• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2279
  • 56
  • 33
  • 14
  • 14
  • 13
  • 12
  • 9
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 2399
  • 1188
  • 410
  • 401
  • 320
  • 269
  • 247
  • 180
  • 173
  • 151
  • 134
  • 129
  • 119
  • 118
  • 110
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
691

Transtorno de pânico subtipo respiratório e não respiratório: diferenças na avaliação ergoespirométrica e esquiva de atividade física / Panic disorder respiratory and non-respiratory subtype: differences exercise test in the evaluation and avoidance of physical activity

Muotri, Ricardo Willian 16 August 2010 (has links)
INTRODUÇÃO: A busca por subtipos clínicos com melhor resposta terapêutica a tratamentos específicos levou à descrição do transtorno de pânico subtipo respiratório. A qualidade de vida de pacientes com transtorno de pânico (TP) é prejudicada devido a agorafobia, a mais freqüente das conseqüências do TP não tratado. Apesar de ser uma forma de esquiva, há poucos estudos sobre esquiva de atividade física e TP. OBJETIVO: Identificar se uma população com sintomas predominantemente respiratórios apresenta esquiva de atividade física e verificar as diferenças fisiológicas no exame clínico de ergoespirometria desta população, em comparação a pessoas sem transtorno de pânico e com transtorno de pânico subtipo não respiratório. MÉTODOS: Foram selecionados casos novos consecutivos registrados no Ambulatório de Ansiedade do Instituto de Psiquiatria do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, que apresentavam diagnóstico de transtorno de pânico. Foram submetidos a diferentes questionários e a um teste ergoespirométrico. Aqueles que preencheram os critérios de inclusão e sem os critérios de exclusão foram dispostos em três grupos: 1) grupo de participantes com transtorno de pânico respiratório (TPR), 2) grupo de participantes com transtorno de pânico não respiratório (TPNR) e 3) grupo de participantes sem diagnóstico psiquiátrico (C). RESULTADOS: 1) Observou-se uma proporção maior de mulheres (63,9%) e uma média de faixa etária de 34,14 anos. 2) Os grupos TPNR e TPR apresentam uma diferença na auto avaliação 3) Para qualidade de vida, o componente físico difere estatisticamente (p 0,001), nos dois grupos, TPNR e TPR em relação ao grupo controle (C). Entretanto entre os mesmos (TPNR e TPR) não houve diferenças, apresentando como médias +- desvio padrão (DP), de 64,94 +- 16,53 e 62,80 +- 17,89 respectivamente, (p = 0,906). 4) A maior diferença à esquiva de atividade física encontra-se entre o grupo C e os outros dois grupos: TPNR e TPR, (p 0,001) principalmente em relação ao medo de praticar exercícios. 5) Ocorreu um consumo máximo de oxigênio (VO2máx.), inferior nos grupos TPNR e TPR em relação ao grupo C, valores de VO2máx. são menores no grupo TPR em comparação ao grupo C, (p = 0,029), com médias +- DP, de 27,47 +- 4,08 e 32,13 +- 5,81 respectivamente, de acordo com o nível de aptidão funcional cardiorrespiratória e metabólica. CONCLUSÕES: Existem evidências da utilidade do conceito de TPR para caracterizar um subgrupo de pacientes com transtorno de pânico. Esquiva de atividade física parece não ser um fator determinante para os subtipos de TP, embora se apresente como característica fundamental nos pacientes com transtorno de pânico. Isto sugere a utilização do exercício como uma alternativa de tratamento ainda a ser estudada, como uma exposição terapêutica. Diferenças fisiológicas de VO2máx. no teste ergoespirométrico entre os grupos TPR e TPNR, não foram significativas, mas em relação a indivíduos sem transtorno de pânico, apresentaram resultados piores no consumo máximo de oxigênio, principalmente por uma questão comportamental de condicionamento ao medo, do que em relação a fisiopatologia do TP. Como uma hipótese: os valores mais baixos de VO2máx., apresentados pelo TPR em relação ao C, devem-se ao fato de um possível aumento do grau de sedentarismo apresentado em TPR, como decorrência do TP e pela má interpretação da escala de Borg utilizada como identificação subjetiva de esforço, determinante na conclusão do teste ergoespirométrico, porém estas conclusões devem ser melhores analisadas em um projeto futuro / INTRODUCTION: The search for subtypes with better therapeutic response to specific treatments led to the description of the respiratory panic disorder subtype. The quality of life of patients with panic disorder (PD) is impaired due to agoraphobia, the most frequent consequences of untreated PD. OBJECTIVE: Identify whether a population with mainly respiratory symptoms presents avoidance of physical activity and verify physiological differences in clinical examination of ergoespirometry in this population, in comparison with people who do not have panic disorder and people with non-respiratory panic disorder subtype. METHODS: patients selected consecutive new cases recorded in Anxiety Outpatient Department of Psychiatry Institute at Hospital das Clínicas from University of São Paulo School of Medicine, who presented a diagnosis of panic disorder. They answered to different questionnaires and underwent an ergoespirometric test. Those who met the inclusion criteria and no exclusion criteria were assigned to three groups: 1) group of participants with respiratory panic disorder (RPD), 2) group of participants with non-respiratory panic disorder (NRPD), and 3) group of participants with no psychiatry diagnosis (C). RESULTS: 1) A higher ratio of women was observed (63,9%) and mean age group of 34,14 years old. 2) NRPD and RPD presented a difference in self-evaluation. 3) As regards to quality of life, the physical component statistically differs (p 0,001) in both groups, NRPD and RPD relative to control group (C). However between these groups (NRPD and RPD) there been no differences at all, showing as averages +- standard deviation (SD) 64,94 +- 16,53 and 62,80 +- 17,89 respectively, (p = 0,906). 4) The higher difference in avoidance of physical activity was found among group C and the order two groups: NRPD and RPD, (p 0,001) mainly related to fear of practicing physical activity. 5) It was observed lower maximum oxygen uptake (VO2 máx.) in NRPD and RPD groups relative to group C, VO2 máx. Is lower in RPD group in comparison to group C, (p = 0,029), with averages +- SD 27,47 +- 4,08 and 32,13 +- 5,81 respectively, according to the level of metabolic and cardiorrespiratory performance status. CONCLUSIONS: There are evidences of the utility of RPD concept to characterize a subgroup of patients with panic disorder. Avoidance of physical activity does not seen a determining factor to PD subtypes, although it is presented as an essential characteristic in panic disorder patients. This suggests the use of physical activity as a treatment alternative to be studied, as a therapeutic exposition. Physiological differences in VO2 máx during ergoespirometric test between RPD e NRPD groups were not significant, but as regards to individuals with no panic disorder, they presented worse results in maximum oxygen uptake mainly due to a behavioral reason of being conditioned to fear, rather than PD physiopathology. As a hypothesis: lower VO2 máx values observed in RPD, arising from PD and from misinterpretation of Borg scale, which is subjectively used to identify the effort, and is a determining factor to obtain a conclusion of ergoespirometric test, however such conclusions must be further analyzed in a future project
692

