• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 13
  • Tagged with
  • 56
  • 29
  • 24
  • 24
  • 21
  • 17
  • 15
  • 11
  • 10
  • 9
  • 8
  • 8
  • 8
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Energibalans och inomhusklimat i ett parkeringshus under jord med behovsstyrd ventilation / Energy balance and indoor climate in a parking garage underground with demand-controlled ventilation

Pohjanen, Alexander January 2017 (has links)
Detta examensarbete är gjort hos VVS-konsulterna Skellefteå AB. Det behandlar projektering av ett parkeringshus med hänsyn till värme och ventilation och en jämförelse av ventilationssystem på ett parkeringshus som är planerad att stå klar 2019. Syftet med arbetet är att undersöka hur man projekterar ett parkeringshus ventilation och om det går att spara energi och utgifter genom att använda sig av behovsstyrd ventilation istället för konstant ventilation. Eftersom det är dyrare att investera i behovsstyrd ventilation kommer det också undersöka återbetalningstiden för den investeringen. För att göra undersökningarna har programmet IDA ICE använts för att rita upp en modell av byggnaden och simulera dess energianvändning för att senare jämföra resultaten och se skillnaderna mellan de olika ventilationssystemen. Ett förslag har framtagits på hur ventilationen kan dras och hur fläktluftvärmare ska installeras och hur rören ska dras. Resultatet från simuleringarna gav den totala energiförbrukningen minskade med 705 000 kWh/ med behovsstyrd ventilation jämfört med konstant ventilation. Fläktens energianvändning minskade med 75% och uppvärmningsenergin minskade med 72%. Investeringen för behovsstyrd ventilation jämfört med konstantflödes ventilation är 600 000 kr dyrare och får utifrån beräkningarna i detta arbete en återbetalningstid på 1 år. Livslängden på ventilationssystemet antas vara 25–30 år. / This graduate work was conducted in cooperation with the VVS-Consultants Skellefteå AB. It deals with the design of a parking garage regarding heat and ventilation and a comparison of ventilation systems in a parking garage that is scheduled to be ready 2019. The purpose of the work is to investigate how to design a parking garage ventilation and if you can save energy and expenses by using demand-controlled ventilation instead of constant ventilation. As it is more expensive to invest in demand- controlled ventilation, it will also investigate the repayment period for that investment. To do the studies, the IDA ICE program has been used to draw a model of the building and simulate its energy use to compare the results later and see the differences between the different ventilation systems. A proposal has been made on how ventilation can be drawn and how the radiators are to be installed and how the pipes are to be drawn. The result of the simulations resulted in total energy consumption decreased by 705,000 kWh / with demand-controlled ventilation compared to constant ventilation. The fan's energy consumption decreased by 75% and the heating energy decreased by 72%. The investment for controlled ventilation compared to constant flow ventilation is 600,000 kr more and, based on the calculations in this work the repayment period is 1 year. The life expectancy of the ventilation system is assumed to be 25-30 years.
