• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 13
  • Tagged with
  • 54
  • 27
  • 24
  • 24
  • 20
  • 17
  • 15
  • 10
  • 10
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Sänkta ventilationsflöden på Sundsvalls sjukhus : Utvärdering av ett energibesparingsinitiativ genom rökförsök och temperaturmätningar

Wickström, Johan January 2017 (has links)
I syfte att sänka energianvändningen på Sundsvalls sjukhus riktas nu fokus mot ventilationssystemet och möjligheterna att där sänka luftflöden. Denna uppsats undersöker detta energibesparingsinitiativ genom att studera vad som händer med luftrörelser och temperaturer i ett rum på sjukhuset vid varierande ventilationsflöden. Metoden är rökförsök med observation och analys av mätdata som jämförs med krav på inomhusklimat och beräkningar av temperatureffektiviteten, ett kvantitativt mått på hur väl tillförd värme kommer rummets vistelsezon tillgodo. Resultaten indikerar bland annat att det kan vara till nackdel för luftkvalitén med alltför drastiska ventilationsflödessänkningar i det observerade rummet, detta fastän mängden tillförd luft är mer än tillräcklig enligt gällande krav. Bäst temperatureffektivitet uppnås då frånluft går via både frånluftsdon och frånluftsfönster vilket pekar mot att bäst förutsättningar för att sänka ventilationsflöden eller tilluftstemperatur finns med denna frånluftsinställning. / With the purpose of lowering energy consumption at Sundsvall Hospital, focus is now being directed towards the ventilation system and the possibility to reduce air flow. The thesis examines this energy-saving initiative by studying what happens to air movements and temperatures in one room at the hospital when ventilation air flow is varied. Air movements were made visible with smoke and observed and temperatures were logged. Observations and data were then analyzed with regard to indoor climate requirements and temperature efficiency, a quantitative measure of how well supplied heat will benefit a room’s occupied zone. The results indicate, among other things, that a too great reduction in air flow rates can have a negative impact on the air quality in the observed room, even though the amount of air supplied is more than sufficient according to current requirements. Best temperature efficiency is achieved when exhaust air passes through both the exhaust air device and the ventilated windows, indicating that this is the most favorable exhaust air setting for lowering ventilation air flow rates or room supply air temperature.
42

Trådlös Övervakning av Inomhusklimat och PIR-baserad Passageräkning : En Demonstrationsanläggning åt Sweco Position AB

Svensson, Joakim, Yalda, Milad January 2017 (has links)
Denna rapport är ett tekniskt komplement till Johanna Hernnäs och Linnea Martinssons rapport AerQ - Ett produktutvecklingsprojekt för att läsa av inomhusklimatet. I denna rapport beskrivs designen av en demonstrationsanläggning för inomhusklimat och passageräkning bestående av två trådlösa och batteridrivna enheter för inomhusklimat respektive passageräkning och en mobilapplikation till vilket datan presenteras. Klimatenheten mäter temperatur, relativ luftfuktighet och koldioxid samt kommunicerar via Wi-Fi och BLE och visuellt via RGB-LED:s. passageräknaren detekterar passager m h a en PIR-sensor och kommunicerar via BLE. I rapporten presenteras utförandet av demoanläggninen och en undersökning av PIR-sensorer. Resultatet visar att det är möjligt att detektera riktning med en PIR-sensor samt en lösning för långvarig batteridrift av en sensornod utrustad med ljusdiodslinga, Wi-Fi och VOC-sensor(MEMS metalloxidsensor). Systemets roll kan vara att återkoppla till behovsstyrd ventilation och/eller uppmärksamma användare om sitt inomhusklimat. / This report is a technical complement to Johanna Hernnäs and Linnea Martinssons bachelor work paper AerQ - Ett produktutvecklingsprojekt för att läsa av inomhusklimatet. This report describes the design of an indoor climate and people counting demo facility consisting of two wireless and battery-powered units for indoor climate and people counting and a mobile application to which the data is presented. The climate unit measures temperature, relative humidity and carbon dioxide, and communicates via Wi-Fi and BLE and visually via RGB LEDs. The people counter detects a passage with a PIR sensor and communicates via BLE. The report presents the implementation of the demo facility and a investigation of PIR sensors. The result shows that it is possible to detect direction with a PIR sensor as well as a long-term battery operation of a sensor node equipped with RGB LEDs, Wi-Fi and VOC Sensor (MEMS Metal Oxide Sensor). The system's role may be to feedback demand-driven ventilation and / or to alert users about their indoor climate.
43

