En undersökning av möjliga tillväxtmiljöer vid den tidiga sågverkshanteringen av ek / An investigation of posible growth environments for mould in the early sawmill handling of oak

Herdinius, Andreas January 2019 (has links)
Trä är ett biologiskt och organiskt material vars egenskaper möjliggör att det vid rätt förhållanden kan växa mögel på det. Mögeltillväxt på trä som människor hanterar och har i sin närhet kan skapa hälsoproblem då vissa mögelarter kan orsaka respiratoriska problem samt allergisk alveolit.En undersökning av vilken mögelsvamp som växer på brädor vid ett sågverk i södra Sverige har utförts. Utöver detta har möjliga tillväxtmiljöer för mögel undersökts under brädgårdstorkning samt en torkprocess. De undersökta parametrarna var temperatur och relativ luftfuktighet.Mögelsvampen Paecilomyces hittades samt Aspergillus niger och jäst. Klimatet under brädgårdstorkning samt torkprocessen visade att de under stor del av den tidiga hanteringen av virket fanns ett klimat gynnsamt för mögeltillväxt. / Wood is a biological and organic material whose properties makes it possible for mold to grow on it under the right conditions. Mold growth on wood that humans handle and get in contact with can create health problems as some mold species can cause respiratory problems and allergic alveolitis.An investigation of which mold that grows on boards at a sawmill in southern Sweden has ben carried out. In addition to this, possible growth environments for mold have been investigated during lumber yard drying and a kiln drying process. The parameters examined were temperature and relative humidity.Mold of Paecilomyces, Aspergillus niger and yeast was found on boards. The climate during lumber yard drying and the kiln drying process showed that a large part of the early handling of the wood had a favourable climate to mold growth.
22

Fuktförebyggande åtgärder för ett bättre klimat i den småländska stenkyrkans krypgrund / Moisture preventative actions, in order to ensure a better environment in the crawl space of thestonechurches of Småland

Ekelöf, Henrik, Hasselby, Fabian January 2010 (has links)
Fukt i kyrkans krypgrund är ett ”växande” problem som på senare tid uppmärksammats alltmer. I denna studie har flera möjliga lösningar undersökt, vidare har en allmän angreppsmodell formulerats för att underlätta framtida utredningar. Studien visar bland annat att styrning efter mögelrisken är önskvärt för att få ett energioptimerat och garanterat mögelfritt klimat. Åtgärdsförslag såsom sorptionsavfuktare samt värmning genom elradiator direkt i krypgrunden är möjliga lösningar som med ett litet energitillskott förbättrar klimatet i krypgrunden avsevärt.
23

Fuktstudie av en klimatvind på ett äldre småhus : En utredning av effekterna på vindsklimatet vid utvändig takisolering