52

Projektering och energieffektivisering av värme- och ventilationssystem för ett flerbostadshus vid Vänern / Design and Energy Efficiency Calculations of the Heating and Ventilation System in a Building with Apartments Located at the lake Vänern in Sweden

Burrows, Michel January 2021 (has links)
En fastighet med ett antal lägenheter lokaliserad i den lilla tätorten Otterbäcken i Gullspångs kommun har brunnit ner. Fastigheten kommer att byggas upp på nytt igen. Det kommer att ske i enlighet med Boverkets byggregel BBR och de krav som är aktuella för 2021. Examensarbetet har varit ett samarbete mellan Högskolan i Borås och konsultföretaget Energitriangeln AB i Göteborg. Examensarbetet omfattar en ny projektering av fastigheten med avseende på val av teknisk lösning för uppvärmningssystemet och ventilationen. Som hjälp i projekteringen användes simuleringsprogrammet ”MagiCad från företaget Autodesk. De energitekniska beräkningarna av uppvärmningsbehovet genomfördes i simuleringsprogrammet BV2, ”Byggnadens Värmebalans i Varaktighetsdiagrammet” som tillhandahålls av företaget CIT, Chalmers Industriteknik. Den tekniska lösningen för lägenhetshuset omfattar en förbättring från den ursprungliga ventilationen som var ett självdragssystem till att bli antingen ett till- och frånluftssystem med värmeåtervinning, (FTX) eller ett frånluftssystem där värmeåtervinning i frånluften erhålls med hjälp av en frånluftvärmepump. Båda alternativen för en förbättrad ventilation projekterades med MagiCad programmet. Examensarbetet omfattar även en analys och beräkning av fastighetens energiprestanda med hjälp av simuleringsprogrammet BV2. Genom användningen av BV2 beräknades två fall och resultatet uttrycktes i specifik energiförbrukning av både el och värme i kWh/m2, år. Dels för fastigheten som projekteras med ett FTX- system för ventilationen och för projektering av en frånluftvärmepump för värmeåtervinning ur frånluften. För att kunna utföra detta projekt behövdes det bland annat tillgång till byggnadsritningar på den fastighet som håller på att byggas och projekteras oberoende av detta examensarbete. Syftet och huvudmålet med rapporten är att ge färdigheter och kunskap inom användningen och konfigurering av simuleringsprogrammet BV2 för energieffektivisering och på det viset kunna göra en jämförelse mellan två olika lösningar ur en ekonomisk synpunkt. Det är också viktigt att visa om de två tekniska lösningarna för ventilationen ger en energi-prestanda som överensstämmer med de krav som ingår Boverkets byggregler, BBR 28 från år 2019. Som en fortsättning av kursen CAD för VVS installationer ingick i examensarbetet en projektering av värme sekundär VS, tappvarmvatten, tappkallvatten och spillvatten med hjälp av MagiCad. Metodiken för energiprestandaberäkningarna i detta projekt var att mäta arean på skalet i fasaden, fönster och dörrar på byggnaden och använda som indata i simuleringsprogrammet av BV2. Resultatet av examensarbetet konstaterar att valet av en bergvärmepump är det bästa alternativet ur en ekonomisk synvinkel. Detta eftersom man behöver köpa färre antal kilowattimmar elektricitet för att kunna täcka värmebehovet i huset. Väljer man en bergvärmepump med ett FTX aggregat sparas i köpt värme för att kunna tillfredsställa fastighetens energibehov cirka 12 527 kWh/el som ger med ett rörligt elpris cirka 14 907 kr om året i besparing av köpt el för värmeproduktion i jämförelse med alternativet där en frånluftsvärmepump användes för värmeåtervinning från frånluften och där den kalla tilluften värms med en utökad area på radiatorsystemet. / A property with several apartments located in the small village of Otterbäcken in Gullspång municipality has burned down. The property will be rebuilt in accordance with Boverket buildings rules BBR and the requirements that are relevant for 2021.The diploma project has been a collaboration between the University of Borås and the consulting company Energi Triangeln AB located in the city of Gothenburg. As part of the project a re-design of the heating and ventilation system of the property will be carried out using two different simulation programs used when designing buildings. The first program is MagiCad from the company Autodesk. In this program drawings are made of the building including the drawings of the heating and ventilation systems. The second program is more focused at energy balances and energy efficiency calculation of the property. You get the energy performance of the property. The translated name is “Heat balances in a duration diagram”. The program is developed by a consulting company connected to Chalmers University of Technology