Validação de teste de esterilidade baseado em detecção de dióxido de carbono / Validation of sterility test based in carbon dioxide detection

Lira, Rodolfo Santos de 09 April 2014 (has links)
De acordo com compêndios farmacêuticos, o teste de esterilidade, requer período de incubação de 14 dias para obtenção de resultado analítico, período em que produto farmacêutico é mantido em quarentena, o que demanda custos elevados. Os métodos alternativos com aplicação na avaliação da esterilidade são particularmente interessantes, quando possibilitam a redução do período de incubação do teste, o período de quarentena e, em consequência, os custos envolvidos, além de reduzir o tempo para preparação do material requerido, para execução do ensaio e para a capacitação técnica. O presente estudo avaliou o desempenho do método microbiológico rápido BacT/Alert 3D (Biomerieux®) aplicado ao teste de esterilidade em comparação ao teste de esterilidade por método indireto descrito nas farmacopeias (brasileira, americana, européia e japonesa). O Bact/Alert 3D se baseia na detecção do crescimento microbiano, que é feita por meio de detecção de alteração da cor de um sensor sensível à liberação de dióxido de carbono produzido por metabolismo microbiano. Os testes utilizaram três diferentes soluções parenterais de grande volume: solução salina 0,9%, concentrado polieletrolítico para diálise e solução de metronidazol. Micro-organismos desafio: Escherichia coli ATCC 8739, Pseudomonas aeruginosa ATCC 9027, Staphylococcus aureus ATCC 6538, Bacillus subtilis ATCC 6633, Clostridium sporogenes ATCC 19404, Candida albicans ATCC 10231 e Aspergillus brasiliensis ATCC 16404. Cargas de contaminação: 20, 2 e 0,2 UFC/membrana. Temperatura de incubação: 32,5 ± 0,5 °C. As amostras foram avaliadas por 14 dias. Amostras dos três produtos foram artificialmente contaminadas com BioBalls® SingleShot dos micro-organismos desafio de diferentes cargas de contaminação foram submetidas ao teste de esterilidade farmacopeico, com inoculação por método indireto. Após 18h de incubação, foram retiradas alíquotas de cada um dos meios de cultura, que foram inoculadas nos frascos de meio de cultura do BacT/Alert 3D. Bact/Alert 3D demonstrou equivalência ao método farmacopeico (p > 0,05) e tempo de detecção inferior. / Nowadays, the harmonized sterility test method described on pharmacopoeias requires an incubation period of 14 days. During this period the product stays on quarantine waiting the result for release, which demands warehousing and inventory costs. The application of Rapid microbiologial methods for sterility testing is particulary interesting considering the benefits of incubation time reduction, quarantine period reduction, time reduction for material preparation, reduction of time for test execution and technical training.This work evaluated comparetivelly the performance of Bact/Alert 3D system as a rapid microbiologial method applied to sterility testing and sterility testing according to described on Brazilian pharmacopeia and harmonized pharmacopeias (American pharmacopeia, European pharmacopeia and Japanese pharmacopeia). The Bact/Alert 3D is based on microrganisms gowth and has as principle the detection of pad color change which is sensible to carbon dioxide release by microorganism metabolism. To perform the evaluation it was considered Buffer saline solution, Metronidazol solution and Polieletrolitic dialysis concentrate solution. Challenge Microrganisms: Staphylococcus aureus (ATCC 6538), Bacilus subtilis (ATCC 6633), Pseudomonas aeruginosa (ATCC 9027), Escherichia coli (ATCC 8739 ), Clostridium sporogenes (ATCC 19404), Candida albicans (ATCC 10231) and Aspergillus brasiliensis (ATCC 16404). Inoculum load: 20CFU/sample; 2 CFU/sample; 0,2CFU/sample. Incubation temperature: 32,5 ± 0,5 °C. The samples were evaluated during 14 days. Aseptic samples of the three products were intentionally contaminated with BioBalls® SingleShot of challenge microorganisms, according to inoculum concentration desired, and were tested by indirect inoculation. After 18h aliquotes of were taken from inoculated culture media and inoculated into BacT/Alert 3D culture media bottles. Bact/Alert showed equivalence to compendial method (p > 0,05) and showed results faster than compendial method.
693

Composição e estabilidade do leite de vacas alimentadas com dieta aniônica / Milk stability and composition of cows fed anionic diet

