• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • Tagged with
  • 40
  • 19
  • 17
  • 16
  • 11
  • 11
  • 9
  • 9
  • 9
  • 9
  • 8
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Tilläggsisolering inom byggnadsvård

Hultberg, Ann-Charlotte, Larsson, Emelie January 2009 (has links)
Främsta anledningen till en tilläggsisolering är att det önskas bättre energihushållning i en byggnad. Detta kan göras med olika material och olika tekniker. Inom byggnadsvårdssammanhang förs det en diskussion om de fuktbuffrande materialen är bättre vid tilläggsisolering då de är hygroskopiska än de icke hygroskopiska som är mest frekvent använda i det konventionella byggandet. Denna rapport utvärderar om det finns några dokumenterade fakta som styrker att de hygroskopiska och ekologiska materialen fungerar bättre i byggnadsvårdssammanhang än de icke hygroskopiska. Olika isolermaterial från de två nämnda grupperna jämförs utifrån olika parametrar. / This report evaluates if there are any known facts that support that the hygroscopic and ecologic materials are better in supplement insulation than non hygroscopic. Different kind of insulate materials from these two mentioned groups are compared from without different kind of parameters.
22

Effekter vid tilläggsisolering av kallvindar ur fuktsynpunkt / Moisture effects of additional insulation in cold attics

Schill, Elin, Flodins, Tina January 2015 (has links)
Ekonomiska aspekter och krav på minskad energianvändning leder bland annat till tilläggsisolering av vindsbjälklag och byte av uppvärmningssystem. Åtgärderna ger ett kallare och fuktigare klimat på vinden vilket gynnar mögeltillväxt. Minst 60 % av alla traditionella vindar med självdrag kan anses ha riklig tillväxt av mögelsvamp (Ahrenens och Borglund 2007). Syftet med denna studie är att ta ett steg i rätt riktning om vilka åtgärder som kan göras på de vindar som idag är angripna. I denna studie har tre vindars fukttillstånd utretts och jämförts. Ett av objekten har simulerats och utsatts för olika åtgärder. Simuleringarna bekräftar att minskad isolering ger ett torrare klimat på vinden. En ökning av ventilationen ger liten men knappt märkbar förbättring av vindsklimatet. Hög värmekapacitivitet hos isoleringsmaterial verkar ge en jämnare temperatur på vinden vilket sänker luftfuktigheten. Genom att isolera vindens tak och gavlar sker en markant sänkning av mögelrisken. Då varje vind är olika uppbyggd finns ingen generell lösning utan varje vind måste bedömas utifrån sina nuvarande förhållanden.
23

Minskad energianvändning och klimatpåverkan : En fallstudie av Preems kontor i Skarvikshamnen / Reduced energy use and climate impact for Preems office building in Skarvikshamnen

Carlsson, Johanna January 2020 (has links)
Preem has recently acquired a new office building and are interested inreducing the energy consumption, climate impact and annual energy costof the building. The purpose of this thesis is to examine how differentenergy efficiency measures as well as the installation of solar cellsaffect the energy use and climate impact of an office building. Three actions have been proposed, both separately and in combinationwith each other. These were attic insulation, change of ventilation andchange of heating system. The resulting simulations showed a reductionof between 3 and 65 %, depending on which energy efficiency measureswere implemented. Replacing the heating system resulted in the largestreduction. This study also showed that the most profitable way to place a PVsystem is in a south-westerly direction with a 25 degree slope. Thissolution has an installed power of 16.3 kWp and an annual electricityproduction of 12.96 MWh. This corresponds to a self-consumption rate of95.2 % and a self-sufficiency rate of 5.6 %. The highest electricityproduction was obtained when PV modules were placed on three differentrooftops and with a module slope of between 12 and 15 degrees,depending on the roof. This PV system has an installed power of 76.9kWp and an annual electricity production of 57.96 MWh. All solutionsled to a reduced climate impact.
24

Jämförelsestudie av tilläggsisolering / Comparative study of additional insulation

