• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 96
  • 23
  • 9
  • 4
  • Tagged with
  • 132
  • 84
  • 55
  • 42
  • 40
  • 35
  • 28
  • 20
  • 20
  • 19
  • 19
  • 18
  • 15
  • 15
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Conception d’une tête radiofréquence auto adaptative au milieu de propagation pour les applications médicales

Chan wai po, Francis 23 July 2010 (has links)
L'impédance d'entrée d'une antenne miniature est fortement affectée par des facteurs environnementaux à l'origine de pertes de puissance réduisant l'efficacité énergétique des têtes radiofréquences dans les applications RF, en particulier dans la télémétrie des implants cardiaques. Le but de mes études est de développer une unité de calibration d'impédance d'antenne très faible consommation capable d'adapter toute variation de l'impédance d'entrée de l'antenne à l'impédance de la source radiofréquence. La première partie de mon étude est axée sur la conception au niveau système d'une approche nouvelle de calibration automatique du système. Un réseau d'adaptation automatique d'impédance sans coupleur et fonctionnant de façon directe est étudié et permet d'optimiser la taille du dispositif, la vitesse de l'adaptation, la consommation d'énergie et les performances globales. Deuxièmement, une nouvelle méthode de synthèse du réseau d'adaptation variable est proposée pour réduire fortement la complexité globale de l'algorithme d'adaptation. La troisième partie de mon étude est axée sur la fabrication d'un démonstrateur hybride fonctionnant dans la bande médicale MICS afin de valider le concept auto adaptatif d'impédance. Un banc expérimental qui comprend une antenne immergée dans son milieu connectée au démonstrateur piloté par un microcontrôleur a été mis en place et a permis d'atteindre un coefficient de réflexion jusqu'à -30dB avec un temps de calibration inférieur à 1ms. La dernière partie de mon travail consiste à concevoir le circuit d'adaptation automatique d'impédance d'antenne très faible consommation fonctionnant dans la bande ISM 2.4GHz en utilisant la technologie CMOS 0.13um. / Antenna input impedance is highly affected by environmental factors increasing the losses or reducing the power efficiency of the radiofrequency transceiver in many RF applications such as in implantable pacemaker device telemetry. The purpose of my study is to develop a low power fully integrated antenna-impedance tuning unit to match any variation of the antenna impedance to the source. The first part of my study is focused on the system-level design of a new approach to automatically match the system. A couplerless single step automatic matching network is investigated to optimize the die size, the speed, the power consumption and the overall performance. Second, a new method for synthesizing an automatic matching network is developed reducing strongly the overall complexity of the matching algorithm. The third part of my study is focused on the fabrication of a hybrid demonstrator operating at the Medical Implantable Communication Service (MICS) frequency band to validate the concept. An experimental set-up including the antenna tuning unit, a microcontroller and a pacemaker antenna connected to the demonstrator was done achieving a reflection coefficient up to -30dB, an overall tuning time less than 1ms. The last part of my work is to design the entire automatic matching network circuit in 0.13um CMOS technology including a front-end transceiver designed under ultra low power constraints and operating at 2.4GHz ISM frequency band. The additional items overall power consumption is less than 1.5mW under 1.2V supply voltage.
122

Sources laser non linéaires accordables dans l'infrarouge et l'ultraviolet pour la métrologie des rayonnements optiques / infrared and ultraviolet synchronization of non-linear laser sources aimed at optical radiation metrology

