• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 246
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 253
  • 177
  • 171
  • 160
  • 98
  • 36
  • 35
  • 34
  • 32
  • 32
  • 31
  • 30
  • 29
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Confiabilidade inter e intraexaminador do diagn?stico de pontos-gatilho miofasciais e limiar de dor ? press?o em m?sculos do ombro

Nascimento, Jos? Diego Sales do 10 October 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-02-21T00:25:24Z No. of bitstreams: 1 JoseDiegoSalesDoNascimento_DISSERT.pdf: 1511173 bytes, checksum: ce7fedccdc99136956a48788dedf00c1 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-03-03T23:11:22Z (GMT) No. of bitstreams: 1 JoseDiegoSalesDoNascimento_DISSERT.pdf: 1511173 bytes, checksum: ce7fedccdc99136956a48788dedf00c1 (MD5) / Made available in DSpace on 2017-03-03T23:11:22Z (GMT). No. of bitstreams: 1 JoseDiegoSalesDoNascimento_DISSERT.pdf: 1511173 bytes, checksum: ce7fedccdc99136956a48788dedf00c1 (MD5) Previous issue date: 2016-10-10 / Objetivo: verificar a confiabilidade inter e intraexaminador do diagn?stico de pontos-gatilho miofasciais (PGMs) e do limiar de dor a press?o (LDP) de m?sculos do ombro, em indiv?duos assintom?ticos e sintom?ticos para s?ndrome do impacto subacromial (SIS) unilateral. Metodologia: Trata-se de um estudo de confiabilidade, composto por 52indiv?duos, 26 assintom?ticos (12 homens e 14 mulheres; 33,8?12,02 anos; IMC de 23,99 kg/m2) e 26 sintom?ticos(12 homens e 14 mulheres; 33,77?11,76 anos; IMC de 24,26 kg/m2) para SIS unilateral. Todos os indiv?duos foram avaliados bilateralmente por dois examinadores inexperientes, independentes e cegos quanto ? condi??o cl?nica do indiv?duo. Os procedimentos consistiram de avalia??o dos m?sculos do ombro quanto ? identifica??o e classifica??o de PGMs em seis m?sculos (trap?zio superior e inferior, infraespinal, supraespinal, peitoral menor e delt?ide m?dio) e LDP em seis m?sculos (trap?zio superior e inferior, infraespinal, supraespinal, delt?ide m?dio e tibial anterior), realizados no mesmo dia. Resultados: A confiabilidade intraexaminador e interexaminador de identifica??o de PGMs foi, de maneira geral, moderada a quase perfeita com porcentagem de concord?ncia (PC) >70%, nos dois grupos, com exce??o de tr?s m?sculos na avalia??o intraexaminador e quatro na interexaminador que apresentaram PC<70%, com confiabilidade entre fraca e razo?vel. Na classifica??o dos PGMs, a confiabilidade do examinador 1 foi fraca a razo?vel em 4 m?sculos, apesar do PC<70% em apenas dois m?sculos, e o examinador 2 obteve PC>70% em todos os m?sculos e confiabilidade entre boa a quase perfeita. J? a confiabilidade interexaminador de classifica??o de PGMs, esta variou entre fraca e moderada, com PC>70% em apenas um m?sculo. Para o LDP, a confiabilidade intraexaminador de ambos os examinadores foi boa ou quase perfeita (ICC: 0.73 ? 0.96) para indiv?duos assintom?ticos e sintom?ticos; a confiabilidade interexaminador foi quase perfeita (ICC: 0.85 ? 0.94) para indiv?duos assintom?ticos e entre boa e quase perfeita em sintom?ticos (ICC: 0.77 ? 0.91). Conclus?o: O estudo evidenciou uma confiabilidade intra e interexaminador aceit?vel na pr?tica cl?nica para identifica??o de PGM, independente dos m?sculos avaliados, mas vari?vel entre condi??es cl?nicas. Quanto ao LDP, a confiabilidade intra e interexaminador apresentou-se adequada para o uso em estudos cl?nicos e pr?tica cl?nica, fornecendo valores de refer?ncia para o LDP. / Objectives: To verify the interrater and intrarater reliability of the diagnosis of myofascial trigger points (MTrPs) and pressure pain threshold (PPT) in the shoulder muscles in asymptomatic individuals and individuals with symptoms of unilateral subacromial impingement syndrome (SIS). Methods: This is a reliability study, composed to 52 individuals, 26 asymptomatic (12 men and 14 women; 33,8?12,02 years old; 23,99 kg/m2 of BMI) and 26 with symptoms of unilateral SIS (12 men and 14 women; 33,77?11,76 years old; 24,26 kg/m2 of BMI). All of the individuals were evaluated by two novice raters, independent and blinded to clinical condition of the individual. The procedures consisted of evaluation the shoulder muscles for identification and classification of MTrPs in six muscles (upper trapezius, lower trapezius, infraspinatus, supraspinatus, pectoralis minor, and middle deltoid) and PPT in also six muscles (upper trapezius, lower trapezius, infraspinatus, supraspinatus, middle deltoid, and tibialis anterior), evaluated in the same day. Results: The intrarater and interrater reliability of identification of MTrPs was, generally, moderated to almost perfect with percentages of agreements (PA) >70%, in both groups, in exception of three muscles in the intrarater reliability and four muscles in the interrater reliability that presented PA<70% and reliability between slight and fair. In the classification of MTrPs, the reliability of rater 1was slight and fair in four muscles, despite the PA>70% only in two muscles; and the rater 2 obtained PA> 70% in all muscles and reliability between good almost perfect. For the interrater reliability of the classification of MTrPs, this was between slight and moderate, with PA>70% in only one muscle. About the PPT, the intrarater reliability of both raters was good or almost perfect (ICC: 0.73 ? 0.96) in asymptomatic and symptomatic individuals, the interrater reliability was almost perfect (ICC: 0.85 ? 0.94) in asymptomatic individuals and between good or almost perfect (ICC: 0.77 ? 0.91) in symptomatic individuals. Conclusion: This studyshowed acceptable intrarater and interrater reliability for clinical practicing to identification of MTrPs, independent of muscles evaluated, but variable between clinical conditions. About the PPT, the intrarater and interrater reliability presented proper to using in clinical studies and practice, providing reference values for PPT.
142