Elmi, Said, Eskilsson, Christoffer January 2013 (has links)
Rapporten behandlar och utvärderar tre olika isolermaterial, Polyisocyanurat (PIR), grafitcellplast och mineralull, vid tilläggsisolering av miljonprogrammets byggnationer.  Stora delar av miljonprogrammet är nu i behov av upprustning. Samhällets skärpta krav gällande energiförbrukning gör att nya rationella metoder och material krävs för att tillgodose ställda krav. Att tilläggsisolera är en del i denna upprustning, och eftersom valet av isolermaterial ofta faller på gamla beprövade metoder och materialval, såsom mineralull, syftar denna rapport till att öka kunskapen om alternativa, mer högpresterande isolermaterial. Isolermaterialens egenskaper tas först upp och behandlas i en generell jämförelse där ekonomiska och tekniska aspekter beaktas. För att konkretisera och påvisa utfallet i ett specifikt fall genomförs en studie för ett referensprojekt, kvarteret Hundlokan, som ägs och förvaltas av Fastighets AB Förvaltaren. I studien undersöks tre olika alternativ för vart och ett av materialen vid tilläggsisolering utvändigt av Hundlokans fasader. Samtliga alternativ ställs sedan mot varandra och utvärderas med hjälp av: fukt-, U-värdes-, energi-, kostnads- och LCC-beräkningar (livscykelkostnad). Enklare fuktberäkningar som påvisar relativ fuktighet (RF), ånghalt och temperatur i väggens olika skikt genomförs. Resultatet visar att alla alternativ anses vara möjliga att tillämpa utan att fuktproblem ska behöva uppstå. Mer avancerade beräkningar bör genomföras vid projektering. Energiberäkningarna för de olika alternativen och även ursprungsfallet görs i ”VIP-energy” för att möjliggöra en realistisk jämförelse där skillnaderna i transmissionsförluster ställs mot varandra. I kostnadsberäkningarna påvisas skillnaderna i produktionskostnaderna för de olika alternativen. Dessa tillsammans med energibesparingen i form av minskade transmissionsförluster ligger sedan till grund för LCC-beräkningarna. Då stora ytor av fasaden i kv. Hundlokan upptas av fönster och indragna balkonger som skapar köldbryggor görs med ökad isolertjocklek ingen stor energibesparing i form av minskade transmissionsförluster. Initialkostnaderna för de tjockare isoleralternativen blir för höga för att möjliggöra återbetalning inom rimlig tidsram. Slutsatsen blir att tilläggsisolering med alternativa material till mineralull kan vara lönsamt och bör alltid undersökas i ombyggnadsprojekt. I det specifika fallet kvarteret Hundlokan är tilläggsisolering med 10 cm PIR det mest lönsamma alternativet. / This report treats and evaluates three different types of insulation materials: Polyisocyanurate (PIR), graphite foam and mineral wool, at additional insulation of houses from the Swedish “millionprogram”. Large parts of the houses from the millionprogram are now in need of restoration. The stricter rules laid down by the society regarding the use of energy, demands new, rational methods and materials to satisfy the regulations. Additional insulation is a step in meeting the energy regulatory requirements, and since the choice of insulation often is limited to traditional out tried methods and choices of materials, such as mineral wool, this report will explore the alternative, high-performance insulation materials. The insulation material’s qualities will be treated in a general comparisment where economical and technical aspects will be covered. In order to concretize and demonstrate the outcome in a specific case, a case study will be executed for the neighborhood Hundlokan owned and managed by Fastighets AB Förvaltaren. In the case study, three different alternatives will be examined, for each and every material at the additional insulation, outwardly at Hundlokan’s facades. All these alternatives are compared with each other and evaluated with regards to moister, u-value, energy, costs and LCC- calculations (Life cycle analysis). Simpler moisture calculations are implemented demonstrating the relative humidity (RF), steam level and temperature in the walls different layers. The results of the moisture calculations demonstrate that all alternatives seem possible to apply without the risk of the occurrence of any moisture problems. But more advanced moisture calculations are recommended to be carried out for restoration projects. Energy calculations regarding the different alternatives and the current state will be performed with “VIP-energy” in order to enable a realistic comparisment between the differences at transmission losses. Differences are shown within the cost’s calculations in production costs for the different alternatives. These along together with the energy savings in terms of less transmission losses are bases for the LCC-calculations. A large surface of the facade is covered by windows and recessed balconies which create thermal bridges, increased thickness of the isolation results in no larger energy savings in terms of decreased transmission losses.  The initial costs for the thicker isolation alternatives will be high in order to enable repayment within a reasonable time frame. The conclusion is that adding insulation with alternative materials than mineral wool can be profitable and should always be examined in reconstruction projects. For the specific case, Hundlokan additional insulation with 10 cm PIR is the most profitable option.
25

