• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 308
  • 18
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 327
  • 168
  • 87
  • 83
  • 82
  • 66
  • 63
  • 58
  • 57
  • 41
  • 39
  • 33
  • 30
  • 25
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Monitorização materno-fetal da portadora de doença valvar reumática durante procedimento odontológico sob anestesia local / Maternal-fetal monitoring of patients with rheumatic heart disease during dental procedure under local anesthesia

Neves, Itamara Lucia Itagiba 15 February 2007 (has links)
Modificações na fisiologia do organismo da mulher ocorrem durante a gravidez em conseqüência às alterações hormonais, anatômicas e metabólicas. No sistema circulatório a modificação mais significativa é o aumento do débito cardíaco a partir do primeiro trimestre da gestação. Mulheres portadoras de cardiopatias podem apresentar graves complicações durante o período gestacional devido à inapropriada adaptação à sobrecarga hemodinâmica, mesmo em pacientes consideradas em capacidade funcional favorável, no início da gestação. A literatura carece de estudos dos efeitos dos anestésicos locais com ou sem vasoconstritor utilizados nos procedimentos odontológicos, sobre os parâmetros cardiovasculares de mulheres gestantes portadoras de valvopatias e seus conceptos. A escassez científica fez deste tema nosso objetivo de estudo: avaliar e analisar parâmetros da cardiotocografia, como freqüência cardíaca, motilidade fetal e contrações uterinas e de pressão arterial e eletrocardiográficos da gestante portadora de doença valvar reumática quando submetida à anestesia local com lidocaína, com e sem vasoconstritor, durante procedimento odontológico restaurador. Para tanto, a monitorização ambulatorial da pressão arterial (MAPA) e a eletrocardiografia ambulatorial (Holter) materna, ambas obtidas durante 24 horas e a cardiotografia (CTG) de 31 portadoras de cardiopatia reumática entre a 28ª e 37ª semana de gestação, nos períodos: (1) basal - 60 minutos antes do procedimento para MAPA e Holter e 20 minutos para CTG; (2) procedimento - 56+15,5minutos (média+desvio padrão); (3) pós-procedimento - 20 minutos; e (4) média das 24 horas para freqüência cardíaca e extra-sístoles e média da vigília e do sono para pressão arterial, permitiu a análise da variação desses parâmetros, utilizando-se lidocaína 2% sem vasoconstritor e lidocaína 2% com epinefrina 1:100.000, compondo-as em dois grupos. Demonstrou-se redução significativa nos valores de freqüência cardíaca materna durante o procedimento somente quando comparado aos demais períodos (p<0,001). Quando comparados os dois grupos, não houve diferença (p>0,05). Houve ocorrência de arritmia cardíaca em 9 (29,0%) pacientes, sendo 7 (41,8%) do grupo que recebeu anestesia com adrenalina. A pressão arterial materna não apresentou diferença quando comparamos os períodos ou os grupos (p>0,05). O mesmo ocorreu (p>0,05) nas análises comparativas dos parâmetros fetais obtidos por meio da CTG - número de contrações, nível e variabilidade da linha de base, número de acelerações da freqüência cardíaca fetal e padrão de reatividade fetal. Concluiu-se que o uso da lidocaína 2% associado à adrenalina mostrou-se seguro em procedimento odontológico durante a gestação de mulheres com cardiopatia valvar reumática. / During pregnancy, the organic systems of a woman are subjected to physiological modifications consequential to hormonal, anatomic and metabolical alterations. The most significant modification in the circulatory system is an increased cardiac output from the first three months of gestation. Women with heart disease may present with severe complications during the gestational period, because of inappropriate adaptation of her body to this hemodynamic overload, even those patients who are thought to have an appropriate functional capacity during early pregnancy. There are scant studies in the literature on the effects of local anesthetics, with and without vasoconstrictor, used in dental procedures on the cardiovascular variables of pregnant women with valvar disease, as well as on their concepti. Driven by this shortage, we decided to have this subject studied, by assessing and analyzing cardiotachographic parameters, such as heart rate, fetal motility and uterine contractions, in addition to blood pressure and electrocardiographic variables, in pregnant women with rheumatic valvar disease who undergo local anesthesia with lidocaine, with and without vasoconstrictor, during restorative dental procedure. For this, 31 rheumatic heart disease patients who were in their 28th to 37th week of gestation, had 24-hour ambulatory monitoring of their blood pressure (BP) and Holter electrocardiography (Holter-ECG), and cardiotocography (CTG), performed during: (1) baseline - 60 minutes before the procedure for BP and Holter- ECG monitoring, and 20 minutes before the procedure for CTG; (2) procedure - 56±15.5 minutes (mean±SD); (3) post-procedure - 20 minutes; and (4) mean 24-hour heart rate and extrasystoles measurement, and mean wake and sleeping periods BP monitoring. Variation of the above variables was analyzed in two groups, one with infusion of a 2% solution of lidocaine with vasoconstrictor, and the other with infusion of a 2% solution of lidocaine with epinephrine 1:100.000. The maternal heart rate values obtained during the procedure showed a significant reduction only in comparison with the other time periods (P<0.001). The comparison of the two groups did not reveal any significant difference (P>0.05). Cardiac arrhythmia was detected in 9 (29.0%) patients, 7 of them (41.8%) from the group who received anesthetics with epinephrine. Maternal blood pressure did not show any significant difference neither between time periods, nor between groups (P>0.05). The same occurred in the comparative analysis of the fetal parameters obtained during CTG -number of contractions, level and variability from baseline, number of fetal heart rate accelerations and fetal reactivity pattern. Our conclusion was that the use of 2% solution of lidocaine in association with epinephrine proved safe during dental procedure in pregnant women with rheumatic valvar cardiopathy.