Reprodutibilidade intra e interavaliador na avaliação funcional do quadril

Torresan, Anna January 2017 (has links)
A avaliação da articulação do quadril é considerada desafiadora e medidas reprodutíveis são fundamentais para construir uma prática baseada em evidências. O objetivo da presente dissertação de Mestrado foi avaliar a reprodutibilidade intra e interavaliador do teste de força máxima isométrica com dinamômetro manual, da avaliação fotogramétrica e goniométrica da amplitude de movimento (ADM) e da medida do deslocamento angular do quadril 2-D em vídeo por meio do teste de agachamento unipodal em sujeitos saudáveis. No Capítulo I, por meio de uma ampla revisão de literatura, percebemos a existência de divergências no que diz respeito à avaliação do quadril, uma vez que não foi observada uma avaliação sistematizada envolvendo as medidas mais comumente indicadas na prática clínica. O capítulo II avaliou a reprodutibilidade intra e interavaliador por três avaliadores para os desfechos força muscular por dinamometria manual (rotadores internos (RI) e externos (RE), adutores (ADU) e abdutores (ABD) e flexores (FLX) e extensores (EXT)), ADM do quadril por goniometria (FLX ativa (ATI) e passiva (PAS); RE ATI e PAS e os movimentos de rotação interna bilateral (RI BIL) e EXT ativas e fotogrametria (RE e RI BIL de forma ativa ATI e PAS e deslocamento angular durante o agachamento unipodal para as variáveis flexão de joelho no plano sagital (FLX JOE PS), báscula pélvica (BASC), adução do quadril (ADU QUA) e adução do joelho (ADU JOE) Todas as variáveis foram avaliadas nos lados direito (DIR) e esquerdo (ESQ). Vinte sujeitos do sexo masculino (27,0 ± 4,9 anos; massa corporal: 80,07 ± 13,13 kg; estatura: 1,78 ± 0,06 cm; dominância direita [n=18, 90%]), foram submetidos a dois dias de avaliação da funcionalidade do quadril por três avaliadores: (1) dia 1 pelo avaliador 1; (2) dia 2 por três avaliadores (avaliador 1, 2 e 3, com 30 minutos de intervalo entre as avaliações). A análise dos dados foi realizada no software SPSS v. 20.0, por meio de estatística descritiva (média, DP - desvio padrão) e inferencial (ICC – intraclass correlation coefficient; SEM – Standard error measurement; MDC – minimal detectable change = 1,96*SEM) (α<0,05). O teste t pareado foi utilizado para examinar se houve diferença sistemática entre o teste e re-teste e a ANOVA One-Way para medidas repetidas foi utilizada para comparar as médias entre os avaliadores. Havendo efeito principal significativo, foi utilizado um teste post-hoc de Bonferroni para comparações múltiplas (p≤0,05). Para as medidas de força de todos os grupos musculares, a reprodutibilidade intra-avaliador revelou valores de ICC classificados como excelentes para todos os grupos musculares avaliados (ICC≥0,89; p<0,001) com valores médios de SEM = 11,83 ± 2,94 N e MDC = 23,21 ± 5,80 N A reprodutibilidade interavaliador revelou valores de ICC excelentes para todos os grupos musculares (ICC≥0,90; p<0,001) com valores médios de SEM = 10,69 ± 1,96 N e MDC = 20,93 ± 3,86 N. Em relação às medidas de ADM obtidas por goniometria, a reprodutibilidade intravaliador foi classificada como excelente (ICC≥0,77; p<0,05) com valores médios de SEM = 2,67 ± 0,54°e MDC = 5,21 ± 1,04°, com exceção da ADM de FLX PASS DIR (ICC≥0,68; p=0,100), EXT ATI DIR (ICC=0,73; p=0,030) e ESQ (ICC=0,66; p=0,011), consideradas satisfatórias. A reprodutibilidade interavaliador dos valores de ADM por goniometria foram classificadas como excelentes na comparação interavaliadores (ICC≥0,77; p<0,001) com valores médios de SEM = 5,22 ± 1,04° e MDC = 6,95 ± 6,34°, com exceção dos valores de ICC da variável EXT ESQ ATI considerada satisfatória (ICC=0,62), Quanto à ADM obtidas através da fotogrametria, as medidas apresentaram valores de ICC para reprodutibilidade intra e interavaliador classificados como excelentes (ICC≥0,93 e ≥0,96, respectivamente; p<0,001) e valores médios de SEM = 1,94 ± 0,39°e MDC = 3,8 ± 0,76° (intra-avaliador) e de 1,43 ± 0,18° e 2,80 ± 0,34° (interavaliador), respectivamente Para os valores de deslocamento angular durante o agachamento unipodal, com exceção dos valores de ICC da variável de ADU QUA ESQ (ICC=0,62; p=0,021), classificada como satisfatória, todos os valores de ICC foram considerados excelentes para todas as medidas de reprodutibilidade intra-avaliador (ICC≥0,82; p<0,001), com valores médios de SEM = 2,55 ± 1,01° e MDC = 4,98 ± 1,99°. Para reprodutibilidade interavaliador, todos os valores de ICC foram classificados como excelentes (ICC≥0,87; p<0,001), com valores médios de SEM = 1,78 ± 0,65° e MDC = 3,48 ± 1,26°. Os resultados