• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 7
  • 2
  • 2
  • Tagged with
  • 32
  • 20
  • 14
  • 12
  • 10
  • 9
  • 8
  • 8
  • 8
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Spatially resolved studies of the leakage current behavior of oxide thin-films

Martin, Christian Dominik 27 May 2013 (has links)
Im Laufe der Verkleinerungen integrierter Schaltungen ergab sich die Notwendigkeit der alternativen dielektrischen Materialen. Hohe Polarisierbarkeiten in diesen dielektrischen Dünnfilmen treten erst in hoch direktionalen kristallinen Phasen auf. Aufgrund der erschwerten Integrierbarkeit von epitaktischen, einkristallinen Oxidfilmen können nur poly-, beziehungsweise nanokristalle Filme eingesetzt werden. Diese sind jedoch mit hohen Leckströmen behaftet. Weil die Information in einer DRAM-Zelle als Ladung in einem Kondensator gespeichert wird ist der Verlust dieser Ladung durch Leckströme die Ursache für Informationsverluste. Die Frequenz der notwendigen Auffrischungszyklen einer DRAM-Zelle wird direkt durch die Leckströme bestimmt. Voraussetzungen für die Entwicklung neuer dielektrischer Materialien ist das Verständnis der zugrunde liegenden Ladungsträgertransportmechanismen und ein Verständnis der strukturellen Schichteigenschaften, welche zu diesen Leckströmen führen. Conductive atomic force Microscopy ist ein Rastersondenmethode mit der strukturelle Eigenschaften mit lokaler elektrischer Leitfähigkeit korreliert wird. Mit dieser Methode wurde in einer vergleichenden Studie die räumlichen Leckstromverteilungen untersucht. Und es wurde gezeigt, dass es genügt eine nicht geschlossene Zwischenschicht Aluminiumoxid in eine Zirkoniumdioxidschicht zu integrieren um die Leckströme signifikant zu reduzieren während eine ausreichend hohe Kapazität erhalten bleibt. Darüberhinaus wurde ein CAFM modifiziert und benutzt um das Schaltverhalten eines Siliziumnanodrahtschottkybarrierenfeleffektransistor in Abhängigkeit der Spitzenposition zu untersuchen. Es konnte experimentell bestätigt werden das die Schottkybarrieren den Ladungstransport in diesen Bauteilen kontrollieren. Darüber hinaus wurde ein proof-of-concept für eine umprogrammierbaren nichtflüchtigen Speicher, der auf Ladungsakkumulation und der resultierenden Bandverbiegung an den Schottkybarrieren basiert, gezeigt. / In the course of the ongoing downscaling of integrated circuits the need for alternative dielectric materials has arisen. The polarizability of these dielectric thin-films is highest in highly directional crystalline phases. Since epitaxial single crystalline oxide films are very difficult to integrate into the complex DRAM fabrication process, poly- or nanocrystalline thin-films must be used. However these films are prone to very high leakage currents. Since the information is stored as charge on a capacitor in the DRAM cell, the loss of this charge through leakage currents is the origin of information loss. The rate of the necessary refresh cycles is directly determined by these leakage currents. A fundamental understanding of the underlying charge carrier transport mechanisms and an understanding of the structural film properties leading to such leakage currents are essential to the development of new, dielectric thin-film materials. Conductive Atomic Force Microscopy (CAFM) is a scanning probe based technique which correlates structural film properties with local electrical conductivity. This method was used to examine the spatial distribution of leakage currents in a comparative study. I was shown that it is sufficient to include an unclosed interlayer of Aluminium oxide into a Zirconium dioxide film to significantly reduce leakage currents while maintaining a sufficiently high capacitance. Moreover, a CAFM was modified and used to examine the switching behavior of a silicon nanowire Schottky barrier field effect transistors in dependence of the probe position. It was proven experimentally that Schottky barriers control the charge carrier transport in these devices. In addition, a proof of concept for a reprogrammable nonvolatile memory device based on charge accumulation and band bending at the Schottky barriers was shown.
22

