• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 6
  • Tagged with
  • 20
  • 11
  • 10
  • 8
  • 8
  • 8
  • 8
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Termisk energilagring i borrhål : En studie av borrhålets temperaturinverkan på värmepumpens värmefaktor / Borehole thermal energy storage : A study of the boreholes temperature impact on the heat pump's coefficient of performance

Raschke, Marcus, Peterson, Victor January 2014 (has links)
Sverige har en hög andel installerade bergvärmepumpar, som är en typ av vätska-vatten värmepump. Ett problem som finns för befintliga bergvärmesystem är att berget med tiden kyls ned då returslangen till borrhålet konstant levererar kyla till berget. Till följd av detta mister systemet en betydande del av sin verkningsgrad samtidigt som det i extrema fall kan leda till permanent isbildning i borrhålet. Ett sätt att motverka detta problem är att tillämpa termisk energilagring i bergvärmesystemets borrhål. Den internationella benämningen för denna teknik är ”Borehole Thermal Energy Storage, BTES”. Rapporten har behandlat en friliggande enplansvilla med ett befintligt bergvärmesystem som tillämpar termisk energilagring i bergvärmesystemets borrhål med solvärme. Två beräkningsfall har gjorts och resultatet från simuleringarna i en upprättad beräkningsmodell visar att en temperaturhöjning i borrhålet inte alltid innebär en årlig energibesparing. Vid varje grads temperaturhöjning sker en ökning av värmepumpens COP med ca 1,85 % enligt ett linjärt samband för höga temperaturdifferenser över värmepumpen. Detta motsvarar en kostnadsbesparing på 1,02 %/°C. Detta gäller för normala förhållanden med en framledningstemperatur för tappvarmvatten och rumsvärmare på 55 ⁰C. Med en högre energiförbrukning finns alltså större besparingar att göra. Vid mycket låga temperaturdifferenser mellan förångare och kondensor sker dock större procentuella förändringar, vilket medför att lågtemperatursystem kan bidra till en större energibesparing. I normalfallet är dessa system svåra att räkna hem för småhus. För en god lönsamhet krävs en optimerad systemlösning och effektiv styrning av cirkulationspumpar och andra samspelande komponenter med en PLC. I framtiden kommer dock sannolikt värmepumparnas mekaniska verkningsgrad att öka med bättre teknik och även energipriset som följd av politiska beslut, tillgång etc. Detta innebär att varje besparad kilowattimme kommer att bli mer värd. / Sweden has a high proportion of installed geothermal heat pumps, which are a type of liquid -water heat pump. One problem that exists for existing geothermal heating systems is that the rock in time cool down when the return hose to the borehole constantly supply cooling to the rock. As a result of this the system loses a significant portion of their efficiency while in extreme cases has led to the permanent ice in the borehole. One way to counter this problem is to apply thermal energy storage in the geothermal heating systems borehole. The international term for this technique is "Borehole Thermal Energy Storage, BTES". This report has analyzed a detached single storey house with an existing geothermal heating system utilizing thermal energy storage in the geothermal heating systems borehole with solar heating. Two calculation cases has been made and the results of the simulations in an established computational model shows that an increase in temperature in the borehole does not always result in an annual energy savings. Each degree of increased temperature is an increase in the heat pumps COP of 1.85 %, according to a linear relationship for high temperature differences across the heat pump. This results in a cost saving of 1.02 %/°C. This applies to normal conditions with a radiator temperature at 55 ⁰ C. With higher energy consumption can greater savings be made. At very low temperature differences between the evaporator and condenser is however larger percentage changes made, which means that low temperature systems can lead to greater energy savings. Typically, these systems are difficult to recoup for small detached houses. For a good profitability requires an optimized system solution and efficient control of circulation pumps and other interacting components with a PLC. In the future the heat pump mechanical efficiency will probably increase with better technology and even energy prices as a result of political decisions, access, etc. This means that each spared kilowatt hour will be worth more.
12

Val av värmesystem vid nybyggnation av ett flerbostadshus i mellersta Sverige : En simuleringsstudie

