• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 352
  • 111
  • 22
  • 16
  • 6
  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 583
  • 583
  • 253
  • 250
  • 102
  • 69
  • 62
  • 55
  • 51
  • 48
  • 46
  • 44
  • 42
  • 40
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
531

\"Terapia endodôntica associada à irradiação do canal radicular com laser de diodo: avaliação térmica, morfológica, microbiológica e da infiltração marginal apical\" / Endodontic root canal therapy usindg diode laser irradiation: thermographic, morphological, microbiological and marginal apical leakge studies

Adriana da Costa Ribeiro 06 February 2007 (has links)
O objetivo deste estudo foi avaliar os efeitos da irradiação do canal radicular pelo laser de diodo, quando associado à terapêutica endodôntica tradicional: no aumento da temperatura na superfície radicular externa; nas alterações morfológicas da dentina do canal radicular; no selamento marginal apical após obturação do canal radicular e no potencial de redução microbiana. O aumento de temperatura foi monitorado durante a irradiação do canal radicular de incisivos inferiores por câmera termográfica. Os parâmetros de irradiação foram: grupo de emissão contínua (CW): P=2,5 W e grupo de emissão pulsada ?P=1,25 W. A avaliação das alterações morfológicas por MEV das amostras irradiadas nas condições acima citadas foram comparadas com amostras não irradiadas. O grau de infiltração marginal apical foi mensurado em amostras irradiadas (CW; P = 2,5 W) ou não irradiadas, e obturadas por um dos três cimentos endodônticos: N-Rickert, AH Plus ou Apexit. O grau de penetração linear foi medido após o período de imersão das amostras na solução de azul de metileno. O potencial de redução microbiana promovido pela associação do laser à terapêutica endodôntica tradicional foi avaliado em dentes portadores de infecção endodôntica primária por técnicas de cultura e PCR. A irrigação de NaOCl 0,5 % e uso de hidróxido de cálcio (grupo controle) foram associados à irradiação no grupo laser (CW; P=2,5 W). Foram avaliadas: a redução do número de UFC dos anaeróbios viáveis, a quantidade de E. faecalis e de lactobacilos/amostra, e a proporção de E. faecalis e de lactobacilos/microrganismos viáveis. O aumento de temperatura na superfície radicular externa durante a irradiação do canal radicular nos regimes de emissão contínuo e pulsado não excedeu o limite crítico de 10 ºC. A variação de 10 temperatura mediana máxima na região apical usando o método de Wilcoxon (p < 0,05) foi de 8,6 °C na irradiação contínua e de 3,3 °C na emissão pulsada. O tempo de resfriamento de 20 segundos foi determinado entre os 5 ciclos de irradiação. As alterações morfológicas promovidas pela irradiação do canal revelaram fusão da dentina e obliteração dos túbulos dentinários especialmente no terço apical, em ambas as condições de irradiação. A irradiação do canal radicular pelo laser de diodo reduziu significativamente o grau de infiltração marginal apical nos canais obturados pelo cimento Apexit (Kruskal Wallis p < 0,05). A prevalência dos anaeróbios viáveis ao final do tratamento foi menor no grupo laser do que no grupo controle, embora não tivesse sido constatada diferença significante entre os grupos (Mann-Whitney p > 0,05). O porcentual de lactobacilos/microrganismos viáveis no início do tratamento foi 22 % reduzindo a zero ao final, no grupo controle. Esse microrganismo não foi detectado no