• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 2
  • 2
  • Tagged with
  • 7
  • 7
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Värmeisoleringsmaterial i Sverige : En jämförelse av glasull, stenull samt förnyelsebara material

Berglund, Johanna, Björkman, Carolina January 2021 (has links)
I Sverige ska man följa Plan- och bygglagen samt Boverkets byggregler vid ny- och ombyggnation, där både krav och regler finns för värmeisolering. Ytterväggarna är en stor del av klimatskärmen där värmeisoleringsmaterialet påverkar den värmemängd som går förlorad. Beroende på vilket värmeisoleringsmaterial man väljer, har det olika för- och nackdelar. Av denna anledning är syftet att studera olika värmeisoleringsmaterial som används i Sverige idag och hur materialen skiljer sig åt. En enkätundersökning mejlades ut till entreprenörer och återförsäljare för att ta reda på vilka värmeisoleringsmaterial som vanligast används i Sverige. Svarsfrekvensen blev låg, men de inkommande svaren bidrog till ett fortsatt arbete. Nio produkter inom kategorierna stenull, glasull och förnyelsebar isolering studerades vidare. Produkterna jämfördes utifrån tillverkning, miljöpåverkan, tekniska egenskaper, hanterbarhet, avfallshantering och kostnad. Varje aspekt tilldelades en bedömning som var kopplad till en viss poäng. Resultatet blev en tabell med totalpoäng där den produkt med högst poäng anses som den mest fördelaktiga. Vid en jämförelse med ett poängsystem, kan resultatet variera beroende på produktens egenskaper, valet av aspekter samt hur man väljer att poängsätta vid bedömning. / In Sweden, you must follow the Planning and Building Act and Building and planning regulations for new- and reconstruction, where both requirements and rules are available for thermal insulation. Exterior walls are a large part of the climate screen where the thermal insulation material affects the amount of heat that is lost. Depending on which thermal insulation material you choose, it has different advantages and disadvantages. For this reason, the purpose is to study different thermal insulation materials used in Sweden today and how the materials may differ from each other.  A survey was emailed to contractors and reseller to find out which thermal insulation materials are most commonly used in Sweden. The response rate was low, but the incoming responses contributed to continued work. Nine products in the categories rock wool, glass wool and renewable insulation were further studied. The products were compared based on manufacturing, environmental impact, technical properties, manageability, waste management and cost. Each aspect was awarded an assessment that was linked to a specific score. The final result was a table with total points for each product and the product with the highest score is considered the most advantageous. When you have a comparison with a points system the result can vary depending on the product's properties, the choice of aspects and how the score is set in the assessment.
2

Komplexní zateplovací systém pro vyšší teploty s využitím druhotných surovin / Complete insulation system for high temperature using secondary raw materials

Mészárosová, Lenka January 2017 (has links)
This work deals with the development of new types of insulating materials for use in the higher temperature. The area of application of these insulation materials is especially industrial chimneys, where the exhaust gases achieves 85 to 200 °C, furthermore it is industrial boilers and furnaces with surface temperature to 500 °C. In the introduction is presented the current knowledge in the field of insulating materials in the Czech Republic and in the world. Then the work is dealing with proposal of possible raw materials and suitable formula. According to purpose of use is the work divided into two parts – high temperature insulation for simple and for complicated shapes conditions. The sub-sections are divided to different possibilities of performance. The aim was, based on the scientific expertise of other authors in the world, design a new insulation system and redound to deepening scientific knowledge in the area of lightweight materials on the silica basis and to the extension of the offer of new products in building and industrial practice.
3

Increasing Effective Thermal Resistance of Building Envelope's Insulation Using Polyurethane Foam Incorporated with Phase Change Material