Elektrochemische Metallabscheidung mit Kapillarsonden

Müller, Anne-Dorothea 21 February 2002 (has links)
Es wird ein Verfahren zur lokalisierten elektrochemischen Abscheidung metallischer Strukturen aus Kapillarsonden vorgestellt. Der experimentelle Aufbau, die Herstellung der Sonden, das Arbeiten im Nahfeld der Probe (Scherkraft-Abstandsdetektion)sowie die verschiedenen Beschaltungmöglichkeiten der elektrochemischen Zelle werden ausführlich beschrieben. Ergänzend zu den experimentellen Arbeiten werden einerseits numerische Simulationen gezeigt, die zur Veranschaulichung der Potentialverteilung in der Apexregion dienen und qualitativ beschreiben, wie sich das Schichtdickenprofil der abgeschiedenen Strukturen mit den einstellbaren Parametern (Elektrodenpotentiale, Spitze-Probe-Abstand) variieren läßt. Andererseits werden die verschiedenen Beschaltungsmöglichkeiten der Zelle anhand von Schaltungssimulationen verglichen und so die Wahl des günstigsten Arbeitspunktes für die in den Experimenten verwendete (bi)-potentiostatische Abscheidung diskutiert. Mit dieser Anordnung wurden lokalisiert Cluster in einer porösen Aluminiumoxidmembran deponiert und anschließend abgebildet. In weiteren Strukturierungsversuchen wurden Kupfer bzw. Gold lokalisiert elektrochemisch auf ITO abgeschieden, wobei das Schichtwachstum simultan optisch in Transmission beobachtet wurde. Es werden u.a. Strukturen erzeugt, deren laterale Abmessungen kleiner als der Kapillardurchmesser sind (Fokussierung, max. Verhältnis 8:1). Die derzeit kleinsten elektrochemisch erzeugbaren Strukturen haben eine laterale Ausdehnung von ca. 5 Mikrometern. / A method for the localized electrochemical deposition of metal structures using capillary tips is presented. The experimental set-up, the tip preparation, the distance detection in near-field operation (shear-force detection), as well as the different types of circuiting of the electrochemical cell are described in detail. In addition to the experimental work, numerical simulations for the qualitative visualization of the potential distribution around the apex region show, how the films thickness profile can be adjusted with the variable parameters (electrode voltages, tip-sample distance). Circuit simulations of the electrochemical cell allow to pre-estimate the optimum working conditions for the used (bi)-potentiostatic electrode set-up. With this method, clusters have been deposited in a thin film of porous alumin oxide and imaged in shear-force mode. Gold and copper structures have been deposited on ITO, while the film growth was observed optically. The lateral dimension of the deposited structures can be smaller than the inner diameter of the capillaries (maximum focus: 8:1). The smallest structures produced in this work have lateral dimensions of 5 micrometers.
23

Visualisation of Local Charge Densities with Kelvin Probe Force Microscopy

Milde, Peter 19 July 2011 (has links) (PDF)
For the past decades, Kelvin probe force microscopy (KPFM) developed from a sidebranch of atomic force microscopy to a widely used standard technique. It allows to measure electrostatic potentials on any type of sample material with an unprecedented spatial resolution. While the technical aspects of the method are well understood, the interpretation of measured data remains object of intense research. This thesis intends to prove an advanced view on how sample systems which are typical for ultrahigh resolution imaging, such as organic molecular submonolayers on metals, can be quantitavily analysed with the differential charge density model. In the first part a brief introduction into the Kelvin probe experiment and atomic force microscopy is given. A short review of the theoretical background of the technique is presented. Following, the differential charge density model is introduced, which is used to further explain the origin of contrast in Kelvin probe force microscopy. Physical effects, which cause the occurence of local differential charge densities, are reviewed for several sample systems that are of interest in high resolution atomic force microscopy. Experimental evidence for these effects is presented in the second part. Atomic force microscopy was used for in situ studies of a variety of sample systems ranging from pristine metal surfaces over monolayer organic adsorbates on metals to ferroelectric substrates both, with and without organic thin film coverage. As the result from these studies, it is shown that the differential charge density model accurately describes the experimentally observed potential contrasts. This implies an inherent disparity of the measurement results between the different Kelvin probe force microscopy techniques; a point which had been overseen so far in the discussion of experimental data. Especially for the case of laterally strong confined differential charge densities, the results show the opportunity as well as the necessity to explain experimental data with a combination of ab initio calculations of the differential charge density and an electrostatic model of the tip-sample interaction.
24

Elektrochemische Metallabscheidung mit Kapillarsonden

Müller, Anne-Dorothea 09 April 2001 (has links)
Es wird ein Verfahren zur lokalisierten elektrochemischen Abscheidung metallischer Strukturen aus Kapillarsonden vorgestellt. Der experimentelle Aufbau, die Herstellung der Sonden, das Arbeiten im Nahfeld der Probe (Scherkraft-Abstandsdetektion)sowie die verschiedenen Beschaltungmöglichkeiten der elektrochemischen Zelle werden ausführlich beschrieben. Ergänzend zu den experimentellen Arbeiten werden einerseits numerische Simulationen gezeigt, die zur Veranschaulichung der Potentialverteilung in der Apexregion dienen und qualitativ beschreiben, wie sich das Schichtdickenprofil der abgeschiedenen Strukturen mit den einstellbaren Parametern (Elektrodenpotentiale, Spitze-Probe-Abstand) variieren läßt. Andererseits werden die verschiedenen Beschaltungsmöglichkeiten der Zelle anhand von Schaltungssimulationen verglichen und so die Wahl des günstigsten Arbeitspunktes für die in den Experimenten verwendete (bi)-potentiostatische Abscheidung diskutiert. Mit dieser Anordnung wurden lokalisiert Cluster in einer porösen Aluminiumoxidmembran deponiert und anschließend abgebildet. In weiteren Strukturierungsversuchen wurden Kupfer bzw. Gold lokalisiert elektrochemisch auf ITO abgeschieden, wobei das Schichtwachstum simultan optisch in Transmission beobachtet wurde. Es werden u.a. Strukturen erzeugt, deren laterale Abmessungen kleiner als der Kapillardurchmesser sind (Fokussierung, max. Verhältnis 8:1). Die derzeit kleinsten elektrochemisch erzeugbaren Strukturen haben eine laterale Ausdehnung von ca. 5 Mikrometern. / A method for the localized electrochemical deposition of metal structures using capillary tips is presented. The experimental set-up, the tip preparation, the distance detection in near-field operation (shear-force detection), as well as the different types of circuiting of the electrochemical cell are described in detail. In addition to the experimental work, numerical simulations for the qualitative visualization of the potential distribution around the apex region show, how the films thickness profile can be adjusted with the variable parameters (electrode voltages, tip-sample distance). Circuit simulations of the electrochemical cell allow to pre-estimate the optimum working conditions for the used (bi)-potentiostatic electrode set-up. With this method, clusters have been deposited in a thin film of porous alumin oxide and imaged in shear-force mode. Gold and copper structures have been deposited on ITO, while the film growth was observed optically. The lateral dimension of the deposited structures can be smaller than the inner diameter of the capillaries (maximum focus: 8:1). The smallest structures produced in this work have lateral dimensions of 5 micrometers.
25

