• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 560
  • 51
  • 26
  • 13
  • 1
  • 1
  • Tagged with
  • 654
  • 548
  • 183
  • 181
  • 181
  • 119
  • 93
  • 83
  • 73
  • 57
  • 46
  • 46
  • 46
  • 46
  • 40
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

Contribuição ao estudo de reações mediadas por calcogenetos Zn e Cu: hidrocalcogenação de ácidos e ésteres e síntese de sulfetos arílicos / New contributions for the synthesis of unsymmetrical diaryl thioethers and vinyl chalcogenides compunds promoted by copper Senelenophene-2-carboxylate and zinc chalcogenolates

Nunes, Vanessa Loren 04 May 2012 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2014-09-18T18:51:43Z No. of bitstreams: 2 Dissertação Vanessa Loren Nunes.pdf: 10979785 bytes, checksum: 8efff856842f8d2962b9f8221ec1fcb5 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2014-09-19T11:28:41Z (GMT) No. of bitstreams: 2 Dissertação Vanessa Loren Nunes.pdf: 10979785 bytes, checksum: 8efff856842f8d2962b9f8221ec1fcb5 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-09-19T11:28:41Z (GMT). No. of bitstreams: 2 Dissertação Vanessa Loren Nunes.pdf: 10979785 bytes, checksum: 8efff856842f8d2962b9f8221ec1fcb5 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2012-05-04 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / This work describes some studies on the preparation of unsymmetrical diaryl thioethers catalyzed by Copper(I)-Senelenophene-2-carboxylate. The results concern to the catalyzed cross-coupling reaction between aryl halides and aryl or alkylthiols using Copper(I)-Senelenophene-2-carboxylate (CuSC) a new Cu-catalyzed one-pot protocol. The products were obtained in good to excellent yields under relatively mild reaction conditions presenting chemoselectivity and functional group tolerance. Additionally, we have developed a chemio-, regio and stereoselective synthesis of vinyl chalcogenides compounds promoted by zinc chalcogenolates. In this protocol the reductive cleavage of chalcogen bond by the Zn/NH4OH system led to zinc chalcogenolates. The reaction was carried out with acids and esters propiolics afford β-chalcogenacrillic acids and esters under mild and basic conditions. The stereochemistry corresponding to anti-Markovnikov addition of the chalcogenolate constituents across the triple bond were obtained in good yields. / Este trabalho descreve o estudo das reações de acoplamento cruzado entre iodetos arílicos e tióis arílicos ou alquílicos catalisada por 2-carboxilato selenofeno de cobre (I) (CuSC). Apresentamos uma nova metodologia “ one pote” para a síntese de tioésteres arílicos obtidos em condições reacionais relativamente brandas, apresentando quimiosseletividade, tolerância a diversos grupos funcionais e rendimentos que variam entre bons a ótimos (70-100%). R1I + R2SH K3PO4, DMSO S R1 R2 Adicionalmente, desenvolvemos uma síntese quimio, régio, e estereosseletiva de compostos vinil calcogenetos promovida por calcogenolato de zinco. Neste protocolo a clivagem redutiva da ligação calcogênio feita pelo sistema Zn/NH4OH obteve os calcogenolatos de zinco. A reação foi realizada com ácidos e ésteres propiólicos formando ácidos acrílicos β-calcogênio e ésteres sob condições básicas e brandas. A estereoquímica corresponde a adição anti-Markovnikov dos constituintes calcogenolatos através da ligação tripla. Os calcogenetos vinílicos foram obtidos em bons rendimentos (40-96).
292

Estudo comparativo das técnicas de micro resíduo de carbono (ASTM D4530) e termogravimetria na análise de biodiesel / Comparative study of techniques of micro residue of carbon (ASTM 4530) and termogravimetry in biodiesel analysis

Franco, Pedro Ivo Brandão e Melo 30 May 2012 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2014-09-26T18:06:22Z No. of bitstreams: 2 Dissertação_PIBMF_Corrigida.pdf: 1135541 bytes, checksum: abeaf5cd4791754623b20793845be1d8 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-09-26T18:11:48Z (GMT) No. of bitstreams: 2 Dissertação_PIBMF_Corrigida.pdf: 1135541 bytes, checksum: abeaf5cd4791754623b20793845be1d8 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-09-26T18:11:48Z (GMT). No. of bitstreams: 2 Dissertação_PIBMF_Corrigida.pdf: 1135541 bytes, checksum: abeaf5cd4791754623b20793845be1d8 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2012-05-30 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / The thermogravimetry has emerged to be an alternative technique for the analysis of biodiesel due to the rapidly methods, sensitivity and accuracy. Because of different characteristics between biodiesel and petroleum products, is difficult to adapt standard methods as in many cases the result dimension is quite distinct by capability of equipment detection. The micro residue of carbon test is one of the techniques which do not accomplish the biodiesel requirements. There is a deviation between national legislation and stipulated technical standard, thru ASTM D4530 for petroleum samples, the test should be applied with the residual of 0,10% (w/w) once previously distilled to remove 90% (v/v) of the total volume. Therefore thermogravimetry turn as an alternative for essay of micro carbon residue based on the results of this study which perform in biodiesel analysis and it has several advantages. / Com a necessidade de metodologias mais rápidas, mais sensíveis e mais precisas, a termogravimetria desponta como uma forte alternativa para a análise de biodiesel. Devido à diferença entre a natureza do biodiesel e a dos produtos de petróleo é difícil à adaptação dos métodos padrões, já que em muitos casos a magnitude do resultado é bem distinta da capacidade de detecção do método do equipamento utilizado. O teste de micro resíduo de carbono pertence a esse grupo de técnicas as quais não satisfazem os requerimentos do biodiesel. Existindo divergências entre a legislação nacional e o estipulado pela norma técnica, deve-se ter em conta que apesar da norma ASTM D4530 ser aplicável a produtos de petróleo, ela considera que a análise pode ser feita para amostras que apresentem valores de resíduo abaixo de 0,10 % (m/m), devendo-se apenas, destilar previamente amostra para remover 90 % (v/v) do volume total. Com isso a Termogravimetria se apresenta como uma alternativa na execução do ensaio de micro resíduo de carbono e com base nos resultados apresentados neste trabalho ela se mostrou capaz de realizar a análise de micro resíduo de carbono em biodiesel, além de apresentar diversas vantagens perante o método atualmente utilizado.
293

