• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 130
  • 28
  • 26
  • 8
  • 5
  • 4
  • 1
  • Tagged with
  • 228
  • 228
  • 87
  • 81
  • 50
  • 41
  • 40
  • 30
  • 29
  • 29
  • 27
  • 22
  • 20
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Hard X-Ray Scanning Microscope Using Nanofocusing Parabolic Refractive Lenses / Rastersondenmikroskopie mit harter Röntgenstrahlung

Patommel, Jens 08 March 2011 (has links) (PDF)
Hard x rays come along with a variety of extraordinary properties which make them an excellent probe for investigation in science, technology and medicine. Their large attenuation length in matter opens up the possibility to use hard x-rays for non-destructive investigation of the inner structure of specimens. Medical radiography is one important example of exploiting this feature. Since their discovery by W. C. Röntgen in 1895, a large variety of x-ray analytical techniques have been developed and successfully applied, such as x-ray crystallography, reflectometry, fluorescence spectroscopy, x-ray absorption spectroscopy, small angle x-ray scattering, and many more. Each of those methods reveals information about certain physical properties, but usually, these properties are an average over the complete sample region illuminated by the x rays. In order to obtain the spatial distribution of those properties in inhomogeneous samples, scanning microscopy techniques have to be applied, screening the sample with a small x-ray beam. The spatial resolution is limited by the finite size of the beam. The availability of highly brilliant x-ray sources at third generation synchrotron radiation facilities together with the development of enhanced focusing x-ray optics made it possible to generate increasingly small high intense x-ray beams, pushing the spatial resolution down to the sub-100 nm range. During this thesis the prototype of a hard x-ray scanning microscope utilizing microstructured nanofocusing lenses was designed, built, and successfully tested. The nanofocusing x-ray lenses were developed by our research group of the Institute of Structural Physics at the Technische Universität Dresden. The prototype instrument was installed at the ESRF beamline ID 13. A wide range of experiments like fluorescence element mapping, fluorescence tomography, x-ray nano-diffraction, coherent x-ray diffraction imaging, and x-ray ptychography were performed as part of this thesis. The hard x-ray scanning microscope provides a stable x-ray beam with a full width at half maximum size of 50-100 nm near the focal plane. The nanoprobe was also used for characterization of nanofocusing lenses, crucial to further improve them. Based on the experiences with the prototype, an advanced version of a hard x-ray scanning microscope is under development and will be installed at the PETRA III beamline P06 dedicated as a user instrument for scanning microscopy. This document is organized as follows. A short introduction motivating the necessity for building a hard x-ray scanning microscope is followed by a brief review of the fundamentals of hard x-ray physics with an emphasis on free-space propagation and interaction with matter. After a discussion of the requirements on the x-ray source for the nanoprobe, the main features of synchrotron radiation from an undulator source are shown. The properties of the nanobeam generated by refractive x-ray lenses are treated as well as a two-stage focusing scheme for tailoring size, flux and the lateral coherence properties of the x-ray focus. The design and realization of the microscope setup is addressed, and a selection of experiments performed with the prototype version is presented, before this thesis is finished with a conclusion and an outlook on prospective plans for an improved microscope setup to be installed at PETRA III. / Aufgrund ihrer hervorragenden Eigenschaften kommt harte Röntgenstrahlung in vielfältiger Weise in der Wissenschaft, Industrie und Medizin zum Einsatz. Vor allem die Fähigkeit, makroskopische Gegenstände zu durchdringen, eröffnet die Möglichkeit, im Innern ausgedehnter Objekte verborgene Strukturen zum Vorschein zu bringen, ohne den Gegenstand zerstören zu müssen. Eine Vielzahl röntgenanalytischer Verfahren wie zum Beispiel Kristallographie, Reflektometrie, Fluoreszenzspektroskopie, Absorptionsspektroskopie oder Kleinwinkelstreuung sind entwickelt und erfolgreich angewendet worden. Jede dieser Methoden liefert gewisse strukturelle, chemische oder physikalische Eigenschaften der Probe zutage, allerdings gemittelt über den von der Röntgenstrahlung beleuchteten Bereich. Um eine ortsaufgelöste Verteilung der durch die Röntgenanalyse gewonnenen Information zu erhalten, bedarf es eines sogenannten Mikrostrahls, durch den die Probe lokal abgetastet werden kann. Die dadurch erreichbare räumliche Auflösung ist durch die Größe des Mikrostrahls begrenzt. Aufgrund der Verfügbarkeit hinreichend brillanter Röntgenquellen in Form von Undulatoren an Synchrotronstrahlungseinrichtungen und des Vorhandenseins verbesserter Röntgenoptiken ist es in den vergangen Jahren gelungen, immer kleinere intensive Röntgenfokusse zu erzeugen und somit das räumliche Auflösungsvermögen der Röntgenrastermikroskope auf unter 100 nm zu verbessern. Gegenstand dieser Arbeit ist der Prototyp eines Rastersondenmikroskops für harte Röntgenstrahlung unter Verwendung refraktiver nanofokussierender Röntgenlinsen, die von unserer Arbeitsgruppe am Institut für Strukturphysik entwickelt und hergestellt werden. Das Rastersondenmikroskop wurde im Rahmen dieser Promotion in Dresden konzipiert und gebaut sowie am Strahlrohr ID 13 des ESRF installiert und erfolgreich getestet. Das Gerät stellt einen hochintensiven Röntgenfokus der Größe 50-100 nm zur Verfügung, mit dem im Verlaufe dieser Doktorarbeit zahlreiche Experimente wie Fluoreszenztomographie, Röntgennanobeugung, Abbildung mittels kohärenter Röntgenbeugung sowie Röntgenptychographie erfolgreich durchgeführt wurden. Das Rastermikroskop dient unter anderem auch dem Charakterisieren der nanofokussierenden Linsen, wobei die dadurch gewonnenen Erkenntnisse in die Herstellung verbesserten Linsen einfließen. Diese Arbeit ist wie folgt strukturiert. Ein kurzes einleitendes Kapitel dient als Motivation für den Bau eines Rastersondenmikroskops für harte Röntgenstrahlung. Es folgt eine Einführung in die Grundlagen der Röntgenphysik mit Hauptaugenmerk auf die Ausbreitung von Röntgenstrahlung im Raum und die Wechselwirkungsmechanismen von Röntgenstrahlung mit Materie. Anschließend werden die Anforderungen an die Röntgenquelle besprochen und die Vorzüge eines Undulators herausgestellt. Wichtige Eigenschaften eines mittels refraktiver Röntgenlinsen erzeugten Röntgenfokus werden behandelt, und das Konzept einer Vorfokussierung zur gezielten Anpassung der transversalen Kohärenzeigenschaften an die Erfordernisse des Experiments wird besprochen. Das Design und die technische Realisierung des Rastermikroskops werden ebenso dargestellt wie eine Auswahl erfolgreicher Experimente, die am Gerät vollzogen wurden. Die Arbeit endet mit einem Ausblick, der mögliche Weiterentwicklungen in Aussicht stellt, unter anderem den Aufbau eines verbesserten Rastermikroskops am PETRA III-Strahlrohr P06.
222