Rihan, Abdallah 19 December 2011 (has links)
L'objet de cette thèse porte sur la conception et la réalisation de deux sources laser non linéaires accordables dans les domaines IR et UV, pour le raccordement de la sensibilité spectrale des détecteurs au moyen du radiomètre cryogénique du laboratoire commun de métrologie (LCM). La source IR est un oscillateur paramétrique optique (OPO) résonant sur les ondes pompe et signal (PRSRO), utilisant un cristal de niobate de lithium à inversion de domaines de polarisation dopé par 5% d'oxyde de magnésium (ppMgCLN). Pompé par un laser Ti:Al2O3 en anneau mono-fréquence et accordable, délivrant 500 mW de puissance utile autour de 795 nm, l'OPO possède un seuil d'oscillation de 110 mW. Une couverture spectrale continue entre 1 µm et 3.5 µm a été obtenue, avec des puissances de l'ordre du mW pour l'onde signal (1 µm à 1.5 µm) et des puissances comprises entre $20$ à $50$ mW pour l'onde complémentaire couvrant un octave de longueur d'onde IR entre 1.7 µm et 3.5 µm. La source UV est obtenue par doublage de fréquence en cavité externe du laser Ti:Al2O3, dans un cristal de triborate de lithium (LiB3O5). Un accord de phase en température à angle d'accord de phase fixé permet l'obtention d'une couverture spectrale comprise entre 390 nm et 405 nm. L'asservissement de la cavité de doublage sur la fréquence du laser Ti:Al2O3 par la méthode de Pound-Drever-Hall, ainsi qu'une adaptation de mode optimale, permet d'obtenir une puissance de 5.64 mW à 400 nm à partir de 480 mW de puissance fondamentale. / The work presented in this PhD dissertation details the strategy adopted to build two non-linear laser sources that are widely in the mid-infrared and blue-UV spectral ranges. These laser sources are needed for the traceability to SI units of coherent light irradiance measurements using a cryogenic radiometer of the using cryogenic radiometer of the Laboratoire commun de métrologie (LCM) .The infrared laser source is an optical parametric oscillator (OPO) resonating on the pump and signal wavelengths (PRSRO) and employing a periodically poled Lithium Niobate non-linear crystal doped with 5% magnesium oxide (ppMgCLN). The PRSRO is pumped by a single-frequency tunable bow-tie ring cavity Titanium-Sapphire laser (Ti:Al2O3) delivering 500 mW output power at 795 nm wavelength, , resulting in a power oscillation threshold of 110 mW. The PRSRO emission could continuously cover the spectral range from 1 µm to 3.5 µm. The level of output power achieved is of the order of 1 mW for the signal wave (1 µm to 1.5 µm) and between 20 mW and 50 mW for idler wave spanning an octave wavelength range (1.7 µm to 3.5 µm).The UV source based on the second harmonic generation on the Titanium-Sapphire tunable laser using an external enhancement cavity containing a critically phase-matched LBO non linear crystal (LiB3O5). Temperature-tuning of the phase-matching condition at a fixed crystal orientation leads to a wide tunability from 390 nm to 405 nm wavelength. The external cavity optical pathlength was actively locked to the laser frequency using a¨Pound-Drever-Hall servo, allowing to extract up to 6 mW power at 400 nm wavelength with a 480 mW pump power. Despite a perfect mode-matching efficiency, the power performance was limited by the poor nonlinear impedance matching of the resonator, due to both the weak nonlinearity of the crystal and the low incoming laser power.
123

Ultrasonic Generator for Surgical Applications and Non-invasive Cancer Treatment by High Intensity Focused Ultrasound / Générateur d'ultrasons pour les applications chirurgicales et le traitement non-invasif du cancer par High Intensity Focused Ultrasound

