• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1092
  • 13
  • 12
  • 12
  • 12
  • 10
  • 8
  • 6
  • 4
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 1125
  • 635
  • 284
  • 282
  • 275
  • 203
  • 170
  • 147
  • 146
  • 127
  • 114
  • 112
  • 108
  • 107
  • 104
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Associação entre restrição de sono e sobrepeso/obesidade entre crianças do sul do Brasil: estudo de uma coorte de nascimentos

Halal, Camila dos Santos El January 2014 (has links)
Made available in DSpace on 2014-09-13T02:01:01Z (GMT). No. of bitstreams: 1 000461279-Texto+Completo-0.pdf: 2459743 bytes, checksum: 9fa44daec31ee335a9623687951b34e0 (MD5) Previous issue date: 2014 / Introduction: Pediatric obesity has become a worldwide public health concern, with a perspective of an even greater increase over the next years, especially among developing countries. Overweight children are exposed from an early age to comorbidities and chronic pathologies that imply on an increase in morbimortality. Concomitantly, the general population, including children, has been sleeping gradatively less time. Studies have been searching for evidence linking sleep deprivation to overweight or obesity. Among pre-school children, this correlation is not well established. Objective: To evaluate the relation between sleep deprivation in the first years of life and overweight or obesity at 4 years of age. Materials and Methods: We used the data from the Pelotas, Brazil, 2004 birth Cohort, corresponding to perinatal, 12, 24 and 48 months follow-ups. On these moments, the child´s main caretaker responded to questions regarding sleep and feeding habits, as well as socioeconomic and demographic characteristics. Children who slept for less than 10 hours per night were considered sleep deprived. Children with a BMI Z-score 2 standard deviations above limits established by the World Health Organization were considered overweight, and those with a BMI Z-score above 3 standard deviations were considered obese. Results: Of the 4263 live births in Pelotas during the study year, 4231 were enrolled in the study. Of those, 94%, 93. 5% and 92% were re-evaluated on the 12, 24 and 48-month follow-ups, respectively. On the analysis stratified by age, only at 24 months we found a positive association between sleep deprivation and overweight at 48 months (PR 1,731. CI95% 1,246; 2,406. P=0,001). Analyzing the relation between sleep deprivation at any moment during the study period, we found that sleep-deprived children had a 27% higher chance of overweight/obesity at the end of the study (RP 1,267. CI 95% 0,989;1,624). This association was maintained after adjusting for possible confounders. Conclusion: On the studied population, children with sleep deprivation between 12 and 48 months of age showed a higher chance of being overweight or obese at 4 years. These findings show the importance of sleep quality and sleep hygiene in prevention and management of overweight and obesity in childhood. / Introdução: A obesidade infantil configura um problema de saúde pública a nível mundial, com uma perspectiva de aumento ainda mais significativo nos próximos anos, especialmente entre países em desenvolvimento. Crianças com sobrepeso são expostas desde muito cedo a comorbidades e patologias crônicas que implicam em aumento da morbimortalidade. Concomitantemente, as horas de sono da população em geral, inclusive crianças, vêm diminuindo de maneira gradativa. Estudos vêm buscando evidencias que conectem a redução do número de horas de sono noturno e obesidade. Entre crianças em idade pré-escolar, tal correlação ainda não está bem estabelecida. Objetivo: Avaliar e associação entre restrição de sono nos primeiros anos de vida e sobrepeso/obesidade aos 4 anos. Materiais e Métodos: Foi utilizado o banco de dados da Coorte de Nascimentos de 2004 da cidade de Pelotas, Brasil, correspondentes aos acompanhamentos perinatal, de 12, 24 e 48 meses. Nesses momentos, o principal cuidador da criança respondeu perguntas a respeito de hábitos de sono, alimentares e sobre características demográficas e socioeconômicas. Consideraram-se restritas em sono as crianças que dormiam em média menos de 10 horas por noite. Consideraram-se com sobrepeso as crianças com escore-Z para IMC a partir de 2 desvios-padrões da média estabelecida pela Organização Mundial de Saúde, e obesos os com a partir de 3 desvios-padrão. Resultados: Dentre os 4. 263 nascidos-vivos daquela cidade, 4. 231 foram inscritos no estudo ainda no período perinatal. Deste total, permaneceram em acompanhamento nos seguimentos de 12, 24 e 48 meses, respectivamente, 94%, 93,5% e 92%. Nas análises por faixa etária, somente aos 24 meses houve associação significativa entre restrição de sono e sobrepeso/obesidade aos 48 meses (PR 1,731. CI95% 1,246; 2,406. P=0,001). Avaliando-se a associação entre restrição de sono em algum momento durante o período acompanhamento e sobrepeso/obesidade aos 48 meses, encontrou-se que os restritos em sono tiveram uma chance 27% maior (RP 1,267. CI 95% 0,989;1,624) de alterações de peso ao final do acompanhamento. Essa associação se manteve após ajuste para potenciais fatores de confusão. Conclusão: Na população estudada, crianças com restrição de sono entre 12 e 48 meses apresentaram maior chance de sobrepeso/obesidade aos 48 meses. Estes achados chamam a atenção para a importância da qualidade do sono e da implantação de higiene do sono na prevenção e manejo de sobrepeso e obesidade na infância.
172