Houl, Yassine 05 1900 (has links)
Incorporating insulation material with phase change materials (PCMs) could help enhance the insulation capability for further building energy savings by reducing the HVAC loadings. During the phase change process between the solid and liquid states, heat is being absorbed or released by PCMs depending on the surrounding temperature. This research explores the benefits of a polyurethane (PU)-PCM composite insulation material through infiltrating paraffin wax as PCM into PU open cell foam. The new PU-PCM composite provides extra shielding from the exterior hot temperatures for buildings. Through this study, it was demonstrated that PU-PCM composite insulation could potentially help building energy savings through reducing the loads on the HVAC systems based on the building energy modeling using EnergyPlus. The Zero Energy Lab (ZØE) at the University of North Texas was modeled and studied in the EnergyPlus. It is a detached building with all wall facades exposed to the ambient. It was determined that the new PU-PCM insulation material could provide 14% total energy saving per year and reduce the electricity use due to cooling only by around 30%.
4

Optimering av en ytterväggsprodukt : En undersökning av alternativa isoleringsmaterial / Optimization of an external wall product : An investigation of alternative insulation materials

Karlsson, Sofie, Geijersson, Agnes January 2018 (has links)
AquaVillas CasaBona väggsystem innehåller i dagsläget isoleringsmaterialet EPS, vilket har visat svagheter vid brand. Målet med denna studie var att föreslå ett alternativt isoleringsmaterial till EPS med hänsyn till brand, energianvändning och U-värde, samt energiåtgång och koldioxidutsläpp vid tillverkning. Syftet var att det föreslagna alternativa isoleringsmaterialet skall kunna användas av tillverkare i väggprodukter som ett alternativ till EPS. I denna studie undersöktes fyra olika isoleringsmaterial genom kritisk granskning av vetenskapliga artiklar och litteratur, samt genom fältstudie och beräkningar i energiberäkningsprogrammet VIP-energy. De isoleringsmaterial som undersöktes var expanderad polystyren, polyuretan, polyisocyanurat och stenull. Resultaten visade att EPS, PUR och PIR är avsevärt sämre ur brandsynpunkt än stenull. Vid tillverkning av de olika isoleringsmaterialen fick EPS bäst resultat när det gäller koldioxidutsläpp. För energiåtgång vid tillverkning fick EPS bäst resultat då isoleringsskiktet i det undersökta väggsystemet var 200 mm tjockt, men då utgångspunkten istället var att väggen skulle ha ett U-värde på 0,112 W/m2K, fick stenull bäst resultat i denna kategori. PUR och PIR fick sämst resultat gällande både energiåtgång och koldioxidutsläpp vid tillverkning. Stenull gav väggen den bästa energianvändningen men samtliga material klarade kraven i Boverkets Byggregler. Vid sammanvägning av samtliga undersökta egenskaper för de olika isoleringsmaterialen anses det mest lämpliga materialet för en vägg vara stenull. / The AquaVilla CasaBona wall system currently contains the insulation material EPS, which has shown weaknesses while exposed to fire. The aim for this study was to suggest an alternative insulation material to EPS regarding fire, energy use and U-vale as well as energy use and carbon dioxide emissions for manufacturing. The purpose was that the suggested alternative insulation material should be able to be used by manufacturers in wall products as an alternative to EPS. In this study, four different insulation materials were examined by critically reviewing scientific articles and literature, as well as field studies and calculations with the energy calculation program VIP-energy. The insulation materials investigated were expanded polystyrene, polyurethane, polyisocyanurate and rockwool. The findings showed that EPS, PUR and PIR were not nearly as good as rockwool regarding fire. When manufacturing the various insulation materials, EPS gives the best results in terms of carbon dioxide emissions. EPS gives the best results regarding energy use for manufacturing when the insulation layer in the investigated wall system was 200 mm thick, but when the wall was given a U-value of 0,112 W/m2K, rockwool got the best results in this category. PUR and PIR gave the worst results regarding both energy use and carbon dioxide emissions at manufacturing. Rockwool generated the best results regarding energy use, but all of the materials met the requirements from Boverkets Byggregler. When comparing all the investigated characteristics of the various insulation materials, the most suitable material for an external wall was considered to be rockwool.
5