Relaxation des contraintes dans les couches de chromine développées sur alliages modèles (NiCr et Fe47Cr) : apport de la diffraction in situ à haute température sur rayonnement Synchrotron à l’étude du comportement viscoplastique : effets d’éléments réactifs / Stress release in chromia scales formed on model alloys (NiCr and Fe47Cr) : contribution of in situ diffraction at high temperature using Synchrotron radiation in investigating their viscoplastic behaviour : effects of reactive elements

Rakotovao, Felaniaina Nirisoa 30 November 2016 (has links)
L’intégrité des couches protectrices d’oxyde thermiques se développant à haute température à la surface des matériaux métalliques dépend des niveaux de contraintes générées et de leurs mécanismes de relaxation. Le comportement des films de chromine formés sur les alliages modèles NiCr et Fe47Cr a ici été étudié. Les contraintes résiduelles générées après oxydation des substrats à différentes températures (700°C-1000°C) et durées d’oxydation (3h et 18h) ont été déterminées par spectroscopie Raman. Ces contraintes évoluent avec les conditions d’oxydation de manière monotone (système Ni30Cr/Cr2O3) ou non (système Fe47Cr/Cr2O3). Les variations de déformation à l’échelle du grain ont aussi été suivies par AFM. Pour le premier système, relaxation non destructive par fluage de l’oxyde et délamination sont plus ou moins activées en bon accord avec l’évolution des contraintes résiduelles. Dans le second cas, un mode supplémentaire de relaxation des contraintes par fissuration doit également entrer en jeu. Les propriétés viscoplastiques des couches de chromine formées sur Ni30Cr et Ni28Cr ont pu être caractérisées par diffraction in situ à haute température sur rayonnement Synchrotron, en découplant les effets liés à l’activation thermique de ceux liés à la taille de grain. Le type de fluage intervenant dans la relaxation des contraintes générées dans les couches de chromine a pu être mis en évidence en confrontant les résultats obtenus à un modèle théorique de fluage diffusion. La valeur de l’énergie d’activation associée (130 kJ/mol) a montré, par comparaison avec les données de la littérature, que ce mode non destructeur de relaxation est gouverné par le transport des anions d’oxygène aux joints de grains de l’oxyde. L’ajout d’un élément réactif (Y ou Zr) au substrat Ni28Cr provoque, avec l’augmentation de la quantité introduite, un ralentissement croissant de la cinétique de formation des films de chromine. Cependant, cette quantité introduite ne semble exercer aucun effet significatif sur les niveaux de contraintes résiduelles. A l’échelle microscopique, on constate en général une diminution de la taille des grains avec la présence d’éléments réactifs, une double distribution ayant aussi été observée pour les quantités élevées. Les résultats issus des mesures par diffraction in situ et ceux obtenus par AFM (glissement aux joints de grains de l’oxyde) ont montré que la capacité des films de chromine à relaxer les contraintes grâce à leur comportement viscoplastique pourrait être retardée et/ou diminuée en présence des éléments yttrium et zirconium. Toutefois, ce mécanisme pourrait opérer pour des épaisseurs plus faibles des films de chromine. / Integrity of protective oxide scales developing at the metallic alloys surface at high temperature depends on the stress generation and their relaxation mechanisms. In this work, the behaviour of chromia scales formed on NiCr and Fe47Cr model alloys has been investigated. Raman spectroscopy was used to determine the residual stress level in chromia thin films after oxidation at different temperatures (700°C-1000°C) for 3 h and 18 h. A monotonous evolution of residual stresses with oxidation conditions was noted for the Ni30Cr/Cr2O3 system but not for the Fe47Cr/Cr2O3 one. The strain variations at microscopic scale was also determined by using atomic force microscopy. For the first studied system, non destructive relaxation by creep of the oxide and buckling can be more or less activated, in agreement with the residual stresses evolution. And a third additional stress release mode by intra film cracking could take place for the second system. In situ high temperature oxidation coupled with Synchrotron X-rays diffraction was also used to characterize the viscoplastic properties of chromia scales grown on Ni30Cr and Ni28Cr, with dissociating the effects related to thermal activation and grain size. The creep mechanism responsible of stress release in chromia scales has been evidenced by comparing experimental results with a diffusional creep model. Confrontation of the obtained activation energy (130 kJ.mol-1) with literature results has shown that this non destructive relaxation mode was likely governed by grain boundary transport of oxygen species. When a reactive element (Y or Zr) was added to the metallic substrate Ni28Cr, an important decrease of the oxidation rate was noted when increasing the amount of introduced element. No significant effect of this quantity on the residual stress level was however observed. At microscopic scale, a reduction of grain size has been also noted and two distinguished grains distribution appeared for the higher quantities. Results of in situ Synchrotron diffraction measurements and those of atomic force microscopy (grain boundary sliding) showed that the ability of chromia films to release stress thanks to their viscoplastic properties could be delayed and/or decreased with the presence of an active element. However, this mechanism could operate for smaller chromia films thicknesses.
223

[en] MOLECULAR FRAGMENTATION PROCESSES OF WATER IN THE GASEOUS PHASE AFTER MULTIPLE IONIZATION INDUCED BY ENERGETIC BEAM OF LI3+, H+ AND PHOTONS / [pt] PROCESSOS DE FRAGMENTAÇÃO MOLECULAR DA ÁGUA EM ESTADO GASOSO APÓS IONIZAÇÃO MÚLTIPLA INDUZIDA POR FEIXES ENERGÉTICOS DE LI3+, H+ E FÓTONS

