• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 333
  • 136
  • 65
  • 33
  • 25
  • 22
  • 20
  • 19
  • 12
  • 7
  • 6
  • 4
  • 3
  • 3
  • 3
  • Tagged with
  • 801
  • 146
  • 129
  • 116
  • 115
  • 107
  • 94
  • 90
  • 80
  • 71
  • 63
  • 59
  • 56
  • 53
  • 53
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
691

Desenvolvimento de um modelo experimental de crioablação vertebral em suínos guiada por tomografia computadorizada de feixe cônico / Development of an experimental model of cone beam computed tomography guided vertebral cryoablation in swine

Ricardo Miguel Costa de Freitas 29 October 2015 (has links)
INTRODUÇÃO: A criocirurgia (crioablação) percutânea em tecidos ósseos próximos da medula espinhal e sistema nervoso periférico tem sido feita na prática clínica, porém sem estudos experimentais que provem sua segurança e eficácia. O objetivo deste trabalho foi desenvolver um modelo experimental suíno in vivo de crioablação vertebral guiada por tomografia computadorizada de feixe cônico (TCFC). Um estudo preliminar de morfometria da coluna vertebral suína por imagens de TCFC foi realizado. Um protocolo específico de crioablação foi criado para adaptar a bola de gelo às dimensões da vértebra suína e testado em modelos in vitro, ex vivo e in vivo. MÉTODOS: O comitê institucional de cuidados com os animais aprovou este estudo. Dezesseis parâmetros anatômicos foram medidos em 36 vértebras lombares suínas e comparados às medidas aferidas nas imagens de TCFC e TC multidetectores (TCMD). Três simuladores in vitro / ex vivo foram desenvolvidos para o posicionamento de sensores de temperatura (termopares) em volta de uma sonda de congelamento. As isotermas foram obtidas durante um protocolo duplo de congelamento-descongelamento de 2-8 minutos. Vinte e duas crioablações vertebrais guiadas por TCFC foram realizadas em oito suínos, mediante termometria e dissecção por dióxido de carbono (CO2) no espaço epidural a fim de proteger os nervos. O seguimento clínico foi realizado até seis dias antes da eutanásia. Os dados clínicos e radiológicos foram correlacionados com o estudo histopatológico à microscopia de luz (n=20) ou eletrônica de transmissão (n=2). RESULTADOS: Na avaliação anatômica da coluna lombar suína a TCFC se mostrou um método de imagem comparável à TCMD e ao estudo anatômico, com correlação significativa (p < 0,05) em todas as variáveis, exceto aquelas que incluiu o tecido cartilaginoso dos planaltos vertebrais. As isotermas registradas foram mais frias no modelo ex vivo imerso em gel (-34 °C e -2 °C; -30 °C e 3 °C; -10 °C e 13 °C, respectivamente), do que nos modelos in vitro (-23 °C e 3 °C; -7 °C e 10 °C; 1 °C e 16 °C) ou ex vivo sem gel (-30 °C e 28 °C). No estudo in vivo, a demonstração das sondas de congelamento no corpo vertebral e do CO2 epidural pelas imagens de TCFC foi bem sucedida em todos os procedimentos. A taxa de complicação maior foi de 4,5%. A distância entre a sonda de congelamento e o canal vertebral (Cp-Sc) foi o parâmetro mais eficiente para categorizar as temperaturas do canal vertebral inferiores a 19 °C à análise do modelo de regressão logística (p < 0,004). Nenhum infiltrado inflamatório perineural foi identificado à microscopia de luz. O suíno cujas vertebras foram submetidas a análise ultraestrutural não apresentou déficit neurológico, embora tenha sido evidenciada a ruptura da bainha de mielina em algumas fibras neurais maiores. CONCLUSÕES: A TCFC foi validada como método de imagens para a análise de vértebras suínas. O modelo ex vivo em gel caracterizou melhor a preservação do frio no tecido ósseo. A combinação de um protocolo específico de congelamento associado a medidas de proteção epidural tornou viável e exequível a crioablação vertebral suína guiada por TCFC. A análise ultraestrutural mostrou modificações precoces das fibras nervosas, sem correlação clínica / INTRODUCTION: Percutaneous spine cryosurgery (cryoablation) close to nerves and spinal cord has been performed in the clinical practice, however without experimental studies proving its safety and efficacy. The aim of this work was to develop an experimental swine model of in vivo cone beam computed tomography (CBCT) guided vertebral cryoablation. A preliminary morphometric study of the porcine spine by CBCT imaging was carried out. A specific cryoablation protocol was proposed to adapt the \"ice ball\" to the swine vertebrae dimensions. Subsequently, the protocol was tested in in vitro, ex vivo and in vivo models. METHODS: The institutional animal care committee approved this study. Sixteen anatomical parameters were measured in 36 lumbar swine vertebrae and compared to the same measurements of the CBCT and multidetector CT (MDCT). Three models of in vitro / ex vivo studies were developed for the positioning of thermocouples around the cryoprobe. Isotherms were obtained from measured temperatures for each minute during a 2-8 minutes double freezing-thawing protocol. Twenty -two CBCT-guided vertebral cryoablations were performed in eight pigs. Epidural thermocouples registered the temperatures while carbon dioxide (CO2) was injected in the epidural space to protect nerves. The clinical follow-up was carried out until six days before euthanasia. Clinical and radiologic data were correlated to the histopathology study with light microscopy (n=20) or electron transmission microscopy (n=2). RESULTS: CBCT was proven to be a comparable imaging method to MDCT with significant correlation (p < 0.05) in all variables, except in those including the cartilaginous tissue of the vertebral plateau. The registered isotherms were colder in the ex vivo model embedded in gel (-34 °C and -2 °C; -30 °C and 3 °C; -10 °C and 13 °C, respectively) than in the in vitro model (-23 °C and 3 °C; -7 °C and 10 °C; 1 °C and 16 °C) or the ex vivo model without gel (-30 °C and 28 °C). In the in vivo study the CBCT imaging was well succeeded to demonstrate the cryoprobes inserted in the vertebral body and the epidural CO2 in all procedures. The major complication rate was 4.5%. The distance between the cryoprobe and the spinal canal (Cp-Sc) was the most efficient parameter to categorize the vertebral canal temperatures below 19 °C in the logistic regression model analysis (p < 0.004). Perineural inflammatory infiltrate was not identified in the light microscopy analysis. One swine did not present neurological deficits, although the ultra-structural analysis has evidenced myelin sheath disruption in some large neural fibers. CONCLUSIONS: The CBCT imaging was validated as an imaging method for the swine vertebrae analysis. The ex vivo model embedded in gel featured better the cold preservation in the bone tissue. The combination of a specific freezing protocol associated with epidural protective measures allowed the feasibility of the CBCT-guided vertebral cryoablation in the swine model. The ultra-structural analysis showed early modifications of the nerve fibers
692

