• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 18
  • Tagged with
  • 49
  • 49
  • 49
  • 49
  • 25
  • 13
  • 12
  • 12
  • 10
  • 10
  • 10
  • 9
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

A method for traceable protein quantification using isotope dilution ICP-MS and its application on the tau protein

Lemke, Nora 19 August 2022 (has links)
In dieser Arbeit wurde ein Verfahren zur rückführbaren Proteinquantifizierung unter Verwendung von Schwefelisotopenverdünnung mit induktiv gekoppelter Plasmamassenspektrometrie (ID-ICP-MS) entwickelt. Die Methode dient zur zuverlässigen Quantifizierung laborinterner Proteinstandards. Sie eignet sich nur zur Analyse reiner Proteine, deren Stöchiometrie bekannt ist, da die Proteinkonzentration aus dem Schwefelgehalt bestimmt wird. Nicht proteingebundener Schwefel wird durch Membranfiltration von der Proteinfraktion abgetrennt und mit ID-ICP-MS quantifiziert. Der Gesamtschwefelgehalt in der Probe wird ebenfalls mittels ID-ICP-MS quantifiziert und um die Menge an ungebundenem Schwefel korrigiert. Die Optimierung der Probenvorbereitung zeigte, dass ein Aufschluss die Unsicherheit des Ergebnisses verbessert. Für die Methodenentwicklung wurden ein zertifiziertes Rinderserumalbumin-Referenzmaterial (BSA), sowie ein kommerzielles Avidin verwendet. Die Bestimmung der Proteinmassenfraktionen und Unsicherheitsbudgets erfolgte nach Korrektur für den ungebundenen Schwefel (0,4 % für BSA, 30 % für Avidin). Die Methode wurde auf das Tau-Protein angewendet, das ein Biomarker für die sogenannten „Tauopathien“ ist – eine Gruppe neurodegenerativer Krankheiten, die die Alzheimer-Krankheit und die frontotemporale Demenz einschließen. Durch Verwendung eines isotopenangereicherten Spikes, der an das SI-System angebunden ist, wurde die metrologische Rückführbarkeit für den Massenanteil des Tau-Proteins erreicht. Dieser Tau-Standard wurde zur absoluten Quantifizierung toxischer transgener Tau-Spezies in der löslichen Hirnfraktion transgener Mäuse verwendet. Die entwickelte Methode ist für die rückführbare Quantifizierung von Proteinen zur Verwendung als Standards in der biologischen und medizinischen Forschung anwendbar. Sie zeigte eine ähnliche Präzision wie etablierte Verfahren, erforderte jedoch weniger Probenvorbereitung und keine spezies-spezifischen Standards. / In this work, a method for traceable protein quantification using sulphur isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) was developed. The method is intended for the reliable quantification of in-house protein standards. It is only suited for pure protein formulations for proteins of known stoichiometry because the protein concentration is determined from the sulphur content. Non-protein bound sulphur is separated from the protein fraction by membrane filtration and is quantified by ID-ICP-MS. The total sulphur content in the sample is as well quantified by ID-ICP-MS and corrected for the amount of non-protein bound sulphur. Optimisation of the sample preparation showed that digestion improves the uncertainty of the result. For method development, a certified reference material bovine serum albumin (BSA) and a commercial avidin were used. The protein mass fractions with full uncertainty budgets were determined after correction for unbound sulphur. The developed procedure was applied to the tau protein, which is a biomarker fort he so-called „tauopathies“ – a group of neurodegenerative diseases including Alzheimer’s disease and Frontotemporal dementia. By employing an isotopically enriched spike, which is linked to the SI system, full metrological traceability was achieved for the tau mass fraction. The mass fraction of (0.328 ± 0.036) g kg-1 for tau was determined by ID-ICP-MS and confirmed by amino acid analysis. This tau standard was used for the absolute quantification of toxic transgenic tau species in the soluble brain fraction of transgenic mice. The developed method is applicable for the traceable quantification of proteins for use as standards in biological and medical research. The precision of the method was similar to established absolute protein quantification procedures while requiring less sample preparation and no species-specific standards.
42