grupo laser. A proporção de Enterococcus/microrganismos viáveis variou de 36 %-50 % no grupo controle, e 22 %-0 % no grupo laser, no início e final do tratamento, respectivamente. Nas condições testadas, os resultados sugerem que o laser de diodo mostrouse uma ferramenta possível de ser incorporada à Endodontia, contudo os efeitos biológicos são similares à terapêutica endodôntica tradicional bem executada. / The aim of this study was to evaluate the effects of diode laser irradiation associated with endodontic therapy. The aspects analyzed were: temperature rise at the external root surface, morphological changes at the dentine root walls, apical marginal leakage after root sealing, and microbiological reduction after laser irradiation. The temperature rise in inferior incisor teeth was monitored using a thermographic camera. Two laser treatment parameters were investigated: continuous emission mode (CW) with P = 2.5 W and pulsed emission mode (PL) with average power?P = 1.25 W. The morphological changes of irradiated samples were analyzed by SEM for both treatment modes and compared with a non-irradiated control group. The apical marginal leakage was measured after the immersion in methylene blue solution for irradiated (CW; P = 2.5 W) and non-irradiated samples sealed by one of the following endodontic sealers: N-Rickert, AH Plus or Apexit. The reduction in microbiological activity after conventional endodontic therapy and after laser irradiation was evaluated in primary endodontic infection using culture and PCR techniques, where the control group used conventional 0.5 % NaOCl solution and calcium hydroxide treatment was compared with laser irradiation (CW; P = 2.5 W). The reduction of viable anaerobic microorganisms, the quantity of E. faecalis and Lactobacillus per samples, and the rate of E. faecalis and Lactobacillus per viable microorganism were analyzed. The temperature rise at external root surface during root canal irradiation in both continuous and pulsed emission modes was demonstrated not exceed the safety limit of 10 ºC. The maximum median temperature variation was 8.6 °C (CW) at the continuous emission mode and 1.6 °C at pulsed mode (PL) (Wilcoxon, p < 0.05). The optimal ?resting time? between each of five irradiation cycles was 12 determined to be 20 seconds to allow for tissue cooling and hence to prevent potential dangerous rises in the tissue temperature. SEM analysis revealed melting of dentine and closure of dentinal tubules especially at apical third for both irradiation conditions. The apical marginal leakage was significant reduced in the irradiated samples sealed with Apexit (Kruskal Wallis, p < 0.05). The prevalence of the viable anaerobic microorganisms exhibited reduced with time in both the control and laser groups with no statistical difference (Mann-Whitney p > 0.05). The Lactobacillus rate per viable microorganisms in the control group was 22 % at the beginning of the treatment and decreasing to zero at the end. This microorganism was not detected in laser group. The rate of Enterococcus per viable microorganism ranged 36 % to 50 % in the control group and 22 % to 0 % in laser group at the begin and the end of treatments, respectively. The conclusion is that diode laser technology is suitable for applications in endodontic therapy under the conditions tested in this study, however, the biological effects are similar to well done conventional endodontic therapy.
532