named “Chalmers Industrial Technology”, CIT. The original technical solution for the ventilation in the building before it burned down was a system not using any fans. When rebuilding the house, the design of the ventilation system includes the comparison of two modern system both using extraction fans for forcing spent air to leave the building. The first alternative uses both a supply fan and exhaust fan with a heat exchanger for heat recovery of the heat in the exhaust ventilation duct. This system is used together with a heat pump taking heat from the ground. The second technical solution of ventilation system uses an exhaust fan in connection to a heat pump. That is a system where the heat recovery of the heat in the exhaust duct is recovered in the heat pump instead of extracting heat from the ground as in alternative one. Alternative two has no centralized intake of ventilation air, instead fresh air is coming into the apartments below windows in the sleeping rooms and living room of the apartments through individual ducts. By using the program energy performance program “BV2”, two different cases were calculated and expressed in specific energy consumption of both electricity and heat using the unit kWh/m2, per year. This means that the property which was designed with both an exhaust and a supply fan (and heat exchanger) for ventilation of the building and for the design with an exhaust air fan only but using a heat pump for heat recovery from the exhaust air, these two cases can be compared. To be able to carry out this project, it was necessary, among other things there was a need to access proper building drawings of the property that is being built and projected. The purpose and main objectives of the project are fulfilled. Furthermore, as a continuation of the course called “Computed Aided Design, (CAD), for buildings, the design of secondary heating, domestic hot and cold water and sewage water was carried out using MagiCad. The method used to carry out this project was to use the drawings of the building, measure the area of the shell, windows, doors, roofs and floor of the building and by using the second simulation program BV2 to be able to calculate the energy required of the building. The result of the degree project states that the choice of a geothermal heat pump with a heat exchanger for heat recovery between the exhaust duct and the duct with incoming fresh air provides the best alternative from an energy performance perspective. You consume fewer kilowatt hours to be able to cover the heating demand in the building. If you choose a geothermal heat pump with a heat recovery using only a heat exchanger the saving in purchased electricity to be able to satisfy the property´s energy demand is approximately 12 527 kWh/ electricity annually. which with a common electricity price in Sweden, (of 1.19 crowns/kWh) provides approximately 14 900 Swedish crowns per year in savings of purchased electricity for heat production.
53

Styrning av värmesystem i kontorsbyggnader : Jämförelse mellan prognosstyrning, styrning som utnyttjar byggnadens värmetröghet, samt traditionell styrning

Larmérus, Alexander January 2014 (has links)
En stor del av Sveriges energianvändning går till bostäder och lokaler. Ur en nationell synvinkel är energieffektiviseringar i befintliga byggnader därför en potentiellt viktig del för att kunna nå de satta klimatmålen till år 2020. I ett traditionellt styr- och reglersystem styrs framledningstemperaturen i ett vätskeburet värmesystem efter en kurva som beror på utomhustemperaturen. En del nya styr- och reglersystem tar även hänsyn till andra parametrar, såsom byggnaders värmetröghet och lokala väderprognoser. Ett exempel på ett sådant system är Ecopilot, utvecklat av Kabona. Nuvarande kunskap angående hur stor energibesparing som styr- och reglersystem med prognosstyrning och styrning som utnyttjar byggnadens värmetröghet ger upphov till består till största del av referensfall som jämför byggnaders energianvändning före och efter installationen. I detta examensarbete undersöktes hur energianvändning och inomhusklimat påverkades av prognosstyrning och styrning som utnyttjar byggnaders värmetröghet. Mätningar utfördes på två kontorsbyggnader vid namn Fräsaren 10 och Fräsaren 11. Båda byggnaderna är belägna i Sundbyberg och har Kabona Ecopilot installerat. Mätdata loggades genom redan utsatta givare och en enklare form av validering av dessa gjordes. I Fräsaren 10 och Fräsaren 11 jämfördes Ecopilot i normal drift med driftfallet då prognosstyrningsfunktionen stängdes av i Ecopilot. Även ett tredje driftfall undersöktes i Fräsaren 10. Under