12 November 2021 (has links)
[pt] Este estudo trata de processos da fragmentação molecular de água no estado gasoso pelo impacto de feixes energéticos de fótons, H+ e Li3+. As seções de choque absolutas de ionização foram obtidas para os feixes de Li3+, H+ e de fótons. As seções de choque do canal de captura eletrônica, obtidas para o feixe de Li3+, foram investigadas visando determinar as diferenças na fragmentação molecular induzidas pelo processo de transfêrencia de carga ao projétil. O intervalo de energia utilizado nas medidas com o feixe de Li3+ foi de 750 a 5800 keV, enquanto para o feixe de prótons foi selecionada a regiao de energia entre 300 até 2000 keV, mantendo uma faixa de velocidades similar. No caso dos fótons, as fragmentações foram medidas no intervalo de energia de 38 a 170 eV. Para a obtenção dos valores de seção de choque de ionização e de captura, foi aplicado um método para a correção do número de eventos simples (íon + neutro) e pares iônicos. A partir desse método foi possível avaliar a influência desta correção nos valores de seção de choque de ionização. A partir dos valores de frações de fragmentação por impacto de prótons foram desenvolvidas curvas teóricas de seção de choque para produção dos pares iônicos H++OH+ e H++O+. Os resultados obtidos de seção de choque de ionização de pares iônicos foram determinados a partir de resultados teóricos de seções de choque de produção dos fragmentos OH+, O+ e H+ disponíveis na literatura. Os resultados foram comparados e concordam com os valores experimentais para impacto de prótons, obtidos neste trabalho, e com dados para impacto de elétrons disponíveis na literatura. / [en] This study aims to contribute for the understanding of the water molecule multiple ionization by impact of photons, protons and Li3+ ions. The technique selected for such research is Time-of-Flight Spectroscopy of the ions produced as a consequence of the molecular dissociation. Absolute and partial ionization cross sections are obtained for impact with each of these three projectiles. For Li3+ beam, absolute and partial capture cross sections are also obtained. The energy range employed was 38-170 eV for photons beams, 300-2000 keV for H+ beams and 750 up to 5800 keV for Li3+ beams. Corrections for ionization cross section determination are usually necessary. Methods for this were developed and applied to the current data. Values for these corrections are presented and discussed. The obtained results are compared with literature data, exhibiting unexpected features. As an example, the production rates of OH+ and H+ fragments by two beams (photons and electrons) having a very different nature are very similar behavior. The data from the water molecule fragmentation by H+ beam enabled the determination of fragmentation factors. The knowledge of these factors made possible to calculate, using a method developed in this work and also theoretical data from literature based on production data of OH+, O+ and H+, new theoretical curves concerning pair production (H+ + OH+ and H+O+).
224

Entwicklung einer hochauflösenden Kamera für die Mikroskopie mit harter Röntgenstrahlung