Replacing Setpoint Control with Machine Learning : Model Predictive Control Using Artificial Neural Networks

Dahlberg, Emil, Mineur, Mattias, Shoravi, Linus, Swartling, Holger January 2020 (has links)
Indoor climate control is responsible for a substantial amount of the world's total energy expenditure. In a time of climate crisis where a reduction of energy consumption is crucial to avoid climate disaster, indoor climate control is a ripe target for eliminating energy waste. The conventional method of adjusting the indoor climate with the use of setpoint curves, based solely on outdoor temperature, may lead to notable inefficiencies. This project evaluates the possibility to replace this method of regulation with a system based on model predictive control (MPC) in one of Uppsala University Hospitals office buildings. A prototype of an MPC controller using Artificial Neural Networks (ANN) as its system model was developed. The system takes several data sources into account, including indoor and outdoor temperatures, radiator flowline and return temperatures, current solar radiation as well as forecast for both solar radiation and outdoor temperature. The system was not set in production but the controller's predicted values correspond well to the buildings current thermal behaviour and weather data. These theoretical results attest to the viability of using the method to regulate the indoor climate in buildings in place of setpoint curves. / Bibehållande av inomhusklimat står för en avsevärd del av världens totala energikonsumtion. Med dagens klimatförändringar där minskad energikonsumtion är viktigt för den hållbara utvecklingen så är inomhusklimat ett lämpligt mål för att förhindra slösad energi. Konventionell styrning av inomhusklimat använder sig av börvärdeskurvor, baserade enbart på utomhustemperatur, vilket kan leda till anmärkningsvärt energispill. Detta projekt utvärderar möjligheten att ersätta denna styrmetod med ett system baserat på model predictive control (MPC) och använda detta i en av Akademiska sjukhusets lokaler i Uppsala. En MPC styrenhet som använder Artificiella Neurala Nätverk (ANN) som sin modell utvecklades. Systemet använder sig av flera datakällor däribland inomhus- och utomhustemperatur, radiatorslingornas framlednings- och returtemperatur, rådande solinstrålning såväl som prognoser för solinstrålning och utomhustemperatur. Systemet sattes inte i produktion men dess prognos stämmer väl överens med tillgänglig väderdata och husets termiska beteende. De presenterade resultaten påvisar metoden vara ett lämpligt substitut för styrning med börvärdeskurvor.
44

Energieffektivisering, en utvärdering : Undersökning och analys av energieffektivisering på Erikslunds förskola