Miljöpåverkan för invändig tilläggsisolering : Osäkerheter kopplat till LCA med verktyget RIBuild / Environmental impact for internal insulation : Uncertainties linked to LCA with the tool RIBuild

Sjöblom, Ellinor, Sundin, Alexandra January 2021 (has links)
In today’s Europe, one third of all buildings are classed as historic buildings, with three quartersof these being graded as energy inefficient. This means that there is a great potential to implementmeasures of energy efficiency while keeping the cultural value in mind. One way to reduceenvironmental impact, with respect to cultural values is according to studies to install internalinsulation. In order to calculate the environmental impact for internal insulation for the entirety ofits life cycle, a life cycle assessment can be used. It can also estimate the improvements in anenvironmental perspective when installing internal insulation. On an initiative from the EU commission, a team of researchers have developed a software called RIBuild – WP5 Software Tool with the purpose of making life cycle assessments in order to determine the environmental impact of internal insulation. The Software Tool is based on a probabilistic method which identifies uncertainties within the life cycle assessments. Therefore, the software is considered to bring something new to the field of life cycle assessments for internal insulation in historic buildings. This study means to evaluate and assess whether or not RIBuild can demonstrate the uncertainties that are linked to life cycle assessments for internal thermalinsulation in historic buildings in an accurate manner. In order to be able to analyze whether the result is reliable in regard to uncertainties, thestandardized framework for life cycle assessments SS-EN ISO 14040:2006, as well as formerstudies on RIBuild, formed the basis for the study’s method and implementation. The resultsproved that with the usage of RIBuild it is possible to detect differences in uncertainties linked tolife cycle assessments between two internal thermal insulations. It is also possible to determinewhich one of these two insulations that are best suited to make the historic buildings more energyefficient. However, it is uncertain if RIBuild can be used to show uncertainties linked to life cycleassessment in internal thermal insulation without a comparison study. This is due to the fact thatRIBuild does not consider actual sources of errors and uncertainties when calculating a life cycleassessment without a comparative study. / I dagsläget är en tredjedel av alla byggnader i Europa historiska byggnader, varav tre fjärdedelar av dessa kan anses vara energiineffektiva. Detta gör att det finns en stor potential att implementera energieffektiviseringsåtgärder som samtidigt beaktar byggnadens kulturvärde. Ett sätt att minska miljöpåverkan samt energianvändningen men samtidigt bevara kulturvärdena hos historiska byggnader är enligt studier att installera invändig tilläggsisolering. För att kunna beräkna den invändiga tilläggsisoleringens miljöpåverkan under hela livscykeln samt uppskatta effekten av installationen kan livscykelanalyser användas. Ett forskarteam utifrån ett initiativ av EU-kommissionen har därav tagit fram programvaran RIBuild - WP5 Software Tool i syfte att kunna fastställa invändig tilläggsisolerings miljöpåverkan med hjälp av livscykelanalyser. Verktyget baseras på en probabilistisk metod som inkluderar osäkerheter i LCA-framtagningen vilket kan anses tillföra något nytt inom området för livscykelanalyser för invändig tilläggsisolering av historiska byggnader. Denna studie syftar till att studera och utvärdera om RIBuild kan påvisa de osäkerheter som finns länkat till livscykelanalys för invändig tilläggsisolering hos historiska byggnader på ett tillförlitligt sätt. För att ha möjligheten att analysera huruvida resultatet är tillförlitligt länkat till osäkerheter har det standardiserade ramverket för livscykelanalyser SS-EN ISO 14040:2006 och tidigare studier om RIBuild legat till grund för studiens metod och genomförande. Resultatet visade att man med hjälp av RIBuild kan påvisa skillnader i osäkerheter kopplade till livscykelanalyser mellan två tilläggsisoleringar. Det går även att få fram vilken av dessa två tilläggsisoleringar som är bäst lämpade för energieffektivisering av historiska byggnader. Däremot är det otydligt om man kan påvisa osäkerheter kopplat till livscykelanalyser vid invändig tilläggsisolering med hjälp av RIBuild utan en jämförande studie. Detta grundar sig i att RIBuild inte tar hänsyn till faktiska felkällor och osäkerheter vid framtagning av livscykelanalyser. Vilket resulterar i att man kan ifrågasätta RIBuilds trovärdighet kring huruvida de osäkerheterna som är kopplade till livscykelanalys faktiskt är korrekta.
26

