Spelling suggestions: "subject:"mono."" "subject:"sono.""
291 |
Monitorização ambulatorial da pressão arterial em portadores de doença pulmonar obstrutiva crônica com dessaturação no sono / Ambulatory Blood Pressure Monitoring in Patients with Chronic Obstructive Pulmonary Disease with Sleep DesaturationAidar, Neila Anders January 2008 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Medicina, 2008. / Submitted by wesley oliveira leite (leite.wesley@yahoo.com.br) on 2009-09-18T14:00:17Z
No. of bitstreams: 1
2008_NeilaAndersAidav.pdf: 736201 bytes, checksum: 00033407f75dd6f15eb46ab3a5c04005 (MD5) / Approved for entry into archive by Luanna Maia(luanna@bce.unb.br) on 2010-01-26T14:08:44Z (GMT) No. of bitstreams: 1
2008_NeilaAndersAidav.pdf: 736201 bytes, checksum: 00033407f75dd6f15eb46ab3a5c04005 (MD5) / Made available in DSpace on 2010-01-26T14:08:44Z (GMT). No. of bitstreams: 1
2008_NeilaAndersAidav.pdf: 736201 bytes, checksum: 00033407f75dd6f15eb46ab3a5c04005 (MD5)
Previous issue date: 2008 / Introdução: A hipoxemia no período de sono pode alterar a pressão arterial por mecanismo de ativação simpática. Poucos estudos mostram as variações da pressão arterial em pacientes portadores de doença pulmonar obstrutiva crônica (DPOC) e dessaturação no sono não causada por apnéia. Objetivos: Analisar variações da pressão arterial em pacientes com doença pulmonar obstrutiva crônica e dessaturação no sono, não causada por apnéia. Métodos: Treze pacientes com DPOC foram submetidos à espirometria, gasometria arterial, polissonografia e MAPA de 24 horas para avaliar as variações pressóricas. Quatorze pacientes não portadores de DPOC ( grupo controle), foram submetidos à espirometria, oximetria diurna, noturna e monitorização ambulatorial da pressão arterial de 24 horas. As análises da pressão arterial foram feitas tanto na vigília quanto no sono. Os dois grupos foram constituídos por pacientes sem antecedentes hipertensivos e não portadores de hipertensão de consultório. Resultados: Os dois grupos eram semelhantes em relação à idade, altura, peso e índice de massa corporal. Houve diferença significativa (p < 0,05) entre os valores pressóricos nos períodos de descenso do sono, vigília, sono, 24 horas e matutino. Observou-se descenso do sono atenuado no grupo DPOC: 4,38% e 6,0%, respectivamente para valores sistólicos e diastólicos, enquanto o grupo controle apresentou descenso fisiológico de 14,0 % e 16,21%. As médias sistólicas em vigília foram maiores no grupo DPOC do que no grupo controle: PAS= 132,69±12,61 mmHg no grupo DPOC e PAS=120,29±10,20 mmHg no grupo controle(P=0,009). Em vigília não foram observadas diferenças significativas nas médias de PAD. No período de sono, os valores de PAS se mostraram maiores no grupo DPOC com valores médios de; PAS= 126,46±10,76 mmHg e PAD= 70,77±6,92 mmHg.No grupo controle; médias de PAS=103,86±13,6 mmHg(P=0,0001) e PAD= 62,14±10,07 mmHg (P=0,016). Os valores médios aferidos em 24 horas demonstraram diferença significativa apenas em PAS (P=0,002) entre os dois grupos; com PAS = 131,15±11,53 mmHg e PAD= 74,62±7,30 mmHg.No grupo controle as médias de 24horas foram; PAS=116,79±10,18 mmHg e PAD= 71,00±10,17 mmHg . No período matutino, os valores médios de PAS e PAD foram estatisticamente maiores no grupo DPOC, com PAS=138,85±13,10mmHg e PAD=81,58±10,78mmHg.No grupo controle PAS=113,93±9,35 mmHg(P=0,0001) e PAD=67,36±11,53 mmHg( P= 0,004) . Conclusões: Os resultados da pressão arterial sistólica e