Molecular Control of Extracellular Matrix-inspired Biohybrid Hydrogels

Song, Geonho 03 April 2023 (has links)
Das Verständnis natürlicher biologischen Materialien für die Entwicklung neuer biomimetischer Materialien ist von großem Interesse in der Chemie und den Materialwissenschaften. In vielen komplexen biomolekularen Materialien ist die Etablierung der Struktur-Funktionsbeziehungen von Proteinbausteine notwendig, um die Eigenschaften der daraus aufgebauten weichen, biologischen Materialien zu verstehen, wie z. B. die extrazelluläre Matrix. Inspiriert durch bekannte Faltungsmotive von ECM-Proteinen, wurden vereinfachte Modellpeptide entwickelt, um deren Funktion zu untersuchen oder diese als biomimetische Bausteine für synthetische Biomaterialien zu verwenden. Ziel dieser Arbeit war die Synthese von hybriden Hydrogelen, die aus einem synthetischen Polymer und ECM-inspirierten Modellpeptiden zusammengesetzt sind. Insbesondere Kollagen-mimetische Peptide und Coiled-Coil-formende Peptide wurden benutzt, um das biokompatible und hydrophile Polymer Polyethyleneglykol zu vernetzen. Dabei wurde von der Fähigkeit dieser Peptide zur dynamischen Selbstassemblierung Gebrauch gemacht. Unter Verwendung von Kollagen-mimetischen Peptiden mit langsamer Dissoziationskinetik wurden Hydrogele synthetisiert, die weichen, glasartigen Materialien mit einem gestauchten exponentiellen Relaxationsverhalten entsprechen und auch einen Alterungsprozess zeigen. Darüber hinaus wurde gezeigt, dass Netzwerkkonnektivität ein bis dato selten gebrauchter Designparameter ist, um die rheologischen Eigenschaften von Hydrogelen nach Wunsch zu kontrollieren. Die Kombination molekular einstellbarer Vernetzer mit einem Fluoreszenz-Reportersystem, welches deren Zustand auslesen kann, kann detaillierte Einblicke in das Reaktionsvermögen solcher Netzwerke auf mechanische Stimuli ermöglichen. Das Verständnis molekularer Prozesse erlaubt langfristig die Synthese von ECM-inspirierten Biomaterialien, deren Eigenschaften nach Wunsch einstellbar sind und die selbst ihren mikroskopischen und mesoskopischen Zustand anzeigen. / Understanding natural biological materials for the development of novel biomimetic materials has drawn enormous attention from the areas of chemistry and material science. In many complex biomolecular materials, establishing molecular structure-function relationships of proteins forms the basis for understanding the emerging properties of various biological soft materials, such as the extracellular matrix (ECM). Inspired by common association motifs of ECM proteins, simplified model peptides have been developed for functional studies and as biomimetic building blocks for synthetic biomaterials. The aim of this thesis was to utilize ECM-inspired and molecularly controlled model peptides for the synthesis of peptide-polymer hybrid hydrogels. Specifically, collagen-mimetic peptides (CMPs) and coiled coil (CC)-forming peptides were utilized to crosslink the biocompatible and hydrophilic polymer poly(ethylene glycol) (PEG), making use of the ability of these peptides to dynamically self-assemble. Employing CMPs with slow dissociation kinetics, hydrogels have been synthesized that resemble soft glassy materials with compressed exponential relaxation and aging. Furthermore, network connectivity has been shown to be an underutilized design parameter for tuning the rheological properties of hydrogels. Combining molecularly controlled crosslinks with a fluorescence reporter system that allows to read out crosslink status will ultimately allow for more detailed insights into the response of such networks to mechanical perturbation and thus aid the synthesis of ECM-inspired biomaterials with tunable and self-reporting properties.
43

Sensory molecularly imprinted polymer (MIP) coatings for nanoparticle- and fiber optic-based assays