322

Índice agroambiental para avaliar o uso de agrotóxicos (IAA) no Estado do Paraná / Agro-environmental index to evaluate the use of pesticides (IAA) in the State of Paraná

Casagrande, Alessandro 01 February 2018 (has links)
O Brasil está entre os três maiores consumidores de agrotóxicos no mundo. Atualmente, não há no país nenhum índice agroambiental de uso de agrotóxicos capaz de refletir os seus impactos nos sistemas naturais. Esta pesquisa teve como objetivo geral desenvolver uma metodologia para a criação de um índice destinado ao monitoramento do impacto do uso de agrotóxicos sobre o território paranaense. O estudo também considerou como objetivos específicos: i) propor o desenvolvimento do índice agroambiental para monitoramento do uso de agrotóxicos em bacias hidrográficas; ii) investigar a relação de indicadores que subsidiem o monitoramento de uso de agrotóxicos; iii) geoespacializar os dados na bacia em estudo por meio de mapas temáticos. A pesquisa propôs a criação de um índice baseado em três indicadores agroambientais: a) Indicador 1 - média da quantidade de quilos/litros de agrotóxicos por hectare por ano de área agricultável expresso no receituário agronômico dos produtos formulados receitados; b) Indicador 2 - potencial de periculosidade ambiental dos agrotóxicos e c) Indicador 3 - pluviosidade média anual de cada município para representar um maior ou menor grau de potencial de run-off. A pesquisa foi realizada em duas etapas: a etapa de cálculos e de produção cartográfica (mapas temáticos). Na etapa de cálculos, foi desenvolvida uma metodologia para tabular um grande conjunto de dados do Sistema de Monitoramento do Comércio e Uso de Agrotóxicos do Estado do Paraná - Siagro no intuito de subsidiar os indicadores. Na etapa cartográfica foram produzidos os mapas temáticos coropléticos no sentido de facilitar a visualização da informação geoespacializada. O estudo demonstrou ser possível utilizar o índice para elencar municípios prioritários para a gestão do risco agroambiental dentro de bacias hidrográficas, traduzindo uma grande quantidade de dados no recorte temporal estabelecido. Desta forma, possibilitou diminuir as aproximações na modelagem dos indicadores de uso de agrotóxicos utilizados atualmente no país. Concluiu-se que o índice pode ser utilizado para subsidiar a gestão do risco do uso de agrotóxicos não apenas para o uso em bacias hidrográficas, mas as outras áreas de estudo que tenham interesse nos impactos do uso de agrotóxicos. / Brazil is among the three largest consumers of pesticides in the world. There is currently no agri-environment index for pesticides use in the country capable of reflecting its impacts on natural systems.The general objective of this research was to develop a methodology for the monitoring impact of pesticides use in agriculture on the Paraná State environment. The study also considers the specific objectives: i) to propose the the agro-environmental index for monitoring the use of pesticides in river basins; ii) to investigate the list of indicators that subsidize the monitoring of the use of pesticides; iii) to geospatial data in the basin under study through thematic maps. The research proposed the creation of an index based on three agri- environmental indicators: a) indicator 1 - average amount of kilos/liters of pesticides per hectare of arable area expressed in the agronomic prescription of formulated products; b) indicator 2 - potential environmental hazard of pesticides and c) indicator 3 - annual average rainfall of each municipality to represent a greater or lesser degree of run-off potential. The research was carried out in two stages: the calculations part and cartographic production (thematic maps). In the calculation part, a methodology was developed to tabulate a large dataset derived from Monitoring System of the Trade and Use of Pesticides in the State of Paraná - Siagro, to subsidize the indicators. In the cartographic part, the thematic maps were produced to facilitate the visualization of geospatial information. The study demonstrated that it is possible to use the index to list priority municipalities for agro-environmental risk management within a river basin, translating a large amount of data into the established biennium. In this way, the main contribution of this work is the proposal of error reduction method in the modeling of pesticides indicators of use currently in the country. It was concluded that the index can be used to subsidize the risk management of the use of pesticides not only for use in river basins, but other areas of study that have concern about the impacts of the use of pesticides.