Avaliação da via aérea faringiana com uso de dispositivo de avanço mandibular em pacientes com apnéia obstrutiva do sono: análise dos resultados por exames de imagem e polissonografia

Woltmann, Marcus January 2014 (has links)
Made available in DSpace on 2014-09-20T02:01:34Z (GMT). No. of bitstreams: 1 000461460-Texto+Completo-0.pdf: 3408472 bytes, checksum: 83ab10ad1632af7f932c8259fd899ec5 (MD5) Previous issue date: 2014 / Purpose: The pharyngeal airway may change after mandibular advancement in patient using intraoral device in obstructive sleep apnea (OSA) treatment. The aim of this study was to evaluate the dimensional and volumetric changes of superior airway promoted by an adjustable mandibular advancement device (AMAD) and the polysomnographic results in patients with OSA facial pattern facial Cl II.Materials and Methods: The present prospective study selected 11 patients with OSA (5 males and 6 females) and radiographs and ct scans, and polysomnographic exam were performed with and without the use of AMAD. The airway was assessed in the following aspects: superior pharyngeal space (S1), posterior palatal space (S2), median pharyngeal space (S3), posterior pharyngeal space (S4), inferior pharyngeal space (S5), pharyngeal volume (CT1), anterior-posterior lengths of the smallest cross-sectional area (CT2), lateral lengths of smallest cross-sectional area (CT3), pharyngeal smallest cross-section area (CT4). The analyzed variables of the polysomnographic data were: AH total (total number of apnea and hypopnea), AHI (apnea and hypopnea index - calculated as the average number of respiratory events per hour of sleep); AI (Apnea index), HI (Hypopnea index), Apnea duration, Hypopnea duration, Lowest O2% saturation.Results: The use of the AMAD induced an insignificant decrease of the pharyngeal airway as observed in the S1 (20. 091 to 20. 01mm decrease of -0,26%) and S4 (11. 08 to 10. 59mm decrease of -4. 2%). A not statistically significant increase was observed in S2 (8. 33 to 9. 43mm increase of 13. 67%), S3 (18. 23 to 18. 34mm increase of 1,2%) and CT1 (13393 to 15948 mm3 increase of 19,07%). Statistically significant increases were observed in S5 (11. 92 to 15. 67mm increase of 47. 08%), CT2 (media of 5. 81 to 7,71mm increase of 32,7%), CT3 (17,3 mm to 22,33 mm increase of 29. 07%) and CT4 (79,77 to 119,38 mm2 increase of 49. 65%), and determined a significant decrease of the variables total AH (159,9 to 54,8 reduction of 34,27%), AHI (21,57 to 7,54 decrease of 34. 95%) and AI (17,33 to 3,99 reduction 23,1%). A nonsignificant reduction in the duration of apnea (16,4 to 14,7 reduction of 10. 36%), Hypopnea (18. 42 to 16,94 reduction of 8. 03%). A nonsignificant increase of HI (3. 26 to 3. 29 increase of 0. 92%), Lowest O2% saturation (76. 6 to 82. 9 increase of 8. 22%).Conclusions: A correlation between the mandibular advancement and changes in the measurements of pharyngeal airway were significant with the use of AMAD in the inferior pharyngeal space (S5), anterior posterior lengths of smallest pharyngeal cross-sectional area (CT2), lateral lengths of smallest pharyngeal cross-sectional area (CT3), and pharyngeal smallest cross-section area (CT4), and polysomnographic data showed a significant improvement with the reduction of the variables AH total, AHI, HI. Results showed that the use of the AMAD allows an increase of the superior airway and improves important variables of the polysomnography exam, being the lateral teleradiography, CT scan and polysomnography are effective methods for the diagnosis and evaluation of the treatment’s progress. / Objetivo: A via aérea faringiana pode mudar após o avanço mandibular promovido por aparelhos intra-orais para o tratamento de apnéia obstrutiva do sono (OSA). O objetivo deste estudo foi avaliar as alterações dimensionais e volumétricas da via aérea superior promovida pelo o uso de um aparelho intra-oral ajustável de avanço mandibular (AMAD) bem como os resultados polissonograficos em pacientes com OSA padrão facial Cl II.Materiais e Métodos: O estudo prospectivo selecionou 11 pacientes (5 homens e 6 mulheres) sendo realizados telerradiografias de perfil, tomografias computadorizadas, e exame polissonografico com e sem o uso do AMAD. A via aérea foi avaliada nos seguintes aspectos: espaço faringeano superior (S1), espaço palatal posterior (S2), espaço faringiano médio (S3), espaço faringiano posterior (S4), espaço faringiano inferior (S5), volume faringiano (CT1), diâmetro antero-posterior da menor área de secção faringeana (CT2), dimensão lateral da menor área de secção faríngea (CT3), área de menor secção faringiana transversal (CT4), e os exames polissonográficos foram avaliados as variáveis AH total (numero total de apnéias e hipoapnéias), AHI (índice de apnéia e hipoapnéia), AI (índice de apnéia), HI (índice de hipoapnéia), duração de apnéia, duração de hipoapnéia, menor saturação O2%.Resultados: O uso do AMAD gerou uma redução da via aérea faringiana não significativa observada em S1 (20. 091 para 20. 01mm - diminuição de -0,26%) e S4 (11. 08 para 10. 59mm - diminuição de -4. 2%). Um aumento estatisticamente não significante foi observado em S2 (8. 33 para 9. 43mm - aumento de 13. 67%), S3 (18. 23 para 18. 34mm - aumento de 1. 2%) e CT1 (13393 para 15948 mm3 aumento de 19. 07%). Um aumento estatisticamente significante foi observado em S5 (11. 92 para 15. 67mm – aumento de 47. 08%), CT2 (5. 81 para 7. 71mm – aumento de 32. 7%), CT3 (17,3 mm para 22,33mm - aumento de 29. 07%) e CT4 (79,77 para 119,38 mm2 – aumento de 49. 65%), e determinou uma diminuição significativa das variáveis AH total (159. 9 para 54. 8 redução de 34. 27%), AHI (21. 57 para 7. 54 redução de 34. 95%) e Al (17. 33 para 3. 99 redução de 23. 1%). Uma redução não significativa da duração de apnéia (16,4 para 14,7 redução de 10,36%), hipoapnéia (18,42 para 16,94 redução de 8,03%). Um aumento não significativo do HI (3,26 para 3,29 aumento de 0,92%), menor saturação de O2% (76,6 para 82,9 aumento de 8,22%).Conclusões: A relação entre o movimento de avanço mandibular e as alterações das medidas da via aérea faringiana foram observadas de forma significativa com o uso do AMAD nos espaço faringiano inferior (S5), dimensão antero-posterior da área de menor secção transversa da faringe (CT2), dimensão lateral da área de menor secção transversa da faringe (CT3), e área de menor seccão transversa (CT4), bem como os dados polissonográficos demonstraram uma melhora significativa com a redução das variáveis AH total, AHI, e HI. Os resultados demonstraram que o uso do AMAD promove um aumento da via aérea superior e melhora variáveis importantes do exame polissonográfico, sendo a a teleradiografia lateral, tomografia computadorizada e a polissonografia métodos eficazes para o diagnóstico e evolução do progresso dos tratamentos.
173