Wang, Xusheng 11 February 2016 (has links)
La technique de haute intensité ultrasons focalisés (HIFU) est maintenant largement utilisée pour le traitement du cancer, grâce à son avantage non-invasif. Dans un système de HIFU, une matrice de transducteurs à ultrasons est pilotée en phase pour produire un faisceau focalisé d'ultrasons (1M ~ 10 MHz) dans une petite zone de l'emplacement de la cible sur le cancer dans le corps. La plupart des systèmes HIFU sont guidées par imagerie par résonance magnétique (IRM) dans de nos jours. Dans cette étude de doctorat, un amplificateur de puissance de classe D en demi-pont et un système d'accord automatique d'impédance sont proposés. Tous deux circuits proposés sont compatibles avec le système IRM. L'amplificateur de puissance proposé a été réalisé par un circuit imprimé (PCB) avec des composants discrets. Selon les résultats du test, il a rendement de conversion en puissance de 82% pour une puissance de sortie conçue de 1,25W à une fréquence de travail de 3MHz. Le système d'accord automatique d'impédance proposé a été conçu en deux versions: une version en PCB et une version en circuit intégré (IC). Contrairement aux systèmes d'accord automatique proposés dans la littérature, il n'y a pas besoin de l'unité de microcontrôleur (MCU) ou de l'ordinateur dans la conception proposée. D'ailleurs, sans l'aide de composants magnétiques volumineux, ce système d'auto-réglage est entièrement compatible avec l'équipement IRM. La version en PCB a été conçue pour vérifier le principe du système proposé, et il est également utilisé pour guider à la conception du circuit intégré. La réalisation en PCB occupe une surface de 110cm². Les résultats des tests ont confirmé la performance attendue. Le système d'auto-tuning proposé peut parfaitement annuler l'impédance imaginaire du transducteur, et il peut également compenser l'impédance de la dérive causée par les variations inévitables (variation de température, dispersion technique, etc.). La conception du système d'auto-réglage en circuit intégré a été réalisé avec une technologie CMOS (C35B4C3) fournies par Austrian Micro Systems (AMS). La surface occupée par le circuit intégré est seulement de 0,42mm². Le circuit intégré conçu est capable de fonctionner à une large gamme de fréquence tout en conservant une consommation d'énergie très faible (137 mW). D'après les résultats de la simulation, le rendement de puissance de ce circuit peut être amélioré jusqu'à 20% comparant à celui utilisant le réseau d'accord statique. / High intensity focused ultrasound (HIFU) technology is now broadly used for cancer treatment, thanks to its non-invasive property. In a HIFU system, a phased array of ultrasonic transducers is utilized to generate a focused beam of ultrasound (1M~10MHz) into a small area of the cancer target within the body. Most HIFU systems are guided by magnetic resonance imaging (MRI) in nowadays. In this PhD study, a half-bridge class D power amplifier and an automatic impedance tuning system are proposed. Both the class D power amplifier and the auto-tuning system are compatible with MRI system. The proposed power amplifier is implemented by a printed circuit board (PCB) circuit with discrete components. According to the test results, it has a power efficiency of 82% designed for an output power of 3W at 1.25 MHz working frequency. The proposed automatic impedance tuning system has been designed in two versions: a PCB version and an integrated circuit (IC) version. Unlike the typical auto-impedance tuning networks, there is no need of microprogrammed control unit (MCU) or computer in the proposed design. Besides, without using bulky magnetic components, this auto-tuning system is completely compatible with MRI equipment. The PCB version was designed to verify the principle of the proposed automatic impedance tuning system, and it is also used to help the design of the integrated circuit. The PCB realization occupies a surface of 110cm². The test results confirmed the expected performance. The proposed auto-tuning system can perfectly cancel the imaginary impedance of the transducer, and it can also compensate the impedance drifting caused by unavoidable variations (temperature variation, technical dispersion, etc.). The IC design of the auto-tuning system is realized in a CMOS process (C35B4C3) provided by Austrian Micro Systems (AMS). The die area of the integrated circuit is only 0.42mm². This circuit design can provide a wide working frequency range while keeping a very low power consumption (137 mW). According to the simulation results, the power efficiency can be improved can up to 20% by using this auto-tuning circuit compared with that using the static tuning network.
124

Mécanismes de vieillissement de l'Assemblage-Membrane-Électrodes dans une pile à combustible de type PEM par approche expérimentale / Mechanisms of Membrane-Electrode-Assembly aging in PEMFC by experimental approach