Fornstedt, Daniel, Hedlund, Philip January 2021 (has links)
This report regards evaluating the energy and indoor climate of a pre-school located in Erikslund, Sweden which has undergone several measurers to achieve lower energy usage. The project was done on the orders of the governing municipality of Västerås and tasked to a consulting company for simulating the effects of performing these measures for lowering energy need. The municipal has together with the parliament sat goals to reach in 2020 to reduce the total energy usage by 20 %. The project had earlier installed a total of seven measures (such as new air handling unit, new lightings, adding ceiling insulation) related to energy efficiency was implemented and some ancillary construction of ventilation room. The main purposes for the study are first to analyze the energy and economical calculations and estimations done by the consulting company for the pre-school in the project stage. Then an energy mapping was done by this study to compare the earlier calculations for both the energy and economical part. The results are compared with the real values of both energy and economically data handed by Västerås stad. The theoretically energy usage calculated by the consulting company was before the measures 178 MWh/year to 65 MWh/year after. The energy mapping of this report shows before the measures 216 MWh/year to 108 MWh/year after. To compare with the real energy usage that before was 200 MWh/year, and 113,5 MWh/year after. The total cost of the project summed up to approximately $311K, which is 40 % higher than first estimated by the consulting company. The climate impact of the greenhouse gas CO2 was reduced with 12 ton yearly. Due to complications in the energy follow-up for both heat and electricity there is in the appendix attach instructional guide for Västerås stad to use in future projects regarding energy efficiencies but also evaluating the measures impact on the overall energy usage of the pre-school. The produced guide holds information regarding necessary “setup” for each type of energy efficiency measure making it possible for future evaluation (via measured data). / Denna rapport berör en undersökning av Erikslunds förskola, där syftet är att sammanställa data från flera energieffektiviserande åtgärder som har utförts under projektledning av Västerås stad. Med denna data ska det klargöras om hur väl den projekterade energieffektiviseringen stämmer överens mot den verkliga. Det utfördes även en energikartläggning för förskolan för att jämföra mot. Förskolan är belägen i Erikslunds i Västerås och har genomgått totalt sju energieffektiviserande åtgärder samt en omfattande byggåtgärd. De energirelaterade åtgärder som utförts är, tilläggsisolering av kallvind, byte av ventilationssystem (till luftbehandlingsaggregat med roterande värmeväxlare), byte av styrsystem, byte till LED belysning, nya shuntar och cirkulationspumpar, injustering av värme samt varmvattenbesparande åtgärder (perlatorer). En omfattande investering av ventilationssystem med en beräknad energibesparing på ca 80 MWh/år. Analys av investeringen visade en energibesparing på endast 40 MWh under år 2015. I helhet gav åtgärderna en lägre energibesparing än det tidigare beräknade. Den totala energibesparingen var beräknat till ca 120 MWh/år men vid mätning och verifiering uppgick den till ca 60 MWh/år. Utöver energiprestanda undersöktes även det ekonomiska utfallet. Budgeterad investeringskostnaden var ca 1,9 Mkr medan den verkliga kostnaden uppgick till ca 2,6 Mkr. Detta innebar en kostnadsökning på 40 % för projektet. Inomhusklimatet och dess påverkan av energieffektiviserande åtgärder undersöks. Detta gjordes genom en enkätundersökning samt mätningar med temperatur, CO2 och RH (relativ fuktighet) mätloggar. Resultatet av enkätundersökningen visar att det är delade åsikter, men överlag tycker personalen att den har blivit bättre fast fortfarande dålig. Mätresultatet visar att den relativa fukthalten ligger kring det undre gränsvärdet, temperaturerna varierar mellan 18-23 grader och CO2 halten steg maximalt till 825 ppm och håller sig då under gränsvärdet. Det visade sig under projektets gång att projekteringen hade brister både i planering och beräkningar. Det fattades även nödvändiga mätdata för utvärdering av energiprestanda. Slutsatsen blev att investeringarna ej är lönsamma och för att undvika detta i framtida projekt utarbetades en instruktion med tillhörande checklista som finns bifogat under bilagor. Västerås stad kan använda den i framtiden för att undvika att missa viktiga delar som behövs för framtida verifieringar av energiprestanda. Rapporten har i litteraturstudien undersökt redan framtagna guider med checklistor till exempelvis SVEBYS energiavtal 12 som handlar om att i energieffektiviseringsprojekt strukturera upp och öka kvalitén dels för att minska skillnaden mellan projekterad och verkligt utfall, dels för att undvika missar i planeringen. Det har även undersökts liknande energieffektiviseringsprojekt där uppföljning utförts vilket visar att det ofta blir en skillnad mellan projekterad energisimulering samt verkligt utfall, det finns exempel både på när det blir bättre och sämre samt vad det beror på.
45

Klimatsmarta Hyresgäster : Potential hos hyresgästen för minskning av energianvändning i en kontorsbyggnad på ett klimatsmart sätt / Climate friendly Tenants : Potential for tenants to reduce energy consumption in an office building in a climate manner

Lausevic, David January 2013 (has links)
The starting point for this master thesis was the product of the company "Humlegården", which allows its tenants in office buildings to follow their electricity consumption in real time, through their Smartphone's. The idea that resulted from that application is to investigate if it is possible to direct the tenants in office buildings to reduce their energy consumptions, but also to be satisfied with the indoor environment. This work addresses the factors which are the main energy consumers in office buildings. It addresses legal requirements and standards which are important to follow in order to achieve good thermal comfort in buildings. Some of them are physical climate factors like thermal environment, air quality and lightning. Investigation has also been made on psychological, physiological and social factors which are important for human’s thermal perception. Even monitoring methods for energy and comfort have been discussed as well as methods that are used to ensure the thermal perception of human beings. Through literature studies that have been carried out in the past, especially those who determine the connection between physical and psycho-social elements, a simple suggestion has been made. The suggestion is based on indoor and outdoor temperature, that should direct the tenant to allow in some cases lower indoor temperature which will lead to minimized energy consumption.
46

Inomhusklimat : En studie om fastigheter uppfyller krav som ställs på inomhus klimatet och hur brukarnas upplevelse av detta / Indoor climate : A study on how real estate complies with the requirements of the indoor climate and how the users experience it

