation by analyzing the results based on environmental, economic and social aspects. In an energy survey, the economic and ecological aspects are taken into account, social aspects are usually excluded. This study will contribute to the possibility of including social aspects in an energy survey as well in order to contribute to the sustainable development as a whole. In order to achieve the purpose of the study, the author has used various qualitative methods such as interviewing, site visits and observation. Qualitative methods and previously documented follow-ups of the energy survey, creates an interpretation of the current situation and previously implemented action propsals. In addition, the Primo database has been used and various scientific articles/reports have been studied. The results consists of an analysis of the energy survey and shows how it can develop by including social aspects. By including all sustainability aspects, additional financial savings are obtained compared to only environmental and economic considerations. Social action proposals contribute to greater involvement of the residents. This results in an economic saving in form of increased environmental competence and consequent thinking on energy consumption.
104

Energiaktiviteter i kunskapshus : En detaljerad kartläggning / Energy activities in educational buildings

Vaghult, Sara, Adolfsson, Anna January 2019 (has links)
Denna studie innefattar en så kallad aktivitetsbaserad energikartläggning som på en detaljerad nivå kartlägger relationen mellan aktiviteter i en skola med användningen av el. Metoden som används baseras på en traditionell metod för energikartläggning men elanvändning kartläggs minut för minut över en hel skolvecka vilket är ovanligt vid energikartläggningar. Data har samlats in för Berzeliusskolan i Linköping under vecka nio och analyserats i förhållande till andra veckor, skolor och nationella mål. Berzeliusskolan är en grund- och gymnasieskola med 1600 elever. Resultatet från studien kan användas för att bättre förutse energianvändning i nya skollokaler och för att prioritera bland möjliga energibesparande åtgärder. Resultatet från kartläggningen visar att de energiaktiviteter som orsakar störst energibehov är fastighetsdrift (33 %), skollunch (25 %) samt rekreation (15 %). Rekreation är definierat som aktiviteter utan direkt koppling till undervisning eller skollunch och innefattar bland annat uppehållsrum, korridorer och personalkök. Alltså är undervisning inte det som påverkar energianvändningen i en skola i första hand.   De viktigaste lärdomarna för genomförande av liknande energikartläggningar är att fokus inte bör ligga på elever och pedagoger utan på byggnaden och skolköket i stort. Eftersom energikartläggningen enbart täcker en skolvecka bör liknande studier genomföras för kunskapshus under skollov för att komplettera denna studie. / This master thesis includes an activity based energy audit in a combined elementary and upper secondary school in Linköping. The audit was conducted at a detailed level to show the connection between activities in schools and energy performance. The focus has largely been on electricity use and the overall method is based on traditional energy audit. The method however is distinct from traditional methods by the fact that electricity is shown minute by minute over a full school week. The results from the study can be used to better foresee energy use in new or remodeled schools. Also, the results is a valuable basis for prioritizing among energy conservation measures connected to similar schools and buildings. The main results from the energy audit shows that building services (33 %), school lunch (25 %) and recreational activities (15 %) are the most important energy activities. It is also found that education itself only contributes to a limited extent. The most important factors in conducting such an activity based energy audit is that focus shouldn’t been on students and faculty but instead on the indoor climate systems and school kitchen. To continue this research, similar audits should be conducted in more schools and during school breaks.
105