Ensaio clínico quali-quantitativo para avaliar a eficácia e a efetividade do tratamento homeopático individualizado na rinite alérgica perene / Quali-quantitative clinical trial to evaluate the efficacy and the effectiveness of individualized homeopathic treatment in perennial allergic rhinitis

Marcus Zulian Teixeira 06 February 2009 (has links)
INTRODUÇÃO: A rinite alérgica é uma condição clínica comum que apresenta sintomas diversos num significante número de pacientes, deteriorando a qualidade de vida daqueles refratários aos tratamentos usuais (anti-histamínicos e corticosteróides nasais tópicos). Apresentando princípios curativos similares, a imunoterapia sublingual e a homeopatia podem reduzir os sintomas e a necessidade de medicamentos na rinite alérgica, embora a eficácia e a efetividade de ambas terapêuticas não sejam ainda suficientemente conhecidas. OBJETIVOS: O objetivo deste estudo foi avaliar a efetividade clínica do tratamento homeopático individualizado prolongado, comparativamente ao placebo, em adultos portadores de rinite alérgica perene. MÉTODOS: Um total de 41 pacientes com rinite alérgica perene foi alocado numa primeira fase duplo-cego e placebo-controlada durante seis meses, sendo tratada com doses sublinguais semanais de medicamentos homeopáticos individualizados ou placebo. Após esta fase inicial fechada, todos os pacientes foram convidados a participar de uma segunda fase controlada aberta, em que receberiam tratamento homeopático pelo período máximo de 36 meses, e os resultados foram comparados com a melhora da fase inicial. O escore dos sinais e sintomas, a necessidade de medicamentos de resgate e a qualidade de vida foram mensurados por questionários e avaliações clínicas pessoais, aplicadas por um mesmo avaliador independente, antes e após cada fase. As doses dos medicamentos homeopáticos e de resgate utilizados, assim como os efeitos colaterais, foram documentados num diário pessoal. Os desfechos clínicos primário e secundários foram, respectivamente, os escores dos sinais e sintomas alérgicos específicos e gerais. Títulos da IgE total foram mensurados antes e após cada fase. RESULTADOS: Após os seis meses da fase placebo-controlada inicial, na análise por protocolo de todos os pacientes incluídos no estudo, não foram observadas diferenças significativas entre os grupos ativo e placebo nos escores clínicos, na utilização de drogas de resgate, na qualidade de vida e nos títulos da IgE total. Entretanto, as análises dos subgrupos da segunda fase mostraram uma crescente e significativa melhora nos desfechos clínicos primário e secundários após 12 meses de tratamento homeopático individualizado, comparativamente à variação de melhora dos mesmos pacientes na fase inicial fechada. Diferença significativa na qualidade de vida foi observada apenas após o segundo ano de tratamento homeopático. CONCLUSÃO: Neste estudo, o tratamento homeopático foi acompanhado de um significante efeito placebo. A efetividade da homeopatia pôde ser observada após 12 meses da terapêutica, apresentando efeito preventivo de longa duração após 36 meses de tratamento homeopático individualizado. / INTRODUCTION: Allergic rhinitis is a common clinical condition which presented several symptoms in a significant number of patients, deteriorating the quality of life in those resistant to the usual treatments (antihistamines and topical nasal corticosteroids). Presenting similar curative principles, sublingual immunotherapy and homeopathy can reduce symptoms and medication requirements in allergic rhinitis, although the efficacy and effectiveness of both therapeutics are not still sufficiently known. OBJECTIVES: The objective of this study was to evaluate clinical effectiveness of prolonged individualized homeopathic treatment, compared with placebo, in adults with perennial allergic rhinitis. METHODS: A total of 41 adults with perennial allergic rhinitis were enrolled in a first double-blind placebo-controlled phase for six months, and treated on a weekly basis with sublingual doses of single individualized homeopathic medicines or placebo. After this closed initial phase, all patients were invited to participate in an open label controlled phase, in that they would receive homeopathic treatment for the maximum period of 36 months, and the results were compared with the improvement of the initial phase. Signs and symptoms scores, rescue medication requirements and quality of life were assessed by questionnaires and personal clinical evaluation by a same independent researcher, before and after each phase. Applied homeopathic and rescue drugs dosage, and side effects were documented by diary cards. Primary and secondary clinical outcome were, respectively, specific and general allergic signs and symptoms scores. Total IgE titles were performed before and after each phase. RESULTS: After six months of placebo-controlled phase, analyzing all patients included in the study per protocol, we observed no significant difference between treatment and placebo groups in primary and secondary clinical outcomes, use of rescue drugs, quality of life and total IgE. However, second phase subgroups analysis showed a significant and growing improvement of clinical symptoms after 12 months of individualized homeopathic treatment, comparatively to the same patients\' variation in closed initial phase. Significant difference in quality of life score were observed only after second homeopathic treatment year. CONCLUSION: In this study, homeopathic treatment was accompanied by a significant placebo effect. Effectiveness of homeopathy could be seen after 12 months of therapy, presenting preventive effect of long duration after 36 months of individualized homeopathic treatment.
533

Uma revisão sistemática e metanálise sobre os eventos adversos decorrentes do uso de benzodiazepínicos pos idosos. / A systematic review and meta-analysis about the adverse events resulting from the use of benzodiazepines by elderly.