Avaliação da força dos músculos do tronco em idosas : reprodutibilidade, associação com o desempenho funcional e efeitos dos treinamentos funcional e tradicional

Mesquita, Marceli Matos Andrade 09 April 2018 (has links)
The maintenance of the trunk muscles strength presents great importance in the elderly’s health, since it is related to a better performance during the daily activities. However, scientific literature limitations are found when analyzing the tests to measure the strength of these muscles and, in addition, the importance of these muscles in functional performance in the elderly people is not clear. Therefore, the objective of this dissertation was: I) to evaluate the reproducibility of the maximal isometric trunk strength test in the elderly women; II) to verify the association between strength and endurance in the trunk muscles on measures of functional performance in elderly women; and III) to analyze the effects of functional and traditional training on maximal isometric strength and endurance in elderly women. Study I verified the reproducibility of the maximal strength test of the trunk muscles in the elderly, in two days of evaluations, through Interclass Correlation Coefficient, Coefficient of Variation, Minimum Detectable Change, Standard Error of Measure, as well as graphical analysis of Bland-Altman. The study results showed high to very high interclass correlation (extensors = 0.93, flexors = 0.86, respectively); low variation (9% for both muscle groups); and minimal detectable change acceptable (extensors = 51.1 N, flexors = 48.9 N). Furthermore, the Bland-Altman analysis reveals low bias and values within the limits of agreement. In study II, a multiple linear regression was performed with the purpose of explaining to what magnitude the strength and endurance of the trunk muscles contribute to functional performance in elderly women. Thus, there was a participation of the trunk extensor muscles endurance that ranged from 17.9% to 24.4% in functional performance in the elderly. In study III, a randomized and controlled clinical trial was conducted with three groups: functional training, traditional training and control group. The intervention groups performed a training with functional and progressive characteristics, so that the traditional training group performed the exercises in analytical machines and the functional training group, exercises with characteristics of movement patterns in a multiplanar and coordinated manner, incorporating multiple joints. The groups were evaluated before and after 12 training weeks through trunk muscles maximal strength test. After 12 training weeks, it was verified that the functional training group obtained a statistically significant improvement for all variables analyzed: maximum strength test, trunk extensor and flexor muscles strength and endurance ratio. The traditional training group was superior only in the variable of trunk extensor muscles strength development rate. Accordingly, it is concluded that the trunk muscles maximal strength test in elderly women presents high reproducibility; there is a great association between the trunk muscles endurance in the functional performance and the functional training seems more effective than the traditional training in relation to the increase of the trunk muscles maximal strength and endurance, in addition to the rate of trunk flexor muscles strength development. / A manutenção da força dos músculos do tronco apresenta grande importância na saúde em idosos, uma vez que está relacionada com um melhor desempenho durante as atividades de vida diária. Entretanto, limitações são encontradas na literatura científica ao analisar os testes para mensurar a força desses músculos e, além disso, não está clara a importância desses músculos no desempenho funcional em idosos. Diante disso, o objetivo desta dissertação foi: I) avaliar a reprodutibilidade do teste de força isométrica máxima do tronco em idosas; II) verificar a associação entre a força e a endurance do tronco sobre as medidas de desempenho funcional em idosas; e III) analisar os efeitos dos treinamentos funcional e tradicional sobre a força isométrica máxima e a endurance do tronco em idosas. O estudo I verificou a reprodutibilidade do teste de força máxima dos músculos do tronco em idosas em dois dias de avaliações, através do Coeficiente de Correlação Interclasse, do Coeficiente de Variação, da Mínima Mudança Detectável, do Erro Padrão de Medida e também da análise gráfica de Bland-Altman. Os achados desse estudo revelaram correlação interclasse alta a muita alta (extensores=0,93; flexores=0,86, respectivamente); baixa variação (9% para os dois grupos musculares); e mínima mudança detectável aceitável (extensores=51,1 N; flexores=48,9 N). Além disso, a análise de Bland-Altman revela baixo viés e valores dentro dos limites de concordância. No estudo II, foi realizada uma regressão linear múltipla com o intuito de explicar em que magnitude a força e a endurance dos músculos do tronco contribuem no desempenho funcional em idosas. Dessa forma, houve uma participação da endurance dos músculos extensores do tronco, que variou entre 17,9% a 24,4% no desempenho funcional em idosas. Já no estudo III, foi realizado um ensaio clínico randomizado e controlado com três grupos: treinamento funcional, treinamento tradicional e grupo controle. Os grupos de intervenção realizaram um treinamento com características funcional e progressiva, de forma que o grupo treinamento tradicional realizou os exercícios em máquinas analíticas e o grupo treinamento funcional, exercícios com características de padrões de movimentos de maneira multiplanar e coordenada, incorporando múltiplas articulações. Aplicadas 12 semanas de treinamento, foi constatado que o grupo treinamento funcional obteve melhora significativa para todas as variáveis analisadas: teste de força máxima, taxa de desenvolvimento de força e endurance dos músculos extensores e flexores do tronco. O grupo treinamento tradicional foi superior apenas na variável de taxa de desenvolvimento de força dos músculos extensores do tronco. Assim, conclui-se que o teste de força máxima para os músculos do tronco em idosas apresenta alta reprodutibilidade; há associações entre a endurance dos músculos do tronco e desempenho funcional, e o treinamento funcional parece mais eficaz que o treinamento tradicional em relação ao aumento de força máxima e endurance dos músculos do tronco, além da taxa de desenvolvimento de força dos músculos flexores do tronco. / São Cristóvão, SE
693

Tamanduá-bandeira (Myrmecophaga tridactyla): Anatomia aplicada a radiografia e tomografia do aparato hióide e coluna vertebral / Giant anteater (Myrmecophaga tridactyla Linnaeus, 1758): Anatomy applied to radriography and tomography of hyoid apparatus and vertebral column