detta driftfall stängdes Ecopilot av och framledningstemperaturen styrdes med hjälp av reglerkurvor. I luftbehandlingsaggregaten sattes tilluftstemperaturens börvärde, till 19-20 °C. Varje driftfall hade en mätperiod på minst 14 dagar. Energisignaturer användes för att jämföra energianvändningen och en osäkerhetsanalys av de anpassade linjerna gjordes. En egen modell för att undersöka toppbelastningar i radiatorsystemet, VS1, i Fräsaren 10 togs fram. Även en modell för att undersöka hur temperaturen varierat inomhus mellan de olika mätperioderna togs fram. Energisignaturer för radiatorsystemen VS1 och VS2 i Fräsaren 10 visade på att likvärdiga energisignaturer kunde fås för samtliga av de undersökta driftfallen under det temperaturintervall som undersöktes. Energisignaturer för värmeanvändning i luftbehandlingsaggregatet, LB2601, visade på att en konstant tillufttemperatur på 19 °C som användes då Ecopilot var avstängd, kunde ge en högre värmeanvändning jämfört med fallen då Ecopilot var i normal drift och då Ecopilot hade sin prognosstyrning avstängd. Från jämförelse mellan fallen då Ecopilot var i normal drift och då Ecopilots prognosstyrning var avstängd kunde inga substantiella skillnader hittas mellan energisignaturerna. Det betyder dock inte att prognosstyrningen inte ger upphov till energibesparingar, utan att eventuella energibesparingarna var för små relativt mätningarnas osäkerhet vid en konfidensnivå på 65 % eller 95 %. Osäkerheten kan minskas om mätningar utförs över en längre tidsperiod än som var möjligt under detta examensarbete. Värmetoppbelastningar som undersöktes i radiatorsystemet i VS1 Fräsaren 10 visade inte på att några signifikanta skillnader mellan antalet uppmätta värmeeffekttoppar under de olika mätperioderna. Det förekom dock en viss indikation att det kan leda till fler värmeeffekttoppar om prognosstyrningen stängs av i Ecopilot. För att få ett mer tillförlitligt resultat behöver mätningar göras under en längre tidsperiod. Inomhustemperaturen undersöktes i Fräsaren 10 och Fräsaren 11. I Fräsaren 10 uppgick medeltemperatur till 21,5 °C för fallen då Ecopilot var i normal drift och då prognosstyrningen var avstängd. Då Ecopilot var avstängd var medeltemperaturen 22,1 °C. Under mätperioderna uppmättes en variation som understeg ± 1 °C från medelvärdet för respektive mätperiod. Baserat på resultaten presenterade i detta examensarbete antaganden angående hur stor besparing av värme som Ecopilot ger upphov till revideras. Att jämföra energianvändning före och efter installation av styrsystem såsom Ecopilot kan ge en dålig bild av hur stor del av energibesparingen som orsakats av Ecopilot, speciellt om reglerkurvorna i det gamla systemet var dåligt intrimmade.
54

Kontrollförslag för stabil temperatur och relativ luftfuktighet i konstmuseum : Simuleringsmodell med MPC-kontroll för HVAC-system

Svensson, Anna, Maria January 2022 (has links)
I samarbete med Norconsult och kund ska denna rapport undersöka inomhusklimatet i ett museum och resultera i ett förslag på ett kontrollsystem för Heating, Vetilation and Air conditioning (HVAC) som genererar stabil temperatur och relativ luftfuktighet (RF) inom rekommenderade gränsvärden för konstbevaring. Genom litteraturstudier, fältstudier, dataanalys och skapandet av en simulerad modell av utrymmet, ska ett förslag om lämplig kontrollmetod av HVAC framläggas. Vid test av olika kontrollmetoder, tog sig MPC-kontrollen sig bäst ut. Litteraturstudien innefattar flera studier och rapporter som använt sig av MPC-kontroll för liknande projekt med fördelaktiga resultat. Resultaten av dataanalysen visar att under stor del av loggnings-perioden avvek temperatur och/eller RF från gränsvärdena. I vissa utrymmen var uppemot 99% av de loggade värdena utanför gränsvärdet för antingen temperatur eller RF. Av samtliga sensorsamplingar på museet låg 48,53% av dessa utanför de satta rekommendationerna. Generellt var luften i museet för varm och torr till syftet konstförvaltning. Vid jämförelse av de tre utvecklade MPC-kontrollerna, visar alla varianterna till att generera stabila resultat. Det framarbetade förslaget indikerar på ett energieffektivare kontrollsystem gentemot befintligt. Om simuleringsmodellen av utrymmet visar skilja sig från verkliga förhållanden, förändras dynamiken i systemet, och inställningarna för MPC-kontrollen gäller ej längre utan behövs konfigureras om. Projektets primära mål om att generera ett optimerat systemförslag som kontrollerar parametrarna temperatur RF, anses ha uppnåtts - om än endast i simulerade resultat. Vidare arbete innefattar att verifiera modellen mot befintligt system, och därefter