Martins, Cristian Marlon de Magalhães Rodrigues 16 December 2014 (has links)
O presente estudo objetivou avaliar o efeito do balanço cátion-aniônico da dieta sobre: (a) concentração de subunidades de caseína, proteínas do soro, cálcio iônico e estabilidade do leite ao etanol e ao aquecimento a 140º C; (b) metabolismo digestivo, renal e sanguíneo de vacas leiteiras em lactação. Foram utilizadas 16 vacas da raça Holandês, com 158 ± 52 dias em lactação, distribuídas em 4 quadrados contemporâneos em um delineamento Quadrado Latino 4 x 4, com 4 períodos de 21 dias e 4 tratamentos. Os tratamentos experimentais consistiram de 4 níveis de balanço cátion-aniônico da dieta (BCAD): +290; +192; +98 e -71 mEq/kg de MS. No presente estudo, o consumo de matéria seca, as concentração de ácidos graxos de cadeia curta (AGCC) e o pH do fluído ruminal, e a digestibilidade aparente total da FDN aumentaram de acordo com o aumento do BCAD. De forma semelhante, a produção de leite corrigida para gordura, e os teores de gordura, lactose, e sólidos totais do leite aumentaram linearmente em 13,52, 8,78, 2,5 e 2,6%, respectivamente, quando o BCAD aumentou de -71 para 290 mEq/kg MS; enquanto que os teores de proteína bruta e de caseína reduziram linearmente em 4,83 e 4,49%, respectivamente. Adicionalmente, a concentração sanguínea de HCO3- o pH do sangue e a excreção urinária de Na e K aumentaram de acordo com o BCAD, o que reduziu as concentrações sanguíneas de cátions (Na, K e Ca iônico) e, consequentemente, a concentração de Ca iônico do leite. Como resultado da redução da concentração de Ca iônico, a estabilidade do leite ao etanol e ao aquecimento a 140º C aumentaram linearmente com o BCAD [Y = 74,87 (EP = 0,87) + 0,01174 (EP = 0,0025) × BCAD (mEq/kg MS) e Y = 3,95 (EP = 1,02) + 0,01234 (EP = 0,0032) × BCAD (mEq/kg MS), respectivamente]. Desta forma, pode-se concluir que o BCAD aumenta o desempenho produtivo de vacas leiteiras em lactação e, adicionalmente, eleva a capacidade relativa das proteínas do leite em resistir à coagulação ao teste do álcool e durante o aquecimento do leite a 140º C. / The present study aimed to evaluate the effect of dietary cation-anion difference (DCAD) on: (a) concentrations of casein subunits, whey proteins, ionic calcium, and milk ethanol and heat stability at 140º C; (b) digestive, renal and blood metabolism of dairy cows. Sixteen Holstein cows, with 158 ± 52 days in milk, were distributed in 4 contemporary 4 x 4 Latin Square design, with four periods of 21 days and 4 treatments. The experimental treatments consisted in 4 levels of dietary cation-anion difference (DCAD): +290; +192; +98 e -71 mEq/kg DM. In the present study, dry matter intake, the concentration of short chain fat acids (SCFA) and ruminal pH, and the NDF total apparent digestibility increased according to DCAD increases. Similarly, fat-corrected milk and fat, lactose and total milk solids content were linearly increased by 13.52, 8.78, 2.5 and 2.6%, respectively, according to DCAD increases from -71 to 290 mEq/kg DM; while crude protein and casein content were linearly reduced by 4.83 and 4.49%, respectively. In addition, blood concentration of HCO3-, o pH of blood, and urinary excretion of Na and K increased according to DCAD, which reduced the blood concentrations of cations (Na, K and ionic Ca) and, consequently, the milk concentrations of ionic Ca. As a result of reduction of ionic Ca concentration, the milk ethanol and heat stability at 140º C linearly increased with DCAD [Y = 74.87 (SE = 0.87) + 0.01174 (SE = 0.0025) × DCAD (mEq/kg DM) and Y = 3.95 (SE = 1.02) + 0.01234 (SE = 0.0032) × DCAD (mEq/Kg DM), respectively]. Thus, it may be concluded that DCAD increases the productive performance of lactating dairy cows and, additionally, increases the relative capacity of milk proteins to resist the coagulation at alcohol test and during heat treatment at 140º C.
694

Perfil sensorial e aceitabilidade de suco de laranja integral pasteurizado e suco de laranja reconstituido / Sensorial profile and acceptability of orange juice pasteurized and orange juice reconstituted

Jordão, Fabiana Galvani 30 January 2006 (has links)
As indústrias têm deixado de produzir o suco de laranja integral pasteurizado em substituição ao suco de laranja reconstituído devido, principalmente, à dificuldade em se produzir esse tipo de suco durante todo o ano com as mesmas características. Esse trabalho objetivou avaliar sensorialmente esses dois tipos de sucos. Sete provadores selecionados e treinados avaliaram a aparência, aroma, sabor e textura de amostras de suco de laranja utilizando a Análise Descritiva Quantitativa (ADQ). O teste de aceitação pelo consumidor foi realizado com cento e um provadores não treinados, utilizando a escala hedônica e um mapa de preferência foi traçado. A ADQ mostrou que houve diferenças significativas (p<0,05) em relação a: cor amarela, concentrado, aroma laranja, aroma de sumo, sabor de laranja, sabor passado, sabor cozido. Entretanto, não houve diferenças significativas (p>0,05) entre as amostras do suco em relação a: aroma cítrico, aroma cozido, aroma doce, sabor sumo, gosto doce, gosto ácido e encorpado. O suco reconstituído apresentou os atributos com maior intensidade para cor amarela, concentrado, aroma de sumo, sabor passado e sabor cozido em relação ao pasteurizado enquanto esse, o aroma e sabor de laranja foram os atributos mais acentuados. O teste de consumidor indicou que os dois sucos tiveram aceitação parecidas situando-se entre os termos hedônicos indiferente e gostei ligeiramente e o resultado do mapa de preferência mostrou baixa aceitação pela grande maioria dos consumidores de suco. Os dados de HPLC não mostraram diferença entre as amostras de suco analisadas. / The industries are allowing to produce the orange juice pasteurized in substitution to the orange juice reconstituted, mainly, the difficulty in producing this type of juice during the year with the same characteristics. This work objectified to evaluate these sensorially two types of juices. Seven selected and trained panelists evaluated the appearance, aroma, flavor and texture of orange juice pasteurized and orange juice reconstituted by Descriptive Quantitative Analysis (QDA). The consumer test and a preference map was done with one-hundred one non-trained panelists through the hedonic test. The QDA showed significant differences (p<0,05) concerning yellow color, concentrate, orange odor, the highest point odor, orange flavor, passed flavor and cooked flavor. However, there was no significant difference (p>0,05) concerning: citric aroma, candy aroma, cooked aroma, supreme flavor, candy taste, acid taste and viscosity. The reconstituted juice presented the attributes with bigger intensity for yellow color, concentrate, the highest point aroma, last flavor and flavor cooked in relation to the pasteurized and this juice, the aroma and flavor of orange had been the more accented attributes. The consumer test indicated that orange juice pasteurized and orange juice reconstituted were acceptance similar placing itself enters the hedonic terms indifferent and liked slightly and the result of the preference map showed low acceptance by majority of the juice consumers. The HPLC data hadn’t shown the difference enter the analyzed juice samples.
695

