• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • 1
  • 1
  • Tagged with
  • 51
  • 35
  • 14
  • 13
  • 13
  • 13
  • 12
  • 12
  • 12
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

[en] DEVELOPMENT OF ELECTRO-ANALYTICAL METHODS USING ELECTROCHEMICAL CARBON-BASED SENSORS FOR DETERMINATION OF TRIFLOXYSTROBIN, GENTAMICIN AND LAPACHOL / [pt] DESENVOLVIMENTO DE MÉTODOS ELETROANALÍTICOS UTILIZANDO SENSORES ELETROQUÍMICOS BASEADOS NO CARBONO PARA DETERMINAÇÃO DE TRIFLOXISTROBINA, GENTAMICINA E LAPACHOL

JOSEANY DE MORAES SANTOS ALMEIDA 20 December 2018 (has links)
[pt] O presente trabalho teve como objetivo o desenvolvimento de métodos eletroanalíticos empregando elétrodos de grafite-epóxi e diamante dopado com boro para a determinação do antibiótico sulfato de gentamicina, substâncias de interesse biológico (naftoquinonas) e do pesticida trifloxistrobina. O diamante dopado com boro (DDB) apresenta características atraentes de detecção eletroquímica que são úteis em aplicações analíticas baseadas em voltametria e amperometria. Possui uma ampla janela de potencial em soluções aquosas que permitiu a quantificação do fungicida trifloxistrobina (em +1744 mV versus Ag/AgCl(KClsat)) por voltametria de onda quadrada (SWV), em um tampão Britton-Robinson (0,04 mol L-1, pH 4,00 )/acetonitrila 70/30 por cento v/v. A curva de adição de analito foi obtida usando amplitude de pulso 40 mV, freqüência de 30 Hz, passo de potencial de 20 mV. O limite instrumental de detecção foi de 1,4 × 10-7 mol L-1 e a faixa linear dinâmica abrangeram três ordens de grandeza (10-7 a 10-5 mol L-1). As amostras foram analisadas com recuperações de cerca de 80 por cento em amostras de suco de laranja e de 92,4 a 104,0 por cento em amostras de água. Um estudo para avaliar potenciais interferentes foi realizado na presença de outros fungicidas. Estudos diagnósticos indicaram que a oxidação da trifloxistrobina em meio aquoso na superfície do DDB é irreversível, envolvendo duas etapas, cada um com dois elétrons. A degradação UV da trifloxistrobina foi avaliada utilizando o método eletroquímico proposto e a cinética de degradação estabelecida com meia-vida de 1.07 min. A amperometria por injeção em batelada (BIA do inglês batch-injection analysis) com o DDB (operando a +2000 mV) foi utilizada para desenvolver um método para a determinação de sulfato de gentamicina. A extração em fase sólida (SPE do inglês solid-phase extraction), utilizando um cartucho empacotado com um polímero impresso molecularmente, tendo a canamicina como molécula molde, foi utilizada para melhorar a seletividade. O tampão acetato (0,01 mol L-1; pH 4,4) foi utilizado como eletrólito suporte. A oxidação do sulfato de gentamicina ocorreu logo após a injeção do analito (60 microlitros) que entra em contato com a superfície do eletrodo. O cartucho de SPE foi muito eficiente na retenção do analito quando comparado com o polímero não-impresso correspondente (NIP). A curva analítica apresentou resposta linear, a precisão instrumental foi inferior a 3 por cento e o limite de quantificação foi de 2,7 × 10-6 mol L-1. A frequência analítica foi de 90 medições h-1 e nenhum efeito de memória foram observados entre as medidas sequênciais. O desempenho do método proposto foi comparado com o obtido por HPLC-UV e com espectrofotometria de absorção molecular (ambos após derivação química do analito com o-ftalaldeído ou com ninhidrina). O método desenvolvido neste trabalho foi aplicado em formulações farmacêuticas injetáveis e em amostras simuladas, com recuperações próximas de 100 por cento. Para a determinação do lapachol foi utilizada a SWV usando um eletrodo de grafite-epoxi feito no laboratório. O meio eletrolítico utilizado foi uma solução aquosa contendo o surfactante catiônico CTAB (1,2 × 10-4 mol L-1), tampão fosfato (4,0 × 10-2 mol L-1, pH 6,0) e KNO3 (1,0 mol L-1). O surfactante catiônico melhorou a difusão e a interação do analito com o eletrodo, produzindo um processo reversível que melhorou a corrente total medida pelo sistema. O sinal do lapachol foi medido a -470 mV, após pré-concentração a 400 mV durante 140 s, usando frequência de 30 Hz, amplitude de pulso de 40 mV com passo de potencial de 20 mV. O limite instrumental de detecção foi de 0,029 mg L-1 e a faixa linear dinâmica abrangeu duas ordens de grandeza. Na presença de beta-lapachona (isômero estrutural), a seletividade foi obtida pela derivada de primeira ordem do sinal SWV. A determinação do lapachol em extrato etanólico de Tabebuia impetiginosa foi realizada após uma s / [en] The present work aimed to develop electroanalytical methods using graphite-epoxy and boron-doped diamond electrodes for the determination of the antibiotic gentamicin sulfate, substances of biological interest (naphthoquinones) and the pesticide trifloxystrobin. Boron doped diamond (BDD) features attractive electrochemical detection characteristics that are useful in analytical applications based on voltammetry and amperometry. It has a wide potential window in aqueous solutions that allowed the quantification of the fungicide trifloxystrobin (in +1744 mV versus Ag/AgCl(KClsat)) by square-wave voltammetry (SWV) in Britton-Robinson buffer (0.04 mol L-1, pH 4.00) / acetonitrile 70/30 percent v/v electrolyte medium. The analyte addition curve was constructed using 40 mV pulse amplitude, 30 Hz frequency, 20 mV step potential. The instrumental limit of detection was 1.4 × 10-7 mol L-1 and the linear dynamic range covered three orders of magnitude (from 10-7 to 10-5 mol L-1). Recoveries of about 80 percent in orange juice samples and 92.4 to 104.0 percent in water samples. A study to evaluate potential interferences was carried out in the presence of other fungicides. Diagnostic studies indicated that the oxidation of trifloxystrobin in aqueous medium, on the surface of the BDD, is irreversible, involving two steps, each of them with two electrons. UV degradation of trifloxystrobin was studied using the proposed voltammetric method and degradation kinetics with a half-life of 1.07 min was established. Batch injection amperometry (BIA) with BDD (operating at +2000 mV) was used to develop a method for the determination of gentamicin sulfate. Solid phase extraction (SPE) using a cartridge packed with a molecular imprinting polymer made with kanamycin as the template molecule, was used to improve the selectivity. The acetate buffer (0.01 mol L-1; pH 4.40) was used as supporting electrolyte. Oxidation of gentamicin sulfate occurred right after the analyte (60 microlitres solution) comes into contact with the surface of the electrode. The SPE cartridge packed with MIP was very efficient in retaining the analyte when compared to the one packed with the corresponding non-printed polymer (NIP). The analytical curve was linear, the instrument accuracy was less than 3 percent and the limit of quantification was 2.7 × 10-6 mol L-1. The analytical frequency was 90 measurements h-1 and no memory effect was observed between sequential measurements. The performance of the proposed method was compared with that obtained by HPLC-UV and molecular absorption spectrophotometry (both after chemical derivatization of the analyte with o-phthalaldehyde or with ninhydrin). The method was applied in injectable pharmaceutical formulations and in simulated samples, with recoveries close to 100 percent. For the determination of lapachol SWV was employed using a graphite-epoxy electrode made in the laboratory. The electrolytic medium used was an aqueous solution containing the cationic surfactant CTAB (1.2 × 10-4 mol L-1), phosphate buffer (4.0 × 10 -2 mol L-1, pH 6.00) and KNO3 (1.0 mol L-1). The cationic surfactant improved the diffusion and interaction of the analyte with the electrode, producing a reversible process that improved the total current measured by the system. The lapachol signal was measured at -470 mV after preconcentration at 400 mV for 140 s, using a 30 Hz frequency, 40 mV pulse amplitude with a step potential of 20 mV. The instrumental limit of detection was 0.029 mg L-1 and the dynamic linear range comprised two orders of magnitude. In the presence of beta-lapachone (structural isomer), the selectivity was obtained by the first-order derivative of the SWV signal. The determination of lapachol in ethanolic extract of Tabebuia impetiginosa was carried out after a simple separation of the analyte by thin layer chromatography. The results are statistically similar (with 95 percent confidence level) with those performed through HPLC-UV. Studies for the simultaneous determination of beta-lapachone and alpha-lapachone were also successful
42

