• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 149
  • 1
  • Tagged with
  • 151
  • 151
  • 97
  • 87
  • 41
  • 27
  • 23
  • 22
  • 22
  • 19
  • 19
  • 19
  • 19
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Acurária do estudo dos jatos ureterais à ultra-sonografia do Doppler Colorido no diagnóstico das hidronefroses / Diagnostic accuracy of color Doppler sonographic study of the ureteric jets in evaluation of hydronephrosis

Bessa Junior, José de 10 August 2007 (has links)
Introdução e Objetivo: Hidronefrose e Obstrução são condições associadas, entretanto dilatações da via excretora podem ocorrer na ausência de obstruções clinicamente importantes. Ultra-sonografia convencional e Renograma com Diuréticos são os métodos diagnósticos complementares mais utilizados na avaliação das hidronefroses na infância. Recentes trabalhos têm demonstrado a possibilidade de observarmos os jatos ureterais com o Estudo Ultra-sonográfico com Doppler Colorido e sugerido a sua aplicação no diagnóstico diferencial das hidronefroses. O objetivo do presente trabalho foi avaliar a aplicabilidade do estudo dos jatos ureterais como método diagnóstico na identificação das hidronefroses obstrutivas e não obstrutivas na população pediátrica. Métodos: Foram estudadas 48 crianças (35 meninos e 13 meninas) com idade que variou de um mês a 14 anos (mediana de 4 anos), que se apresentaram com Hidronefroses Unilaterais, Graus III e IV, e com suspeita de obstrução da junção pieloureteral. Todos os sujeitos foram submetidos ao Estudo dos jatos ureterais e ao Renograma com Diuréticos num período de duas semanas. As unidades hidronefróticas foram consideradas obstruídas quando a Função Renal Diferencial era menor do que 40%, ou em indivíduos mais velhos que apresentavam dor lombar intermitente. Os jatos ureterais de cada meato foram contados por um período de 5 minutos e considerados separadamente. Freqüência Relativa dos Jatos (FRJ) foi definida como o numero de jatos ureterais no lado afetado dividido pela soma dos jatos ureterais observados bilateralmente. Resultados: Vinte e duas (45,8%) unidades hidronefróticas foram consideradas obstruídas.A média da FRJ diferiu significativamente entre as hidronefroses obstrutivas (0,09 ± 0,15) e não obstrutivas (0,41 ± 0,11). (p<0.001). Análise da Curva ROC revelou que FRJ < 0,25 é o melhor valor que distingue as hidronefroses obstrutivas e não obstrutivas e o faz corretamente em 91,2 % dos casos, com uma Sensibilidade de 86,4% (IC95%=78,6-98,2%) e Especificidade de of 96.15% (IC95%=87.8-99%). O Índice de Probabilidade Positivo foi de 22,45 e a Razão de Chances Diagnóstica de 158,3. A área sob a curva ROC foi de 0,91 (IC95%=0,86-0,98) indicando a excelente acurácia do método. Conclusões: FRJ < 25 % mostrou ser um bom indicador de obstrução nas hidronefroses unilaterais da infância. O estudo dos jatos ureterais a Ultrasonografia com Doppler Colorido é método simples, não invasivo e pode ser utilizado na abordagem inicial e no seguimento, na diferenciação das hidronefroses obstrutivas e não obstrutivas na população pediátrica / Introduction and Objective: Hydronephrosis (HN) and obstruction are closely associated, but upper urinary tract dilatation can occur without significant obstruction. Despite some pitfalls, conventional ultrasonography and diuretic renography (DR) are the main modalities in the evaluation of HN in children. Recent reports have demonstrated the usefulness of Color Doppler Ultrasonography (CDUS) as a reliable method to identify the ureteric jets (UJ) in the bladder. The aim of this study was to evaluate CDUS evaluation of the UJ in the bladder as a diagnostic tool to distinguish obstructive from non-obstructive dilatations of the upper tract in pediatric population. Methods: We evaluated 48 patients (35 boys and 13 girls), aged 1 month to 14 years (median = 4 ys.), who presented with unilateral grade III and IV hydronephrosis suspicious of pyeloureteral junction obstruction. All patients underwent DR and evaluation of UJ by transverse CDSG of the bladder within a maximum of 2 weeks. Obstruction was considered in the DR when the hydronephrotic unit showed Differential Renal Function of less than 40%, or when symptomatic intermittent renal colic was present in older children. The number of UJ was counted over a 5 min period and its frequency was calculated for each ureteral orifice. Relative Jet Frequency (RJF) was defined as the UJ frequency of hydronephrotic side divided by total UJ frequency. Receiver-Operating Characteristic (ROC) plots were constructed to determine the best cuttoff for RJF, in order to identify renal units with obstructive hydronephrosis. Results:Twenty-two(45.8%) hydronephrotic units were considered obstructed. The mean RJF differed significantly between obstructive (0.09 ± 0,15) and non-obstructive hydronephrosis (0.41± 0.11)(p<0.001). ROC analysis revealed that RJF< 0.25 was the best threshold and it correctly discriminates obstruction in 91.2% of the childrens with a sensitivity of 86.4% (95%CI=78.6-98.2%) and specificity of 96.15% (95%CI=87,8-99%). The Positive Likelihood Ratio was 22.45 and Diagnostic Odds Ratio was 158.3.The area under the ROC curve was 0.91 (95%CI=0.86-0.98), indicating excellent discrimination power. Conclusions: In this study RJF < 25% was found to be a good indicator of obstruction in children with unilateral hydronephrosis. CDUS evaluation of UJ is an easy and non-invasive method that can be used as an initial diagnostic tool and in follow-up cases, to differentiate obstructed from non-obstructed hydronephrosis in the pediatric population
92

Resolução Temporal, localização e identificação de sons verbais degradados em portadores de perda auditiva unilateral com e sem dificuldade de linguagem / Temporal resolution, localization and identification of degraded verbal souds in individuals with unilateral hearing loss with and without language difficulty