ENERGIEFFEKTIVISERING AV ÄLDRE SMÅHUS : FASTIGHETEN LÅDBERGA 1:78 I KUNGSÖRS KOMMUN

Wennberg, Amanda, Östman, Cindy, Bergman, Kevin January 2019 (has links)
Through calculations as well as a literature study the purpose of this work was to apply modern energy efficiency measures on an old existing building and on the same time take economical aspects and thermal inside climate into account. The work also carries out a case study on the existing building Lådberga 1:78. The calculations that has been carried out acknowledges a change of the building’s thermal transmittance for each measure that has been simulated as well as a change of the buildings active heating. In order to carry out the comparison between the buildings active heating, before and after applying the modern building measures, the buildings current energy consumption was calculated.  To examine the proposed actions from an economical point of view, the payback method was used. When applying actions that include additional interior insulation, diffusion calculations was used. The energy efficiency action that was calculated to be most financially viable for the building was exchange of the heat system. This action included a change from an existing pellet boiler to a more efficient geothermal heat pump as well as the exchange of four radiators.  The second-best alternative was to add insulation to the attic. Also, one simple yet effective action that could be done in the building to improve the thermal inside climate was to mount sealing stripes around the existing windows. The energy efficiency actions that was found to be least financially viable was exchange of windows, doors as well as adding insulation to the walls. Calculations was carried out through derivatives that has been acknowledged for during the current study. The results that has been reported has been chosen regarding the general understanding of the study as well as the relevance it has on the final results in order to clearly answer the questions at issue. Keywords:   Energy efficiency, active heating, passive heating, transmission, total heat loss, building technics, diffusion, solar heat gain. / Tillgång till energi är i dagens samhälle en viktig del i vardagen. Energi nyttjas bland annat för att värma upp tappvarmvatten och bostäder samt för att förse byggnader med den energi som behövs för att dessa ska uppnå deras planerade funktioner. Krav på tillåten energianvändning finns för nybyggnationer och vid ändring av befintliga byggnader, dock gäller inte dessa krav för byggnader som väsentligt inte ska ändras. I och med detta har äldre byggnader i många fall en högre energianvändning än yngre byggnationer vilken kan minskas genom byggnadstekniska och installationstekniska åtgärder. Då byggnader energieffektiviseras sänks Sveriges totala energianvändning, kostnaderna för byggnadens aktiva uppvärmning minskar och den termiska komforten i en äldre byggnad kan förbättras. Genom beräkningar samt litteraturstudier är syftet med arbetet att i teorin energieffektivisera en äldre befintlig byggnad med hänsyn till ekonomi och avgränsad termisk komfort. Arbetet bygger på en empirisk studie vilken innefattar en fallstudie som har utförts på villan Lådberga 1:78 samt litteraturinsamling. Den