Estudo comparativo entre teste rápido imunológico (LID-NDO) e PCR tempo real de raspado dérmico em álcool e em papel-filtro na hanseníase / Comparative study between immunological rapid test (LID-NDO) and real-time PCR of dermal smear in alcohol and filter paper in leprosy

Silva, Gabriela Pagano de Oliveira Gonçalves da 13 March 2017 (has links)
A hanseníase é uma doença infecciosa que acomete pele e nervos periféricos. Seu diagnóstico é baseado eminentemente nos seus aspectos clínicos variáveis e poucos são os exames complementares que auxiliam no diagnóstico, como baciloscopia do raspado intradérmico, histopatologia, ELISA anti- PGL1 (APGL1) e anti-LID, geralmente positivos nas formas multibacilares, dificultando o diagnóstico das formas paucibacilares. Busca-se comparar os resultados obtidos com o teste rápido imunológico (LID-NDO) Orange Life® com os resultados da PCR tempo real realizada nas amostras de raspado intradérmico e os resultados do ELISA APGL1 coletadas durante a ação por demanda espontânea (Hanseníase Brasília 2014), além de comparar eficiência entre dois métodos diferentes de conservação destas amostras (papel-filtro x álcool). Foram coletadas 277 amostras de raspado dérmico de 50 pacientes clinicamente diagnosticados com hanseníase durante a ação. Na mesma ocasião, os indivíduos diagnosticados foram submetidos à coleta de sangue periférico para teste rápido sorológico (Orange Life®) e ELISA APGL1. A extração de DNA do raspado intradérmico, armazenado no álcool e no papel-filtro, foi realizada no Laboratório de Dermatologia do HC-FMRP-USP. A PCR em tempo real foi realizada usando par de primers específicos RLEP, e o master mix sybr greenPromega. Dos 50 pacientes diagnosticados clinicamente, 90% são multibacilares. Todos os testes, tanto o teste rápido sorológico como a PCR, apresentaram maior positividade nos pacientes multibacilares. O teste rápido sorológico foi positivo em 64,44% dos pacientes multibacilares e em 40% dos paucibacilares. A PCR nas amostras armazenadas no álcool foi positiva em 19,05% dos pacientes multibacilares e a PCR do papel-filtro em 17,78%; nenhuma PCR foi positiva em pacientes paucibacilares. O ELISA APGL foi positivo em 56% dos pacientes diagnosticados. Na PCR das amostras armazenadas no papel-filtro, o sítio de coleta com maior positividade foram os cotovelos (75%). A concordância entre o teste rápido sorológico e a PCR e a concordância entre o teste rápido e o ELISA APGL1 foram fair (suave). Já a concordância entre a PCR das amostras armazenadas no álcool e a PCR das amostras armazenadas no papel-filtro foi perfeita. Concluímos que o exame clínico é ainda essencial para o diagnóstico da hanseníase, principalmente das formas paucibacilares. Os métodos de armazenamento do material coletado por raspado intradérmico (papel-filtro x álcool) não interferiram no resultado final da PCR, portanto o armazenamento no papel-filtro pode ser feito preferencialmente, pois apresenta menor custo para a extração de DNA. O teste rápido sorológico e o ELISA anti-PGL1 têm baixa especificidade, porém podem ter outras aplicações, diferentes do diagnóstico da hanseníase. / Leprosy is an infectious disease that affects skin and peripheral nerves. Leprosy diagnosis is mainly based on its variable clinical aspects and few complementary tests that aid in the diagnosis, such as bacilloscopy, histopathology, besides the antiPGL1 ELISA (APGL1) and anti-LID, all of which are generally positive in multibacillary forms, confirming the difficulty in diagnosis of paucibacillary patients. The aim of this study was to compare the results obtained with the Orange Life® Immunological Rapid Test (LID-NDO) with the real-time PCR results obtained in the intradermal scraping samples and the results of the ELISA APGL1, collected during the \"Hanseníase\" action in Brasília in January 2014, in addition to comparing efficiency between two different methods of preservation of these samples (filter paper x alcohol). A total of 277 dermal smear samples were collected from 50 patients clinically diagnosed with leprosy during the procedure. At the same time, the individuals diagnosed were submitted to peripheral blood collection for serological rapid test (Orange Life®) and ELISA APGL1. The extraction of DNA from intradermal scrapings, stored in alcohol and filter paper, was carried out at the Dermatology Laboratory of HC-FMRP-USP. Real-time PCR was performed using a pair of primers specific for the RLEP gene, and the master sybr green-Promega. From 50 patients diagnosed clinically, 90% are multibacillary. All tests, both the serological rapid test and the PCR, were more positive in multibacillary patients. The rapid serological test was positive in 64.44% of the multibacillary patients, and in 40% of the paucibacillary. The PCR in the samples stored in the alcohol was positive in 19.05% of the multibacillary patients and the PCR of the filter paper in 17.78%; PCR weren\'t positive in paucibacillary patients. ELISA APGL was positive in 56% (28) of the diagnosed patients. In the PCR of the samples stored in the filter paper, the collection site with the highest positivity was the elbows (75%). The agreement between the rapid serological test and the PCR and the agreement between the rapid test and the ELISA APGL1 were fair. The agreement between the PCR of the samples stored in the alcohol and the PCR of the samples stored on the filter paper was perfect. We conclude that the clinical examination is still essential for the diagnosis of leprosy, especially in paucibacillary forms. We also concluded that the methods of storing the material collected by intradermal scraping (filter paper x alcohol) do not interfere in the final result of the PCR, therefore the storage in the filter paper can be done preferentially because it presents a lower cost for the extraction of DNA. Rapid serological test and the anti-PGL1 ELISA have low specificity, but may have other different applications than the diagnosis of leprosy.
696