Olmats, Oscar January 2023 (has links)
The choice of heating system in new residential buildings has a significant effect onthe total life cycle-cost. Rising energy prices and tougher energy demands for newbuildings creates incentive for energy- and cost-efficient solutions. The purpose ofthis project is therefore to investigate how the choice and sizing of a heating systemin a building can be performed with focus on cost-efficiency. The project is conducted as a case study on a residential building during the buildingphase on behalf of INTEC Dalarna AB, a technical engineering company. The project aim is to answer the following questions: – What heating system of district heating, ground source heat pumps or air towater heat pumps is the most cost-effective for a new residential building inthe middle of Sweden? – Is there a specific combination of a heat pump of arbitrary size and peak heating system that is particularly advantageous for the building? – Is IDA ICE suitable for simulation of energy use in buildings with heatpumps? – Does high energy-efficiency also mean high cost-efficiency for the building? The questions will be answered with building simulation software IDA Indoor Climate and Energy along with capital budgeting. The capital budgeting will be performed with net present value and payoff period for the heat pumps over choosingdistrict heating. The results of the project show that a system with ground source heat pumps with acapacity of 50 percent of the annual peak heat demand and electricity for peak loadsis the most cost-efficient option for the building. However, the most energy efficient option is a ground source heat pump with a capacity of 50 percent of the annual peak heat demand with district heating for peak loads. The project also shows that IDA ICE is suitable for simulating the performance of heat pumps in buildings.The conclusion is that a smaller system of ground source is more cost-efficient forthe building, and that the most energy efficient option is not always equal to themost cost-efficient over time.
13

Free cooling and PVT integration in a ground-source heat pump (GSHP) system

Pourier, Christopher January 2023 (has links)
The performance of ground-source heat pump (GSHP) systems can be negatively affected over time by soil temperature degradation of boreholes (BH) in heating dominated climates. Land area is scarce in the dense urban environments typical of multi-family houses (MFH) and can lead to accelerated degradation- in tight BH fields. Heat extracted from photovoltaic thermal collectors (PVT) can help with BH regeneration; thus, limiting degradation. Additionally, free cooling (FC) is proposed in this study to tackle the anticipated cooling demandi ncrease in Sweden, while resolving the listed challenges of GSHP systems. A novel multi-source (MS) system integrating FC, PVT and GSHP together shall be investigated in this study. Firstly, implementing FC in a GSHP system for the scenario considered only provided marginal regeneration of the BH in the longterm. Both the SPF4+ and total life cycle cost (TLCC) of an FC+GSHP and GSHPsystem remained virtually constant. Furthermore, operation interference of FC and PVT in the MS system can be mitigated by considering their relative location in the system. In this study, cooling is the priority, thus placing the FC system after the BH field but before the PVT system in the brine loop is recommended. In that case, only 0.56% of the annual cooling is not delivered due to FC operation interference and the PVT thermal yield is decreased on average by 3.52%. By decreasing the BH spacing from 15 to 5 m, a slight SPF4+ increase to 3.22 is possible in a system with FC and 48 PVT collectors. With a sensitivity analysis it was shown that if a 15% decrease is achieved in electricity prices then the TLCC of this system can be lower than the TLCC of 2.13 MSEK for a GSHP system. / Prestandan hos ytjordvärmepump (GSHP) kan påverkas negativt över tid av försämrad marktemperatur i borrhål (BH) i klimat som domineras av uppvärmning. I täta stadsmiljöer med flerfamiljshus (MFH) är markytan knapp, vilket kan leda till accelererad nedbrytning i trånga BH-fält. Värme som utvinns från solfångare (PVT) kan bidra till regenerering av BH, vilket begränsar nedbrytningen. Dessutom föreslås frikyla (FC) i denna studie för att hantera den förväntade ökningen av kylbehovet i Sverige, samtidigt som man löser de listade utmaningarna med GSHP-system. Ett nytt multikällsystem (MS) som integrerar FC, PVT och GSHP tillsammans ska undersökas i denna studie. För det första gav implementeringen av FC i ett GSHP-system för det aktuella scenariot endast marginell regenerering av BH på lång sikt. Både SPF4+ och den totala livscykelkostnaden (TLCC) för ett FC+GSHP och GSHP-system förblev praktiskt taget konstant. Dessutom kan driftstörningar från FC och PVT i MS-systemet minskas genom att ta hänsyn till deras relativa placering i systemet. I denna studie prioriteras kylning, och därför rekommenderas att FC-systemet placeras efter BH-fältet men före PVT-systemet i brineslingan. Endast 0.56% av den årliga kylningen levereras inte på grund av störningar i FC-driften och PVT:s värmeutbyte minskar i genomsnitt med 3.52%. Genom att minska BH-avståndet från 15 till 5 m är en liten ökning av SPF4+ till 3.22 möjlig i ett system med FC och 48 PVT-kollektorer. En känslighetsanalys visade att om elpriserna minskar med 15% kan TLCC för detta system bli lägre än TLCC på 2.13 MSEK för ett GSHP-system.
14