inkludera kostnadsfunktioner till MPC-kontrollen. Efter systemimplementering bör faktiska utfall jämföras med simulerade utfall för att utvärdera modellens precision. / In collaboration with Norconsult and the customer, this report will examine the indoor climate in the museum and result in a proposal for a control system for HVAC that generates stable temperature and RH within recommended values ​​for the preservation of art. A proposal for an appropriate control method of the HVAC shall be presented through literature studies, field studies, data analysis, and the creation of a simulated model of the environment. The MPC control performed best during the testing of different control methods. The literature study includes several studies and papers that use MPC control for similar projects with beneficial results. The results of the data analysis show that during a large part of the logging period, the temperature and/or RH deviated from the limit values. In some areas, up to 99% of the logged values ​​were outside recommendations. Of all sensor samplings at the museum, 48.53% of these were registered outside limit values. In general, the air in the museum was too hot and dry for art preservation. When comparing the three developed MPC controllers, all variants show to generate stable results. The elaborated proposal indicates a more energy-efficient control system compared to the existing one. If the simulation model of the environment turns out to differ from real conditions, the dynamics of the system change , and the settings for the MPC control no longer apply and need to be reconfigured. The project's primary goal of generating an optimized system proposal that controls the temperature and relative humidity is considered to have been achieved - albeit only in simulated results. Further work includes verifying the model against the existing system and including cost functions to the MPC control. After system implementation, actual outcomes should be compared with simulated outcomes to evaluate model precision.
55

Natural Ventilation and Air Infiltration in Large Single‑Zone Buildings : Measurements and Modelling with Reference to Historical Churches

Hayati, Abolfazl January 2017 (has links)
Natural ventilation is the dominating ventilation process in ancient buildings like churches, and also in most domestic buildings in Sweden and in the rest of the world. These buildings are naturally ventilated via air infiltration and airing. Air infiltration is the airflow through adventitious leakages in the building envelope, while airing is the intentional air exchange through large openings like windows and doors. Airing can in turn be performed either as single-sided (one opening) or as cross flow ventilation (two or more openings located on different walls). The total air exchange affects heating energy and indoor air quality. In churches, deposition of airborne particles causes gradual soiling of indoor surfaces, including paintings and other pieces of art. Significant amounts of particles are emitted from visitors and from candles, incense, etc. Temporary airing is likely to reduce this problem, and it can also be used to adjust the indoor temperature. The present study investigates mechanisms and prediction models regarding air infiltration and open-door airing by means of field measurements, experiments in wind tunnel and computer modelling. In natural ventilation, both air infiltration and airing share the same driving forces, i.e. wind and buoyancy (indoor-outdoor temperature differences). Both forces turn out to be difficult to predict, especially wind induced flows and the combination of buoyancy and wind. In the first part of the present study, two of the most established models for predicting air infiltration rate in buildings were evaluated against measurements in three historical stone churches in Sweden. A correction factor of 0.8 is introduced to adjust one of the studied models (which yielded better predictions) for fitting the large single zones like churches. Based on field investigation and IR-thermography inspections, a detailed numerical model was developed for prediction of air infiltration, where input data included assessed level of the neutral pressure level (NPL). The model functionality was validated against measurements in one of the case studies, indicating reasonable prediction capability. It is suggested that this model is further developed by including a more systematic calibration system for more building types and with different weather conditions. Regarding airing, both single-sided and cross flow rates through the porches of various church