Patommel, Jens 17 November 2003 (has links)
Seit mit den Synchrotronstrahlungsquellen dritter Generation hochbrillante Röntgenquellen zur Verfügung stehen, haben sich Vollfeldmikroskopie und Rastersondenmikroskopie mit harter Röntgenstrahlung als besonders nützliche Untersuchungsmethoden etabliert. Insbesondere bei der vergrößernden Mikroskopie mit harter Röntgenstrahlung werden Röntgenkameras mit hoher Anforderung bezüglich der Ortsauflösung benötigt. Im Rahmen dieser Diplomarbeit wurde ein zweidimensionaler Röntgendetektor für die Mikroskopie mit harter Röntgenstrahlung entworfen, gebaut und im Experiment getestet und charakterisiert. Hauptaugenmerk war dabei ein möglichst hohes Ortsauflösungsvermögen des Detektors verbunden mit einem großen effektiven dynamischen Bereich. Als vielversprechendes Konzept erwies sich dabei die Verwendung eines einkristallinen Szintillators, der mittels einer Mikroskopoptik auf einen CCD-Chip abgebildet wird. Im Experiment stellte sich heraus, dass der im Zuge dieser Diplomarbeit konzipierte Flächendetektor sämtliche an ihn gestellten Anforderungen hervorragend erfüllt. Obwohl ursprünglich für die vergrößernde Tomographie mit harter Röntgenstrahlung entwickelt, findet die Röntgenkamera darüber hinaus beim Justieren nanofokussierender refraktiver Röntgenlinsen in Rastersondenmikroskopen Verwendung.:1 Einleitung . . . . . . . . . . . . . . . . . . . . . . . . 1 2 Das Erzeugen von Röntgenstrahlung . . . . . . . . . . . . 3 2.1 Röntgenröhren . . . . . . . . . . . . . . . . . . . . . 3 2.2 Synchrotronstrahlung . . . . . . . . . . . . . . . . . . 6 2.3 Sonstige Röntgenquellen . . . . . . . . . . . . . . . . 10 3 Röntgendetektoren . . . . . . . . . . . . . . . . . . . . 11 3.1 Gasionisationsdetektoren . . . . . . . . . . . . . . . . 11 3.2 Halbleiterdetektoren . . . . . . . . . . . . . . . . . . 13 3.3 Szintillationsdetektoren . . . . . . . . . . . . . . . . 16 3.4 Röntgenfilme . . . . . . . . . . . . . . . . . . . . . . 17 3.5 Bildplatten . . . . . . . . . . . . . . . . . . . . . . 18 3.6 CCD-Detektoren . . . . . . . . . . . . . . . . . . . . . 20 3.6.1 Funktionsweise eines CCD-Chips . . . . . . . . . . . . 20 3.6.2 Direkte CCD-Detektoren . . . . . . . . . . . . . . . . 24 3.6.3 CCD-Detektoren mit Faseroptiken . . . . . . . . . . . 25 3.6.4 CCD-Detektoren mit Linsenoptiken . . . . . . . . . . . 26 4 Abbilden mit Röntgenstrahlung . . . . . . . . . . . . . . 29 4.1 Transmission von Röntgenstrahlung durch eine Probe . . . 30 4.2 Detektormittelwert . . . . . . . . . . . . . . . . . . . 34 4.3 Absorptionskontrast . . . . . .. . . . . . . . . . . . . 35 4.4 Beugung und Propagation . . . . . . . . . . . . . . . . 36 4.5 Korrelation und wechselseitige Intensität . . . . . . . 38 4.6 Das Theorem von Van Cittert und Zernike . . . . . . . . 41 4.7 Projektionsabbildung . . . . . . . . . . . . . . . . . . 42 4.8 Das Röntgenmikroskop . . . . . . . . . . . . . . . . . . 43 5 Hochauflösende Röntgenkamera . . . . . . . . . . . . . . . 45 5.1 Anforderungen an den Detektor . . . . . . . . . . . . . 45 5.2 Szintillator . . . . . . . . . . . . . . . . . . . . . . 46 5.3 Mikroskop . . . . . . . . . . . . . . . . . . . . . . . 53 5.4 CCD-Kamera . . . . . . . . . . . . . . . . . . . . . . . 55 6 Charakterisierung des Detektors . . . . . . . . . . . . . 61 6.1 Versuchsaufbau . . . . . . . . . . . . . . . . . . . . . 61 6.2 Auswertung . . . . . . . . . . . . . . . . . . . . . . . 63 6.3 Nickel-Gitter . . . . . . . . . . . . . . . . . . . . . 64 6.4 Goldstreifen . . . . . . . . . . . . . . . . . . . . . . 71 6.5 Mikroprozessor . . . . . . . . . . . . . . . . . . . . . 75 6.6 Einfluss der Quellgröße . . . . . . . . . . . . . . . . . 79 7 Zusammenfassung und Ausblick . . . . . . . . . . . . . . . 81 Literaturverzeichnis . . . . . . . . . . . . . . . . . . . . 85 Abbildungsverzeichnis . . . . . . . . . . . . . . . . . . . 89 Tabellenverzeichnis . . . . . . . . . . . . . . . . . . . . 91 Danksagung . . . . . . . . . . . . . . . . . . . . . . . . . 93 / With the advent of highly-brilliant third generation synchrotron radiation sources, hard x-ray full-field microscopy and hard x-ray scanning microscopy were developed and have been shown to be excellent methods for scientific investigations. Especially for magnified hard x-ray full-field microscopy, there is the need for two-dimensional x-ray detectors with highest demands on spatial resolution and effective dynamic range. In the course of this diploma thesis, such an area x-ray detector with high spatial resolution and large dynamic range was designed and built and then tested and characterized in experiment. The high-resolution x-ray camera consists of a visible light microscope which images the sensitive layer of a single-crystal scintillator on the CCD chip of a CCD camera. A test experiment gave evidence that the x-ray camera actually fulfills all the requirements with regard to spatial resolution, sensitivity and effective dynamic range. Originally, the detector was developed for magnified hard x-ray tomography, but in addition, it is applied for alignment purposes of nanofocusing refractive x-ray lenses in a hard x-ray scanning microscope.:1 Einleitung . . . . . . . . . . . . . . . . . . . . . . . . 1 2 Das Erzeugen von Röntgenstrahlung . . . . . . . . . . . . 3 2.1 Röntgenröhren . . . . . . . . . . . . . . . . . . . . . 3 2.2 Synchrotronstrahlung . . . . . . . . . . . . . . . . . . 6 2.3 Sonstige Röntgenquellen . . . . . . . . . . . . . . . . 10 3 Röntgendetektoren . . . . . . . . . . . . . . . . . . . . 11 3.1 Gasionisationsdetektoren . . . . . . . . . . . . . . . . 11 3.2 Halbleiterdetektoren . . . . . . . . . . . . . . . . . . 13 3.3 Szintillationsdetektoren . . . . . . . . . . . . . . . . 16 3.4 Röntgenfilme . . . . . . . . . . . . . . . . . . . . . . 17 3.5 Bildplatten . . . . . . . . . . . . . . . . . . . . . . 18 3.6 CCD-Detektoren . . . . . . . . . . . . . . . . . . . . . 20 3.6.1 Funktionsweise eines CCD-Chips . . . . . . . . . . . . 20 3.6.2 Direkte CCD-Detektoren . . . . . . . . . . . . . . . . 24 3.6.3 CCD-Detektoren mit Faseroptiken . . . . . . . . . . . 25 3.6.4 CCD-Detektoren mit Linsenoptiken . . . . . . . . . . . 26 4 Abbilden mit Röntgenstrahlung . . . . . . . . . . . . . . 29 4.1 Transmission von Röntgenstrahlung durch eine Probe . . . 30 4.2 Detektormittelwert . . . . . . . . . . . . . . . . . . . 34 4.3 Absorptionskontrast . . . . . .. . . . . . . . . . . . . 35 4.4 Beugung und Propagation . . . . . . . . . . . . . . . . 36 4.5 Korrelation und wechselseitige Intensität . . . . . . . 38 4.6 Das Theorem von Van Cittert und Zernike . . . . . . . . 41 4.7 Projektionsabbildung . . . . . . . . . . . . . . . . . . 42 4.8 Das Röntgenmikroskop . . . . . . . . . . . . . . . . . . 43 5 Hochauflösende Röntgenkamera . . . . . . . . . . . . . . . 45 5.1 Anforderungen an den Detektor . . . . . . . . . . . . . 45 5.2 Szintillator . . . . . . . . . . . . . . . . . . . . . . 46 5.3 Mikroskop . . . . . . . . . . . . . . . . . . . . . . . 53 5.4 CCD-Kamera . . . . . . . . . . . . . . . . . . . . . . . 55 6 Charakterisierung des Detektors . . . . . . . . . . . . . 61 6.1 Versuchsaufbau . . . . . . . . . . . . . . . . . . . . . 61 6.2 Auswertung . . . . . . . . . . . . . . . . . . . . . . . 63 6.3 Nickel-Gitter . . . . . . . . . . . . . . . . . . . . . 64 6.4 Goldstreifen . . . . . . . . . . . . . . . . . . . . . . 71 6.5 Mikroprozessor . . . . . . . . . . . . . . . . . . . . . 75 6.6 Einfluss der Quellgröße . . . . . . . . . . . . . . . . . 79 7 Zusammenfassung und Ausblick . . . . . . . . . . . . . . . 81 Literaturverzeichnis . . . . . . . . . . . . . . . . . . . . 85 Abbildungsverzeichnis . . . . . . . . . . . . . . . . . . . 89 Tabellenverzeichnis . . . . . . . . . . . . . . . . . . . . 91 Danksagung . . . . . . . . . . . . . . . . . . . . . . . . . 93
225