demonstram que os testes avaliados podem ser usados tanto na prática clínica quanto em pesquisas, pois apresentam medidas confiáveis, uma vez que sua reprodutibilidade intra e interavaliador são satisfatórias/excelentes. Entretanto, aprimoramentos nas técnicas utilizadas são necessários a fim de melhorar a reprodutibilidade e reduzir os erros de medida na avaliação do quadril. / The evaluation of the hip joint continues to be considered challenging and reproducible measures are key to building an evidence-based practice. The objective of this Master's thesis was to evaluate the intra and inter-rater reproducibility of the isometric maximum strength test with manual dynamometer, the photogrammetric and goniometric evaluation of range of motion (ROM) and the 2-D video analysis of single leg squat test in healthy subjects. In Chapter I, through a large literature review, we noticed the existence of disagreements regarding hip assessment, since a systematized evaluation involving the measures most commonly indicated in clinical practice was not observed. Chapter II evaluated the intra and inter-rater reproducibility by three evaluators for manual dynamometry: internal and external rotators (IR and ER), adductors (ADD) and abductors (ABD), flexors (FLX) and extensors (EXT ), hip ROM by goniometry (active extension and bilateral internal rotation; active and passive flexion and external rotation); and by photogrammetry (active and passive IR and ER) and angular displacement during single leg squat (knee flexion in the sagittal plane (KFLX SP), pelvic drop (PD), hip adduction (HADD) and knee adduction (KADD). All variables were evaluated on the right (R) and left (L) sides Twenty male subjects (27.0 ± 4.9 years, body mass: 80.07 ± 13.13 kg, height: 1.78 ± 0.06 cm, right dominance [n = 18, 90%]) were submitted to two days of evaluation of hip functionality by three evaluators: (1) day 1 by the evaluator 1; (2) day 2 by three evaluators (evaluator 1, 2 and 3, with a 30-minute interval between evaluations). Data analysis was performed in SPSS v. 20.0, by means of descriptive statistics (mean, SD - standard deviation) and inferential (ICC - intraclass correlation coefficient; SEM) (α<0.05). The paired t-test was used to examine whether there was a systematic difference between the test and re-test and the One-Way ANOVA for repeated measures was used to compare the means among the evaluators. For the strength measurements of all muscle groups, the intra-rater reproducibility revealed values classified as excellent for all muscle groups evaluated (ICC≥0.89; p<0.001) with SEM values = 11.83 ± 2.94 N and MDC = 23.21 ± 5.80 N. The inter-rater reproducibility revealed excellent ICC values for all muscle groups (ICC≥0.90, p<0.001) with SEM values = 10.69 ± 1.96 N and MDC = 20.93 ± 3.86 N Regarding the measurements of ROM obtained by goniometry, the intra-rater reproducibility was classified as excellent (ICC≥0.77, p<0.05) with mean values of SEM = 2.67 ± 0.54° and MDC = 5.21 ± 1.04°, with the exception of passive right flexion (ICC=0.68; p=0.100), active right extension (ICC=0.73; p=0.030) and active left extension (ICC=0.66; p=0.011), considered satisfactory. The inter-rater reproducibility of ROM values by goniometry were classified as excellent in the inter-rater comparison (ICC≥0.77; p<0.001) with SEM values = 5.22 ± 1.04° and MDC = 6.95 ± 6.34, with the exception of ICC values of the active left extension considered satisfactory (ICC=0.62). Regarding the ROM obtained through photogrammetry, the measurements presented ICC values for intra and inter-rater reproducibility classified as excellent (ICC≥0.93 and ≥0.96, respectively; p<0.001) and mean values of SEM = 1.94 ± 0.39° and MDC = 3.8 ± 0.76° (intra-rater) and 1.43 ± 0.18° and 2.80 ± 0.34° (inter-rater), respectively. For the values of angular displacement during unipodal single leg squat, except for the ICC values of the left hip adduction variable (ICC=0.62; p=0.021), classified as satisfactory, all were considered excellent for all measures (ICC≥0.82, p<0.001), with SEM values = 2.55 ± 1.01° and MDC = 4.98 ± 1.99°. For inter-rater reproducibility, all ICC values were classified as excellent (ICC≥0.87; p<0.001), with SEM values = 1.78 ± 0.65° and MDC = 3.48 ± 1.26°. The results demonstrate that the tests evaluated can be used both in clinical practice and in research, since they present reliable measures, since their intra and inter-rater reproducibility are satisfactory/excellent. However, improvements in the techniques used are necessary to improve reproducibility and reduce measurement errors in hip assessment.
143

