• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 80
  • 17
  • Tagged with
  • 97
  • 56
  • 55
  • 41
  • 41
  • 32
  • 26
  • 18
  • 17
  • 17
  • 16
  • 16
  • 16
  • 15
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Energioptimering av Hemsö fästning med förslag på energieffektivare systemlösningar

Lantz, Conny January 2013 (has links)
The report is a master thesis about energy efficient measures for an underground facility Hemsö fortress.Several proposals are evaluated economically.Statistics of the electricity used and measurements of several heat pumps are analyzed to find energysavings potentials.The results indicate that several units of a dehumidification system are responsible for over 70 % of theyearly electricity cost. The air that is being dehumidified by these units can otherwise cause damage ofculturally important interior designs.The proposal with highest profit suggests an alternative method for dehumidification. The cooler in theair handling units in Hemsö fortress have capacity to dehumidify the air. However complementary fansneed to be installed to circulate humid air towards the air handling units. The solution can be implementedin three different locations within the facility. LCC for one installation shows a profit of 180 000SEK and for three 540 000 SEK, which is equivalent to an annual reduction of electricity consumption by10%. / Rapporten beskriver flera förslag på åtgärder för att på ett ekonomiskt lönsamt sätt minska energianvändningeni Hemsö fästning. Statistik över elanvändningen och mätningar på flera värmepumpar liggersom grund till de föreslagna åtgärderna.Analys av statistisk data visade att flera Muntersavfuktare, med syfte att torka luften, årligen använderöver 70 % av all el som tillförs anläggningen. Torkarna är essentiella för att förhindra fuktskador på kulturelltviktiga interiörer.Den mest lönsamma metoden att minska på elanvändningen visades vara att ersätta flertalet av Muntersavfuktarnamed en annan systemlösning. De redan befintliga ventilationsaggregaten har kapacitetnog att kondensavfukta luften med kylenergi från en värmepump. Dock krävs kompletterande fläktinstallationerför att återföra fuktig luft till ventilationsaggregaten. Besparingsåtgärden kan tillämpas påtre ställen i anläggningen. LCC för en installation pekar på en besparing på 180 000 kr på 20 år och förtre installationer 540 000 kr, vilket motsvarar en årlig sänkning av elanvändningen med 10 % i Hemsöfästning.
32

Värmeförluster i tank : En visualisering och optimering av värmeförluster för inomhusmodul samt omvärldsanalys av värmepumpar / Heat Losses in Accumulator Tank : A Visualization and Optimization of Heat Losses for an Accumulator Tank and External Analysis of Heat Pumps

Pranjic, Daniel January 2022 (has links)
Att koppla en inomhusmodul till en värmepump ger möjlighet att lagra värme, och gör användaren mindre beroende av elpriser och tillgång på bränsle. Ett företag som tillverkar inomhusmoduler och värmepumpar är Enertech AB, som har ett mål att energieffektivisera företagets produkter och minska värmeförluster. För att minska värmeförluster för en specifik inomhusmodul, identifieras och åtgärdas möjliga källor till förluster. Dessa delas upp i olika fall (Fall 1 – Fall 9) som åtgärdas utefter värmeförlusten. Med hjälp av temperaturgivare, effektmätare och programmet EasyView kan värmeförlusterna tas fram. Efter fyra mätningar per fall visas ett resultat som jämförs med grundtillståndet, där produkten står utan extern isolering eller åtgärd. De olika fallen delas upp i grundtillstånd, kundens tillstånd, isolering av sidoanslutningar, övre sladdanslutning, spalter, övre röranslutningar, bakre lucka, solslinga samt kombination av alla åtgärder. Resultatet från undersökningen visar att fallet med kombinerade åtgärder har minst värmeförluster på 135 W. Detta är 18 % mindre än grundtillståndet, alltså 164 W. Efter 25 år sparas 6 400 kWh för kombinerade åtgärder och det sparas 4 000 kWh vid isolering av övre röranslutningar jämfört med grundtillståndet. För enskilda åtgärder har isolering av övre rör och sidoanslutningar minst värmeförluster. En omvärldsanalys genomförs som visar att marknaden för värmepumpar växer 10 % årligen de kommande fem åren. Det finns möjligheter att ersätta gasbaserade värmesystem och miljöpåverkan för värmepumpar beror på källan till elektriciteten.
33