Etablierung der Rasterkraftmikroskopie an kardiovaskulär relevanten Zellen, Proteinen und Materialien

Richter, Christoph 20 October 2003 (has links)
1981 entwickelten Gerd Binnig und Heinrich Rohrer bei IBM in Zürich das "Scanning Tunneling Microscope". Damit wurde erstmalig das lokal hochaufgelöste Erfassen (bis in den atomaren Auflösungsbereich) von Objekteigenschaften im Nahfeld inerter Oberflächen möglich. Dies und insbesondere die Weiterentwicklung der Technologie und die spätere (1986) Etablierung der Rasterkraftmikroskopie (Atomic Force Microscopy - AFM), die diese Auflösungsmöglichkeiten der Rastersondenmikroskope auch an Non-Konduktoren (nicht leitende Untersuchungsoberflächen) realisieren konnte, stellte die Geburtsstunde einer neuen mikroskopischen Ära auf dem Gebiet der biomedizinischen Grundlagenforschung dar (Kapitel 1.3). Das Studium der umfangreichen Literaturquellen zu diesem Thema und der direkte wissenschaftliche Kontakt und Erfahrungsaustausch mit anderen AFM- Arbeitsgruppen ließen im Initialstadium dieser vorliegenden Arbeit bereits erkennen, dass in der kardiovaskulären Grundlagenforschung zunehmend rasterkraftmikroskopische Versuchsansätze bearbeitet und kardiologisch interessante Fragestellungen mittels dieser Methode begleitend untersucht wurden (Kapitel 1.4). Das Ziel dieser vorliegenden Arbeit bestand darin, kardiovaskulär relevante Zellen und Einzelproteine in vivo und interventionelle Materialien (Stents) rasterkraftmikroskopisch zu untersuchen, wobei die Etablierung und technisch aufwendige Optimierung dieser neuen mikroskopischen (Kapitel 3.1) und der zellspezifisch präparatorischen Methoden (Kapitel 3.2) an diesen Untersuchungsobjekten im Mittelpunkt stehen sollte. Die im Rahmen dieser Arbeit untersuchten endothelialen Zellen und H9C2-Myozyten stammten aus, in unserem Forschungslabor etablierten, immortalen Kulturzelllinien. Die adulten und Kardiomyozyten neonataler Ratten, die kardial- fibrozytären Zellen sowie die Thrombozyten wurden primär isoliert und als Primärkulturzellen kultiviert (Kapitel 3.2.3 und 3.2.4). Außerdem wurden vitale aortale Endothelzellen unterschiedlicher Tiere (Ratte, Meerschwein, Kaninchen) im Gewebsverband der thorakalen Aorta untersucht (Kapitel 4.2). Die Zellen wurden initial, im Rahmen der Etablierungsphase mittels unterschiedlicher Methoden fixiert und nachfolgend rasterkraftmikroskopisch untersucht und dargestellt. Der Etablierungsprozess der Methodik begann mit der Abbildung luftgetrockneter Zellen (Kapitel 4.1.1) unter Raumbedingungen und setzte sich über verschiedene Modifikationen der Zellpräparation (z.B. Glutardialdehydfixation, Cryofixation), des Abbildungsmodus (Contact-, Non-Contact-, Tapping-Mode) und der Abbildungsbedingungen (Raumbedingungen, zellphysiologische Umgebung) fort, so dass schließlich die Abbildung vitaler Zellen (Kapitel 4.1.2 und Kapitel 4.2 - 4.5) in ihrer strukturellen und funktionellen Umgebung (z.B. aortale Endothelzellen im Gewebsverband) etabliert werden konnte und routinemäßig reproduzierbar war. An stabilen oder künstlich stabilisierten Strukturen der o.g. vitalen Zellen wurden erste orientierende Messungen der bioelastischen Eigenschaften (Kraft-Abstands-Kurven, Kapitel 4.1.2.1) durchgeführt. Außerdem haben wir im Einzelfall, wenn technisch und apparativ möglich, andere hochauflösende strukturanalytische Verfahren (z.B. TEM) als mikroskopische Referenzuntersuchungen herangezogen (Kapitel 4.1.2; 4.4.1; 4.6), wobei z.T. erstaunliche Übereinstimmung zwischen den AFM- Daten und den strukturanalytischen Daten der Referenzmethoden nachweisbar waren. Ein strukturell durch Elektronenmikroskopie und Röntgendiffraktionsanalyse sehr gut beschriebenes komplexes Funktionsprotein, das 20-S-Proteasom, wurde mittels der Rasterkraftmikroskopie abgebildet und vermessen und die so gewonnenen strukturanalytischen Daten mit den bekannten strukturellen Abmessungen des Proteins verglichen (Kapitel 4.6). Die hierbei detektierten dimensionalen Abweichungen zwischen den AFM- assoziierten Daten und den bekannten strukturanalytischen Daten der Elektronenmikroskopie wurden im Kontext der funktionellen Integrität des Proteins und hinsichtlich möglicher methodischer Fehlereinflüsse (Kapitel 3.1.4.3) diskutiert. Interventionelle Materialien (Stents), die in der täglichen kardiologischen Praxis Anwendung finden, sind hinsichtlich ihrer Ultrastruktur mittels dieser hochsensitiven Abbildungsmethode im Nahfeld von Objektoberflächen untersucht worden. Bezüglich ihrer nativen Oberflächenbeschaffenheit und ihrer mechanischen Alteration durch den Ballon- Dilatationsprozess wurden die Stents sehr detailliert qualitativ und quantitativ (Kapitel 4.7) beschrieben, wobei Prädilektionsstellen der prozedural- assoziierten mechanischen Beanspruchung der Stents durch die hier beschriebene, oberflächensensitive AFM- Methode sehr genau diskriminiert werden konnten. Die präparierten Stents wurden weiterführend mit humanen Thrombozytenkonzentraten inkubiert und die Zell- Stentoberflächenkontakte sowie mögliche Stentoberflächen- induzierte Veränderungen der Thrombozyten sind morphologisch ausführlich beschrieben worden. Letztendlich wurde im Rahmen der vorliegenden Arbeit die spezifische Aktivierung der vitalen Thrombozyten durch pharmakologische Stimulantien (z.B. ADP) mit der, durch den AFM-Abbildungsprozess induzierten Thrombozytenaktivierung (Kapitel 4.5) unter AFM-Bedingungen verglichen und diskutiert. Die Ergebnisse dieser Arbeit weisen, dass mit der AFM-Technologie und objektorientiert optimierten Mess- und Präparationsmethoden ein neues mikroskopisches Analyseverfahren vorliegt, dass zum einen real-dreidimensionale morphologische Bildgebung bis in