Multi-Data Approach for Subsurface Imaging: Combining Borehole and GPR- Data for Improved Analysis

Yngvesson, Pontus January 2023 (has links)
The investigation to understand the subsurface and its features has long been asubject of interest for various fields, including fields such as archaeology and infras-tructure projects. However, traditional excavation methods are often costly and time-consuming. In their place, alternative techniques such as borehole drilling, which isitself expensive, and ground-penetrating radar (GPR), which produces a good butdistorted image, have gained popularity. Nonetheless, the limitations of each methodimpede them from meeting the requirements of subsurface exploration. This Mas-ter’s thesis introduces an approach combining these two methods to overcome theirlimitations and enhance their accuracy to understand the subsurface.This thesis aims to demonstrate the feasibility and effectiveness of integratingborehole drilling and GPR for subsurface exploration. Specifically, the integrationof borehole with GPR-profiles will be examined to enhance their practicality andaccuracy, meaning that this thesis will investigate the utilization of borehole datato update and adjust GPR-profiles, thereby providing more precise and informativedata for further analysis.The findings of this work indicate that combining borehole drilling and GPR-profiling to improve and update the accuracy of the GPR-profiles is entirely feasibleand results in a substantially improved subsurface exploration capability. Further,the outcomes of this thesis suggest that the integrated approach can generate amore precise representation of the underground structure. Ultimately, the proposedintegration of borehole drilling and GPR-profiling presents a promising approach toenhance the accuracy and efficiency of subsurface exploration and has the potentialto be valuable in a wide range of fields.i
15

Ekonomisk driftoptimering av det termiska energisystemet på Karlstad centralsjukhus : Framtida driftrekommendationer baserat på linjärprogrammering / Economic operational optimization of the thermal energy system at Karlstad central hospital : Future operation recommendations based on linear programming