Melhora do metaborreflexo periférico após cirurgia bariátrica

Silva, Roberto Pacheco da January 2012 (has links)
Resumo não disponível
174

Alterações hipocampais em camundongos submetidos a um modelo experimental de apneia do sono

Cruz, Dennis Baroni January 2013 (has links)
Introdução: A apneia obstrutiva do sono (AOS) ocasiona a hipóxia intermitente (HI), causando doenças cardíacas, vasculares e neurológicas. O modelo de experimentação animal utiliza a HI para simular a AOS, permitindo a avaliação das alterações encefálicas, sendo o hipocampo uma área reconhecidamente influenciada pela hipóxia. A S100B é uma proteína de 21-kDa ligada ao cálcio, produzida e liberada principalmente pelos astrócitos no neurópilo do sistema nervoso central. Sua dosagem tem sido utilizada para compreender o envolvimento de distintos tipos celulares em determinadas condições patológicas. O presente estudo objetiva testar a hipótese de que a HI empregada em um modelo experimental de AOS em camundongos é capaz de alterar o número de astrócitos em diferentes subcamadas hipocampais (CA1, CA3 e DG), além de modificar qualitativamente a reatividade imuno-histoquímica destas células ao S100B. Materiais e Métodos: Camundongos CF-1 foram expostos ou a 35 dias de HI (n = 27) ou a HIS (n = 27), alternando 30 segundos de hipóxia progressiva a um nadir de 7%, seguidos por 30 segundos de normóxia. Durante 8 horas, os animais sofreram um total de 480 ciclos de hipóxia/reoxigenação, equivalente a um índice de apneia de 60/hora. O encéfalo foi dissecado, sendo o hipocampo e suas subcamadas analisados histologicamente pela técnica de imuno-histoquímica com a utilização do anticorpo S100B. Resultados: Foi realizada a análise quantitativa dos astrócitos hipocampais imunorreagentes ao S100B. A média desta foi de 23,85 ± 0,37 astrócitos/0,25 mm2 no grupo HI, enquanto no grupo HIS foi de 21,03 ± 0,50 astrócitos/0,25 mm2 (p < 0,001). Esta diferença também foi também observada de forma global nas subcamadas CA1 e CA3, sendo menos perceptível no DG. A imunorreatividade astrocitária foi maior (+++) no grupo HI, não atingindo tal intensidade no grupo HIS. A análise qualitativa secundária evidenciou a presença de cariorrexe, de picnose neuronal, além de corpos celulares astrocitários discretamente hipertróficos apenas nos animais do grupo HI. Conclusão: A HI aumentou a densidade numérica de astrócitos hipocampais, assim como a imunorreatividade destas células ao S100B, no processo chamado de astrogliose reativa. Alterações neuronais secundárias também foram observadas no grupo HI. Investigações futuras utilizando outras metodologias permitirão uma melhor avaliação dos resultados aqui descritos. / Introduction: Obstructive sleep apnea (OSA) causes intermittent hypoxia (IH), leading to cardiovascular and neurological diseases. The animal experimental studies use IH to simulate OSA, enabling the analysis of brain alterations, with the hippocampus recognized as an area influenced by hypoxia. S100B is a 21-kDa protein bonded to calcium, produced and secreted primarily by astrocytes in the neutrophil of the central nervous system. Levels of the protein have been used to understand the involvement of different cell types in certain pathological conditions. The present study aimed to test the hypothesis that IH used in an experimental design investigating OSA in mice can alter the number of astrocytes in different hippocampal sublayers (CA1, CA3 and dentate gyrus), in addition to quantitatively modifying the immunohistochemical reactivity of these cells. Materials and Methods: CF-1 mice were exposed to 35 days of either IH (n = 27) or SIH (n = 27), alternating 30 seconds of progressive hypoxia with a nadir of 7%, followed by 30 seconds of normoxia. Over a period of 8 hours, the animals were submitted to a total of 48 hypoxia/reoxygenation cycles, equivalent to an apnea index of 60/hour. The brain was dissected and the hippocampus and its sublayers were histologically analyzed by immunohistochemistry using S100B antibodies. Results: A quantitative analysis was performed of hippocampal astrocytes immunoreactive to S100B. The means recorded were 23.85 ± 0.37 astrocytes/0.25 mm2 and 21.03 ± 0.50 astrocytes/0.25 mm2 (p < 0.001) in the IH and SIH (simulated