diastólica se mostraram maiores no grupo DPOC do que no grupo controle. A significância desta afirmação ocorreu em todos os períodos aferidos, exceto em níveis diastólicos na vigília, valores máximos de PAD no sono e média de PAD nas 24horas. Neste estudo, pode-se concluir, então, que o grupo portador de DPOC com dessaturação no sono possui níveis de pressão arterial maiores que o grupo controle. _______________________________________________________________________________ ABSTRACT / Introduction: The hypoxemia during the sleep period can, by a sympathetic activation mechanism, change the blood pressure. Few studies show the alterations of the blood pressure, during the sleep period, in chronic obstructive pulmonary disease patients that do not have sleep apnea, but do desaturate during this period. Objective: To analyze the arterial pressure variation in chronic obstructive pulmonary diseased patients that have nocturnal desaturation, not caused by apnea. Methods: Thirteen chronic obstructive pulmonary diseased patients were submitted to spirometry, arterial gasometry, polysomnography and a 24-hour Ambulatory Blood Pressure Monitoring (ABPM) to evaluate the pressure variations. Fourteen patients who do not have the chronic obstructive pulmonary disease were submitted to spirometry, to oxymetry and to a 24-hour arterial pressure ambulatory monitoring. The arterial pressure analyses were made both in vigil and in sleep time. Both groups consisted of patients without hypertensive antecedents. Results: The two groups were similar in terms of age, height, weight and body mass index. There was a significant difference (p < 0,05) among the pressure parameters in the vigil, sleep, 24-hour and sleep “dipper” periods. There was a drop in the sleep “dipper” in COPD group: 4.38% and 6.0% respectively for systolic and diastolic values, while the control group showed physiological sleep “dipper” of 14.0% and 16.21%.The average systolic in vigil were higher in COPD group than in the control group: SBP = 132.69 ± 12.61 mmHg in COPD group and SBP= 120.29 ± 10.20 mmHg in the control group, with P = 0009. There were no significant differences in mean DBP in vigil. During sleep period, the average SBP were higher in COPD group than in the control group, with values of SBP= 126.46 ± 10.76 mmHg and DBP= 70.77 ± 6.92 mmHg in COPD group and SBP = 103.86 ± 13.6 mmHg and DBP= 62.14 mm Hg in the control group with P= 0.0001 in SBP and P= 0016 in DBP. The average values measured in 24 hours showed significant difference only in SBP (P = 0002) among the two groups: COPD group with SBP= 131.15 ± 11.53 mm Hg and DBP= 74.62 ± 7.30 mmHg, and control group with averages of 116.79 ± 10.18 mmHg in SBP and 71.00 ± 10.17 mmHg in diastolic blood pressure. In the morning period, the average values of SBP and DBP were statistically higher in the COPD group, as SBP = 138.85 ± 13.10 mmHg and DBP = 81.58 ± 10.78 mmHg in COPD group and SBP = 113.93 ± 9.35 mmHg and DBP = 67.36 ± 11.53 mmHg in the control group (P = 0.0001 for SBP and P = 0.004 for DBP). Conclusion: The systolic and diastolic arterial pressure results were higher in the COPD group than in the control group. The significance of this statement has occurred during all the surveyed periods, except in the vigil and in the 24 hours for the diastolic pressure levels. In this study, it can be concluded that the COPD carrier group with nocturnal desaturation has arterial pressure levels higher than the control group.