Laiti, Pär-Henrik January 2017 (has links)
Mögelpåväxt orsakat av fuktproblem är vanligt förekommande på kallvindar i det svenska småhusbeståndet. Enligt en rapport från Boverket har var femte småhus en fuktskada på vinden orsakad av hög relativ fuktighet. Statistik från samma rapport visar att äldre hus med självdragsventilation är drabbade i större utsträckning. Luftläckage av fuktig inomhusluft till vind uppges vara en orsak bakom förhöjd luftfuktighet. Äldre hus är oftast inte lika lufttäta som moderna vilket gör dessa kallvindar mer utsatta. Att tilläggsisolera yttertaket utifrån har visat sig vara en åtgärd som sänker den relativa fuktigheten på kallvindar. Detta brukar kallas för att bygga om kallvinden till en klimatvind.   Denna studie baserar sig på en klimatvind på ett äldre småhus beläget i Skellefteå kommun. Den tidigare kallvinden var drabbad av fuktskador och byggdes därför om till en klimatvind 2014. Sedan dess har ingen utvärdering gjorts om detta är tillräckligt för att fuktsäkra vinden. Syftet med denna studie är därför att ta reda på om klimatvinden på detta hus är fuktsäker till följd av ombyggnaden. Resultatet kommer att användas som ett underlag för att besluta om fler åtgärder är nödvändiga för att fuktsäkra vinden.   För att bedöma fuktsäkerheten har mätningar av temperatur och relativ fuktighet på klimatvinden utförts. Under samma period utfördes även likadana mätningar på en traditionellt uppbyggd kallvind belägen 150 meter från klimatvinden. Genom att jämföra mätresultat mellan dessa vindar kan slutsatser om den utvändiga isoleringens effekt på vindsklimatet göras.   Resultatet av klimatmätningarna visar att den relativa fuktigheten på klimatvinden har legat långt under kritisk nivå för mögeltillväxt. Under samma mätperiod har relativ fuktighet på referensvinden varit i närheten av kritiska nivåer. Klimatvinden har i jämförelse med referensvinden ett varmare och torrare klimat och påverkas inte i lika stor utsträckning av svängningarna i utomhusklimatet. Slutsatsen är att klimatvinden anses vara fuktsäker under mätperioden. Rekommendationen är att fortsätta med klimatmätningar under en helårsperiod för att kunna bedöma fuktsäkerheten ur ett helårsperspektiv. / Mold growth caused by moisture are common in cold attics in small houses in Sweden. According to a report from the National Board of Housing - Boverket, a fifth of all attics in small houses in sweden has moisture problems caused by increased levels of relative humidity. Statistics from the same report show that older houses with natural draft ventilation are affected to a greater extent. Air leakage of damp indoor air into the attic space is said to be one cause of increased humidity. The construction of older houses are usually not as airtight compared to modern houses. This makes the attics in old houses more vulnerable to this problem. Additionally insulation with eps insulation at the outside of the roof has been shown to reduce the relative humidity in cold attics. This report refers to attics with this type of construction as a ”climate attic”   This study is based on a climate attic of a older house located in Skellefteå municipality. The former cold attic had mold problems caused by moisture and was therefore converted to a climate attic in 2014. Since then, no evaluation has been made of the moisture saftey in this climate attic. The purpose of this study is therefore to find out if the climate attic in this house is moisture safe due to the conversion. The results will be used to determining whether more actions are necessary to make the attic moisture safe.   In order to evaluate the moisture safety in the climate attic, measurements of temperature and relative humidity has been made. During the same period measurements were made in a traditionally cold attic. By comparing measurement results between those attics conclusions of the effect from the external isolation can be made. The results from the measurements made in the climate attic shows that the relative humidity has been far below critical levels for mold growth. During the same period the relative humidity in the traditional cold attic has been close to critical levels. In comparison with the traditionally cold attic, the climate attic has a warmer and drier climate and is not affected to the same extent by the fluctuations in the outdoor climate. The conclusion is that the climate attic are considered to be moistureproof during the time measurement was made. The recommendation is to continue with climate measurements over a full-year period to assess moisture safety from a full-year perspective. / <p>Kull H14</p>
24

Klimatanalys av två kulturhus : Med hjälp av relativ fuktighet och temperatur analysera och beräkna mögeltillväxt.

Karlsson, Rebecca January 2019 (has links)
Hullgrensgården och den Harbergska gården är två kulturhus på Smålands östkust, de båda kulturhusen är ouppvärmda vilket har medfört en oro för mögeltillväxt. Sedan 2011 har loggningar av luftens relativa fuktighet och temperatur gjorts på samtliga våningar i de båda kulturhusen. Diagram som redovisar hur den relativa fuktigheten förhåller sig under de fyra år som analyserats (2015-2019), visar att krypgrunden i Hullgrensgården samt de båda vindarna har en kritisk relativ fuktighet en stor del av mätperioden. En mögeldosmodell gjordes på dessa platser, vilken visade att det fanns risk för mögel på samtliga platser. Mikrobiella prov från sex platser skickades inför analys till botaniska analysgruppen. Resultatet visade en riklig frekvens av mögel på de båda vindarna samt i krypgrunden.
25

Mould resistance design for external wood frame wall systems : Simulation and evaluation of wall structures under varying conditions of exposure using the MRD model / Mögelresistensdimensionering för träregelkonstruktioner i ytterväggar : Simulering och utvärdering av ytterväggar under varierande exponeringsförhållanden med MRD-modellen