Nishihata, Regiane [UNIFESP] 24 February 2010 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-02-24 / Objetivos: verificar o comportamento de resolução temporal, de localização sonora e de identificação de sons verbais degradados em indivíduos portadores de perda auditiva unilateral e investigar possíveis associações com a presença ou não de queixas de dificuldades escolares, comunicação e de linguagem. Método. Participaram deste estudo 26 indivíduos, sendo 13 portadores de perda auditiva unilateral, que constituiu o GP e foi subdividido em GPAD (perda auditiva unilateral na orelha direita) e GPAE (perda na orelha esquerda) e 13 ouvintes normais, dos sexos masculino e feminino, com idade entre 8 a 15 anos. Foi realizada anamnese com os pais que responderam um questionário desenvolvido pelas autoras que visa caracterizar o desempenho auditivo, comunicativo e de linguagem, através de dados referentes à idade de suspeita e diagnóstico da perda, fatores de risco auditivos, desenvolvimento de fala e linguagem bem como desempenho escolar. Ainda, foram submetidos à avaliação do Processamento Auditivo por meio dos testes fala com ruído, memória seqüencial verbal e não verbal, localização sonora em cinco direções e teste de detecção de gap randomizado (RGDT). Os dados foram analisados estatisticamente com testes não paramétricos, em um nível de significância de 0.05. Resultados. Não houve diferenças significantes entre o Grupo com Perda Auditiva (GP) e Grupo sem perda auditiva (GSP) na análise do comportamento de resolução temporal medido pelo limiar de acuidade temporal por meio do Teste RGDT. Houve diferenças significantes entre Grupo com Perda Auditiva (GP) e Grupo sem Perda (GSP) na análise de sons degradados por meio do Teste Fala com Ruído. Houve diferenças significantes entre Grupo com Perda Auditiva (GP) e Grupo sem Perda (GSP) na análise do comportamento de localização sonora por meio do Teste de Localização Sonora em cinco direções. O grupo com Perda Auditiva (GP) apresentou maiores índices de dificuldades em seu desempenho auditivo, comunicativo e de linguagem do que as crianças do Grupo Sem Perda Auditiva. Dentro do Grupo com Perda Auditiva (GP) os maiores índices de repetência escolar, freqüência de programa de apoio escolar, problemas comportamentais, atraso de fala e linguagem ocorreram no Grupo com Perda Auditiva à Direita (GPAD). Conclusão: Resolução temporal não distinguiu indivíduos com e sem perda auditiva. Indivíduos com perda auditiva unilateral desempenharam-se pior em tarefas de localização sonora, fechamento e comunicação do que os sem perda auditiva. Grupo com Perda Auditiva Unilateral à direita (GPAD) teve pior desempenho comunicativo, mais atraso de fala ou linguagem e mais problemas comportamentais do que o grupo com perda auditiva à esquerda. / The goal of this research is to verify the temporal resolution , sound localization and identification of degraded verbal sounds in individuals with unilateral hearing loss and investigate possible associations with learning or language disorders. Method: Twenty-six 8 to 15 year-old girls and boys participated in this study .Thirteen had normal hearing ( GSP ).Thirteen had a unilateral hearing loss ( GP ) and were divided into 2 groups: GPAD, with right hearing loss, and GPAE, with left hearing loss . An anamnesis was performed with parents who provided information about child’s auditory, communicative and linguistic behavior as well as performance at school. They informed what the risk factors were, the age of the child when they suspected there might be a hearing loss and the age when the diagnosis was established .The individuals underwent auditory processing assessment with speech in noise tests, sound localization and a gap detection test (RGDT).The data were analyzed with non- parametric tests and a 0.05 significance level. Results. There was no significant difference between the group with hearing loss (GP) and the group without hearing loss (GSP) as to temporal resolution. There was significant difference between the group with hearing loss (GP) and the group without loss (GSP) in degraded sound analysis through speech in noise test. There was significant difference between the group with hearing loss (GP) and the group without loss (GSP) in sound localization in five directions. The group with hearing loss (GP) presented more auditory, communicative and linguistic difficulties than the group without hearing loss. Within the group with hearing loss (GP), the children with right hearing loss ( GPAD ) had a history of speech and language delay, failed at school, attended school remedial programmes , and had behavioural problems more often than GPAE, the children with left hearing loss . Conclusion: Temporal resolution did not distinguish individuals without hearing loss and those with unilateral hearing loss. Individuals with unilateral hearing loss did less well in sound localization and closure tasks and did not communicate as proficiently as those without hearing loss. The Individuals with right hearing loss (GPAD) had often had speech and language delay, academic difficulty, and behavioural problems. / TEDE / BV UNIFESP: Teses e dissertações
93

Acurácia da biópsia incisional por trépano de 2 mm nos tumores palpebrais: estudo comparativo entre um e dois sítios / Accuracy of the 2-mm punch biopsy in eyelid tumors: comparative study between one and two sites