323

Proposta de protocolo de telemonitoramento sob demanda de sinais biomédicos usando internet das coisas, computação móvel e armazenamento em nuvem / Protocol proposal for on-demand remote monitoring of biomedical signals using internet of things, mobile computing and cloud storage

Machado, Francisco Muller 28 April 2016 (has links)
Este trabalho apresenta a proposta de um protocolo de comunicação de dados integrando tecnologias de internet das coisas, computação móvel e armazenamento em nuvem, aplicado ao telemonitoramento sob demanda de sinais fisiológicos. O objetivo do trabalho foi adquirir, transmitir, armazenar, receber e permitir a visualização sob demanda, mantendo a integridade da representação do sinal biomédico para a análise médica, sem alterar a mobilidade do paciente em monitoramento. O trabalho utiliza um canal de ECG, para adquirir o sinal de eletrocardiografia do paciente, que é conectado via Bluetooth com um dispositivo de computação móvel. O dispositivo de computação móvel, com acesso a internet sem fio, envia o sinal fisiológico através do protocolo proposto para uma base segura de armazenamento de informações em nuvem, podendo ser acessada sob demanda por um especialista para realizar a avaliação médica. O telemonitoramento sob demanda permite ao especialista: visualizar e analisar dados recentes, como se fosse um monitoramento remoto em tempo real do paciente; e visualizar e analisar dados anteriores que estão armazenados na nuvem, semelhante à análise de um exame realizado previamente. O protocolo proposto possui características de segurança da informação, mantendo a integridade da representação no tempo do sinal fisiológico, ainda que dados sejam corrompidos. O trabalho envolveu o uso de tecnologias recentes aplicadas às necessidades de registros de sinais fisiológicos. Estas tecnologias estão em evolução, os padrões não estão consolidados, ocorrendo alterações à medida que novas necessidades vão sendo apresentadas, assim como novas soluções venham a ser desenvolvidas. Como dispositivo de computação móvel foi utilizado neste trabalho um tablet, podendo ser utilizado um smartphone. O protocolo para este trabalho foi utilizado com o sinal de um canal de eletrocardiografia, podendo ser modificado para atender outras necessidades, incluindo outros sinais fisiológicos. Neste trabalho foi utilizado como sinal fisiológico o sinal de um simulador de ECG. / This work shows a proposal for a data communication protocol integrating internet of things technologies, mobile computing and cloud storage, applied to on-demand remote monitoring physiological signals. The aim of this work was to acquire, transmit, store, receive and allow the on-demand visualization, keeping the integrity of the biomedical signals representation for medical analysis, without changing the mobility of the patient being monitored. The work uses an ECG channel to acquire the patient’s electrocardiography signal, which is linked via Bluetooth to a mobile computing device. The mobile computing device, with wireless internet access, sends the physiological signal through the proposed protocol to a safe base of cloud information storage, which can be accessed on demand by a specialist to do the medical evaluation. On-demand remote monitoring allows the specialist to visualize and analyze recent data, as if it were real time remote monitoring of the patient, and visualize and analyze previous data that are stored in the cloud, similar to an analysis of a previously made exam. The proposed protocol has information security features, keeping the integrity of the time representation of the physiological signal, even if the data are corrupted. The work involved the use of new technologies applied to the necessity of physiological signals record. These technologies are evolving. The patterns are not consolidated, and changes are made as new necessities are presented and new solutions developed. For this work, it was used a tablet as a computing mobile device. However, a smartphone could also be used. The protocol was used with an electrocardiography channel signal, which can be modified to attend other necessities, including other physiological signals. As a physiological signal, for this work, it was used an ECG simulator signal.