Dahlström, Carl, Giesen, Emma January 2015 (has links)
Moisture induced damages to building envelopes can result in microbial growth possibly affecting the health and wellbeing of occupants. Recent failing structures and damaged buildings indicate a lack of tools to estimate risk of mould growth and moisture damage. In this work a so-called mould resistance design (MRD) model has been applied for mapping the risk for mould growth on a number of wood-containing wall structures. The MRD model introduces an engineering approach to moisture safety design in a similar way as for structural design, where load and resistance is compared. The MRD model introduces and quantifies the concepts of climatic exposure and material resistance and compares them through an MRD index. This MRD index incorporates a limit state, which gives the critical dose of exposure for a given resistance to initiate onset of mould growth.   Three conceptual wall structures were evaluated and analyzed in terms of MRD index: two wall systems with an air gap and one wall system without. A parametric study investigating the effect of parameter variation on MRD index was conducted. Evaluated parameters were: climate (geographic location), orientation, air changes per hour in the air gap, driving rain penetrating the facade layer, exterior plaster properties and wood type. The simulations were performed using the hygrothermal calculation software WUFI. The results indicate that the wall systems with a ventilated air gap performs better in terms of MRD index i.e. suggests a lower risk of initiation of mould growth than the wall system without air gap. The results of orientation variation show that wall systems perform differently dependent on layering structure. The inherent water sorption properties of the exterior plaster are shown to have a large effect on the results. In addition, uncertainties were found on how to accurately include hydrophobicity as a parameter in the model. The report concludes that geographical location and its specific climate is the most important parameter to consider when designing for moisture safety. The MRD model is recommended to be used in combination with traditional moisture safety evaluation.
26

Effektivare utomhuslogistik inom träindustrin

Milena Björkholm, Sandra, Sköld, Sandra January 2023 (has links)
The outdoor logistics in wood industry is an interesting research area since many factors need to be taken into consideration for an efficient process. However, little research can be found specifically in term of the outdoor logistics within wood industry. The purpose of this study is to design a model for streamlining outdoor logistics in the wood industry. Additionally, what important factors for more efficient outdoor logistics are also to be investigated.  According to Institute for Transport Research (2002), the material handling is defined as all physical handling, movement, storage and packaging of materials. To make the study scope clear, the outdoor logistics is specifically defined as the outdoor material handling in this study, and the outdoor refers to the local area outside the production buildings. A major part of this investigation work has been performed at one case company called Valbo Trä. The research is done through literature review, interviews, site observations at case company, and has generated a broad and deep understanding of the operations at the case company and the theoretical basis for the model development.  This study shows that the demand for different products is very different as well as the lengths and quantities of the products. Such fluctuating demand generally occurs in the wood industry, not only at the case company. The unpredictability of the demand for raw materials makes it complex for the case company to meet the customer's demands for finished products. On the other hand, the material handling becomes complex when the inventory levels increase. The inventory levels create, among other things, tied up capital, obsolescence, tighter handling space and poorer visibility for the truck drivers. Obsolescence that occurs can be traced to material handling. Damage occurs during internal transport and the wood suffers from damage due to weather conditions during outdoor handling. When handling materials outdoors, there are also risks in the form of obscured visibility during transport with loaders. Violation of speed limits and varying compliance with safety rules also occur. High inventory levels also affect the possibility of applying FIFO. Flows, obsolescence, and safety have been identified as the most important factors for more efficient outdoor logistics within the wood industry. Based on the identified factors a model could be designed and applicable within the wood industry.
27

Moisture risks with CLT-panels subjected to outdoor climate during construction : focus on mould and wetting processes / Fuktrisker på KL-trä som utsätts för yttre klimat under produktion : fokus på mögel och uppfuktning