Estudo do processo de reparo ósseo em função de quatro biomateriais. Avaliação histomorfológica em tíbia de coelhos / Study of bone repair process in function of four biomaterials. Microscopy evaluation in rabbit tibias

Cavenago, Bruno Cavalini 23 May 2011 (has links)
Este estudo avaliou o processo de reparo ósseo em cavidades cirúrgicas de tamanho não crítico, quando preenchidas por diferentes biomateriais. Um defeito ósseo de 5 mm de diâmetro por 8mm profundidade foi criado em cada metáfise tibial de 27 coelhos machos. Foram estabelecidos 4 grupos com 12 cavidades por material. As cavidades foram preenchidas com matriz óssea bovina inorgânica, GenOx Inorg® (grupo 1), matriz óssea bovina orgânica, GenOx Org® (grupo 2), matriz óssea bovina composta, GenMix® (grupo 3) e sulfato de cálcio di-hidratado (Grupo 4). Adicionalmente, seis cavidades preenchidas com coágulo sanguíneo foram utilizadas como controle (grupo 5). Os animais foram mortos após 30, 60 e 90 dias e as amostras coletadas foram submetidas ao processamento histotécnico para obter cortes de 5 m de espessura, corados com hematoxilina e eosina. Foram realizadas análises histomorfológica descritiva e histomofométrica, que consistiu na mensuração da área de tecido ósseo neoformado. Os dados obtidos foram submetidos ao teste estatístico de Kruskal-Wallis e Dunn. Aos 30 e 60 dias a área de tecido ósseo neoformado ocorreu de forma semelhante entre todos os grupos (P > 0,05). No período de 90 dias houve diferença significativa entre os grupos 2 e 4, bem como entre os grupos 4 e 5. Ao realizar a análise estatística de cada grupo em função dos 3 períodos experimentais, constatou-se que nos grupos 1, 2 e 3 a área de tecido ósseo neoformado aos 30 dias foi menor (P < 0,05) em relação a 60 e 90 dias. No grupo 4, ocorreu diferença significativa entre os períodos de 30 e 90 dias, já no grupo 5 houve diferença significante ao comparar 30 e 60 dias. Com base na microscopia observamos que os biomateriais estudados não inibiram o processo de reparo; o GenOx Inorg e a matriz inorgânica presente no GenMix exibiram características morfológicas de propriedade osteocondutora, mais intensa no primeiro grupo. O GenOx Org e o sulfato de cálcio di-hidratado apresentaram-se completamente reabsorvidos aos 30 dias. Foi possível concluir que os valores neoformativos proporcionados pelo GenMix não foram significativamente superiores, àqueles obtidos pelo GenOx Inorg, GenOx Org e sulfato de cálcio di-hidratado. Os diferentes biomateriais utilizados não apresentaram resultados superiores ao coágulo sanguíneo, exceto o sulfato de cálcio di-hidratado aos 90 dias. / This study evaluated the bone healing process in non-critical surgical cavity size, when grafted with different biomaterials. A 5mm wide and 8mm long defect were created in each tibial metaphysis of 27 male rabbits. Four groups of 12 cavities per material were established. The cavities were filled with deproteinized bovine bone, GenOx Inorg ® (group 1), demineralized bovine bone, GenOx Org® (group 2), composite bovine bone, GenMix® (group 3) and di-hydrate calcium sulfate (group 4). Additionally 6 cavities were filled with blood clot for control purposes (group 5). At 30, 60 and 90 days after surgery the animals were killed and the grafted areas were submitted to histologically process to obtain a 5 m thickness sections and stained with hematoxylin and eosin. The specimens were proceeded to descriptive and quantitative microscopic analysis, by measuring the area of new formed bone. The results were statistically analyzed by the Kruskal-Wallis and Dunn tests. At 30 and 60 days the area of new bone formation was similar among all groups (P > 0,05). In 90 days period there was a significant difference between groups 2 and 4, as well as groups 4 and 5. Performing the statistical analysis of each group in relation to the 3 experimental periods, it was found that in groups 1, 2 and 3 the area of new bone formed at 30 days was lower (P < 0,05) than 60 and 90 days. There was a significant difference in group 4 comparing the periods 30 and 90 days and in group 5 between 30 and 60 days. Based on microscopy findings we observed that the biomaterials studied did not inhibit the repair process; the GenOx Inorg and inorganic matrix present in GenMix exhibited morphological characteristics of osteoconductive property, more intense in the first one. The GenOx Org and di-hydrate calcium sulfate were completely reabsorbed within 30 days. It was concluded that the values of new bone formed area provided by GenMix were not significantly higher than obtained by GenOx Inorg, GenOx Org and di-hydrate calcium sulfate. The different biomaterials used did not show better results than blood clot, except di-hydrate calcium sulfate at 90 days.
697