Val av uppvärmningssystem utifrån ett kostnads- och miljöperspektiv

Acuna, Gerardo, Rooth, Patrik January 2012 (has links)
Uppvärmningskostnader för äldre flerbostadshus utgör oftast en tung post i de löpandedriftskostnaderna. Att som fastighetsägare se över vilka alternativ till uppvärmning det finnspå marknaden kan leda till stora besparingar i en värld där energikostnader bara ökar ochökar. Lamellhus från perioden 1941-1960 utgör en stor andel av Sveriges bostadsbestånd ochär i behov av modernisering. I denna rapport studerar vi uppvärmningskällorna fjärrvärme ochgrundvattenvärmepump för en sådan byggnad ur ett kostnads- och miljöperspektiv.Genom att skapa en modell av byggnaden i VIP Energy beräknas behovet av tillförd energiför uppvärmning och tappvatten. Livscykelkostnader för de olika uppvärmningsalternativenberäknas under en 20-års period. Utsläpp som de olika systemen står för beräknas sedan förett år. Resultaten från LCC- och utsläppsberäkningen analyseras i diskussionen. De olikasystemen bedöms utifrån tre synvinklar: kostnader, miljöpåverkan och samhällperspektiv.En grundvattenvärmepump är klart att föredra ur det ekonomiska perspektivet. I miljö- ochsamhällsperspektivet är det dock svårare att definiera det bästa alternativet. Sett utifrån denenskilda byggnadens miljöpåverkan minskar grundvattenvärmepumpen utsläppen, dockskapar den ett ökat behov av primärenergi medan fjärrvärme utnyttjar befintliga lågvärdigarestprodukter som bränsle och producerar värme och el, vilket är positivt för både samhälleoch miljö. / Heating costs for older multi-dwelling buildings are usually a heavy item of operatingexpenditure. As a property owner, reviewing the options for heating available on the marketcan lead to big savings. In this report we study the heating sources district heating andgroundwater heat pump for a multi-dwelling building from a cost and environmentalperspective.A groundwater heat pump is clearly preferable from an economic perspective. However, it isdifficult to define the best option from an environmental and a society perspective. Thegroundwater heat pump reduces the individual building's emissions although it increases theneed for new produced energy on a society perspective.
34

VVS-projekteringsförslag på LSS-bostad

Sedin, Marcus January 2016 (has links)
I Sverige finns det cirka 4,5 miljoner bostäder och den siffran stiger i lika snabb takt med den ökande befolkningen. Riksdagen har beslutat att energianvändningen ska minska i två etapper utifrån EU:s direktiv att uppnå så kallade näranollenergibyggnader.Här beskrivs vilka parametrar som utgör en byggnads energiprestanda och hur man sänker energianvändningen i bostäder genom VVS-projektering. Framförallt hur man kan nå detta utifrån den ekonomiska aspekten. Vilka regler och krav måste följas för att inte påverka människans hälsa.Projektet innefattar teoretiska sammanställningar av VVS komponenter som är grunden till genomförandet. Den tänkta bostaden byggdes upp och simulerades i simuleringsprogrammet IDA ICE för att plocka fram viktig information till VVS-projekteringen.Resultatet visar att en bergvärmepump är en fördelaktig värmekälla ekonomiskt men framförallt energimässigt. Ventilationssystemet klarade att upprätthålla ett gott inomhusklimat utan att bryta mot några föreskrifter.
35

Driftoptimering av lakvatten­­rening : Jämförelse mellan tekniker för uppvärmning av nitrifikationsdammen på Häringetorp avfalls­anläggning

Adolfsson, Beatrice, Johansson Mess, Marja January 2017 (has links)
Biologisk lakvattenrening, med hjälp av mikroorganismer, används på Häringetorp avfallsanläggning för att bland annat reducera mängden kväve i lakvattnet. För att möjliggöra en längre reningsperiod, eftersom mikro­organismernas tillväxt hämmas vid låga temperaturer, vill Tekniska förvaltningen på Växjö kommun studera möjligheten att värma upp nitrifikationsdammen på Häringetorp avfallsanläggning med hjälp av grön energi. Kvantifiering av effektbehov för förlängning av reningsperioden har gjorts utifrån en simuleringsmodell. Studie av tillförd effekt har gjorts under det första året med tillförd effekt. Jämförelse mellan de tekniska lösningarna solfångare, värmepump och biobränslepanna har gjorts gällande aspekterna driftsäkerhet, praktisk genomförbarhet, enkelhet och ekonomi. Utifrån diskussion ges rekommendation att installera en värmepump, vilken utnyttjar intern energi, för att levererar en effekt till nitrifikationsdammen på 100 kW under temperaturstyrda förhållanden. Denna tillförsel av effekt förväntas ge en förlängning av reningsperioden på fyra veckor.
36