Síntese, caracterização e estudo das propriedades magnéticas de CoFe(2-x)YxO4, 0≤x≤0,05, produzidas por reação de combustão / Synthesis, characterization and studies of magnetic properties of CoFe(2-x)YxO4, 0≤x≤0,05, produced by combustion reaction

Nascimento, Thaísa Cardoso 23 July 2013 (has links)
Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-09-26T20:05:43Z No. of bitstreams: 2 Nascimento, Thaísa Cardoso-2013-dissertação.pdf: 5562960 bytes, checksum: 3da89e8903269de85813600afded8dde (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-09-26T20:05:53Z (GMT) No. of bitstreams: 2 Nascimento, Thaísa Cardoso-2013-dissertação.pdf: 5562960 bytes, checksum: 3da89e8903269de85813600afded8dde (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-09-26T20:05:53Z (GMT). No. of bitstreams: 2 Nascimento, Thaísa Cardoso-2013-dissertação.pdf: 5562960 bytes, checksum: 3da89e8903269de85813600afded8dde (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2013-07-23 / Compounds of CoFe(2-x)YxO4, with 0 x 0.05, were synthesized by combustion reaction. On the synthesis we used as oxidizing reagents, iron nitrate Fe(NO3)3.9H2O, cobalt nitrate Co(NO3)2.6H2O, yttrium nitrate Y(NO3)3.6H2O and as a fuel reducer, was used urea CO(NH2)2 with 300% in excess. Post nanometric of cobalt ferrite in the spinel structure was obtained, wich formed crystalline aggregates, with crystallite average size of 20 ± 3 nm. The results of X-ray diffraction showed well defined diffraction peaks characteristic of the pure phase CoFe2O4, not showing secondary phase for all the compounds stoichiometries. The infrared spectra showed bands characteristic of the metal and the oxygen bonds in the octahedral and tetrahedral sites around 590-600 cm-1 and 400 cm-1 respectively, as well as, shifting of the same to higher frequencies, also showed bands relating to residual compounds bonds of the synthesis stage, that was eliminated during the heating to obtain the thermograms. The thermograms showed the material chemical stability and the residual compounds elimination and the crystallization of the same starting at 400°C. The micrographs achieved through transmission electron microscopy showed crystalline agglomerates and using the program Image J. was possible to make 301 counts of the particles diameters and to obtain a mean value for the sample x = ~ 1.5% of 18.58 nm, close to that obtained by the Scherrer equation, which for this sample was ~19 nm. The scanning electron microscopy via Energy Dispersive Spectrometer (EDS) was used to determine the chemical composition of the experimental material, and along with the stoichiometric calculate the values were tabulated. The data exposed in the table showed an agreement with the calculated values whit the obtained. The magnetic analysis revealed that the samples show the typical ferrimagnetism of the compound nature dependent of the Y3+ concentration. / Compostos de CoFe(2-x)YxO4, com 0 x 0,05, foram sintetizados por reação de combustão. Na síntese foram empregados como reagentes oxidantes; nitrato de ferro, Fe(NO3)3.9H2O, nitrato de cobalto Co(NO3)2.6H2O, nitrato de ítrio Y(NO3)3.6H2O e como redutor, combustível, foi usado uréia CO(NH2)2 com 300% em excesso. Pós nanométricos de ferritas de cobalto na estrutura de espinélio foram obtidos, formaram agregados cristalinos, com tamanho médio dos cristalitos de 20 ± 3 nm. Os resultados de Difração de raios X mostraram os picos de difração bem definidos característicos da fase de CoFe2O4 pura, não apresentando fase secundária para todas as estequiometrias do composto. Os espectros de infravermelho mostraram as bandas característica das ligações metal e oxigênio nos sítios tetraédricos e octaédricos em torno 590-600 cm-1 e 400 cm-1 respectivamente, bem como deslocamento das mesmas para freqüências maiores, apresentaram também bandas referente a ligações de compostos residuais da etapa de síntese eliminados durante o aquecimento para obtenção dos termogramas. Os termogramas mostraram a estabilidade química do material, a eliminação de compostos residuais e a cristalização do mesmo a partir de 400°C. As micrografias obtidas através da microscopia eletrônica de transmissão mostraram aglomerados cristalinos e através do programa Image J. foi obtido o valor médio dos diâmetros das partículas para a amostra x=1,5% de ~19±6 nm, próximo ao obtido pela equação de Scherrer, que para a referida amostra foi de ~19±3 nm. A microscopia eletrônica de varredura através do Espectrômetro de Energia Dispersiva (EDS) foi usado para determinar a composição química experimental do material e juntamente com o calculado estequiometricamente os valores foram tabelados. Os dados exposto na tabela mostraram uma concordância dos valores calculados com os obtidos. As análises magnéticas revelaram que as amostras apresentam ferrimagnetismo característico da natureza do composto dependente da concentração de Y3+.
294