Avalia??o do comportamento eletroqu?mico da cotinina no eletrodo de diamante dopado com boro e estudos para sua determina??o em saliva por amperometria pulsada em fluxo

Alecrim, Morgana Fernandes January 2016 (has links)
Data de aprova??o ausente. / Submitted by Jos? Henrique Henrique (jose.neves@ufvjm.edu.br) on 2016-12-20T14:07:54Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) morgana_fernandes_alecrim.pdf: 1686041 bytes, checksum: c2250fb532be684ddef616d3424c8dc0 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2017-01-17T18:51:10Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) morgana_fernandes_alecrim.pdf: 1686041 bytes, checksum: c2250fb532be684ddef616d3424c8dc0 (MD5) / Made available in DSpace on 2017-01-17T18:51:10Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) morgana_fernandes_alecrim.pdf: 1686041 bytes, checksum: c2250fb532be684ddef616d3424c8dc0 (MD5) Previous issue date: 2016 / A Cotinina (CO) ? o principal metab?lito da nicotina, sendo utilizada como biomarcador para monitorar a exposi??o de um indiv?duo ao tabaco. Os m?todos comumente utilizados para a determina??o desse composto em amostras biol?gicas s?o baseados na cromatografia l?quida, os quais, em geral, s?o dispendiosos e requerem tratamentos tediosos dessas amostras. Dessa maneira, torna-se necess?rio o desenvolvimento de novos m?todos mais simples e r?pidos para determina??o da CO. Nesse contexto, o presente trabalho prop?e o uso eletrodo de diamante dopado com boro (BDD) para detec??o e caracteriza??o eletroqu?mica da CO por t?cnicas voltam?tricas, bem como sua quantifica??o em amostras de saliva por meio da amperometria de m?ltiplos pulsos (MPA) em sistema de an?lise por inje??o em fluxo (FIA). Em meio de tamp?o fosfato a 0,1 mol L-1 (pH 7) a CO apresentou dois processos eletroqu?micos, um an?dico em +1,8 V e um cat?dico em -1,2 V (vs. Ag/ AgCl), sendo o segundo dependente do primeiro e ambos de car?ter irrevers?vel. Foi verificado que o processo de transporte de massas para a oxida??o da CO ? preferencialmente difusional sobre o eletrodo de BDD e que 2 el?trons e pr?tons est?o envolvidos na rea??o eletroqu?mica. O coeficiente de difus?o calculado para a CO foi de 5,7 x 10 -2 cm2 s-1. Para determina??o da CO em saliva, MPA foi utilizada aplicando-se 4 pulsos de potencial, sendo: (1) em +1,8 V/ 400 ms potencial gerador (EG) para oxida??o da CO; (2) em -1,0 V/ 500 ms potencial para elimina??o de interferentes na amostra de saliva, (3) em -1,2 V/ 30 ms potencial coletor para reduzir e quantificar a CO gerada pelo EG; (4) em -145/ 300 ms potencial para limpeza da superf?cie do BDD. A freq??ncia anal?tica te?rica foi obtida de 24 determina??es por hora com uma vaz?o otimizada em 3,0 mL min-1 e a al?a de amostragem de 300 ?L no sistema FIA. Al?m disso, um baixo desvio padr?o relativo de 1,46% foi obtido para 10 determina??es consecutivas de CO 10 ?mol L-1. Nessas condi??es, foi obtida uma faixa linear de 0,5 a 100 ?mol L-1 (R= 0,998) com limite de detec??o calculado em 0,18 ?mol L-1 para CO. Os estudos de adi??o e recupera??o da CO em amostras de saliva foram de 96,77%, Portanto, mediante a caracteriza??o eletroqu?mica e os estudos por FIA-MPA usando eletrodo de BDD, este trabalho apresenta uma alternativa simples, r?pida e de baixo custo para monitoramento do grau de exposi??o ao tabaco pela determina??o da CO em amostras de saliva. / Disserta??o (Mestrado) ? Programa de P?s-gradua??o em Ci?ncias Farmac?uticas, Universidade Federal dos Vales do Jequitinhonha e Mucuri, [2016]. / The Cotinine (CO) is the major metabolite of the nicotine an disused as a biomarker to monitor the exposure of an individual to tobacco. The methods commonly used for CO determination in biological samples are based on liquid chromatography, which generally are expensive and require tedious treatments of the samples. Thus, it becomes necessary to develop simpler and faster methods for determining CO. In this context, this paper proposes the use boron-doped diamond (BDD) film electrode for the detection and electrochemical characterization of CO by voltammetric techniques and, CO quantification in saliva samples by multiple-pulse amperometry (MPA) in analysis by flow injection (FIA) system. In phosphate buffer solution 0.1 mol L-1 (pH 7), the CO presented two electrochemical processes, one anodic at + 1.8V and one cathode at -1.2V (vs. Ag/ AgCl), with the second process dependent on the first and both irreversible process. It was found that CO electrochemical processes are controlled by diffusion and, two-protons and two-electrons are involved in the oxidation reaction. The diffusion coefficients calculated for CO was 5.7 x 10 -2 cm2 s-1. In determination of CO in saliva samples, the MPA detection was used applying four potential pulses: (1) at +1.8V/ 400ms ? generator potential pulse (EG) for oxidation of CO; (2) at-1.0V/500ms - potential for remove possible interferents, (3) at - 1.2V/30ms - collector potential pulse potential for reduction of the product generated by EG and CO quantification; (4) at-14.5V/ 300 ms- potential pulse for cleaning BDD electrode. The proposed method obtained a theoretical analytical frequency with 24 determinations per hour by FIA system in flow rate of 3.0 ml min-1 and sample loop of 300?L. Furthermore, a low relative standard deviation of 1.46% was obtained for 10 measurements of CO 10 ?mol L-1. Under these conditions, A good linear range from 0.5 to 100 ?mol L-1 (R = 0.998) was obtained with a detection limit estimated at 0.18 ?mol L-1 for CO. The addition and recovery studies of CO in saliva samples were 96.77%. Therefore, this work presents, by the first time, an electrochemical characterization of the CO and a method simple, fast and low cost for monitoring the degree of exposure to tobacco by CO determination in saliva samples using FIA-MPA technique.
43

Uso do método do padrão interno em sistemas FIA e BIA e determinação simultânea de diclofenaco e codeína em formulações farmacêuticas por amperometria de múltiplos pulsos / Use of the internal standard method in FIA and BIA systems and determination of diclofenac and codeine in pharmaceutical formulations by multiple pulse amperometry