datainsamling som har nyttjats för arbetet är fältmätningar, observationer samt dokumentanalyser. De energieffektiviseringsåtgärder som har undersökts i arbetet har valts ut med hjälp av arbetets litteraturstudie och för att undersöka hur olika energieffektiviseringsåtgärder påverkar den aktiva uppvärmningen i Lådberga 1:78 har beräkningar utförts. De beräkningar som har utförts uppvisar förändringar av byggnadens värmegenomgångskoefficienter vid respektive åtgärd samt en förändring av byggnadens aktiva uppvärmning. För att möjliggöra en jämförelse mellan byggnadens aktiva uppvärmning innan utförda åtgärder samt efter utförda åtgärder har även byggnadens energianvändning innan energieffektivisering beräknats. För att undersöka åtgärderna ur ett ekonomiskt perspektiv med hänsyn till återbetalningstid har Payback-metoden nyttjats. Vid åtgärder vilka innefattar tilläggsisolering har diffusionsberäkningar utförts. De åtgärder som har undersökts i arbetet är byggnadstekniska åtgärder i klimatskalet samt byte av värmesystem. Den åtgärd som har beräknats vara den mest lönsamma energieffektiviseringsåtgärden i byggnaden är byte av värmesystem. Åtgärden inkluderar byte från en pelletspanna till en bergvärmepump inklusive byte av fyra radiatorer. Denna åtgärd medför ett inbetalningsöverskott på cirka 18 100 kr/år och återbetalningstiden har beräknats till 10 år. Installationens livslängd har uppskattats vara mellan 20 till 40 år beroende på installationsdel. Den näst mest effektiva energieffektiviseringsåtgärden är tilläggsisolering av byggnadens vindsbjälklag. Denna åtgärd medför ett inbetalningsöverskott på cirka 2700 kr/år och har återbetalningstiden 14 år. Åtgärdens livslängd har uppskattats till minst byggnadens livslängd. Nackdelarna med åtgärderna är att båda leder till en minskad mängd värme till byggnadens kallvind vilket kan leda till fuktproblem, installation av en bergvärmepump påverkar även byggnadens självdragsventilation. De åtgärder som inte är lönsamma vid energieffektivisering av Lådberga 1:78 är byte av fönster, byte av dörrar samt tilläggsisolering av byggnadens träregelytterväggar då dessa åtgärder har återbetalningstider mellan 61 år till 92 år. Ytterligare en åtgärd som inte bör genomföras är tilläggsisolering av byggnadens betongytterväggar inifrån, detta på grund av att den relativa luftfuktigheten mellan isoleringen och betongen blir 100 %. De byggnadsdelar i byggnadens klimatskal vilka inte har undersökts via beräkningar är byggnadens krypgrund samt byggnadens betongplatta på mark. Byggnadens aktiva uppvärmning innan energieffektivisering är enligt beräkningar . För att förbättra den termiska komforten i byggnaden finns det möjlighet att utföra mindre förändringar av byggnadsdelarna i byggnadens klimatskal. Exempel på simpla åtgärder vilka kan utföras i Lådberga 1:78 är montering av tätningslister samt isolerglas på byggnadens fönster samt noggrann drevning runt av byggnadens fönster och dörrar. Nyckelord: Energieffektivisering, aktiv uppvärmning, passiv uppvärmning, transmission, total värmeförlust, diffusion, solenergitillförsel, tilläggsisolering.
27

Tilläggsisolering och fuktproblem i grundkonstruktionen platta på mark : En fallstudie i flerbostadshus inom stadsdelen Sätra i Gävle