Energiåtervinning med frånluftsvärmepump i flerbostadshus : Simulering av ventilationsförluster och potentiell besparing, Spättan 1 / Energy recovery with exhaust air heat pump in apartment buildings : Simulation of ventilation losses and potential savings, Spättan 1

Holmqvist, Patrik, Fasth, Arvid January 2019 (has links)
Energi är ett ständigt aktuellt ämne, där byggnader står för en stor del av energianvändningen i Europa och Sverige. Samtidigt som energieffektiviseringar genomförs måste ett tillräckligt luftflöde bibehållas i byggnaden för att uppnå en komfortabel inomhusmiljö. Detta medför att en stor mängd energi cirkulerar i byggnadens ventilationssystem. Rapporten innehåller en simulering för att fastställa hur stor del denna är, kontra det totala energibehovet för ett flerbostadshus beläget i Kalmar, Sverige. Resultatet visar att ventilationen står för 35 % av det totala värmebehovet. Potentialen för återvinningsbar energi beräknades för att utvärdera hur mycket energi som kan sparas genom att installera en frånluftsvärmepump på ventilationssystemet. Simuleringar visar att vid ett godkänt minimumflöde på 0,35 l/s∙m2, skulle fastigheten kunna vara självförsörjande på värme under sommarmånaderna. Detta innebär att det går att återvinna ca 57 kWh/m2∙år, en reducering av energibehovet med 30 %. Vidare arbete skulle innebära fler mätningar på flöden, temperatur och fuktigheter.
37

Miljökonsekvenserna av Växjö kommuns energikrav på bostäder på Östra Lugnet

Johansson, Martina, Petersson, Johanna January 2013 (has links)
I detta examensarbete studeras miljökonsekvenser av Växjö kommuns ställda energikrav på bostadsområdet Östra Lugnet i Växjö. Dessutom studeras hur väl Växjö kommuns och BBRs (Boverkets byggregler) krav på specifik energianvändning efterlevs. Växjö kommuns krav ställs på både företag och privatpersoner där kravet innefattar anslutning till Växjös fjärrvärmenät. Kommunen ställer också krav på företag gällande specifik energianvändning.   Denna studie uppvisar skillnader, både mellan företag och privatpersoner men även mellan företags olika kvarter, i hur väl ställda energikrav efterlevs. Där lyckas företagen sämst, trots att de haft strängare krav.   Studien visar också att fjärrvärme bidrar till en minskning av koldioxidutsläpp, vilket stöder Växjö kommuns kravställande på fjärrvärmeanslutning.
38

Vitvarueffektivisering med hjälp av värmelagring : Simuleringsstudie kring energiförsörjning av vitvaror med hjälp av värmepump & ackumulatortank