O estudo do paralelismo no ensino da geometria analítica plana: do empírico ao dedutivo

Hajnal, Fabiana 31 October 2007 (has links)
Made available in DSpace on 2016-04-27T16:58:31Z (GMT). No. of bitstreams: 1 Fabiana Hajnal.pdf: 11059921 bytes, checksum: e7170e4e346abdf66bff5f94b21112d8 (MD5) Previous issue date: 2007-10-31 / Secretaria da Educação do Estado de São Paulo / This dissertation involves a study of argumentation and proof in relation to the teaching and learning of analytic geometry and particularly the property of parallelism in this topic. The work seeks answers to the following questions: in what form can dynamic geometry environments contribute in students attempts to construct mathematical arguments and proof? What difficulties and resistances emerge in learning situations which address the concept of parallelism in analytic geometry? To respond to these questions, sequences of activities, based on some aspects of didactical engineering was designed. For the conception of these activities, the research drew from the work of Parsysz concerning the levels of development of geometrical thinking and the analysis of students´ interactions with the activities was based on the Balacheff´s classification of different types of proof. Analysis of the results obtained in the application of the activity sequence showed that the dynamic geometry environment contributed to the creation of situations that supported the construction of meanings for the concept of parallelism and that the students engaged with the activities in the manner proposed, producing some kind of relevant proof / Esta dissertação tem por objetivo fazer um estudo sobre argumentação e prova envolvendo o paralelismo no ensino da geometria analítica. O trabalho procura responder às seguintes questões: de que forma os ambientes de geometria dinâmica contribuem para que os alunos construam suas argumentações e provas? Quais são as dificuldades ou resistências que se apresentam na situação de aprendizagem do conceito de paralelismo no ensino da geometria analítica? Para responder a esse questionamento, foi concebida uma seqüência de atividades baseada em alguns elementos da engenharia didática. Para a concepção das atividades a pesquisa se apoiou nos trabalhos de Parsysz sobre os níveis do desenvolvimento do pensamento geométrico e para as análises das atividades, na tipologia de provas de Balacheff. A análise dos resultados obtidos na aplicação da seqüência mostrou que o ambiente de geometria dinâmica contribuiu para a criação de situações que ajudaram na construção do conceito de paralelismo e que os alunos alcançaram os objetivos propostos satisfatoriamente e produziram algum tipo de prova
295

Técnicas voltamétricas com eletrodo de filme de bismuto modificado com edta e ebt para determinação de Ca2+ e Mg2+ em biodiesel