buildings were measured with tracer gas method, as well as through direct measurements of the air velocity in a porch opening. Measurement results were compared with predictions attained from four previously developed models for single‑sided ventilation. Models that include terms for wind turbulence were found to yield somewhat better predictions. According to the performed measurements, the magnitude of one hour single-sided open-door airing in a church typically yields around 50% air exchange, indicating that this is a workable ventilation method, also for such large building volumes. A practical kind of diagram to facilitate estimation of suitable airing period is presented. The ability of the IDA Indoor Climate and Energy (IDA-ICE) computer program to predict airing rates was examined by comparing with field measurements in a church. The programs’ predictions of single-sided airflows through an open door of the church were of the same magnitude as the measured ones; however, the effect of wind direction was not well captured by the program, indicating a development potential. Finally, wind driven air flows through porch type openings of a church model were studied in a wind tunnel, where the airing rates were measured by tracer gas. At single-sided airing, a higher flow rate was observed at higher wind turbulence and when the opening was on the windward side of the building, in agreement with field measurements. Further, the airing rate was on the order of 15 times higher at cross flow than at single-sided airing. Realization of cross flow thus seems highly recommendable for enhanced airing. Calibration constants for a simple equation for wind driven flow through porches are presented. The measurements also indicate that advection through turbulence is a more important airing mechanism than pumping.   The present work adds knowledge particularly to the issues of air infiltration and airing through doors, in large single zones. The results can be applicable also to other kinds of large single-zone buildings, like industry halls, atriums and sports halls. / Naturlig ventilation är den dominerande ventilationsprocessen i äldre byggnader såsom kyrkor, och även i de flesta småhus i Sverige och övriga delar av världen. Luftinfiltration och vädring utgör viktiga komponenter i naturlig ventilation, där luftinfiltration är luftflöde genom oavsiktliga läckage i byggnadsskalet, medan vädring är avsiktligt luftutbyte genom stora öppningar såsom fönster och dörrar/portar. Vädring kan i sin tur ske ensidigt (genom en öppning) eller som tvärdrag (genom två eller flera öppningar belägna på olika ytterväggar). Det totala luftutbytet påverkar värmeförluster och inomhusluftens kvalité. I kyrkor orsakar avsättning av luftpartiklar en gradvis nedsmutsning av invändiga ytor, inklusive väggmålningar och andra konstföremål. Betydande mängder partiklar avges från besökare, tända ljus, rökelse, o.d. Tillfällig vädring kan minska detta problem, men även användas för att justera innetemperaturen. Föreliggande studie analyserar mekanismer och predikteringsmodeller gällande luftinfiltration och dörrvädring genom fältmätningar, vindtunnelförsök och datorsimuleringar. Luftinfiltration och vädring har samma drivkrafter, d.v.s. vind och termik (inne‑ute temperaturskillnader). Båda dessa drivkrafter är svåra att predicera, särskilt vindinducerade flöden och kombinationen av termik och vind. Två av de mest etablerade modellerna för luftinfiltrationsprediktering i byggnader har utvärderats via mätningar i tre kulturhistoriska stenkyrkor i Sverige. En korrigeringsfaktor av 0,8 föreslås för bättre prediktion av den ena modellen (som gav bäst resultat) gällande höga en-zonsbyggnader såsom kyrkor. En detaljerad numerisk modell är utvecklad för luftinfiltrationsprediktering, där indata baseras på fältundersökningar, inkl. IR-termografering och uppmätt av neutrala tryckplanet (NPL). Modellens funktionalitet har validerats via mätningar i en av fallstudierna och pekar på tämligen god prediktionsprestanda. Vidare utveckling av modellen föreslås, inkl. ett mer systematiskt kalibreringssystem, för olika typer av byggnader och väderförhållanden. Gällande vädring mättes både ensidigt flöde och tvärdrag genom portar i olika kyrkobyggnader med hjälp av spårgas samt direkta lufthastighetsmätningar i portöppning. Mätresultaten jämfördes med erhållna prediktioner från fyra tidigare utvecklade modeller för ensidig ventilation. De modeller som tog hänsyn till vindturbulens gav något bättre resultat. Enligt utförda mätningar medför en timmes ensidig portvädring i en kyrka cirka 50 % luftutbyte, vilket indikerar att detta