den submolekularen Auflösungsbereich an vitalen Zellen und präparierten Proteinkomplexen, zum anderen aber gleichermaßen Funktionsanalytik in Form von Messungen zelldynamischer Prozesse wie Migrationsbewegungen und Kontraktionen sowie visko- elastische Quantifizierung von Zellmembranen erlaubt. Der Vorteil gegenüber den meisten gegenwärtig verfügbaren mikroskopischen Methoden liegt in der neu eröffneten Möglichkeit der seriellen, wiederholten und stabil reproduzierbaren Messung an vitalen Zellen und zellulären Substrukturen. Insofern könnte in Zukunft diese neue Technologie eine methodische Bereicherung der mikroskopisch-morphologisch und funktionell orientierten Analysetechnik darstellen. / In 1981 Binnig and Rohrer invented the "Scanning Tunneling Microscope". Thereby it became feasible to high-resolution record the surface-properties of specimens (up to atomic resolution) at the nearfield of inert surfaces. This and in detail the further development of this technology and the establishment of "Atomic Force Microscopy" (1986), that allows implementation of this resolution capabilities in non-conductors or insulating materials represent the birth of a new microscopic era in the field of biomedical basic research (chapter 1.3). The promise of atomic (scanning) force microscopy (AFM) for cardiovascular research is enormous. The perusal of the extensive literature concerning this topic and scientific contact with other researchers reveals initial the capabilities of this method in cardiovascular basic research. Intriguing questions of cardiology may investigate concomitantly with help of scanning-force-micoscopic approaches (chapter 1.4). The aim of this study was to investigate relevant cardiovascular cells and single proteins in-vivo and specific materials (coronary artery stents) with scanning-force-micoscopic setup. The establishment and expensive optimization of this new microscopic method (chapter 3.1) and of the cell specific preparatory methods (chapter 3.2) represented the center of interest of our inevestigations. The endothelial cells and H9C2-myocytes stem from established imortal cell culture lines. The adult cardiomyocytes and cardiomyocytes of neonatal rats, the fibrocytes and the thrombocytes were primarily cultivated (chapter 3.2.3 and 3.2.4). In addition we investigated aortic endothelial cells of intact aortic tissue of different animals (rat, guinea pig, rabbit - chapter 4.2). During the establish experiments cells underlied different methods of cell-fixation. The primary investigations was performed using air-dried cells (chapter 4.1.1) analyzed in room ambient conditions and were continued by different modifications of cell-preparation. (e.g. glutardialdehyde-fixation, cryo-fixation), of microscopic mode (contact-, non-contact-, tapping-mode) and of cell-specific environmental conditions (from room ambient to cellphysiological medium and temperature). As result we became enabled to investigate (reproducible and routinely) vital cells (chapter 4.1.2 and chapter 4.2 - 4.5) embedded in physiological normal structural und functional ambient conditions (e.g. endothelial cells of intact aortic tisue in-vivo). Additionally, we performed measurements of bio-elastic properties of stable or artificial stabilized structures of named cells (force-distances-curves - chapter 4.1.2.1). If posibble, depending of available technical equipment, we compared our microscopic results with other high-resolution analytical procedures of reference (e.g. TEM - Kapitel 4.1.2; 4.4.1; 4.6) and detected astonishing congruence between the data. Furthermore we analyzed the well-described (electron-microscopy and x-ray-diffraction data) complex 20-S-proteasome using a specific atomic force microscopic setup. Analytical and structural data of these AFM-scans and abovementioned methods were likened (chapter 4.6). The deviations concerning the detected proportions were discussed regarding functional integrity of the protein and with respect to potential methodically determined artifacts. (chapter 3.1.4.3). Assaying (qualitative and quantitative) the surface roughness properties of coronary artery stents, we found significant alterations of stent material induced by balloondilatation. We suppose, that changes in roughness of inner surface of coronary artery stents might induce clinical problems like acute stent-thrombosis and in-stent-restenosis. Finally these stents were coated with human thromboytes to investigate cell-stent-surface interactions. Surface-roughness correllated triggering of thrombocyte adhesion was evaluated by morphological analysis of AFM-scans. Finishing, we have investigated and concluding discussed the specific activation of vital thrombocytes by pharmacological substances (e.g. ADP) and by mechanical stimulation (due to AFM-associated tip-surface-interaction). The results of this work demonstrate, AFM-technology using optimized microscopic setup and object-specific adjusted measurement- and preparation- methods, is an new, powerful, microscopic technique, that allow real-3-dimensional morphological mapping up to submolecular range of resolution in vital cells and protein complexes. Moreover, this technology opens new dimensions in functional analytic of cell migration processes or cellular contractions and in evaluation of visco-elastic quantification of cell membranes. The advantage owed to the most currently available microscopic methods is the option of serial and reproducible measurement of vital cells and subcellular structures. In this respect, this new method might represent a methodical enrichment of the microscopic-morphological and functional oriented analysis-technique in future.
26