Nilsson, Felix, Johansson, Andreas January 2017 (has links)
Människans välmående och förmåga att prestera optimalt påverkas av inomhusklimatet. de främsta faktorerna som påverkar människans upplevelse av detta är luftkvalitet, ljus och ljudnivåer.I den här rapporten vill vi ta reda på hur en byggnad som vi har valt lever upp till de krav som ställs på inomhusklimatet, ta reda på hur personer i byggbranschen ser på/värderar inomhusklimatet och hur det arbetar för att uppfylla kraven på ett bra inomhusklimat. För att ta reda på detta har vi använt oss av handlingar för det huset vill valt, intervjuer med branschfolk samt en enkätundersökning som delats ut till brukarna av byggnaden.Byggnaden uppfyller de krav som ställs på ljud, ljus, luftkvalité, värmekomfort på vinterhalvåret och värmekomfort på sommarhalvåret enligt miljöbyggnad gulds kriterier för projekterande värden. Enligt vår enkät undersökning med 46 deltagare där frågor som tagits fram av Sweden Green Building Council som handlar om hur nöjda brukarna är med inomhusklimatet klarade ljud, ljus och luftkvalitet kraven på nöjdhet som ska vara minst 80 % av deltagarna. Värmekomforten i byggnaden klarade däremot inte kraven på både vinter och sommarhalvåret.Slutsatsen från den här studien är att i byggnaden överlag håller en hög standard men att det går att göra förbättringar i värmesystemen i form av injusteringar av ventilation och sekundärvärme. Deltagarna var väldigt nöjda med dagsljus och vi kom fram till slutsatsen att på grund av de stora fönsterytorna som skapar detta är det svårt att få en bra värmekomfort i fastigheten då alla typer av öppningar för med sig värmeförluster.De företag och personer vi har varit i kontakt med jobbar alla aktivt med inomhusklimat frågor både i projekteringsstadiet och i brukar stadiet. De ser alla en positiv framtid för den fortsatta utvecklingen av inomhusklimatet och att det är en av de viktigaste frågor man ställs inför vid uppförande av fastigheter. / Human well-being and ability to perform optimally are affected by the indoor climate. The main factors that affect the human experience of this are air quality, light and noise levels.In this report we want to find out how a building we have chosen meets the requirements of the indoor climate, find out how people in the construction industry are looking at/appreciating the indoor climate and how they work to meet the requirements for a good indoor climate. To research this we have used documents from the house we choose, interviews with industry people and a survey conducted to the users of the building.The building meets the requirements for sound, light, air quality, warmth comfort during the winter and heat comfort during the summer months according to the environmental building gold criteria for projected values. According to our survey, a survey of 46 participants where questions raised by the Swedish Green Building Council, which deal with how satisfied the users are with the indoor climate, sound, light and air quality achieved the satisfaction requirements that should be at least 80%. However, the heating comfort in the building did not meet the demands in winter and summertime's.The conclusion from this study is that the building in general has a high standard but that improvements in heating systems can be made in form of adjustments of ventilation and secondary heating. The participants were very happy with daylight and we came to the conclusion that because of the large windows that create this, it is difficult to get a good heating comfort in the property as all types of openings bring heat losses.The companies and people we have been in contact with, all actively work with indoor climate issues, both at the design stage and at the user stage. They all see a positive future for the continued development of the indoor climate and that it is one of the most important issues facing the construction of real estate
47