MULLER, Renata Medeiros Lobo 19 August 2016 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-07-11T15:58:30Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_TecnicasVoltametricasEletrodo.pdf: 2027355 bytes, checksum: e135aee9ec99391120964ea1e7c406f9 (MD5) / Approved for entry into archive by Irvana Coutinho (irvana@ufpa.br) on 2017-07-18T14:26:49Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_TecnicasVoltametricasEletrodo.pdf: 2027355 bytes, checksum: e135aee9ec99391120964ea1e7c406f9 (MD5) / Made available in DSpace on 2017-07-18T14:26:49Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_TecnicasVoltametricasEletrodo.pdf: 2027355 bytes, checksum: e135aee9ec99391120964ea1e7c406f9 (MD5) Previous issue date: 2016-08-19 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / PETROBRAS - Petróleo Brasileiro S.A. / Este estudo apresenta o desenvolvimento de métodos eletroquímicos alternativos para a determinação de Mg2+ e Ca2+ através da técnica voltametria adsortiva de redissolução (VAdR) com varredura anódica. O eletrodo de filme de bismuto modificado com o Negro de Eriocromo – T (EBT) foi usado para modificação do eletrodo na determinação de Mg2+ no modo diferencial de pulso (DPAdSV), enquanto o EDTA foi usado para a determinação de Ca2+, no modo onda quadrada (SWAdSV). A determinação de Mg2+ foi realizada usando-se tampão acetato (0,1 mol L-1) em pH= 4,5, como eletrólito suporte e EBT 1,0 x 10-3 mol L-1 como ligante. Foram feitas adições sucessivas de alíquotas da solução estoque de Mg2+ 1,0 x 10-3 mol L-1 para que o íon fosse pré-concentrado na superfície do sensor, sob as seguintes condições voltamétricas otimizadas: potencial de deposição (Edep) = -1,0 V; tempo de pré – concentração (tpré) = 120 s; velocidade de varredura (v) = 0,050 V s-1; amplitude de pulso (Amp) = 0,1 V. O complexo formado Mg2+EBT apresentou um pico de corrente em aproximadamente - 0,6 V. A determinação de Ca2+ foi feita utilizando-se tampão amônio (0,01 mol L-1) em pH 9,4, como eletrólito suporte e EDTA 1,0 x 10-2 mol L-1 como ligante, nas seguintes condições otimizadas: potencial de deposição (Edep) = -1,0 V; tempo de pré-concentração (tpré) = 90 s; frequência (Freq.) = 15 Hz; amplitude = 0,075V e Step E) =0,004V. O complexo formado Ca2+EDTA apresentou um pico de corrente em aproximadamente - 0,2 V. Os resultantes foram concordantes, estatisticamente, considerando o teste- t para um nível de confiança de 95%. Os níveis de CV foram menores de 11,0% (Mg2+ e Ca2+), as recuperações ficaram na faixa de 95,0 – 108,0% (Mg2+) e 97,8 – 105,0% (Ca2+) e os valores de limites de detecção foram de 1,05 x 10-6 mol L-1 (Mg2+) e de 2,8 x 10-7 mol L-1 (Ca2+), e de quantificação 3,51 x 10-6 mol L-1 (Mg2+) e 9,46 x 10-7 mol L-1 (Ca2+) para as amostras analisadas, mostrando boa exatidão e sensibilidade do método proposto. Os valores obtidos para as amostras analisadas variaram de 1,47 x 10-5 ± 1,28 x 10-6 mol L-1 (Mg2+) e 5,57 x 10-6 ± 3,77 x 10-7 mol L-1 (Ca2+) nas amostras de biodiesel. A determinação de metais como Ca2+ e Mg2+ por técnicas eletroquímicas com eletrodos quimicamente modificados, tem como principais vantagens sua detectibilidade e a seletividade. / This study presents the development of alternative electrochemical methods for the determination of Mg2+ and Ca2+ through voltammetry technique of adsorptive stripping voltammetry (VAdR) with anodic scan. Bismuth film electrode modified with eriochrome black-T (EBT) was used for modification of the electrode in the determination of Mg2+ in the pulse differential mode (DPAdSV), while EDTA has been used for determination of Ca2+ in wave mode square (SWAdSV). The determination of Mg2+ was performed using acetate buffer (0.1 mol L-1) at pH = 4.5, EBT as supporting electrolyte and 1.0 x 10-3 mol L-1 as a binder. Successive additions of aliquots of the stock solution were made Mg2+ 1.0 x 10-3 mol L-1 so that the ion was pre-concentrated on the sensor surface under the following conditions optimized voltammetric: deposition potential (EDEP) = - 1.0 V; Pre time - concentration (Tpre) = 120 s; scan speed (v) = 0.050 V s-1; pulse amplitude (Amp) = 0.1 V. The complex formed Mg2+ EBT showed a peak current of about - 0.6 V. The determination of Ca2+ was made using ammonium buffer (0.01 mol L-1) at pH 9.4, as supporting electrolyte and EDTA 1.0 x 10-2 mol L-1 as a binder under the following optimum conditions: deposition potential (EDEP) = -1.0 V; preconcentration time (Tpre) = 90 sec; frequency (freq.) = 15 Hz; width = 0,075V and Step E) = 0.004 V. The complex formed Ca2+ EDTA showed a peak current of approximately - 0.2 V. The result was consistent statistically considering t -test for a 95% confidence level. The levels were lower CV of 11.0% (Mg2+ and Ca2+), recoveries were in the range 95.0 to 108.0% (Mg2+) and from 97.8 to 105.0% (Ca2+) and the values of detection limits were 1.05 x 10-6 mol L-1 (Mg2+) and 2.8 x 10-7 mol L-1 (Ca2+), and quantitation 3.51 x 10-6 mol L-1 (Mg2+) and 9.46 x 10-7 mol L-1 (Ca2+) for the samples analyzed, showing good accuracy and sensitivity of the proposed method. The values obtained for the samples ranged from 1.47 x 10-5 ± 1.28 x 10-6 mol L-1 (Mg2+) and 5.57 x 10-6 ± 3.77 x 10-7 mol L-1 (Ca2+) on samples of biodiesel. The determination of metals such as Ca2+ and Mg2+ by electrochemical techniques with chemically modified electrodes has as main advantages its detectability and the selectivity.
296

Desenvolvimento de procedimentos de digestão para óleos lubrificantes. / Development of digestion procedures for lubrificant oils.