324

Fluidoresponsividade em pacientes críticos sob ventilação mecânica: da pressão venosa central para ecocardiografia à beira leito / Fluoresponsiveness in critically ill patients under mechanical ventilation: from central venous pressure to bedside echocardiography

Livia Maria Ambrósio da Silva, Livia 21 July 2017 (has links)
Introdução: Prever a capacidade de resposta a fluidos continua sendo um desafio para os médicos que lidam com pacientes instáveis hemodinamicamente. A utilização de parâmetros estáticos, como pressão venosa central (PVC) tem sido usada por décadas, mas não é confiável, evidências robustas sugerem que seu uso deve ser abandonado. Ao longo dos últimos 15 anos, foram desenvolvidos vários testes dinâmicos, baseados no princípio de alteração da pré-carga cardíaca, usando as interações coração-pulmão, e, consequentemente do débito cardíaco. A elevação passiva das pernas (EPP), a infusão de pequenos volumes de fluidos, a variação da pressão de pulso (ΔPP), as variações nos diâmetros de grandes veias tem sido muito utilizados para avaliação de fluidoresponsividade (FR), neste contexto. Objetivo: Analisar e comparar medidas estáticas e dinâmicas antes, após EPP e após infusão de SF, verificando qual delas apresentam melhor FR. Métodos: Trinta e um pacientes instáveis hemodinamicamente e sob ventilação mecânica (VM) foram incluídos no estudo. Foram avaliados VTIFAO, VTIFMi, IDVCI, ΔPP, PVC, PAM antes de qualquer intervenção, após EPP e após infusão de 500ml SF. As variações dos parâmetros foram calculados para todos os pacientes. Resultados: Após EPP e infusão de SF o VTIFAO aumentou em 10% ou mais em 14 (45%) e 18 (58%) pacientes respectivamente, definidos como FR. A EPP previu a capacidade de resposta a fluidos com uma sensibilidade de 77,7%, especificidade de 100%, valor preditivo positivo de 100% e probabilidade de falso positivo de 0%. O parâmetro utilizado como padrão para FR foi o VTIFAO após SF. A PVC, o IDVCI, o ΔPP, PAM e avaliação médica não se mostraram capazes de avaliar adequadamente FR. Conclusão: Em pacientes instáveis hemodinamicamente e sob VM, a EPP foi capaz de avaliar FR com adequada sensibilidade e especificidade, podendo ser usada com segurança, antes da administração de fluidos. / Introduction: Predictig fluid responsiveness remains a constant challenge for physicians dealing with hemodynamically unstable patients. The use of static parameters, such as central venous pressure (CVP), although used for decades is not a trustworthy source, and the suggestion derived from more robust evidence suggests that the use of such should be abandoned. Over the last 15 years, various dynamic tests have been developed based on the principle of altering the cardiac preload, by using the heart-lung interactions and consequently cardiac output. Hence, Passive Leg Raising (PLR), the intake of small amounts of fluid, the variation of pulse pressure, variations in the diameter of large veins have all been widely used for evaluating fluid responsiveness (FR), within this context. Objective: The underlying objective behind this study was to test, if the non-invasive evaluation with transthoracic echocardiography, the Subaortic velocity time integral (VTI), the Distensibility Index of the Inferior Vena Cava (dIVC), the mitral velocity time integral (MTI), the (CVP) and the change in pulse pressure (ΔPP) after (PLR) and fluid infusion (500ml of saline solution) are able to predict the responsiveness of fluid therapy. Methods: Thirty one hemodynamically unstable patients, under mechanical ventilation (MV) were included in the study. Evaluations were made of VTI, MTI, DIVC), ΔPP and CVP before any intervention, after PLR and after infusion of 500ml saline solution. The variations of the parameters were calculated for all patients. Results: After PLR and infusion of saline solution, the VTI increased by 10% or more in 14 (45%) and 18 (58%) patients, respectively, defined as fluid responders. The PLR predicted a response capacity to fluids with a sensibility of 77,7%, specificity of 100%, a positive predictive value of 100% and a false positive probability of 0%. The CVP, dIVC, ΔPP, PAM and the medical evaluation were not capable of providing an adequate FR evaluation. Conclusion: In hemodynamically unstable patients under MV, PLR were capable of precisely predicting the capacity of FR. / Dissertação (Mestrado)
325

Desenvolvimento de métodos por cromatografia líquida acoplada à espectrometria de massas em tandem para análises de fármacos (LC-MS/MS no modo column switching com capilar monolítico de sílica híbrida), aminoácidos e neurotransmissores (HILIC-MS/MS) em amostras de plasma de pacientes esquizofrênicos. / Development of methods for liquid chromatography coupled to tandem mass spectrometry for drug analysis (LC-MS/MS in column switching mode with monolithic capillary hybrid silica), amino acids and neurotransmitters (HILIC-MS/MS) in plasma samples of schizophrenic patients.