The WELL Building StandardA Study of Bengt Dahlgren's office in Stockholm

Landmark, David January 2019 (has links)
Throughout our lives, we spend approximately 80–90% of our time indoors, and the environment which wereside in is a key factor determining our comfort and well-being. A favorable indoor environment can enhance our quality of life whereas a less than favorable environment may have the opposite effect. A key ambition of several Green Building Certifications is the desire to reduce a building’s environmental impact and energy consumption, and, in addition, the ambition to provide a satisfying indoor environment.The WELL Building Standard (WELL) is an up and coming green building certification explicitly embracing comfort, health and well-being in the built environment. The standard covers seven over-arching topics forwhich the indoor environment is evaluated by; Air, Water, Nourishment, Light, Fitness, Comfort, andMind. Compared to well-established Green Building Certifications like LEED, BREEAM and Miljöbyggnad, the WELL standard is newly introduced on the Swedish market with few current applications. The purpose of this report is to apply WELL for Bengt Dahlgren’s office in Stockholm and provide resultsdemonstrating to what extent the office satisfies the certification. The report will also provide recommendedmeasures so as to reach a desired WELL certification grade. Furthermore, the compliance between WELL and the Swedish Green Building Certification Miljöbyggnad will be studied. The study has been carried out byreviewing the relevant policy, property and equipment documents; conducting technical measurements; andinspecting the conditions of the office area and its surroundings. Correspondence with stakeholders and actorsknowledgeable of the current state of the office have been a constant element throughout the project.  The results show that Bengt Dahlgren’s office currently do not fulfill the required preconditions to be eligiblefor a WELL certification. However, if those preconditions were to be addressed, a completed certificationwould result in a grade corresponding to Silver. By implementing the recommendations provided by the authorit should also be possible to reach the higher certification grade Gold. The study furthermore concludes that WELL and Miljöbyggnad only demonstrate limited overlap. By evaluating Bengt Dahlgren’s office in Stockholm, this report strives to give insight for how a Swedish office facility comply with the WELL certification. The work should also give light to new perspectives and applications regarding health, comfortand well-being which may not be included in traditional Green Building Certifications. The compliance for WELL with Swedish regulations, standards and norms have been treated in this report, however, the topic can be suggested as an area for future work, as there is room for an explicit study concerning this. / Vi spenderar uppskattningsvis 80–90% av våra liv inomhus och miljön vi vistas i är en avgörande faktor för vårhälsa och välmående. En gynnsam inomhusmiljö kan förhöja vår livskvalité medan en ogynnsam miljö kan haden motsatta effekten. En väsentlig ambition för flera miljöcertifieringar är önskan att reducera byggnaders miljöpåverkan och energikonsumtion, samt, därutöver, strävan efter att förse en behaglig inomhusmiljö.WELL Building Standard (WELL) är en miljöcertifiering som uteslutande behandlar komfort, hälsa och välmående i inomhusmiljön. Certifieringen täcker sju övergripande koncept som inomhusmiljön utvärderasefter; Luft, Vatten, Kost, Ljus, Motion, Komfort och Sinnesupplevelse. Jämfört med konventionellamiljöcertifieringar som LEED, BREEAM och Miljöbyggnad så är WELL nyintroducerad på den svenskamarknaden med få tillämpningar i dagsläget. Syftet med det här arbetet är att applicera WELL för Bengt Dahlgrens kontor i Stockholm och frambringa resultatet som visar på hur väl kontoret uppfyller certifieringen. Arbetet kommer även tillhandahållare kommenderade åtgärder för hur en önskad certifieringsnivå kan nås. Därutöver kommer överenstämmelsen mellan WELL och den svenska miljöcertifieringen Miljöbyggnad studeras. Arbetat har utförts genomgranskning av relevanta policy-, fastighets- och utrustningsdokument; utförande av tekniska mätningar; och inspektioner av förhållanden vid kontoret och dess omgivning. Korrespondens med aktörer närvarande vid byggnadens uppförande samt aktörer insatta i byggnadens nuvarande förhållanden har hållits genomgående under projektets gång. De framtagna resultaten visar på att Bengt Dahlgrens kontor i nuläget inte uppfyller de nödvändiga skallkrav för att vara berättigad en certifiering. Ifall dessa skallkrav vore åtgärdade skulle en certifiering generera ett betygmotsvarande Silver. Genom att implementera de åtgärder som rekommenderas av författaren kan kontoret även nå det högre betyget Guld. Arbetet visar dessutom på att WELL och Miljöbyggnad endast erhåller en begränsad överensstämmelse. Genom att utvärdera Bengt Dahlgrens kontor i Stockholm ämnar det här arbetetge en insikt i hur en svensk fastighet står sig gentemot WELL. Arbetet hoppas också ge utrymme åt nya perspektiv och tillämpningar av hälsa, komfort och välmående i byggnader, som kanske inte är inkluderade i traditionella miljöcertifieringar. Överensstämmelsen för WELL med svenska regler, standarder och normer kan föreslås som ett område lämpligt för framtida studier. Även om detta ämne har studerats i denna rapport så finns det utrymme för att genomföra en djupare studie som behandlar detta.
48

The Effect of Global Warming on the Indoor Environment : A Simulation Study on Single – Family Houses in the Stockholm Region