BOGOEVICH, Andria de Melo 20 September 2011 (has links)
Made available in DSpace on 2014-07-29T15:07:36Z (GMT). No. of bitstreams: 1 Dissertacao Andria Bogoevich.pdf: 1442294 bytes, checksum: ab1d215a31c38e78aab1e4a97a85e070 (MD5) Previous issue date: 2011-09-20 / The giant anteater is a peculiar mammal which during its evolutionary process, has undergone several body changes due to their insect-base diet. Although it is distributed throughout the country, it is a species typical of the Cerrado, which is threatened with extinction. In the last decade there has been an improvement in access to methods of imaging diagnostic in veterinary medicine, the availability of modern and faster techniques. These techniques have revolutionized the ability to explore non-invasive body parts. For a better interpretation of these techniques, knowledge of regional anatomy is required. However, data on radiographic anatomy of giant anteaters have not been reported. The aim of this study is to characterize and describe the outline contour of the spine bone and the hyoid bone of the giant anteater using radiographic and computed tomography images. Seven giant anteaters at various ages, from IBAMA, were used for radiographic examination and two adults for CT. The spine along its entire length and the hyoid elements were evaluated in all animals using both imaging techniques. Radiography provided satisfactory images of the bony contours and location of these structures, although the CT was more efficient to provide images with less overlap between them, allowing details identification such as the Xenarthrous process in the lumbar vertebrae, characteristic of the species, and the visualization of the V-bone in the hyoid apparatus. / O tamanduá-bandeira é um mamífero peculiar que durante o processo evolutivo sofreu diversas adaptações em seu organismo devido a sua dieta composta de insetos. Embora distribuída por todo o território nacional, é uma espécie típica do cerrado que se encontra ameaçada de extinção. Na última década houve uma melhora no acesso aos métodos de diagnóstico por imagem na medicina veterinária, com a disponibilidade de técnicas mais modernas e velozes. Essas técnicas revolucionaram a habilidade de explorar de forma não-invasiva as partes do corpo. Para uma boa interpretação dessas técnicas é necessário o conhecimento anatômico regional. Apesar de sua ampla distribuição e de sua importância, dados sobre anatomia radiográfica do tamanduá-bandeira ainda não foram relatados na literatura. O objetivo desse trabalho é caracterizar e descrever o contorno ósseo da coluna vertebral e do osso hióide do tamanduá-bandeira utilizando para isso imagens radiográficas e tomográficas. Foram utilizados sete tamanduás-bandeiras de variadas idades, provenientes do IBAMA para os exames radiográficos e dois adultos para os tomográficos. A coluna vertebral em toda sua extensão e os elementos hióideos foram avaliados em todos os animais através de ambos as técnicas de imagem. A radiografia forneceu imagens satisfatórias sobre os contornos ósseos e a localização dessas estruturas, entretanto a tomografia se mostrou mais eficiente ao fornecer imagens com menor sobreposição entre as mesmas, possibilitando a identificação de detalhes ósseos como o processo xenarthro nas vértebras lombares, característico da espécie, e no aparato hióide a visualização do formato em V do basitireóide.
694

Filme à base de quitosana comparado à gordura autógena na prevenção de aderências pós-laminectomia dorsal em coelhos / Film based on chitosan compared to autologous fat in the prevention of postoperative adhesions dorsal laminectomy in rabbits

GOMES, Filipe Augusto Sales 30 January 2009 (has links)
Made available in DSpace on 2014-07-29T15:07:54Z (GMT). No. of bitstreams: 1 dissertacao Filipe ciencia Animal - Clinica e Cirurgia Animal.pdf: 1546193 bytes, checksum: 01b61544014ff3cebd3f43ddb04b8408 (MD5) Previous issue date: 2009-01-30 / The adhesions formation after surgical procedures in the spine is a subject well studied in neurosurgery, according to the discomfort and postoperative pain suffered by patients. Several studies have been performed using anti-inflammatories, autologous grafts, xenografts and xenologer biomaterials and even in film form and gel with the aim of reducing or preventing adhesion formation. The aim of this study was to compare the film based on chitosan with autogenous fat in preventing dural adhesions in rabbits. This technique was compared to the technique used routinely by neurosurgeons who, in most cases, using autogenous fat. We used 24 adult male rabbits of New Zealand, and 15 and 30 days postoperatively (PO) the spinal cords of animals underwent myelography and histological evaluation. The animals were randomly divided equally into two groups (group G and Q), and further subdivided into four subgroups: G15, Q15, G30 and Q30 according to time points and the material used. In the group Q, a laminectomy performed between L1-L2 was occluded with the film based on chitosan and in the Group G the defect was repaired with autogenous free fat graft. In assessing myelography, there was a moderate compression of the column spinal cord both in group G as in group Q. In two rabbits of group Q the compression was attributed to severe disruption of the stabilization made with surgical steel wire. There was no significant difference (p &#8804; 0.05) between groups and subgroups. After the pre-established postoperatively, fibrous adhesion from mild to intense between the dura and the implant was noted in animals from both groups, with fibrosis and collagen fibers interspread with the tissue and implant withought, no statistically significant difference (p &#8804; 0.05) between groups and subgroups. There were cell infiltrates and giant cells that were more intense in the group Q. At 15 and 30 days postoperatively, the films based on chitosan were coated by inflammatory cells with areas of central necrosis. At 30 days postoperatively, the material had a fibrous capsule surrounding the inflammatory focus and the implant was noticed statistically significant (p &#8804; 0.05) of 5% when comparing the groups and subgroups. Based on the results we can conclude that the film based on chitosan, as well as a free autogenous fat reduces the extent of dural adhesions in rabbits, however, the film based on chitosan as well as any foreign body, induces crhonic and intenses inflammatory responses in the rabbit / A formação de aderências após procedimentos cirúrgicos na coluna vertebral é um tema bastante estudado na neurocirurgia, em função do desconforto e dores pós-operatórias sofridas pelos pacientes operados. Diversos estudos já foram realizados utilizando antiinflamatórios, enxertos autólogos, heterólogos e xenólogos e ainda biomateriais na forma de filme e gel com a finalidade de reduzir ou prevenir a formação de aderências. O objetivo deste estudo foi comparar o filme à base de quitosana com a gordura autógena na prevenção de aderências durais em coelhos. Tal técnica foi comparada à técnica realizada rotineiramente pelos neurocirurgiões que, na maioria dos casos, utilizam a gordura autógena. Foram utilizados 24 coelhos da raça Nova Zelândia, machos, adultos, e após 15 e 30 dias de pós-operatório (PO) as medulas espinhais dos animais foram submetidas à avaliação mielográfica e histológica. Os animais foram distribuídos aleatoriamente em dois grupos (grupo G e grupo Q) de igual número, sendo posteriormente subdivididos nos subgrupos G15,Q15, G30 e Q30 de acordo com os momentos de avaliação e o material utilizado. Nos animais do grupo Q, a laminectomia realizada entre L1-L2 foi ocluida com o filme à base de quitosana e no grupo G o defeito foi reparado com enxerto de gordura autógena livre. Na avaliação mielográfica, foi observada compressão moderada na coluna dorsal da medula espinhal tanto nos animais do grupo G quanto nos animais do grupo Q. Em dois coelhos do grupo Q ocorreu compressão grave atribuída à ruptura da estabilização feita com fio de aço cirúrgico. Não foi observada diferença significativa (p&#8804;0,05) entre os grupos e subgrupos. Decorridos os períodos pré-estabelecidos de PO, foi notado nos animais de ambos os grupos, aderência fibrosa de leve a intensa entre a dura-máter e o implante, com fibrose e fibras colágenas entremeadas ao tecido conjuntivo e implante, sem diferença estatística significativa (p&#8804;0,05) entre os grupos e subgrupos. Verificou-se infiltrados celulares e células gigantes, sendo este achado mais intenso nos animais do grupo Q. Aos 15 e 30 dias de PO, os filmes à base de quitosana encontravam-se revestidos por células inflamatórias com áreas de necrose central. Aos 30 dias de PO, o material apresentava cápsula fibrosa circundando o foco inflamatório e o implante, tendo sido notada diferença estatística significância (p&#8804;0,05) de 5%, quando comparados os grupos e os subgrupos entre si. Com base nos resultados pode-se concluir que o filme à base de quitosana, assim como a gordura autógena livre reduz a extensão das aderências durais em coelhos, porém, o filme à base de quitosana assim como todo corpo estranho, induz respostas inflamatórias tissulares crônicas e intensas no coelho
695