Diego Soares Domingues 26 August 2015 (has links)
A esquizofrenia é um transtorno neuropsiquiátrico crônico que afeta aproximadamente 1% da população mundial. As teorias neurobiológicas descrevem que a esquizofrenia é essencialmente causada por alterações bioquímicas e estruturais do cérebro, devido às disfunções nos sistemas glutamatérgico, dopaminérgico e serotoninérgico. Desta forma, a determinação das concentrações de aminoácidos e neurotransmissores em amostras de plasma de pacientes esquizofrênicos pode auxiliar na avaliação da eficácia da terapia. Além dos antipsicóticos, medicação de primeira linha no tratamento inicial da esquizofrenia, a maioria dos pacientes também faz uso concomitante de outras classes de fármacos, tais como antidepressivos, anticonvulsivantes e ansiolíticos para minimizar os sintomas associados a esta doença. Nesta tese, um método empregando a precipitação de proteínas (PPT) e a cromatografia líquida por interação hidrofílica acoplada à espectrometria de massas em tandem (HILIC-MS/MS) foi adequadamente desenvolvido e validado para a determinação de aminoácidos (aspartato, serina, glicina, alanina, metionina, leucina, tirosina e triptofano) e neurotransmissores (glutamato e ácido -aminobutírico) em amostras de plasma de 35 pacientes esquizofrênicos em tratamento com clozapina (27 pacientes) e olanzapina (8 pacientes) para avaliar a eficácia do tratamento, tendo como controle 38 voluntários sadios. O método HILIC-MS/MS apresentou linearidade do LIQ (9,7 pmol mL-1 - 13,3 nmol mL-1) ao LSQ (19,4 nmol mL-1 - 800 nmol mL-1), tempo de análise de 3,0 min, exatidão com EPR de -18 a 19% e precisão com CV de 0,1 a 16% (LIQ). A análise de variância (ANOVA), seguida por teste post-hoc de Duncan, revelou que os níveis médios plasmáticos (nmol mL-1) de metionina (F2,70 = 3,14, p = 0,049) de pacientes esquizofrênicos em tratamento com olanzapina foram significativamente mais elevados, quando comparados aos valores obtidos com o grupo controle (voluntários saudáveis), já o nível de glutamato em pacientes esquizofrênicos em tratamento com clozapina apresentaram tendência a valores mais altos (F2.70 = 2,50, p = 0,090). Já os métodos, PPT/LC-MS/MS e LC-MS/MS no modo column switching utilizando uma coluna monolítica de sílica híbrida com grupos cianopropil na primeira dimensão, foram desenvolvidos e validados para a determinação dos antipsicóticos (olanzapina, quetiapina, clozapina, haloperidol e clorpromazina), antidepressivos (mirtazapina, paroxetina, citalopram, sertralina, imipramina, clomipramina e fluoxetina), anticonvulsivantes (carbamazepina e lamotrigina), e ansiolíticos (diazepam e clonazepam) em amostras de plasma de pacientes esquizofrênicos para fins de monitorização terapêutica. O método PPT/LC-MS/MS apresentou linearidade do LIQ (0,2 ng mL-1 - 5,0 ng mL-1) ao LSQ (40,5 ng mL-1 - 10,5 g mL-1), exatidão com EPR de -9,7 a 8,0%, e precisão com CV de 0,1 a 12%. Já o método LC-MS/MS no modo column switching apresentou linearidade do LIQ (63,0 pg mL-1 - 1250,0 pg mL-1) ao LSQ (40,5 ng mL-1 - 10,5 g mL-1), exatidão com EPR de -14 a 12% e precisão com CV de 0,6 a 6,5%. A pré-concentração seletiva dos fármacos na coluna monolítica com grupos cianopropil incorporados e a remoção dos componentes endógenos da amostra biológica, antes da separação cromatográfica, favoreceram a seletividade e detectabilidade do método LC-MS/MS no modo column switching. Este método quando comparado ao de referência PPT/LC-MS/MS, através da análise de 10 amostras de pacientes esquizofrênicos, não apresentou diferença significativa (teste t) entre as concentrações plasmáticas, podendo ser aplicado na monitorização terapêutica. Além deste fato, este