Ladekvist Zetterfeldt, Karl-Johan January 2013 (has links)
The constant need of energy is something that affects us all no matter our current situation. Whether we are driving our car to work, taking the elevator or using the oven to cook dinner we end up relying on energy. Our whole society is continuously striving to achieve a higher grade of efficiency and the process of supplying ourselves with energy is no exception. The importance of appliances in our everyday life cannot be exaggerated and thus the importance of their high efficiency. Efficiency is already a keyword in the appliance industry with labels, stars and numbers helping us choosing the most suitable option for the task ahead. No matter how efficient appliances often use pure electricity as their energy source. This is where the heat pump shines being an excellent way of removing excess heat where it is not needed to somewhere where it is put to good use.    The goal of this study is to research the possibility of supplying a range of household appliances with a single solution built around a heat storage tank, this being a far simpler and cheaper solution then supplying each and every one of them with their own solution. The storage tank will act as a buffer during the peak periods of usage will be supplied with energy by a heat pump.   The system has been modeled with Comsol, a calculation and simulation software, to be able to preserve details as close to reality as possible. Different storage tank sizes combined with different heating values has been tested to determine the optimal combination.   Results show that the system is a plausible solution to the problem and that a compressor using 290W to supply the storage tank with 1000W of heat is enough to handle the peak periods of the appliance usage. The efficiency of the system depends on the heat source and while using the exhaust air from the household is recommended, the study presents two more options. The key to handling the peak periods is the storage tank acting as a buffer then being reheated over time. / Tillgången på energi eller snarare behovet av den är något som genomsyrar hela vår tillvaro. Vare sig vi tar bilen till jobbet, hissen upp till lägenheten eller värmer på maten i ugnen så gör vi oss beroende utav den. Hela vårt samhälle strävar kontinuerligt efter att effektiviseras oavsett om drivkraften är nyfikenhet, tvång eller ökad förtjänst och energitillförsel är inget undantag. Vikten av vitvaror i vår vardag kan knappast överdrivas och därför har också effektiviseringen av dem prioriterats högt. Idag jobbar industrin för fullt med att finslipa tekniken för att pressa energiförbrukningen allt lägre och man har även valt att börja utnyttja värmepumpen som ett sätt att värma apparaturen ännu effektivare. Värmepumpen är ett lysande verktyg för att flytta energi ifrån en plats med överskott till en situation med behov och att utnyttja exempelvis den energi vi annars vädrar ut ur huset till att värma hushållets vitvaror skulle innebära en betydligt effektivare resurshantering.   Studien syftar till att undersöka huruvida det totala energibehovet från ett genomsnittligt hushålls vitvaror gemensamt kan lösas utav en ensam värmelagringslösning. En ackumulatortank skall förses med värmeenergi som sedan bygger en buffert stor nog för en diskmaskin, en tvättmaskin och en torktumlare under vardaglig användning. Energitillförseln kommer att ske med hjälp utav en värmepump. Systemet är dimensionerat med hjälp utav beräkningsprogramvaran Comsol och har tagit hänsyn till variationer i såväl tankstorlek som tillförd värme från värmepumpen. Resultatet visar att lösningen är fullt möjlig och att en kompressoreffekt på ca 290W krävs för att flytta 1000W värme från en valfri källa, förslagsvis frånluften i hushållet, till vitvarorna. Den tänkta lösningen blir olika effektiv beroende på källan till värmen men visar sig vara en energisnålare lösning än konventionell eldrift. Nyckeln i sammanhanget blir ackumulatortanken som ser till att energin finns tillgänglig när den behövs och att den normalt höga effekten som krävs från vitvaror istället fylls på över tid och hanteras momentant genom tankens buffert.
39

Verktyg för att analysera Karlstad Centralsjukhus värme & kylproduktion / A tool for analyzing Karlstad Central Hospital heating & cooling production