Equivalência de mensuração e operacional da versão brasileira do Physical Activity Checklist Interview em crianças / Measurement and operational equivalence of the Brazilian version of the Physical Activity Checklist Interview in children

Fernando Adami 30 June 2011 (has links)
Introdução: Há escassez de questionários que permitam a aferição de atividade física em crianças brasileiras. O Physical Activity Checklist Interview (PACI), desenvolvido em crianças americanas, permite aferir atividade física do dia anterior. Seguindo procedimento de adaptação transcultural, o PACI foi adaptado à cultura brasileira com apreciação das equivalências conceitual, de itens e semântica, resultando na versão em português denominada Lista de Atividades Físicas (LAF). Objetivos: i) identificar questionários para aferição de atividade física em crianças; ii) avaliar as equivalências de mensuração e operacional do LAF. Métodos: Tese composta por três manuscritos. O primeiro apresenta revisão sistemática de questionários de aferição de atividade física para uso em crianças publicados nas bases PubMed, LILACS e SportDiscus no período de 1993 a 2006. O segundo avalia a confiabilidade do LAF utilizando dados de 83 escolares da Escola de Aplicação da USP (EAUSP) com idade entre 7 e 10 anos. Utilizaram-se nas análises os coeficientes de correlação intraclasse (CCI) e de concordância de Lin, e a estratégia de Bland & Altman. O último manuscrito avalia a validade, por meio da correlação entre os dados provenientes do LAF e os de acelerômetros, e a equivalência operacional do LAF, por meio de dados relativos à aplicação do instrumento, e inclui 118 escolares de 7 a 10 anos da EAUSP. Resultados: Manuscrito 1: dezoito questionários que preencheram os critérios de elegibilidade foram descritos segundo suas características, forma de quantificação da atividade física, propriedades psicométricas e aspectos operacionais. Manuscrito 2: pela análise de confiabilidade, observou-se que os índices de atividade física do LAF apresentaram limite inferior do CCI entre 0,84 a 0,96. A precisão e acurácia em relação à concordância perfeita variaram, respectivamente, de 0,83 a 0,97 e de 0,99 a 1. Manuscrito 3: Os valores de correlação entre os resultados provenientes do questionário e do acelerômetro variaram de 0,34 a 0,40. O LAF superestimou o tempo em ativade física moderada a vigorosa quando comparado ao acelerômetro. A duração média da entrevista foi de 24 minutos (desvio padrão = 5 min) e o item da entrevista com pior resultado foi a habilidade em estimar tempo (ruim ou regular em 24,8 por cento das entrevistas). Conclusões: O PACI, identificado a partir de revisão sistemática da literatura, é apresentado de modo adaptado à cultura brasileira seguindo modelo de adaptação transcultural que resultou na Lista de Atividades Físicas - LAF. A utilização do instrumento em estudos epidemiológicos, no entanto, deve ser vista com cautela / Background: There is a lack of questionnaires that allow the assessment of physical activity in Brazilian children. The Physical Activity Checklist Interview (PACI), developed in American children, enables the assessment of physical activity of the previous day. According to the cross-cultural adaptation procedures, the PACI was adapted to Brazilian culture with evaluation of the conceptual, item and semantic equivalence, obtaining the Portuguese version called Lista de Atividades Físicas (LAF). Objectives: i) to identify questionnaires to assess physical activity in children; ii) to assess the measurement and operational equivalence of the Lista de Atividades Físicas. Methods: This thesis consists of three manuscripts. The first presents a systematic review of physical activity questionnaires for use in children published in PubMed, LILACS and SportDiscus from 1993 to 2006. The second assesses the reliability of LAF and includes data from 83 school children aged between 7 and 10 years from Escola de Aplicação da USP (EAUSP). Intraclass correlation coefficient (ICC), Lins concordance correlation coefficient and Bland & Altmans proposal were used in the analysis. The last manuscript assesses the validity of the questionnaire using the correlation between data from LAF and accelerometers, and the operational equivalence of LAF using data concerning the application of the instrument, and includes data from 118 school children aged between 7 and 10 years from EAUSP. Results: Manuscript 1: Eighteen questionnaires met the eligibility criteria and are presented according to their characteristics, physical activity measurement methods, psychometric properties and operational aspects. Manuscript 2: In relation to the reliability analysis, the lower limits of the ICCs varied from 0.84 to 0.96. Precision and agreement varied between 0.83 and 0.97 and between 0.99 and 1, respectively. Manuscript 3: The correlation between the results from the questionnaire and from accelerometer ranged from 0.34 to 0.40. It was found that LAF overestimated the time of moderate to vigorous physical activities when compared to the accelerometer. In terms of operational aspects, mean duration of the interview was 24 minutes (minimum = 13, maximum = 41, standard deviation = 5 min). The interview item showing the poorest result was the ability to estimate the time (poor or fair in 24.8 per cent of the interviews). Conclusion: The PACI, identified from a systematic review, is presented in a way adapted to Brazilian culture following the model of cross-cultural adaptation that resulted in Lista de Atividades Físicas - LAF. However, its use in epidemiological studies must be viewed with caution
144

Avaliação da confiabilidade interexaminador dos testes sensoriais quantitativos em estruturas mastigatórias / Evaluation of interrater reliability of quantitative sensory testing in the masticatory structures

Everardo Napoleão Santana de Araújo Junior 29 March 2018 (has links)
Este estudo estimou a confiabilidade interexaminador e a concordância da avaliação somatossensorial realizada na região do músculo masseter e da articulação temporomandibular (ATM) em um grupo de voluntários saudáveis do sexo feminino e masculino. Quarenta participantes saudáveis (20 homens e 20 mulheres) foram avaliados em duas sessões por dois examinadores diferentes. Os testes aplicados foram limiar de detecção ao frio (CDT, siglas em inglês), limiar de detecção ao calor (WDT), limiar sensorial térmico (TSL), limiar de dor ao frio (CPT), limiar de dor ao calor (HPT), limiar de detecção mecânica (MDT), limiar de dor mecânica (MPT) Razão da somação temporal (WUR) e o limiar de dor a pressão (PPT). ANOVA, coeficiente de correlação intraclasse (ICC) e erro padrão de mensuração (SEM) foram computados ( = 5%). O intervalo de confiança de 95% sem sobreposição (IC 95%) dos valores de ICC foi considerado significativamente diferente. Setenta e sete por cento dos valores de ICC de todas as medidas do QST variaram entre razoável a excelente (ICCs: 0,47-0,97). No entanto, a confiabilidade do WDT, TSL e HPT do masseter foi significativamente maior do que da ATM, enquanto que a confiabilidade de MDT da ATM foi maior do que do músculo masseter. Além disso, a seguinte combinação de teste/sítio apresentou os menores valores de ICC nas mulheres: HPT e MDT da ATM e MPT de ambos os sítios ATM e masseter. Para o erro padrão de mensuração, os maiores valores foram apresentados no CPT e MPT. A avaliação somatossensorial geral das estruturas de mastigatórias realizadas por dois examinadores pode ser considerada suficientemente confiável para discriminar os participantes. No entanto, as possíveis influências do sitio e do sexo nos parâmetros de reprodutibilidade devem ser levadas em consideração para uma interpretação e aplicação clínica apropriadas. / This study estimated the interrater reliability and agreement of the somatosensory assessment performed at masseter and temporomandibular joint (TMJ) region in a group of healthy female and male participants. Forty healthy participants (20 men and 20 men) were evaluated in two sessions by two different examiners. Cold detection threshold (CDT), warm detection threshold (WDT), thermal sensory limen (TSL), cold pain threshold (CPT), heat pain threshold (HPT), mechanical detection threshold (MDT), mechanical pain threshold (MPT), wind-up ratio (WUR) and pressure pain threshold (PPT) were assessed on the skin overlying masseter body and TMJ. Mixed ANOVA, Intraclass Correlation Coefficients (ICC) and standard error of measurement (SEM) were applied to the data (=5%). Non-overlapping 95% confidence intervals (95% CI) of ICC values were considered significantly different. The ICC values of 77% of all QST measurements were considered fair to excellent (ICCs: 0.47-0.97). However, the reliability of WDT, TSL and HPT of masseter was significantly higher than TMJ, whereas the MDT reliability of TMJ was higher than masseter. In addition, the following combination of test/sites presented significantly lower ICCs for women: HPT, MDT of TMJ and MPT of both TMJ and masseter. Finally, the highest SEM values were presented for CPT and MPT. The overall somatosensory assessment of the masticatory structures performed by two examiners can be considered sufficiently reliable to discriminate participants. Nevertheless, possible site and sex influences on the reproducibility parameters should be take into account for an appropriate interpretation and clinical application.
145