Incidência e fatores de risco para fratura vertebral por osteoporose em idosos brasileiros da comunidade: um estudo prospectivo de base populacional. São Paulo Ageing e Health (SPAH) Study / Vertebral fractures, Incidence and risk factors for osteoporotic vertebral fracture in low-income community-dwelling elderly: a population-based prospective cohort study in Brazil

Diogo Souza Domiciano 05 February 2015 (has links)
As fraturas vertebrais por osteoporose conferem risco aumentado de novas fraturas por fragilidade e maior mortalidade. Não há dados consistentes acerca da incidência de fratura vertebral osteoporótica em países de baixa/média renda, que têm experimentado aumento da expectativa de vida e envelhecimento populacional acelerado nas últimas décadas. Os objetivos deste estudo foram determinar a incidência de fratura vertebral osteoporótica, diagnosticada por radiografia, bem como identificar os principais fatores de risco para fratura em idosos brasileiros da comunidade, em um estudo coorte prospectivo de base populacional. Setecentos e sete indivíduos da comunidade, com 65 anos ou mais, foram avaliados através de radiografias da coluna vertebral obtidas no início do estudo e após um tempo médio de seguimento de 4,3 ± 0,8 anos. Nova fratura vertebral foi definida como uma alteração na morfologia vertebral resultando em maior grau de deformidade na segunda radiografia (graus 1-3), quando comparado com o exame inicial. Questionário (dados clínicos), medida da densidade mineral óssea (DMO) e exames laboratoriais foram realizados na avaliação inicial. Modelos de regressão multivariada de Poisson foram construídos para identificar os preditores independentes de fratura vertebral. Quatrocentos e quarenta e nove mulheres (72,9±4,8 anos) e 258 homens (72,3±4,7 anos) foram incluídos no estudo. A incidência de fratura vertebral ajustada para a idade foi 40,3/1000 pessoas-ano em mulheres e 30,6/1000 pessoas-ano em homens. Na análise multivariada três modelos possíveis de fatores de risco para fratura foram determinados em mulheres: 1. idade (RR 2,46, IC 95% 1,66-3,65, para cada aumento em 10 anos), fratura osteoporótica prévia (RR 1,65, IC 95% 1,00-2,71) e DMO da coluna lombar (RR 1,21, IC 95% 1,03-1,41, para cada redução de 1 DP na DMO); 2. idade (RR 2,25, IC 95% 1,52-3,34, para cada aumento em 10 anos) e DMO do colo do fêmur (RR 1,42, IC 95% 1,11-1,81, para cada redução de 1 DP na DMO); 3. Idade (RR 2,11, IC 95% 1,41-3,15, para cada aumento em 10 anos) e DMO do quadril total (RR 1,56, IC 95% 1,21-2,0, para cada redução de 1 DP na DMO). Em homens, o maior quartil de distribuição do telopeptídeo C-terminal (CTX) sérico (RR 1,96, IC 95% 0,98-3,91) e fratura prévia (RR 2,10, 95% CI 1,00-4,39) foram preditores de nova fratura vertebral, após ajustes para idade, peso e atividade física. Este é o primeiro estudo longitudinal que determinou a incidência de fratura vertebral em uma amostra de base populacional de idosos na América Latina. A frequência de fratura vertebral foi elevada nessa população. Idade, fratura prévia, DMO e marcadores bioquímicos da remodelação óssea foram preditores de nova fratura vertebral / Vertebral fractures are associated with increased future fracture risk and mortality. No data on incidence of osteoporotic vertebral fracture have been reported in low-income countries where the population\'s aging has been faster. Thus, we sought to describe the incidence and risk factors for radiographic vertebral fracture in a longitudinal prospective Brazilian population-based elderly cohort. 707 older adults (449 women and 258 men) were evaluated with spinal radiographs obtained at baseline and after a mean follow-up of 4.3 ± 0.8 years. New vertebral fracture was defined as distinct alteration in the morphology of vertebrae resulting in higher grade of deformity on the second radiograph when compared to the baseline radiograph. Clinical questionnaire, bone mineral density (BMD), and laboratory tests were performed at baseline. Multivariate Poisson regression models were used to identify independent predictors of fracture. The age-standardized incidence of vertebral fracture was 40.3/1,000 person-years in women and 30.6/1,000 in men. In women, three models of risk factors for fracture were fitted: (1) age (relative risks (RR) 2.46, 95 % confidence interval (CI) 1.66-3.65), previous osteoporotic fracture (RR 1.65, 95 % CI 1.00-2.71), and lumbar spine BMD (RR 1.21, 95 % CI 1.03-1.41); (2) age (RR 2.25, 95 % CI 1.52-3.34) and femoral neck BMD (RR 1.42, 95 % CI 1.11-1.81); (3) age (RR 2.11, 95 % CI 1.41-3.15) and total hip BMD (RR 1.56, 95 % CI 1.21-2.0). In men, the highest quartile of cross-linked C-telopeptide (CTx) (RR 1.96, 95 % CI 0.98-3.91) and prior fracture (RR 2.10, 95 % CI 1.00-4.39) were predictors of new vertebral fracture. This is the first population-based study to ascertain the incidence of vertebral fracture in elderly Latin Americans, confirming the high frequency of the disorder. Age, prior fracture, BMD, and bone turnover were predictors of the short-term incidence of vertebral fracture
696