Wagner, Sabine 22 March 2019 (has links)
Für den Nachweis dieser Schadstoffe in niedrigen Konzentrationsbereichen sind schnelle und empfindliche Analysemethoden erforderlich. Molekular geprägte Polymere (MIPs) wurden als synthetische Materialien entwickelt, um die molekulare Erkennung von natürlichen Rezeptoren nachzuahmen, aufgrund ihrer Fähigkeit, selektiv eine Vielzahl von Analyten zu erkennen, ihre Stabilität und ihrer einfachen Herstellung. Sie sind zunehmend in der chemischen Sensorik als Rezeptormaterial für den Nachweis bestimmter Analyten bei niedrigen Konzentrationen zu finden, insbesondere in Kombination mit Fluoreszenz aufgrund dessen hoher Empfindlichkeit. Ziel dieser Arbeit war die Entwicklung von optischen Sensormaterialien unter Verwendung von MIPs als Erkennungselemente im Zusammenhang mit Fluoreszenz zum sensitiven Nachweis von Herbiziden und Antibiotika in Wasser- und Lebensmittelproben and deren Kombination mit verschiedenen Vorrichtungsformaten für die zukünftige Detektion einer breiten Palette von wichtigen Analyten. / For the detection of these contaminants in low concentration ranges fast and sensitive analytical tools are required. Molecularly imprinted polymers (MIPs) have been used as synthetic materials mimicking molecular recognition by natural receptors due to their ability to recognize selectively a wide range of analytes, their stability and ease of synthesis. They have gained more and more attention in chemical sensing as receptor material for the detection of suitable groups of analytes at low concentrations especially in combination with fluorescence due to the latter’s high sensitivity. This work aimed the development of optical sensor materials using MIPs as recognition elements connected with fluorescence for the sensitive detection of herbicides and antibiotics in water and food samples and their combination with various device formats for the future detection of a wide range of analytes.
44

Polymorphism of Organic Molecular Crystals

Nguyen, Thi Yen 20 February 2018 (has links)
Die Kristallisation ist ein wichtiger Teilprozess bei der industriellen Herstellung vieler Materialien und Medikamente. Es ist jedoch ein vielschichtiger, physikalischer Vorgang, der noch nicht vollständig aufgeklärt ist. Der Schwerpunkt dieser Arbeit liegt auf der Kristallisation von organischen, polymorphen Verbindungen aus unterschiedlichen Lösungsmitteln. Die Kristallisationsstudien wurden in einem akustischen Levitator mit Klimakammer, der den Einfluss von Temperatur, Feuchtigkeit und festen Oberflächen steuert, durchgeführt. Verschiedene analytische in-situ-Methoden und deren Kopplung kamen für die Analyse der Kristallisationsabläufe zum Einsatz. Als Unterstützung für die Interpretation der beobachteten Phänomene wurden unter äquivalenten Bedingungen Moleküldynamik-Simulationen vorgenommen. Die Kristallisation der Modellverbindungen zeigte verschiedene spezifische Kristallisationspfade, die nicht dem klassischen Kristallisationsmodell entsprachen. Zunächst verdampfte das Lösungsmittel, was mit einer Konzentrationszunahme der Lösung und der Ausbildung von charakteristischen amorphen Phasen (Polyamorphismus) einherging, und schließlich trat die Kristallisation ein. Durch die oberflächenfreie Kristallisation wurde ausschließlich nur ein Polymorph ein- und derselben Verbindung als Kristallisationsprodukt isoliert. Die gezielte Wahl der Ausgangskonzentration und eines Lösungsmittels ermöglichte die Steuerung des Kristallisationsverlaufs hin zu einer gewünschten Kristallstruktur des untersuchten Materials. Die Ergebnisse dieser Arbeit unterstützen das Verständnis über den komplexen Ablauf des Kristallisationsvorgangs, gleichzeitig zeigen sie weitere Ansätze auf, die Kristallisation zu untersuchen. Die neuen Erkenntnisse sind hilfreich bei der Optimierung der Herstellungsprozesse verschiedener Materialien. / Crystallization is a complex process, which is used in different processes in the industrial production of various materials. The limited understanding about its fundamental mechanisms challenges the control of crystallization and influences the quality of the materials. The research of this work concentrates on the crystallization studies of organic model systems (active pharmaceutical ingredients) from different organic solvents in an acoustic levitator. This specific sample environment regulates the influence that solid surfaces, temperature, and humidity have on the crystallization process. The investigations were performed with in situ analytical techniques and theoretical simulations to gain a comprehensive insight into processes, occurring intermediates, and required reaction conditions. The results show that the model systems follow specific crystallization pathways different than those predicted by the classical nucleation theory. The crystallization proceeded via the evaporation of the solvent and the formation of characteristic amorphous phases (polyamorphism) into one crystalline structure of the compound. The targeted choice of the solvent and the concentration enabled the guidance of the pathways, therefore, resulting in the isolation of one desired crystalline structure. The findings are of great interest and they help explain the crystallization mechanisms on a molecular level, which is a fundamental contribution for the optimization of manufacturing processes.
45