Huang, Botao 17 July 2012 (has links)
Cette thèse a permis de mettre en évidence les mécanismes de vieillissement de la pile à combustible de type PEM lors de cyclages d'humidité de l'air et suite à la perforation de l'AME (Assemblage Membrane Electrodes). Premièrement, les mécanismes connus de dégradation des divers composants (membrane, catalyseur, support du catalyseur, GDL, plaques bipolaires et joints d'étanchéité) ont été présentés. Ensuite, les outils de diagnostic en-ligne (chronopotentiométrie, spectroscopie d'impédance, gestion de l'eau et analyse chimique de l'eau) et ceux hors-ligne (CV et LSV) ainsi que des analyses post-mortem (RMN, MET, MEB et DRX) ont été décrits. Expérimentalement, le cyclage en humidité de l'air a été effectué en mono-cellule de 25 cm2: le cyclage à forte humidité entraîne une perte significative de la surface électroactive du catalyseur; le cyclage à faible humidité favorise la perméation de l'hydrogène à travers la membrane. Le cyclage à faible humidité réalisé sur une pile de 100 cm2 a montré un mécanisme de dégradation différent de celui de la pile de 25 cm2: la perméation de l'hydrogène reste faible alors que la tension de la pile était de plus en plus fluctuante certainement du fait de la présence de volumes morts et de la rétention d'eau liquide dans la pile. L'effet de la perforation de l'AME a été étudié sur une pile de 100 cm2: la perforation par une punaise de 0,7 mm de diamètre ne génère qu'une légère augmentation de la perméation de l'hydrogène; la perforation par une punaise de 1,2 mm de diamètre entraîne une chute de tension et l'augmentation significative de la résistance de diffusion de l'oxygène due à la perméation importante de l'hydrogène / This thesis highlights the aging mechanisms of PEM Fuel Cell submitted to two main aging conditions: air relative humidity (RH) cycling, and MEA (Membrane Electrode Assembly) pinhole test of operation. First, the aging mechanisms of PEMFC main components (membrane, catalyst, carbon support, GDL, bipolar plates and gaskets), have been reviewed from the literature. Then the on-line diagnostic tools (chronopotentiometry, electrochemical impedance spectroscopy, water management and water analysis), off-line ones (cyclic voltammetry and linear sweep voltammetry) and post-mortem analyses (nuclear magnetic resonance, transmission electron microscopy, scanning electron microscopy and X-ray diffraction) have been described. Experimentally, the high and low air RH cycling runs have been carried out with a 25 cm2 single cell: the high air RH cycling run promoted serious loss of the ElectroChemical Surface Area (ECSA); the low air RH cycling run caused significant increase in hydrogen crossover. The low air RH cycling has been also performed with a 100 cm2 single cell and the aging mechanism was different from that of 25 cm2 cell: the hydrogen crossover remained very low but the fuel cell voltage exhibited strong fluctuations at the end of the run: this was attributed to the presence of dead volumes and liquid water retention within the cell. Finally, MEA pinhole effect has been investigated with a 100 cm2 single cell: the perforation by a 0.7 mm diameter pin promoted slight increase in the hydrogen crossover; the perforation by a 1.2 mm diameter pin caused significant cell voltage losses and serious increase in the cathode diffusion resistance due to significant hydrogen crossover
125

Contributions à l'amélioration de la performance des conditions aux limites approchées pour des problèmes de couche mince en domaines non réguliers / Contributions to the performance’s improvement of approximate boundary conditions for problems with thin layer in corner domain

Auvray, Alexis 02 July 2018 (has links)
Les problèmes de transmission avec couche mince sont délicats à approcher numériquement, en raison de la nécessité de construire des maillages à l’échelle de la couche mince. Il est courant d’éviter ces difficultés en usant de problèmes avec conditions aux limites approchées — dites d’impédance. Si l’approximation des problèmes de transmission par des problèmes d’impédance s’avère performante dans le cas de domaines réguliers, elle l’est beaucoup moins lorsque ceux-ci comportent des coins ou arêtes. L’objet de cette thèse est de proposer de nouvelles conditions d’impédance, plus performantes, afin de corriger cette perte de performance. Pour cela, les développements asymptotiques des différents problèmes-modèles sont construits et étudiés afin de localiser avec précision l’origine de la perte, en lien avec les profils singuliers associés aux coins et arêtes. De nouvelles conditions d’impédance sont construites, de type Robin multi-échelle ou Venctel. D’abord étudiées en dimension 2, elles sont ensuite généralisées à certaines situations en dimension 3. Des simulations viennent confirmer l’efficience des méthodes théoriques. / Transmission problems with thin layer are delicate to approximate numerically, because of the necessity to build meshes on the scale of the thin layer. It is common to avoid these difficulties by using problems with approximate boundary conditions — also called impedance conditions. Whereas the approximation of transmission problems by impedance problems turns out to be successful in the case of smooth domains, the situation is less satisfactory in the presence of corners and edges. The goal of this thesis is to propose new impedance conditions, more efficient, to correct this lack of performance. For that purpose, the asymptotic expansions of the various models -problems are built and studied to locate exactly the origin of the loss, in connection with the singular profiles associated to corners and edges. New impedance conditions are built, of multi-scale Robin or Venctel types. At first studied in dimension 2, they are then generalized in certain situations in dimension 3. Simulations have been carried out to confirm the efficiency of the theoretical methods to some.
126