Mellander, Petter January 2022 (has links)
Studien använder linjärprogrammering för att optimera driften av det termiska energisystemet på Karlstad centralsjukhus ur ett ekonomiskt perspektiv. Bakgrunden till studien är de höga elpriser som rådde under slutet av 2021 samt att det i dagsläget finns kunskapsluckor angående hur systemet bör köras optimalt. Studien baseras på driftdata från 2021. Energisystemet som optimeras är uppbyggt av kylvärmepumpar, bergvärmepumpar, kylmaskiner, frikyla, fjärrvärme och marklager. Ett förhållande för hur många kWh termisk energi som produceras per tillförd kWh el tas fram för samtliga komponenter, vilket sedan används för att modellera energisystemet. Optimering av systemet ger vilka komponenter som skall användas vid olika tidpunkter för att uppfylla ett bestämt värmebehov och kylbehov. Resultatet i form av optimal drift under 2021 analyseras och används för att ta fram driftrekommendationer för energisystemet i framtiden. En metod för att teoretiskt begränsa marklagrets kapacitet vid optimering presenteras. Metodenanvänder nettoenergi till marklagret över en specifik tidsperiod för att approximera temperaturen på brinevätskan ut ur marklagret. Genom att sätta temperaturbegränsningar på brinevätskan kan därigenom nettoenergin till marklagret begränsas. Baserat på data från 2021 tillåts nettoenergin till marklagretvariera mellan -14 700 kWh och 12 500 kWh per 24 timmar. Resultaten visar att det under vintern är fördelaktigt att primärt använda bergvärmepumparna A-D i kombination med frikyla. Sekundärt används kylvärmepumparna E-F. Skillnaden mellan primär och sekundär systemlösning är liten och de båda kan ses som relativt likvärdiga. Fjärrvärme används enbart som sista alternativ under vintern. Energikällan för bergvärmepumparna bör variera mellan Klarälven och marklager med avsikt att utnyttja marklagrets kapacitet optimalt. Vår och höst fallet är till stora delar likvärdigt med vinterfallet med undantaget att det innehåller fler variationer till följd av förändringar i omgivande förutsättningar. Under sommaren bör enbart fjärrvärme användas för att tillgodose värmebehovet. Frikyla och kylmaskinerna 2-3 används för att tillgodose kylbehovet. Frikyla reserveras till att användas under de tidpunkter då kylbehovet är som högst. Effektavgiften för fjärrvärme står för 25,7 % av total driftkostnad i optimalt driftfall. För att minska kostnaderna anses det därför viktigt att kapa effekttopparna för fjärrvärme. Studien undersöker eventuella fördelar med att koppla frikyle-värmeväxlaren mot Klarälven med avsikt att kunna utnyttja den mer än vad som görs i dagsläget. Systemlösningen ger ingen signifikant minskning av driftkostnader vid simulering av ett års drift. Det kan dock vara fördelaktigt att koppla frikyla mot Klarälven ur perspektivet att kunna justera nettoenergin till marklagret för att förhindra långsiktiga temperaturförändringar i berggrunden. Årlig driftkostnad kan minskas genom att öka maxkapaciteten för värmepumparna. En ökning avbergvärmepumparnas kapacitet motsvarande en komponent minskar total årlig kostnad med 4,6 %. En ökning av kylvärmepumparnas kapacitet motsvarande en komponent minskar total årlig kostnad med 1,5 %. Att öka maxkapaciteten för övriga komponenter ger ingen signifikant förändring av årlig driftkostnad. Förbättring av studien innebär att basera modellen på bättre indata samt ta hänsyn till fler detaljer i systemet. Vidare studier bör fokusera på att tillämpa resultaten för att verifiera dem i verkligheten samt göra investeringskalkyler över att utöka kapaciteten för värmepumparna. / The study uses linear programming to optimize the operation of the thermal energy system at Karlstad Central Hospital from an economic perspective. The background to the study is the high electricity prices that occurred at the end of 2021 and the fact that there are currently knowledge gaps regarding how the system should be run optimally. The study is based on operational data from 2021. The energy system that is optimized is made up of cooling heat pumps, ground source heat pumps, cooling machines, free cooling, district heating and ground storage. A ratio for how many kWh of thermal energy that is produced per kWh of supplied electricity was produced for all components, which was then used to model the energy system. Optimization of the system provides which components are to be used at different times to meet a specific heating and cooling demand. The result in the form of optimal operation during 2021 is analyzed and used to produce operating recommendations for the energy system in the future. A method for theoretically limiting the capacity of the ground storage during optimization is presented. The method uses net energy to the ground storage over a specific period of time to approximate the temperature of the brine liquid out of the ground storage. By setting temperature limits on the brine liquid, the net energy to the ground storage can thereby be limited. Based on data from 2021, the net energy to the ground storage is allowed to vary between -14 700 kWh and 12 500 kWh per 24 hours. The results show that during the winter it is advantageous to primarily use the ground source heat pumps A-D in combination with free cooling. Secondary, the cooling heat pumps E-F are used. The difference between primary and secondary system solution is small and the two can be seen as relatively equivalent. District heating is only used as a last resort during the winter. The energy source for the ground source heat pumps should vary between the Klarälven river and the ground storage with the intention of utilizing the capacity of the ground storage optimally. The spring and autumn case is largely equivalent to the winter case, with the exception that it contains more variations as a result of changes in surrounding conditions. During the summer, only district heating should be used to meet the heat demand. Free cooling and cooling machines 2-3 are used to meet the cooling needs. Free cooling is reserved for use during the times when the cooling demand is at its highest.The power fee for district heating accounts for 25.7% of the total operating cost in the optimal operating case. To reduce costs, it is therefore considered important to cut the power peaks for district heating. The study examines the possible benefits of connecting the free cooling heat exchanger to the Klarälven river with the intention of being able to use it more than what is currently the case. The system solution does not provide a significant reduction in operating costs when simulating one year of operation. It might however be advantageous to connect free cooling to the Klarälven river from the perspective of being able to adjust the net energy to the ground storage to prevent long-term temperature changes in the bedrock. Annual operating costs can be reduced by increasing the maximum capacity of the heat pumps. An increase in the capacity of the ground source heat pumps equivalent to one component reduces the total annual cost by 4.6%. An increase in the capacity of the cooling heat pumps equivalent to one component reduces the total annual cost by 1.5%. Increasing the maximum capacity for the other components does not result in a significant change in annual operating costs. Improvements of the study means basing the model on better input data and taking into account more details in the system. Further studies should focus on applying the results to verify them in reality andmake investment calculations regarding expansion of the capacity of the heat pumps
16