Resultados da vertebroplastia percutânea na doença vertebral cervical / Results of percutaneous vertebroplasty in the cervical spine

Francisco José Arruda Mont'Alverne 17 November 2008 (has links)
A vertebroplastia percutânea (VP) consiste na injeção de polimetilmetacrilato (PMMA) no corpo vertebral para alívio da dor e estabilização vertebral, porém seu uso na região cervical é restrito. No intuito de avaliar a efetividade e a segurança da VP na região cervical (VPC), foram avaliados 75 pacientes que se submeteram à VPC (n=101) por doença maligna (n=69) ou hemangioma vertebral (n=6) no período de janeiro de 1994 a outubro de 2007. A VPC foi realizada por uma abordagem ântero-lateral guiada por fluoroscopia. A dor foi graduada por uma escala variando de 0 a 10. O seguimento clinico (período médio de 8,8 meses) foi obtido em 57 (76%) pacientes: 48 tiveram a VPC indicada para controle da dor e nove para estabilização vertebral. Os dados foram analisados de forma univariada e multivariada. A efetividade analgésica foi obtida em 37 (77,1%) dos 48 pacientes seguidos, tendo sido associada ao volume de cimento injetado (P=0,011) e ao preenchimento vertebral (P=0,007) na análise multivariada. A estabilidade vertebral foi observada em 55 (96,5%) dos 57 pacientes, não se correlacionando com as variáveis estudadas. A curva de ROC identificou o preenchimento vertebral como preditor da efetividade analgésica (P=0,008), sendo 50% o melhor ponto de corte para discriminar a maior probabilidade de efetividade analgésica (sensibilidade de 78,0% e especificidade de 62,5%). O extravasamento de cimento foi identificado em 83 (82,2%) das 101 vértebras tratadas não se correlacionando com as variáveis estudadas. As complicações clínicas foram detectadas em 13 (17,3 %) pacientes: complicações locais em 10 (13,3%) e sistêmicas em três (4%) pacientes. As complicações clínicas foram estatisticamente relacionadas à ruptura do muro posterior (P=0,026) e ao extravasamento de PMMA no plexo venoso transverso (P=0,023). A taxa de mortalidade e morbidade a longo termo foi de 1,3% (um paciente) e 1,3% (um paciente). Pode se inferir que a VPC é um procedimento efetivo e seguro, sem se negligenciar os riscos potenciais de complicações. O preenchimento vertebral e o volume de cimento foram associados à efetividade analgésica, mas não à estabilidade vertebral. O preenchimento vertebral teve o maior poder discriminatório da efetividade analgésica, tendo sido obtido com o ponto de corte de 50 % o melhor equilíbrio entre sensibilidade e especificidade para se determinar a efetividade analgésica / Percutaneous vertebroplasty (PV) consists of an injection of polymethylmethacrylate (PMMA) into the vertebral body for pain relief and spinal stabilization, however reports of PV in the cervical spine (CPV) are scarce in the literature. To evaluate the effectiveness and security of CPV, we evaluated 75 patients (mean age, 51.3 years) who underwent CPV (n=101) for malignancies (n=69) and vertebral hemangiomas (n=6) between January 1994 and October 2007. CPV was performed via an antero-lateral approach, using fluoroscopic guidance. Pain intensity was scored with a scale ranging from 0 to 10. Follow-up (mean time of 8.8 months) was avaible in 57 (76 %) patients: 48 of them had CPV indicated for pain control and nine for spinal stabilization. Data were analysed by means of univariate and multivariate analysis. Pain improvement was observed in 37 (77.1%) out of 48 followed patients and was correlated in multivariate analysis with cement volume (P=0.011) and with vertebral filling (P=0.007). Spinal stabilization was observed in 55 (96.5%) of 57 followed patients and was related with none of the evaluated variables. The ROC curve identified the vertebral filling as a good predictor of pain improvement (P=0.008). The best cut-off point to discriminate pain improvement was 50% of vertebral filling (78.0% sensitivity and 62.5% specificity). In 83 (82.2%) of the 101 treated vertebral levels, at least one type of PMMA leakage was found. None of the evaluated factors were related significantly to PMMA leakage. Clinical complications were detected in 13 (17.3%) patients: local complications in 10 (13.3%) patients and systemic clinical complications in three (4.0%) patients. Posterior wall disruption (P=0.026) and transverse venous PMMA leakage (P=0.023) were significantly associated with clinical complications. Long-term morbidity and mortality rate was 1.3% (one patient) and 1.3% (one patient). CPV is a safe and efficacious procedure, but the potential for local and systemic complications must be considered. Cement volume and vertebral filling were associated with pain improvement but not with spinal stability. Vertebral filling has a good performance to predict pain improvement and a cut-off of 50% of vertebral filing obtained the best compromise between sensitivity and specificity to discriminate pain improvement
697

Desenvolvimento de um sistema para avaliação dos desvios da coluna vertebral em três dimensões- Spine3D / Development of a new three-dimensional system for evaluating spine deformities - Spine3D