Structural and magnetic properties of ultrathin Fe3O4 films: cation- and lattice-site-selective studies by synchrotron radiation-based techniques

Pohlmann, Tobias 19 August 2021 (has links)
This work investigates the growth dynamic of the reactive molecular beam epitaxy of Fe3O4 films, and its impact on the cation distribution as well as on the magnetic and structural properties at the surface and the interfaces. In order to study the structure and composition of Fe3O4 films during growth, time-resolved high-energy x-ray diffraction (tr-HEXRD) and time-resolved hard x-ray photoelectron spectroscopy (tr-HAXPES) measurements are used to monitor the deposition process of Fe3O4 ultrathin films on SrTiO3(001), MgO(001) and NiO/MgO(001). For Fe3O4\SrTiO3(001) is found that the film first grows in a disordered island structure, between thicknesses of 1.5nm to 3nm in FeO islands and finally in the inverse spinel structure of Fe3O4, displaying (111) nanofacets on the surface. The films on MgO(001) and NiO/MgO(001) show a similar result, with the exception that the films are not disordered in the early growth stage, but form islands which immediately exhibit a crystalline FeO phase up to a thickness of 1nm. After that, the films grown in the inverse spinel structure on both MgO(001) and NiO/MgO(001). Additionally, the tr-HAXPES measurements of Fe3O4/SrTiO3(001) demonstrate that the FeO phase is only stable during the deposition process, but turns into a Fe3O4 phase when the deposition is interrupted. This suggests that this FeO layer is a strictly dynamic property of the growth process, and might not be retained in the as-grown films. In order to characterize the as-grown films, a technique is introduced to extract the cation depth distribution of Fe3O4 films from magnetooptical depth profiles obtained by fitting x-ray resonant magnetic reflectivity (XRMR) curves. To this end, x-ray absorption (XAS) and x-ray magnetic circular dichroism (XMCD) spectra are recorded as well as XRMR curves to obtain magnetooptical depth profiles. To attribute these magnetooptical depth profiles to the depth distribution of the cations, multiplet calculations are fitted to the XMCD data. From these calculations, the cation contributions at the three resonant energies of the XMCD spectrum can be evaluated. Recording XRMR curves at those energies allows to resolve the magnetooptical depth profiles of the three iron cation species in Fe3O4. This technique is used to resolve the cation stoichiometry at the surface of Fe3O4/MgO(001) films and at the interfaces of Fe3O4/MgO(001) and Fe3O4/NiO. The first unit cell of the Fe3O4(001) surface shows an excess of Fe3+ cations, likely related to a subsurface cation-vacancy reconstruction of the Fe3O4(001) surface, but the magnetic order of the different cation species appears to be not disturbed in this reconstructed layer. Beyond this layer, the magnetic order of all three iron cation species in Fe3O4/MgO(001) is stable for the entire film with no interlayer or magnetic dead layer at the interface. For Fe3O4/NiO films, we unexpectedly observe a magnetooptical absorption at the Ni L3 edge in the NiO film corresponding to a ferromagnetic order throughout the entire NiO film, which is antiferromagnetic in the bulk. Additionally, the magnetooptical profiles indicate a single intermixed layer containing both Fe2+ and Ni2+ cations.
226