Hydronic Pavement Systems for Sustainable Winter Road Maintenance in Sweden : A Study of Hamnbacken in Visby / Uppvärmda vägar för hållbar halkbekämpning i Sverige

Barikan, Chirin January 2019 (has links)
In countries with harsh winter climates extensive winter road maintenance is necessary to achieve traffic accessibility and road safety. These measures have high economic and environmental costs as snow free roads and winter road maintenance in Sweden today is achieved by a combination of mechanical snow clearance and the spreading of salt to prevent ice formation. The salt ends up in the roadside environment and has negative effects on groundwater and vegetation. An alternative to traditional winter road maintenance to obtain non-skid winter roads is the use of hydronic pavement(HP) systems. Existing HP systems in Sweden are powered by district heating which limits the application to urban locations. The goal is to utilize renewable energy sources such as geoenergy which can be used in both rural and urban locations. This thesis suggests Hamnbacken in Visby as a pilot project for a full-scale application of the proposed HP system using surface water source heat.The weather related road surface conditions on Hamnbacken, and the potential of a renewable energysource have been examined in this study and the proposed location has been found favourable for a HP system. / Länder med övervägande kallt vinterklimat är halkbekämpning en nödvändighet för trafikens framkomlighet och säkerhet. Åtgärderna som vidtas för att få snö- och isfria vägar är kostsamma samt har en hög miljöpåverkan, ett vedertagligt exempel är plogning och saltning. Saltet hamnar i slutändan inom vägens omgivande områden och har en negativ påverkan på grundvatten och vegetation. En alternativ lösning till traditionell halkbekämpning är uppvärmda vägar för att uppnå ett halkfritt vinterväglag. Befintliga väguppvärmningssystem i Sverige försörjs av fjärrvärme vilket är en begräsning då tillgången till fjärrvärme finns i anslutning till tätorter. Målet är att utnyttja förnybara energikällor såsom geoenergi som är tillgänglig både i tätorter och på landsbygden. Det här examensarbetet undersöker Hamnbacken i Visby som ett pilotprojekt för en fullskalig implementering av väguppvärmningssystem där sjövärme används som energikälla. Denna studie har undersökt väderrelaterade vägförhållanden på Hamnbacken samt potentialen för användning av sjövärme. Den föreslagna platsens förutsättningar har visat sig vara gynnsamma i detta avseende.
17

Temperaturzoner för lagring av värmeenergi i cirkulärt borrhålsfält / Temperature stratification of borehole thermal energy storages