Bressani, Flavia Aline 29 April 2005 (has links)
Made available in DSpace on 2016-06-02T20:36:57Z (GMT). No. of bitstreams: 1 DissFAB.pdf: 1058173 bytes, checksum: fe573243ac6da00216ecb5d7c50a0414 (MD5) Previous issue date: 2005-04-29 / Universidade Federal de Minas Gerais / In this work it was developed a digestion procedure for lubricant oil based on gradual addition of sample aliquots on hot and concentrated oxidant acids. The element concentrations in the diluted digestates were determined by inductively coupled plasma optical emission spectrometry with axial viewing (ICP OES). The determination of these metals in lubricant oils is relevant because they can indicate wearing and contamination processes, and presence of additives. The transference of lubricant oil aliquots using either a peristaltic pump or a syringe type pump is not feasible due to the high viscosity of the sample. Thus, two alternative strategies were developed: use of a mechanized system for gradual and controlled addition of oil aliquots to concentrated acids heated by conductive heating and addition of encapsulate oil aliquots to concentrated acids heated by microwave radiation. The resulting digestates presented low residual acidities and carbon contents indicating an efficient digestion process using both procedures. The low acidity of the digestates allows the employ of low dilution factors that improve detection power for ICP OES measurements. Using conductive heating, a mass of 600 mg of oil was digested using 10 mL H2SO4. On the other hand, the microwaveassisted heated acid procedure was effective for digesting this same amount of sample using 3 mL H2SO4 plus 4 mL HNO3. Concentrated hydrogen peroxide was added in the last step in both procedures. In all cases the digestates presented residual carbon contents lower than 2.77% m/m and the residual acidities were around 1 mol/L for 10-fold diluted digestates. Determined and certified values for Ca, Mg, P, and Zn were in agreement at a 95% confidence level. / Neste trabalho desenvolveu-se um procedimento de digestão baseado na adição gradual de amostra ao reagente aquecido para amostras de óleo lubrificante visando análise elementar por espectrometria de emissão óptica com plasma acoplado indutivamente com visão axial (ICP OES). Há um grande interesse na análise elementar pois a variação das concentrações de elementos presentes em óleos lubrificantes pode fornecer informações sobre o desgaste de componentes mecânicos, contaminação e aditivos. Como a alta viscosidade do óleo lubrificante inviabiliza a transferência de alíquotas por bombeamento peristáltico ou utilizando bomba tipo seringa, foram estudadas duas estratégias alternativas para a digestão de óleo lubrificante usando o procedimento de adição da amostra sobre o ácido aquecido: transferência gradual e controlada de alíquotas de óleo lubrificante com o auxílio de um sistema mecanizado sobre o ácido aquecido por aquecimento condutivo e adição do óleo encapsulado ao ácido aquecido por ação de radiação microondas. Os digeridos obtidos foram avaliados segundo a acidez e o teor de carbono residual e apresentaram resultados adequados. Baixos valores de acidez implicam em menores diluições para a análise elementar por ICP OES e maior poder de detecção. Baixos teores de carbono residual (RCC) indicam que a matriz orgânica foi eficientemente destruída. Melhores resultados foram obtidos com aproximadamente 600 mg de óleo adicionado com o sistema mecanizado sobre 10 mL de H2SO4 aquecido em banho de areia e, quando encapsulado, adicionado sobre uma mistura contendo 3 mL de H2SO4 e 4 mL de HNO3. Em ambos os procedimentos, a digestão foi finalizada com a adição de H2O2 concentrado. Resultados para carbono residual foram inferiores a 2,77% m/m e os digeridos introduzidos no ICP OES apresentaram acidez de aproximadamente 1 mol/L para fatores de diluição de 10 vezes. Teores determinados para Ca, Mg, P e Zn foram concordantes com os teores certificados para um nível de confiança de 95%.
297

Desenvolvimento e aplicação de eletrodos compósitos à base de borracha de silicone e grafite.

Oliveira, Aline Carlos de 21 October 2004 (has links)
Made available in DSpace on 2016-06-02T20:36:57Z (GMT). No. of bitstreams: 1 DissACO.pdf: 933043 bytes, checksum: 33e4011be9a9f8332186cded4b603afa (MD5) Previous issue date: 2004-10-21 / Financiadora de Estudos e Projetos / Composite electrodes were prepared using graphite powder and silicone rubber in different compositions. The use of such hydrophobic materials interned to diminish the swallowing observed in other cases when the electrodes are used in aqueous solutions for a long time. The composites were characterized for the response reproducibility, ohmic resistance, thermal behavior and effective area. The voltammetric response in relation to analysts with knows voltammetric behavior was also evaluated, always in comparison with the glassy carbon. Licrean responses were observed for [Fe(CN)6]3- at 50 and 100 mVs-1 scan rates. The electrode 70% (graphite, w/w) was used in the quantitative determination of hydroquinone (HQ) in a DPV procedure in which a detection limit of 5.08x10-8 molL-1 was observed. Hydroquinone was determined in a photographic developer sample with errors lower then 1% in relation to the label value. Dopamine was also determined using a DPV procedure with detection limit of 1.1x10-6molL-1. When pharmaceutical samples containing dopamine were analyzed errors lower then 5% were observed in relation to the label value. / O desenvolvimento de eletrodos compósitos à base de grafite e borracha de silicone (BS) comercial foi investigado. Estes eletrodos apresentam um acentuado caráter hidrofóbico, melhorando suas características em relação à percolação observada em outros materiais poliméricos. Estes compósitos foram caracterizados quanto à reprodutibilidade de superfície eletródica, uma das maiores preocupações devido à consistência macia da borracha de silicone; resistência ôhmica; comportamento térmico e área efetiva, em função da composição grafite/BS. O desempenho eletroquímico dos eletrodos compósitos foi avaliado quanto à sua resposta voltamétrica, respondendo satisfatoriamente a soluções contendo diferentes analitos com comportamento redox conhecido e em relação ao intervalo útil de potenciais, sempre em comparação ao desempenho do carbono vítreo. Curvas analíticas foram obtidas utilizando-se solução de ferricianeto de potássio com velocidade de varredura de 50 e 100mV s-1, apresentando coeficiente de correlação de 0,9997 (n =7), a 50mVs-1 e de 0,9998 (n =6), a 100mV s-1. Para a avaliação da potencialidade analítica dos eletrodos obtidos, foram realizados estudos de quantificação de hidroquinona e dopamina. Os eletrodos foram avaliados em relação à quantificação de hidroquinona, na qual foi obtida uma curva analítica utilizando-se voltametria de pulso diferencial, com limite de detecção de 5,08.10-8mol L-1. A hidroquinona foi determinada em reveladores fotográficos usando o eletrodo compósito grafite/BS 70% (grafite, m/m) e voltametria de pulso diferencial. Os erros relativos obtidos em comparação com o valor rotulado foram inferiores a 1%. Avaliando-se o desempenho dos eletrodos quanto à quantificação de dopamina em voltametria de pulso diferencial, foi obtida uma curva analítica com limite de detecção de 1,10.10-6mol L-1, resultado satisfatório considerando que o analito se adsorve na superfície do eletrodo, sendo necessário renovação da superfície. Ainda com relação à dopamina, foi possível a sua determinação em formulações farmacêuticas, com erros relativos inferiores a 5%.
298