método automatizado favoreceu a precisão, a exatidão e a freqüência analítica. / Schizophrenia is a chronic neuropsychiatric disorder that affects approximately 1% of the world population. According to neurobiological theories, schizophrenia stems from biochemical and structural alterations in the brain due to dysfunction in the glutamatergic, dopaminergic, and serotonergic systems. Determining the concentrations of amino acids and neurotransmitters in plasma samples from schizophrenic patients may assist evaluation of therapy effectiveness. In addition to antipsychotics (the first-line drug in the initial treatment of schizophrenia), most patients concomitantly use other classes of drugs such as antidepressants, anticonvulsants, and anxiolytics to minimize the symptoms associated with this disease. To evaluate treatment efficacy, in this thesis a method based on protein precipitation (PPT) and hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry (HILIC-MS/MS) has been properly developed and validated to determine amino acids (aspartate, serine, glycine, alanine, methionine, leucine, tyrosine, and tryptophan) and neurotransmitters (glutamate and -aminobutyric acid) in plasma samples obtained from 35 schizophrenia patients treated with clozapine (27 patients) or olanzapine (8 patients); 38 healthy volunteers served as controls. The HILIC-MS/MS method was linear for concentrations ranging from the LLOQ (9.7 pmol mL-1 - 13.3 nmol mL-1) to the ULOQ (19.4 nmol mL-1 - 800 nmol mL-1). The analysis time was 3.0 min. In the case of accuracy, RSE ranged from -18 to 19%. As for precision, CV lay between 0.1 and 16% (LLOQ). Analysis of variance (ANOVA) followed by post-hoc Duncan showed that the average methionine serum levels (nmol mL-1) (F2.70 = 3.14, p = 0.049) in schizophrenic patients treated with olanzapine were significantly higher as compared with the control group (healthy volunteers). The glutamate level in schizophrenic patients treated with clozapine tended to higher values (F2.70 = 2.50, p = 0.090). Concerning the analytical methods, PPT/LC-MS/MS and LC-MS/MS operating in the column-switching mode were developed and validated to determine antipsychotic (olanzapine, quetiapine, clozapine, haloperidol, and chlorpromazine), antidepressants (mirtazapine, paroxetine, citalopram, sertraline, imipramine, clomipramine, and fluoxetine), anticonvulsants (carbamazepine and lamotrigine), and anxiolytics (diazepam and clonazepam) in plasma samples taken from schizophrenic patients for therapeutic drug monitoring. A monolithic hybrid column containing silica with cyanopropyl groups in the first dimension was employed. The PPT/LC-MS/MS method was linear from the LLOQ (0.2 ng mL-1 - 5.0 ng mL-1) to the ULOQ (40.5 ng mL-1 - 10.5 g mL-1). In the case of accuracy, RSE ranged from -9.7 to 8.0%; as for precision, CV lay between 0.1 and 12%. LC-MS/MS in the column-switching mode was linear from the LLOQ (63.0 pg mL-1 - 1250.0 pg mL-1) to the ULOQ (40.5 ng mL-1 - 10.5 g mL-1). RSE ranged from -14 to 12%; CV lay between 0.6 and 6.5%. The drugs were selectively pre-concentrated in the monolithic column containing silica incorporated with cyanopropyl groups. For the LC-MS/MS method operating in the column-switching mode, the endogenous components of the biological sample of the LC-MS/MS method were removed before analysis. Analysis of 10 plasma samples obtained from schizophrenic patients did not reveal any significant differences (t test) between the LC-MS/MS method and the reference PPT/LC-MS/MS method. Therefore, LC-MS/MS can be applied in therapeutic monitoring, with the advantage that this method offers improved precision, accuracy, and analytical frequency.