Thomaz Nogueira Burke 21 May 2013 (has links)
Introdução: Escoliose é definida como um complexo desalinhamento tridimensional da coluna vertebral na qual há o aparecimento de uma curvatura lateral no plano coronal, normalmente associada com o aplanamento das curvaturas no plano sagital e rotação vertebral em seu eixo longitudinal. O padrão ouro para seu diagnóstico e monitoramento é a medida radiográfica pelo ângulo de Cobb, que possui como principais desvantagens o fato de não avaliar as curvas em três dimensões e expor os pacientes, principalmente os que estão em fase de crescimento, a consideráveis doses de radiação. Objetivo: Esta pesquisa teve como objetivo principal o desenvolvimento de um sistema de avaliação e representação da coluna vertebral em três dimensões, capaz de possibilitar ao usuário a análise quantitativa dos desvios da coluna vertebral nos planos coronal, sagital e transverso. São objetivos secundários estimar a precisão e a exatidão do sistema proposto, e avaliar a sua aplicabilidade a partir de um estudo de caso. Métodos: O Sistema desenvolvido, denominado de Spine 3D, é baseado no uso do controle de videogame Wiimote para rastrear LEDs infravermelhos que compõe um marcador multiplanar em uma cena, e tem como objetivo reconstruir em um ambiente 3D a pose das vértebras torácicas e lombares e, com isto, obter as variáveis angulares e de translação que descrevem seu alinhamento nos planos coronal, sagital e transverso. O experimento para a avaliação da exatidão e precisão consistiu em posicionar o marcador a 50 centímetros de distância do Wiimote, ambos alinhados em um mesmo plano. O marcador foi transladado em intervalos de 10 mm e rotacionado em 5°, 10°, 20° e 30° nos eixos X, Y e Z, com auxílio de um inclinômetro e um paquímetro digital. Os dados foram coletados a 100 Hz. A exatidão foi calculada comparando os resultados encontrados pelo sistema com os valores obtidos pelo inclinômetro e paquímetro digital. A precisão foi calculada a partir do desvio-padrão dos pontos coletados. Resultados: A exatidão média do sistema foi de 0,90° e 0,78mm. A precisão média do sistema foi de 0,62° e 0,42mm. Para o ângulo de Cobb na escoliose, a exatidão e precisão foram de 1,46° e 1,72°, e para a cifose torácica e lordose lombar, a exatidão e precisão foram de 2,82° e 1,60°, respectivamente. Durante o estudo de caso, a diferença entre o Spine3D e a radiografia, para o ângulo de Cobb foi de 1,3° para escoliose curva torácica e 2,24° para escoliose curva lombar. Conclusão: O sistema mostrou ter boa exatidão e precisão após os testes de validação interna. O estudo de caso sugere que a técnica possui potencial para aplicação clínica na avaliação dos desvios da coluna vertebral em três dimensões. / Introduction: Scoliosis is a complex three-dimensional malalignment of the vertebral column in which there is lateral curvature of the spine in the coronal plane, usually associated with flattening of the contour in the sagittal plane and rotation of the vertebrae around their longitudinal axes. Routine clinical analysis of the scoliotic spine is currently based on the radiographic measurement of Cobb angle. Although considered as the golden standard, it has the disadvantage of look over only the two-dimensional aspects of the curve and, over a period of years, the patient will be exposed to a large dose of radiation, especially in early onset curves. There is evidence that this may increase the risk of developing several types of cancer. Objective: This paper describes a new low-cost and radiation-free system to evaluate the three-dimensional aspects of scoliosis, and its concurrent validation in terms of accuracy and precision. Its applicability was tested in a case study. Methods: The system, named Spine3D, has the ability to track an infrared beacon equipped with LEDs (IRLED) to reconstruct the pose of each lumbar and thoracic vertebra in 3D space. The system also calculates the spine alignment to the coronal, sagittal and transverse planes. For accuracy and precision evaluation of the system, the beacon was positioned 50 cm away from the IR camera (Wiimote), aligned with in the same plane. The beacon was increasingly translated at 10 mm intervals and rotated at 5°, 10°, 20° and 30° on all three axes. The capture achieved rate was of 100 Hz roughly and accuracy was calculated comparing the results of Spine3D, digital paquimeter and digital inclinometer. Precision was considered as the standard deviation of the collected data. Results: The average accuracy obtained for the system is 0.90° and 0.78 mm, with precision of 0.62° and 0.42 mm. For Cobb angle calculations in coronal plane, accuracy and precision were of 1.46° and 1.72°, and for thoracic kyphosis and lumbar lordosis, the values were 2.82° and 1.60°. During the case study, the difference between the Cobb angle measured by Spine3D and radiography was 1.3° for thoracic scoliosis curve and 2.24° for lumbar scoliosis curve. Conclusion: The Spine3D system offers a non-invasive and radiation-free alternative for three-dimensional spine assessment and representation. Future studies should indicate if the measures taken by the Spine3D system have correlation with the Cobb angle measured by other methods.
698

Ocorrência de traumatismo raquidiano em doentes em coma decorrente de traumatismo cranioencefálico / Spine injuries in patents presenting coma due to head injury