Hard X-Ray Scanning Microscope Using Nanofocusing Parabolic Refractive Lenses

Patommel, Jens 12 November 2010 (has links)
Hard x rays come along with a variety of extraordinary properties which make them an excellent probe for investigation in science, technology and medicine. Their large attenuation length in matter opens up the possibility to use hard x-rays for non-destructive investigation of the inner structure of specimens. Medical radiography is one important example of exploiting this feature. Since their discovery by W. C. Röntgen in 1895, a large variety of x-ray analytical techniques have been developed and successfully applied, such as x-ray crystallography, reflectometry, fluorescence spectroscopy, x-ray absorption spectroscopy, small angle x-ray scattering, and many more. Each of those methods reveals information about certain physical properties, but usually, these properties are an average over the complete sample region illuminated by the x rays. In order to obtain the spatial distribution of those properties in inhomogeneous samples, scanning microscopy techniques have to be applied, screening the sample with a small x-ray beam. The spatial resolution is limited by the finite size of the beam. The availability of highly brilliant x-ray sources at third generation synchrotron radiation facilities together with the development of enhanced focusing x-ray optics made it possible to generate increasingly small high intense x-ray beams, pushing the spatial resolution down to the sub-100 nm range. During this thesis the prototype of a hard x-ray scanning microscope utilizing microstructured nanofocusing lenses was designed, built, and successfully tested. The nanofocusing x-ray lenses were developed by our research group of the Institute of Structural Physics at the Technische Universität Dresden. The prototype instrument was installed at the ESRF beamline ID 13. A wide range of experiments like fluorescence element mapping, fluorescence tomography, x-ray nano-diffraction, coherent x-ray diffraction imaging, and x-ray ptychography were performed as part of this thesis. The hard x-ray scanning microscope provides a stable x-ray beam with a full width at half maximum size of 50-100 nm near the focal plane. The nanoprobe was also used for characterization of nanofocusing lenses, crucial to further improve them. Based on the experiences with the prototype, an advanced version of a hard x-ray scanning microscope is under development and will be installed at the PETRA III beamline P06 dedicated as a user instrument for scanning microscopy. This document is organized as follows. A short introduction motivating the necessity for building a hard x-ray scanning microscope is followed by a brief review of the fundamentals of hard x-ray physics with an emphasis on free-space propagation and interaction with matter. After a discussion of the requirements on the x-ray source for the nanoprobe, the main features of synchrotron radiation from an undulator source are shown. The properties of the nanobeam generated by refractive x-ray lenses are treated as well as a two-stage focusing scheme for tailoring size, flux and the lateral coherence properties of the x-ray focus. The design and realization of the microscope setup is addressed, and a selection of experiments performed with the prototype version is presented, before this thesis is finished with a conclusion and an outlook on prospective plans for an improved microscope setup to be installed at PETRA III.:1 Introduction ............................................... 1 2 Basic Properties of Hard X Rays ............................ 3 2.1 Free Propagation of X Rays ............................... 3 2.1.1 The Helmholtz Equation ................................. 4 2.1.2 Integral Theorem of Helmholtz and Kirchhoff ............ 6 2.1.3 Fresnel-Kirchhoff's Diffraction Formula ................ 8 2.1.4 Fresnel-Kirchhoff Propagation .......................... 11 2.2 Interaction of X Rays with Matter ........................ 13 2.2.1 Complex Index of Refraction ............................ 13 2.2.2 Attenuation ............................................ 15 2.2.3 Refraction ............................................. 18 3 The X-Ray Source ........................................... 21 3.1 Requirements ............................................. 21 3.1.1 Energy and Energy Bandwidth ............................ 21 3.1.2 Source Size and Divergence ............................. 23 3.1.3 Brilliance ............................................. 23 3.2 Synchrotron Radiation .................................... 24 3.3 Layout of a Synchrotron Radiation Facility ............... 27 3.4 Liénard-Wiechert Fields .................................. 29 3.5 Dipole Magnets ........................................... 31 3.6 Insertion Devices ........................................ 36 3.6.1 Multipole Wigglers ..................................... 36 3.6.2 Undulators ............................................. 37 4 X-Ray Optics ............................................... 39 4.1 Refractive X-Ray Lenses .................................. 40 4.2 Compound Parabolic Refractive Lenses (CRLs) .............. 41 4.3 Nanofocusing Lenses (NFLs) ............................... 43 4.4 Adiabatically Focusing Lenses (AFLs) ..................... 45 4.5 Focal Distance ........................................... 46 4.6 Transverse Focus Size .................................... 50 4.7 Beam Caustic ............................................. 52 4.8 Depth of Focus ........................................... 53 4.9 Beam Divergence .......................................... 53 4.10 Chromaticity ............................................ 54 4.11 Transmission and Cross Section .......................... 55 4.12 Transverse Coherence .................................... 56 4.12.1 Mutual Intensity Function ............................. 57 4.12.2 Free Propagation of Mutual Intensity .................. 57 4.12.3 Mutual Intensity In The Focal Plane ................... 58 4.12.4 Diffraction Limited Focus ............................. 59 4.13 Coherent Flux ........................................... 60 4.14 Two-Stage Focusing ...................................... 64 4.14.1 The Prefocusing Parameter ............................. 65 4.14.2 Required Refractive Power ............................. 67 4.14.3 Flux Considerations ................................... 70 4.14.4 Astigmatic Prefocusing ................................ 75 5 Nanoprobe Setup ............................................ 77 5.1 X-Ray Optics ............................................. 78 5.1.1 Nanofocusing Lenses .................................... 79 5.1.2 Entry Slits ............................................ 82 5.1.3 Pinhole ................................................ 82 5.1.4 Additional Shielding ................................... 83 5.1.5 Vacuum and Helium Tubes ................................ 83 5.2 Sample Stages ............................................ 84 5.2.1 High Resolution Scanner ................................ 84 5.2.2 High Precision Rotational Stage ........................ 85 5.2.3 Coarse Linear Stages ................................... 85 5.2.4 Goniometer Head ........................................ 85 5.3 Detectors ................................................ 86 5.3.1 High Resolution X-Ray Camera ........................... 86 5.3.2 Diffraction Cameras .................................... 89 5.3.3 Energy Dispersive Detectors ............................ 91 5.3.4 Photodiodes ............................................ 93 5.4 Control Software ......................................... 94 6 Experiments ................................................ 97 6.1 Lens Alignment ........................................... 97 6.2 Focus Characterization ................................... 99 6.2.1 Knife-Edge Scans ....................................... 100 6.2.2 Far-Field Measurements ................................. 102 6.2.3 X-Ray Ptychography ..................................... 103 6.3 Fluorescence Spectroscopy ................................ 105 6.3.1 Fluorescence Element Mapping ........................... 107 6.3.2 Fluorescence Tomography ................................ 110 6.4 Diffraction Experiments .................................. 111 6.4.1 Microdiffraction on Phase Change Media ................. 112 6.4.2 Microdiffraction on Stranski-Krastanow Islands ......... 113 6.4.3 Coherent X-Ray Diffraction Imaging of Gold Particles ... 115 6.4.4 X-Ray Ptychography of a Nano-Structured Microchip ...... 117 7 Conclusion and Outlook ..................................... 121 Bibliography ................................................. 125 List of Figures .............................................. 139 List of Publications ......................................... 141 Danksagung ................................................... 145 Curriculum Vitae ............................................. 