Penttilä, Jens January 2013 (has links)
The thermal response of a borehole field is often described by non‐dimensional response factors called gfunctions.The g‐function was firstly generated as a numerical solution based on SBM (Superposition BoreholeModel). An analytical approach, the FLS (Finite Line Source), is also accepted for generating the g‐function. In thiswork the potential to numerically produce g‐functions is studied for circular borehole fields using the commercialsoftware COMSOL. The numerical method is flexible and allows the generation of g‐functions for any boreholefield geometry. The approach is partially validated by comparing the solution for a square borehole field containing36 boreholes (6x6) with g‐functions generated with the FLS approach and with the program EED (Earth EnergyDesigner). The latter is based on Eskilsons SBM, one of the first documents where the concept of g‐functions wasintroduced. Once the approach is validated, the square COMSOL model is compared with a circular geometryborehole field developed by the same method, consisting of 3 concentric rings having 6, 12, and 18 boreholes.Finally the influence on the circular geometry g‐function is studied when connecting the boreholes in radial zoneswith different thermal loads. / Den termiska responsen för ett borrhålsfält beskrivs ofta med den dimensionslösa responsfunktionen kallad gfunktion.Responsfunktionen togs först fram som en numerisk lösning med SBM (Superposition Borehole Model).En analytisk metod, FLS (Finite Line Source) är också accepterad för framtagandet av g‐funktioner. I det här arbetetundersöks förutsättningarna att numeriskt ta fram g‐funktioner för cirkulära borrhålsfält genom att använda detkommersiella simuleringsprogrammet COMSOL Multiphysics. Den numeriska metoden är flexibel och kananvändas för alla typer av borrhålsgeometrier. Metoden att använda COMSOL valideras delvis genom att jämföraresultatet för ett kvadratiskt borrhålsfält innehållande 36 borrhål (6x6) med lösningar framtagna med FLS och meddimensioneringsprogrammet EED (Earth Energy Designer). Det senare har sin grund i Eskilsons SBM, ett av deförsta arbeten där begreppet g‐funktion introducerades. När metoden att använda COMSOL verifierats, jämförsden kvadratiska borrhålsmodellen med en cirkulär borrhålskonfiguration, upprättad med samma metod,innehållande 3 koncentriska ringar om vardera 6, 12, 18 borrhål. Slutligen undersöks hur den termiska responsenpåverkas då borrhålen i ett cirkulärt borrhålsfält kopplas samman och grupperas i radiella zoner med olika termiskalaster. / SEEC Scandinavian Energy Efficiency Co.
18

LIST : Design för ett aktivitetsbaserat boende på mindre yta.

Toijanen, Annika January 2021 (has links)
ABSTRAKT  I mitt examensarbete vill jag utforska och skapa smarta lösningar som hjälper oss att leva och bo på ett mer aktivitetsbaserat sätt i framtiden. Ett boende där jag vill uppmuntra och förenkla för oss alla att bo på mindre yta och med fler flexibla platser och funktioner, både för miljöns skull men även för en mer solidarisk fördelning av den yta vi förfogar över idag.  Mindre boendeyta betyder även att allt vi fyller våra hem med behöver vara väl genomtänkta och funktionella. Så vad krävs då egentligen för att vi ska vilja släppa ifrån oss av vår yta? Och kan jag genom min design skapa en öppen och varm känsla på mindre yta utan att försaka estetik och bekvämlighet? Eller hur kan smarta lösningar få oss att välja att bo kvar i ett mindre boende även när vi blir fler i familjen, något som inte enbart gynnar miljön utan även den egna plånboken? De blir några av mina utgångspunkter i mitt utforskande. De metoder jag använder i min research är enkäter, intervjuer och egna observationer av min hemmiljö tillsammans med internetsökningar och texter om kompakta boenden, fällbara lösningar och minimalism.  Mina designbeslut tar jag med input från de svar jag får in och min målsättning är att ha minst en produktionsklar modell att visa upp vid Konstfacks vårutställning i maj 2021.
19