|
292 |
Perturbações do sono em doentes com limitação crônica ao fluxo aéreoMarchiori, Roseane Cardoso January 1992 (has links)
Este estudo foi realizado prospectivamente, para descrever o quadro polissonográflco de pacientes com limitação crônica ao fluxo aéreo e para testar a hipótese de que a qualidade do sono destes pacientes é semelhante à de pessoas sem pneumopatia mas com queixas de sono perturbado. Foi criado um índice de qualidade do sono, composto por escores atribuídos a cinco variáveis polissonográflcas, totalizando de zero a dez pontos. Foram estudados 22 pacientes consecutivos (16 homens, sete mulheres), portadores de limitação crônica ao fluxo aéreo, com sintomas há mais de três anos, idade mínima de 18 anos. O grupo controle foi composto por 11 pacientes (oito homens, três mulheres), que procuraram o Laboratório do Sono da Santa Casa de Misericórdia, para avaliação de distúrbio do sono. Os pacientes com limitação crônica ao fluxo aéreo tinham idade (média ± um desvio padrão) de 54 ± 16 anos, com variação de 21 a 73 anos: a altura foi de 1,68 ± 0,07 metro, com variação de 1,68 a 1,84 metro: o peso foi de 71 ± 14 quilogramas, com variação de 54 a 108 quilogramas e o índice de massa corporal foi 25,0 ± 3,6 Kg / m2, com variação de 20,4 a 34,0 Kg/m2. A relação VEF1 / CVF foi, em média, 47 ± 18 %, com variação de 24 a 67%. O volume expiratório forçado em um segundo foi, em média, 1,30 ± O,71 litro, com variação de 0,39 a 3,43 litro, o que correspondeu a 39 ± 17 % do previsto, com variação de 12 a 69%. Houve 39 ± 27 % de melhora do VEF1, 15 minutos após o uso de broncodUatador, com variação de 14 a 120 %. Nos pacientes em estudo, a dificuldade em iniciar o sono esteve associada à dificuldade em manter o sono ( p O,Ol), à hipoxemia em vigília (p=0,04), bem como à presença de disritmias respiratórias (p=0,006). A presença de disritmias respiratórias associou-se, também, a uma latência ao sono REM prolongada. A menor percentagem de sono de ondas lentas correlacionou-se com maior número de movimentos corpóreos (p=0,02) e maior número de despertares com mais de cinco minutos (P= 0,03). O índice de qualidade do sono correlacionou-se com a eficiência do sono (p= 0,06) e com a dessaturação durante o sono (p=0,006). Não se observou correlação entre a saturação máxima de oxigênio arterial e o índice de qualidade do sono (p= 0,30). Assim, é difícil prever, pela oximetria da vigília, a qualidade do sono de um paciente com limitação crônica ao fluxo aéreo. Dois dos 22 pacientes com limitação crônica ao fluxo aéreo tiveram o diagnóstico polissonográfico de síndrome da apnéia do sono. Os grupos diferiram quanto aos dados de saturação máxima, média e mínima de oxigênio, sendo que os pacientes com limitação crônica ao fluxo aéreo apresentaram valores inferiores aos dos controles. Houve diferença, também, quanto aos dados de índice de qualidade do sono e percentagem de estágio 1, sendo que os pacientes com limitação crônica ao fluxo aéreo apresentaram mais sono superficial e índice de qualidade do sono inferior aos dos pacientes do grupo controle. As diferenças persistiram mesmo após a remoção dos dois casos com apnéias. Conclui-se que pneumopatas tem sono mais perturbado do que pacientes que consultaram por distúrbio do sono e que esta perturbação é relacionada à hipoxemia noturna.
|
293 |
Avaliação do volume e da função atrial esquerda em pacientes com apneia obstrutiva do sono por meio da ecocardiografia tridimensional / Left Atrial Volume and Function in Patients with Obstructive Sleep Apnea Assessed by Real-Time Three-Dimensional EchocardiographyOliveira, Wercules [UNIFESP] January 2009 (has links) (PDF)
Made available in DSpace on 2015-12-06T22:54:31Z (GMT). No. of bitstreams: 0
Previous issue date: 2009 / Associação Fundo de Incentivo à Psicofarmacologia (AFIP) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Centros de Pesquisa, Inovação e Difusão (CEPID) / A apnéia obstrutiva do sono é considerada um importante problema de saúde pública,
uma vez que é altamente prevalente nos indivíduos em faixa etária produtiva e está
associada à redução da qualidade de vida, hipersonolência diurna, risco de acidentes
automobilísticos e aumento da morbidade e mortalidade cardiovascular. Há crescentes
evidências epidemiológicas e fisiopatológicas de que a apnéia obstrutiva do sono seja um
fator preditor independente de risco para acidente vascular cerebral, fibrilação atrial,
insuficiência cardíaca e morte cardiovascular. A fisiopatogênese do aumento do risco
cardiovascular nos pacientes com apnéia do sono não está completamente esclarecida.