Jefferson Rosi Junior 05 April 2012 (has links)
Foi realizado estudo prospectivo com o objetivo de se determinar a ocorrência de traumatismo raquidiano (TR) em 355 doentes em coma decorrente de traumatismo cranioencefálico (TCE) resultante de acidente de tráfego atendidos no Pronto Socorro de Neurocirurgia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (PSNCHCFMUSP) de 1° de setembro de 2003 a 31 de dezembro de 2009. Todos os doentes foram submetidos ao exame físico e neurológico e à tomografia computadorizada (TC) do corpo inteiro para diagnosticar-se e avaliar-se a gravidade das lesões traumáticas encefálicas, vertebrais ou de outras regiões no momento da admissão ao PSNCHCFMUSP. Em 69 (19,4%) doentes, foi(ram) diagnosticada(s) lesão(ões) na coluna vertebral com o exame de TC da coluna vertebral. As idades dos doentes variaram de 12 a 55 anos (média de 29,0 anos). Eram do sexo masculino 57 (82,6%) doentes. As causas do(s) traumatismo(s) foi(ram) acidente(s) envolvendo motocicleta em 28 (40,6%) casos, atropelamento em 21 (30,5%), colisão de automóvel, caminhão ou caminhonete, em 18 (26,1%) ou acidente com bicicleta em dois (2,9%). Hemorragia subaracnóidea traumática foi a anormalidade intracraniana traumática mais evidenciada no exame de TC do crânio; ocorreu em 57 (82,6%). O(s) processo(s) transverso(s) foi(ram) o(s) segmento(s) vertebral(is) mais acometido(s) pela(s) fratura(s). A sétima vértebra cervical foi a mais lesada; nela identificaram-se fraturas em 24 (34,8%) doentes. Evidenciou-se que a distribuição das fraturas foi similar ao longo das demais vértebras da coluna cervical, quatro primeiras vértebras torácicas e vértebras lombares. Em oito (11,6%) doentes a(s) lesão(ões) neurológica(s) foi(ram) classificada(s) como Frankel A, e nos demais 61(88,4%), como Frankel não-A. Houve necessidade de cirurgia espinal em 24 (34,8%) doentes e de neurocirurgia craniana em 18 (26,0%) doentes. A Escala de Recuperação de Glasgow foi aplicada para avaliar-se as condições neurológicas do doente no momento da alta hospitalar e revelou ocorrência de óbito em dois (2,9%) doentes. Concluiuse que é recomendada a avaliação clínica e também com métodos de imagem da coluna vertebral nos doentes em coma decorrente de TCE / The author presents a prospective study aiming the evaluation of coexistence of spinal injury (SI) in 355 patients presenting coma due to craniocerebral trauma assisted at the Emergency Room of the Hospital das Clínicas of the University of São Paulo Medical School, from September, 1st, 2003 to december, 31th,2009. All patients underwent physical and neurological examination and had computed tomography (CT) scanning of the entire body to diagnose and evaluate the severity of brain and spinal injury at the time of admission. Traumatic lesions of the spine were diagnosed in 69 (19.4%) patients. The ages of patients ranged from 12 to 55 years (mean = 29,0 years).The SI predominated in males, corresponding to 57 (82.6%) patients. The causes of the trauma were motorcycle accident in 28 (40.6%) cases, running over in 21(30.5%), car collision 18 (26.1%) cases and bicycle accident in two (2.9%). Traumatic subarachnoid hemorrhage was the most common traumatic intracranial abnormality in the CT images; it was identified in 57 (82.6%) patients. The transverse process was the most common vertebral part presenting fracture(s). The 7th cervical vertebra was individually the most commonly affected; traumatic lesion of this vertebra presented in 24 (34.8%) patients. The diagnosis of fracture(s) was similar in the other cervical vertebrae and occurred also in the first four thoracic and in the lumbar vertebrae. Severe neurological deficit secondary to spine fracture was diagnosed in eight (11.6%) patients, classified as Frankel A. The others 61(88.4%) patients did not present complete spinal cord or spinal roots neurological deficits were classified as Frankel non A. The Recovery Scale of Glasgow was used to evaluate the neurological status at discharge from hospital. Two (2.9%) patients died. Spinal surgery was necessary in 24 (34.8%) patients and cranial surgery in 18 (26.0%). It was concluded that in addition to clinical evaluation, the CT imaging of the spine is recommended in patients in coma due to mechanical traumatic head injury
699

Avaliação da utilização de um programa computadorizado para aplicação da escala de Basso, Beattie e Bresnahan (BBB) em ratos Wistar / Evaluation of the use of a computer software for the application of the Basso, Beattie e Bresnahan (BBB) scale in Wistar rats

Alessandra Eira Iague Sleiman Molina 31 October 2012 (has links)
A escala de Basso, Beattie e Brenahan (BBB) serve para avaliação da recuperação locomotora em ratos com lesão medular nos níveis torácicos. É baseada em critérios observacionais da movimentação do animal durante a marcha e atribui uma pontuação de 0 a 21 segundo a gravidade da lesão neurológica. Menor pontuação, maior gravidade. Tal escala pode ser aplicada de modo livre, em que o pesquisador observa o rato e emite uma nota; pode ser aplicada de modo dirigido, em que o pesquisador segue uma sequência de perguntas pré-estabelecidas e atribui uma nota; ou de modo automatizado, em que as respostas à mesma sequência de perguntas são fornecidas a um programa de computador, que emitirá uma nota com o grau de lesão. Trabalhos já publicados mostram que existe variação interobservadores na aplicação desta escala. O objetivo do trabalho foi avaliar a utilização de um programa de computador para auxiliar os pesquisadores na atribuição de notas na aplicação da escala BBB e comparar as notas obtidas por esses pesquisadores quando o fazem de modo livre, dirigido e utilizando um programa automatizado. Para testar o programa, foi realizada lesão medular padronizada em 12 ratos Wistar utilizando-se metodologia da New York University - Impactor System. Na sequência, filmou-se a movimentação dos ratos para aplicação da escala BBB no 28o dia. Foram convocados oito pesquisadores do laboratório de estudos de trauma raquimedular da Universidade de São Paulo. As avaliações de dois chefes do laboratório, com 15 anos de experiência na aplicação da escala, foram consideradas o padrão ouro na avaliação. Seis pesquisadores receberam as filmagens dos ratos com o objetivo de aplicar a escala BBB nas três metologias: livre, dirigida e automatizada, com 15 dias de intervalo entre as avaliações. A ordem da aplicação da escala foi randomizada entre os pesquisadores e a ordem dos ratos, nas análises das filmagens, também foi variada para evitar a memorização por parte dos pesquisadores. Os resultados interavaliadores e entre os métodos mostraram-se similares. A comparação dos resultados entre os seis pesquisadores e os dois considerados padrão ouro mostrou diferença para dois pesquisadores nos métodos livre e dirigido. Concluiu-se que a aplicação da escala BBB pelo modo automatizado não apresentou diferença em relação ao padrão ouro para todos os avaliadores, e que, quando feita pelo modo livre, dirigido e automatizado, não apresentou diferença em relação ao padrão ouro, considerando a média dos avaliadores em cada método / The BBB is an evaluation scale in the locomotor recovery in rats presenting thoracic medullar injury. It is based on observation criteria of animal movement while walking, and a provides a score ranging from 0 to 21 according to the severity of the neurological injury. The lower the score, the higher the severity. Such scale can be applied by using a free system of analysis, that is, when the researcher observes the rat and gives a score. The evaluation can also be made in an assisted way, where the researcher follows a series of pre-established questions and then gives a score,or in an automated manner, where the answers to the same sequence of questions are provided to a computer program, which provides a score with the degree of injury. Published research shows that there is a interobserver variation in the scale application The objective of the present study was to evaluate the use of a computer program for helping researchers in the scoring by the BBB scale, and comparing these grades obtained when they are making a free evaluation, in an assisted evaluation and while using a computer program. In order to test the program, a standardized spinal cord injury was performed in 12 Wistar rats in accordance with the methodology proposed by the New York University - Impactor System. Then, the rat movements were filmed on the 28th day, so that the Basso, Bettie and Bresnahan scale could be applied. Eight researchers working in the spinal cord injury laboratory in the University of São Paulo were invited for the study. Two heads of the laboratory, with a fifteen year-experience in the usage and application of the scale, were considered to be gold standard in the evaluation. Six researchers were shown the films and asked to apply the BBB scale by the three methodologies: free, assisted and computerized, with a fifteen-day interval between evaluations. The scale application order was randomized among the researchers as well as the order of the rats in the film analysis so as to avoid memorization on the part of the researchers. Results proved to be similar between researchers and methods. The comparison of results among the six researchers and the gold standard ones showed discrepancies in two of the researchers in the free and assisted methods of analysis. It was concluded that the BBB scale evaluated through the computer method was no different than the gold standard for all the researchers. When the analysis was performed using the free, assisted and computer-assisted methods, no difference was observed in relation to the gold standard considering the mean values in each method
700