Gimenes, Denise Tofanello 25 July 2013 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / The present thesis demonstrates, for the first time, the possibility of using of the internal standard method in FIA or BIA systems with amperometric detection. The method allows to obtain accurate results in the presence of fluctuations in the system parameters (injected volume, dispensing rate, ionic strength and accidental insertion of air bubbles) and in the presence of contamination and/or gradual passivation of the working electrode surface. Methods for determination of diclofenac (DCF) using FIA with amperometric detection and simultaneous determination of DCF and codeine (CO) by BIA with amperometric detection have also been developed. The internal standard method was implemented in the flow injection analysis with multiple pulse amperometric detection (FIA-MPA) system by applying a sequence of potential pulses of the working electrode as a function of time. The analyte (+0.80 V/300ms) and internal standard (-0.05 V/400ms) were detected selectively, one at each potential pulse. Significant improvements were obtained in the accuracy of the system when the results before and after normalization (using the internal standard method), were compared. The following errors were calculated, respectively, before and after normalization of the results using the internal standard method. Change in flow rate from 3.0 to 1.0 ml min-1 (-57% e < 1%); volume injection from 300 to 100 &#956;L (-63% and 3%); ionic strength from 0.60 to 0.77 mol L-1 (-44 and 0,2%) and before and after the introduction of air bubbles into the system (-9,6% and 1,7%). A significant improvement was also obtained in the correlation coefficient of the calibration curve in the presence of problems of passivation or contamination of the working electrode. The correlation coefficient was calculated, respectively, as 0,975 and 0,998, before and after the normalization of the results by the IS method. The internal standard method was also applied to correct errors derived from the injection procedure (dispensing rate and injected volume) in batch injection analysis systems (BIA) with amperometric detection when disposable syringes were used. The results obtained before and after normalization of the results by the IS method were the following, respectively: repeatability test (RSD = 6.4 and 1.8%; n = 8), correlation coefficients (R=0.954 and 0.997) and errors obtained in analysis of synthetic samples (E = 9.4 ± 1.5 and 3.5 ± 0.7%; n = 8). The determination of DCF by FIA-MPA was implemented by applying two potential pulses to the BDD electrode using H2SO4 0.1 mol L-1 as supporting electrolyte: (i) + 1.2 V / 50 ms for oxidation and quantification of DCF, and (ii) 0.0 V / 50 ms for constant electrochemical cleaning of the electrode surface. The system showed good stability (RSD = 1.0%, n = 10) and high analytical frequency (135 injections h-1). The method showed a linear response between 5 and 50 &#956;mol L-1 and the detection and quantification limits were as 0.14 and 0.46 mmol L-1, respectively. The proposed method was applied to determine of DCF in pharmaceutical formulations and the obtained results were similar to those obtained by HPLC with a confidence level of 95%. The simultaneous determination of DCF and CO was performed using the following potential pulses: (i) +1.1 V / 50 ms: oxidation and quantification of DCF; (ii) +1.4 V / 50 ms: simultaneous oxidation of DCF and CO, (iii) 0.0 V / 200 ms: for constant electrochemical cleaning of the BDD electrode. The oxidation current from CO was obtained by the difference between currents detected at 1.4 and 1.1 V by using a correction factor. The system showed good stability (RSD = 0.9% and 1.1 for DCF and CO respectively, n = 10) and high analytical frequency (~ 300 injections h-1). The method showed a linear response between 10 and 50 &#956;mol L-1 for DCF and 7.1 and 35.7 &#956;mol L-1 for CO. The LQ and LD were calculated, respectively, at 1.1 and 3.7 &#956;mol L-1, for DCF and 1.0 and 3.3 mol L-1 for CO. The proposed method was applied for simultaneous determination of DCF and CO in pharmaceutical formulations and the obtained results were similar to those obtained by HPLC with a confidence level of 95%. Keywords: Multiple pulse amperometry, FIA, BIA, internal standard, simultaneous analysis, boron doped diamond (BDD), codeine, diclofenac. / Esta tese apresenta, pela primeira vez, a possibilidade de usar o método do padrão interno em sistemas FIA ou BIA com detecção amperométrica. O método permite a obtenção de resultados precisos na presença de flutuações em parâmetros dos sistemas (volume injetado, velocidade de injeção, força iônica e inserção acidental de bolhas de ar) e na presença de contaminação e/ou passivação gradual do eletrodo de trabalho. Métodos para determinação de diclofenaco (DCF) usando FIA com detecção amperométrica e simultânea de DCF e codeína (CO) por BIA com detecção amperométrica também foram desenvolvidos. O método do padrão interno foi implementado no sistema de análise por injeção em fluxo com detecção por amperometria de múltiplos pulsos (FIA-MPA) mediante a aplicação de uma sequência de pulsos de potenciais ao eletrodo de trabalho em função do tempo. O analito (+0,80 V/300ms) e o padrão interno (-0,05 V/400ms) foram detectados seletivamente, um em cada pulso de potencial. Melhoras significativas foram obtidas na precisão do método quando os resultados obtidos antes e após a normalização (usando o método do padrão interno) foram comparados. As seguintes variações foram calculadas, respectivamente, antes e após a normalização dos resultados usando o método do padrão interno. Variação na velocidade de vazão de 3,0 para 1,0 mL min-1 (-57% e < 1%); no volume de injeção de 300 para 100 &#956;L (-63% e 3%); força iônica de 0,60 para 0,77 mol L-1 (-44 e 0,2%) e antes e após a inserção de bolhas de ar no sistema (-9,6% e 1,7%). Uma melhora significativa também foi obtida no coeficiente de correlação da curva de calibração na presença de problemas de passivação ou contaminação do eletrodo de trabalho. O coeficiente de correlação foi calculado, respectivamente, em 0,975 e 0,998, antes e após a normalização dos resultados pelo método do PI. O método do padrão interno também foi aplicado para corrigir erros em sistemas de análise por injeção em batelada (BIA) com detecção amperométrica provenientes do procedimento de injeção (velocidade de injeção e volume injetado) quando seringas descartáveis foram utilizadas. Os resultados obtidos antes e após a normalização dos resultados pelo método do PI foram os seguintes, respectivamente: estudo de repetibilidade (DPR=6,4 e 1,8%; n = 8), coeficientes de correlação (R=0,954 e 0,997) e erros obtidos na análise de amostras sintéticas (9,4 ± 1,5% e 3,5 ± 0,7; n = 8). A determinação de DCF por FIA-MPA foi implementada através da aplicação de dois pulsos de potenciais ao eletrodo de BDD em meio de H2SO4 0,1 mol L-1 como eletrólito suporte: (i) +1,2 V / 50 ms para oxidação e quantificação do DCF e, (ii) 0,0 V / 50 ms para constante limpeza eletroquímica do eletrodo de trabalho. O sistema apresentou boa estabilidade (RSD = 1,0%; n=10) e elevada frequência analítica (135 injeções h-1). O método apresentou resposta linear entre 5 e 50 &#956;mol L-1 e os limites de detecção e quantificação foram calculados em 0,14 e 0,46 &#956;mol L-1, respectivamente. O método proposto foi aplicado na determinação de DCF em formulações farmacêuticas e os resultados obtidos foram similares ao obtidos por HPLC a um nível de confiança de 95%. A determinação simultânea de DCF e CO foi realizada usando os seguintes pulsos de potenciais: (i) +1,1 V / 50 ms: oxidação e quantificação de DCF; (ii) +1,4 V / 50 ms: para oxidação simultânea de DCF e CO; (iii) 0,0 V / 200 ms: para constante limpeza eletroquímica do eletrodo de BDD. A corrente de oxidação da CO foi obtida pela subtração entre as correntes detectadas em 1,4 e 1,1 V mediante uso de um fator de correção. O sistema apresentou boa estabilidade (RSD= 1,1 e 0,9% para DCF e CO, respectivamente, n=10) e elevada frequência analítica (~300 injeções h-1). O método apresentou resposta linear entre 10 e 50 &#956;mol L-1 para o DCF e entre 7,1 e 35,7 &#956;mol L-1 para CO. O LD e o LQ foram calculados, respectivamente, em 1,1 e 3,7 &#956;mol L-1, para DCF e 1,0 e 3,3 &#956;mol L-1 para CO. O método proposto foi aplicado na determinação simultânea de DCF e CO em formulações farmacêuticas e os resultados obtidos foram similares ao obtidos por HPLC a um nível de confiança de 95%. / Doutor em Química
44

Caracterização espectroscópica, microscópica e eletroquímica de eletrodos modificados com diferentes nanotubos de carbono para a detecção de catecol e dopamina