Hard X-Ray Scanning Microscope Using Nanofocusing Parabolic Refractive Lenses / Rastersondenmikroskopie mit harter Röntgenstrahlung

Patommel, Jens 08 March 2011 (has links) (PDF)
Hard x rays come along with a variety of extraordinary properties which make them an excellent probe for investigation in science, technology and medicine. Their large attenuation length in matter opens up the possibility to use hard x-rays for non-destructive investigation of the inner structure of specimens. Medical radiography is one important example of exploiting this feature. Since their discovery by W. C. Röntgen in 1895, a large variety of x-ray analytical techniques have been developed and successfully applied, such as x-ray crystallography, reflectometry, fluorescence spectroscopy, x-ray absorption spectroscopy, small angle x-ray scattering, and many more. Each of those methods reveals information about certain physical properties, but usually, these properties are an average over the complete sample region illuminated by the x rays. In order to obtain the spatial distribution of those properties in inhomogeneous samples, scanning microscopy techniques have to be applied, screening the sample with a small x-ray beam. The spatial resolution is limited by the finite size of the beam. The availability of highly brilliant x-ray sources at third generation synchrotron radiation facilities together with the development of enhanced focusing x-ray optics made it possible to generate increasingly small high intense x-ray beams, pushing the spatial resolution down to the sub-100 nm range. During this thesis the prototype of a hard x-ray scanning microscope utilizing microstructured nanofocusing lenses was designed, built, and successfully tested. The nanofocusing x-ray lenses were developed by our research group of the Institute of Structural Physics at the Technische Universität Dresden. The prototype instrument was installed at the ESRF beamline ID 13. A wide range of experiments like fluorescence element mapping, fluorescence tomography, x-ray nano-diffraction, coherent x-ray diffraction imaging, and x-ray ptychography were performed as part of this thesis. The hard x-ray scanning microscope provides a stable x-ray beam with a full width at half maximum size of 50-100 nm near the focal plane. The nanoprobe was also used for characterization of nanofocusing lenses, crucial to further improve them. Based on the experiences with the prototype, an advanced version of a hard x-ray scanning microscope is under development and will be installed at the PETRA III beamline P06 dedicated as a user instrument for scanning microscopy. This document is organized as follows. A short introduction motivating the necessity for building a hard x-ray scanning microscope is followed by a brief review of the fundamentals of hard x-ray physics with an emphasis on free-space propagation and interaction with matter. After a discussion of the requirements on the x-ray source for the nanoprobe, the main features of synchrotron radiation from an undulator source are shown. The properties of the nanobeam generated by refractive x-ray lenses are treated as well as a two-stage focusing scheme for tailoring size, flux and the lateral coherence properties of the x-ray focus. The design and realization of the microscope setup is addressed, and a selection of experiments performed with the prototype version is presented, before this thesis is finished with a conclusion and an outlook on prospective plans for an improved microscope setup to be installed at PETRA III. / Aufgrund ihrer hervorragenden Eigenschaften kommt harte Röntgenstrahlung in vielfältiger Weise in der Wissenschaft, Industrie und Medizin zum Einsatz. Vor allem die Fähigkeit, makroskopische Gegenstände zu durchdringen, eröffnet die Möglichkeit, im Innern ausgedehnter Objekte verborgene Strukturen zum Vorschein zu bringen, ohne den Gegenstand zerstören zu müssen. Eine Vielzahl röntgenanalytischer Verfahren wie zum Beispiel Kristallographie, Reflektometrie, Fluoreszenzspektroskopie, Absorptionsspektroskopie oder Kleinwinkelstreuung sind entwickelt und erfolgreich angewendet worden. Jede dieser Methoden liefert gewisse strukturelle, chemische oder physikalische Eigenschaften der Probe zutage, allerdings gemittelt über den von der Röntgenstrahlung beleuchteten Bereich. Um eine ortsaufgelöste Verteilung der durch die Röntgenanalyse gewonnenen Information zu erhalten, bedarf es eines sogenannten Mikrostrahls, durch den die Probe lokal abgetastet werden kann. Die dadurch erreichbare räumliche Auflösung ist durch die Größe des Mikrostrahls begrenzt. Aufgrund der