Hammar, Martin January 2012 (has links)
Världens energipriser har ökat drastiskt sedan 1970-talet. Detta skapar incitament för investeringar för att sänka sina energikostnader, vilket det satsas på inom industri-, transport- och bebyggelsesektorn. Karlstad Centralsjukhus är inget undantag gällande dessa investeringar och med en lokalyta motsvarande 26 fotbollsplaner med aktivitet dygnen runt förbrukas här stora mängder energi, om inte annat bara för att värma och kyla sjukhuset till ett behagligt klimat. För tillfället sker ombyggnationer över hela sjukhuset för att minska dess energianvändning. Efter ombyggnationer som färdigställdes september 2010 ändrades sjukhusets energiproduktion. Det installerades då sex värmepumpar, två kopplade mot sjukhusets kylsystem för återvinna värme och fyra stycken mot 81 nya borrhål och Klarälven, som rinner förbi sjukhuset. Fjärrvärme används som reserv- och spetskraft när inte värmepumparna klarar leverera hela värmebehovet. Sjukhusets kyla produceras genom de två värmepumparna, kylmaskiner samt frikyla från berget. I projekteringen av anläggningen var värmepumparna dimensionerade att lösa värmeenergibehovet till -4°C resten skulle täckas upp av fjärrvärme. Berget skulle ge möjlighet att säsongslagra energi mellan årstiderna. Drift av anläggningen har dock visat att verkligheten skiljer sig från projekteringen. Värmepumparna har inte kunnat användas fullt ut vintertid då varken berg eller älv har fungerat sig som tänkt. Den driftstrategi som togs fram vid projekteringen stämmer därmed inte utan en ny måste tas fram. Detta examensarbete är ett steg i detta arbete, projektets mål var att i samarbete med Centralsjukhusets driftpersonal ta fram ett verktyg för att kunna analysera sjukhusets drifthistorik. Verktygets målgrupp är sjukhusets driftpersonal så dess utformning måste vara lättförstådd för dessa varför en testperiod gjordes av dessa innan slutgiltig överlämning. Verktyget som togs fram gjordes i Microsoft Exel och det skapar fyra stycken varaktighetsdiagram av drifthistoriken för varje år. Två som visar värme- respektive kyleffekten i kW under ett år och vad som producerat denna effekt. De andra två visar kostnaden per månad i tusen kronor för dessa effekter. Detta gör verktyget genom att bearbeta data som samlas in effekt och temperaturmätare som finns installerade i anläggningen och samlas in genom övervakningsprogrammet Citec och statistikprogrammet WebEss. Genom att jämföra effektdiagrammet för värme och kostnadsdiagrammet går det då att se exempelvis vad värmepumparna producerat och hur mycket denna produktion kostat. Ett ledord i arbetet har varit enkelhet för de senare användarna. Verktyget skulle vara smidigt och snabbt att uppdatera och enkelt att förstå. Vilket även uppnåddes. Efter en veckas testperiod hade driftgruppen inga önskade ändringar varav verktyget lämnades över slutgiltigt. Det överlämnades även fyra rekommendationer till landstinget för att få bättre kontroll på sina energikostnader. / The Worlds energy usage has dramatically increased since the 1970's and as a consequence also the prices for energy. This creates incentives for investments with the purpose to decrease energy costs, which is a development you can see in the industry, transport and building sectors. Karlstad Central Hospital is no exception with a floorspace equivalent of 26 football fields and activity around the clock. Just to heat and cool the hospital to a pleasant climate consumes a large amount of energy. Currently the parts of the hospital is being rebuilt to reduce its energy consumption. In September 2010 the hospital's energy production changed . When six heatpumps were installed, two linked to hospital cooling system to recover heat and four to geothermal heat by 81 boreholes and the river Klarälven, which runs past the hospital. Long-distance heating is used for peak loads and in reserve when the heat pumps cannot supply all heating needs. The hospital's cooling is produced by the two heat pumps, three cooling machines and free cooling from the geothermal connection. When designing the new energy production it was meant that the heat pumps should produce the heat required to -4 ° C, the rest would be covered by long-distance heating. The boreholes would make possible to storage energy between seasons. But operation of the plant has shown that reality differs from the theory. The heatpumps have not been fully utilized during the winter when neither the geothermal or the river behaved as intended. The operating strategy that was developed during project planning valid and therefore needs to be revised. This thesis is a step in that effort. The project's objectives was to produce a tool to analyze the hospital's operating history in cooperation with the Central Hospital's engineering staff. The tools users is meant to be the same staff so its design must be easily understood for those. A trialperiod took place therefore before the final handover. The tool was developed in Microsoft Excel and it creates four graphs showing the operational history of each year. Two of them are showing the heat- or cold-output in kilowatts for a year and what produces this output. The other two shows the cost in thousand swedish crowns to produce these effects. The tool calculates thus by collecting data from power and temperatur gauges installed in the hospitol and is collected by the monitoring program Citec och statistics program WebEss. By comparing the power and cost graph for heat it can be seen for example what heat pumps produced and how much the production cost. A key word in the development of the tool has been simplicity for the users. The tool should be easy and fast to update and simple to understand, which was achieved. After a week's trial had been running the staff had no wanted changes so the tool was handed over.
40

Åtgärdsplan för energieffektiviseringav ett flerbostadshus från 1940-talet : En fallstudie av Vindelgatan 15 i Ludvika / Improving energy efficiency for an apartment buildingfrom the 1940s : A case study of Vindelgatan 15 in Ludvika

Djärv, Oskar January 2015 (has links)
A housing association in Ludvika owns an apartment building built 1942 with a heating system based on district heating. The housing association is interested in reducing their annual energy cost, which corresponds to reducing their energy consumption. The yearly energy consumption for the building at the moment is about 40 % above the average for Swedish apartment buildings. This report investigates the possibilities of reducing the total energy consumption for the building, in a profitable way, and at the same time meeting the governmental targets for 2050 and the maximum specific energy demand for new buildings presented by the building regulation. The method used in this report was to conduct simulations of models of the building where proposals in terms of reducing the use of heat were evaluated. The proposals were related to the ventilation system, the building envelope, and solar power installations. The simulations returned results of many proposals that could reduce the energy consumption, but just a few turned out to be financially viable. Installing an exhaust air heat pump in combination with solar panels for heat supply and solar cells for electricity was found to be the most viable solution. A combination of these three proposals was calculated to reduce the yearly heat consumption with 188 MWh and the total energy consumption by 50 %, which meets the 2050 target. The specific energy consumption of the building per square meter of heated area is 97 kWh, which means that the maximum specific energy demand of 110 kWh is met.

Page generated in 0.0366 seconds