No entanto, infere-se que haja uma importante participação da sobrecarga
catecolaminérgica e das significativas variações da pressão intratorácica como sendo
potenciais fatores de alteração do enchimento ventricular e remodelamento atrial
esquerdo. A associação entre o aumento do átrio esquerdo e risco cardiovascular tem
sido aventada por estudos epidemiológicos, os quais consideram de elevado valor
prognóstico a quantificação das dimensões desta câmara. Este é um estudo duplo-cego,
com distribuição aleatória e placebo-controlado, o qual teve como objetivos a
determinação da ocorrência de alterações morfológicas e funcionais do átrio esquerdo
por meio do ecocardiograma tridimensional, em pacientes com apnéia obstrutiva do sono,
e a avaliação do efeito do tratamento com pressão positiva contínua na reversão dessas
alterações. Cinqüenta e seis pacientes com apnéia do sono e 50 indivíduos controles
com idade e índice de massa corpórea similares foram submetidos à ecocardiografia
tridimensional e bidimensional basal. Do grupo inicial de pacientes, os indivíduos com
índice de apnéia-hipopnéia maior que 20 eventos por hora foram distribuídos a fim de que
recebessem tratamento com dispositivo efetivo de pressão positiva contínua ou
dispositivo placebo por 24 semanas. Ao longo do período de tratamento, esses indivíduos
foram submetidos a 2 exames ecocardiográficos adicionais, na 12ª e na 24ª semanas
após o início do estudo. Na avaliação ecocardiográfica basal, observou-se que havia um
menor desempenho diastólico ventricular esquerdo, maior volume atrial esquerdo e
função atrial esquerda de esvaziamento ativa aumentada nos indivíduos com apnéia do
sono em relação aos controles. A apnéia do sono e a função diastólica foram preditores
independentes do aumento do volume atrial em um modelo de regressão múltipla. Ao
final dos tratamentos foi observado no grupo que fez uso do dispositivo efetivo de
pressão positiva, uma significativa melhora no desempenho diastólico ventricular,
redução do componente ativo de esvaziamento atrial esquerdo e incremento na função
atrial esquerda de esvaziamento passivo. Não foram observadas mudanças nos valores
absolutos do volume máximo do átrio esquerdo após tratamento efetivo. Em conclusão,
este estudo revelou não somente um remodelamento atrial estrutural e funcional
associado à apnéia obstrutiva do sono, mas também o impacto do tratamento dessa
condição na dinâmica diastólica do ventrículo esquerdo e no esvaziamento do átrio
esquerdo. / Obstructive sleep apnea is an important health issue, since it is highly prevalent in the
general adult population and it is associated to reduction in quality of life, excessive day
time sleep, increased risk of automobile accidents and increased cardiovascular risk.
There is a number of epidemiological and physiopathologic evidences that obstructive
sleep apnea is an independent predictor of stroke, atrial fibrillation, heart failure, and
cardiovascular death. The mechanism of the increased cardiovascular risk in patients with
sleep apnea is not totally understood. However, it is assumed that the catecholaminergic
overload and the significant intrathoracic pressure variation during the apneic episodes,
play an important part as potential factors of ventricular filling impairment and left atrium
remodeling. The association between the left atrial enlargement and cardiovascular risk
has been evaluated by epidemiological studies and they consider the quantification of left
atrium dimensions a strong prognostic variable. The main objectives of this doubleblinded,
randomized, and placebo-control study were: (1) to evaluate left atrial volume and
function in patients with obstructive sleep apnea by means of the real-time threedimension
echocardiography; (2) to determine the impact of treatment with continuous
positive airway pressure device on the left atrial dynamics and left ventricular function.