Blom, Linus, Hedlund, Dan January 2014 (has links)
Between 1965 and 1974, the Swedish Parliament decided to build one million dwellings, called Million Program. The million program buildings were erected with new, untried design solutions, in a short range of time, and at low cost. The residential buildings from that time are now greatly in need of renovation. The municipal housing company, Gavlegårdarna, renovates and improves the energy efficiency at some of it’s apartment buildings in the district Sätra, Gävle. One problem is how to make the basic design of the slab on ground more energy efficiency and moisture proof. The study covers four representative flooring types in the Gavlegårdarnas million program area in Sätra. This study aims to investigate and evaluate proven methods for adding insulation in the four floor types. Also to look for solutions by designing additional insulation to treat damp problems and improve energy efficiency in an economical way. Existing flooring types are to be examined to check for new solutions as well. The aim is to produce a number of measures to provide property owners with different energy efficiency solutions. Results of calculations show that the perimeter area of the slab is exposed to moisture problems, while the centre of it does not have any notable problems. According to calculations, improved floor types have U-values reduced by 31% – 40% depending on the insulation thickness and design. However, investments have a long payback period and this is sometimes not economically viable. When a redevelopment project is performed, it is beneficial to simultaneously add insulation. If investors promote sustainable development, reduced energy consumption by the proposed measures is viable, as advocated by the environmental goals set by Sweden and the EU. / Sveriges riksdag beslutade att det skulle byggas en miljon bostäder, så kallade miljonprogramshus, mellan åren 1965 och 1974. Miljonprogramshusen uppfördes med nya och obeprövade konstruktionslösningar, på kort tid och till låga kostnader. Idag är bostadshusen från den tiden i stort behov av renovering. Det kommunalägda bostadsbolaget Gavlegårdarna håller på att renovera och energieffektivisera några av sina flerbostadshus i stadsdelen Sätra, Gävle. Ett problem är hur grundkonstruktionen, platta på mark i flerbostadshusen ska energieffektiviseras och fuktsäkras. Denna undersökning behandlar fyra representativa golvkonstruktioner som förekommer i Gavlegårdarnas miljonprogramsområde i Sätra. Syftet med undersökningen är att studera och utvärdera beprövade metoder för tilläggsisolering på de fyra utvalda golvtyperna. Lösningsförslagen på tilläggsisoleringsåtgärderna ska behandla fuktproblem, ekonomi och energieffektivisering. Resultaten från undersökningen visar att markplattans kantbalk är utsatt för fuktproblem medan plattans mitt inte har några anmärkningsvärda problem. Enligt U- värdesberäkningarna förbättras golvtypernas U-värde med 31 % - 40 % beroende på isoleringstjocklek och utförande, dock har investeringarna långa återbetalningstider. Utförs ett renoveringsarbete är det fördelaktigt att samtidigt tilläggsisolera. Satsar investerarna på en hållbar utveckling med minskad energianvändning rekommenderas förslagna åtgärderna, vilket förespråkas i miljömål uppsatta av Sverige och EU.
28

Ombyggnad av takkonstruktionen på Östermalms Saluhall : Utformning av tilläggsisolering med hänsyn till byggnadens kulturhistoriska värden / Reconstruction of the roof structure on Östermalms Saluhall : The formation of additional insulation considering the building's cultural historical values

Bergman, Anna, Ehrenberg, Edda January 2014 (has links)
Vid ombyggnad av Östermalms Saluhall är ett förslag att tilläggsisolera taket, då ställs det kulturhistoriska värdet av byggnaden mot ombyggnadskraven i BBR. Idag gäller samma krav vid nybyggnad som vid ombyggnad av en byggnad. Det kan därför uppstå tvister vid ombyggnaden av saluhallen, då det är svårt att samtidigt uppfylla nybyggnads- och ombyggnadskrav på de delar som ska ändras. De delar på saluhallen som studerats är två takdetaljer och de projekteras och analyseras byggtekniskt, kulturvärdesmässigt och lagmässigt. Det kulturhistoriska värdet hotas vid ombyggnation, men samtidigt vill Stockholms stad energieffektivisera byggnaden så gott det går. Studien handlar därför om hur man på bästa sätt ska kunna energieffektivisera byggnaden och följa de ombyggnationskrav som finns utan att förvanska byggnaden. / At the rebuilding of Östermalms Saluhall a proposal has been made to add insulation to the roof. The cultural historical values of the building is set against reconstruction requirements of the building regulations made by the National board of Housing, Building and Planning. Today, requirements for a new construction are the same as for an reconstruction of a building. Contradictions therefore arise in the rebuilding of the market hall because of the difficulty to achieve the construction requirements as well as the reconstruction requirements for the parts that are to be changed. The parts that are studied is two details of the roof and they are designed and analysed by technical building aspects, cultural historical values and by legal requirements. The cultural historical values are threatened by redevelopment, but at the same time Stockholm City wants to maximize the energy efficiency of the building. The study is therefore focusing on how to best maximize energy efficiency of the building and follow the redevelopment requirements that exist without corrupting the building.
29