är en tillämpbar ventilationsmetod, även för så pass stora byggnadsvolymer. Ett särskilt vädringsdiagram presenteras, som syftar till att underlätta uppskattning av erforderlig vädringsperiod. Vidare studerades predikteringsprestanda hos IDA Indoor Climate and Energy (IDA-ICE) simuleringsprogram avseende vädring, där simuleringsdata jämfördes med fältmätningar i en kyrka. Programmets prediktion av ensidigt luftflöde genom en öppen kyrkport var av samma storlekordning som det uppmäta; dock klarade programmet inte av att hantera inverkan av vindriktning så väl, vilket pekar på en utvecklingspotential. Avslutningsvis undersöktes vinddrivet flöde igenom portöppningar i en kyrkmodell i vindtunnel, där luftomsättningen mättes med hjälp av spårgasmetoden. Vid ensidig vädring observerades högre flöde vid högre vindturbulens och när öppningen var på vindsidan av byggnaden, i överensstämmelse med fältmätningarna. Dessutom var vädringsflödet vid tvärdrag i storleksordningen 15 högre än det vid ensidig vädring. Det verkar alltså som att man kan öka vädringstakten avsevärt om man kan åstadkomma tvärdrag. Kalibreringskonstanter presenteras också för en enkel ekvation för vinddrivet flöde genom portar. Vindtunnelstudien indikerar vidare att advektion genom turbulens är en viktigare vädringsmekanism än pumpning. Föreliggande arbete bidrar med kunskap speciellt kring luftinfiltration och vädring genom portar i höga en-zonsbyggnader. Resultaten kan även vara tillämpliga på andra typer av höga en-zonsbyggnader såsom industrihallar, atrier/ljusgårdar och idrottshallar. / Church project
56

The environmental and social impact from digitization in buildings : A case study of the transformation and current conditions on the University hospital of Northern Sweden

Melén, Matilda, Wenhov, Alma January 2022 (has links)
To improve sustainability, social, environmental and economic aspects needs to be considered. The most optimal result appears when all three aspects are balanced equally, this is however often overseen by private investors, who focuses only on reaching economic sustainability at the expense of social and environmental sustainability. Building digitization is one way to potentially improve the sustainability of a building socially, environmentally and economically. Focusing on the aspects that often are neglected, this thesis aims to investigate if digitizing a building improves social and environmental sustainability. The investigation is made by evaluating the implementation of a digital building automation tool from selected social and environmental sustainability criteria at the University hospital of Northern Sweden. This by performing an interview survey with the maintenance organisation and the tenants in the building, as well as performing CO2-e calculations on emissions connected to energy usage, transportation and production of HVAC-products. The evaluation indicated that the implementation had resulted in improved sustainability in the studied building, both socially and environmentally. Showing that digitizing a building improves social and environmental sustainability. The social sustainability had been positively affected from increased efficiency and effectiveness of the maintenance work in the building and improved well-being of the maintenance staff. However, the tenants were not completely satisfied when asked if reported errors were being solved, but on the other hand had the maintenance organisation experienced an improvement in satisfaction among the tenants since the implementation of the digital building automation tool. Furthermore, the tenants were generally more satisfied than dissatisfied with the indoor climate, except for experienced low temperatures in the winter and dry air. The environmental sustainability had been improved from a reduction in emitted CO2-e, generated from less energy usage and minimized transportation connected to maintenance operations. Furthermore, an estimation on increased technical lifetime of HVAC-products demonstrated on a potential further reduction in emitted CO2-e during the building's whole life span. Finally, the evaluation identified two combined effects between social and environmental sustainability. First, the increased efficiency and effectiveness of the maintenance work was one direct factor for the decrease in CO2-e emissions connected to transportation. Second, the tenants in the building expressed that they would feel prouder of their choice of employer if their employer focused more on reducing their climate impact, which motivates to work with environmental sustainability to achieve satisfaction and moreover an improved social sustainability.  