Fifty-six patients with sleep apnea and 50 controls with similar age and body mass index
underwent basal real-time three-dimensional and two-dimension echocardiography. From
the initial patients group, those individuals with apnea-hypopnea index greater than 20
were randomized in order to receive effective treatment or placebo for 24 weeks. They
underwent two additional echocardiographic evaluations, after 12 weeks and 24 week of
treatment. In the basal echocardiographic evaluation, we observed in the patients group:
lower diastolic performance, larger left atrial volume, and reduced left atrial passive
function. Obstructive sleep apnea and left ventricular diastolic function were independent
predictors of an increased left atrial volume in a multiple regression model. In the effective
treatment group we observed a significant improvement in the diastolic performance,
reduction in the left atrial active emptying, and increase in the left atrial passive emptying
from the baseline to the 24 week echocardiographic evaluation. No significant changes
were found on LA fundamental volumes after treatment. As conclusion, we demonstrated
using the real-time three-dimensional echocardiography that obstructive sleep apnea
places a functional burden on the left atrium, resulting in remodeling. This remodeling
could be, at least partially, reversed after effective treatment with CPAP. / BV UNIFESP: Teses e dissertações
|
294 |
Influência do nível de atividade física na modulação condicionada da dor na região orofacial / Influence of physical activity on conditioned pain modulation at orofacial regionLetícia Soares Fiedler 10 May 2018 (has links)
O objetivo desse trabalho foi avaliar a influência do nível de atividade física e da qualidade do sono, de maneira isolada ou combinada, na capacidade de modulação inibitória endógena da dor na região orofacial. Noventa participantes saudáveis com idade entre 18 e 50 anos foram agrupados de acordo com o nível de atividade física em baixo nível (G1), moderado nível (G2) e alto nível (G3), com 15 homens e 15 mulheres em cada grupo. A classificação do nível de atividade física seguiu critérios modificados do Questionário Internacional de Atividade Física (IPAQ, sigla em inglês), preconizando-se a duração e a frequência da atividade física. A qualidade do sono foi avaliada pelo Índice de Qualidade do sono de Pittsburgh (PSQI, sigla em inglês). O paradigma da modulação condicionada da dor (CPM, sigla em inglês) utilizado foi o limiar de dor à pressão (PPT, sigla em inglês) como estímulo teste e imersão da mão em água quente como estímulo condicionante. A análise de variância (ANOVA) foi utilizada para comparação do PPT e do CPM entre os grupos e a interação com a qualidade do sono. O pós-teste de Tukey foi aplicado quando os efeitos principais ou interações se mostraram significantes (p=0,050). De maneira isolada não houve efeito principal significante do nível de atividade física nem da qualidade do sono na capacidade de modulação da dor (p>0,050). Entretanto, foi encontrada uma influência significativa da interação entre qualidade do sono e nível de atividade física na modulação de dor. O grupo com alto nível de atividade física e boa qualidade do sono apresentou maior modulação de dor quando comparado aos que tinham sono ruim, dentro do mesmo grupo (p=0,049), com uma média (DP) do CPM absoluto de, respectivamente, -0,60 (0,34) e -0,17 (0,41). O mesmo aconteceu nos grupos moderado e baixo nível de atividade física e boa qualidade do sono, com uma média (DP) do CPM absoluto de, respectivamente, -0,10 (0,25) e -0,10 (0,52), (Tukey: p<0,028). Pode-se concluir que, isoladamente, a modulação de dor não é significativamente impactada nem pelo nível de atividade física e nem pela qualidade do sono. Entretanto, essa modulação inibitória da dor é influenciada de maneira significativa quando a qualidade do sono e atividade física são consideradas em conjunto, sendo que a modulação inibitória de dor parece ser mais eficiente em indivíduos que apresentam boa qualidade de sono e um alto nível de atividade física. / The aim of this study was to evaluate the separate or combined influence of selfreported physical activity and sleep quality on conditioned pain modulation. Ninety healthy participants aged 18-50 years old were equally divided according to the level of physical activity into low level (G1), moderate level (G2) and high level (G3). The classification of physical activity followed the modified criteria