Sustainable Ecofriendly Insulation Foams for Disaster Relief Housing

Chitela, Yuvaraj Reddy 05 1900 (has links)
Natural disasters are affecting a significant number of people around the world. Sheltering is the first step in post-disaster activities towards the normalization of the affected people's lives. Temporary housing is being used in these cases until the construction of permanent houses are done. Disposal of temporary housing after use is leading to a significant environmental impact because most of them are filled with thermally insulative polymer foams that do not degrade in a short period. To reduce these problems this work proposes to use foams made with compostable thermoplastic polylactic acid (PLA) and degradable kenaf core as filler materials; these foams are made using CO2 as blowing agent for insulation purposes. Foams with PLA and 5%, 10% and 15% kenaf core were tested. Different properties and their relations were examined using differential scanning calorimetry (DSC), thermal conductivity, mechanical properties, scanning electron microscopy (SEM), x-ray μ-computed tomography (μ-CT) and building energy simulations were done using Energy Plus by NREL. The results show that mechanical properties are reduced with the introduction of kenaf core reinforcement while thermal conductivity display a noticeable improvement.
6

The Impact of Insulation Materials on a Climate Declaration : A Study of a Swedish Preschool

Hallkvist, Isabelle, Nilsson, Elin January 2021 (has links)
To reach the net-zero carbon goal by 2045, the Swedish government want to push the building and construction sector to lower their greenhouse gas emissions. This push is performed by implementing a law requiring building developers to perform a climate declaration over greenhouse gas emissions, to receive a building’s final clearance. The climate declaration is limited to only include emissions from material extraction until completed building. However, there is a varying knowledge level in the industry regarding how to perform a climate declaration as well as how different materials impact the result. Therefore, this study aims to bring clarity concerning the topic, by investigating where the major and minor climate impacts occur in a building process. Additionally, the impact of different insulations materials and how they influence the result of a climate declaration is studied. To answer the research questions, a climate declaration is performed on a Swedish preschool. The insulation material in the building is altered between glass wool, stone wool, cellulose fibre, foam glass, and polystyrene insulation in different scenarios to see how it impacts the result. The stone wool scenarios use both carbon neutral and non-carbon neutral insulation. Cellulose fibre uses both loose wool with data from an EPD and board insulation with data from Boverket’s climate database in the scenarios. The major climate impact derives from the product stage (A1–A3), meaning material selection have a significant impact on the climate declaration result. The building element with the highest climate impact is the inner walls followed by the foundation, while the floor construction, roof and outer walls have the lowest climate impact. On a material level, plaster board, building plywood and concrete have the highest climate impact in the reference building. The cedar panel have the lowest climate impact and is the only carbon negative material in the reference building. However, this is due to different assumptions made in the climate impact data concerning the binding of carbon in organic materials. The results showed that the insulation material with the highest climate impact is non-carbon neutral stone wool that is 16 % higher than the original construction with glass wool, while loose cellulose wool has the lowest climate impact. The climate impact from the scenario with non-carbon neutral stone wool in the wall and roof construction is 33 % higher compared to the corresponding loose cellulose wool scenario. The scenario with the lowest climate impact, with loose cellulose wool, is approximately 13 % lower than the corresponding glass wool scenario. The carbon neutral stone wool scenario has a similar result to glass wool. Foam glass has a 9.5 % higher climate impact compared to polystyrene insulation in the foundation. Regarding