Öberg, Johan, Wiege, Erik January 2018 (has links)
When going through relevant research, moisture safety guidelines and talking to builders, moisture experts and architects it is clear - and not surprising - that water and wood make no easy combination. The experiences from building with cross laminated timber (CLT) differ from building sites and there are good and bad examples building without weather protection. In this study the moisture influence on CLT is analyzed. CLT is a type of massive wood with glued lamellas, increasing usage worldwide as structural elements in buildings. The bulk of the work is performed in the hygrothermal calculation tool WUFI(™). Focus is on the wetting process and the evaluation of mould risk from rain loads during production in Nordic climates. Subsequent drying after built into walls and floors is also evaluated. A vast literature survey is performed in order to compare and select material data for modelling CLT. Following the simulation work, moisture content, mould growth and volumetric distortion are judged both with and without weather protection. Results are also compared to measurement data from field tests. It is found that short building times are crucial, some weather protection is required all year around and early planning and constructing for moisture safety are crucial. The benefits of prefabrication and short building times using CLT should be exploited. If there is a risk of rainfall exceeding 10-20 mm, arrangements to divert rain loads should be undertaken. If the expected rain loads are above 40 mm or if the building time exceeds 2 weeks, a roof cover will be required. At air humidities averaging 80% and yearly rain exceeding 1200 mm, a complete building cover is recommended. A controlled environment may be expensive, but it speeds up production and shortens drying time. / När man går igenom relevant forskning, riktlinjer för fuktsäkerhet och pratar med byggare, fuktexperter och arkitekter är det tydligt - och inte överraskande - att vatten och trä inte är någon enkel kombination. Erfarenheterna från att bygga med korslimmat trä (KL-trä) skiljer sig från byggarbetsplatser och det finns bra och dåliga exempel från byggande utan väderskydd. I denna studie analyseras fuktpåverkan på KL-trä. KL-trä är en typ av massivt trä med limmade lameller, som ökar i användningen över hela världen som strukturella element i byggnader. Huvuddelen av arbetet utförs i det hygrotermiska beräkningsverktyget WUFI (™). Fokus ligger på uppfuktning och utvärdering av mögelrisker från regnbelastning under produktion i nordiskt klimat. Efterföljande torkning efter inbyggnad i väggar och golv utvärderas också. En omfattande litteraturstudie utförs för att jämföra och välja materialdata för modellering av KL-trä. Efter simuleringsarbetet bedöms fuktinnehåll, mögeltillväxt och fuktrörelser både med och utan väderskydd. Resultaten jämförs också med mätdata från fältförsök. Det konstateras att korta byggtider är avgörande, någon form av väderskydd krävs året runt och tidig planering och konstruktion för fuktsäkerhet är avgörande. Fördelarna med prefabricering och korta byggtider med KL-trä bör utnyttjas. Om det finns risk för nederbörd över 10-20 mm bör åtgärder vidtas för att avleda regn. Om de förväntade regnbelastningarna är över 40 mm eller om byggtiden överstiger 2 veckor krävs ett regnskydd. Vid luftfuktigheter på i medeltal 80 % och årligt regn över 1200 mm rekommenderas ett väderskydd runt hela byggnaden. En kontrollerad miljö kan vara dyr, men det påskyndar produktionen och förkortar torkningstiden.
28

Risk för fuktskador på vinden vid byte av uppvärmningssystem : En studie om småhus från 1960-talet, där vindsutrymmet granskas med hjälp av simuleringsprogrammen WUFI pro 6.2 och WUFI Mould Index