326

Avaliação objetiva dos hábitos e barreiras da atividade física de portadores de doença pulmonar obstrutiva crônica / Objective assessment of barriers and habits of physical activity in patients with chronic obstructive pulmonary disease

Priscila Batista de Souza Amorim 10 July 2014 (has links)
INTRODUÇÃO: Pacientes com doença pulmonar obstrutiva crônica (DPOC) tem atividade física reduzida. Barreiras que limitam a atividade física e a medida objetiva da limitação ainda são pouco estudadas nesta população. Conhece-las permite um planejamento adequado para incremento da atividade de vida diária (AVD). OBJETIVO: Comparar a AVD de portadores de DPOC e controles com um sensor de movimento, identificar barreiras que impedem a AVD e correlaciona-los à gravidade da dispneia, ao teste de caminhada de 6 minutos (TC6) e um escore de limitação da AVD. MÉTODOS: O número de passos, a distância percorrida em quilômetros e o tempo de caminhada foram registrados por um acelerômetro de bolso e um pedômetro durante 7 dias consecutivos. Um questionário de barreiras percebidas e a escala AVD (LCADL) foram utilizados para qualificar fatores que impedem a AVD. A dispneia foi medida por duas escalas distintas e a capacidade física submáxima pelo TC6. RESULTADOS: Foram avaliados 40 sujeitos com DPOC e 40 controles saudáveis. Os pacientes com DPOC realizaram tempo menor de caminhada (68,5 ± 25,8 minutos/dia vs. 105,2 ± 49,4; p < 0,001), menor distância (3,9 ± 1,9 km/dia vs. 6,4 ± 3,2; p < 0,001) e menor número de passos/dia. A falta de estrutura, influência social e falta de vontade foram as principais barreiras referidas para realização de AVD. O TC6 correlacionou-se com os resultados do acelerômetro, mas o LCADL não. CONCLUSÃO: Portadores de DPOC são menos ativos quando comparados a adultos saudáveis. Sedentarismo e as barreiras para atividade física tem implicação imediata na prática clínica indicando medidas de intervenção precoce / INTRODUCTION: Patients with chronic obstructive pulmonary disease (COPD) have reduced physical activity. Barriers that limit physical activity and objective measures of limitation are poorly studied in this population. The knowledge of them allows a proper planning for increased physical activity. OBJECTIVES: To compare ADLs in COPD patients and controls using a motion sensor, identify perceived barriers that prevent AVD and correlate them to the severity of dyspnea, to the 6-minute walk test (6MWT) and a score of AVD limitation. METHODS: An pocket accelerometer and a pedometer recorded the number of steps, distance in Km and walking time for seven consecutive days. A survey of perceived barriers and the ADL scale (LCADL) were used to describe factors that prevent AVD. Dyspnea was measured by two different scales and submaximal exercise capacity by 6MWT. RESULTS: 40 subjects with COPD and 40 healthy controls were evaluated. Patients with COPD performed less time walking (68.5 ± 25.8 minutes / day vs. 105.2 ± 49.4; p < 0.001), shorter distance (3.9 ± 1.9 km / day vs. 6.4 ± 3.2; p < 0.001) and a smaller number of steps/day. The lack of infrastructure, social influences and unwillingness were the main barriers to performing ADLs. The 6MWT correlated with the results of the accelerometer, but not LCADL. CONCLUSION: Patients with COPD are less active compared to healthy adults. Sedentary and barriers to physical activity has immediate implications in clinical practice indicating early intervention measures
327

Monitorização materno-fetal da portadora de doença valvar reumática durante procedimento odontológico sob anestesia local / Maternal-fetal monitoring of patients with rheumatic heart disease during dental procedure under local anesthesia

Itamara Lucia Itagiba Neves 15 February 2007 (has links)
Modificações na fisiologia do organismo da mulher ocorrem durante a gravidez em conseqüência às alterações hormonais, anatômicas e metabólicas. No sistema circulatório a modificação mais significativa é o aumento do débito cardíaco a partir do primeiro trimestre da gestação. Mulheres portadoras de cardiopatias podem apresentar graves complicações durante o período gestacional devido à inapropriada adaptação à sobrecarga hemodinâmica, mesmo em pacientes consideradas em capacidade funcional favorável, no início da gestação. A literatura carece de estudos dos efeitos dos anestésicos locais com ou sem vasoconstritor utilizados nos procedimentos odontológicos, sobre os parâmetros cardiovasculares de mulheres gestantes portadoras de valvopatias e seus conceptos. A escassez científica fez deste tema nosso objetivo de estudo: avaliar e analisar parâmetros da cardiotocografia, como freqüência cardíaca, motilidade fetal e contrações uterinas e de pressão