Lima, Ana Paula de 16 February 2017 (has links)
Os nanotubos de carbono (CNTs) possuem várias aplicações devido às suas propriedades com destaque à alta resistência química, baixa densidade e elevada condutividade elétrica. Dentro da Química Analítica, destacam-se as propriedades eletrocatalíticas destes nanomateriais para a modificação da superfície de eletrodos de trabalho, e assim atuarem como sensores eletroquímicos. Este trabalho investiga a utilização de três tipos de CNTs, um de paredes simples (SWCNT) e dois de paredes duplas (DWCNT), sendo um destes de menor comprimento (S-DWCNT), para a modificação do eletrodo de carbono vítreo (GCE). Inicialmente, a caracterização dos CNTs não funcionalizados e funcionalizados foi realizada com o intuito principal de analisar as possíveis mudanças obtidas pelo processo de funcionalização. As caracterizações foram feitas através de espectroscopia na região do infravermelho (IR) e espectroscopia Raman. As morfologias destes materiais foram avaliadas por microscopia eletrônica de varredura (SEM). A estabilidade térmica foi observada pela análise termogravimétrica. Posteriormente à etapa de caracterização dos CNTs, investigou-se o comportamento eletroquímico dos compostos fenólicos catecol (CT) e dopamina (DP) em eletrodos modificados com os três diferentes CNTs. O estudo do pH do eletrólito indicou melhores resultados em termos de corrente com a solução de HClO4. O estudo da velocidade de varredura de voltamogramas cíclicos indicou que os processos de oxidação eletroquímica são controlados ora por difusão das espécies ao eletrodo ora por processos adsortivos. A detecção amperométrica das espécies em sistema de análise por injeção em batelada (BIA) foi avaliada utilizando eletrodos modificados com os três CNTs. Obtiveram-se amplas faixas lineares de 1-1000 μmol L- 1 tanto para CT como para DP, em todos os casos. Para CT e DP, baixos desvios padrão foram obtidos para injeções consecutivas (n=15) de aproximadamente 1,0% para GCE, SWCNT, DWCNT e S-DWCNT. Frequências analíticas de 135 h-1 foram obtidas empregando-se os eletrodos modificados, enquanto que em GCE obteve-se 105 h-1. Baixos limites de detecção para CT (0,0093; 0,0136; 0,0715 μmol L-1) e DP (0,0145; 0,0493; 0,1743 μmol L-1) foram obtidos em SWCNT, DWCNT e S-DWCNT, respectivamente, enquanto que em GCE foram obtidos 0,867 e 1,034 para CT e DP, respectivamente. Todos resultados obtidos mostraram-se promissores, com faixas lineares amplas e DLs baixos, manifestando assim que as modificações em GCE com os CNTs foram eficientes e resultaram em sensores eletroquímicos mais sensíveis para os analitos investigados. / Carbon nanotubes (CNTs) have various applications due to their properties with emphasis to high chemical resistance, low density and high electrical conductivity. Within Analytical Chemistry, the electrocatalytic properties of these nanomaterials are highlighted towards the the surface modification of working electrodes, and thus act as electrochemical sensors. This work investigates the use of three types of CNTs, a single-walled (SWCNT) and two double walled carbon nanotubes (DWCNT), one of these of smaller length (S-DWCNT), for the modification of a glassy carbon electrode (GCE). Initially, the functionalized and non-functionalized CNTs were characterized aiming to analyze the possible changes obtained by functionalization process. The characterizations were made through infrared (IR) and Raman spectroscopies. The morphologies of these materials were evaluated by scanning electron microscopy (SEM). The thermal stability was observed by thermogravimetric analysis. After the step of characterizing the CNTs, it was investigated the electrochemical behavior of the phenolic compounds catechol (CT) and dopamine (DP) on electrodes modified with three different CNTs. The study of pH of the electrolyte showed best results in terms of current for HClO4 solution. Study of cyclic voltammetry scan rate indicated that the electrochemical oxidation processes are controlled either by diffusion of the species to the electrode or by adsorptive processes. The amperometric detection analysis of the species using a batch injection system (BIA) was carried out using three CNTs modified electrodes. It was obtained wide linear ranges of 1-1000 μmol L- 1 for both CT and DP in all cases. For CT and DP, low standard deviations were obtained for consecutive injections (n = 15) of approximately 1.0% on GCE, SWCNT, DWCNT and S-DWCNT. Analytical frequencies of 135 h-1 were obtained employing the modified electrodes, while in GCE was obtained 105 h-1. Low detection limits for CT (0.0093; 0.0136; 0.0715 μmol L-1) and DP (0.0145; 0.0493; 0.1743 μmol L-1) were obtained in SWCNT, DWCNT and S-DWCNT, respectively, while in GCE 0.867 and 1.034 μmol L-1 were obtained for CT and DP, respectively. All results proved to be promising, with wide linear ranges and low DLs, thus manifesting that the modifications of GCE with CNTs were efficient and resulted in more sensitive electrochemical sensors for the analytes investigated. / Dissertação (Mestrado)
45

Estudo da autoxidação dos complexos de Cu(II), Ni(II) e Co(II)/tetraglicina induzida por S(IV) / Study of the autoxidation of the complexes of Cu (II), Ni (II) and Co (II)/tetraglycine induced by S(IV)

Maria Vespertina Alipazaga Sebastian 19 September 2003 (has links)
O presente trabalho apresenta estudos espectrofotométricos relacionados à autoxidação dos complexos de Cu(II), Ni(II) e Co(II)/tetraglicina induzida por sulfito. Nossos estudos verificaram que a autoxidação de Cu(II)/tetraglicina (1,0x10-3 mol L-1) em pH = 9,0 (tampão borato) é afetada pela presença de traços de Ni(II) ou Co(II). Na ausência de Ni(II) ou Co(II), a reação é muito ineficiente e lenta com períodos de indução longos (aproximadamente 4 h). Ni(II) ou Co( II) em concentrações baixas ( 10-5 - 10-6 mol L-1) afetam significativamente a cinética: o período de indução diminui drasticamente (a menos de 2 s) e a formação de Cu(III) é fortemente acelerada com simultâneo aumento da eficiência da reação. A atividade catalítica e o sinergismo positivo de Co(II) e Ni(II) podem ser explicados pela oxidação mais rápida de Co(II) ou Ni(II)/tetraglicina pelo oxigênio dissolvido. O processo eletroquímico relacionado aos sistemas Cu(II)/Cu(III)/tetraglicina e Ni(II)/Ni(III)/tetraglicina são reversíveis, possibilitando monitorá-los adequadamente mediante o uso da técnica de eletrodo rotativo disco-anel. Entretanto, o sistema Co(II)/Co(III)/tetraglicina é irreversível. Esses estudos mostraram que as espécies de Cu(III) e Ni(III) geradas no eletrodo disco são instáveis nas condições experimentais empregadas. O efeito sinérgico positivo na presença de Ni(II) (que permitiu aumentar a sensibilidade) foi aproveitado para desenvolvimento de método espectrofotométrico e amperométrico simples e sensível para a determinação indireta de sulfito em meio aquoso. O método espectrofotométrico está baseado na medida de absorbância do complexo de Cu(III)/tetraglicina (gerado na presença de sulfito e traços de Ni(II)) em 365 nm. O método amperométrico em análise por injeção em fluxo baseia-se na medida de corrente (0,1 V vs Ag/AgCl) em função da concentração de Cu(III)/tetraglicina gerado quimicamente, na presença de sulfito e traços de Ni(II). Os métodos desenvolvidos foram empregados para a determinação de S(IV), em vinhos e sucos, após a sua extração da amostra acidificada, os resultados obtidos concordaram com aqueles obtidos pelo método iodométrico. / The present work presents spectrophotometric studies related to the sulfite induced autoxidation of Cu(II), Ni(II) and Co(II)/tetraglycine complexes. The sulfite induced autoxidação of Cu(II)/tetraglycine (1.0x10-3 mol L-1) at pH = 9.0 (borate buffer) is affected by the presence of small quantities of the Ni(II) or Co(II). In the absence of added nickel (II) or cobalt (II), the reaction is very inefficient and slow with one large induction period (about 4 h). Trace amounts of Ni(II) or Co(II) (10-5 - 10-6 M) affect the kinetic significantly: the induction period drastically decreases (less than 2 s) and the formation of Cu(III) is strongly accelerated. The effectiveness of Cu(III) formation becomes much higher. The catalytic activity and the positive synergism of Co(II) and Ni(II) may be explained by the faster oxidation of Co(II) or Ni(II)/tetraglycine complexes by dissolved oxygen. The electrochemistry of Cu(II)/Cu(III)/tetraglycine and Ni(II)/Ni(III)/tetraglycine systems are reversible, such as it was possible to monitor them by using the rotating ring-disk electrode technique. However, the Co(II)/Co(III)/tetraglycine system is irreversible. Those studies showed that the Cu(III) and Ni(III) species generated on the disk electrode are unstable in the employed experimental conditions. The positive sinergistic effect in the presence of Ni(II) (which allowed to increase the sensibility) was taken in advantage for development of one simple and sensitive spectrophotometric and amperometric method for indirect determination of sulfite in aqueous medium. The spectrophotometric method is based on the absorbance measurement of the Cu(III)/tetraglicyne complex (generated in the presence of sulfite and small quantities of Ni(II)) at 365 nm. The amperometric method by flow injection analysis is based on the current measurement (0.1 V vs Ag/AgCl) as function of Cu(III)/tetraglycine concentration chemically generated, in the presence of sulfite and Ni(II). The methods were employed for the determination of S(IV), in wines and juices, after its extraction from acidified samples and the results were in agreement with those obtained by the iodometric procedure.
46