Foghammar, Jacob, Boudrie Hesselgren, Björn January 2019 (has links)
Dagens miljömedvetna samhälle ställer allt högre krav på minskade utsläpp av fossila bränslen. Detta är en bidragande faktor till att många hushåll under 2000-talet valt att byta ut sina värmepannor med intern förbränning (olja, ved, koks, pellets och flis) till fördel för alternativa värmesystem. I statistik från MSB (2017) framgår att cirka 15 % av landets drygt 2 miljoner småhus år 2016 hade intern förbränning som uppvärmningssystem. De positiva effekterna av ett byte från ett internt förbränningssystem till ett av de alternativa värmesystemen, exempelvis berg- eller fjärrvärme, är väl studerade och dokumenterade. Sådana positiva effekter är bland annat minskade utsläpp av växthusgaser samt de kostnadsbesparingar ett byte av värmesystem medför för den enskilde fastighetsägaren. Någonting som saknas när det kommer till byte av värmesystem är dock studier av de byggnadstekniska risker ett byte medför.   Denna rapport ämnar att undersöka och analysera vilka risker som uppstår vid en modernisering av värmesystemet i ett tidstypiskt 1960-talshus. För att avgränsa rapporten görs en ytlig genomgång av risker som uppstår i byggnaden vid ett byte av värmesystem och fokus läggs sedan på hur vindsutrymmet i huset påverkas. Syftet med rapporten är således att besvara;   • Hur påverkas vinden i ett småhus från 1960-talet vid byte av uppvärmningssystem där intern förbränning byts ut?   Rapporten baseras på litteraturstudier och risksimuleringar i datorprogrammen WUFI pro 6.2 och WUFI Mould Index. I slutsatsen konstateras att risk kan förekomma för mikrobiell påväxt i vindsutrymmet om det interna förbränningssystemet byts ut och inga ytterligare åtgärder utförs för att anpassa huset till ett nytt värmesystem. För att begränsa risken för eventuella fuktskador som kan uppkomma efter ett byte från internt förbränningssystem ges följande rekommendationer; • Övervaka klimatet på vinden • Försäkra att ventilationen i bostaden förblir i god funktion • Byt eller täta vindsluckan • Isolera ovanpå råsponten • Installera sorptionsavfuktare på vinden • Om möjligt, elda i öppna spisen
29

Inneklimatet på Skoklosters slott : en studie av ett klimatexperiments första år

Justin Moll, Adam January 2014 (has links)
Inneklimatet på Skoklosters slott är på vissa håll problematiskt. Mögelangrepp förekommer i somliga rum, främst sådana som är belägna i norrläge och därmed lite kallare än övriga rum. För att finna en lösning på mögelproblemen inleddes våren 2013 ett treårigt experiment vars syfte var att utröna om mögelproblemen skulle kunna undvikas med aktiv klimatstyrning, vilket inte funnits innan experimentet. Tre olika klimatstyrningsanläggningar installerades i tre rum på slottet, samtidigt som mätningar gjordes i referensrum utan aktiva åtgärder. De tre klimatstyrningsanläggningarna som valdes ut var avfuktning, skyddsvärme och fuktstyrd ventilation. I mars 2014 avslutades första året av experimentet.Ur mögelrisksynpunkt har inneklimatet i nästan alla rum, både försöks- och referensrum, varit relativt godartat. Sämst inneklimat uppmättes i skyddsvärmerummet, vilket förmodligen beror på rummets egna förutsättningar snarare än skyddsvärmen. Bäst inneklimat hade rummet med den fuktstyrda ventilationen, som gav ett oväntat bra resultat och dessutom var den av klimatstyrningsanläggningarna som var mest i bruk. Det är emellertid för tidigt att med säkerhet säga vilken av anläggningarna som vore bäst för slottet.Vid en diskussion om de antikvariska konsekvenserna av en genomgripande installation av en klimatstyrninganläggning blev slutsatsen att det för slottets kulturhistoriska värde vore gynnsamt att göra en genomgripande installation ifall detta skulle innebära att slottets samlingar kunde behållas på plats. Rummens olika fysiska och kulturhistoriska förutsättningar kräver dock att individuella utformningar undersöks, vilket innebär att det kan bli aktuellt med en kombination av olika klimatstyrningsanläggningar. / The indoor climate of Skokloster palace is not without problems. There have been mould growth in some rooms, mainly those who are facing north and therefore are colder than other rooms. To find a solution for the problems with mould growth, a three-year long experiment was initiated in the spring of 2013. Its purpose was to examine if mould growth could be avoided with active climate control, which had not been tested previously in the palace. Three different climate control systems were installed in three rooms, and meanwhile the indoor climate of three rooms without active climate control was logged. The three climate control systems chosen were dehumidification, conservation heating, and humidity controlled ventilation. The first year of the experiment ended in March 2014.The climate in nearly all rooms was acceptable in a mould risk perspective. The room with conservation heating had the least suitable climate, which probably is explained by the condition of the room itself rather than the effects of the conservation heating. The room with humidity controlled ventilation hade the best climate during the year, and the ventilation system had the most uptime of the climate control systems. It is however too early to tell which system might be the best after only one year.When discussing what consequences a thorough installation of a climate control system might have on the cultural heritage values of Skokloster palace, the conclusion was that it would be favourable to install active climate control – if that allowed the collections of Skokloster to remain in the building. Due to the different physical and cultural conditions of the palace’s rooms, it will be necessary to find tailored solutions for climate control systems. In order to do that, a combination of different climate control systems might be worth looking into. / Spara och bevara - Energimyndighetens forskningsprogram för energieffektivisering i kulturhistoriskt värdefulla byggnader
30