Elaboration de matériaux nanostructurés pour piles à combustible SOFC: application à Nd<sub>2</sub>NiO<sub>4+δ</sub> et Ce<sub>1-x</sub>A<sub>x</sub>O<sub>2-y</sub>

Mesguich, David 23 June 2010 (has links) (PDF)
Le développement actuel des piles à combustible SOFC fonctionnant à température intermédiaire suppose l'optimisation des méthodes de synthèse et de mise en forme pour les matériaux nouveaux développés au cours des dernières années. En effet, les propriétés électrochimiques de ces dispositifs sont étroitement liées aux caractéristiques des poudres de départ ainsi qu'à la microstructure des électrodes (ou de l'électrolyte) après leur mise en forme. Une amélioration significative des dites propriétés peut être obtenue par la nanostructuration des matériaux. Dans ce contexte, ce travail de thèse est consacré à l'élaboration du matériau de cathode Nd<sub>2</sub>NiO<sub>4+δ</sub> ainsi que du matériau d'électrolyte Ce<sub>1-x</sub>A<sub>x</sub>O<sub>2-δ</sub>. Les méthodes mises en œuvre sont la synthèse de nanopoudres en milieux éthanol/eau supercritiques et par voie pyrosol ainsi que le dépôt de couches minces en milieu CO2 supercritique. Les objets obtenus ont enfin été caractérisés par spectroscopie d'impédance électrochimique afin de quantifier leur performance pour l'application SOFC.
127

Modélisation du vieillissement et détermination de l'état de santé de batteries lithium-ion pour application véhicule électrique et hybride

EDDAHECH, Akram 12 December 2013 (has links) (PDF)
Cette thèse se concentre sur la fiabilité des batteries lithium pour des applications véhicules à faible émission en CO2. Pour cela, des méthodologies de caractérisation électriques et thermiques, des protocoles et des tests de vieillissement de batteries lithium sous différents modes (cyclage actif, calendaire simple et cyclage/calendaire) ont été mis en œuvre.Une première partie de ces travaux de thèse s'attache à la modélisation et à l'estimation des états de charge et de santé de la batterie.La deuxième partie est consacrée à l'étude du vieillissement calendaire des batteries lithium utilisant la spectroscopie d'impédance comme méthode de caractérisation. Ensuite, une méthode originale pour l'évaluation de l'état santé de la batterie est proposée. Elle est basée sur l'exploitation de l'étape de charge à tension constante lors d'une recharge complète et est donc bien adaptée à une intégration au sein d'un système de gestion de batterie. L'approche introduite est validée sur des données réelles de vieillissement allant jusqu'à deux ans de test.Enfin, une étude du phénomène de régénération de la capacité suite à un vieillissement des batteries de type combiné cyclage/calendaire est menée. Cette dernière partie constitue une ouverture pour le développement de stratégies d'usage des batteries lithium en incluant leur comportement thermique.
128

Système de mesure d'impédance électrique embarqué, application aux batteries Li-ion