Avaliação da reprodutibilidade dos parâmetros de adequação da hemodiálise crônica / Evaluation of reproducibility of adequacy Parameters in chronic hemodialysis

Manente, Marislei January 2002 (has links)
Justificativa: Doses inadequadas de diálise estão associadas a maior morbidade e mortalidade em pacientes com uremia terminal em tratamento hemodialítico. Atualmente os métodos mais utilizados para medir a adequação da hemodiálise baseiam-se no cálculo da depuração fracional de uréia (Kt/V) e da taxa de redução da uréia (URR). Nesse estudo avaliou-se a reprodutibilidade do Kt/V e da URR e analisou-se o número aceitável de medidas mensais destes parâmetros para determinar de forma fidedigna a adequação da hemodiálise. Métodos: Avaliamos 43 pacientes clinicamente estáveis, em cinco sessões de hemodiálise (sessões 1 a 5), durante três semanas. Três diálises consecutivas na primeira semana (sessões 1, 2, 3) e duas sessões de meio de semana, nas duas semanas subseqüentes (sessões 4 e 5). Resultados: Não houve diferença entre a média dos Kt/Vs obtidos em diálises seqüenciais (1, 2 e 3) comparada a média dos Kt/Vs obtidos em diálises no meio da semana (2, 4 e 5). O mesmo aconteceu com a URR e com os coeficientes de variação do Kt/V e da URR. Também não encontramos diferença entre uma medida mensal (Kt/V 2) e três medidas mensais (média dos Kt/Vs 2, 4 e 5). O mesmo ocorreu com a URR. A diferença entre o Kt/V 2 e a média dos Kt/Vs 2, 4 e 5 foi de – 0,02 unidades e entre a URR 2 em relação a média das URRs 2, 4 e 5 foi de – 0,5%. Além disso, se fizermos apenas uma medida mensal (Kt/V 2) 80% dos pacientes estarão a uma distância de no máximo 0,16 unidades abaixo da média dos Kt/Vs 2, 4 e 5 e no máximo 0,12 unidades acima. Em relação a URR 80% dos pacientes estarão a uma distância de no máximo 4,37% abaixo da média das URRs 2, 4 e 5 e no máximo 3,37% acima. O grau de concordância entre o Kt/V 2 e a média dos Kt/Vs 2, 4 e 5 é bom para pontos de corte do Kt/V igual ou superior a 1,3. No caso da URR a concordância é boa para pontos de corte acima de 65%. Conclusão: Concluímos que nesta população de pacientes clinicamente estáveis os parâmetros de adequação da hemodiálise mostraram-se reprodutíveis não havendo necessidade de aumentar o número de medidas mensais da quantidade de diálise ofertada. / Background: Inadequate doses of dialysis are associated with higher morbidity and mortality rates for end-stage renal disease (ESRD) patients undergoing hemodialysis treatment. Most methods aimed at measuring dialysis adequacy use the calculation of fractional clearance of urea (Kt/V) and urea reduction ratio (URR). This study evaluates the reproducibility of Kt/V and URR and analyzes the acceptable number of monthly measurements of these parameters to determine hemodialysis adequacy. Methods: We evaluated 43 clinically stable patients in five hemodialysis sessions (1 to 5) along three weeks. Three consecutive sessions were carried out in the first week (1, 2, 3), while the two other studied sessions were carried out in the middle of the week at weekly intervals (4, 5). Results: There was no difference between mean Kt/V in sessions 1, 2, and 3 and in sessions 2, 4, and 5. The same was observed for URR and the coefficients of variation for Kt/V and URR. Either differences were found between one monthly measurement (2) or three monthly measurements (mean of 2, 4, and 5) for Kt/V and URR. The difference between Kt/V 2 and the arithmetic mean of Kt/Vs 2, 4, and 5 was – 0.02 units, and between URR 2 and the mean of URRs 2, 4, and 5 was – 0.5%. When only one monthly measurement (Kt/V 2) was considered, 80% of the patients presented ≤0.16 unit below or ≤0.12 above the mean of Kt/Vs 2, 4, and 5. For URR, 80% of patients presented ≤4.73% below or ≤3.37% above the arithmetic mean of URRs 2, 4, and 5. The degree of agreement between Kt/V 2 and the mean of Kt/Vs 2, 4 and 5 is good for Kt/Vs of 1.3 or higher. URR agreements are good for URR of 65% or higher. Conclusion: In this population, hemodialysis adequacy parameters were reproducible, and an increase in the number of monthly measurements seems not to be necessary.
146

Avaliação da qualidade de vida em cardiopatia isquêmica : validação de instrumentos para uma população brasileira