Problem i högt fuktbelastade byggnader : Riskbedömning med hjälp av WUFI / Problems in buildings with high moisture load : Risk assessment using WUFI

Wong, Katilla, Bergh, David January 2012 (has links)
Många av Sveriges badhus byggda i slutet av 1900-talet börjar idag visa tecken på kraftiga fuktskador på grund av extrema inomhusklimat. Denna rapport förklarar den allmänna problematiken kring högt fuktbelastade byggnader och berör det fuktskadade badhuset Aquarena i Katrineholm.  Extrem noggrannhet krävs vid montering av ångspärr i en konstruktion, speciellt vid högt invändigt fukttillskott. Optimal placering av fuktspärren i konstruktionens varmare del innebär att fukt aldrig tillåts kondensera och därmed minimeras risken för fuktskador och negativa konsekvenser. Verkligheten visar också att om kunskaper om fukt och fuktskador prioriteras redan i ett tidigt stadium under projektering kan många hundratusentals kronor sparas. Beräkningar av fukttransport har gjorts för tidigare ytterväggskonstruktion i Aquarena (den som drabbats av skador) och nybyggd ytterväggskonstruktion (nyframtagen till återuppbyggnaden) i datorprogrammet WUFI Pro 4.2 och analyserats i WUFI Bio 3.0.  Beräkningarna visar att den tidigare väggkonstruktionen får de skador som undersökningar av den visat och att skadorna hade kunnat undgås om genomförningar i ångspärren hade utförts på ett korrekt sätt.  Vi har med beräkningar inte kunnat bevisa att alla delar i den nybyggda ytterväggskonstruktionen kommer fungera perfekt. Främst beror osäkerheten i beräkningar utförda i WUFI på att beräkningsmodellen inte är färdigutvecklad. Osäkerheter beror också på otillräcklig kännedom av egenskaper hos de simulerade materialen. Beräkningar för den nyframtagna väggkonstruktionen visar dock entydigt på bättre resultat än för den tidigare väggkonstruktionen. Det finns därför anledning att vidare utreda vilka värden på fukt och temperatur som kommer att råda över de närmaste åren. Detta bland annat för att senare kunna korrigera beräkningsmodellen efter verkligheten. / Many of Sweden's public indoor swimming pools built in the late 1900’s are beginning to show signs of excessive moisture damage due to extreme indoor climate. This report explains the general problem of high moisture-loaded buildings and involves the moisture-damaged public indoor swimming pool Aquarena in Katrineholm. Extreme care is required when assembling the moisture barrier in a structure, especially with high internal moisture content. Optimal placement of the moisture barrier in the warmer parts of the construction means that moisture is never allowed to condense, thus minimizing the risk of moisture damage and negative consequences. Reality also shows that if risks of moisture and moisture damages are assessed early in the planning process, amounts in the range of hundreds of thousands of Swedish crowns can be saved. Calculations of moisture transport have been made for the previous exterior wall structure (the one that suffered damage) and new exterior wall structure the (new design for the reconstruction) using the computer program WUFI Pro 4.2 and analyzed in WUFI Bio 3.0. Calculations show that the old exterior wall structure in Aquarena would have been able to withstand moisture damage and damages due to moisture if joints and transitions in the moisture barrier had been correctly performed.  Calculations have not proven that all elements of the newly built wall design will work perfectly. The main reason for uncertainty in calculations when using WUFI is that the calculation model is not fully developed. Uncertainty is also due to insufficient knowledge of properties of the simulated materials. However, calculations show unambiguously better results than the previous wall construction. It is therefore necessary to further investigate what values of humidity and temperature will exist over the next few years to be able to later on correct the calculation model after reality.