Laser-Induced Breakdown Spectroscopy for the Exploration of Mars: Analysis of Molecular Emissions and Spatial Characterization of the Plasma

Vogt, David Sebastian 17 January 2020 (has links)
Die Arbeit beschäftigt sich mit laser-induzierter Plasmaspektroskopie (LIBS) im Kontext der robotischen Mars-Erkundung. Bei LIBS wird Plasma analysiert, das durch Ablation von Probenmaterial gebildet wird. Die Methode wird seit 2012 von dem Instrument ChemCam des Mars-Rovers Curiosity eingesetzt, um das Gestein und den Boden der Marsoberfläche zu untersuchen. Sie wird auch in der NASA-Mission Mars 2020 und in der chinesischen Mission HX-1 eingesetzt werden, welche im Jahr 2020 zum Mars starten sollen. Zwei Studien dieser Arbeit betrachten Emissionen von Molekülen, die sich im Plasma bilden. Diese können zur Detektion von Chlor und Fluor eingesetzt werden, die von geologischem Interesse für Mars sind. Emissionen von MgCl und CaCl werden in simulierten Marsbedingungen für die Bestimmung der Chlorkonzentration untersucht. Nur das CaCl-Signal wird als stark genug befunden. Dieses ist am stärksten bei vergleichsweise geringen Chlorkonzentrationen, was durch einen Nichtgleichgewichtszustand des Plasmas erklärt werden kann. In der zweiten Studie werden die Emissionen von CaCl und CaF verglichen. Beide können mit demselben Modell in Abhängigkeit der Konzentrationen der Reaktionspartner beschrieben werden. Allerdings werden auch starke Matrixeffekte beobachtet, die die Emissionen beeinträchtigen können. Im letzten Teil der Arbeit wird der Plasma-Imaging-Aufbau beschrieben, der aufgebaut wurde. Der Aufbau ermöglicht räumlich aufgelöste Messungen der Emissionsspektren. Es werden erste Ergebnisse vorgestellt, die mit diesem Aufbau erzielt wurden. Diese zeigen, dass CaCl und CaF nur im Plasmazentrum emittieren, was mit einer Verdünnung und Ausbildung eines Niedertemperaturbereichs im Plasmazentrum erklärt werden kann. Atomare Emissionen von Wasserstoff, Kohlenstoff und Sauerstoff sind dagegen intensiver an der Plasmafront und zeigen Verwirbelungen auf, was auf komplexe Temperaturverteilungen und auf einen starken Einfluss von Strömungen im Plasma hinweist. / In this thesis, laser-induced breakdown spectroscopy (LIBS) is investigated in the context of the robotic exploration of Mars. In LIBS, the plasma formed by laser-ablated sample material is analyzed spectroscopically. Since 2012, it is employed by the ChemCam instrument on board the Mars rover Curiosity to analyze rocks and soil on the Martian surface. The technique will also be used in NASA's Mars 2020 mission and in the Chinese HX-1 mission, which are both scheduled to launch to Mars in 2020. The first two studies are concerned with emissions of molecules that form in the laser-induced plasma. These can be used to detect chlorine and fluorine, which are of geological interest for Mars. In the first study, MgCl and CaCl emissions are investigated for the detection and quantification of chlorine in Martian atmospheric conditions. Only the CaCl signal is found to be intense enough for this purpose. The CaCl signal is found to be skewed towards low chlorine concentrations, which is explained by a non-equilibrium model of the laser-induced plasma. In the second study, the emissions of CaCl and CaF are compared. The same model is used to describe the dependence of both signals on the respective reactant concentrations. Strong matrix effects are observed that affect the observed intensities. In the final part of the thesis the plasma imaging setup that was developed in the context of this thesis is presented. It enables spatially resolved measurements of the plasma emission spectra. First results show that CaCl and CaF emissions are confined close to the plasma center, likely because rarefaction leads to a low-temperature center in which molecules can form. Atomic emissions of hydrogen, carbon, and oxygen are more stable at the plasma front and show signs of vorticity, indicating a complex temperature distribution and a strong influence of flows within the plasma.
46