Verfügbarkeit hinreichend brillanter Röntgenquellen in Form von Undulatoren an Synchrotronstrahlungseinrichtungen und des Vorhandenseins verbesserter Röntgenoptiken ist es in den vergangen Jahren gelungen, immer kleinere intensive Röntgenfokusse zu erzeugen und somit das räumliche Auflösungsvermögen der Röntgenrastermikroskope auf unter 100 nm zu verbessern. Gegenstand dieser Arbeit ist der Prototyp eines Rastersondenmikroskops für harte Röntgenstrahlung unter Verwendung refraktiver nanofokussierender Röntgenlinsen, die von unserer Arbeitsgruppe am Institut für Strukturphysik entwickelt und hergestellt werden. Das Rastersondenmikroskop wurde im Rahmen dieser Promotion in Dresden konzipiert und gebaut sowie am Strahlrohr ID 13 des ESRF installiert und erfolgreich getestet. Das Gerät stellt einen hochintensiven Röntgenfokus der Größe 50-100 nm zur Verfügung, mit dem im Verlaufe dieser Doktorarbeit zahlreiche Experimente wie Fluoreszenztomographie, Röntgennanobeugung, Abbildung mittels kohärenter Röntgenbeugung sowie Röntgenptychographie erfolgreich durchgeführt wurden. Das Rastermikroskop dient unter anderem auch dem Charakterisieren der nanofokussierenden Linsen, wobei die dadurch gewonnenen Erkenntnisse in die Herstellung verbesserten Linsen einfließen. Diese Arbeit ist wie folgt strukturiert. Ein kurzes einleitendes Kapitel dient als Motivation für den Bau eines Rastersondenmikroskops für harte Röntgenstrahlung. Es folgt eine Einführung in die Grundlagen der Röntgenphysik mit Hauptaugenmerk auf die Ausbreitung von Röntgenstrahlung im Raum und die Wechselwirkungsmechanismen von Röntgenstrahlung mit Materie. Anschließend werden die Anforderungen an die Röntgenquelle besprochen und die Vorzüge eines Undulators herausgestellt. Wichtige Eigenschaften eines mittels refraktiver Röntgenlinsen erzeugten Röntgenfokus werden behandelt, und das Konzept einer Vorfokussierung zur gezielten Anpassung der transversalen Kohärenzeigenschaften an die Erfordernisse des Experiments wird besprochen. Das Design und die technische Realisierung des Rastermikroskops werden ebenso dargestellt wie eine Auswahl erfolgreicher Experimente, die am Gerät vollzogen wurden. Die Arbeit endet mit einem Ausblick, der mögliche Weiterentwicklungen in Aussicht stellt, unter anderem den Aufbau eines verbesserten Rastermikroskops am PETRA III-Strahlrohr P06.
27

Visualisation of Local Charge Densities with Kelvin Probe Force Microscopy

Milde, Peter 10 June 2011 (has links)
For the past decades, Kelvin probe force microscopy (KPFM) developed from a sidebranch of atomic force microscopy to a widely used standard technique. It allows to measure electrostatic potentials on any type of sample material with an unprecedented spatial resolution. While the technical aspects of the method are well understood, the interpretation of measured data remains object of intense research. This thesis intends to prove an advanced view on how sample systems which are typical for ultrahigh resolution imaging, such as organic molecular submonolayers on metals, can be quantitavily analysed with the differential charge density model. In the first part a brief introduction into the Kelvin probe experiment and atomic force microscopy is given. A short review of the theoretical background of the technique is presented. Following, the differential charge density model is introduced, which is used to further explain the origin of contrast in Kelvin probe force microscopy. Physical effects, which cause the occurence of local differential charge densities, are reviewed for several sample systems that are of interest in high resolution atomic force microscopy. Experimental evidence for these effects is presented in the second part. Atomic force microscopy was used for in situ studies of a variety of sample systems ranging from pristine metal surfaces over monolayer organic adsorbates on metals to ferroelectric substrates both, with and without organic thin film coverage. As the result from these studies, it is shown that the differential charge density model accurately describes the experimentally observed potential contrasts. This implies an inherent disparity of the measurement results between the different Kelvin probe force microscopy techniques; a point which had been overseen so far in the discussion of experimental data. Especially for the case of laterally strong confined differential charge densities, the results show the opportunity as well as the necessity to explain experimental data with a combination of ab initio calculations of the differential charge density and an electrostatic model of the tip-sample interaction.
28