Påverkan av en växtfasad på en befintlig byggnad i Halmstad

Olsson, Ronja, Wallmark, Lisa January 2024 (has links)
As the population increases, Swedish cities are becoming more urbanized. Consequently, people’s well-being deteriorates, and global warming has become reality. Buildings are replacing green spaces, necessitating the implementation of new methods to reintroduce greenery into urban areas. This study was conducted to investigate how a wall of an existing building in Halmstad, Sweden, is affected by supporting a living wall concerning load-bearing capacity, moisture, energy performance and economics. The methodology of this qualitative study includes literature review, interviews, and calculations for moisture, heat, and load-bearing capacity. The study found that living walls serve as additional insulation and that moisture does not affect the existing wall due to a vapor barrier. Also that the calculated wall withstands the weight of the living wall. Installation and maintenance costs can vary widely, and there is a wide range of plant species available. It's important to find plants that can withstand the climate for the specific wall. A broader selection of plants is available among those that wither in a beautiful way and are thus not evergreen. After interviews, it can be noted that living walls require minimal maintenance and thus maintenance costs are constant. Over time, some costs will be reduced as cooling and heating expenses decrease since the living wall acts as additional insulation.
30

Energieffektivisering av en tegelbyggnad i stadsmiljö

Håkansson, Thea, Nilsson, Lina January 2024 (has links)
Syftet med det här arbetet är att ge förslag på renoveringsåtgärder som kan förbättra energieffektiviteten i en kulturmärkt tegelbyggnad utan att riskera den befintliga konstruktionens karaktär. För att uppnå syftet undersöks en byggnad med ett stort kulturhistoriskt värde beläget i Halmstads stadskärna. I denna studie genomförs en energiinventering av byggnadens konstruktion och dess installationer. Energiinventeringen genomförs genom en intervju med en brukare av byggnaden, sammanställning av tidigare dokumentation om byggnaden och annan litteratur. Förslag på renoveringsåtgärder för byggnaden undersöks genom att studera slutsatser från tidigare forskning. Därefter undersöks det vilka åtgärder som kan tillämpas på byggnaden. För att fastställa hur renoveringsåtgärderna kan förbättra energieffektiviteten beräknas den nya genomsnittliga värmegenomgångskoefficienten och det nya primärenergitalet för byggnaden. Dessa beräkningar utförs med beprövade byggfysikaliska formler. I resultatet av studien framgår det att de valda renoveringsåtgärderna förbättrar byggnadens isolerande förmåga, vilket minskar behovet för uppvärmning. Detta sänker byggnadens primärenergital. Däremot uppnår inte det nya beräknade primärenergitalet det krav som ställs för nyproducerade byggnader. En möjlig anledning till att primärenergitalet inte uppnår kraven är att användningen av fastighetsel för byggnaden är mycket hög. Om de föreslagna renoveringsåtgärderna från detta arbete appliceras på en byggnad där fastighetselen är lägre hade möjligen ett lägre primärenergital uppnåtts. / This paper aims to suggest renovation measures to enhance energy efficiency in a historically significant brick building without altering its character. The case study focuses on a building with a high cultural value in the city center of Halmstad. An energy inventory is conducted through interviews, documentation of the building, and other relevant literature. Proposed renovation measures are examined by analyzing prior research and assessing how these solutions can be applied to the case study. The new average thermal transmittance and the new primary energy number are calculated using established building physics formulas to determine the potential energy efficiency improvements. Results show that the proposed renovation measures improve the building’s insulation, reducing the need for heating, which in turn lowers the primary energy number.  However, the new primary energy number does not meet the standards for new constructions, possibly due to high property electricity consumption in the reference building. If the proposed renovation measures were applied to a building with a lower property electricity consumption, a more significant reduction in the primary energy number might be achieved.

Page generated in 0.1018 seconds