the selection of insulation material, it influences the climate declaration by changing the climate impact. The influence derives from a combination of climate impact per unit and material quantity used in the building. The material quantity is partly dependant on the thermal conductivity (λ-value) of the insulation material. The climate declaration shows a limited view of a building’s environmental impact for a limited part of its lifecycle. Therefore, we would recommend additional lifecycle stages and environmental impacts to be part of the climate declaration in the future, as a means to avoid suboptimization and unintentional problem shifting. / För att nå klimatneutralitetsmålet 2045 vill den svenska regeringen driva bygg- och fastighetssektorn till att sänka sina växthusgasutsläpp. Denna insats utförs genom att införa en lag som kräver att byggherrar utför en klimatdeklaration över växthusgasutsläpp för att få ett slutbesked för byggnaden. Klimatdeklarationen är begränsad till att endast omfatta utsläpp från materialutvinning fram till färdig byggnad. Det finns dock en varierande kunskapsnivå i branschen om hur en klimatdeklaration utförs samt hur olika material påverkar resultatet. Därför syftar denna studie till att ge klarhet angående ämnet genom att undersöka var de större och mindre inflytandena på klimatpåverkan förekommer i en byggprocess. Dessutom studeras effekterna av olika isoleringsmaterial och hur de påverkar resultatet av en klimatdeklaration. För att besvara frågeställningarna utförs en klimatdeklaration på en svensk förskola. Isoleringsmaterialet i byggnaden ändras mellan glasull, stenull, cellulosafiber, skumglas och cellplast i olika scenarier för att se hur det påverkar resultatet. I stenullscenarierna används både koldioxidneutral och icke-koldioxidneutral isolering. Cellulosafibrer använder både lösull med data från en EPD och skivisolering med data från Boverkets klimatdatabas i scenarierna. Den största klimatpåverkan kommer från produktstadiet (A1–A3), vilket innebär att materialvalet har en betydande inverkan på klimatdeklarationsresultatet. Byggnadselementet med störst klimatpåverkan är innerväggarna följt av grunden, medan bjälklaget, taket och ytterväggarna har lägst klimatpåverkan. På materialnivå har gipsskivor, plywood och betong den högsta klimatpåverkan i referensbyggnaden. Cederpanelen har lägst klimatpåverkan och är det enda koldioxidnegativa materialet i referensbyggnaden. Detta beror dock på olika antaganden i klimatpåverkan angående bindningen av kol i organiska material. Resultaten visade att isoleringsmaterialet med den högsta klimatpåverkan är icke-koldioxidneutral stenull, som är 16 % högre än originalkonstruktionen med glasull, medan lös cellulosaull har lägst klimatpåverkan. Klimatpåverkan från scenariot med icke koldioxidneutral stenull i vägg- och takkonstruktion är 33 % högre jämfört med motsvarande scenario med lös cellulosaull. Scenariot med lägst klimatpåverkan, med lös cellulosaull, är cirka 13 % lägre än motsvarande glasullscenario. Det koldioxidneutrala stenullscenariot har ett liknande resultat som glasull. Skumglas har 9,5 % högre klimatpåverkan jämfört med cellplasten i grunden. När det gäller valet av isoleringsmaterial påverkar det klimatdeklarationen genom att förändra klimatpåverkan. Påverkan härstammar från en kombination av klimatpåverkan per enhet och mängden material som används i byggnaden. Mängden material beror delvis på isoleringsmaterialets värmekonduktivitet (λ-värde). Klimatdeklarationen visar en begränsad bild av en byggnads miljöpåverkan under en begränsad del av dess livscykel. Därför rekommenderar vi att ytterligare livscykelstadier och miljöindikatorer ingår i klimatdeklarationen i framtiden, för att undvika suboptimeringar och oavsiktliga problembyten.
7

Izolační systémy elektrických strojů malého a nízkého napětí / Low-voltage and low-voltage electrical machines insulating systems

Procházka, Jan January 2019 (has links)
This thesis describes properties of windings of electric rotating machines and their insulation systems. There are winding and insulation low voltage machines tests listed with their procedures and criteria. Further it deals with coordination methodology and the last part contains execution and results assessment of tests conducted on stator samples.

Page generated in 0.1228 seconds