Determinação de As, Sb e Se em material agronômico por espectrometria de emissão óptica acoplada a plasma induzido com geração de hidretos (HG-ICP-OES). / Determination of As, Sb and Se in agronomic samples by hydride generation inductively coupled plasma optical emission spectrometry.

Crispino, Carla Cripa 07 April 2005 (has links)
Made available in DSpace on 2016-06-02T20:36:57Z (GMT). No. of bitstreams: 1 DissCCC.pdf: 1000443 bytes, checksum: ddedf64b615b10f0a375f5b68b3da175 (MD5) Previous issue date: 2005-04-07 / Financiadora de Estudos e Projetos / With the objective to attain maximum productivity with small costs, organic and inorganic chemical parameters are used to evaluate and monitoring crops and animals development. Inorganic amounts in agronomic samples have great importance in the production evaluation. Some of elements in those samples could be an indicative of quality, owing to their requirement (Se) or toxicity (As, Sb), even when they are present in µg kg-1 levels, needing a technique with high sensibility for quantification. The aim of this work was the development of a simple system of hydride generation by continuous flow combined with an inductively coupled plasma optical emission spectrometry for simultaneous determination of As, Sb and Se in agronomic samples. The work attained to a gas-liquid separator development, and an experimental planning to established the chemical and instrumental conditions of hydride generation. The HCl, NaBH4 and KI concentrations, such as the R.F. power, carrier gas flow and the viewing height, were evaluated besides the study of a more appropriate sample preparation. Limits of detection of the proposed system were 0.1 µg L-1 for As, Sb and Se and the limits of quantification were 0.3, 0.2 and 0.2 µg L-1 for As, Sb and Se respectively with RSD smaller than 10% and 30 samples per hour of reading speed. In view to observe the accuracy, four different kinds of samples forage and bovine-derived samples (blood, viscera and semen) were spiking with analytes concentration in the µg L-1 level. Recoveries around 77 to 112% were found. The results present the possibility to use the proposed system in agronomic projects developed with the objective to determine essential and toxic analytes in different kinds of feed and animal samples, contributing to evaluation of nutritional demands and the increase of efficiency in the bovine production systems. / Com o objetivo de atingir a maior produtividade com menores custos, parâmetros químicos, orgânicos e inorgânicos, são usados cada vez mais para avaliar e monitorar o desenvolvimento de uma cultura ou espécie. A determinação de constituintes inorgânicos em amostras agronômicas possui grande importância na avaliação da produção. Alguns elementos presentes nessas amostras são indicativos da qualidade devido à essencialidade (Se) ou toxicidade (As, Sb), porém estão presentes na ordem de µg kg-1, necessitando de uma técnica com alta sensibilidade para quantificação. O objetivo deste trabalho foi o desenvolvimento de um sistema simples de geração de hidretos por fluxo contínuo acoplado a um espectrômetro de emissão óptica com plasma induzido para a determinação simultânea de As, Sb e Se em amostras agronômicas. Esse trabalho envolveu o desenvolvimento de uma câmara de separação gás-líquido e um planejamento experimental para a definição das melhores condições químicas e instrumentais da geração de hidretos. Foram estudadas a concentração de HCl, NaBH4 e KI; a potência de radiofreqüência do plasma, o fluxo do gás carregador e a altura de observação do plasma, além do estudo do preparo de amostra mais adequado. Usando as condições otimizadas, foram obtidos limites de detecção de 0,1 µg L-1 para As, Sb e Se e limites de quantificação de 0,3; 0,2 e 0,2 µg L-1 respectivamente para As, Sb e Se com RSD menores que 10% e velocidade de leitura de 30 amostras por hora. Para observar a exatidão do procedimento proposto quatro amostras diferentes - forrageira e amostras bovinas (sangue, víscera e sêmen) - foram dopadas com os analitos na ordem de µg L-1. Recuperações entre 77 e 112% foram encontradas. Espera-se com essa proposta a complementação dos estudos que determinam analitos essenciais e tóxicos em amostras de tecido, fluídos e na alimentação bovina, contribuindo para a avaliação das exigências nutricionais e o aumento da eficiência dos sistemas de produção de bovinos.
299

Avaliação da viabilidade da determinação de cobalto e cromo em alimentos por espectrometria de absorção atômica com forno tubular na chama e aerossol térmico (TS-FF-AAS). / Evaluation of the feasibility of cobalt and chromium determination in foods by thermospray flame furnance atomic absorption spectrometry (TS-FF-AAS).