Al Nazer, Rouba 24 January 2014 (has links) (PDF)
La mesure d'impédance électrique en embarqué sur véhicule est un sujet clé pour améliorer les fonctions de diagnostic d'un pack batterie. On cherche en particulier à fournir ainsi des mesures supplémentaires à celles du courant pack et des tensions cellules, afin d'enrichir les indicateurs de vieillissement dans un premier temps, et d'état de santé et de charge dans un second temps. Une méthode classique de laboratoire pour obtenir des mesures d'impédance d'une batterie est la spectroscopie d'impédance électrochimique (ou EIS). Elle consiste à envoyer un signal sinusoïdal en courant (ou tension) de fréquence variable balayant une gamme de fréquences d'intérêt et mesurer ensuite la réponse en tension (ou courant) pour chaque fréquence. Une technique d'identification active basée sur l'utilisation des signaux large bande à motifs carrés est proposée. En particulier, des simulations ont permis de comparer les performances d'identification de différents signaux d'excitation fréquemment utilisés dans le domaine de l'identification et de vérifier les conditions correspondant à un comportement linéaire et invariant dans le temps de l'élément électrochimique. L'évaluation de la qualité d'estimation est effectuée en utilisant une grandeur spécifique : la cohérence. Cette grandeur statistique permet de déterminer un intervalle de confiance sur le module et la phase de l'impédance estimée. Elle permet de sélectionner la gamme de fréquence où la batterie respecte les hypothèses imposées par la méthode d'identification large bande. Afin de valider les résultats, une électronique de test a été conçue. Les résultats expérimentaux permettent de mettre en valeur l'intérêt de cette approche par motifs carrés. Un circuit de référence est utilisé afin d'évaluer les performances en métrologie des méthodes. L'étude expérimentale est ensuite poursuivie sur une batterie Li-ion soumise à un courant de polarisation et à différents états de charge. Des essais comparatifs avec l'EIS sont réalisés. Le cahier de charge établi à l'aide d'un simulateur de batterie Li-ion a permis d'évaluer les performances de la technique large bande proposée et de structurer son utilité pour l'estimation des états de vieillissement et de charge.
129

Elaboration et caractérisation de matériaux de type pérovskite, à faible teneur en plomb ou dépourvus de plomb / Elaboration and caracterization of materials type perovskite with low lead content or lead free

Si Ahmed, Fariza 07 March 2017 (has links)
La plupart des matériaux ferroélectriques actuellement utilisés pour les applications industrielles sont des céramiques à base de plomb. De tels composés sont nocifs à l’environnement en raison de la toxicité et de la volatilité de l’oxyde de plomb durant le processus de préparation de ces matériaux. Dans le cadre du respect de l'environnement, la recherche de céramiques sans plomb ou de faible teneur en plomb ayant des propriétés équivalentes est devenue l'une des principales alternatives aux céramiques à base de plomb. C’est dans cette perspective que se situe le présent travail, focalisé sur l’investigation de matériaux de formules : Ba1-xPbx(Ti1-yZry)O3 (2.5% ≤ à x ≤ 10%) et Ba1-xEr2x/3Ti1-yZryO3. La synthèse par voie solide a été utilisée pour l’élaboration des matériaux. Les techniques expérimentales utilisées sont l’analyse thermogravimétrique, la dilatomètrie, la diffraction des rayons X, la microscopie électronique à balayage couplée à un système de microanalyse EDX et la spectrométrie d’impédance. L’utilisation de ces diverses techniques nous a permis d’optimiser les conditions d’élaboration et d’obtenir des céramiques denses de densité supérieures à 90%. Par ailleurs, les paramètres structuraux ont été affinés par la méthode de Rietveld puis discutés. En outre, ces céramiques possèdent des propriétés ferroélectriques classiques et/ou relaxeurs dont certaines ont des caractéristiques diélectriques très intéressantes au voisinage de la température ambiante. De telles compositions dépourvues de plomb ou contenant très peu de plomb permettent de limiter considérablement la pollution de l’environnement. Grâce à leurs bonnes performances diélectriques, ils pourraient être des candidats potentiels pour remplacer les matériaux à base de plomb actuellement usagés dans divers appareillages électroniques. / Most of ferroelectric materials currently used in the industrial applications are lead-based ceramics. Such compounds are harmful to the environment due to the toxicity and volatility of lead oxide during the preparation process of these materials. Therefore, environmental friendly lead-free ceramics or low-lead content materials with equivalent properties has become one of the main topics as an alternative to lead-based ceramics. In this view, the present work focuses on investigating materials with formulas :Ba1-xPbx(Ti1-yZry)O3 (2.5% ≤ x ≤ 10%) and Ba1-xEr2x/3(Ti1-yZry)O3.Solid state route was used for materials elaboration. The experimental techniques used are thermogravimetric analysis, dilatometry, X-ray diffraction, scanning electron microscopy coupled to an EDX microanalysis system and impedance spectrometry. The use of these various processes allowed us to optimize the synthesis conditions and to obtain dense ceramics with density superior to 90%. In addition, the structural parameters were refined by the Rietveld method and then discussed. Furthermore, these ceramics exhibited normal and/or relaxor ferroelectric properties then some of them have very interesting dielectric characteristics in the vicinity of room temperature. Such lead-free ceramics or low-lead content materials reduce significantly the environmental pollution. Due to their good dielectric performances, they could be potential candidates for replacing lead-based materials currently used in various electronic equipments.
130