Performance evaluation of ground source heat pump heating systems in Stockholm

BÖRJESSON, MARCUS January 2020 (has links)
GSHP systems are common in Sweden but there are few evaluations quantifying the performance of the systems and highlighting problem that occurs during operations. The research project Annex 52 Long-term performance measurement of GSHP systems serving commercial, institutional and multifamily building part of IEA HPT TCP proves the need to systematically be able to evaluate GSHP systems. This thesis aims to expand the knowledge of how to evaluate GSHP systems and provide case studies for Annex 52. Three residential ground source heating systems used for heating has been evaluated and analyzed in this study. The evaluation has consisted of three parts. The first part analyzes the operation and stability of the GSHP systems. The second part consist of a detailed study of the performance of the GSHP systems. The seasonal performance factor has been calculated for different system boundaries based on the work done by SEPEMO. In addition, a method on how to evaluate the efficiency of the heat pumps based on the two temperature levels, source side temperature and the heat sink temperature, that the heat pump is operating at throughout a year has been developed within this thesis. This has included a method on how to normalize the temperatures based on the operation of the heat pump in order to quantify one temperature for each the two temperature levels. The third part consist of a comparison of the mean secondary fluid temperature between the calculated temperature using the software EED and the measured temperatures. This includes a comparison evaluation and sensitivity analysis on input parameters during the design of the borehole heat exchanger fields. This study has expanded the available reference cases of GSHP systems in Sweden. It also can be used as a guideline for those who will evaluate future GSHP systems. Designers of GSHP system will also benefit from the recommendations listed in this thesis regarding instrumentation and possible problems that may occur. The results show that the evaluation successfully managed to quantify the performance and operational issues that have occurred for each system. The method developed in this study was able to quantify the operation of the different systems based on the temperature levels and can be used for future GSHP evaluations of similar system type. / Bergvärmesystem är vanligt förekommande i Sverige men trots detta finns det få studier där prestandan har utvärderats och de vanligt förekommande problemen under drift har belysts. Forskningsprojektet Annex 52 Annex 52 Long-term performance measurement of GSHP systems serving commercial, institutional and multi-family building som är en del av IEA HPT TCP visar på behovet av att systematisk utvärdera bergvärmesystem. Detta examensarbete syftar till att utveckla och bidra till kunskap om hur bergvärmesystem kan utvärderas och att bidra med exempelstudier till Annex 52. Inom detta examensarbete har tre bergvärmesystem som betjänar flerbostadshus utvärderats och analyserats. Utvärderingen bestod av tre analyser. I den första analyserades driften av bergvärmesystemen och hur stabilt systemet har varit historiskt. Detta följdes av en detaljerad analys av olika nyckeltal för bergvärmesystemen. Årsverkningsgraden har beräknats för olika gränsdragningar vilka baseras på det tidigare arbetet utfört av SEPEMO. Inom detta examensarbete har även en metod tagits fram för att utvärdera verkningsgraderna för en värmepump baserat på de två temperaturnivåerna, köldbärarsidan och värmebärarsidan, som värmepumpen arbetar med under ett år. Till detta har en metod tagits fram om hur temperaturen kan normaliserats baserat på driften av värmepumparna för att kvantifiera en temperatur vardera för de två temperaturnivåerna. I den tredje utvärderingen jämfördes den beräknade medelfluidtemperaturen av köldbäraren i borrhålen med den uppmätta temperaturen. Till detta utfördes en känslighetsanalys av hur indata av dessa beräkningar påverkar resultaten.
20

Högtempererat borrhålslager för fjärrvärme / High Temperature Borehole Thermal Energy Storage for District Heating