of the International Physical Activity Questionnaire (IPAQ), taking into account the duration and frequency of physical activity. The Pittsburgh Sleep Quality Index (PSQI) assessed sleep quality. The paradigm of conditioned pain modulation (CPM) was the pressure pain threshold (PPT) as test stimulus and hand immersion in hot water as conditioning stimulus. Analysis of variance (ANOVA) was used to compare PPT and CPM between groups and interaction with sleep quality. Tukey\'s post-test was applied when the main effects or interactions were significant (p = 0.050). There was no significant main effect of either physical activity or sleep quality on pain modulation (p> 0.050). However, a significant interaction between sleep quality and level of physical activity on pain modulation was found. The group who reported high level of physical activity and good quality of sleep had a greater pain modulation when compared to: a) those who reported poor sleep, within the same group (p = 0.049), with an absolute CPM mean (SD) of, respectively, - 0.60 (0.34) and -0.17 (0.41); b) the moderate and low level of physical activity and good sleep quality, with an absolute CPM mean (SD) of, respectively, -0.10 (0.25) and -0.10 (0.52) (Tukey: p <0.028). We can conclude that neither the level of physical activity nor the sleep quality significantly affects pain modulation. However, pain inhibitory modulation is influenced significantly when sleep quality and physical activity are combined, and pain inhibitory modulation seems to be more efficient in individuals who have good sleep quality and a high level of physical activity.
|
295 |
Disturbios do sono em funcionarios de um hospital universitarioMontanha, Eleonora Vieira dos Santos January 1996 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciencias da Saude / Made available in DSpace on 2012-10-16T11:33:57Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T21:15:49Z : No. of bitstreams: 1
104377.pdf: 22960352 bytes, checksum: 8988bb713b1f738008f62e9c5ef5c38c (MD5) / Estudo transversal com objetivo de determinar as características do sono e a prevalência de distúrbios do sono entre funcionários de um hospital universitário, utilizando questionário aplicado por entrevista interpessoal em amostra probabilística, aleatória e estratificada segundo as variáveis turno de trabalho, sexo, idade e profissão. Os resultados demonstraram que a prevalência da insônia é de 27%, predominando no sexo feminino, entre plantonistas noturnos e tendendo a aumentar com a idade. Sonolência excessiva ocorre em 14,6% da amostra, associando-se significativamente apenas com o trabalho noturno. Discute sinais sugestivos de privação do sono entre plantonistas noturnos, como a maior tendência a cochilar em serviço. Sugere estratégias para minimizar os distúrbios do sono entre trabalhadores noturnos.
|
296 |
Avaliação do efeito da adenotonsilectomia na saturação de oxigênio medido por oximetria de pulso em crianças com perturbações respiratórias do sonoArrarte, Jaime January 2005 (has links)
Introdução: As perturbações respiratórias do sono (PRS) são uma indicação de adenotonsilectomia em crianças. Entretanto, devido ao fato de a cirurgia ser historicamente eficaz no tratamento das PRS, os pacientes são operados sem uma avaliação adequada da efetividade do tratamento cirúrgico. Há evidências de que a cirurgia não é curativa em todos os pacientes operados. Objetivo: Realizar uma avaliação do efeito da adenotonsilectomia na saturação de oxigênio medido por oximetria de pulso noturna (OPN) em crianças com PRS. Delineamento: Estudo tipo antes e depois. Método: Foram recrutadas crianças com suspeita de PRS atendidas no ambulatório de otorrinolaringologia e com indicação de adenotonsilectomia.Todos realizaram OPN na noite anterior à cirurgia e no mínimo 30 dias após. Resultados: Vinte e sete crianças completaram o estudo. A idade média foi de 5,2 ± 1,8 anos. Dezoito (66,7%) eram do sexo masculino. Os sintomas mais prevalentes foram: roncos (100%), pausas respiratórias (96,3%), respiração bucal noturna (96,3%), sono agitado (81,5%) e sialorréia (74,1%). Vinte e três (85,2%) crianças apresentavam, no exame físico, hiperplasia tonsilar grau 3 e 4. Houve melhora significativa no índice de dessaturação de oxigênio (IDO) pós-operatório(0,65[0,5-1,3]) comparado com o pré-operatório(1,63[1,1-2,4])(p<0,001). Conclusão: A adenotonsilectomia melhorou significativamente a saturação de oxigênio, medida pela OPN, em crianças com PRS.