Novos materiais para aplicações analíticas nas determinações de compostos orgânicos de interesse farmacêutico e ambiental / New materials for analytical application in organic compound determination for pharmaceutical and environmental interests

Fabiana da Silva Felix 19 June 2009 (has links)
Sensores de filme de carbono, construídos a partir de resistores com 2 &#937; de resistência nominal, foram utilizados para aplicações em áreas de interesse ambiental e farmacêutico sem a modificação prévia de suas superfícies. Através de um tratamento eletroquímico em meio ácido, é possível obter uma faixa de potencial (para ambos os limites anódico e catódico) maior comparado aos eletrodos de carbono convencionalmente utilizados. Devido ao fato dos sensores serem confeccionados em escala industrial na Alemanha, seu custo é muito baixo, tornando possível sua utilização na forma de eletrodos descartáveis. Além disso, são caracterizados por uma grande versatilidade, reprodutibilidade e estabilidade. Para comprovar a viabilidade dos eletrodos de filme de carbono como transdutores voltamétricos, amostras de paraquat foram analisadas em águas de rio e potável. A associação com a voltametria de onda quadrada possibilitou obter um limite de detecção inferior ao limite máximo estabelecido para o herbicida em água potável. Estudos por voltametria cíclica mostraram dois picos para a redução do paraquat, similares aos descritos na literatura. Os sensores de filme de carbono também foram adaptados ao sistema de análise por injeção em fluxo para a determinação amperométrica de paracetamol e de ambroxol em formulações farmacêuticas. Em ambos os estudos, foi possível obter ampla faixa linear de concentração, baixos limites de detecção e sensibilidade elevada. Estudos de repetibilidade com os dois analitos apresentaram desvios padrões relativos de até 3%, comprovando a ausência de efeito de memória. Os resultados obtidos durante as análises em fluxo com os novos sensores amperométricos concordaram com as metodologias descritas nas farmacopéias. Ao longo dos quatro anos de doutoramento também foram desenvolvidos outros estudos, os quais estão descritos nos apêndices desta tese. / Carbon film sensors, built from resistors of 2 &#937; nominal resistance, were employed for application in the environment and pharmaceutical fields without previous modification of the electrode surface. When these sensors are electrochemically treated they obtain a wider potential window (both anodic and cathodic regions) than many other forms of carbon. Due to the fact that sensors are produced on industrial scale in Germany, the cost of each unit is very low, a feature that enables the use of these electrodes in disposable form. Moreover, they have great versatibility, reproducibility and stability. To prove the suitability of the carbon film electrodes as voltammetric sensors paraquat samples were analysed in river and drinking water. The association with the square wave voltammetry led to a detection limit below the allowed upper limit for herbicide analysis in drinking water. Previous results with cyclic voltammetry showed two peaks for paraquat reduction, in agreement with the literature data. The carbon film sensors were also adapted to the flow injection analysis system for amperometric determination of acetaminophen and ambroxol in pharmaceutical formulations. It was possible to obtain a wide linear working range, low detection limit and high sensitivity for both analytes. During the repeatabilty studies, acetaminophen and ambroxol showed relative standard desviations lower than 3% without any memory effect. The results obtained with a new amperometric sensor associated to FIA were in good agreement with those recommended by pharmacopoeias. In the appendices of this thesis are described other studies which have been developed for four years of PhD.
47

[pt] DESENVOLVIMENTO DE MÉTODOS ELETROANALÍTICOS PARA A DETERMINAÇÃO DE FUNGICIDAS DA CLASSE DAS ESTROBILURINAS UTILIZANDO ELETRODOS DE FILME DE BISMUTO E DE DIAMANTE DOPADO COM BORO / [en] ELECTROANALYTICAL METHODS FOR THE DETERMINATION OF FUNGICIDES OF THE STROBILURIN CLASS USING THE BISMUTH FILM ELECTRODE AND THE BORON-DOPED DIAMOND