Andersson, Julia, Larsson, Fredrik January 2021 (has links)
In this thesis, the main objective has been to simulate and evaluate the change between the indoor climate today and 2070, due to climate change. The model created was built by parts chosen based on solutions and material commonly used when building single-family houses in the Stockholm region in 2020. This has been done by evaluating statistics, literature, common practices, and building requirements. To simulate a representative house, a model was built in the software IDA ICE where present and future climates were inserted and the resulting indoor environment evaluated. The future outdoor climate has been constructed through predictions based on scenarios determined by the Intergovernmental Panel on Climate Change (IPCC). The hypothesis was that single-family houses built in 2020 will not be habitable in 2070 due to the increased indoor temperatures in summer, and that changes can be done to combat this potential warming.The result of the simulations shows that the indoor environment was strongly dependent on the outdoor climate, building design, and technique. Meaning that changes to the building, regarding design, structure, material, and building services will result in a change in the indoor environment. Furthermore, the indoor temperatures of the model increased above acceptable levels regardless of future scenario. Several changes and additions to the model have, therefore, been tested to examine whether they reduce the maximum temperatures below the threshold sustainably.None of the individual changes reduced the temperatures below the acceptable levels for every single scenario and was considered a sustainable option at the same time. Some more sustainable modifications reduced the indoor temperatures below the threshold for the cooler scenarios, and some less sustainable modifications reduced the indoor temperatures below the threshold for all scenarios. A combination of more sustainable modifications was also tested, yielding a reduction in temperature beneath the threshold for all scenarios except for the two most extreme.The changed outdoor climate has a large effect on the simulated indoor environment. This could be considered as a strong indication that the actual indoor environment and thermal comfort of single-family houses will be affected as well. It is difficult to predict whether single-family houses in 2070 will be considered unhabitable since it is determined by a wide range of variables. The simulated indoor environment can, however, be improved by changing or adding parts to the model. / Denna uppsats huvudsakliga mål har varit att simulera och utvärdera förändringen mellan inomhusklimatet idag och år 2070 på grund av klimatförändringarna. Den skapade modellen var uppbyggd av delar valda utifrån lösningar och material som vanligtvis används vid byggandet av småhus i Stockholmsregionen 2020. Detta har gjorts genom att utvärdera statistik, litteratur, vanliga metoder och byggregler. För att simulera ett representativt hus byggdes en modell i mjukvaran IDA ICE. Modellen testades mot ett nuvarande och framtida utomhusklimat och därefter utvärderades den resulterande inomhusmiljön Det framtida utomhusklimatet har konstruerats genom prognoser baserade på scenarier som bestäms av FN:s klimatpanel (IPCC). Hypotesen var att småhus som byggts runt 2020 inte kommer att vara beboeliga år 2070 på grund av de ökade inomhustemperaturerna på sommaren, och att förändringar kan göras för att bekämpa denna potentiella uppvärmning av inomhustemperatur.Resultaten av simuleringarna visar att inomhusmiljön var starkt beroende av utomhusklimatet, byggtekniken och designen. Vilket betyder att förändringar i byggnaden avseende design, stomme, material och installationsteknik kommer att resultera i en förändring av inomhusmiljön. Fortsatt steg inomhustemperaturerna i modellen över acceptabla nivåer, oavsett framtida scenario. Flera ändringar och tillägg till modellen har därför testats, för att undersöka om det kan leda till en sänkning av den maximala temperaturen under riktvärdet, på ett hållbart sätt.Ingen av de individuella förändringarna minskade temperaturerna under de acceptabla nivåerna för alla scenarier samt ansågs vara ett hållbart alternativ. Några mer hållbara ändringar minskade inomhustemperaturerna under riktvärdet för de svalare scenarierna. Medan vissa mindre hållbara modifieringar minskade temperaturerna under kravet för alla scenarier. En kombination av de mer hållbara modifieringar testades också, vilket sänkte temperaturerna under tröskelvärdet för alla scenarier, utom de två mest extrema.Det förändrade utomhusklimatet har stor inverkan på den simulerade inomhusmiljön. Detta kan ses som en stark indikation på att den verkliga inomhusmiljön och termiska komforten för småhus också kommer att påverkas i framtiden. Det är svårt att förutsäga huruvida småhus år 2070 kommer att betraktas som obeboeliga då det påverkas av många variabler. Den simulerade inomhusmiljön kan dock förbättras genom att ändra eller lägga till delar i modellen.
49

Energibalans och inomhusklimat i ett parkeringshus under jord med behovsstyrd ventilation / Energy balance and indoor climate in a parking garage underground with demand-controlled ventilation