Teste de desempenho escolar (TDE-II) : valida??o do subteste de escrita e constru??o do sistema de corre??o do subteste de escrita

Sartori, M?rcia Santos 13 March 2017 (has links)
Submitted by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-06-30T18:42:15Z No. of bitstreams: 1 DIS_MARCIA_SANTOS_SARTORI_PARCIAL.pdf: 392876 bytes, checksum: 924d61414c003df5ac8874dd0d8c9b26 (MD5) / Made available in DSpace on 2017-06-30T18:42:15Z (GMT). No. of bitstreams: 1 DIS_MARCIA_SANTOS_SARTORI_PARCIAL.pdf: 392876 bytes, checksum: 924d61414c003df5ac8874dd0d8c9b26 (MD5) Previous issue date: 2017-03-13 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / This dissertation is composed of two studies that aimed at the construction of a Correction System and the search for evidence of validity of the Writing Subtest of the TDE-II. The first deals with the development of the Correction System over four stages and the analysis of six expert judges. The first stage included the analysis of the methods of correction of national and international instruments that evaluate the written production. From the results of this analysis, in the second one the guiding criteria were defined for the construction of the preliminary version of the Correction System, being proposed categories for the classification in micro and macro-structure of the word. In the third stage, the preliminary version of the Correction System was constructed, based on the parameters of step 2. The fourth step was the last analysis of the preliminary version. After that, two correction screens were created: one for students from 1st to 4th year (Version A) and another for students from 5th to 9th grade (Version B), as well as a manual with guidelines for the evaluators. The second study tested evidence of validity, of the convergent type, of the Writing Subtest. 160 students from public and private schools in Porto Alegre / RS and metropolitan region participated. The results showed that the scores of the two versions presented moderate and strong correlations with the tasks of oral language, reading and writing. The dissertation was completed resulting in the Correction System of the Writing Subtest of the TDE-II, as well as obtaining evidence of convergent validity of the Writing Subtest of the TDE-II. / Esta disserta??o de mestrado ? composta por dois estudos que objetivaram a constru??o de um Sistema de Corre??o e a busca de evid?ncias de validade do Subteste de Escrita do TDE-II. O primeiro aborda o desenvolvimento do Sistema de Corre??o ao longo de quatro etapas e a an?lise de seis ju?zes especialistas. A primeira etapa compreendeu a an?lise dos m?todos de corre??o de instrumentos nacionais e internacionais que avaliam a produ??o escrita. A partir dos resultados dessa an?lise, na segunda definiram-se os crit?rios norteadores para a constru??o da vers?o preliminar do Sistema de Corre??o sendo propostas categorias para a classifica??o em micro e macroestrutura da palavra. Na terceira etapa houve a constru??o da vers?o preliminar do Sistema de Corre??o, com base nos par?metros da etapa 2. A quarta etapa constituiu a ?ltima an?lise da vers?o preliminar. Ap?s, originaram-se dois crivos de corre??o: um para estudantes de 1? a 4? ano (Vers?o A) e outro para estudantes de 5? a 9? ano (Vers?o B) al?m de um manual com orienta??es aos avaliadores. O segundo estudo testou evid?ncias de validade, do tipo convergente, do Subteste de Escrita. Participaram 160 estudantes de escolas p?blicas e privadas de Porto Alegre/RS e regi?o metropolitana. Os resultados apontaram que os escores das duas vers?es apresentaram correla??es moderadas e fortes com as tarefas de linguagem oral, leitura e escrita. A disserta??o foi conclu?da tendo como resultado o Sistema de Corre??o do Subteste de Escrita do TDE-II, bem como a obten??o de evid?ncias de validade convergente do Subteste de Escrita do TDE-II.
698

Triagem cognitiva nas doenças cerebrovasculares : processo de construção e propriedades psicométricas do instrumento TRIACOG / Cognitive screening in cerebrovascular diseases : construction process and psychometric properties of the TRIACOG instrument