Donati, George Luís 23 February 2006 (has links)
Made available in DSpace on 2016-06-02T20:36:58Z (GMT). No. of bitstreams: 1 DissGLD.pdf: 1135923 bytes, checksum: a01e5691bc8173353509b5a00f4b3c7d (MD5) Previous issue date: 2006-02-23 / Universidade Federal de Sao Carlos / In this work, a nickel tube used as atomization cell and a ceramic capillary for thermospray generation (TS-FF-AAS) were employed to increase the analytical performance of the flame atomic absorption spectrometry (FAAS). The applicability of the method was evaluated for Co(II) and Cr(III) determination in food samples. Due to factors such as the low temperature into the atomization tube, the high atomization temperatures of the analytes, and the low levels of these elements in biological samples, a cloud point extraction (CPE) method was applied to both improve the processes of volatilization and atomization by formation of volatile metal complexes, and increase the sensitivity. Triton X-114 was used as surfactant to the implementation of the cloud point preconcentration procedure and, after the evaluation of several complexing agents, the best results were obtained with ammonium pyrrolidinedithiocarbamate (APDC). Parameters such as pH of complexation and concentrations of both surfactant and complexing agent were optimized. To improve the sensitivity, two configurations were evaluated to change the internal temperature of the atomization tube. The slotted tube, in which the internal temperature is higher due to more intense flame penetration, provided a significant increase in Cr(III) sensitivity. Parameters such as flame stoichiometry, atomization tube height, rich phase solvent, sample volume, carrier and flow rate were also evaluated. Limits of detection (LOD) of 2.1 and 2.5 µg L-1 and quantification (LOQ) of 7.0 and 8.4 µg L-1 (n = 10) for Co(II) and Cr(III), respectively, were obtained using optimized conditions. Intermediate precision (5.8 and 5.4 % for Co(II) and Cr(III), respectively), presented as relative standard deviation (RSD, %, 1s), were calculated from 10 consecutive readings of both analytes preconcentrated solutions. Interferences were observed in both volatilization and atomization processes into the atomization tube, as well as in the reactions of metal complexes formation due to both the complexity of the sample and the high concentrations of concomitants. A procedure based on extraction with 1 mol L-1 HCl was adopted for Co(II) determination. Only divalent species are quantitatively extracted. On the other hand, critical interferents, such as Fe(III) and Al(III), are not extracted. Procedures for interferents complexation with either fluorides or ethylenediaminetetraacetic acid (EDTA) were evaluated for Cr(III) determination. Method accuracy was checked by Co(II) determination in two certified reference materials (tomato leaves and bovine liver). There were no statistical differences between determined and certified values in a 95 % confidence level. The proposed method is efficient and allowed the determination of trace concentrations of Co(II) in foods without the need of sample digestion. However, the Cr(III) determination in foods was not possible due to the sample complexity and the interferences caused by concomitants in both preconcentration and determination steps. / Neste trabalho, um tubo de níquel usado como célula de atomização e um capilar cerâmico para a geração de um aerossol térmico (TS-FF-AAS) foram empregados para a melhoria do desempenho analítico da espectrometria de absorção atômica com chama (FAAS). Avaliou-se a aplicabilidade do método para a determinação de Co(II) e Cr(III) em amostras alimentícias. Devido a fatores como a baixa temperatura no interior do tubo atomizador, as altas temperaturas requeridas para atomização e os baixos teores desses elementos em amostras biológicas, foi aplicado um método de extração por ponto nuvem (CPE) visando favorecer os processos de volatilização e atomização pela formação de complexos metálicos voláteis e aumentar a sensibilidade pela pré-concentração dos analitos. Para a implementação do procedimento de pré-concentração por ponto nuvem foi empregado o surfactante Triton X-114 e, na avaliação de diversos complexantes, os melhores resultados foram obtidos para pirrolidinaditiocarbamato de amônio (APDC). Fatores como pH de complexação e concentrações do complexante e do surfactante foram otimizados. Visando ao aumento da sensibilidade, dois tipos de configuração foram avaliados para aumentar a temperatura interna do tubo atomizador. O tubo com maior orifício, cuja temperatura interna é maior devido a uma melhor penetração da chama, apresentou um aumento significativo na sensibilidade para Cr(III). Foram também avaliados parâmetros como estequiometria da chama, altura do tubo atomizador em relação ao queimador, solvente da fase rica, volume de amostra, carregador e vazão. A partir das condições otimizadas foram obtidos limites de detecção (LOD) de 2,1 e 2,5 µg L-1 e limites de quantificação (LOQ) de 7,0 e 8,4 µg L-1 para Co(II) e Cr(III), respectivamente (n = 10). A repetibilidade do método (5,8 e 5,4 % para Co(II) e Cr(III), respectivamente), representada como desvio padrão relativo (RSD, %, 1s), foi calculada a partir de 10 medidas consecutivas de soluções pré-concentradas dos analitos. Foram observadas interferências tanto nos processos de volatilização e atomização no interior do tubo atomizador como na reação de formação dos complexos metálicos devido à complexidade da amostra e às altas concentrações de concomitantes presentes nas amostras analisadas. Na determinação de Co(II), para evitar tais efeitos, foi aplicado um procedimento de extração ácida com solução de HCl 1 mol L-1, no qual apenas espécies divalentes são quantitativamente extraídas enquanto interferentes críticos como Fe(III) e Al(III) não o são. Para Cr(III) foram avaliados procedimentos de complexação dos concomitantes com fluoreto e com ácido etilenodiaminatetraacético (EDTA). A exatidão do método foi verificada pela determinação de Co(II) em dois materiais de referência certificados (folhas de tomateiro e fígado bovino). Não houve diferenças estatísticas entre os teores determinados e certificados em um nível de confiança de 95%. O método é eficiente e possibilitou a determinação de Co(II) em baixas concentrações em amostras comerciais de origem vegetal e animal sem a necessidade de digestão da amostra. Contudo, a determinação de Cr(III) em amostras alimentícias foi impossibilitada devido às altas concentrações e às interferências causadas por concomitantes nas etapas de pré-concentração e determinação.
300