The results of this case study indicate that digital building automation improves the social and environmental sustainability of a building, strengthening the statement on potential sustainability improvements from building digitization. For property owners wanting to increase their building's sustainability, digital building automation is therefore a proposed course of action. However, the performance on sustainability and the balance between the different aspects should continuously be evaluated, as the study showed that further improvements on the social and environmental sustainability still could be made. Property owners working towards an improved sustainability through digitization will both see long term positive effects on people's health, as well as help fulfilling the climate goals in the Paris agreement, resulting in a more sustainable world for present and future generations. / För att skapa en bättre hållbarhet måste hänsyn tas till både den sociala, miljömässiga samt den ekonomiska aspekten. Fokuset på dessa tre aspekter bör balanseras lika för att uppnå optimal hållbarhet, dock efterföljs detta inte vanligtvis av privata investerare som ofta endast fokuserar på att uppnå ekonomisk hållbarhet på bekostnad av den sociala- och miljömässiga hållbarheten. En byggnads hållbarhet kan potentiellt förbättras genom digitalisering av byggnaden, vilket kan förbättra den sociala, miljömässiga och ekonomiska hållbarheten. Genom att fokusera på de aspekter som ofta blir nedprioriterade undersöker denna studie om den sociala och miljömässiga hållbarheten i en byggnad ökar vid digitalisering. Detta genom att utvärdera implementeringen av ett digitalt verktyg på Norrlands Universitetssjukhus från några utvalda kriterier för social och miljömässig hållbarhet. Den sociala hållbarheten utvärderas med hjälp av en intervjustudie med underhållspersonalen och hyresgästerna i byggnaden, medan den miljömässiga hållbarheten utvärderades genom att beräkna CO2-e utsläpp kopplade till energianvändning, transporter samt produktionen av HVAC-produkter. Utvärderingen indikerade att implementeringen hade resulterat i en ökad social och miljömässig hållbarhet i byggnaden, vilket visar att en byggnads sociala och miljömässiga hållbarhet kan förbättras genom digitalisering. Den sociala hållbarheten hade ökat på grund av en ökad effektivitet i underhållsarbetet samt ett förbättrat välmående hos underhållspersonalen. Dock visade undersökningen att hyresgästerna i byggnaden inte var helt nöjda med arbetet kring felanmälningar, underhållsorganisationen hade dock upplevt att hyresgästerna var nöjdare efter implementeringen av det digitala verktyget än de var innan. Hyresgästerna var också mer nöjda än missnöjda med inomhusklimatet, förutom att de upplevde låg inomhustemperatur på vintern och att luften var torr. Den miljömässiga hållbarheten hade förbättrats genom en minskning av CO2-e utsläpp från minskad energianvändning och minskade transporter kopplade till underhållsarbetet. Den estimerade ökningen av den tekniska livslängden på HVAC-produkter visade också på potentiella minskningar av CO2-utsläpp under byggnadens hela livslängd. Denna studie identifierade också två kombinerade effekter mellan social- och miljömässig hållbarhet. Den första var att genom ökad effektivitet i arbetet för underhållspersonalen så minskade även CO2-e utsläppen från transporterna. Den andra var att hyresgästerna i byggnaden uttryckte att de skulle känna sig stoltare över sitt val av arbetsgivare om deras arbetsgivare fokuserade mer på att minska sin klimatpåverkan, vilket motiverar att arbeta med miljömässighållbarhet för att uppnå ökad tillfredsställelse hos hyresgästerna och därav ökad social hållbarhet.  Resultaten från denna fallstudie indikerar att digital fastighetsautomation förbättrar den sociala och miljömässiga hållbarheten av en byggnad, vilket styrker argumentet att en byggnads hållbarhet potentiellt kan förbättras genom digitalisering. För fastighetsägare som vill öka en byggnads hållbarhet är digital fastighetsautomation därför rekommenderat. Hållbarheten samt balansen mellan de olika hållbarhetsaspekterna behöver däremot kontinuerligt utvärderas, eftersom denna studie har visat att den sociala- och miljömässigahållbarheten fortfarande kan förbättras. Fastighetsägare som arbetar med att öka hållbarheten i byggnader genom digitalisering kommer uppleva långvariga positiva effekter för människors hälsa samt så kommer de bidra till att uppnå klimatmålen i Parisavtalet. Detta resulterar i en mer hållbar värld för nutida och framtida generationer.

Page generated in 0.0555 seconds