Development and comparison of analytical methods for the determination of PFASs as sum parameters in environmental samples using HR-CS-GFMAS

Simon, Michael Fabian 28 February 2024 (has links)
Im ersten Teil wurde Probenvorbereitungs-Methoden und instrumentelle Methoden zur Organofluor-Bestimmung verglichen, um Vor- und Nachteile bei der Summenparameter-Analytik von per- und polyfluorierten Alkylverbindungen (PFAS) zu identifizieren. Daher wurden Oberflächenwasserproben aus der Spree in Berlin und Industrieabwasserproben mit zwei PFAS-Summenparametern analysiert – dem extrahierbaren (EOF) und dem adsorbierbaren organisch gebundenen Fluor (AOF). Beide PFAS-Summenparameter wurden mit zwei fluorsensitiven Detektionssystemen analysiert – Hochauflösender Kontinuumstrahler-Graphitofen Molekülabsorptionsspektrometrie (HR-CS-GFMAS) und combustion Ionenchromatographie (CIC). HR-CS-GFMAS erwies sich im Vergleich zu CIC als der empfindlichere und schnellere Ansatz mit höherer Präzision. Im zweiten Teil wurde eine neue Methode zur PFAS-Summenparameteranalyse und EOF-Bestimmung in Bodenproben auf Basis von HR-CS-GFMAS entwickelt und optimiert. EOF-Massenanteile wurden bei mehrfacher Extraktion und Nutzung der Festphasenextraktion (SPE) zur Entfernung anorganischen Fluors untersucht. Bei einem Vergleich der optimierten Methode mit und ohne SPE zeigte sich eine drastische Diskriminierung von Organofluor-Verbindungen mittels SPE. Im dritten Teil wurden Organofluor-Massenbilanzen in aquatischen Systemen anhand von Oberflächenwasser- und Schwebstoffproben (SPM) untersucht. SPM-Proben wurden mit vier komplementären Analysemethoden analysiert – target und non-target, direct total oxidizable precursor assay (dTOPA) und EOF. Daher wurden drei Organofluor-Massenbilanzansätze für die räumlich und zeitaufgelöste SPM-Probenanalyse verwendet: (I) Identifizierung von oxidierbaren PFAS-Vorläufer, (II) Identifizierung des Anteils der identifizierten und nicht identifiziertes EOF und (III) PFAS-target, PFAS dTOPA, non-target-Screening und EOF-Analyse, um das nicht identifizierte EOF aus Ansatz (II) weiter zu entschlüsseln. / In the first part, a comparison of sample preparation and instrumental methods for organofluorine determination was used to identify advantages and disadvantages in sum parameter analysis of per- and polyfluoroalkyl substances (PFASs). Therefore, surface water samples from the Spree River in Berlin, Germany and industrial effluent samples were analyzed using two PFAS sum parameters – the extractable (EOF) and adsorbable organically bound fluorine (AOF). Both PFAS sum parameters were analyzed using two fluorine sensitive detection systems – high-resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) and combustion ion chromatography (CIC). HR-CS-GFMAS turned out to be the more sensitive and faster approach accompanied with higher precision compared to CIC. In the second part, a new method for PFAS sum parameter analysis and EOF determination in soil samples based on HR-CS-GFMAS was developed and optimized. EOF mass fractions were investigated upon multiple extraction and utilization of solid phase extraction (SPE) for inorganic fluorine removal. In a comparison of the optimized method with and without SPE, a highly biased discrimination of organofluorines using SPE was shown. In the third part, organofluorine mass balances were investigated in aquatic systems using surface water and suspended particulate matter (SPM) samples. SPM samples were analyzed using 4 complementary analytical methods – target and non-target HRMS, direct total oxidizable precursor assay (dTOPA) and EOF. Therefore, 3 organofluorine mass balance approaches were used for SPM sample analysis in spatial and time resolved manner: (I) Identification of oxidizable PFAS precursors, (II) Identification of the proportion of identified and unidentified EOF and (III) PFAS target, PFAS dTOPA, non-target screening and EOF analysis to further unravel the unidentified EOF from approach (II).
47