Luiz Angelo Rossato 27 October 2016 (has links)
OBJETIVO: Comparar a acurácia da biópsia incisional em um sítio versus dois sítios, por trépano de 2 mm, em tumores palpebrais como teste diagnóstico do padrão histológico. MÉTODOS: Análise prospectiva das lesões com suspeita de malignidade palpebral no Setor de Plástica Ocular (HC-FMUSP), de novembro de 2012 a dezembro de 2014. As lesões foram fotografadas e suas características clínicas mensuradas por meio do \"software\" ImageJ 1.44. Os pacientes foram aleatoriamente divididos em dois grupos e submetidos à biópsia incisional de forma padronizada com trépano de 2 mm: grupo 1 em um sítio e grupo 2 em dois sítios do tumor. Os resultados diagnósticos das biópsias pré-operatórias foram comparados à peça cirúrgica (padrão-ouro). A avaliação anatomopatológica, tanto da biópsia como do padrão-ouro, foi realizada pelo mesmo médico patologista, e os resultados discordantes revisados por um segundo patologista. As medidas de sensibilidade, especificidade, valor preditivo positivo (VPP) e valor preditivo negativo (VPN), bem como a acurácia e o coeficiente Kappa, foram calculados para avaliar a concordância do diagnóstico da biópsia em relação ao padrão-ouro, comparando-se os dois grupos. Para as variáveis quantitativas, utilizou-se o teste Mann-Whitney, e, para as qualitativas, os testes de qui-quadrado ou exato de Fisher. RESULTADOS: Incluíram-se 166 lesões, sendo 69 no grupo 1 e 97 no grupo 2. O carcinoma basocelular (CBC) representou 63,25% da amostra total. Para todas as variáveis quantitativas e qualitativas, a distribuição entre os grupos foi semelhante e sem diferença estatística. Na identificação do padrão predominante, o grupo 2 apresentou duas vezes mais chance de resultado concordante em relação ao grupo 1, independentemente das demais variáveis: sexo, idade, tempo de evolução (TEV), maior diâmetro, área e margem. Os resultados mostraram melhores índices para o grupo 2, tanto para acurácia e coeficiente kappa quanto para sensibilidade, especificidade, VPP e VPN. A acurácia para diagnóstico do padrão predominante foi, no grupo 1, 53,60% e, no grupo 2, 71,10% com p-valor de 0,021. Em relação aos casos de CBC, a concordância para o subtipo agressivo no grupo 1 foi de 54,50% e, no grupo 2, foi de 73,80%, com diferença significativa (p-valor de 0,041). CONCLUSÕES: A biópsia incisional por trépano de 2 mm em dois sítios dos tumores palpebrais mostrou maior acurácia que em um sítio para o diagnóstico do padrão histológico predominante. Para os casos de CBC, possibilitou melhor diagnóstico do subtipo agressivo / PURPOSE: To compare 2-mm punch biopsy accuracy performed at one site versus two sites to diagnose eyelid tumors histological patterns. METHODS: Prospective analysis of eyelid tumors with suspicion of malignancy conducted at the Ocular Plastic Surgery Center (Hospital das Clínicas, University of São Paulo School of Medicine) from November 2012 until December 2014. Patients were randomly divided into 2 groups, and underwent a 2-mm punch biopsy: group 1 at one site and group 2 at two sites of the tumor. The tumors were photographed and measured with the software Image J 1.44. The results of the preoperative biopsies were compared with the surgical specimens (gold standard). The anatomopathological examination of the biopsy and the surgical specimen was performed by the same pathologist. Discordant results were reviewed by a second pathologist. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy and Kappa coefficients were calculated to determine the agreement between the 2-mm punch biopsy and the gold standard, comparing both groups. The statistical analysis included the Mann-Whitney test for quantitative variables and the chi-square test or the Fisher\'s exact test for qualitative variables. RESULTS: 166 lesions were included, 69 in group 1 and 97 in group 2. Basal cell carcinoma (BCC) accounted for 63.25% of the total sample. For all quantitative and qualitative variables, the distribution between the groups was similar and not statistically significant. In identifying the predominant pattern, biopsy by punch at two sites was two times more likely to agree in relation to one site, regardless of other variables: gender, age, disease duration, largest diameter, area and margin. Results showed higher scores for biopsy at two sites (accuracy, kappa coefficient, sensitivity, specificity, PPV and NPV). For the predominant pattern, the accuracy in group 1 was 53.60% and in group 2 was 71.10% (p = 0.021). Analyzing separately the cases of BCC, agreement for aggressive subtype in group 1 was 54.50% and in group 2 was 73.80%, with statistical difference (p = 0.041). CONCLUSIONS: Two sites of 2-mm punch biopsy in eyelid tumors showed higher accuracy than one site for the diagnosis of predominant pattern. For BCC, it showed better diagnostic results of aggressive subtype
94

Biópsia incisional com trépano de 2 mm em tumores palpebrais / Use of 2-mm punch biopsy in eyelid tumors

Rachel Camargo Carneiro 28 September 2012 (has links)
OBJETIVO: Avaliar a acurácia da biópsia incisional com trépano de 2mm no diagnóstico das tumores palpebrais. Avaliar aeficácia do método nas lesões ulceradas versus não ulceradas; nas lesões marginais da pálpebra versus lesões em outras áreas da pálpebra e na detecção do subtipo histológico do carcinoma basocelular. MÉTODOS: Análise prospectiva das lesões com suspeita de malignidade palpebral no Setor de Plástica Ocular (HC-FMUSP), de maio de 2008 a dezembro de 2011. As lesões foram fotografadas, e suas características clínicas, mensuradas através do softwareImageJ 1.44. O resultado diagnóstico das biópsias pré-operatórias, realizadas de forma padronizada com trépano de 2 mm, foram comparados à peça cirúrgica (padrão-ouro). A avaliação anatomopatológica tanto da biópsia como do padrão-ouro foi realizada de forma mascarada, e os resultados discordantes, revisados por um segundo patologista. As medidas de sensibilidade, especificidade, valor preditivo positivo (VPP) e valor preditivo negativo (VPN), bem como a acurácia e o coeficiente Kappa, foram calculados para avaliar a concordância do trépano de 2 mm em relação ao padrão-ouro. Os testes estatísticos utilizados foram o qui-quadrado, teste t-Student e teste Mann-Whitney para área e tempo de evolução da doença. RESULTADOS: Foram avaliadas 61 lesões. O carcinoma basocelular (CBC) representou 57,4% dos casos. A sensibilidade foi de 87,8%, e a especificidade, de 91,7% para malignidade. O VPP foi de 97,7%, e o VPN, de 64,7%. A acurácia para malignidade foi de 88,5%, sendo a concordância dada pelo Kappa igual a 69,0%. A acurácia para o tipo histológico foi de 83,6 % e, para o subtipo histológico (agrupado) do CBC, foi de 61,3%. Na avaliação do subtipo histológico mais agressivo, a biópsia identificou 61,9%dos casos. Não houve diferença estatística em relação à idade, tempo de evolução da doença, área e maior diâmetro da lesão, tanto em relação à concordância de malignidade quanto ao tipo histológico entre a biópsia e o padrão-ouro (p > 0,05). A ulceração da lesão foi uma variável qualitativa que apresentou significância estatística, sendo que a concordância (malignidade e tipo histológico) foi maior nas lesões não ulceradas (p = 0,035;= 0,042). Lesões em margem, quando comparadas a lesões não marginais, apresentaram estatisticamente maior porcentagem de concordância na biópsia em relação ao padrão-ouro (peça cirúrgica) (p=0,027). CONCLUSÕES: A biópsia incisional por trépano de 2 mm mostrou grande acurácia para confirmação de malignidade palpebral e na identificação do tipo histológico. Entretanto, o procedimento foi menos eficaz para a identificação de subtipo histológico do carcinoma basocelular. O método teve maior concordância nas lesões não ulceradas. A ocorrência de lesões na margem palpebral não influenciou negativamente a acurácia da biópsia por trépano para identificação de malignidade e tipo histológico / Objective: To evaluate the accuracy of 2-mm punch biopsy in the diagnosis of eyelid tumors and evaluate the efficacy of the method in ulcerative vs. nonulcerative tumors, in tumors on the eylid margin vs. other areas on the eyelid, and in the detection of histological subtypes of basal cell carcinoma (BCC). Methods: Prospective analysis of eyelid tumors with suspicion of malignancy conducted at the Ocular Plastic Surgery Center (Hospital das Clínicas, University of São Paulo School of Medicine) between May 2008 and December 2011. The tumors were photographed and measured with the software Image J v. 1.44. The results of the preoperative 2-mm punch biopsies were compared with the surgical specimens (gold standard). The anatomo-pathological examination of the biopsy and the surgical specimen was performed by a blinded pathologist. Discordant results were reviewed by a second pathologist. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy and Kappa coefficients were calculated to determine the agreement between the 2-mm punch biopsy and the gold standard. The statistical analysis included the chi-square test, Studentst test and the Mann-Whitney test for tumor area and duration of disease. Results: Sixty-one tumors were evaluated, 57.4% of which were BCC. Sensitivity and specificity for malignancy were 87.8% and 91.7%, respectively, while PPV was 97.7% and NPV was 64.7%. The accuracy for malignancy was 88.5%, with 69.0% agreement by Kappa analysis. The accuracy for histological type and subtype of BCC was 83.6% and 61.3%, respectively. In the evaluation of the most aggressive subtype, the biopsy identified 61,9% of cases. The variables age, duration of disease and area and largest diameter of tumor were not significantly associated with agreement between the diagnostic methods regarding malignancy or histological type (p>0.05). In contrast, the variable ulceration was significantly associated with agreement between the methods regarding the diagnosis of malignancy (p=0.035) and histological type(p=0.042) in nonulcerative tumors. Likewise, the variable tumor site was statistically significant since the agreement between the methods was greater for tumors on the eyelid margin (p=0.027).Conclusions: Two-millimeter punch biopsy was found to be a very accurate procedure for the determination of eyelidmalignancy and histological type, but less efficient in the identification of subtype. Agreement was best for nonulcerative tumors. The occurrence of tumors on the eyelid margin did not reduce the accuracy of the method for the determination of malignancy and histological type
95