Franzen, Elenara January 2005 (has links)
Objetivos: validar versões em português do Short Form Health Survey (SF-36) e do Seattle Angina Questionnaire (SAQ) para avaliação de qualidade de vida em pacientes brasileiros com cardiopatia isquêmica. Métodos: estudo transversal com instrumentos traduzidos e aplicados em dois grupos: em 200 pacientes ambulatoriais com cardiopatia isquêmica estável em dois momentos, com intervalo de 14 dias; e em 50 pacientes antes e 30 dias após a angioplastia. Classe funcional foi avaliada pelo Specific Activity Scale. Testes de correlação intraclasse, Cronbach α e Wilcoxon foram utilizados. Resultados: os participantes dos dois grupos apresentaram características clínicodemográficas semelhantes, sendo a taxa de resposta de 78% e 76% no reteste. Reprodutibilidade dos instrumentos (coeficiente α de Cronbach) variou de 0,70 a 0,90 e 0,62 a 0,79 para os domínios do SF-36 e do SAQ, respectivamente. Estabilidade dos instrumentos em 14 dias (coeficiente de correlação intraclasse) foi >0,68 e >0,49 para os domínios do SF-36 e SAQ. No quesito responsividade, o SF-36 demonstrou melhora nos domínios capacidade funcional (10,5), dor (16,5), vitalidade (13,5), aspecto social (10,1) e saúde mental (9,8); e no SAQ, nos domínios estabilidade (41,1) e freqüência (27,3) da angina e percepção da doença (12,0). Os domínios do SF-36 e do SAQ, exceto um, foram consistentemente relacionados à classe funcional. Conclusão: as versões traduzidas dos instrumentos mostraram desempenho adequado sem diferenças entre si, sugerindo serem reprodutíveis, responsivas e válidas para a avaliação da qualidade de vida em pacientes com cardiopatia isquêmica no Brasil. / Objectives: To validate Portuguese-language versions of the Short Form Health Survey (SF-36) and of the Seattle Angina Questionnaire (SAQ), for the evaluation of quality of life in Brazilian patients with ischemic heart disease. Methods: Cross-sectional study using instruments translated and applied to two groups: 200 outpatients with stable ischemic cardiomyopathy at two points in time- 14-day interval; and 50 patients pre and 30 days post angioplasty. Functional class was evaluated by the Specific Activity Scale. Intra-class correlation, Cronbach’s alpha and Wilcoxon tests were used. Results: The participants in both groups presented similar clinical-demographic characteristics, and the rate of response in the retest was 78% and 76%. Reproducibility of the instruments (Cronbach alpha coefficient) varied from 0.70 to 0.90 and 0.62 to 0.79 for the SF-36 and SAQ domains, respectively. Stability of instruments in 14 days (intraclass correlation coefficient) was ≥0.68 and ≥0.49 for the SF-36 and SAQ domains. For the responsiveness item, SF-36 showed improvement in the domains physical functioning (10.5), bodily pain (16.5), vitality (13.5), social functioning (10.1) and mental health (9.8); and in SAQ in those concerning stability (41.1) and frequency (27.3) of angina and disease perception (12.0). The SF-36 and SAQ domains except one were consistently related to functional class. Conclusion: The translated versions of the instruments showed an adequate performance without differences amongst them, suggesting that they are reproducible, responsive and valid to evaluate quality of life in ischemic heart disease patients in Brazil.
147

Reprodutibilidade do teste de sobrecarga hidrica realizado em diferentes horarios do dia / Reproductility of the water drinking test performde at different times of the day

Medina, Flavio Mac Cord, 1978- 01 December 2009 (has links)
Orientadores: Jose Paulo Cabral de Vasconcellos, Vital Paulino Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-12T19:09:11Z (GMT). No. of bitstreams: 1 Medina_FlavioMacCord_M.pdf: 2280525 bytes, checksum: d64f96bf19c317e1e22a704a8562d282 (MD5) Previous issue date: 2009 / Resumo: Objetivo: Avaliar a reprodutibilidade do teste de sobrecarga hídrica (TSH) em diferentes horários em que é realizado, em pacientes com glaucoma primário de ângulo aberto (GPAA) e em indivíduos normais. Métodos: Quinze pacientes com GPAA e 30 indivíduos normais foram submetidos a três TSHs, realizados em diferentes horários do dia (às 7:00, 12:00 e 17:00), em três dias diferentes. Foram comparados os resultados dos testes em pacientes com GPAA e indivíduos normais. Foram analisadas a concordância e a correlação entre os valores de medida basal, pico e variação de pressão intra-ocular (PIO) (pico de PIO - PIO basal) nos testes realizados nos diferentes horários. Apenas as medidas do olho direito foram analisadas. Resultados: Os valores médios de medida basal, pico e variação de PIO foram significativamente maiores nos pacientes glaucomatosos que nos indivíduos normais, em todos os horários (p<0,05). A análise de Bland-Altman apresentou limites de concordância de pico e variação de PIO maiores do que o clinicamente aceitável (> 3 mmHg), apesar de o teste de Pearson demonstrar boa correlação entre os resultados. Conclusões: O TSH apresenta valores de pico e variação de Pio significativamente maiores em pacientes glaucomatosos que em indivíduos normais. Os baixos níveis de concordância entre os TSHs realizados em diferentes horários do dia sugerem uma baixa reprodutibilidade do TSH, que pode limitar sua aplicabilidade para diagnóstico e acompanhamento do glaucoma / Abstract: Purpose: To evaluate the reproducibility of the water drinking test (WDT) performed at different times of the day, in primary open angle glaucoma (POAG) patients and normal individuals. Methods: Fifteen patients with POAG and 30 normal individuals underwent three WDTs at different times of the day (7 AM, 12 PM, and 5 PM) on 3 different days. Test results in POAG patients and normal individuals were compared. Agreement and correlation of intraocular pressure (IOP) baseline levels, peak levels, and IOP change (peak IOP - baseline IOP) on tests performed at different times were evaluated. Only right eye measurements were analyzed. Results: Mean baseline IOP, peak IOP and IOP change were significantly higher in POAG patients than in normal individuals, at all time intervals (p<0.05). The Bland-Altman analysis demonstrated limits of agreement for IOP peak levels and IOP changes larger than the clinically acceptable (> 3 mmHg), even though Pearson's test revealed good correlation among the results. Conclusions: The mean IOP peak and mean IOP change observed during the WDT are significantly higher in POAG patients than in control individuals. Low levels of agreement among WDTs performed at different times of the day suggest a poor reproducibility of WDT, which may limit its applicability for the diagnosis and follow-up of glaucoma / Mestrado / Oftalmologia / Mestre em Ciências Médicas
148