29 November 2021 (has links)
[pt] O monitoramento de resíduos de pesticidas é extremamente importante e isso se dá pelo emprego de métodos analíticos adequados para avaliar a sua presença em compartimentos ambientais e a contaminação de alimentos com esses agentes. Os pesticidas da classe das estrobilurinas vêm se tornando os mais utilizados para o controle dos fungos e apesar da propagada baixa toxicidade e rápida degradação, estudos devem ser realizados para averiguar o nível de exposição dos humanos a tais substâncias. Estudos com as estrobilurinas (azoxistrobina, cresoxim-metílico, dimoxistrobina, fluoxastrobina, picoxistrobina, piraclostrobina e trifloxistrobina) utilizando o eletrodo de trabalho de diamante dopado com boro (DDB) foram realizados por voltametria cíclica e voltametria de onda quadrada (SWV) e indicaram dois picos de oxidação (varredura anódica) em potenciais distintos. Dados experimentais e da literatura permitiram supor que para cresoxim-metílico e dimoxistrobina o primeiro pico de oxidação tem um mecanismo irreversível com 2 mols de elétrons por mol de analito e o segundo pico de oxidação com mecanismo quase-reversível. Para picoxistrobina, os dois picos de oxidação são irreversíveis com 2 mols de elétrons por mol de analito. Para piraclostrobina os dois picos de oxidação são quase-reversíveis. Métodos por SWV foram desenvolvidos utilizando DDB para determinação de cresoxim-metílico, picoxistrobina e piraclostrobina. As varreduras anódicas foram feitas entre: +1000 a +1750 mV (medição do sinal em +1420 mV) para cresoxim-metílico; +1100 a +1800 mV (medição do sinal em +1450 mV) para picoxistrobina e +1050 a +2100 mV (medição do sinal em +1280 mV) para piraclostrobina. O eletrólito suporte foi tampão acetato (0,05 mol L-1; pH 4,0) para a determinação de cresoxim-metílico e piraclostrobina e tampão Britton-Robinson (0,04 mol L-1; pH 2,0) para a picoxistrobina. Resposta analítica linear para cresoxim-metílico foi do limite de quantificação, LOQ, (0,9 umol L-1 ou 0,27 mg L-1) até 34,0 μmol L-1 com R2> 0,999. Para picoxistrobina a faixa linear foi do LOQ (0,7 mol L-1 ou 0,25 mg L-1) a 20,0 μmol L-1 (R2> 0,994). Já para piraclostrobina a faixa linear foi do LOQ (0,8 μmol L-1 ou 0,32 mg L-1) a 20,0 μmol L-1 (R2> 0,991). Os métodos foram aplicados na análise de amostras de suco de uva (cresoxim-metílico e piraclostrobina) e águas naturais (picoxistrobina e piraclostrobina). As recuperações variaram de 91,6 a 105,3 porcento dependendo da estrobilurina. Os métodos propostos foram comparados com cromatografia líquida de alta eficiência (HPLC) e os resultados não indicaram diferença significativa entre eles. Amostras de suco de uva comercial foram fortificadas na concentração do limite máximo permitido pela legislação, sendo o analito pré-concentrado dez vezes por extração em fase sólida (SPE), com cartucho C18, obtendo-se recuperações entre 95,4 a 99,5 porcento dependendo da estrobilurina. Dados experimentais indicaram que não houve degradação térmica significativa para as estrobilurinas em soluções aquecidas a 60 °C durante 2 h. Não foi possível propor um perfil simples de cinética para degradação por exposição ao UV para o cresoxim-metílico. Para picoxistrobina e piraclostrobina, um modelo de cinética de segunda ordem pode ser atribuído para a degradação por exposição ao UV. Métodos com a abordagem de análise por injeção em batelada (BIA) com detecção amperométrica no eletrodo de DDB foram desenvolvidos para a determinação de dimoxistrobina e picoxistrobina em águas naturais. Os métodos apresentaram uma frequência de análise de 180 injeções h-1 (dimoxistrobina) e 108 injeções h-1 (picoxistrobina), e precisão satisfatória (abaixo de 5 porcento). Resposta analítica linear para dimoxistrobina foi de 1,3 μmol L-1 (0,41 mg L-1) a 60,0 μmol L-1 com R2> 0,999 e para picoxistrobina foi de 5,3 μmol L-1 (1,95 mg L-1) e 100,0 μmol L-1 (R2> 0,999). Valores de recuperação obtidos nas amostras de águas naturais fortificadas com os analitos foram entre 80,2 e 105,6 porcento dependendo do analito. Além disso, uma estratégia simples para detectar a presença de moléculas interferentes em amostras de água com base na amperometria de múltiplos pulsos foi apresentada com sucesso. Um método voltamétrico de redissolução anódica por pulso diferencial usando o eletrodo de filme de bismuto foi desenvolvido para a determinação de picoxistrobina em amostras de urina e águas naturais. O ciclo de medição começou com a aplicação de um potencial de deposição de -700 mV durante 60 s para a formação in situ do filme Bi e a acumulação do analito. A varredura de potencial foi no sentido anódico entre +790 e +1050 mV. Provou-se que, nas condições empregadas, uma quantidade significativa de filme de Bi ainda está presente na superfície do eletrodo de carbono vítreo após a varredura anódica, com uma velocidade de 40 mV s-1. A presença de Bi é fundamental para a acumulação e oxidação de picoxistrobina (pico máximo em +954 mV) durante redissolução. O eletrólito suporte foi HCl 1,0 mol L-1. Um procedimento de limpeza foi desenvolvido a fim de minimizar o efeito de memória. Resposta analítica linear para picoxistrobina foi observada de 2,8 μmol L-1 (1,0 mg L-1) até 19,0 μmol L-1 (R2> 0,994). SPE permitiu a pré-concentração do analito e eliminou as interferências nas amostras de urina. Recuperações de 89,3 a 104,8 porcento foram encontradas e a interferência das outras estrobilurinas ao método foram avaliadas. O método proposto foi comparado com HPLC e os resultados indicam que não houve diferença significativa entre eles. / [en] The monitoring of pesticide residues is extremely important and this is accomplished by the use of methods to assess their presence in environmental compartments and in food stuff contaminated with these agents. The pesticides of the strobilurin class have become the most widely used for fungi control and despite the low toxicity and rapid degradation, studies should be conducted to ascertain the level of human exposure to such substances. Studies with the strobilurin pesticides (azoxystrobin, kresoxim-methyl, dimoxystrobin, fluoxastrobin, picoxystrobin, pyraclostrobin and trifloxystrobin) were performed by cyclic voltammetry and square wave voltammetry (SWV) using the boron-doped diamond (BDD). Results indicated two oxidation peaks (anodic scan) at different potentials. Based on experimental data and literature it is assumed that for kresoxim-methyl and dimoxystrobin the first oxidation peak comes from an irreversible mechanism involvieng 2 moles of electrons per mole of analyte while the second oxidation peak is from a quasi-reversible mechanism. For picoxystrobin, the two oxidation peaks are from irreversible processes involving 2 moles of electrons per mole of analyte. For pyraclostrobin, the two oxidation peaks are from quasi-reversible processes. SWV methods were developed for determination of kresoxim-methyl, pyraclostrobin and picoxystrobin using the BDD. The anodic scans were made between: +1000 to +1750 mV (measured signal at +1420 mV) for kresoxim-methyl; +1100 to +1800 mV (measured signal at +1450 mV) for picoxystrobin and +1050 to +2100 mV (measured signal at +1280 mV) for pyraclostrobin. The supporting electrolyte was acetate buffer (0.05 mol L-1, pH 4.0) for the determination of kresoxim-methyl and pyraclostrobin and Britton-Robinson buffer (0.04 mol L-1, pH 2.0) to picoxystrobin. Linear analytical response to kresoxim-methyl was the limit of quantification, LOQ (0.9 μmol L-1 or 0.27 mg L-1) to 34.0 μmol L-1 with R2> 0.999. For picoxystrobin the linear range was from LOQ (0.7 μmol L-1 or 0.25 mg L-1) to 20.0 μmol L-1 (R2> 0.994). Pyraclostrobin presented linear range from LOQ (0.8 μmol L-1 and 0.32 mg L-1) to 20.0 μmol L-1 (R2> 0.991). The methods were applied in the analysis of grape juice samples (kresoxim-methyl and pyraclostrobin) and in natural waters (picoxystrobin and pyraclostrobin). The recoveries ranged from 91.6 to 105.3 percent depending on the strobilurin. The results obtained with the proposed methods were compared with the ones achieved by high performance liquid chromatography (HPLC) indicating no significant difference between them. Commercial grape juice samples were fortified at the maximum concentration allowed legislation and the analytes were pre-concentrated (tenfold) by solid phase extraction (SPE) in a C18 cartridge analyte Recoveries were between 95.4 to 99.5 percent depending on the strobilurin. Experimental data indicate that no significant thermal degradation occurred for strobilurins in solutions heated at 60 °C for 2 h. It was not possible to propose a simple kinetic profile for the UV degradation of kresoxim-methyl. However, for picoxystrobin and pyraclostrobin, a second-order kinetic model explains their degradation profile. Methods using batch injection analysis (BIA) with amperometric detection on a BDD electrode have also been developed for the determination of picoxystrobin and dimoxystrobin in natural waters. The methods showed an analytical frequency of 180 injections h-1 (dimoxystrobin) and 108 injections h-1 (picoxystrobin) and satisfactory precision (less than 5 percent). Linear analytical response for dimoxystrobin was from 1.3 μmol L-1 (0.41 mg L-1) to 60.0 μmol L-1 with R2> 0.999 while for picoxystrobin, the range was from 5.3 μmol L-1 (1.95 mg L-1) to 100.0 μmol L-1 (R2> 0.999). Recoveries achieved for analyte fortified water samples were between 80.2 and 105.6 percent depending on the analyte. In addition, a simple strategy to detect the presence of interfering molecules in water samples, based on multiple pulse amperometry, was successfully introduced. A stripping anodic differential pulse voltammetric method using the bismuth film electrode was developed for the determination picoxystrobin in urine samples and in natural waters. The measurement cycle started with the application of a deposition potential of -700 mV for 60 s for the in situ formation of the Bi film and for the accumulation of analyte. The potential was scanned in the anodic direction between +790 and +1050 mV. It has been proven that, under the conditions employed, a significant amount of Bi film is still present on the surface of the glassy carbon electrode after anodic sweep, with a speed of 40 mV s-1. The presence of Bi is essential for the accumulation and oxidation of picoxystrobin (maximum peak at +954 mV) during stripping. The supporting electrolyte was HCl 1.0 mol L-1. A cleaning procedure was developed to minimize the memory effect. Analytical linear response was observed for picoxystrobin from 2.8 μmol L-1 (1.0 mg L-1) to 19.0 μmol L-1 (R2> 0.994). SPE allowed the pre-concentration of the analyte and elimination of interferences from urine samples. Recoveries from 89.3 to 104.8 percent were found. Interference of other strobilurin the method were evaluated. The proposed method was compared with HPLC and the results indicate no significant difference between them.
48

Utilização de eletrodos de Cu e Au em eletroanalítica: detecção amperométrica de etanol em ar exalado e outras aplicações / Utilization of gold and copper electrodes in electroanalysis: amperometric detection of ethanol in breath and other applications