Energy efficiency in a renovated modern office with activity-based work style

Olausson, Jesper January 2019 (has links)
During renovation Ljusåret 2 was converted to a modern office with an activity based work style (ABW) with a Demand Controlled Volume (DCV) ventilation system connected to a closed-loop duct. Cooling is provided through air handling units and active water based beams, the underfloor heating system was kept. Written instruction and specification have been studied for the two different control systems Schneider EcoStructure and Lindinspect. Both control systems have been analyzed according to time schedule, set-point and process value by using different functions in software. To be able to perform a energy audit and look at indoor climate for Ljusåret 2 there have been studies according to underfloor heating, constructions of ventilation system, diversity factor for DCV, closed-loop-ducts, heat losses from ducts, cooling demand and energy certification. According to this audit, energy performance is calculated to 89.1 kWh/m2 according to building energy, activity energy is not audited or calculated. During design phase, an energy calculation was made by an energy consultant with the result of 81.3 kWh/m2. The estimated performance is a 9.6 % increase. This building is designed for Miljöbyggnad certification of level silver and should be ≤ 109 kWh/m2,year. According to audit and calculation for energy performance this level is possible to keep. The estimated energy performance have been calculated with only 4 month of statistics from January until April 2019 because Ljusåret 2 have just been renovated. District heating has been estimated through the energy signature by data from energy meter. Electrical components for the building have been measured and energy usage calculated. Energy produced by compression chiller have been estimated with calculated performance from design phase and adding heat transfer between rooms and supply ducts. Energy between rooms and supply ducts were not included in energy calculation during the design phase. According to the control system for the DCV system there have been some issues with high temperature in supply ducts even when they are supplied with 15 ºC from air- handling unit. There have been measurement to the ventilation system 5701-5704 that is connected to a close-loop duct with a result of temperatures between 15.2 ºC up to 21.4 ºC and the velocity has varied between 0.05-2.1 m/s in different measurement spots. This is an increase of 6.4 ºC. A heat transfer calculation have been made in Paroc Calculus to estimate heat transfer between room and supply ducts. The results of this calculation indicates the same level of temperature increases as when the system was measured. With no thermal insulation cooling capacity is lost to half after less than 5 m with a velocity of 0.2 m/s, after 15 m with a velocity of 1 m/s and 30 m with a velocity of 2 m/s . This should be compared with supply duct with 20 mm of thermal insulation that has lost its cooling capacity after less than 13 m with a velocity of 0.2 m/s, after 63 m with a velocity of 1 m/s and is increase with 4 ºC after 100 m with a velocity of 2 m/s. Using closed-loop ducts with velocity below 2.0 m/s and without thermal insulation combined with under tempered supply air is not a good combination. Even short length with low velocity and lack of thermal insulation is devastating because of heat transfer according to logarithmical temperature difference between room and supply ducts. A closed-loop duct is often designed as a pressure chamber and recommended when using DCV and/or VAV ventilation to avoid problems with noise and to be able to reduce the need of dampers. Problems with temperature increasing according to velocity in ducts must be taken in consideration. For Ljusåret 2 this will affect district heating usage where ducts are placed because underfloor heating must compensate heat transfer. Chilled water must be provided an extra time for rooms with both DCV and chilled beams and rooms with only DCV is less comfortable which they could been with a correct installation.
106

Zero CO2 factory : Energikartläggning av industrier och ett exempel på hur noll utsläpp nås / Zero CO2 factory : An energy audit of industries and an example on how to reach zero emissions

Wannemo, John January 2019 (has links)
Industrin står för 32% av den globala energianvändningen och majoriteten av industrins utsläpp sker vid förbränning av fossila bränslen för värmeanvändning. Hälften av industrins värmeanvändning uppskattas vara i temperaturer upp till 400 °C vilket är lämpligt för värme från solfångare.Klädesindustrin står för 10% av de globala växthusgasutsläppen och majoriteten av de utsläppen sker vid textilproduktion och flera av textilindustrins processer är i temperaturintervall som kan använda värme från solfångare likt Absolicons T160.Data från energianvändning hos textilfabriker har samlats in och beräkningar på energianvändning och utsläpp har gjorts för erhållna data. Solfångarnas energiberäkningar har gjorts med hjälp av simuleringar från Absolicon applikation Field Simulator. En 3-stegs plan gjordes för 2 stora textilfabriker i Indien som visar hur de skulle kunna eliminera sina utsläpp från energianvändning.Kartläggningen visar att textilindustrin till stor del använder fossila bränslen och de 5 största textilfabrikerna i denna rapport visar en energifördelning mellan värme och el på 85% respektive 15%. Utsläppen per producerad massa varor i kg för de 5 fabrikerna uppskattas vara i snitt 6,1 kgCO2e vilket motsvarar en förbränning av 2,1 kg brunkol.De två stora textilfabriker i Indien samlade utsläpp från energianvändning redovisas vara 686 ktCO2e. Värmeanvändningen i fabrikerna sänks i 3-stegsplanen med 17% och fossila bränslen ersätts med värme från solfångare och biomassa. För att täcka 68% av det nya värmebehovet med värme från solfångare så behövs det solfångarfält med en termisk effekt på cirka 400 MW och en yta på cirka 1,3 km2. De resterande 32% av värmebehovet ska komma från förbränning av cirka 100 000 ton biomassa per år.Industrin har möjlighet att sänka stora delar av sina utsläpp genom att ersätta fossila bränslen i värmeanvändningen med till exempel värme från solfångare och biomassa. För att täcka stora delar av värmeanvändningen med solfångarfält behövs lediga ytor runt om och på fabrikerna. Fossila bränslen har i dagsläget ett lågt pris i förhållande till dess utsläpp och tillämpning av globala utsläppsrätter eller skatter bör appliceras för att påskynda omställningen till utsläppsfri energi och lägre utsläpp. / The industry sector accounts for 32% of the global energy usage where the majority of the energy is being used as heat. Most of the heat is generated by burning fossil fuels which leads to heat use being the largest source of emissions in the sector. About half of energy used as in the industries are in temperatures up to 400 °C which is suitable for heat provided by solar collectors.The apparel industry accounts for 10% of the global carbon emissions and multiple of the industry processes used in textile production are in temperature ranges reachable with solar collectors such as Absolicons T160.Energy data was collected from textile factories and calculations of energy usage and emissions was made. The calculations for solar collectors was made with Absolicons web application Field Simulator. A 3-step plan was created to demonstrate how two textile factories in India could reach zero CO2 emissions.The analysis shows that the textile industry’s majority of energy is being used from fossil fuels to generate heat where the 5 largest factories in this report average energy is 85% as heat and 15% as electricity. The emissions per produced mass of goods in kg is an average of 6,1 kgCO2e at these 5 factories which is comparable to burning 2,1 kg of black coal.The two large textile factories combined emissions from energy usage is reported to be 686 ktCO2e. In the 3-step plan the heat usage is reduced by 17% and heat from fossil fuels are replaced by heat from solar collectors and biomass. To cover 68% of the new energy demand it would require solar fields with a total thermal capacity of about 400 MW and an area of 1,3 km2. The remaining 32% of heat demand would be covered by burning 100 000 tonne of biomass per year.The conclusion is that he industry sector has a huge potential of reducing their emissions by replacing fossil fuels for generating thermal energy by thermal energy from e.g. solar collectors or biomass. It will require available spaces close to or on top of the factories to be able cover large portions of the heat demand with solar collectors. The current prices of energy from fossil fuels is low compared to their emissions and a global carbon market or taxes should be applied to accelerate the change to clean energy and lower emissions.
107