Estudo de procedimentos analíticos para determinação de Cr(III) e Cr(VI) em amostras sólidas. / Evaluation of analytical procedures for determination of Cr(III and Cr(VI) in solid samples.

Matos, Wladiana Oliveira 02 March 2006 (has links)
Made available in DSpace on 2016-06-02T20:36:58Z (GMT). No. of bitstreams: 1 DissWOM.pdf: 867642 bytes, checksum: a5425baf394bc1447e17847d5fd1c4ab (MD5) Previous issue date: 2006-03-02 / Financiadora de Estudos e Projetos / The legislation is evolving towards the establishment of restrictions to the concentration of Cr(VI), the most toxic redox form of chromium, in solid materials. This aspect has stimulated the development of sample preparation procedures for redox speciation analysis of chromium in solid samples. In the work here described it was studied procedures for Cr(VI) extraction in solid samples using alkaline solutions. Molecular absorption spectrophotometry based on 1,5 - diphenylcarbazide as chromogenic reagent was used for the determination of Cr(VI). The quantification of Cr(III) was carried out by the subtraction of the total chromium concentration and the concentration of Cr(VI). The samples employed were: soils, cements, cementrelated materials, nutritional complements and metallic components. The extractor solution composed by 0.10 mol L-1 Na2CO3 presented good performance for solid samples. Tests of stability of Cr(VI) indicated that reduction of Cr(VI) to Cr(III) did not occur in the adopted extraction conditions, even in the presence of significant amounts of Cr(III). The diphenylcarbazide method presents good sensitivity for the determination of Cr(VI) in extracts, however the presence of organic matter in the soil samples caused interferences. The total chromium concentrations were determined using either FAAS or ICP OES after complete decomposition of the samples. Sample preparation procedure for total chromium determination was implemented according to the type of sample. Cement samples and cement-related materials were decomposed by fusion. On the other hand, all the other samples were microwave-assisted digested using high pressure vessels. The main limitation of the studied procedures is the evaluation of accuracy because of the lack of standard reference materials. / A legislação está se desenvolvendo no sentido de estabelecer restrições à concentração de Cr(VI), espécie redox mais tóxica do elemento cromo, em materiais sólidos. Esse aspecto tem estimulado estudos referentes à etapa de preparo de amostra para análise de especiação redox de cromo em amostras sólidas. Neste trabalho avaliou-se procedimento de extração de Cr(VI) em materiais sólidos utilizando soluções alcalinas. A espectrofotometria de absorção molecular utilizando 1,5 - difenilcarbazida como reagente cromogênico foi empregada para a determinação de Cr(VI) nos extratos. A quantificação de Cr(III) foi realizada pela subtração do teor de cromo total e o teor de Cr(VI). As amostras utilizadas no trabalho foram: solos, cimentos, derivados de cimento, multimisturas e peças metálicas. O extrator 0,10 mol L-1 Na2CO3 apresentou boa aplicabilidade para amostras sólidas. Testes de estabilidade de íons Cr(VI) indicaram que reduções de Cr(VI) a Cr(III) não ocorreram nas condições de extração empregadas, mesmo na presença de concentrações significativas de íons Cr(III). O método da difenilcarbazida é sensível e adequado para a determinação de Cr(VI) nos extratos, contudo a presença de matéria orgânica nas amostras de solo causou interferências. As análises de cromo total foram feitas empregando as técnicas de FAAS e ICP OES após completa decomposição das amostras. O método de preparo de amostra utilizado para a determinação de cromo total variou de acordo com o tipo de amostra, sendo que para amostras de cimento e derivados aplicou-se fusão e para as demais amostras adotou-se procedimento de digestão em forno de microondas com cavidade e frascos fechados. A maior limitação dos procedimentos estudados foi a comprovação da exatidão devido à praticamente inexistência de materiais de referência certificados.

Page generated in 0.0804 seconds