Desenvolvimento e validação de um instrumento para avaliar espiritualidade: Escala de Atitudes Relacionadas à Espiritualidade (ARES) / Development and validation of an instrument to evaluate spirituality: Spirituality-Related Attitude Scale (ARES)

Camilla Casaletti Braghetta 08 August 2017 (has links)
Objetivos: Desenvolver um novo instrumento para avaliar espiritualidade e realizar análises psicométricas de validade e confiabilidade. Métodos: O instrumento foi elaborado através de quatro etapas: fundamentação teórica, investigação sobre definições de espiritualidade na população geral, elaboração da primeira versão por um comitê de especialistas e teste de compreensibilidade. Nas análises psicométricas, o instrumento foi submetido à avaliação de juízes e posteriormente, foi testado em estudantes de medicina (N=85) e em uma população de religiosos (N=85), para cálculo de consistência interna, análise fatorial exploratória e confiabilidade teste-reteste. Resultados: O instrumento desenvolvido, a Escala de Atitudes Relacionadas à Espiritualidade (ARES), apóia-se na compreensão sobre espiritualidade no contexto brasileiro e em bases teóricas. Apresentou análises psicométricas apropriadas: a análise fatorial exploratória apontou uma estrututura unidimensional, o alfa de Cronbach encontrado em cada item foi >= 0,98 e o Coeficiente de Correlação Intraclasse (CCI=0,98) apontou boa reprodutibilidade da escala. Conclusão: ARES é um instrumento unidimensional, desenvolvido em idioma português, que apresentou consistência interna excelente e indicou ser reprodutível na população avaliada. São necessários mais estudos para verificar se ARES é aplicável em amostra com baixa escolaridade e em outros contextos culturais e religiosos. A escala ARES permite operacionalizar o construto espiritualidade em pesquisas quantitativas / Objectives: Develop a new instrument devised to measure spirituality, able to perform psychometric analysis of validity and reliability. Methods: The instrument was elaborated through four processes: theoretical foundation, a population based investigation about possible definitions of spirituality, a first version was achieved by a committee of experts in Spirituality along with a comprehension test. In psychometric analysis, the analysis was evaluated by judges, then tested in a population of medical students (N = 85) and in a religious population (N = 85), in order to calculate internal consistency, exploratory factor analysis (EFA) and reliability, through test-retest. Results: The instrument, ARES, a Spirituality-Related Attitudes Scale, was based on theoretical understandings of spirituality in the Brazilian context. It presented an appropriate psychometric analysis: the EFA indicated a one-dimensional structure, the Cronbach\'s Alpha found each item at >= 0.98 and the Intraclass Correlation Coefficient (ICC = 0.98) indicated good reproducibility of the scale. Conclusion: ARES is a one-dimensional instrument, developed in the Portuguese language, which presented an excellent internal consistency and indicated to be reproducible in the evaluated population. Further studies are needed to verify if ARES is applicable to other population samples, for example, a low SES and other cultural/religious contexts. The ARES scale allows for operationalization of the construct of spirituality in quantitative researches
149

Avaliação da confiabilidade e validade da versão em português (SCI-MOODS - VP) de uma entrevista estruturada para o espectro do humor, a Structured Clinical Interview for Mood Spectrum (SCI-MOODS) / Reliability and Validity of a Brazilian Portuguese mood spectrum interview (SCI-MOODS-VP), the Structured Clinical Interview for Mood Spectrum (SCI-MOODS)