High-Speed Scanning Tunneling Microscopy on Thin Oxide Film Systems

Gura, Leonard Gordian 13 April 2023 (has links)
Dünne Silizium- und Germaniumdioxidfilme auf Ru(0001)-Kristallen werden hinsichtlich dynamischer Prozesse untersucht. Zwischen Oxidfilm und Substrat befinden sich Sauerstoffatome, die eine ent-scheidende Rolle in diesen Systemen spielen. Zunächst werden diese Sauerstofflagen auf Ru(0001) mittels Hochgeschwindigkeits-Rastertunnelmikroskopie (STM) analysiert. Daraufhin wird die GeO2-Monolage auf Ru(0001) bei hohen Bildraten mit einer selbstentwickelten halbautomatischen Netz-werkdetektion untersucht. Schließlich wird die SiO2-Bilage auf Ru(0001) mit konventionellen sowie mit schnellen STM-Messungen bei Raumtemperatur und bei 600 K abgebildet. Um schnelle Messungen bei hohen Temperaturen zu realisieren, wird ein Hochgeschwindigkeits-STM konstruiert, welches bei unterschiedlichen Temperaturen betrieben werden kann. Unkon-ventionelle Spiralgeometrien ermöglichen verzerrungsfreie Bilder in weniger als 10 ms aufzunehmen. Die adsorbierten Sauerstofflagen werden erstmals bei hohen Bildraten untersucht. Die experimen-tellen Ergebnisse werden durch extern durchgeführte Dichtefunktionaltheorie-Berechnungen ergänzt. In den auf Ru(0001) bei Raumtemperatur stabilen Sauerstofflagen O(2×2), O(2×1) und 3O(2×2) werden dynamische Prozesse beobachtet. Die Besetzung des Zwischenzustandes entlang des Diffusionspfades und schnelle "Umklapp"-Prozesse eindimensionaler Linien werden auf atomarer Ebene aufgelöst. Komplexe Domänengrenzen in der GeO2-Monolage auf Ru(0001) werden mit Hochgeschwindigkeits-STM abgebildet. Die Messungen an der SiO2-Bilage auf Ru(0001) zeigen dynamische Änderungen des Abbildungskontrasts, die mit den mobilen Sauertsoffatomen an der Grenzfläche zusammenhängen können. Messungen bei hohen Temperaturen zeigen dynamische Kontraständerungen von mesoskopischen Strukturen. Diese Messungen stellen die ersten schnellen Hochtemperatur-STM-Aufnahmen des Siliziumdioxidfilms dar und bilden die Grundlage für künftige Studien zu dynamischen Veränderungen in dünnen Oxidschichtsystemen. / Dynamics related to thin silicon- and germanium dioxide films that are grown on Ru(0001) crystals are investigated. Between the film and the metal support oxygen species are present that play a crucial role for these film systems. First, these oxygen adlayers on Ru(0001) are analyzed by high-speed scan-ning tunneling microscopy (STM) with the focus on dynamic processes. In a next step, the monolayer of germanium dioxide (germania) supported on Ru(0001) is studied at elevated frame rates and with a self-designed semi-automated network detection. Finally, the bilayer of silicon dioxide (silica) on Ru(0001) is studied by conventional and by high-speed STM both at room temperature and at 600 K. To realize fast STM measurements at elevated temperatures, a high-speed STM is designed that can operate at variable temperatures. Images are acquired in less than 10 ms with unconventional spiral scan patterns. The dynamics in oxygen adlayers are investigated for the first time at elevated frame rates. Experimental results are supported by density functional theory (DFT) calculations performed externally. Dynamic events are observed in the oxygen adlayers that are stable on Ru(0001) at room temperature, namely O(2×2), O(2×1), and 3O(2×2). The occupation of an intermediate state along the oxygen diffusion pathway and fast "flipping" events of atomic one-dimensional stripe patterns are observed. On the germania monolayer on Ru(0001), complex domain boundary structures are resolved with high-speed STM. In high-speed scans on the silica bilayer on Ru(0001), dynamic changes of the imaging contrast are observed that may relate to the mobile species in the oxygen interfacial layer. Measurements at elevated temperature reveal dynamic contrast changes of mesoscopic features. These measurements constitute the first high-speed STM scans on the silica film at elevated temperatures and form the basis for future studies with the focus on dynamic processes in thin oxide film systems.
29

Characterization of Viral Inhibiting 2D Carbon- Based Structures Using Scanning Probe Microscopy and Raman Spectroscopy