Paixão, Thiago Regis Longo Cesar da 12 March 2004 (has links)
A potencialidade do eletrodo de cobre em meio alcalino foi demonstrada para o determinação de etanol a +0,6 V vs Ag/AgCl. A participação de espécies solúveis de Cu(III) no processo eletrocatalítico envolvendo a oxidação do etanol foi demonstrada por experimentos utilizando eletrodo disco-anel. A influência do potencial de pré-tratamento no sinal anódico foi investigada e correlacionada com a morfologia dos filmes formados na superfície do eletrodo por EDS (Energy Dispersive X-Ray Spectroscopy), indicando que as espécies de Cu(III) são originadas a partir da oxidação da camada de CuO. As medidas de etanol foram realizadas por amperometria em 0,6 V (vs Ag/AgCl). A repetibilidade das medidas utilizando padrão aquoso de etanol 0,05 % (v/v) foi de 3 % (v/v) e os limites de detecção e quantificação foram de 0,005 % (v/v) e 0,01 % (v/v), respectivamente. Nas condições experimentais otimizadas, o sensor amperométrico foi utilizado para o monitoramento da concentração de etanol no ar exalado (BrAC), que foi convenientemente coletado em um balão de borracha (V = 3 L) e introduzido em uma solução de NaOH 1 mol L-1 (V = 10 mL). O sensor apresentou uma faixa linear para concentrações de etanol em ar exalado na faixa de 0,26 – 130 mg L-1, operando de acordo com os parâmetros analíticos especificados na Legislação Brasileira para a quantificação de etanol no ar exalado em condutores de veículos automotores. A constante de eliminação de etanol do corpo humano também foi investigada e os resultados concordaram com os valores da literatura. Empregando-se eletrodos de Cu e Au foram também desenvolvidas outras metodologias para a quantificação de dipirona, glicose e ácido ascórbico e sistemas em fluxo. Estudos sobre o desenvolvimento e propriedades de um sistema gerador-coletor foram realizados e o dispositivo foi utilizado em titulações de substâncias redutoras com iodo gerado eletroquimicamente. / A copper disc working electrode in alkaline solutions was demonstrated to act as a suitable amperometric sensor for ethanol determination at +0.6 V vs Ag/AgCl. The participation of free-soluble Cu(III) species in the electrocatalytic process involving the anodic oxidation of ethanol has been demonstrated by rotating ring-disc electrode voltammetry. The influence of the pretreatment potential on the anodic signal was investigated and a correlation with the morphology of the electrode surface characterized by Energy Dispersive X-Ray Spectroscopy (EDS) indicated that the Cu(III) species is originated from the oxidation of a CuO layer. Ethanol measurements were performed in the amperometric mode at 0.6 V (vs Ag/AgCl). The repeatability of the measurements for a 0.05 % aqueous ethanol solution was estimated as 3 %, and the detection and quantification limits were determined as 0.005 % and 0.01 %, respectively. At the optimum experimental conditions, the amperometric sensor was used to monitor the concentration of ethanol in breath (BrAC), which was conveniently collected in a rubber air balloon (volume = 3 L) and introduced in a 1 mol L-1 NaOH working solution (volume = 10 mL). The sensor can measure a person\'s breath ethanol over the concentration range 0.26 - 130 mg L-1 by operating it according to an established protocol, of which the analytical parameters are specified by the Brazilian Legislation for BrAC measurements in drivers. The rate of ethanol degradation in the body was followed, and the results agree with predictions in the literature. Methodologies for the determination of dipyrone, glucose and ascorbic acid were also developed by using Cu and Au electrodes. Features of a dual-band electrochemical cell were investigated towards the development of a generator-collector system, which was employed in titrations with electrogenerated iodine.
49

Determina??o da teofilina, clindamicina, varfarina e verapamil por amperometria pulsada em sistema de an?lise por inje??o em batelada usando o eletrodo de diamante dopado com boro

Andrade, Glauber Ant?nio dos Reis 24 March 2016 (has links)
?rea de concentra??o: Qu?mica anal?tica. / Submitted by Jos? Henrique Henrique (jose.neves@ufvjm.edu.br) on 2016-12-21T13:02:41Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) glauber_antonio_reis_andrade.pdf: 2400963 bytes, checksum: 99ec593844d6ba3a1107158d86656739 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2017-01-21T11:09:00Z (GMT) No. of bitstreams: 2 license_rdf: 9 bytes, checksum: 42dd12a06de379d3ffa39b67dc9c7aff (MD5) glauber_antonio_reis_andrade.pdf: 2400963 bytes, checksum: 99ec593844d6ba3a1107158d86656739 (MD5) / Made available in DSpace on 2017-01-21T11:09:00Z (GMT). No. of bitstreams: 2 license_rdf: 9 bytes, checksum: 42dd12a06de379d3ffa39b67dc9c7aff (MD5) glauber_antonio_reis_andrade.pdf: 2400963 bytes, checksum: 99ec593844d6ba3a1107158d86656739 (MD5) Previous issue date: 2016 / A Teofilina (TF), Clindamicina (CM), Varfarina (VF) e Verapamil (VP) s?o f?rmacos de baixo ?ndice terap?utico que necessitam de um controle de qualidade rigoroso na elabora??o de suas formula??es. O desenvolvimento de m?todos mais simples e r?pidos para doseamento desses medicamentos ? de grande interesse no setor farmac?utico. Neste sentido, o presente trabalho apresenta uma nova metodologia para determina??o desses f?rmacos por amperometria de m?ltiplos pulsos (MPA) acoplada ao sistema de an?lise por inje??o em batelada (BIA), utilizando o eletrodo de Diamante dopado com Boro (DDB). A an?lise em BIA foi realizada em uma c?lula eletroqu?mica do tipo Wall Jet, onde as inje??es foram realizadas por meio de uma micropipeta autom?tica ou, manualmente, por uma seringa descart?vel para TF, CM e VF, mostrando a possibilidade de diminuir custo do sistema de an?lise. O comportamento eletroqu?mico da TF, CM, VF e VP foi investigado por voltametria c?clica e os eletr?litos suportes escolhidos foram o ?cido sulf?rico 0,1 mol L-1, tamp?o fosfato 0,1 mol L-1 (pH 7,0), tamp?o fosfato 0,1 mol L-1 (pH 7,0) com 10% de ?lcool et?lico e ?cido sulf?rico 0,2 mol L-1, respectivamente. Nesses eletr?litos tr?s f?rmacos apresentaram um ?nico processo de oxida??o: a TF em +1,33V, a CM em +1,18 V e a VF em +0,90 V. J? o VP apresentou tr?s processos de oxida??o entre +1,2V e +1,5V, al?m de um processo de redu??o em +0,2V depende das oxida??es. A detec??o MPA-BIA foi baseada na aplica??o de um pulso de potencial de detec??o e outro de limpeza do DDB para tr?s f?rmacos. Neste caso, os pulsos de potencial para detec??o da TF, CM e VF foram todos aplicados por 100ms em +1,5V, +1,6V e +1,2V, respectivamente. Para determina??o do VP foram utilizados tr?s pulsos de potencial, um para oxida??o do VP (gerador) em +1,6V/50ms, um para redu??o do produto gerado (coletor) e quantifica??o do VP em -0,1V/30ms, e um terceiro em +1,1V/100ms para limpeza da superf?cie do DDB. A velocidade de inje??o da MA foi otimizada em 100?L s-1, exceto para VP que foi de 47?Ls-1, e com a SD a velocidade de inje??o foi de aproximadamente 107 ?Ls-1 pra a TF, CM e VF, proporcionando uma frequ?ncia anal?tica te?rica de pelo menos 53 determina??es por hora desses f?rmacos. Um baixo desvio padr?o relativo (10 medidas) foi obtido para todos os f?rmacos, n?o ultrapassando 3,0% tanto pela inje??o autom?tica quanto pela manual. As curvas anal?ticas foram estabelecidas e uma boa faixa linear foi obtida para todos os f?rmacos com pelo menos duas ordens de concentra??o. Os coeficientes de correla??o linear para todas as regress?es foram maiores que 0,992 em todos os estudos. Os estudos de adi??o e recupera??o mostraram valores pr?ximos a 100 % para todas as amostras farmac?uticas analisadas. O m?todo proposto usando a inje??o autom?tica e manual foi devidamente validado pelo m?todo oficial para cada um dos f?rmacos avaliados. Portanto, a detec??o MPA-BIA usando o eletrodo de DDB mostrou ser uma alternativa mais simples e r?pida para determina??o da TF, CM, VF e VP em formula??es farmac?uticas, possibilitando ainda uma diminui??o do custo do sistema BIA pela substitui??o da micropipeta autom?tica por uma seringa descart?vel. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Qu?mica, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2016. / Theophylline (TF), Clindamycin (CM), Warfarin (VF) and Verapamil (VP) are drugs of narrow therapeutic index that require a strict quality control in the preparation of their formulations. Thus, the development of simple and rapid methods for determination of these drugs is very important in the pharmaceutical industry. In this sense, this paper presents a new methodology for determination of these drugs by multiple-pulse amperometry (MPA) coupled to batch injection analysis (BIA), using the boron-doped diamond (BDD) electrode. The analysis in BIA system was performed in an electrochemical cell (Wall Jet), where the injections were performed by automatic micropipette or manually by an disposable syringe for TF, CM and VF, showing a possibility to reduction of the analysis cost. The electrochemical behavior of the analytes was investigated by cyclic voltammetry and the support electrolytes were chosen for TF, CM, VF and VP in medium of sulfuric acid 0.1 mol L-1, phosphate buffer 0.1 mol L-1 (pH 7.0), phosphate buffer 0.1 mol L-1 (pH 7.0) with 10% ethyl alcohol and sulfuric acid 0.2 mol L-1, respectively. In these conditions, three drugs exhibited a single oxidation process: TF in +1.33V, the CM in +1.18V and the VF in +0.90V (vs Ag/AgCl). Already the VP presented three oxidation processes between +1.2V and +1.5V, besides a reduction process in +0.20 V that depends on the oxidation. The MPA-BIA detection for three drugs (TF, CM, VF) was based on the application of two potential pulses, one for detection and other for cleaning BDD electrode. In this case, the potential pulses to detection the TF, CM and VF were all applied for 100ms at +1.5V, +1.2V and +1.6 V, respectively. In determination of the VP, were used three potential pulses, one for oxidation of VP (generator potential pulse) in +1.6V/50ms, one for reducing the generated product (collector potential pulse) and performed quantification of VP in -0.1V/30ms, and a third potential pulse at +1.1V/100ms for cleaning BDD electrode. The injection speed using automatic micropipette was 100?L s-1, except for VP that was 47?Ls-1, and injection speed by insulin syringe was approximately 107?Ls-1, which provide theoretical analytical frequency of at least 53 determinations per hour of these drugs. A low standard relative deviation (10 measures) was obtained for all drugs, not extending beyond 3.0% by both injections systems. The analytical curves were established and a good linear range was obtained for all drugs with at least two orders of concentration. The linear correlation coefficients for all regressions were higher than 0.992. The addition and recovery studies show values close to 100% for all drug samples analyzed. The proposed method using automatic and manual injection was validated by official method for each analyte. Therefore, this paper presented a fast and simple method for the determination of TF, CM, VF and VP in pharmaceutical formulations using BIA-MPA detection with BBD electrode. Moreover, this work demonstrated an inexpensive method for application in routine analysis of narrow therapeutic index drugs, mainly using a manual injection in BIA system by an disposable syringe.
50