Pohjanen, Alexander January 2017 (has links)
Detta examensarbete är gjort hos VVS-konsulterna Skellefteå AB. Det behandlar projektering av ett parkeringshus med hänsyn till värme och ventilation och en jämförelse av ventilationssystem på ett parkeringshus som är planerad att stå klar 2019. Syftet med arbetet är att undersöka hur man projekterar ett parkeringshus ventilation och om det går att spara energi och utgifter genom att använda sig av behovsstyrd ventilation istället för konstant ventilation. Eftersom det är dyrare att investera i behovsstyrd ventilation kommer det också undersöka återbetalningstiden för den investeringen. För att göra undersökningarna har programmet IDA ICE använts för att rita upp en modell av byggnaden och simulera dess energianvändning för att senare jämföra resultaten och se skillnaderna mellan de olika ventilationssystemen. Ett förslag har framtagits på hur ventilationen kan dras och hur fläktluftvärmare ska installeras och hur rören ska dras. Resultatet från simuleringarna gav den totala energiförbrukningen minskade med 705 000 kWh/ med behovsstyrd ventilation jämfört med konstant ventilation. Fläktens energianvändning minskade med 75% och uppvärmningsenergin minskade med 72%. Investeringen för behovsstyrd ventilation jämfört med konstantflödes ventilation är 600 000 kr dyrare och får utifrån beräkningarna i detta arbete en återbetalningstid på 1 år. Livslängden på ventilationssystemet antas vara 25–30 år. / This graduate work was conducted in cooperation with the VVS-Consultants Skellefteå AB. It deals with the design of a parking garage regarding heat and ventilation and a comparison of ventilation systems in a parking garage that is scheduled to be ready 2019. The purpose of the work is to investigate how to design a parking garage ventilation and if you can save energy and expenses by using demand-controlled ventilation instead of constant ventilation. As it is more expensive to invest in demand- controlled ventilation, it will also investigate the repayment period for that investment. To do the studies, the IDA ICE program has been used to draw a model of the building and simulate its energy use to compare the results later and see the differences between the different ventilation systems. A proposal has been made on how ventilation can be drawn and how the radiators are to be installed and how the pipes are to be drawn. The result of the simulations resulted in total energy consumption decreased by 705,000 kWh / with demand-controlled ventilation compared to constant ventilation. The fan's energy consumption decreased by 75% and the heating energy decreased by 72%. The investment for controlled ventilation compared to constant flow ventilation is 600,000 kr more and, based on the calculations in this work the repayment period is 1 year. The life expectancy of the ventilation system is assumed to be 25-30 years.
50

Projektering och energieffektivisering av värme- och ventilationssystem för ett flerbostadshus vid Vänern / Design and Energy Efficiency Calculations of the Heating and Ventilation System in a Building with Apartments Located at the lake Vänern in Sweden