149 Erklärung .................................................... 151 / Aufgrund ihrer hervorragenden Eigenschaften kommt harte Röntgenstrahlung in vielfältiger Weise in der Wissenschaft, Industrie und Medizin zum Einsatz. Vor allem die Fähigkeit, makroskopische Gegenstände zu durchdringen, eröffnet die Möglichkeit, im Innern ausgedehnter Objekte verborgene Strukturen zum Vorschein zu bringen, ohne den Gegenstand zerstören zu müssen. Eine Vielzahl röntgenanalytischer Verfahren wie zum Beispiel Kristallographie, Reflektometrie, Fluoreszenzspektroskopie, Absorptionsspektroskopie oder Kleinwinkelstreuung sind entwickelt und erfolgreich angewendet worden. Jede dieser Methoden liefert gewisse strukturelle, chemische oder physikalische Eigenschaften der Probe zutage, allerdings gemittelt über den von der Röntgenstrahlung beleuchteten Bereich. Um eine ortsaufgelöste Verteilung der durch die Röntgenanalyse gewonnenen Information zu erhalten, bedarf es eines sogenannten Mikrostrahls, durch den die Probe lokal abgetastet werden kann. Die dadurch erreichbare räumliche Auflösung ist durch die Größe des Mikrostrahls begrenzt. Aufgrund der Verfügbarkeit hinreichend brillanter Röntgenquellen in Form von Undulatoren an Synchrotronstrahlungseinrichtungen und des Vorhandenseins verbesserter Röntgenoptiken ist es in den vergangen Jahren gelungen, immer kleinere intensive Röntgenfokusse zu erzeugen und somit das räumliche Auflösungsvermögen der Röntgenrastermikroskope auf unter 100 nm zu verbessern. Gegenstand dieser Arbeit ist der Prototyp eines Rastersondenmikroskops für harte Röntgenstrahlung unter Verwendung refraktiver nanofokussierender Röntgenlinsen, die von unserer Arbeitsgruppe am Institut für Strukturphysik entwickelt und hergestellt werden. Das Rastersondenmikroskop wurde im Rahmen dieser Promotion in Dresden konzipiert und gebaut sowie am Strahlrohr ID 13 des ESRF installiert und erfolgreich getestet. Das Gerät stellt einen hochintensiven Röntgenfokus der Größe 50-100 nm zur Verfügung, mit dem im Verlaufe dieser Doktorarbeit zahlreiche Experimente wie Fluoreszenztomographie, Röntgennanobeugung, Abbildung mittels kohärenter Röntgenbeugung sowie Röntgenptychographie erfolgreich durchgeführt wurden. Das Rastermikroskop dient unter anderem auch dem Charakterisieren der nanofokussierenden Linsen, wobei die dadurch gewonnenen Erkenntnisse in die Herstellung verbesserten Linsen einfließen. Diese Arbeit ist wie folgt strukturiert. Ein kurzes einleitendes Kapitel dient als Motivation für den Bau eines Rastersondenmikroskops für harte Röntgenstrahlung. Es folgt eine Einführung in die Grundlagen der Röntgenphysik mit Hauptaugenmerk auf die Ausbreitung von Röntgenstrahlung im Raum und die Wechselwirkungsmechanismen von Röntgenstrahlung mit Materie. Anschließend werden die Anforderungen an die Röntgenquelle besprochen und die Vorzüge eines Undulators herausgestellt. Wichtige Eigenschaften eines mittels refraktiver Röntgenlinsen erzeugten Röntgenfokus werden behandelt, und das Konzept einer Vorfokussierung zur gezielten Anpassung der transversalen Kohärenzeigenschaften an die Erfordernisse des Experiments wird besprochen. Das Design und die technische Realisierung des Rastermikroskops werden ebenso dargestellt wie eine Auswahl erfolgreicher Experimente, die am Gerät vollzogen wurden. Die Arbeit endet mit einem Ausblick, der mögliche Weiterentwicklungen in Aussicht stellt, unter anderem den Aufbau eines verbesserten Rastermikroskops am PETRA III-Strahlrohr P06.:1 Introduction ............................................... 1 2 Basic Properties of Hard X Rays ............................ 3 2.1 Free Propagation of X Rays ............................... 3 2.1.1 The Helmholtz Equation ................................. 4 2.1.2 Integral Theorem of Helmholtz and Kirchhoff ............ 6 2.1.3 Fresnel-Kirchhoff's Diffraction Formula ................ 8 2.1.4 Fresnel-Kirchhoff Propagation .......................... 11 2.2 Interaction of X Rays with Matter ........................ 13 2.2.1 Complex Index of Refraction ............................ 13 2.2.2 Attenuation ............................................ 15 2.2.3 Refraction ............................................. 18 3 The X-Ray Source ........................................... 21 3.1 Requirements ............................................. 21 3.1.1 Energy and Energy Bandwidth ............................ 21 3.1.2 Source Size and Divergence ............................. 23 3.1.3 Brilliance ............................................. 23 3.2 Synchrotron Radiation .................................... 24 3.3 Layout of a Synchrotron Radiation Facility ............... 27 3.4 Liénard-Wiechert Fields .................................. 29 3.5 Dipole Magnets ........................................... 31 3.6 Insertion Devices ........................................ 36 3.6.1 Multipole Wigglers ..................................... 36 3.6.2 Undulators ............................................. 37 4 X-Ray Optics ............................................... 39 4.1 Refractive X-Ray Lenses .................................. 40 4.2 Compound Parabolic Refractive Lenses (CRLs) .............. 41 4.3 Nanofocusing Lenses (NFLs) ............................... 43 4.4 Adiabatically Focusing Lenses (AFLs) ..................... 45 4.5 Focal Distance ........................................... 46 4.6 Transverse Focus Size .................................... 50 4.7 Beam Caustic ............................................. 52 4.8 Depth of Focus ........................................... 53 4.9 Beam Divergence .......................................... 53 4.10 Chromaticity ............................................ 54 4.11 Transmission and Cross Section .......................... 55 4.12 Transverse Coherence .................................... 56 4.12.1 Mutual Intensity Function ............................. 57 4.12.2 Free Propagation of Mutual Intensity .................. 57 4.12.3 Mutual Intensity In The Focal Plane ................... 58 4.12.4 Diffraction Limited Focus ............................. 59 4.13 Coherent Flux ........................................... 60 4.14 Two-Stage Focusing ...................................... 64 4.14.1 The Prefocusing Parameter ............................. 65 4.14.2 Required Refractive Power ............................. 67 4.14.3 Flux Considerations ................................... 70 4.14.4 Astigmatic Prefocusing ................................ 75 5 Nanoprobe Setup ............................................ 77 5.1 X-Ray Optics ............................................. 78 5.1.1 Nanofocusing Lenses .................................... 79 5.1.2 Entry Slits ............................................ 82 5.1.3 Pinhole ................................................ 82 5.1.4 Additional Shielding ................................... 83 5.1.5 Vacuum and Helium Tubes ................................ 83 5.2 Sample Stages ............................................ 84 5.2.1 High Resolution Scanner ................................ 84 5.2.2 High Precision Rotational Stage ........................ 85 5.2.3 Coarse Linear Stages ................................... 85 5.2.4 Goniometer Head ........................................ 85 5.3 Detectors ................................................ 86 5.3.1 High Resolution X-Ray Camera ........................... 86 5.3.2 Diffraction Cameras .................................... 89 5.3.3 Energy Dispersive Detectors ............................ 91 5.3.4 Photodiodes ............................................ 93 5.4 Control Software ......................................... 94 6 Experiments ................................................ 97 6.1 Lens Alignment ........................................... 97 6.2 Focus Characterization ................................... 99 6.2.1 Knife-Edge Scans ....................................... 100 6.2.2 Far-Field Measurements ................................. 102 6.2.3 X-Ray Ptychography ..................................... 103 6.3 Fluorescence Spectroscopy ................................ 105 6.3.1 Fluorescence Element Mapping ........................... 107 6.3.2 Fluorescence Tomography ................................ 110 6.4 Diffraction Experiments .................................. 111 6.4.1 Microdiffraction on Phase Change Media ................. 112 6.4.2 Microdiffraction on Stranski-Krastanow Islands ......... 113 6.4.3 Coherent X-Ray Diffraction Imaging of Gold Particles ... 115 6.4.4 X-Ray Ptychography of a Nano-Structured Microchip ...... 117 7 Conclusion and Outlook ..................................... 121 Bibliography ................................................. 125 List of Figures .............................................. 139 List of Publications ......................................... 141 Danksagung ................................................... 145 Curriculum Vitae ............................................. 149 Erklärung .................................................... 151
227

Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe

Rahn, Helene 13 February 2012 (has links) (PDF)
Im Rahmen der vorliegenden Dissertationsschrift „Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe“ wurden tomographische Untersuchungen an biologischen Objekten durchgeführt. Bei diesen Objekten handelt es sich um Gewebeproben nach minimal-invasiven Krebstherapien wie zum Beispiel magnetischem Drug Targeting und magnetischer Wärmebehandlung. Der Erfolg dieser Therapien ist sowohl abhängig von der korrekten Verteilung der magnetischen Nanopartikel als auch von der Tatsache, dass diese in der Zielregion in einer ausreichenden Menge vorhanden sind. Das Vorliegen dieser beiden Voraussetzungen ist in der vorliegenden Arbeit untersucht worden. Dabei lag der Schwerpunkt der Arbeit auf der Quantifizierung von magnetischem Material in unterschiedlichen biologischen Gewebeproben mittels Röntgenmikrocomputertomographie (XµCT). Für diesen Zweck wurde ein Kalibrationssystem mit speziellen Phantomen entwickelt, mit dessen Hilfe eine Nanopartikelkonzentration einem Grauwert voxelweise zugewiesen werden kann. Mit Hilfe der Kalibration kann der Nanopartikelgehalt sowohl in monochromatischen als auch in polychromatischen tomographischen Daten im Vergleich zu magnetorelaxometrischen Ergebnissen mit wenigen Prozent Abweichung ermittelt werden. Trotz Polychromasie und damit einhergehenden Artefakten können 3-dimensionale röntgentomographische Datensätze mit einer geringfügigen Konzentrationsabweichung im Vergleich zur quantitativen Messmethode Magnetorelaxometrie semi-quantitativ ausgewertet werden. / The success of the minimal invasive cancer therapies, called magnetic drug targeting and magnetic heating treatment, depends strongly on the correct distribution of the magnetic nanoparticles on one side. On the other side it depends on the fact that a sufficient amount of magnetic nanoparticles carrying drugs is accumulated in the target region. To study whether these two requirements are fulfilled motivates this PhD thesis „Semi-quantitative X-ray-tomography examinations of biodistribution of magnetic nanoparticles in biological tissues“. The analysis of the distribution of the magnetic nanoparticles in tumours and other tissue examples is realized by means of X-ray-micro computer tomography (XμCT). The work focuses on the quantification of the magnetic nanoparticles in different biological tissue samples by means of XµCT. A calibration of the tomographic devices with adequate phantoms, developed in the frame of this work, opens now the possibility to analyze tomographic data in a semi-quantitative manner. Thus, the nanoparticle concentration can be allocated voxel-wise to the grey values of the three-dimensional tomographic data. With the help of calibration of the tomography equipments used, polychromatic as well as monochromatic three-dimensional representations of objects can be analyzed with regard to the biodistribution of magnetic nanoparticles as well as with regard to their quantity. The semi-quantitative results have been compared with results obtained with a quantitative measurement method magnetorelaxometry (MRX). Thereby a good agreement of the semi-quantitative and quantitative data has been figured out.
228

Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe

Rahn, Helene 12 December 2011 (has links)
Im Rahmen der vorliegenden Dissertationsschrift „Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe“ wurden tomographische Untersuchungen an biologischen Objekten durchgeführt. Bei diesen Objekten handelt es sich um Gewebeproben nach minimal-invasiven Krebstherapien wie zum Beispiel magnetischem Drug Targeting und magnetischer Wärmebehandlung. Der Erfolg dieser Therapien ist sowohl abhängig von der korrekten Verteilung der magnetischen Nanopartikel als auch von der Tatsache, dass diese in der Zielregion in einer ausreichenden Menge vorhanden sind. Das Vorliegen dieser beiden Voraussetzungen ist in der vorliegenden Arbeit untersucht worden. Dabei lag der Schwerpunkt der Arbeit auf der Quantifizierung von magnetischem Material in unterschiedlichen biologischen Gewebeproben mittels Röntgenmikrocomputertomographie (XµCT). Für diesen Zweck wurde ein Kalibrationssystem mit speziellen Phantomen entwickelt, mit dessen Hilfe eine Nanopartikelkonzentration einem Grauwert voxelweise zugewiesen werden kann. Mit Hilfe der Kalibration kann der Nanopartikelgehalt sowohl in monochromatischen als auch in polychromatischen tomographischen Daten im Vergleich zu magnetorelaxometrischen Ergebnissen mit wenigen Prozent Abweichung ermittelt werden. Trotz Polychromasie und damit einhergehenden Artefakten können 3-dimensionale röntgentomographische Datensätze mit einer geringfügigen Konzentrationsabweichung im Vergleich zur quantitativen Messmethode Magnetorelaxometrie semi-quantitativ ausgewertet werden. / The success of the minimal invasive cancer therapies, called magnetic drug targeting and magnetic heating treatment, depends strongly on the correct distribution of the magnetic nanoparticles on one side. On the other side it depends on the fact that a sufficient amount of magnetic nanoparticles carrying drugs is accumulated in the target region. To study whether these two requirements are fulfilled motivates this PhD thesis „Semi-quantitative X-ray-tomography examinations of biodistribution of magnetic nanoparticles in biological tissues“. The analysis of the distribution of the magnetic nanoparticles in tumours and other tissue examples is realized by means of X-ray-micro computer tomography (XμCT). The work focuses on the quantification of the magnetic nanoparticles in different biological tissue samples by means of XµCT. A calibration of the tomographic devices with adequate phantoms, developed in the frame of this work, opens now the possibility to analyze tomographic data in a semi-quantitative manner. Thus, the nanoparticle concentration can be allocated voxel-wise to the grey values of the three-dimensional tomographic data. With the help of calibration of the tomography equipments used, polychromatic as well as monochromatic three-dimensional representations of objects can be analyzed with regard to the biodistribution of magnetic nanoparticles as well as with regard to their quantity. The semi-quantitative results have been compared with results obtained with a quantitative measurement method magnetorelaxometry (MRX). Thereby a good agreement of the semi-quantitative and quantitative data has been figured out.

Page generated in 0.1627 seconds