intermittent hypoxia) groups, respectively. This difference was also observed in sublayers CA1 and CA3 overall, and was less noticeable in the dentate gyrus. Astrocyte immunoreactivity was greater (+++) in the IH group and did not achieve this intensity in the SIH group. Secondary qualitative analysis revealed the presence of karyorrhexis, pyknotic neurons, and discretely hypertrophic astrocytes only in animals from the IH group. Conclusion: IH increased the number density of hippocampal astrocytes, as well as their immunoreactivity to S100B, in a process known as reactive astrogliosis. Secondary neuron alterations were also observed in the IH group. Future investigations using alternative methodologies would allow a better assessment of the results described here.
175

Alterações encefálicas causadas pela hipóxia intermitente em modelo animal de apneia do sono

Baronio, Diego Moura January 2012 (has links)
Introdução Pacientes com apneia obstrutiva do sono exibem alterações morfológicas encefálicas. A hipóxia intermitente causa morte celular em 90% dos neurônios de Purkinje. Aquaporinas são proteínas de membrana que formam canais de água. O conhecimento do papel das aquaporinas nas alterações encefálicas causadas pela apneia obstrutiva do sono é limitado. Objetivos Avaliar o efeito da hipóxia intermitente isocápnica nas aquaporinas e no dano celular em diferentes tecidos de camundongos C57/bl. Métodos Conteúdo cerebral de água e expressão de aquaporinas 1, 3, 4, 9, e HIF-1a foram medidos. Realizou-se coloração com hematoxilina-eosina e marcação por imunohistoquímica, além de técnicas de Western blot e ELISA. Resultados Os níveis de HIF-1a no córtex frontal foram maiores no grupo exposto a hipóxia intermitente isocápnica do que no grupo controle, confirmando hipóxia efetiva. O peso molhado e o conteúdo de água do encéfalo foram maiores no grupo hipóxia. Os níveis cerebelares de aquaporina 1 foram menores no grupo hipóxia. Os níveis de aquaporina 3 no hipocampo e pele foram similares em ambos os grupos. Aquaporina 4 no córtex frontal foi mais expressa no grupo hipóxia. Aquaporina 9 apresentou maiores níveis no córtex frontal e estriado do grupo hipóxia. Observou-se dano celular em 88% das células de Purkinje no grupo hipóxia. A marcação de S100B no cerebelo de grupo hipóxia foi mais evidente do que nos controles. Conclusão Exposição crônica a hipóxia simulando apneia do sono causa edema encefálico e altera a concentração de aquaporinas. Alterações em proteínas de canal de água podem estar envolvidas no mecanismo do dano observado em estruturas cerebrais na apneia obstrutiva do sono. / Background Patients with obstructive sleep apnea exhibit cerebral morphological changes. The damaging effect of intermittent hypoxia was already demonstrated in a study where mice exposed to this condition had 90% of degeneration of Purkinje cells. Aquaporins are membrane proteins responsible for the transport and the balance of water content in the brain. Little attention has been dedicated to the role of aquaporins in sleep apnea-related brain alterations. Objectives To evaluate the effect of isocapnic intermittent hypoxia on water-transport proteins and cellular damage in different tissues of C57/bl mice. Methods Brain water content, aquaporins 1, 3, 4, 9, and HIF-1a were measured. Staining with hematoxylin-eosin and immunohistochemistry were performed. Results HIF-1a expression in the frontal cortex was higher in the exposed than in the sham group, confirming effective hypoxia. The brain wet weight and brain water content were higher in the hypoxia group. Cerebellar Aquaporin-1 levels were lower in the hypoxia group. Aquaporin 3 levels in hippocampus and skin were similar in both groups. Aquaporin 4 expression in the frontal cortex was higher in the hypoxia group. Aquaporin 9 expression of the hypoxia group was greater in the cortex and striatum. Death rate of Purkinje cells in the hypoxia group was 88%. Stronger immunoreactivity to S100B was detected in the hypoxia group. Conclusions Chronic exposure to hypoxia simulating sleep apnea causes brain edema and alters the concentration of aquaporins. Water channel proteins are possibly implicated in the cellular damage to brain structures seen in obstructive sleep apnea.
176