Burrows, Michel January 2021 (has links)
En fastighet med ett antal lägenheter lokaliserad i den lilla tätorten Otterbäcken i Gullspångs kommun har brunnit ner. Fastigheten kommer att byggas upp på nytt igen. Det kommer att ske i enlighet med Boverkets byggregel BBR och de krav som är aktuella för 2021. Examensarbetet har varit ett samarbete mellan Högskolan i Borås och konsultföretaget Energitriangeln AB i Göteborg. Examensarbetet omfattar en ny projektering av fastigheten med avseende på val av teknisk lösning för uppvärmningssystemet och ventilationen. Som hjälp i projekteringen användes simuleringsprogrammet ”MagiCad från företaget Autodesk. De energitekniska beräkningarna av uppvärmningsbehovet genomfördes i simuleringsprogrammet BV2, ”Byggnadens Värmebalans i Varaktighetsdiagrammet” som tillhandahålls av företaget CIT, Chalmers Industriteknik. Den tekniska lösningen för lägenhetshuset omfattar en förbättring från den ursprungliga ventilationen som var ett självdragssystem till att bli antingen ett till- och frånluftssystem med värmeåtervinning, (FTX) eller ett frånluftssystem där värmeåtervinning i frånluften erhålls med hjälp av en frånluftvärmepump. Båda alternativen för en förbättrad ventilation projekterades med MagiCad programmet. Examensarbetet omfattar även en analys och beräkning av fastighetens energiprestanda med hjälp av simuleringsprogrammet BV2. Genom användningen av BV2 beräknades två fall och resultatet uttrycktes i specifik energiförbrukning av både el och värme i kWh/m2, år. Dels för fastigheten som projekteras med ett FTX- system för ventilationen och för projektering av en frånluftvärmepump för värmeåtervinning ur frånluften. För att kunna utföra detta projekt behövdes det bland annat tillgång till byggnadsritningar på den fastighet som håller på att byggas och projekteras oberoende av detta examensarbete. Syftet och huvudmålet med rapporten är att ge färdigheter och kunskap inom användningen och konfigurering av simuleringsprogrammet BV2 för energieffektivisering och på det viset kunna göra en jämförelse mellan två olika lösningar ur en ekonomisk synpunkt. Det är också viktigt att visa om de två tekniska lösningarna för ventilationen ger en energi-prestanda som överensstämmer med de krav som ingår Boverkets byggregler, BBR 28 från år 2019. Som en fortsättning av kursen CAD för VVS installationer ingick i examensarbetet en projektering av värme sekundär VS, tappvarmvatten, tappkallvatten och spillvatten med hjälp av MagiCad. Metodiken för energiprestandaberäkningarna i detta projekt var att mäta arean på skalet i fasaden, fönster och dörrar på byggnaden och använda som indata i simuleringsprogrammet av BV2. Resultatet av examensarbetet konstaterar att valet av en bergvärmepump är det bästa alternativet ur en ekonomisk synvinkel. Detta eftersom man behöver köpa färre antal kilowattimmar elektricitet för att kunna täcka värmebehovet i huset. Väljer man en bergvärmepump med ett FTX aggregat sparas i köpt värme för att kunna tillfredsställa fastighetens energibehov cirka 12 527 kWh/el som ger med ett rörligt elpris cirka 14 907 kr om året i besparing av köpt el för värmeproduktion i jämförelse med alternativet där en frånluftsvärmepump användes för värmeåtervinning från frånluften och där den kalla tilluften värms med en utökad area på radiatorsystemet. / A property with several apartments located in the small village of Otterbäcken in Gullspång municipality has burned down. The property will be rebuilt in accordance with Boverket buildings rules BBR and the requirements that are relevant for 2021.The diploma project has been a collaboration between the University of Borås and the consulting company Energi Triangeln AB located in the city of Gothenburg. As part of the project a re-design of the heating and ventilation system of the property will be carried out using two different simulation programs used when designing buildings. The first program is MagiCad from the company Autodesk. In this program drawings are made of the building including the drawings of the heating and ventilation systems. The second program is more focused at energy balances and energy efficiency calculation of the property. You get the energy performance of the property. The translated name is “Heat balances in a duration diagram”. The program is developed by a consulting company connected to Chalmers University of Technology named “Chalmers Industrial Technology”, CIT. The original technical solution for the ventilation in the building before it burned down was a system not using any fans. When rebuilding the house, the design of the ventilation system includes the comparison of two modern system both using extraction fans for forcing spent air to leave the building. The first alternative uses both a supply fan and exhaust fan with a heat exchanger for heat recovery of the heat in the exhaust ventilation duct. This system is used together with a heat pump taking heat from the ground. The second technical solution of ventilation system uses an exhaust fan in connection to a heat pump. That is a system where the heat recovery of the heat in the exhaust duct is recovered in the heat pump instead of extracting heat from the ground as in alternative one. Alternative two has no centralized intake of ventilation air, instead fresh air is coming into the apartments below windows in the sleeping rooms and living room of the apartments through individual ducts. By using the program energy performance program “BV2”, two different cases were calculated and expressed in specific energy consumption of both electricity and heat using the unit kWh/m2, per year. This means that the property which was designed with both an exhaust and a supply fan (and heat exchanger) for ventilation of the building and for the design with an exhaust air fan only but using a heat pump for heat recovery from the exhaust air, these two cases can be compared. To be able to carry out this project, it was necessary, among other things there was a need to access proper building drawings of the property that is being built and projected. The purpose and main objectives of the project are fulfilled. Furthermore, as a continuation of the course called “Computed Aided Design, (CAD), for buildings, the design of secondary heating, domestic hot and cold water and sewage water was carried out using MagiCad. The method used to carry out this project was to use the drawings of the building, measure the area of the shell, windows, doors, roofs and floor of the building and by using the second simulation program BV2 to be able to calculate the energy required of the building. The result of the degree project states that the choice of a geothermal heat pump with a heat exchanger for heat recovery between the exhaust duct and the duct with incoming fresh air provides the best alternative from an energy performance perspective. You consume fewer kilowatt hours to be able to cover the heating demand in the building. If you choose a geothermal heat pump with a heat recovery using only a heat exchanger the saving in purchased electricity to be able to satisfy the property´s energy demand is approximately 12 527 kWh/ electricity annually. which with a common electricity price in Sweden, (of 1.19 crowns/kWh) provides approximately 14 900 Swedish crowns per year in savings of purchased electricity for heat production.

Page generated in 0.0499 seconds