|
297 |
Avaliação do sono e sua relação com sintomas depressivos e ansiosos em pacientes do sexo feminino com transtornos psiquiátricos hospitalizadasLeite, Cristina Silveira Moraes January 2004 (has links)
Resumo não disponível
|
298 |
Associação entre alterações do sono e qualidade de vida em pacientes com transtorno de humor bipolar em eutimiaGiglio, Larriany Maria Falsin January 2008 (has links)
Introdução: Distúrbios do sono têm sido descrito no transtorno de humor bipolar (THB). Dentre as queixas específicas podemos incluir: os despertares freqüentes durante a noite; pobre qualidade de sono; redução do tempo total de sono e pesadelos. A maioria dos pacientes com THB apresentam problemas relacionados à insônia, mas uma porcentagem significativa de pacientes apresenta sintomas de hipersonia com aumento de horas de sono a noite e sonolência excessiva diurna. Métodos: cento e noventa pacientes bipolares tipo I diagnosticados através de uma entrevista clínica estruturada para transtornos mentais DSM-IV (SCID), foram distribuídos em dois grupos baseados na presença ou ausência de distúrbios do sono verificadas pelas questões 4, 5 e 6 da escala de avaliação para depressão de Hamilton (HAM-D), qualidade de vida (QV), incapacidade e disfunção global foram avaliadas usando o instrumento de avaliação da qualidade de vida da organização mundial da saúde (WHOQOL-Brief), a escala de incapacidade (Sheehan) e a avaliação de funcionalidade global (GAF), respectivamente. Resultados: as queixas de sono tiveram um impacto negativo na qualidade de vida geral, observada na diminuição dos escores da WHOQOL e da GAF e aumento nos escores da Sheehan. Conclusão: os nossos resultados mostraram que pacientes eutímicos possuem alterações significativas do sono e, especialmente, que estas alterações estão fortemente associadas a uma pior qualidade de vida avaliada através da WHOQOL, GAF e SHEEHAN, indicando a importância de manter um sono normal nos pacientes bipolares (PB). Futuros estudos são justificáveis para pesquisar o dano do distúrbio do sono usando escalas mais específicas.
|
299 |
Associação entre o tamanho das tonsilas palatinas e faríngeas com a pressão da artéria pulmonar em criançasGranzotto, Eduardo Homrich January 2009 (has links)
Introdução: Hiperplasia adenotonsilar (HAT) é a principal causa de distúrbios respiratórios do sono em crianças, levando a inúmeras complicações. Cor pulmonale. é a mais severa, onde há aumento insidioso e assintomático da pressão da artéria pulmonar antes da descompensação cardíaca, somente podendo ser diagnosticado por cateterismo cardíaco ou ecodopplercardiografia, exames com indicação e acesso limitado. Adenotonsilectomia é o tratamento de eleição nesses pacientes, entretanto existem atrasos para a cirurgia em vários países, aumentando da morbi-mortalidade por exposição prolongada à patologia. Necessita-se de métodos diagnósticos mais baratos e acessíveis para avaliar quais crianças com HAT estão sob risco de desenvolver complicações cardíacas. Estudos já atestaram que sintomas e exame físico não fazem satisfatoriamente esse papel. Objetivo: O objetivo desse estudo é avaliar correlação entre medida de tonsila palatina e faríngea por radiografia de perfil e pressão da artéria pulmonar aferida por ecodopplercardiografia, em crianças com indicação cirúrgica por HAT. Materiais e Métodos: Estudo transversal com amostra consecutiva de crianças com indicação de adenotonsilectomia por distúrbios respiratórios do sono. O tamanho das