Hallqvist, Karl January 2014 (has links)
The district heating load is seasonally dependent, with a low load during periods of high ambient temperature. Thermal energy storage (TES) has the potential to shift heating loads from winter to summer, thus reducing cost and environmental impact of District Heat production. In this study, a concept of high temperature borehole thermal energy storage (HT-BTES) together with a pellet heating plant for temperature boost, is presented and evaluated by its technical limitations, its ability to supply heat, its function within the district heating system, as well as its environmental impact and economic viability in Gothenburg, Sweden, a city with access to high quantities of waste heat. The concept has proven potentially environmentally friendly and potentially profitable if its design is balanced to achieve a good enough supply temperature from the HT-BTES. The size of the heat storage, the distance between boreholes and low borehole thermal resistance are key parameters to achieve high temperature. Profitability increases if a location with lower temperature demand, as well as risk of future shortage of supply, can be met. Feasibility also increases if existing pellet heating plant and district heating connection can be used and if lower rate of return on investment can be accepted. Access to HT-BTES in the district heating network enables greater flexibility and availability of production of District Heating, thereby facilitating readjustments to different strategies and policies. However, concerns for the durability of feasible borehole heat exchangers (BHE) exist in high temperature application. / Värmebehovet är starkt säsongsberoende, med låg last under perioder av högre omgivningstemperatur och hög last under perioder av lägre omgivningstemperaturer. I Göteborg finns en stor mängd spillvärme tillgängligt för fjärrvärmeproduktion sommartid när behovet av värme är lågt. Tillgång till säsongsvärmelager möjliggör att fjärrvärmeproduktion flyttas från vinterhalvår till sommarhalvår, vilket kan ge såväl lönsamhet som miljönytta. Borrhålsvärmelager är ett förhållandevis billigt sätt att lagra värme, och innebär att berggrunden värms upp under sommaren genom att varmt vatten flödar i borrhål, för att under vinterhalvåret användas genom att låta kallt vatten flöda i borrhålen och värmas upp. I traditionella borrhålsvärmelager används ofta värmepump för att höja värmelagrets urladdade temperatur, men på grund av höga temperaturkrav för fjärrvärme kan kostnaden för värmepump bli hög. I denna rapport föreslås ett system för att klara av att nå höga temperaturer till en lägre kostnad. Systemet består av ett borrhålsvärmelager anpassat för högre temperaturer (HT-BTES) samt pelletspannor för att spetsa lagrets utgående fluid för att nå hög temperatur. Syftet med rapporten är att undersöka potentialen för detta HT-BTES-system med avseende på dess tekniska begränsningar, förmåga till fjärrvärmeleverans, konsekvenser för fjärrvärmesystemet, samt lönsamhet och miljöpåverkan. För att garantera att inlagringen av värme inte är så stor att priset för inlagrad värme ökar väsentligt, utgår inlagringen från hur mycket värme som kyls bort i fjärrvärmenätet sommartid. I verkligheten finns betydligt mer värme tillgänglig till låg kostnad. När HT-BTES-systemet producerar fjärrvärme, ersätts fjärrvärmeproduktion från andra produktionsenheter, förutsatt att HT-BTES-systemets rörliga kostnader är lägre. I Göteborg ersätts främst naturgas från kraftvärme, men också en del flis. Kostnadsbesparingen beror på differensen för total fjärrvärmeproduktionskostnad med och utan HT-BTES-systemet. Undersökningen visar att besparingen är större om HT-BTES-systemet placeras i ett område där det är möjligt att mata ut fjärrvärme med lägre temperatur. Om urladdning från HT-BTES kan ske med hög temperatur ökar också besparingen. Detta sker om lagrets volym ökar, om avståndet mellan borrhål minskar eller om värmeöverföringen mellan det flödande vattnet i borrhålen och berggrunden ökar. Dessa egenskaper för lagret leder också till minskade koldioxidutsläpp. Storleken på besparingen beror dock i hög grad på hur bränslepriser utvecklas i framtiden. Strategiska fördelar med HT-BTES-systemet inkluderar; minskad miljöpåverkan, robust system med lång teknisk livslängd (för delar av HT-BTES-systemet), samt att inlagring av värme kan ske från många olika produktionsenheter. Dessutom kan positiva bieffekter identifieras. Undersökningen visar att HT-BTES-systemet har god potential att ge lönsamhet och minskad miljöpåverkan, och att anläggning och drift av lagret kan ske utan omfattande lokal miljöpåverkan. Det har också visats att de geologiska förutsättningarna för HT-BTES är goda på många platser i Göteborg, även om lokala förhållanden kan skilja sig åt. För att nå lönsamhet för HT-BTES-systemet krävs en avvägning på utformning av lagret för att nå hög urladdad temperatur utan att investeringskostnaden blir för stor. Undersökningen visar att om anslutning av HT-BTES-systemet kan ske mot befintlig anslutningspunkt eller till befintlig värmepanna kan investeringskostnaden minska och därmed lönsamheten öka. Placering av HT-BTES-systemet i områden med risk för överföringsbegränsningar kan också minska behovet av att förstärka fjärrvärmenätet, och således bidra till att minska de kostnader som förstärkning av nätet innebär. Betydelsefulla parametrar för att nå lönsamhet för HT-BTES-system inkluderar dessutom kostnaden för inlagrad värme liksom vilket vinstkrav som kan accepteras. Tillgång till HT-BTES möjliggör ökad nyttjandegrad och flexibilitet för fjärrvärmeproduktionsenheter, och därmed ökad anpassningsmöjlighet till förändrade förutsättningar på värmemarknaden. Dock återstår att visa att komponenter som klarar de höga temperaturkraven kan tillverkas till acceptabel kostnad.

Page generated in 1.2131 seconds