Rodrigues, Jaqueline de Carvalho January 2017 (has links)
Esta tese de doutorado aborda aspectos teóricos e empíricos da avaliação neuropsicológica nas doenças cerebrovasculares, ao propor a construção de um instrumento do tipo triagem cognitiva. A tese foi dividida em quatro estudos. O Estudo 1 apresenta etapas e critérios necessários para construir e adaptar instrumentos neuropsicológicos. Nesse estudo, destacouse que ao construir um teste é importante ter uma teoria que embase o desenvolvimento dos itens, além do aporte da psicometria, neuropsicolinguística, psicologia experimental e modelos de processamento da informação. O Estudo 2 trata de uma revisão sistemática que analisou as propriedades psicométricas dos instrumentos neuropsicológicos aplicados em amostras com AVC e o desempenho dos pacientes nesses estudos. Concluiu-se que muitas pesquisas utilizam instrumentos desenvolvidos com o propósito de avaliar pacientes com demência, pouco sensíveis para adultos pós AVC. Os principais déficits cognitivos dessa doença envolvem a velocidade do processamento, visuoconstrução, memória episódica, atenção e funções executivas, que devem ser incluídas em baterias de avaliação neuropsicológica. No Estudo 3 investigou-se empiricamente quais tarefas mostram-se importantes para avaliar pacientes pós AVC. Ao analisar o desempenho por itens em um instrumento de avaliação neuropsicológica breve, identificou-se que tarefas de orientação, linguagem oral, habilidades acadêmicas (leitura, escrita e aritmética) e funções executivas melhor discriminam entre grupos com AVC e saudáveis. O Estudo 4 apresenta o processo de construção e as propriedades psicométricas da Triagem Cognitiva (TRIACOG) para avaliar adultos com doenças cerebrovasculares. O TRIACOG passou por etapas rigorosas de revisão da literatura, análise de juízes, estudos piloto e aplicação em 100 adultos pós AVC e 100 adultos neurologicamente saudáveis. O instrumento apresenta evidências de validade baseadas no conteúdo, na relação com outras variáveis (critério e validade convergente), no processo de resposta; e evidências de fidedignidade teste-reteste e entre avaliadores. Espera-se que esses estudos possam orientar pesquisadores que pretendem construir instrumentos neuropsicológicos e contribuir com uma ferramenta que pode ser utilizada no contexto clínico, hospitalar e de pesquisa, por profissionais da saúde. / This doctoral dissertation discusses theoretical and empirical aspects of the neuropsychological assessment in cerebrovascular diseases, proposing the construction of a cognitive screening instrument. The thesis was divided into four studies. The Study 1 presents steps and criteria to construct and adapt neuropsychological instruments. In this study, was highlighted the importance to have a theoretical basis to development the items of a test, besides the contribution of psychometry, neuropsycholinguistics, experimental psychology and information processing models. The Study 2 is a systematic review that analyzed the psychometric properties of neuropsychological instruments to evaluate stroke samples and the performance of patients assessed by the studies. It was concluded that many researches use instruments developed for evaluating patients with dementia, not sensitive to adults poststroke. The main deficits of this disease involve processing speed, visuoconstruction, episodic memory, attention and executive functions, which should be included in neuropsychological batteries. The Study 3 empirically investigated which tasks are important for evaluating poststroke patients. When analyzing the performance by items in a brief neuropsychological evaluation instrument, were identified that orientation, oral language, academic abilities (reading, writing and arithmetic) and executive functions tasks best discriminated between clinical and healthy groups. The Study 4 presents the construction and the psychometric properties of Cognitive Screening (TRIACOG) to evaluate adults post cerebrovascular disease. TRIACOG has undergone rigorous steps: literature review, pilot studies, and application in 100 post-stroke adults and 100 neurologically healthy adults. The instrument presents evidence of validity based on content, on relation to other variables (criterion and convergent validity) and on response processes; and test-retest and inter-rater reliability evidences. It is intended that these studies may guide researchers who want to build neuropsychological instruments and contribute with a tool that can be used in the clinical, hospital and research contexts, by health professionals.
699

"Análise dos instrumentos de avaliação de qualidade de vida WHOQOL-bref e SF-36: confiabilidade, validade e concordância entre pacientes de Unidades de Terapia Intensiva e seus familiares" / Analysis of the WHOQOL-bref and SF-36: reliability, validity and agreement between patients of the Intensive Care Unit and their families.

Suely Sueko Viski Zanei 22 February 2006 (has links)
Este estudo teve como objetivos: analisar as propriedades psicométricas dos instrumentos de avaliação de qualidade de vida WHOQOL-bref e SF-36 aplicados a pacientes adultos após a internação em Unidades de Terapia Intensiva e a seus familiares e, avaliar a concordância entre pacientes e familiares como seus substitutos. A amostra foi composta por 71 pares paciente-famíliar. A confiabilidade foi avaliada pela consistência interna através do Coeficiente Alfa de Cronbach. A validade convergente foi avaliada através das correlações interdomínios dos instrumentos e a validade divergente pelas correlações entre os domínios e o número de comorbidades através da Correlação de Spearman. A concordância entre os pares foi verificada pelo Coeficiente de Correlação Intraclasse e pela estatística kappa ponderado. Os resultados mostraram que o SF-36 quanto à confiabilidade apresenta valores aceitáveis (0,70) para a maioria dos domínios tanto para pacientes como para os familiares. Quanto ao WHOQOL-bref o coeficiente foi inferior a 0,70 para todos os domínios, em ambos os casos. A maioria das correlações interdomínios do SF-36 foram positivas e significativas para pacientes e familiares. O WHOQOL-bref quando aplicado aos pacientes apresentou correlações interdomínios positivas e significativas, mas o mesmo não ocorreu com os familiares. As correlações entre os domínios e número de comorbidades, tanto para o SF-36 e o WHOQOL–bref não foram significativas. A concordância entre os pares foi melhor quando o familiar foi o pai ou a mãe, filho e cônjuge, nessa ordem. Domínios e itens que avaliam condições objetivas são os que apresentam valores de concordância mais elevados entre os pares. O SF-36 apresentou maior número de concordâncias moderadas. O domínio Aspectos Físicos do SF-36 foi o que apresentou concordância substancial para todos os familiares. O domínio Físico do WHOQOL-bref apresentou concordância moderada para a maioria dos familiares. Para o SF-36, a concordância foi melhor quando os pacientes tinham duas ou mais comorbidades, Para o WHOQOL-bref foi melhor quando o paciente tinha uma ou duas comorbidades, mas apresentou maior número de concordâncias inconsistentes. De forma geral, os domínios previstos como aqueles que avaliam construtos similares não se correlacionaram. Esses resultados confirmam que no contexto do tratamento intensivo o SF-36 é mais adequado como instrumento de avaliação de qualidade de vida relacionado à saúde. Esses achados são similares aos da literatura internacional. / This aims this study were: to analyze the psychometric properties of the instruments for the evaluation of Quality of Life WHOQOL-bref and Medical Outcomes Study 36-Item Short Form Health Survey (SF-36) applied to adult patients after discharged from Intensive Care Units and their families and to evaluate the agreement between patients and their families as proxies. The sample consisted of 71 patient-family pairs. The internal consistency reliability was evaluated by the Cronbach’s Alfa Coefficient. The convergent validity was evaluated by the inter-domain correlations of the instruments and a divergent validity was evaluated by Spearman correlation between domains and number of comorbidities. Intraclass Correlation Coefficient and weighted kappa were used to analise the agreement between the pairs. Cronbach’s Alpha Coefficient was acceptable (0.70) for the majority of SF-36 domains for patients and their families. For the WHOQOL-bref, the coefficients were below 0, 70 for all domains in both cases. The majority of inter-domains correlation of SF-36 for patients and proxies were positive and significant. WHOQOL-bref inter-domain correlations were positive and significant when applied to the patients but not for the families. For the correlations between domains and number of comorbidities, the majority of SF-36 and WHOQOL-bref domains did not correlate for either the patients or their families. The divergent validity was not supported in both instruments. Agreement between the pairs was better when the relatives were the parents or sons. Domains and items that evaluated objective conditions presented much higher values of agreement between the pairs. The SF-36, showed a larger number of domains with moderate agreement. The Physical Role domains of SF-36 were what showed a substantial agreement for all of the families. The Physical domain of WHOQOL-bref, showed moderate agreement between each of the family members. The agreement SF-36, was better when the patients had 2 or more comorbidities, regarding the WHOQOL-bref, it was better when a patiente had 1 or 2 comorbities, however it showed a greater number of inconsistent agreements. In general, domains hypothesized to measure similar constructs do not correlated. These results confirm that the SF-36 is more suitable for the evaluation of quality of life in the intensive care context. These findings are similar to from international literature.
700