Comparação entre as técnicas de dacriocistografia por ressonância magnética e por raios X no diagnóstico da obstrução das vias lacrimais / Comparison between magnetic resonance and x-ray dacryocystography in the evaluation of the obstruction of the lacrimal apparatus

Luiz de Abreu Júnior 30 July 2008 (has links)
Introdução: Epífora corresponde ao hiperlacrimejamento decorrente de causa obstrutiva. Quase sempre se indica o tratamento cirúrgico, e a determinação do nível e da natureza da obstrução solicita exames de imagem. A ressonância magnética pode ser utilizada nesse contexto. Objetivos: Verificar a eficácia da dacriocistografia por RM, na avaliação de obstrução das vias lacrimais, correlacionando com o exame de imagem padrão-ouro, a dacriocistografia por RX. Métodos: A amostra compreendeu 32 indivíduos (26 mulheres e seis homens, com média de idade de 55,4 ± 21,5 anos) com tempo de sintomatologia oscilando entre três meses e vinte anos. Utilizaram-se seqüências de RM ponderadas em STIR T2 sem e com instilação de soro fisiológico e seqüência gradiente-eco ponderada em T1, após instilação de solução de gadolínio diluído (1:100). Os dados da RM foram correlacionados com o exame padrão-ouro (dacriocistografia por RX). A análise foi realizada por dois observadores. Foram calculados: a sensibilidade, a especificidade e os valores preditivos - positivo (VPP) e negativo (VPN) - de cada uma das seqüências de RM, para a detecção da presença de obstrução das vias lacrimais. Calculou-se, ainda, a concordância intra- e interobservador para os diagnósticos da presença e do nível da obstrução, obtidos em cada seqüência de RM, comparando-a com o padrão-ouro (DCG), utilizando-se o teste exato de Fischer e o índice Kappa (K), com nível de significância (p) < 0,001. Resultados: Quanto à detecção de obstrução das vias lacrimais, as seqüências de RM apresentaram sensibilidade entre 91,9% e 93,2%, especificidade entre 80,3% e 100%, VPP entre 88,7% e 100% e VPN entre 83,2% e 87,8%. O índice Kappa revelou concordâncias intra- e interobservadores bastantes elevadas (entre 0,716 e 1,000). Quanto à caracterização do nível da obstrução, houve diferenças entre os resultados de cada um dos observadores. Para o observador 1, apenas a seqüência STIR, com instilação de soro fisiológico, denotou concordância estatisticamente significante com a DCG (K = 0,582). Em contrapartida, para o observador 2, todas as seqüências de RM mostraram concordância estatisticamente significante com a DCG (K entre 0,404 e 0,623). Conclusões: A RM pode ser adotada como método de imagem para a avaliação dos pacientes com suspeita de obstrução das vias lacrimais, por apresentar elevada sensibilidade e especificidade para esse diagnóstico, além de elevados índices de concordância intra - e interobservadores. Nos casos em que as vias lacrimais se revelem não preenchidas por qualquer meio de contraste na RM, outros métodos de imagem poderão ser necessários para a diferenciação entre obstruções altas ou distúrbios funcionais / Epiphora is the hyperlachrymation related to an obstruction of the lachrymal drainage system. In such cases, the treatment is frequently surgical and the definition of the nature and level of obstruction demands imaging methods. Magnetic Resonance Imaging (MRI) may play a role in this issue. Objectives: Evaluate the efficacy of MR dacryocystography in the obstruction of the lachrymal drainage system, comparing the results to the gold standard imaging method (X-ray dacryocystography - DCG). Methods: The study comprised 32 patients (26 women and 6 men, mean age 55.4 ± 21.5 years), with a time course of symptoms ranging from 3 months to 20 years. They were evaluated using a STIR T2 sequence, without and with the instillation of saline solution and a Gradient-echo T1 sequence after instillation of 1:100 diluted gadolinium. The MRI findings were compared to the DCG ones. Two different observers performed the analysis. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each MRI sequence, regarding the detection of the obstruction of the lachrymal apparatus. Intra and interobserver agreement were calculated for the detection of the obstruction and for the determination of the level of obstruction, using the Fischer exact test and Kappa index - K (statistical significance p < 0,001). Results: Regarding the detection of obstruction, MRI sequences presented sensitivity ranging from 91.9% to 93.2%, specificity ranging from 80,3% to 100%, PPV ranging from 88.7% to 100% and NPV ranging from 83.2% to 87.8%. Kappa index revealed high intra and interobserver values (ranging from 0.716 to 1.000). Regarding the determination of the level of obstruction, the results for each observer were different. For Observer 1, the STIR T2 sequence after instillation of saline solution was the only one to be statistically concordant to DCG (K = 0.582). Otherwise, for Observer 2, all MR sequences were statistically concordant to DCG (K ranging from 0.404 to 0.623). Conclusions: MRI may be considered in the radiological evaluation of patients with epiphora, due to its high sensitivity and specificity, as well as consistent intra and interobserver agreement rates. When the lachrymal drainage system is not filled with any kind of content in the MRI examination, other imaging modalities must be considered, for differentiation between upper system obstruction and functional disease
96