O impacto da apneia do sono na aptidão física de idosos

Pedroso, Martina Madalena January 2015 (has links)
Resumo não disponível
177

Pressão arterial em idosos com apneia do sono

Fagundes, Micheli January 2016 (has links)
Introdução: Apneia obstrutiva do sono (AOS) e hipertensão arterial podem ter mecanismos fisiopatológicos comuns. AOS leva à hiperatividade simpática, stress oxidativo e lesão endotelial, o que pode contribuir para a severidade da hipertensão. Trabalhamos com a hipótese de que os indivíduos idosos com AOS mais grave são mais propensos a ter hipertensão não controlada. Métodos: Idosos de 65 a 80 anos fisicamente independentes, de ambos os sexos foram incluídos. Eles foram submetidos à polissonografia portátil e a monitorização ambulatorial da pressão arterial (MAPA). A pressão arterial de 24 horas > 130/85 mm Hg foi considerada como hipertensão não controlada. Indivíduos sem hipertensão ou com hipertensão não tratada foram incluídos como controles. Resultados: Um total de 143 indivíduos, com idades entre 70±4 anos, 54% do sexo masculino, 33% obesos e 10% cor não-branca foram incluídos no presente estudo. Na amostra, 17% eram normotensos, 10% hipertensos não medicados, 34% com hipertensão controlada e 39% com hipertensão não controlada. O índice de apneia e hipopneia (IAH) foi maior no grupo de hipertensos não controlado do que nos outros grupos (P = 0,04). No modelo de regressão logística binária, a presença de hipertensão não controlada aumenta três vezes as chances de IAH>15, ou seja, AOS moderada a grave. O modelo que explica cerca de 14% da variância inclui também os fatores de confusão clássicos da AOS, sexo, idade, obesidade e etnia. Conclusão: Apneia obstrutiva do sono continua sendo uma causa negligenciada de hipertensão em idosos. Os resultados do presente estudo devem ser uma chamada à ação. Considerar AOS como uma causa comum de hipertensão não controlada pode salvar-vidas, considerando que hipertensão é a principal causa de doença cardiovascular e mortalidade.
178

Examinando os mecanismos de perda de peso em modelo animal de apneia do sono

Fiori, Cintia Zappe January 2011 (has links)
Objetivo: Testar a hipótese de que a perda de peso no modelo de hipóxia intermitente isocápnica (hipóxia) de apneia do sono altera a fisiologia do tecido adiposo branco e marrom, particularmente, leptina, adiponectina e proteína desacopladora 1 (UCP-1). Desenho e Intervenção: Camundongos Balb/c foram expostos à hipóxia intermitente ou à hipóxia intermitente simulada. Durante oito horas por dia, o sistema de hipóxia alterna 30 segundos de inalação de O2 a 9%±1, com 30 segundos de normóxia (O2 a 21%). Avaliações e Resultados: Após 37 dias, o tecido adiposo marrom (TAM) dissecado e imediatamente congelado. A expressão do mRNA da proteína desacopladora 1 (UCP-1) do TAM foi mensurada por PCR em tempo real. Os níveis séricos de adiponectina, leptina e cortisol foram quantificados por ELISA. O grupo hipóxia consumiu significativamente menos ração comparado ao grupo hipóxia simulada e ganhou significativamente menos peso corporal. Observação microscópica e mensuração do tamanho celular demonstraram diminuição significativa no tamanho dos adipócitos branco e marrom. Os níveis de leptina e cortisol não sofreram alterações significativas entre os grupos. No grupo hipóxia os níveis de adiponectina foram significativamente menores (84,33±6.2 pg/mL) comparado ao grupo simulada (116,85±12 pg/mL; P=0,02). Mediana da expressão do mRNA da UCP-1 nos grupos hipóxia e simulada foram respectivamente, 0,0007 [0,0002-0,66] e 1,33 [0,49-11,94] (P=0,006). Conclusão: Modelo de hipóxia intermitente de apneia do sono reduz a ingestão alimentar, o ganho de peso, os níveis de adiponectina e as expressão do mRNA da UCP- 1. Estes resultados originais estão em contraste com o aumento da propensão para a obesidade em pacientes com apneia e gera a hipótese do papel da hipóxia intermitente na supressão da atividade do BAT observado em indivíduos com obesidade.
179