Hur kan en skola med högre energianvändning än det svenska genomsnittet energieffektiviseras? : Energikartläggning

Andersson, David, Olsson, Philip January 2017 (has links)
Europeiska unionen som helhet är en av de största energianvändarna och har en av världens största utsläpp av växthusgaser. För att minska globala uppvärmningen har mål sats upp för att medeltemperaturen på jorden inte ska öka mer än 2 grader sen förindustrielltid. Närmare 40 % av Sveriges totala energianvändning kommer från bostads- och servicesektorn detta i samband med att 2020-målen närmar sig bidrar till att energieffektiviseringar i byggnader blir allt mer essentiellt. Energikartläggningar är ett verktyg för att bestämma vad som har stört energibesparingspotential innan effektiviseringsåtgärder sker. Examensarbetet inkluderar en energikartläggning av Trödje skola som förvaltas av Gavlefastigheter. Arbetet är utfört med simuleringsverktyget IDA Indoor Climate and Energy. IDA ICE användes för att modulera den befintliga byggnaden där all data för skolan inkluderades. Rapportens vision är att undersöka hur mycket energi som är möjlig att spara genom energibesparingsåtgärder samt vilken åtgärd som är effektivast. Energibesparingspotentialen i skolan är hög, skolan använder 42,6 kWh/m2år mer än genomsnittet för Gavlefastigheters skolor vilket motsvarar 21 %. Resultaten visar att skolans komplexitet samt att påbyggnationen även kallad paviljongen är en stor faktor till att energianvändningen är hög. Skolans energianvändning har en potential att minska med 17 % vilket inte motsvarade det uppsatta 25 % - målet med arbetet. Arbetet visar att störst besparingspotential finns via byte av fönster och värmeväxlare i ventilationssystemet men även att de åtgärder som antas ge störst besparing inte alltid är effektivast. / The European Union as a whole is one of the largest energy users and has one of the world's largest greenhouse gas emissions. To reduce global warming, targets have been set to ensure that the average temperature on the earth does not increase more than 2 degrees since the pre-industrial time. Nearly 40% of Sweden's total energy use comes from the building and services sector which in context with that the 2020 targets approaching contributes to the increased need of higher energy efficiency of buildings. Energy audits is a tool for determining what has the greatest potential for saving energy before efficiency measures occurs. The thesis includes an energy audit of Trödje primary and middle school, administered by Gavlefastigheter. The study was performed using IDA Indoor Climate and Energy simulation tool. IDA ICE was used to modulate the existing building where all data for the school was included. The vision of the thesis is to investigate how much energy which is possible to save through energy saving measures and which action that is most effective. The potential energy saving in the school is high, the school uses 42.6 kWh/m2year more than the average for Gavlefastigheter schools, which corresponds to 21 %. The results show that the complexity of the school and the reconstruction, also called the paviljong, are a major factor in the high energy consumption. The school's energy use has a potential to decrease by 17 %, which did not correspond to the 25 % target set for the work. The work shows that the greatest savings potential exists through the exchange of windows and heat exchangers in the ventilation system, but also that the measures that are assumed to give the greatest savings are not always the most effective.
108