Contribuição da ultra-sonografia no diagnóstico da doença do refluxo gastroesofágico em crianças: estudo comparativo com pHmetria e histopatologia / An ultrasonographic contribution on the diagnosis of gastroesophageal reflux disease in children: a comparative study with pH monitoring and histopathology

Telma Sakuno 11 September 2006 (has links)
INTRODUÇÃO: O refluxo gastroesofágico (RGE) é a passagem involuntária do conteúdo gástrico para a luz do esôfago. É uma condição comum nos lactentes e crianças menores, sendo, na maioria das vezes, considerado fisiológico, no entanto, pode determinar manifestações clínicas e levar à doença do refluxo gastroesofágico (DRGE). O objetivo deste estudo foi avaliar a ultra-sonografia como meio diagnóstico da DRGE, comparando-a com a pHmetria e histopatologia nos pacientes acima de dois anos de idade. MÉTODO: Foram avaliadas 45 crianças, com idade entre dois e 14 anos, com suspeita clínica de RGE por meio da ultra-sonografia, pHmetria e endoscopia digestiva alta com biópsia. As variáveis estudadas foram a presença do refluxo gastroesofágico, a medida do ângulo de His, o comprimento do esôfago intra-abdominal, o número e tempo de duração do RGE, presença de esofagite e hérnia hiatal. Na análise estatística, calculouse a sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo, com p<0,05. Aplicou-se a regressão logística para estimar o desfecho DRGE e esofagite. RESULTADOS: A ultra-sonografia apresentou sensibilidade de 91,7%, especificidade de 61,9%, valor preditivo positivo de 73,3% e valor preditivo negativo de 86,7% para o diagnóstico da DRGE quando comparada à pHmetria. Na análise univariada o ângulo de His mostrou-se o preditor com melhor especificidade para o desfecho DRGE e esofagite, 71,4% e 72,7%, respectivamente. CONCLUSÃO: A ultrasonografia mostrou-se um exame não invasivo, de baixo custo e preciso na avaliação da junção esofagogástrica, a sua alta sensibilidade e boa especificidade quando comparada à pHmetria, permite o seu emprego na avaliação inicial da criança com suspeita de DRGE / INTRODUCTION: Gastroesophageal reflux (GER) is an involuntary passage of the gastric content to the esophagus. Most of the time, it is considered a physiologic condition as it is very common on breast feeding babies and small children, however, it may determine clinical manifestations and lead to gastroesophageal reflux disease (GERD). The aim of this study was to evaluate ultrasonography as a mean of GERD diagnosis, comparing it with pH monitoring and histopathology in patients older than 2 years of age. METHOD: 45 children aged 2 to 14 years old were evaluated, who had been clinically suspected with GER were submitted to ultrasonography, pH monitoring and upper endoscopy with biopsy. Variables for this study were the presence of gastroesophageal reflux, angle of His measurement, length of intra-abdominal esophagus, time duration and frequency of GER, presence of oesophagitis and hiatus hernia. The statistical analysis measured the sensibility, specificity, positive and negative predictive values considering p<0.05. Logistic regression was applied to estimate GERD outcome and oesophagitis. RESULTS: Ultrasonography results showed sensibility of 91.7%, specificity of 61.9%, and positive predictive value of 73.3% and negative predictive value of 86.7% for the diagnosis of GERD when compared to pH monitoring. In the single variable analysis, the angle of His showed to be the predictor with best specificity for GERD and oesophagitis outcome, 71.4% and 72.7%, respectively. CONCLUSION: Ultrasonography showed to be a harmless exam with low costs and precise in the assessment of the esophagi-gastric junction, and its high sensibility and good specificity when compared to pH monitoring allows it to be performed in the early evaluation of children suspected with GERD
97

Correlação do diagnóstico pré e pós videolaparoscópico de pacientes submetidas a procedimento cirúrgico / Correlation between pre- and post-operative diagnosis in patients undergoing videolaparoscopic surgery