Gholami, Mohammad Fardin 12 June 2024 (has links)
Kohlenstoff 2D-Nanoschichten wie Graphen und Graphenoxid sind vielversprechend, aber schwierig in Bezug auf multivalente Wechselwirkungen zu kontrollieren. Das Verständnis, wie neuartige Funktionalisierungsmethoden die Geometrie, Wechselwirkungen und elektronischen Eigenschaften der Graphenblätter beeinflussen, ist der Schwerpunkt dieser Arbeit. Diese Arbeit untersucht zwei Methoden zur Modifikation von 2D-Graphennanoschichten: "Graft to" und "Graft from" Techniken, unter Verwendung von „[2+1] Nitren-Cycloaddition“ und ringöffnender Polymerisation von Glycerin, zusätzlich zum Wachstum von 2D-Triazin-Kohlenstoffstrukturen. Diese modifizierten Nanoschichten wurden hinsichtlich ihrer Wechselwirkung mit dem Vesikulären Stomatitis-Virus (VSV) und ihrer Zweidimensionalität mittels Rastersondenmikroskopie und Raman-Spektroskopie untersucht. Die Studie zeigt das Potenzial funktionalisierter Graphen in der Virologie und liefert Einblicke für zukünftige Forschungen. Ergebnisse zeigten, dass funktionalisierte 2D-TRGO an VSV-Partikel bindet und flexibel genug bleibt, um auf einer flachen Glimmeroberfläche Falten zu bilden, aber sie können die Virushüllen nicht vollständig umschließen. Dies liegt an den hohen Energiekosten für das Biegen großer lateraler Dimensionen (~1-2 μm) im Vergleich zur 200 nm Länge der VSV-Partikel. Eine optimale laterale Dimension von ~300 nm für funktionalisierte 2D-TRGO-Blätter maximiert virale Wechselwirkungen, Hemmungseffizienz und Anzeichen viraler Umhüllung. Triazin, ein Schlüsselmolekül in der Funktionalisierung, kann zur Herstellung von 2D-Triazin-Strukturen im Gramm-Maßstab verwendet werden. Potenzielle Anwendungen funktionalisierter Graphene umfassen spezialisierte antivirale Therapien und die Verwendung als Plattform für antivirale Medikamente. Zudem zeigten die Ergebnisse minimale Störungen der elektronischen Struktur von Graphen durch Triazin-Funktionalisierung. / Carbon-based 2D nanosheets like graphene and graphene oxide are promising but challenging to control in terms of multivalent interactions. Understanding how novel functionalization methods affect graphene sheets' geometry, interaction specificity and electronic properties is the focus of this thesis, which is crucial for advancing the design of 2D nanomaterials. This thesis examines two novel methods for modifying 2D graphene nanosheets: "graft to" and "graft from" techniques, using [2+1] nitrene cycloaddition reactions and ring-opening multibranch polymerization of glycerol in addition to in plane growth of 2D triazine -carbon based structures. These modified nanosheets were studied for their interaction with vesicular stomatitis virus (VSV) and their two-dimensionality using scanning probe microscopy methods and Raman spectroscopy. The study highlights the potential of functionalized graphene nanosheets in virology and provides insights for future research. Results revealed that functionalized 2D TRGO binds to VSV particles and remains flexible enough to wrinkle on a flat mica interface but they cannot completely wrap the viral envelopes. This is due to the high energy cost of bending large lateral dimensions (~1-2μm) compared to the 200 nm length of VSV particles. An optimum lateral dimension of ~300 nm for functionalized 2D TRGO sheets was found to maximize viral interactions, inhibition efficiency, and signs of viral envelopment. Triazine, a key molecule in functionalization, can also be used to create 2D triazine structures on a gram scale. Functionalized graphene's potential applications include specialized antiviral therapies, such as targeted therapies exploiting multivalent interactions between viruses and cellular receptors, and using functionalized graphene as a delivery platform for antiviral drugs. Additionally, results showed minimal disturbance of graphene electronic structure via Triazine functionalization.
30

Resolving Local Magnetization Structures by Quantitative Magnetic Force Microscopy / Auflösung lokaler Magnetisierungsstrukturen mittels quantitativer Magnetkraftmikroskopie

Vock, Silvia 22 July 2014 (has links) (PDF)
Zur Aufklärung der lokalen Magnetisierungs- und magnetischen Streufeldstruktur in ferromagnetischen und supraleitenden Materialien wurden magnetkraftmikroskopische (Magnetkraftmikroskopie-MFM) Untersuchungen durchgeführt und quantitativ ausgewertet. Für eine solch quantitative Auswertung muss der Einfluß der verwendeten MFM-Spitzen auf das MFM-Bild bestimmt und in geeigneter Weise subtrahiert werden. Hierzu wurden Spitzenkalibrierungsroutinen und ein Verfahren zur Entfaltung der gemessenen MFM-Daten implementiert, das auf der Wiener Dekonvolution basiert. Mit Hilfe dieser Prozedur können sowohl die räumliche Ausdehnung als auch die Größe der Streufelder direkt aus gemessenen MFM-Bildern bestimmt werden. Gezeigt wurde diese Anwendung für die Durchmesserbestimmung von Blasendomänen in einer (Co/Pd)-Multilage und für die Bestimmung der temperaturabhängigen magnetischen Eindringtiefe in einem supraleitendem BaFe2(As0.24P0.76)2 Einkristall. Desweiteren konnte durch die Kombination von mikromagnetischen Rechnungen und der quantitativen MFM-Datenanalyse die Existenz einer dreidimensionalen Vortex-Struktur am Ende von Co48Fe52-Nanodrähten nachgewiesen werden. Damit ist es gelungen die Tiefensensitivität der Magnetkraftmikroskopie erfolgreich in die Rekonstruktion der vermessenen Magnetisierungsstruktur einzubeziehen.

Page generated in 0.098 seconds