Desenvolvimento de métodos eletroanalíticos empregando análise por injeção em batelada para a determinação de nafazolina, zinco, feniramina e clorfeniramina em formulações farmacêuticas

Oliveira, Thiago da Costa 24 July 2015 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / In this work we investigated the potentiality of batch injection analysis with square-wave voltammetry (BIA-SWV) detection for simultaneous determination of Zn and naphazoline (NAF) and batch injection analysis with multiple pulse amperometric (BIA-MPA) detection for simultaneous determination of NAF and pheniramine (FEN) or NAF and chlorpheniramine (CLO). In both methods, boron-doped diamond (BDD) was used as working electrode. For the simultaneous determination of Zn and NAF by BIA-SWV, the following conditions have been optimized: supporting electrolyte: acetate buffer 0.05 mol L-1 (pH = 4.7), injection volume: 100 μL, deposition time (Zn): 5 s, deposition potential (Zn) -1.5 V, : 100 s-1, a: 60 mV, ΔEs: 6 mV. Under these conditions, the method showed linear response range between 10 and 60 μmol L-1 for Zn (r = 0.992) and between 3.0 e 21 μmol L-1 for NAF (r = 0.999), high analytical frequency (70 injections h-1) and LOD of 0.126 μmol L-1 and 0.04 μmol L-1 for Zn and NAF, respectively. In the study of repeatability (n = 20), the calculated RSD were 0.98% and 0.97% for Zn and NAF, respectively. The simultaneous determination of NAF and FEN or NAF and CLO by BIA-MPA was performed with the application of three sequential pulses in function of time to the BDD electrode using Britton-Robinson Buffer solution 0.12 mol L-1 (pH = 10.0) as supporting electrolyte. At +1.1 V/50 ms, FEN or CLO was detected (oxidation) without interference of NAF. At +1.3 V/50 ms, both compounds (FEN + NAF or CLO + NAF) were oxidized. The current of NAF can then be obtained by subtraction of the currents detected during application of both potential pulses using a correction factor. The proposed method presented good ability (RSD = 1.7 and 4.0% for FEN and NAF; 2.1% and 3.6% for CLO and NAF, respectively; n=20); high analytical frequency (110 injections h-1), linear concentration range between 16 e 100 μmol L-1 for FEN and CLO (r > 0.996) and between 2 e 15 μmol L-1 for NAF (r > 0.997). The LOD calculated were 0.367, 0.361 e 0.148 μmol L-1, for FEN, CLO and NAF, respectively. The proposed methods were used for determination of these compounds in pharmaceutical samples. The obtained results were statistically similar to that obtained by HPLC (NAF, FEN and CLO) and atomic spectroscopy (Zn). / No presente trabalho investigou-se a potencialidade do sistema de análise por injeção em batelada com detecção por voltametria de onda quadrada (BIA-SWV) para determinação simultânea de Zn e nafazolina (NAF) e do sistema análise por injeção em batelada com detecção por amperometria de múltiplos pulsos (BIA-MPA) para determinação simultânea de NAF e feniramina (FEN) ou NAF e clorfeniramina (CLO). Em ambos os métodos, diamante dopado com boro (BDD) foi usado como eletrodo de trabalho. Para determinação simultânea de Zn e NAF empregando BIA-SWV, as seguintes condições foram otimizadas: eletrólito de suporte: tampão acetato 0,05 mol L-1 (pH = 4,7), volume de injeção: 100 μL, tempo de deposição (Zn): 5 s, potencial de deposição (Zn): -1,5 V, : 100 s-1, a: 60 mV, ΔEs: 6 mV. Nestas condições, o método apresentou faixa linear de resposta entre 10 e 60 μmol L-1 para Zn (r = 0,992) e entre 3,0 e 21 μmol L-1 para NAF (r = 0,999), frequência analítica de 70 injeções h-1 e limites de detecção de 0,126 μmol L-1e 0,04 μmol L-1 para Zn e NAF, respectivamente. No estudo de repetibilidade (n = 20), os DPRs foram calculados 0,98% e 0,97% para Zn e NAF, respectivamente. A determinação simultânea de NAF e FEN ou NAF e CLO por BIA-MPA foi realizada através da aplicação de dois pulsos de potenciais em função do tempo ao eletrodo de BDD usando tampão BR 0,12 mol L-1 (pH = 10) como eletrólito suporte. Em +1,1 V/50 ms, FEN ou CLO foram oxidadas livre da interferência de NAF. Em +1,3 V/50ms, ambos os compostos (NAF + FEN ou NAF + CLO) foram oxidados. A corrente proveniente da oxidação da NAF foi obtida pela subtração entre as correntes detectadas em ambos os pulsos de potenciais com auxílio de um fator de correção (FC). O método proposto apresentou boa estabilidade (DPR = 1,7 e 3,95% para FEN e NAF; 2,1 e 3,6% para CLO e NAF, respectivamente; n=20), alta frequência analítica (110 injeções h-1), faixa linear de resposta entre 16 e 100 μmol L-1 para FEN e CLO (r > 0,996) e entre 2 e 15 μmol L-1 para NAF (r > 0,997). Os limites de detecção foram de 0,367, 0,361 e 0,148 μmol L-1 para FEN, CLO e NAF, respectivamente. Os métodos propostos foram usados na determinação destes compostos em formulações farmacêuticas. Os resultados obtidos com os métodos propostos foram estatisticamente similares aos obtidos por HPLC (NAF, FEN e CLO) ou absorção atômica (Zn). / Mestre em Química

Page generated in 0.0435 seconds