Argentino, Gislaine Laperuta Serafim [UNESP] 29 August 2017 (has links)
Submitted by GISLAINE LAPERUTA SERAFIM ARGENTINO null (giserafim@yahoo.com.br) on 2017-10-18T13:16:59Z No. of bitstreams: 1 Dissertação Mestrado Gislaine Publicaçao.pdf: 5703913 bytes, checksum: c9ee15cb3dfd3bc350df78bce43ea2b8 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-10-23T18:49:08Z (GMT) No. of bitstreams: 1 argentino_gls_me_bot.pdf: 5703913 bytes, checksum: c9ee15cb3dfd3bc350df78bce43ea2b8 (MD5) / Made available in DSpace on 2017-10-23T18:49:08Z (GMT). No. of bitstreams: 1 argentino_gls_me_bot.pdf: 5703913 bytes, checksum: c9ee15cb3dfd3bc350df78bce43ea2b8 (MD5) Previous issue date: 2017-08-29 / Objetivo: Avaliar a concordância entre o diagnóstico ginecológico pré- e pós-laparoscópico, a fim de verificar se existem diferenças consideráveis na confirmação diagnóstica utilizando técnica cirúrgica minimamente invasiva. Métodos: Estudo descritivo retrospectivo de levantamento de prontuários com amostra de conveniência. Foi realizada análise comparativa de dados referentes ao diagnóstico clínico de 315 pacientes submetidas a procedimento cirúrgico laparoscópico no Setor de Endoscopia Ginecológica e Planejamento Familiar da Faculdade de Medicina de Botucatu – FMB/UNESP entre o período de março de 2010 a outubro de 2016. A comparação entre os diagnósticos pré- e pós-operatório foi realizada pelo teste de concordância considerando as proporções de ocorrências. Resultados: A laparoscopia auxiliou na elucidação diagnóstica de 59,6% dos casos de infertilidade (P>0,05) e de 93,7% dos casos de dor pélvica crônica de causa indeterminada (P<0,01), além de ser conclusiva na elucidação do diagnóstico de abdômen agudo e na exclusão de abscesso tubo-ovariano (P<0,05). A laparoscopia, ainda, aumentou em 76,7% o diagnóstico de aderências pélvico-abdominais (P>0,05). Conclusão: O uso da laparoscopia demonstrou diferenças consideráveis na confirmação diagnóstica, notadamente nos casos de dor pélvica crônica de etiologia indeterminada. / Objective: To evaluate the concordance between the pre and post-laparoscopic gynecological diagnosis in order to verify if there are considerable differences in the diagnostic confirmation using a minimally invasive surgical technique. Methods: Retrospective descriptive study of a survey of medical reports with convenience sample. It was made a comparative analysis of data referring the clinical diagnosis of 315 patients submitted to laparoscopic surgical procedure in the Gynecological Endoscopy and Family Planning Section of Botucatu Medical School - FMB / UNESP between March 2010 and October 2016. The comparison between the pre- and postoperative diagnoses was made by the concordance test considering the proportions of occurrences. Results: Laparoscopy assisted in the diagnostic elucidation of 59.6% of infertility cases (P>0.05) and 93.7% of cases of chronic pelvic pain of indeterminate cause (P<0.01), besides being conclusive in the elucidation of the diagnosis of acute abdomen and in the exclusion of tube-ovarian abscess (P<0.05). Laparoscopy also increased the diagnosis of pelvic-abdominal adhesions (P>0.05) in 76.7%. Conclusion: The use of laparoscopy demonstrated considerable differences in diagnostic confirmation, especially in cases of chronic pelvic pain of undetermined etiology.
98

Avaliação da audição residual em candidatos  a implantes coclear atráves da resposta  auditiva de estado estável / Evaluation of residual hearing in cochlear implants candidates using auditory steady-state response

Henrique Faria Ramos 02 April 2013 (has links)
INTRODUÇÃO: A identificação e preservação da audição residual em candidatos a implante coclear vêm assumindo maior importância clínica. A resposta auditiva de estado estável (RAEE) pode fornecer informação frequência-específica sobre o limiar auditivo em níveis de intensidade máximos de 120 dB NA, possibilitando a investigação da audição residual. Os objetivos deste estudo são avaliar a audição residual em candidatos a implante coclear, comparando os limiares eletrofisiológicos da RAEE com os limiares psicoacústicos da audiometria nas frequências de 500, 1 000, 2 000 e 4 000 Hz. MÉTODO: Foram avaliados 40 candidatos a implante coclear (80 orelhas) com perda auditiva neurossensorial severa a profunda bilateral. A audiometria foi realizada com o tom \"warble\" nas frequências de 500, 1 000, 2 000 e 4 000 Hz com intensidade máxima de estimulação de 120 dB NA. A RAEE foi obtida através da estimulação dicótica de uma frequência de tons contínuos sinusoidais modulados 100% em amplitude exponencial e 20% em frequência, nas frequências portadoras de 500, 1 000, 2 000 e 4 000 Hz, com estimulação máxima de 117, 120, 119 e 118 dB NA, respectivamente. RESULTADOS: Foram obtidos limiares mensuráveis em 62,5% de todas as frequências estudadas na audiometria tonal e em 63,1% na RAEE. A RAEE apresentou sensibilidade de 96% e especificidade de 91,6% na detecção da audição residual. As diferenças médias entre os limiares da audiometria tonal e da RAEE não apresentaram significância estatística em nenhuma das frequências. As correlações entre os limiares comportamentais e da RAEE foram significantes em todas as frequências avaliadas, sendo fortes em 500, 1 000 e 2 000 Hz e moderada em 4 000 Hz, com coeficiente de correlação de Pearson entre 0,65 e 0,81. Em 90% dos casos, os limiares da RAEE foram adquiridos nos limites de 10 dB dos limiares comportamentais. CONCLUSÕES: As correlações entre os limiares tonais e da RAEE foram significantes nas frequências de 500, 1 000, 2 000 e 4 000 Hz. A RAEE apresentou alta sensibilidade e especificidade na detecção da audição residual em candidatos a implante coclear, em comparação com a audiometria tonal / INTRODUCTION: Identification and preservation of residual hearing in cochlear implantation are becoming more important lately. Auditory steadystate response (ASSR) can provide frequency-specific information regarding the auditory thresholds at maximum intensity levels of 120 dB HL, allowing investigation of residual hearing. The study objectives are to assess residual hearing in cochlear implant candidates by comparing the electrophysiological thresholds obtained in ASSR with psychoacoustic thresholds of audiometry at 500, 1 000, 2 000 and 4 000 Hz. METHOD: Forty cochlear implant candidates (80 ears) with bilateral severe-to-profound sensorineural hearing loss were studied. Warble-tone audiometry was performed at the frequencies 500, 1 000, 2 000 e 4 000 Hz, with stimuli up to 120 dB HL. ASSR was obtained with dichotic single-frequency stimulation of sinusoidal continuous tones modulated in exponential amplitude of 100% and in frequency of 20%, at the carrier frequencies of 500, 1 000, 2 000 and 4 000 Hz at maximum stimulation levels of 117, 120, 119 and 118 dB HL, respectively. RESULTS: Thresholds were obtained in 62,5% of all frequencies evaluated in warbletone audiometry and in 63,1% in the ASSR. ASSR showed sensitivity of 96% and specificity of 91,6% in the detection of residual hearing. The mean difference between the thresholds of behavioral audiometry and ASSR were not statistically significant in any of the frequencies. Strong correlations between behavioral and ASSR thresholds were observed in 500, 1 000 and 2 000 Hz and moderate in 4 000 Hz, with Pearson correlation coefficient between 0,65 and 0,81. In 90% of the occasions, ASSR thresholds were within 10 dB of behavioral thresholds. CONCLUSIONS: The correlations between behavioral and ASSR thresholds were significant at 500, 1 000, 2 000 and 4 000 Hz. ASSR showed high sensitivity and specificity in the detection of residual hearing in cochlear implant candidates, compared to warble-tone audiometry
99