Uso do método de elementos finitos na análise biomecânica de parafusos do sistema de fixação vertebral / Use of finite element analysis in the biomechanical analysis of screws used for spine fixation system.

Ana Paula Macedo 09 November 2009 (has links)
O parafuso como elemento de ancoragem de sistemas de fixação vertebral já é há muito utilizado. Porém a forma de distribuição da tensão gerada por ele na região de ancoragem não está ainda bem clara. O método de elementos finitos (MEF) é um método matemático desenvolvido no século passado e permite, quando em um estudo estático, avaliar reações internas de estruturas ao se aplicar uma força. Este estudo teve por objetivo analisar as tensões e deformações internas geradas por parafusos do sistema de fixação vertebral por meio do MEF. Os Parafusos USS1 de 5, 6 e 7 mm de diâmetro e 45 mm de comprimento (Grupo 1 G1, Grupo 2 G2 e Grupo 3 - G3) e os parafusos USS2 anterior, USS2 posterior de 6,2mm de diâmetro e USS1 de 6 mm de diâmetro e 30 mm de comprimento (Grupo 4 G4, Grupo 5 G5 e Grupo 6 - G6) foram utilizados neste estudo. Para validação dos modelos foram utilizados: ensaio mecânico de arrancamento do parafuso em corpos de prova de poliuretana com densidade de 0,16 g/cm3 e resultados de ensaios de arrancamento encontrados na literatura. Foi confeccionado um modelo tridimensional para cada conjunto parafuso e poliuretana estudado no programa SolidWorks®2006. Foram confeccionados 30 corpos de prova em poliuretana para validação de G1, G2 e G3, sendo 10 corpos de prova para cada grupo. O orifício piloto foi realizado por broca de 3,8 mm para G1 e 4,8 mm para G2 e G3. Os modelos dos grupos G4, G5 e G6 foram validados por resultados encontrados na literatura de ensaios em poliuretana de mesma densidade e orifício piloto realizados por sonda de 3,8 mm para G4 e G5 e 4,8mm para G6. A análise pelo método de elementos finitos, foi realizada no programa ANSYS®Workbench 10.0. A validação foi obtida pela comparação da rigidez relativa obtida no ensaio mecânico e o resultado da simulação pelo MEF. Foram encontradas divergências de 8,3% para G1, 3,1% para G2, 0,5% para G3, 14,4% para G4, 9,5% para G5 e 10,3% para G6, sendo todas consideradas aceitáveis. Validados os modelos, os grupos G4 e G6, utilizados na fixação anterior, foram submetidos à força de compressão, tração e dobramento lateral. Os grupos G5 e G6, empregados na fixação posterior, foram submetidos à força de compressão, tração, flexão e extensão. Na fixação anterior as menores tensões foram encontradas para G4 e as maiores para G6 para todas as forças aplicadas. Na fixação posterior as menores tensões foram encontradas para G5 e as maiores para G6 para todas as forças aplicadas. As maiores tensões foram geradas ao se realizar o dobramento lateral na fixação anterior e a extensão na fixação posterior. / Screws have been used to stabilize spine fixation systems. However, stress distribution around them is not clear yet. The finite element method (FEM) is a mathematic model developed in the last century and allows evaluating internal reactions of the structure submitted to a load in a static analysis. The present study aimed to evaluate stress and internal deformation caused by screws of the spine fixation system using FEM. USS1 screws measuring 5, 6 and 7 mm in diameter and 45 mm in length (Group 1 G1, Group 2 G2 and Group 3 G3) and the screws USS2 anterior, USS2 posterior measuring 6.2 mm in diameter and USS1 measuring 6 mm in diameter and 30 mm in length (Group 4 G4, Group 5 G5 and Group 6 G6) were used in the present study. For validation models, mechanical tests evaluating pull-out strength in polyurethane samples presenting density of 0.16 g/cm3, and results of pull-out tests related in the literature were used. Threedimensional (3D) models were built for each screw-polyurethane sample set using SolidWorks® 2006 software. Thirty polyurethane samples were made for G1, G2 and G3 validation, 10 for each group. The pilot hole was made using a 3.8 mm drew for G1, and 4.8 mm for G2 and G3. The G4, G5 and G6 models were validated based on literature results that used polyurethane of same density and pilot hole made using 3.8 mm probe for G4 and G5, and 4.8 mm for G6. The FEM analysis was performed using ANSYS®Workbench 10.0 software. Validation was reached by comparing relative stiffness obtained in mechanical tests and results of FEM simulation. Differences of 8.3% for G1, 3.1% for G2, 0.5% for G3, 14.4% for G4, 9.5% for G5, and 10.3% for G6 were found, but all values were considered acceptable. Validated the models, G4 and G6 groups, used for anterior fixation, were submitted to compression, traction and lateral bending load. The G5 and G6 groups, used for posterior fixation, were submitted to compression, traction, flexion and extension force. In the anterior fixation, lower stress were found for G4, and greater for G6 at all applied forces. In the posterior fixation, lower stress were found for G5 and greater for G6 at all applied forces. Greater stress were caused simulating lateral bending in the anterior fixation, and extension in the posterior fixation.

Page generated in 0.0533 seconds