Development and Application of IDMS Based Procedure for total Sulphur in Copper Metals and Its Alloys

Phukphatthanachai, Pranee 05 April 2019 (has links)
Bei der Schwefelquantifizierung in Kupfer und anderen reinen Metallen zeigte sich in der Vergangenheit eine mangelnde SI-Rückführung und zusätzlich inkonsistente Ergebnisse, wenn verschiedene Methoden verglichen wurden. Um diesen Mangel zu beheben ist ein Referenzverfahren erforderlich, welches SI-rückführbare Werte mit einem zuverlässigen Unsicherheitsbudget ermöglicht. In dieser Studie wurde ein entsprechendes Referenzverfahren zur Quantifizierung von Gesamtschwefel in Kupfer basierend auf der induktiv gekoppelten Plasma-Massenspektrometrie und der Isotopenverdünnungsanalyse (ICP-IDMS) entwickelt. Um diese Probleme zu lösen wurde mit Hilfe der Ionenaustauschchromatographie ein Schwefel-Matrix-Trennverfahren entwickelt. Dieses Trennverfahren wurde mit ICP-IDMS kombiniert, um Schwierigkeiten mit der Kalibrierung zu lösen und fehlende metrologische Konzepte einzuführen. So wurden die in diesem Projekt erzielten IDMS-Messwerte für die Kalibrierung von GDMS und LA-ICP-MS verwendet, beides Verfahren die im industriellen Einsatz üblich sind. Dadurch konnten mit beiden Routineverfahren zuverlässige Ergebnisse erzeilt warden, die zudem auf SI rückführbar sind. Darüber hinaus wurde ein auf der LA-ICP-IDMS basierendes Verfahren entwickelt, um den Probenvorbereitungsschritt von ICP-IDMS mit Schwefel-Matrix-Trennung zu reduzieren. Die Vorteile dieser Methode sind ein geringerer Arbeits- und Zeitaufwand, die SI- Rückführung der Messergebnisse und eine für LA-ICP-MS vergleichsweise hohe Genauigkeit. Die Schlüsselrolle hierbei spielte der innovative Einsatz von Polyethylenfritten als Trägermaterial der aufgelösten Probe. Dadurch war die Quantifizierung von Schwefel in Kupferproben mittels LA-ICP-IDMS möglich. Die wesentlichen Parameter wie Absorptionseffizienz der Fritten und Matrixeffekt wurden untersucht. Das entwickelte Verfahren konnte mit Hilfe der ICP-IDMS vollständig validiert werden. / Sulphur quantification in copper and other pure metals in the past revealed a lack of SI-traceability and also showed inconsistent results, when different methods are compared. Therefore, a reference procedure is required to enable SI-traceable measurement results accompanied by a sound uncertainty budget. In this study, such a procedure was developed for the quantification of total sulphur in copper using inductively coupled plasma-isotope dilution mass spectrometry (ICP-IDMS). For solving these problems ion exchange chromatography was applied, and a sulphur-matrix separation procedure was developed. This procedure was combined with ICP-IDMS to solve difficulties with the calibration and to realize metrological concepts. An application of the IDMS procedure was realized by using the measurement results of specific copper samples values for calibrating glow discharge mass spectrometry (GDMS) and laser ablation ICP-MS (LA-ICP-MS). Both techniques are considered routine techniques. Thus, they could provide reliable results which are traceable to the SI. Additionally, a procedure based on LA-ICP-IDMS was developed to significantly reduce the sample preparation step of ICP-IDMS with sulphur-matrix separation. This procedure is less laborious and the measurement results are still SI traceable and offer a comparatively high accuracy for LA-ICP-MS. Key for this development was the innovative application of polyethylene frits as support material for the dissolved sample. Thus, the quantification of sulphur in copper samples by LA-ICP-IDMS could be realized. The essential parameters are investigated such as the absorption efficiency of the frit and matrix effects. The developed procedure was fully validated by means of the ICP-IDMS results.
48