Energikartläggning av smältugnar i en aluminiumprocess : En analys av två oxyfuel-ugnars energiförbrukning, energiförluster och påverkande parametrar hos Gränges AB / Energy mapping of melting furnaces in a aluminium process : An analysis of energy consumption, energy losses and affecting parameters at two oxyfuel furnaces at Gränges AB

Johansson, Niclas, Edman, Philip January 2021 (has links)
I denna rapport har ett projekt utförts tillsammans med Gränges AB. Projektet behandlade en energianalys av deras två oxyfuel-smältugnar för smältning av aluminium. Aluminiumsmältan består till stor del av återvunnet skrot, denna metod kallas omsmältning. Ett omsmältverk kräver enorma mängder energi och därför är en minimering av ugnarnas energiförbrukning önskvärd. Smältugnarna har liknande uppbyggnad där den stora skillnaden är deras smältkapacitet, 25 ton respektive 45 ton. Trots sina likheter påvisas en skillnad i energiförbrukning mellan ugnarna vilket även skapar ett intresse för en jämförelse av ugnarna. Med en historisk datamängd som innehöll mätvärden på ett flertal parametrar togs energiförbrukningar för varje smältcykel fram. Vid jämförelser användes energiförbrukning i enheten kWh/ton. Smältcyklarnas energiförbrukning sattes in ett histogram för jämförelse mellan ugnarna. En energibalans för vardera ugn gjordes och gav förståelse var de stora förlusterna sker. Energibalansen gavs av brännarnas totalt förbrukade energi, avgasförluster, väggförluster, askaförluster, sumpförluster, nyttiga energin till aluminiet och övriga förluster. I övriga förluster inkluderades förluster vid dörröppning vilket också beräknades. Ytterligare undersöktes parametrarna dörröppningstid, sumpvikt, körningstid och vikt på tungt aluminium individuellt för att fastställa vad som påverkar energiförbrukningen mest. Detta genom att jämföra smältcyklar där endast en parameter varierar. Parametern dörröppningstid undersöktes på en djupare nivå då denna parameter kan minimeras. Resultaten påvisade att ena ugnen hade mer oregelbunden energiförbrukning än den andra vilket berodde på att den tillverkar en större variation av aluminiumlegeringar och har tillgång till en förvärmningsugn. De största förlusterna var avgasförlusterna, sumpförlusterna och övriga förluster. En stor del av övriga förluster var förluster vid dörröppning. Väggförlusterna var märkbara och askaförlusterna var minimala. Undersökning av dörröppningstid visade att dörröppningstiden påverkade energiförbrukningen markant. / A project has been carried out together with Gränges AB which treated an energy analysis of their two oxyfuel furnaces for aluminium melting. The aluminium melt largely consists of recycled scrap and this method is called secondary melting. These secondary melting plants consumes a huge amount of energy and that is why a minimization of the furnace’s energy consumption is needed. The two furnaces have similar construction, and the main difference is their melting capacity, 25 and 45 tonnes respectively. Despite their similarities a difference in energy consumption is shown which creates an interest for a comparison of the furnaces. With a collection of earlier measurement data of several parameters the energy consumption of every melting cycle could be calculated. For comparisons of energy consumptions, the unit kWh/tonne was used. The energy consumption of every melting cycle was placed in a histogram for simple comparison. An energy balance of each furnace was done which gave understanding of their major losses. The energy balance consisted of the total used energy from the burners, the flue gas losses, the wall losses, the dross losses, the slag losses, the useful energy output for aluminium and the miscellaneous heat losses. One part of the miscellaneous heat losses is the losses from door opening which also was accounted to. Furthermore, the parameters door opening duration, slag weight, the melting cycle duration and heavy aluminium weight was examined individually to understand its impact on the furnace energy consumption. This was done by comparing the melting cycles consumed energy when only one of the parameters varied. The parameter door opening duration was examined more profound because it is a parameter that can be minimized. The results showed that one of the furnaces had more irregular energy consumption. This was due to this furnace producing a higher variety of aluminium alloys and utilizing a preheating furnace. The major energy losses were flue gas losses, the slag losses, and the miscellaneous losses. The door opening duration was a major part of the miscellaneous losses. The wall losses were noticeable, and the dross losses were minimal. The examination of the parameter door opening duration showed that this parameter largely affected the furnace consumed energy.

Page generated in 0.1223 seconds