Análise da eficiência da PCR com identificação específica do agente etiológico para o diagnóstico da Leishmaniose Visceral Canina / Evaluation of PCR techniques for the identification and characterization of Visceral Leishmaniasis in different tissues of seropositive dogs

Thaynan Fernandes Cunha Martins 18 November 2013 (has links)
Atualmente, um dos grandes problemas relacionados à leishmaniose é a falta de um diagnóstico específico capaz de indentificar e diferenciar espécies de Leishmania com rapidez e precisão. O desenvolvimento de métodos moleculares como a Reação em Cadeia da Polimerase (PCR), possibilita que o diagnóstico da Leishmaniose Visceral Canina (LVC) possa se tornar mais preciso e, eventualmente, de fácil execução, uma vez que limitações importantes relacionadas à sensibilidade e especificidade desta técnica ainda são descritas, principalmente quando se utiliza amostras clínicas. Com o intuito de melhor avaliar a eficiência da PCR para o diagnóstico da LVC, foram selecionadas diferentes amostras clínicas (baço, aspirado de linfonodo, pele sem lesão, pele com lesão e amostras de sangue) de 26 cães com sorologia positiva para leishmaniose submetidos à eutanásia pelo Serviço de Vigilância Epidemiológica do município de Embu das Artes - SP. Realizamos uma análise comparativa entre a PCR-RFLP kDNA-HaeIII e PCR-RFLP hsp70-BsaJI/EcoRII com dois métodos diagnósticos tradicionais (parasitológico direto, e cultura in vitro). Amostras clínicas de 28 cães com sorologia negativa para LVC da mesma região foram utilizadas como controle negativo das reações. Notamos que a PCR aprensentou maior sensibilidade em todas as amostras clínicas testadas quando comparadas aos métodos tradicionais. Os resultados apontam que a PCR-RFLP kDNA-HaeIII é a mais eficiente para o diagnóstico da LVC, com um índice de 96,15% de positividade nas amostras de pele com lesão. Quanto à discriminação da espécie de Leishmania envolvida na infecção, nossos resultados de PCR-RFLP kDNA-HaeIII indicam Leishmania chagasi-infantum como o agente etiológico envolvido na infecção e transmissão canina na cidade de Embu das Artes. Por outro lado, a análise da PCR em Tempo Real (qPCR), mostrou que algumas amostras de sangue não apresentavam o padrão associado à Leishmania chagasi-infantum, podendo indicar uma co-infecção com outras parasitoses caninas. Nosso grupo também acompanhou 184 crianças de 4 a 10 anos de idade (população de risco) residentes da mesma região de transmissão autóctone da doença canina, como também foi realizado um levantamento das espécies de flebotomíneos da região (pela SUCEN). Até o momento, não foi encontrado nenhum caso da doença humana, nem a principal espécie transmissora do parasito (Lutzomiya longipalpis). Acreditamos que esses resultados possam contribuir significativamente para aprimorar o diagnóstico e a identificação das espécies Leishmania na LVC. / Currently, one of the major problems related to leishmaniasis is the lack of a specific diagnosis capable of identifying and differentiating Leishmania species quickly and accurately. The development of molecular methods such as Polymerase Chain Reaction ( PCR ) allows the diagnosis of Canine Visceral Leishmaniasis (CVL) to become more accurate and eventually, easy to perform, since that important limitations in terms of sensitivity and specificity of this technique are being described especially when using clinical samples. In order to better evaluate the efficiency of PCR for the diagnosis of CVL, we selected different clinical samples (spleen, lymph node aspirate, skin with and without lesions and blood samples) from 26 dogs with positive serology for leishmaniasis submitted to euthanasia by the Agency of Epidemiological Surveillance of Embu das Artes - SP. Therefore, we performed a comparative analysis between the kDNAPCR-RFLP HaeIII and hsp70PCR-RFLP BsaJI/EcoRII with two traditional diagnostic methods (direct parasitological test, and in vitro culture). Additionally, clinical samples from 28 dogs with negative serology for CVL in the same region were used as negative reactions control. We noted that the PCR showed greater sensitivity in all clinical samples tested when compared with traditional methods. The results indicate that the kDNAPCR-RFLP HaeIII is the most efficient test for the diagnosis of CVL, with a positivity index of 96.15 % in skin lesions samples. Related to the discrimination of the Leishmania species involved in the infection, our results of kDNAPCR-RFLP HaeIII indicate Leishmania infantum chagasi as the agent involved in canine infection in Embu das Artes city. Moreover, the analysis of real-time PCR (qPCR) showed that some blood samples has not showed the same pattern associated with Leishmania infantum chagasi suggesting a possible co-infection with other canine parasite. Our group also followed 184 children between 4 to 10 years old (risk population) living in the same region of autochthonous transmission of canine disease, as well a survey was conducted on the sandfly species in the region (by SUCEN). So far, we found no human infection, nor the main species involved in the transmission of the parasite (Lutzomyia longipalpis). We believe that these results can significantly contribute to the improvement of the diagnosis and identification of Leishmania species involved in the CVL worldwide.
100

Reação em cadeia da polimerase em amostras de linfa coletadas em papel filtro no diagnóstico da hanseníase / Polymerase chain reacton using lymph smear stored in filter paper in leprosy diagnosis