Isolated Graphene Edge Nanoelectrodes: Fabrication, Selective Functionalization, and Electrochemical Sensing

Yadav, Anur 03 August 2021 (has links)
Diese Arbeit präsentiert eine einfache eine einfache, auf Photolithographie basierende Methode zur Darstellung einer isolierten Graphenkante (oder GrEdge) einer Monolage als Nanoelektrode auf einem isolierenden Substrat vorgestellt. Trotz ihrer Millimeter-Länge verhält sich die nur einen Nanometer breite GrEdge-Elektrode wie ein Nanodraht mit einem hohen Seitenverhältnis von 1000000 zu 1. Des Weiteren wird der Einsatz von elektrochemischer Modifikation (ECM) demonstriert, um die GrEdge selektiv mit Metall-Nanopartikeln und organischen Schichten nicht-kovalente oder kovalente zu funktionalisieren, wodurch die Chemie der Kante verändert werden kann. Durch die Anbringung von Metall-Nanopartikeln kann zusätzlich oberflächenverstärkte Raman-Spektroskopie (SERS) genutzt werden, um die chemische Beschaffenheit sowohl der unberührten als auch der funktionalisierten GrEdge zu charakterisieren. Die GrEdge weist sehr hohe Mass-entransportraten auf, was charakteristisch für Nanoelektroden ist. Dementsprechend wird die voltammetrische Antwort von der Kinetik des heterogenen Elektrontransfers (HET) diktiert. An der GrEdge-Elektrode werden hohe HET-Raten beobachtet: mindestens 14 cm/s für Außensphäre sonde Ferrocenmethanol (FcMeOH) mit einem quasi-Nernst'schen Verhalten und 0,06 cm/s oder höher für innere Sphäre sonde Ferricyanide ([Fe(CN)6]3-) mit einer kinetisch kontrollierten Reaktion. Nach der selektiven Modifikation der Kante mit Goldnanopartikeln erweist sich der HET als reversibel, mit einer massentransportbegrenztes Nernst‘sches Verhalten aufweisen für beide Redoxmoleküle. Darüber hinaus ermöglicht die schnelle HET-Kinetik die Detektion der reduzierten Form von Nicotinamid-Adenin-Dinukleotid (NADH) und Flavin-Adenin-Dinukleotid (FAD) mit niedrigen Ansatzpotentialen und hinunter bis zu niedrigen mikromolaren Konzentrationen. Entsprechend verbessert die vorliegende Arbeit das Verständnis der Kante von Graphen und deren Chemie. / This thesis presents a simple photolithography-based method to realize the isolated monolayer graphene edge (or GrEdge) nanoelectrode on an insulating substrate. The millimeter-long and a nanometer-wide GrEdge is found to behave like a nanowire with a high aspect ratio of 1000000-to-1. Further, the use of electrochemical modification (ECM) is demonstrated to selectively functionalize the GrEdge with metal nanoparticles and organic moieties in a non-covalent/ covalent manner to tune the chemistry of the edge. The attachment of metal nanoparticles was used to exploit surface-enhanced Raman scattering (SERS) to characterize the chemistry of both the pristine and the functionalized GrEdge. The GrEdge electrodes were found to exhibit very high mass transport rates, characteristic of nanoelectrodes. Accordingly, the voltammetric response is found to be dictated by the kinetics of heterogeneous electron transfer (HET), attributed to the nanoscale geometry and a unique diffusional profile at such electrodes. At the GrEdge electrode, high HET rates are observed: at least 14 cm/s for outer-sphere probe, ferrocenemethanol (FcMeOH) with a quasi-Nernstian behavior; and 0.06 cm/s or higher for inner-sphere probe, ferricyanide ([Fe(CN)6]3-) with a kinetically controlled response. Upon selective modification of the edge with gold nanoparticles, the HET is found to be reversible, with a mass-transport-limited Nernstian response for both probes. Furthermore, the fast HET kinetics enables the sensing of the reduced form of nicotinamide adenine dinucleotide (NADH) and flavin adenine dinucleotide (FAD) with low onset potentials and down to low micromolar concentrations. Hence, this thesis improves the understanding of the edges of graphene and their chemistry. It also realizes isolated GrEdge as a new class of nanoelectrode which forms an important basis within the fields of fundamental electrochemistry and analytical sciences.
49