Roberto Ratzke 11 April 2007 (has links)
A SCI-MOODS (Entrevista Clínica Estruturada para o Espectro do Humor) é uma entrevista de 161 itens com sete subdomínios (humor depressivo e maníaco, energia depressiva e maníaca, cognição depressiva e maníaca e ritmicidade) que avalia o humor de forma dimensional, permitindo um diagnóstico mais preciso de transtornos afetivos. O objetivo deste estudo é desenvolver uma versão em português, a SCI-MOODS -VP, determinando sua confiabilidade, validade e uma linha de corte entre pacientes bipolares e unipolares e portadores de transtornos do humor e controles (normais e esquizofrênicos). A SCI-MOODS, versão 3.0, foi traduzida do inglês para o português brasileiro e posteriormente retro-traduzida. Foram selecionados, bipolares (n=47), unipolares (n=47), esquizofrênicos (n=18), e sujeitos sem transtorno psiquiátrico (n=22), de acordo com o SCID-I/P. Uma análise discriminante progressiva passo a passo foi feita entre os subdomínios de bipolares e unipolares além de uma curva ROC para determinar o melhor ponto de corte. A consistência interna de domínios e subdomínios da SCI-MOODS-VP variou entre 0.86 to 0.94. A confiabilidade entre examinadores de uma amostra de 10 bipolares e 10 unipolares apresentou coeficiente de correlação intra-classe de 0,956. Os sujeitos bipolares apresentaram escores total e maníaco da SCI-MOODS - VP maiores que os outros grupos. A curva receiver operating characteristic (ROC) do escore maníaco entre bipolares e unipolares apresentou área abaixo da curva (AUC) de 0,909. O escore maníaco igual ou acima de 30 demonstrou sensibilidade de 91, 49% e especificidade de 74, 47%. Outra curva entre pacientes com transtornos afetivos e controles apresentou escore depressivo com AUC de 0,869. O escore depressivo acima de 35 teve sensibilidade de 82.98% e especificidade de 75%. A energia maníaca e o humor maníaco foram os subdominios que melhor distinguiram os bipolares de unipolares através de uma análise discriminante passo a passo progressiva. A correlação parcial entre domínios e subdomínios, controlados por sexo e idade, medida pelo alfa de Cronbach, variou entre 0.472 to 0.937.Concluímos que a SCI-MOODS - VP apresenta boa validade discriminante e confiabilidade. / The SCI-MOODS (Structured Clinical Interview for Mood Spectrum) is a 161 questions questionnaire with seven sub domains (depressive and manic mood, depressive and manic energy, depressive and manic cognitive functioning and rhythmicity) that evaluates mood as a dimensional construct allowing a more precise mood disorder diagnosis. We developed the SCI-MOODS-VP, a Brazilian Portuguese version, and established its validity and reliability, and determined a threshold score for differentiation between bipolar from unipolar and affective patients from non-affective controls. The English 3.0 version of SCI-MOODS was translated to Brazilian Portuguese and back-translated. Bipolars (n=47), unipolars (n=47) and schizophrenics (n=18) patients, and 22 subjects without psychiatric diagnostic according to SCID-I/P were selected. A forward stepwise discriminant analysis among bipolars and unipolars sub domains and two ROC curves to determine the bipolar threshold were done. The internal consistency of SCI-MOODS-VP domains and sub domains was 0, 86 to 0, 94. The interater reliability among 10 bipolar and 10 unipolar subjects had an intraclass coefficient of 0,956. The bipolar subjects had total and manic scores higher than other groups. A receiver operating characteristic (ROC) curve of manic score between bipolar and unipolar subjects had an area under curve (AUC) of 0,909. The manic score equal xix or above 30 had a 91, 49% sensibility and 74, 47% specificity. Other ROC curve between patients with affective disorders and controls (without psychiatric diagnostic and schizophrenics) had a depressive score with AUC of 0,869. The depressive score equal or above 35 had an 82, 98% sensibility and a 75% specificity. The manic energy and mood were the sub domains that best distinguished bipolar and unipolar subjects by discriminant analysis. The partial correlation among domains and subdomains, controlled by age and gender, measured by Cronbach\' s alpha, was 0,472 to 0,93. SCI-MOODS-VP has good reliability and discriminant validity.
150

Toracometria em crianças com distrofia muscular de Duchenne: refinamento de metodologia de avaliação / Thoracic cirtometry in children Duchenne muscular distrophy: refinement of evaluation methodology

Agenor Garcia Junior 02 February 2012 (has links)
Contextualização: A toracometria é uma técnica simples e acessível para avaliar mobilidade do tórax durante respiração forçada, mas não permite analisar os movimentos compensatórios utilizados por portadores de doenças crônicas, como a distrofia muscular de Duchenne (DMD), caracterizada pela degeneração progressiva e irreversível da musculatura esquelética. Objetivos: Ampliar a técnica de toracometria, permitindo avaliação das compensações posturais, analisar a confiabilidade da ferramenta e, descrever a mobilidade torácica de crianças com DMD, durante respiração profunda. Métodos: Participaram 60 meninos, 30 com DMD (10,1±0,5 anos) e 30 saudáveis (9,5±0,6 anos). Aplicou-se a técnica de toracometria expandida em duas fases: livre movimentação corporal, permitindo avaliação de compensações posturais (toracometria livre) e, bloqueio de movimentos compensatórios, facilitando análise de movimentos do gradil costal (toracometria dirigida). Esta técnica prevê filmagem e observação sistemática dos movimentos, gerando dados numéricos e descritivos permanentes. O estudo de confiabilidade da técnica foi realizado nos dois grupos. Resultados: As medidas de toracometria axial e xifóide (livre e dirigida) apresentaram excelente confiabilidade intra e interexaminadores. As medidas coletadas apresentaram diferenças significantes entre os grupos. Nas crianças com DMD, a toracometria livre apresentou valor de expansibilidade torácica maior, mostrando que as compensações facilitam a mobilidades da caixa torácica. A técnica de toracometria livre apresentada permitiu a descrição de compensações posturais, sendo que as observadas com maior frequência foram os movimentos associados de cabeça, ombro e tórax. Conclusões: A técnica de toracometria expandida apresentou excelente confiabilidade e permitiu descrever os movimentos do tórax e dos arcos costais. Sugere-se sua utilização na avaliação respiratória de crianças com DMD / Background: Thoracic cirtometry is a simple and accessible technique to assess chest mobilization during forced breathing, but does not allow to analyze compensatory movements commonly used by people with chronic diseases, such Duchenne muscular dystrophy (DMD), characterized by progressive degeneration of musculoskeletal system. Objectives: To expand the technique of thoracic cirtometry to allow assessment compensatory movements, to analyze the reliability of the tool and to describe thoracic mobility of children with DMD. Methods: Participated 60 boys, 30 with DMD (10.1 ± 0.5 years) and 30 healthy (9.5 ± 0.6 years). The expanded thoracic cirtometry was organized in two phases: body can move freely, allowing the assessment of postural compensations (free thoracic cirtometry) and with postural movements blocked, facilitating the analysis of movements of the rib cage (conducted thoracic cirtometry). This technique provides systematic observation and recording of body movements, creating descriptive and numeric permanent data. We investigated repeatability and reproducibility. Results: Measures of axial and the xiphoid thoracic cirtometry (free and conducted) showed excellent reliability. All measures showed significant differences between groups. In the DMD boys, free thoracic cirtometry presented a greater value, which probably occurs due to postural compensations. The most commons were movements of head, shoulder and chest. Conclusions: The expanded thoracic cirtometry technique showed excellent reliability and achieved the objectives of determining values related to ribs mobility during deep breath, and to describe compensatory movements. We suggested its use in respiratory evaluation of children with DMD

Page generated in 0.1331 seconds