Victor Hugo Damasceno Fernandes 16 July 2018 (has links)
O diagnóstico etiológico da hanseníase, causada pelo bacilo Mycobacterium leprae, pode ser difícil na forma paucibacilar (PB), na qual os exames têm baixa sensibilidade na detecção do bacilo. A reação em cadeia da polimerase (PCR) tem se mostrado sensível para o diagnóstico da hanseníase. Amostras de linfa são rapidamente obtidas em campo e pouco invasivas. O objetivo principal deste trabalho foi comparar os resultados da PCR com 4 pares de primers (Ag85B, MntH, Pra-36kDa e RLEP), descritos na literatura para o diagnóstico da hanseníase, utilizando-se DNA extraído de amostras de linfa de orelhas, cotovelos e joelhos, coletadas em papel filtro. Além da comparação dos resultados da PCR com os 4 pares de primers, também foram comparados à baciloscopia de linfa no grupo MB e ao ELISA anti-PGL-1 nos grupos PB e MB, utilizando-se o teste de qui-quadrado de McNemar para amostras pareadas. Trinta e nove pacientes com hanseníase [12 (30,76%) na forma PB e 27 (69,23%), multibacilar (MB)], virgens de tratamento, atendidos consecutivamente no período de 2006 a 2010, foram incluídos. A detecção de bacilos à baciloscopia e na biópsia de pele foi confirmada em 55,55% e em 100% dos pacientes MB, respectivamente; e 67,56% dos pacientes (33,33% dos PB e 84% dos MB) apresentaram títulos de anti-PGL1 acima do cut-off no ELISA. A PCR foi positiva em 70,37% das 27 amostras de pacientes MB, considerando-se o resultado conjunto dos 4 primers (7,69% com Ag85B; 11,11% com MntH; 12,5% com Pra-36kDa; e 66,66% com RLEP). Uma amostra se mostrou positiva com os primers Ag85B, MntH e Pra-36kDa e negativa com RLEP. Não houve amplificação no grupo PB, portanto, os resultados do ELISA anti-PGL-1, embora não confirmatórios da etiologia, foram superiores para o diagnóstico da hanseníase PB. No grupo MB, os resultados da PCR com RLEP foram superiores àqueles com MntH, Ag85B e Pra- 36kDa (P<0,001); comparando-se MntH com Ag85B e Pra-36kDa (P=0,317; P=1,0, respectivamente), e Ag85B com Pra-36kDa (P=0,564), os resultados foramsemelhantes. A frequência de positividade da baciloscopia foi maior que a da PCR com MntH (P=0,001), Ag85B (P<0,001) e Pra-36kDa (P=0,004); semelhante ao RLEP (P=0,083); e menor, quando comparada ao resultado combinado dos 4 primers (P=0,046). Ainda no grupo MB, a frequência de positividade anti-PGL-1 foi superior à da PCR com MntH, Ag85B e Pra-36kDa (P<0,001) e à baciloscopia (P=0,011); porém, foi semelhante à PCR com RLEP (P=0,059) ou com os 4 primers combinados (P=0,102). A maior frequência de positividade da PCR com primers RLEP é explicada pela presença de múltiplas cópias RLEP no genoma do bacilo, aumentando a chance do anelamento e amplificação. Existe complementariedade entre os resultados com diferente primers, podendo uma mesma amostra apresentar diferentes resultados a depender da escolha destes. A frequência da positividade da PCR com par de primers RLEP, em amostras de linfa coletadas em papel filtro, mostrou-se semelhante à da baciloscopia e do ELISA anti-PGL-1 nos pacientes MB. Assim, encoraja-se seu emprego em trabalhos de campo devido à facilidade da coleta e possibilidade de remessa dos papéis filtro para centros de referência. / Leprosy\'s etiologic diagnosis may be difficult in paucibacillary (PB) patients, in which laboratory tests have low sensitivity for the detection of the causative agent, Mycobaterium leprae. Polymerase chain reaction (PCR) has shown good sensitivity in leprosy diagnosis. Lymph samples are readily acquired in the field and minimally invasive. The main objective of this paper is to compare the results of PCR with four sets of primers previously described in the literature (Ag85B, MntH, Pra-36kDa and RLEP), using DNA extracted from lymph samples from ear lobes, elbows and knees, stored in filter paper. We also aim to compare the PCR results to lymph bacilloscopy in the multibacillary (MB) group and to anti-PGL-1 serology in PB and MB group, using McNemar\'s chi-square test for paired samples. 39 treatment-naïve leprosy patients [12 (30.76%) PB and 27 (69.23%) MB] seen in the outpatient clinic of a referral center were included. Bacilli were detected in 55.55% of bacilloscopy samples and 100% of biopsies from MB patients; 67.56% of all patients (33.33% of PB and 84% of MB) had anti-PGL1 titers above the method\'s cut-off. PCR was positive in 70.37% of the 27 MB patients, taking in consideration the 4 primers combined (7,69% with Ag85B; 11,11% with MntH; 12,5% with Pra-36kDa; e 66,66% with RLEP). One sample was positive for primers Ag85B, MntH e Pra-36kDa and negative for RLEP. There was no DNA amplification in the PB group, in which antiPGL-1 ELISA, although not confirmatory of the disease, was superior in the diagnosis. In the MB group, PCR with RLEP primer was superior to Ag85B, MntH and Pra-36kDa (P<0,001); between MntH and Ag85B (P=0,317); MntH and Pra- 36kDa (P=1,0); and Ag85B and Pra-36kDa (P=0,564), results were similar. Bacilloscopy\'s frequency of positivity was greater than PCR with Ag85B (P<0,001), MntH (P=0,001) and Pra-36kDa (P=0,004); similar to RLEP (P=0,083); and inferior to the results of the four primers combined (P=0,046). Still in the MB group, anti-PGL-1 serology was superior to PCR with Ag85B, MntH and Pra-36kDa (P<0,001) and to bacilloscopy (P=0,011); its results were similar to PCR with RLEP (P=0,059) or with the four primers combined (P=0,102). RLEP\'s greater positivity is probably due to thepresence of multiple copies of the target DNA in the bacillus\' genome, enhancing the chances of primer annealing. The primers showed complementarity; therefore one sample may display different outcomes depending on primer choice. The frequency of positivity of PCR with RLEP primers, in lymph samples stored in filter paper, was similar to bacilloscopy and serology amongst MB patients. Hence, we encourage its use in fieldwork as a practical and easy method for acquiring samples that can be shipped for further processing in referral centers.

Page generated in 0.0965 seconds