tonsilas foi aferido por radiografia de perfil, pressão da artéria pulmonar por ecodopplercardiografia e sintomas clínicos e qualidade de vida pelo questionário OSA-18. A relação tonsila/faringe foi inserida em curva ROC para identificar o melhor ponto de corte para identificar crianças com hipertensão da ateria pulmonar. Resultados: Participaram do estudo 45 crianças com média de idade de 72,0±32,3 anos, sendo que 6 (13%) apresentaram hipertensão da artéria pulmonar pela ecodopplercardiografia. Correlação entre pressão da artéria pulmonar sistólica (sPAP) e relação tonsila/faringe foi forte (r = 0,624; p < 0,0001). Os valores da relação tonsila/faringe foram significativamente maiores nos pacientes com HP do que nos normotensos (p < 0,001). relação adenóide/nasofaringe e OSA-18 não se relacionaram significativamente com as variáveis. O ponto de corte da relação tonsila/faringe identificado na cuva ROC com melhor especificidade ainda com sensibilidade 100% foi 0,66. A média de sPAP nas crianças com relação tonsila/faringe > 0,66 foi significativamente maior que nas com relação tonsila/faringe < 0,66 (p < 0,001). Conclusão: A relação tonsila/faringe apresenta ótima correlação com sPAP em crianças com HAT e indicação cirúrgica por distúrbios respiratórios do sono. Crianças com relação tonsila/faringe > 0,66 podem estar em maior risco de complicações cardíacas, portanto sendo indicado investigação complementar com ECD ou preferência na fila de cirurgia.
|
300 |
Estudo comparativo entre análise cefalométrica radiográfica e exame polissonográfico para diagnóstico da síndrome da apnéia obstrutiva do sonoSilva, Emerson Luiz Costa da January 2001 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T16:56:19Z
No. of bitstreams: 1
Dissertação Emerson Silva.pdf: 465656 bytes, checksum: 731640379127dce40ab114cd303d074c (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-16T18:02:03Z (GMT) No. of bitstreams: 1
Dissertação Emerson Silva.pdf: 465656 bytes, checksum: 731640379127dce40ab114cd303d074c (MD5) / Made available in DSpace on 2013-05-16T18:02:03Z (GMT). No. of bitstreams: 1
Dissertação Emerson Silva.pdf: 465656 bytes, checksum: 731640379127dce40ab114cd303d074c (MD5)
Previous issue date: 2001 / O objetivo deste estudo foi comparar a eficiência do exame cefalométrico radiográfico em relação ao exame polissonográfico para o diagnóstico da Síndrome da Apnéia Obstrutiva do Sono (SAOS), em 60 pacientes com suspeita clínica da condição. Observou-se a confiabilidade dos dados obtidos na cefalometria, vez que esta vem sendo utilizada largamente no protocolo de exame de pacientes apnêicos, principalmente para a determinação dos sítios obstrutivos, servindo desta forma de guia terapêutico. Os resultados demonstraram não haver diferença estatisticamente significante no que diz respeito à capacidade diagnóstica da cefalometria radiográfica e do exame polissonográfico. A cefalometria radiográfica mostrou-se capaz de diagnosticar, satisfatoriamente, indivíduos portadores de SAOS (sensibilidade ? 91,5%). Por outro lado, a cefalometria radiográfica não se mostrou capaz em identificar, de forma satisfatória, indivíduos não portadores de SAOS (especificidade ? 38,5%). Por fim, como a cefalometria radiográfica apresentou alta sensibilidade na determinação dos sítios obstrutivos, concluímos que tal exame deve compor um protocolo, em associação ao exame polissonográfico, de procedimento diagnóstico para indivíduos portadores de SAOS. / Salvador
|
Page generated in 0.0594 seconds