Valor da espirometria para detecção de asma em estudos epidemiológicos / Importance of spirometry for asthma epidemiologic research.

Luciano Penha Pereira 28 February 2013 (has links)
O diagnóstico da asma baseia-se na anamnese e no exame clínico, mas provas de função pulmonar e avaliação da alergia contribuem para o diagnóstico. A espirometria é o exame complementar mais utilizado em pacientes asmáticos, por ser útil para o diagnóstico, por ser o exame mais disponível no sistema de saúde, para classificação da gravidade e para o monitoramento terapêutico. A medida da reatividade brônquica é um exame mais demorado, tem maior risco, maior custo e é menos disponível. No entanto, é superior por representar melhor a fisiopatologia da asma. Este projeto tem o objetivo de determinar o valor da espirometria na investigação de asma em estudos epidemiológicos (tendo como referência a medida de reatividade brônquica). Foram analisados os dados de 1922 indivíduos que constituíram uma coorte de nascidos em hospitais de Ribeirão Preto em 1978 e 1979. Estes indivíduos preencheram questionários, incluindo o questionário da European Community Respiratory Health Survey; foram submetidos à espirometria e ao teste de broncoprovocação com metacolina, que mede a reatividade brônquica. Para análise dos dados, a asma foi definida pela associação de teste de broncoprovocação positivo com pelo menos um dos sintomas: sibilância, aperto no peito, dispneia, dispneia noturna. A prevalência de volume expiratório forçado no primeiro segundo menor que oitenta por cento (VEF1 < 80%) do previsto (espirometria alterada ou VEF1 reduzido) foi de 10,9%, a prevalência de hiperreatividade brônquica foi de 22,2% e a prevalência de asma foi de 10,4% na amostra de 1922 indivíduos. A espirometria teve sensibilidade de 38% para detectar asma no sexo masculino e de 16% no sexo feminino com especificidades de 94% e 90%, respectivamente. Na análise univariada, houve associação entre espirometria alterada e diagnóstico de asma apenas no sexo masculino com razão de prevalência (RP) de 5,31 com intervalo de confiança de 95% de 3,60-7,83. No sexo feminino, a RP foi de 1,34 (0,87-2,07). Na análise multivariada, a associação entre espirometria alterada e o diagnóstico de asma foi evidenciada em homens pela RP de 4,20 (2,71-6,71), mas não foi evidenciada em mulheres: 1,24 (0,79-1,93). O índice Kappa entre VEF1 reduzido e asma foi de 0,13 (0,08 - 0,19). Portanto, empregando-se o teste de broncoprovocação com sintomas para definir asma, a espirometria demonstra limitações, como baixa sensibilidade, fraca concordância e diferenças na capacidade de detectar asma entre homens e mulheres. / The diagnosis of asthma is based on history and clinical examination, but pulmonary function tests and allergy evaluation contribute to diagnosis. Spirometry is the most used complementary test in patients with asthma because it is useful and the most available in medical routine to classify the severity and therapeutic monitoring. Measurement of bronchial reactivity is more time consuming, has a higher risk, higher cost and lower availability. However, it is thought to be superior because it represents the pathophysiology of asthma. This project aims to determine the value of spirometry for asthma screening in epidemiological studies (as compared with bronchial reactivity measurement). Data from 1922 individuals who comprised a cohort of children born in hospitals in Ribeirão Preto in 1978 and 1979 were analyzed. These individuals completed questionnaires, including the questionnaire of the European Community Respiratory Health Survey; underwent spirometry and methacholine challenge test, which measures the bronchial reactivity. For data analysis, asthma was defined by the association of bronchial hyper reactivity with corresponding symptoms: wheezing, tightness in the chest, dyspnea and nocturnal dyspnea. The prevalence of reduced forced expiratory volume in one second (FEV1), i.e. less than 80% of predicted, was 10.9%; the prevalence of bronchial hyper reactivity was 22.2%; and, the prevalence of asthma was 10.4% in this sample of 1922 individuals. Spirometry had a sensitivity of 38% to detect asthma in males and 16% in females with specificities of 94% and 90%, respectively. According to univariate analysis, there was an association between spirometry and asthma diagnosis in males, with prevalence ratio (PR) of 5.31 and 95% confidence interval of 3.60 to 7.83, but there was not association in females, PR was 1.34 (0.87 to 2.07). These results were confirmed by multivariate analysis with PR of 4.20 (2.71 to 6.71) in men and 1.24 (0.79 to 1.93) in women. Kappa agreement between reduced FEV1 and asthma was 0.13 (0.08 - 0.19). Therefore, by using positive methacholine challenge test with symptoms to define asthma, spirometry shows limits, as low sensitivity, poor concordance and differences between genders.

Page generated in 0.0941 seconds