The degree of phosphorus saturation of agricultural soils in Brazil and Germany: New approaches for risk assessment of diffuse phosphorus losses and soil phosphorus management

Fischer, Peter 30 November 2018 (has links)
Diffuse Phosphor (P)-Austräge aus der Landwirtschaft tragen zur Gewässereutrophierung bei. Der Phosphorsättigungsgrad (DPS) ist ein etablierter Parameter, um das P-Austragsrisiko aus Böden zu erfassen. Ein bodentypunabhängiger Ansatz, der die Abschätzung des DPS durch eine einfache Standardmethode wasserlöslichen P (WSP) ermöglicht (WSP-DPS-Ansatz), wurde an europäischen Böden entwickelt. In der Dissertation wurde dieser Ansatz erstmalig: i) an tropischen Böden getestet und ii) dazu verwendet P-Austragsrisiken von Boden-P-Monitoringdaten und von landwirtschaftlichen Institutionen empfohlenen P-Gehalten abzuleiten. Neben dem DPS wurde der Einfluss der in Brasilien gängigen anorganischen Oberflächendüngung auf das Austragsrisiko mittels Laboranalysen und Feldstudien erfasst. Die Bodentypunabhängigkeit des WSP-DPS-Ansatzes wurde für Böden Brasiliens bestätigt. Infrarotspektroskopische Analysen lieferten eine Erklärung für relativ niedrige gelöste P-Konzentrationen im Oberflächenabfluss von Oxisols. Pedotransferfunktionen zwischen WSP und Methoden, die in Brasilien und Deutschland zur Abschätzung pflanzenverfügbaren P verwendet werden, ermöglichten die Berechnung von DPS-Werten aus Monitoringdaten. Erste DPS-Karten zeigten relative geringe Austragsrisiken für das Untersuchungsgebiet in Brasilien und hohe Risiken für Deutschland, die teilweise durch unterschiedliche empfohlene Boden-P-Gehalte erklärbar waren. Um mit einer einfachen und kosteneffizienten Methode sowohl die landwirtschaftliche Produktion als auch den Gewässerschutz zu berücksichtigen, wurden die Wasser- und CaCl2-Methode zur Abschätzung von pflanzenverfügbarem P mit dem WSP-DPS-Ansatz kombiniert. Dieser Ansatz könnte helfen die Herausforderungen zu lösen mit denen die Menschheit in den nächsten Jahrzehnten bezüglich P in der Landwirtschaft konfrontiert sein wird: Einer effizienten Nutzung der limitierten Ressource P und dem Schutz der Gewässer vor diffusen P-Einträgen. / Diffuse phosphorus (P) losses from agriculture contribute to the eutrophication of surface waters. The degree of P saturation (DPS) is an established parameter for assessing the risk of P loss from agricultural soils. A soil type-independent approach for estimating the DPS by a simple standard method of water-soluble phosphorus (WSP; the WSP-DPS approach) was developed on European soils. In the thesis, the WSP-DPS approach was for the first time: i) tested on tropical soils and ii) used to derive P loss risks from soil P monitoring data and from recommended soil P levels by agricultural institutions. In addition to DPS, laboratory analyses and field studies were combined to assess the risk of P loss associated with the superficial application of inorganic fertilizer, which is commonly used in Brazil. The soil type-independency of the WSP-DPS approach was confirmed for soils of Brazil. Infrared spectroscopic analyses provided an explanation for the relatively low dissolved P concentrations in the surface runoff of Oxisols. Pedotransfer functions were determined between WSP and methods used to estimate plant-available P in Brazil and Germany and allowed for the transformation of soil P monitoring data into DPS values. The first DPS maps revealed relatively low P loss risks for the investigation area in Brazil and high risks for Germany. This difference was partly explainable by the recommended soil P levels in the two countries. To consider both agricultural production and the protection of surface waters in soil P management with a simple and cost-effective method, the soil test methods of using water and CaCl2 to estimate plant-available P and the WSP-DPS approach were combined. This approach could help to solve the challenges humanity faces regarding P in agriculture in the coming decades: An efficient use of the limited resource P and the protection of surface waters from diffuse P losses.

Page generated in 0.4495 seconds