arterial e eletrocardiográficos da gestante portadora de doença valvar reumática quando submetida à anestesia local com lidocaína, com e sem vasoconstritor, durante procedimento odontológico restaurador. Para tanto, a monitorização ambulatorial da pressão arterial (MAPA) e a eletrocardiografia ambulatorial (Holter) materna, ambas obtidas durante 24 horas e a cardiotografia (CTG) de 31 portadoras de cardiopatia reumática entre a 28ª e 37ª semana de gestação, nos períodos: (1) basal - 60 minutos antes do procedimento para MAPA e Holter e 20 minutos para CTG; (2) procedimento - 56+15,5minutos (média+desvio padrão); (3) pós-procedimento - 20 minutos; e (4) média das 24 horas para freqüência cardíaca e extra-sístoles e média da vigília e do sono para pressão arterial, permitiu a análise da variação desses parâmetros, utilizando-se lidocaína 2% sem vasoconstritor e lidocaína 2% com epinefrina 1:100.000, compondo-as em dois grupos. Demonstrou-se redução significativa nos valores de freqüência cardíaca materna durante o procedimento somente quando comparado aos demais períodos (p<0,001). Quando comparados os dois grupos, não houve diferença (p>0,05). Houve ocorrência de arritmia cardíaca em 9 (29,0%) pacientes, sendo 7 (41,8%) do grupo que recebeu anestesia com adrenalina. A pressão arterial materna não apresentou diferença quando comparamos os períodos ou os grupos (p>0,05). O mesmo ocorreu (p>0,05) nas análises comparativas dos parâmetros fetais obtidos por meio da CTG - número de contrações, nível e variabilidade da linha de base, número de acelerações da freqüência cardíaca fetal e padrão de reatividade fetal. Concluiu-se que o uso da lidocaína 2% associado à adrenalina mostrou-se seguro em procedimento odontológico durante a gestação de mulheres com cardiopatia valvar reumática. / During pregnancy, the organic systems of a woman are subjected to physiological modifications consequential to hormonal, anatomic and metabolical alterations. The most significant modification in the circulatory system is an increased cardiac output from the first three months of gestation. Women with heart disease may present with severe complications during the gestational period, because of inappropriate adaptation of her body to this hemodynamic overload, even those patients who are thought to have an appropriate functional capacity during early pregnancy. There are scant studies in the literature on the effects of local anesthetics, with and without vasoconstrictor, used in dental procedures on the cardiovascular variables of pregnant women with valvar disease, as well as on their concepti. Driven by this shortage, we decided to have this subject studied, by assessing and analyzing cardiotachographic parameters, such as heart rate, fetal motility and uterine contractions, in addition to blood pressure and electrocardiographic variables, in pregnant women with rheumatic valvar disease who undergo local anesthesia with lidocaine, with and without vasoconstrictor, during restorative dental procedure. For this, 31 rheumatic heart disease patients who were in their 28th to 37th week of gestation, had 24-hour ambulatory monitoring of their blood pressure (BP) and Holter electrocardiography (Holter-ECG), and cardiotocography (CTG), performed during: (1) baseline - 60 minutes before the procedure for BP and Holter- ECG monitoring, and 20 minutes before the procedure for CTG; (2) procedure - 56±15.5 minutes (mean±SD); (3) post-procedure - 20 minutes; and (4) mean 24-hour heart rate and extrasystoles measurement, and mean wake and sleeping periods BP monitoring. Variation of the above variables was analyzed in two groups, one with infusion of a 2% solution of lidocaine with vasoconstrictor, and the other with infusion of a 2% solution of lidocaine with epinephrine 1:100.000. The maternal heart rate values obtained during the procedure showed a significant reduction only in comparison with the other time periods (P<0.001). The comparison of the two groups did not reveal any significant difference (P>0.05). Cardiac arrhythmia was detected in 9 (29.0%) patients, 7 of them (41.8%) from the group who received anesthetics with epinephrine. Maternal blood pressure did not show any significant difference neither between time periods, nor between groups (P>0.05). The same occurred in the comparative analysis of the fetal parameters obtained during CTG -number of contractions, level and variability from baseline, number of fetal heart rate accelerations and fetal reactivity pattern. Our conclusion was that the use of 2% solution of lidocaine in association with epinephrine proved safe during dental procedure in pregnant women with rheumatic valvar cardiopathy.

Page generated in 0.0906 seconds