Étude des propriétés électriques et structurales de verres de sulfures au lithium pour électrolytes de batteries tout-solide / Electrical and structural properties of Li-sulfide glasses as electrolytes for all-solid-state batteries

Cozic, Solenn 15 September 2016 (has links)
Le marché du stockage de l'énergie est en perpétuelle expansion, tant pour les applications nomades que fixes. Afin de répondre aux exigences requises pour les diverses applications (appareils électroniques, véhicules hybrides et électriques, stockage des énergies renouvelables…), des batteries toujours plus performantes, compactes et légères doivent être développées. Pour cela, les batteries utilisant du lithium métallique en tant qu'anode sont les plus attractives en termes de densités d'énergies. Néanmoins, l'utilisation d'électrolytes liquides conventionnels, généralement des solvants organiques inflammables, dans de tels dispositifs soulève des problématiques de sécurité. Les travaux de recherche présentés dans ce manuscrit concernent l'étude de matériaux vitreux pouvant être utilisés en tant qu'électrolyte solide afin de permettre le développement de batteries tout-solide sûres et performantes. Des verres de sulfures au lithium, attractifs pour leurs propriétés de conduction ionique, sont étudiés et caractérisés. Les propriétés de conduction ionique dans les verres étant toujours mal comprises et sujettes à controverses, l'analyse structurale des verres présente ici un réel intérêt pour une meilleure compréhension des corrélations entre structure et propriétés. Un effort de recherche a donc été porté sur l'étude de l'ordre local dans les verres préparés via différentes techniques d'analyse structurale complémentaires. Enfin, les matériaux vitreux, sont de manière générale relativement faciles à mettre en forme. Les verres étudiés dans ce manuscrit peuvent alors également être utilisés en tant qu'électrolytes sous forme de couches minces dans les micro-batteries. Des premiers essais de dépôts par pulvérisation cathodique RF magnétron de couches minces conductrices ont donc été effectués et constituent la première brique à la fabrication de micro-batteries. / The energy storage market is in constant growth for both portable and stationary applications. To satisfy the requirements of various applications (electronic devices, hybrid-electric vehicles, renewable energy storage…), always more efficient, more compact and lightweight batteries have to be developed. Then, thanks to their high energy densities, batteries using Li metal anodes are the most promising to complete this challenge. However, the use of conventional liquid electrolytes raises safety issues, mainly related to the flammability of the organic liquid. In this thesis, glassy materials, exhibiting great interest towards developing solid electrolytes are considered and might enable the development of safe and efficient all-solid-state batteries. Here, Li-sulfide glasses, attractive for their ionic conduction properties, have been studied and characterized. The ionic conduction properties of glasses are still misunderstood and controversial, the structural investigation of glasses is of great interest in order to get a better understanding of structure-properties relationship. Then, the short and intermediate range order of prepared glasses have been investigated by the mean of various complementary structural analysis techniques. Finally, glassy materials are usually quite easy to shape. Thus, studied glasses in this thesis can also be used as thin-film electrolytes in microbatteries. First tests of sputtering of conducting thin-films have been performed by RF magnetron sputtering and constitute a first step in order to design microbatteries.

Page generated in 0.0515 seconds