Monitorização ambulatorial intensiva da pressão arterial e polissonografia em indivíduos com apneia do sono

Rahmeier, Laura January 2011 (has links)
Introdução: Estudos têm mostrado que a pressão arterial noturna é um parâmetro importante no prognóstico cardiovascular. Desta forma não têm sido adequadamente comparadas às médias pressóricas nas diferentes incidências do sono. Objetivos: Investigar as médias pressóricas nas diferentes incidências que ocorrem durante o período de sono em indivíduos com síndrome da apneia obstrutiva do sono. Métodos: Recrutaram-se 16 pacientes, 13 homens, todos com suspeita de apneia do sono, que realizaram polissonografia diagnóstica e que concordaram em participar do estudo, usando monitor ambulatorial de pressão arterial (Spacelasbs 90207) durante exame do sono. Um microfone foi acoplado ao monitor da pressão arterial para registrar os sons da atividade do monitor e permitir classificar cada medida da monitorização da pressão arterial durante o acordar ou sono eletrograficamente determinado. Comparou-se a pressão arterial sistólica e (PAS) e pressão arterial diastólica (PAD) nos estágios acordado, despertar e sono REM. Resultados: A idade foi de 38±11 anos, índice de massa corporal (IMC) 32±8 kg/m2, índice de apneia-hipopneia (IAH) 28±34 AH/hora. Não houve diferença significativa na PAS e PAD quando comparados apenas os períodos de maior atividade simpática. Quando se comparou o período de despertares e dormindo (maior e menor atividade simpática, respectivamente) encontrou-se diferença significativa na PAD (84,2±12,4 mmHg versus78,8±13; P=0,035). Houve uma tendência a significância em relação à PAS (147,9±10,4 mmHg versus 140,7±18,2 mmHg; P=0,095). Conclusão: O período de sono é constituído de diferentes estágios que podem apresentar diferenças significativas na pressão arterial sistólica e diastólica. Este achado poderia ter implicação na avaliação mais detalhada da influência da pressão arterial noturna sobre o prognóstico cardiovascular abrindo-se novas intervenções terapêuticas considerando-se, não o sono como um todo, mas sim suas diferentes fases e intercorrências.
180

Detecção automática de eventos relacionados à síndrome da apneia-hipopneia de sono / Automatic detection of events related to the syndrome apnea - hipopnea of the dream / Detección automática de eventos relacionados al síndrome de apnea-hipopnea de sueño

Obando Gomez, Libardo Edmundo 12 1900 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2012. / Submitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2013-03-19T13:15:48Z No. of bitstreams: 1 2012_LibardoEdmundoObandoGomez.pdf: 4021236 bytes, checksum: c45fd336114fc1e45ddcf94bb24f4018 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-03-21T13:02:27Z (GMT) No. of bitstreams: 1 2012_LibardoEdmundoObandoGomez.pdf: 4021236 bytes, checksum: c45fd336114fc1e45ddcf94bb24f4018 (MD5) / Made available in DSpace on 2013-03-21T13:02:27Z (GMT). No. of bitstreams: 1 2012_LibardoEdmundoObandoGomez.pdf: 4021236 bytes, checksum: c45fd336114fc1e45ddcf94bb24f4018 (MD5) / Nos últimos anos, os distúrbios respiratórios – principalmente apneia e hipopneia do sono – têm gerado crescente interesse tanto na comunidade médica como na sociedade, posto que há evidências de que a Síndrome de Apneia e Hipopneia do Sono (SAHS) é uma doença de saúde publica altamente prevalente, com manifestações clínicas específicas e alto impacto sobre a saúde e bem-estar físico, psicológica e mental. Em todo o mundo tem-se procurado diferentes alternativas diagnósticas ao exame de polissonográfia convencional noturna (PSG), que embora seja considerado como o teste de escolha e referência, não é livre de problemas – além de ser caro,demorado, de alta complexidade e baixo acesso. Este trabalho apresenta o desenvolvimento de dois algoritmos – em amplitude (AMP) e energia (ENG) – para a detecção e cálculo de eventos respiratórios associados com SAHS, como uma ferramenta para automatizar a detecção manual atualmente realizada na maioria dos centros de polissonográfia. Utilizando apenas dois sinais fisiológicos – saturação de oxigênio e fluxo de ar – para reduzir a quantidade de sinais usados em sistemas convencionais de diagnóstico de eventos respiratórios. Utilizou-se uma base de dados com seis gravações de registros polissonográficos e eletromiográficos (Apnea-ECG database)disponibilizadas gratuitamente por Physionet, abrangendo indivíduos saudáveis ou com apneia- hipopneia em diferentes graus de severidade, para validar os algoritmos. As detecções são calculadas tendo em conta os atuais critérios clínicos da Associação Americana de Medicina do Sono (AASM), cada tipo de evento (apneia e hipopneia) em registos (épocas) de um minuto e quatro modelos de implementação com características de processamento diferentes (varredura única e dupla com janela fixa ou ajustável). Os algoritmos foram analisados a partir de seus verdadeiros e falsos positivos e negativos (VP, FP, VN, FN); sensibilidade (Se), especificidade (Es) e exatidão (E). A análise estatística foi feita com teste ANOVA 2-vias com medidas repetidas e testes post-hoc, Chi-quadrado ou Teste Exato de Fisher, conforme apropriado. Resultados considerados significativos para p≤0,05. A análise ANOVA demonstrou que a sensibilidade depende significativamente da varredura (AMP, p=0,0037; ENG, p=0,004), janela (AMP, p=0,027; ENG, p=0,1248), da interação entre estes fatores (AMP, p=0,0051; ENG, p=0,0294) e do pareamento (AMP, p=0,0005; ENG, p=0,0019). Resultados semelhantes foram encontrados para exatidão, salvo que esta não é afetada pelo tipo de janela (AMP, p=0,0611; ENG, p=0,1971): varredura (AMP, p=0,0342; ENG, p=0,0354); pareamento (AMP, p<0,0001; ENG, p=0,0004); interação (AMP, p=0,0112; ENG, p=0,0497). Variações de especificidade foram estatisticamente não significativas sob todos os aspectos. Foram obtidos, em média±DP, os valores de (Se) 82±9,4%, (Es) 85±13% e 83±8,5% (E) – compatíveis com outros trabalhos da literatura. Os arquivos A01R, A02R, A04R apresentaram variações significativas de VP (AMP, p=0,0298; p=0,0079; p=0,0238, respectivamente; ENG, p=0,00298; p=0,05; p=0,2294, respectivamente) e FN (AMP, P=0,00015; p=4,43.10-6 ; p=4,38.10-6 , respectivamente; ENG, p=7,45.10-12 ; p=0,0627; p=0,0811, respectivamente). FP e VN não variaram significativamente em nenhum dos seis registros. Os resultados mostraram que o algoritmo de amplitude com varredura dupla e janela fixa teve o melhor desempenho na detecção conforme critérios da AASM. Trabalhos futuros indicam uma possível ferramenta de triagem diagnóstica, de baixo custo e alta funcionalidade para SAHS. _______________________________________________________________________________________ ABSTRACT / In the last years the respiratory disorders and specially Apnea- Hypopnea’s Syndrome of Dream (SAHS), they have gone generated an increasing interest in the medical community as in the society, since to demonstrated that the (SAHS), it is a disease of health it publishes very prevalent, with clinical manifestations you specify, that it needs of the doctor to identify and to provide suitable and opportune treatment, due to his impact in the health, physical, psychological and mental well-being, which spoils the quality of life and survival of the persons who suffer it. This because in the available units of dream in hospitals and institutions of health for the diagnosis and analysis from disturbance, they are insufficient in number and in equipment for attender the increasing demand, giving origin to extensive lists of waits, in often with one or more years before to realize an examination of dream. In the whole world there has looked for different diagnostic alternatives to the examination of polisomnografia conventional night (PSG), which now is considered to be the examination of choice and reference, though it is not free of disadvantages since beside being of high cost, delayed and high complexity is available in few centers. This work presents the development of two algorithms: extent (AMP) and energy (ENG) for the detection and calculation of the respiratory events associated with (SAHS), as a tool to automate the manual form of detection that nowadays one comes handling in the majority of the centers polisomnograficos. Using two physiological signs saturation of oxygen and air flow, to reduce the quantity of signs used in the conventional systems to diagnose events (of apneas and hypopneas), with 6 recordings records polisomnograficos and electromiograficos (Apnea-ECG database) available free for Physionet, covering healthy individuals and with syndrome of apnea - hypopnea of the dream in varied degrees of severity, to validate the algorithms. The detections are calculated bearing in mind; the clinical criteria associated with the American Academy Medicine of Dream (AASM), every type of event (apnea and hipopnea), registers in time of a minute and 4 models of implementation with different characteristics from processing (the only and double sweep with sales fixes and adjustable). The algorithms were analyzed from his real and false positives and negatives (VP, FP, VN, FN); sensibility (Se), specificity (Es) and accuracy (E). The statistical analysis was realized by the Test ANOVA 2 routes com measures repeated and it tries post-hoc, Chi-cuadrado o Tests Exact de Fisher, as it was appropriate. Considered results significations for p=0,05. The analysis of ANOVA depositor that the sensibility depends significantly on the sweep (AMP, p=0, 0037; ENG, p=0,004), window (AMP, p=0,027; ENG, p=0,1248), of the interaction between these factors (AMP, p=0,0051; ENG, p=0,0294) and fitting (AMP, p=0,0005; ENG, p=0,0019). Similar results were found for accuracy, except that this one does not fall ill for the type of window (AMP, p=0,0611; ENG, p=0,1971): window (AMP, p=0,0342; ENG, p=0,0354); fitting (AMP, p <0,0001; ENG, p=0,0004); interaction (AMP, p=0,0112; ENG, p=0,0497). Variations of specificity were statistically not significant in all you aspects. There were obtained, in media ±DP, the values of 82±9, 4 % (Se), 85±13 % (Es) and 83±8,5 % (E) - compatible com other works of the literature. The files A01R, A02R, A04R were presenting significant variations of the VP (AMP, p=0,0298; p=0,0079; p=0,0238, respectively; ENG, p=0,00298; p=0,05; p=0,2294, respectively) and FN (AMP, P=0,00015; p=4,43.10-6 ; p=4,38.10-6, respectively; ENG, p=7,45.10-12; p=0,0627; p=0,0811, respectively). FP and VN were they were not changing significantly in any of 6 records. The results showed that the algorithm of extent like double sweep and fixed window had the best performance in the detections similar the criteria of the (AASM). Future works indicate a possible tool of diagnostic work, of low cost and high functionality for (SAHS). _______________________________________________________________________________________ RESUMEN / En los ultimo años los trastornos respiratorios y especialmente el Síndrome de Apnea-Hipopnea de Sueño (SAHS), han ido generado un interés creciente en la comunidad médica como en la sociedad, ya que se a evidenciado que el SAHS, es una enfermedad de salud publica muy prevalente, con manifestaciones clinicas especificas, que requiere del medico para identificar y proporcionar tratamiento adecuado e oportuno, debido a su impacto en saldud y en el bienestar fisico, psicologico y mental, que deteriora la cualidad de vida y sobrevida de las personas que lo padecen. En todo el mundo se han buscado diferentes alternativas diagnosticas al examene de polisomnografia convencional norcturna (PSG), que ahora sea considerada como el examen de eleccion y referencia, no es libre de problemas, ademas de ser caro, demorado de alta complejidad y disponible en pocos centros. Este trabajo presenta el desarrollo de dos algoritmo amplitud (AMP) y energia (ENG) para la deteccion y calculo de los eventos respiratorios asociados a SAHS, como una herramienta para automatizar la forma manual de detección que hoy en dia se viene manejando en la mayoria de los centros polisomnografícos. Usando apenas dos señales fisiologicas saturación de oxigeno y flujo de aire, para reducir la cantidad de señales utilizadas en los sistemas convencionales para diagnosticar eventos (de apneas y hipopneas), con 6 grabaciones de registros polisomnograficos y electromiograficos (Apnea-ECG database) disponiblilizados gratuitamente por Physionet, cubriendo individuos saludables y con síndrome de apnea- hipopnea del sueño en grados variados de severidad, para validar los algoritmos. Las detecciones son calculadas teniendo en cuenta; los criterios clinicos asociados a Academia Americana Medicina de Sueño (AASM), cada tipo de evento (apnea y hipopnea), en registros (épocas) de un minuto y 4 modelos de implementacion con caracteristicas de procesamiento diferentes (barrido unico y doble con ventas fija y ajustable). Los algoritmos fueron analizados a partir de sus verdaderos y falsos positivos y negativos (VP, FP, VN, FN); sensibilidad (Se), especificidad (Es) y exactitud (E). el analisis estadistico fue realizado con la prueba ANOVA 2 vias con medidas repetidas y prueba post-hoc, Chi-quadrado y Teste Exato de Fisher, conforme es apropriado. Resultados considerados signifcativos para p≤0,05. El análisis de ANOVA demostro que la sensibilidad depende significativamente del barrido (AMP, p=0,0037; ENG, p=0,004), ventana (AMP, p=0,027; ENG, p=0,1248), de la interaccion entre estos factores (AMP, p=0,0051; ENG, p=0,0294) y emparejamiento (AMP, p=0,0005; ENG, p=0,0019). Resultados semejantes fueron encontrados para exactitud, salvo que está no es afetada por el tipo de ventana (AMP, p=0,0611; ENG,p=0,1971): ventana (AMP, p=0,0342; ENG, p=0,0354); emparejamiento (AMP, p<0,0001; ENG, p=0,0004); interaccion (AMP, p=0,0112; ENG, p=0,0497). Variaciones de especificidad fueron estadisticamente no significativas en todos os aspectos. Fueron obtenidos, en média±DP, los valores de 82±9,4% (Se), 85±13% (Es) e 83±8,5% (E) – compatibles con otros trabajos de la literatura. Los arquivos A01R, A02R, A04R presentaran variaciones significativas de VP (AMP, p=0,0298; p=0,0079; p=0,0238, respectivamente; ENG, p=0,00298; p=0,05; p=0,2294, respectivamente) e FN (AMP, P=0,00015; p=4,43.10-6; p=4,38.10-6, respectivamente; ENG, p=7,45.10-12 ; p=0,0627; p=0,0811, respectivamente). FP e VN no variaran significativamente em ningun de las 6 registros. Los resultados mostraron que el algoritmo de amplitud con barrido doble y ventana fija tuvo el mejor desempeño en las detecciones conforme los criterios de la AASM. Trabajos futuros indican una posible herramienta de triage diagnostico, de bajo costo y alta funcionalidad para SAHS.

Page generated in 0.1057 seconds