Ricardo Portugal Basile 12 November 2014 (has links)
O avanço econômico, científico e tecnológico, vem levando a um aumento da expectativa de vida e consequente envelhecimento da população. Assim, o idoso requer atenção especial pela maior incidência de doenças crônicas e degenerativas e pelo aumento concomitante no uso de fármacos, podendo ocasionar complicações pela sua maior vulnerabilidade à eventos adversos (EAs), uso inapropriado e abusivo, exposição à interações medicamentosas sérias, e casos de iatrogenias. Acrescenta-se o fato particular de um aumento abusivo no uso de benzodiazepínicos (BDZs). O objetivo deste trabalho foi rever e sintetizar as evidências geradas por ensaios clínicos controlados e randomizados sobre a incidência de EAs relacionados ao uso de BDZs em idosos com ansiedade ou insônia em comparação àqueles que, sob as mesmas condições clínicas, não o utilizaram. Desenvolveu-se a recuperação de artigos em cinco bases de dados eletrônicas na área da saúde (PubMed, SCOPUS, Web of Science, Cochrane Central, e LILACS), para posterior análise combinada (metanálise) dos resultados evidenciados. / The economic, scientific and technological progresses have provided an increase in life expectancy and the consequent process of aging. Thus, the elderly requires special attention due to the higher incidence of chronic and degenerative diseases and the higher concomitant increase in the drugs use that may cause complications by increasing ulnerability for adverse events (AEs); nappropriate and abusive use; exposition to serious drug interactions, and iatrogenic cases. Add to these the particular abusive increase in benzodiazepine (BDZ) use. The objective of this study was to review and synthesize the evidence generated by randomized controlled trials on the incidence of AEs related to therapy with BDZs in elderly with anxiety or insomnia compared to those under the same clinical conditions, not medicated. The articles were recovered in five healthcare electronic databases (PubMed, SCOPUS, Web of Science, Cochrane Central, and LILACS), for subsequent combined analysis (meta-analysis) of the results.
534

Aspectos clínicos e bioquímicos da Doença de Machado-Joseph : da descrição de novos biomarcadores à busca de um tratamento efetivo

Saute, Jonas Alex Morales January 2013 (has links)
Introdução: A doença de Machado-Joseph (DMJ) ou ataxia espinocerebelar tipo 3 (SCA3) é causada por uma expansão de trinucleotídeos CAG no gene ATXN3, que leva à degeneração de múltiplos sistemas neurológicos. Seu curso é invariavelmente progressivo, não havendo tratamento específico. Objetivos: Descrever novos biomarcadores, aspectos não motores e definir quais escalas clínicas devem ser utilizadas como desfechos principais nos futuros ensaios clínicos randomizados (ECR) para a DMJ/SCA3. Além de avaliar se o tratamento com carbonato de lítio é seguro e efetivo em reduzir a progressão desta condição. Métodos: Em estudo caso-controle avaliamos: 1) a relação dos sintomas depressivos na DMJ/SCA3, pelo inventário de Beck (BDI), com aspectos de gravidade clínica e molecular; 2) alterações no índice de massa corporal (IMC) e sua correlação com aspectos clínico-moleculares e de neuroimagem; e 3) o Sistema Insulina/ IGF-1 (IIS) e o potencial de seus componentes como biomarcadores. Fizemos uma revisão sistemática sobre os aspectos psicométricos das escalas clínicas de SCAs já descritas, para em seguida iniciarmos um ECR, duplo-cego, paralelo, placebo-controlado de fase 2/3. Para este estudo foram randomizados 62 pacientes com diagnóstico molecular prévio de DMJ/SCA3 com marcha independente e ≤ 10 anos de doença (1:1) para tratamento com carbonato de lítio (0.5-0.8mEq/L) ou placebo. Resultados: Os escores do BDI foram mais elevados na DMJ/SCA3 (p= 0.012) e correlacionaram-se significativamente apenas com as escalas SARA (R=0.359, p=0.01) e NESSCA (R=0.412, p=0.003). Os pacientes com DMJ/SCA3 (N=46) apresentaram IMC menor (24.4 ± 4.1) do que os indivíduos controle (N=42, 27.1± 4.5, p=0.01), havendo correlação inversa (R=−0.396, p=0.015) entre o IMC e o tamanho da sequencia repetitiva CAG (CAGn). Encontramos uma maior sensibilidade periférica à insulina (HOMA2-%S, p=0.003, corrigido pelo IMC) e níveis séricos mais elevados da proteína ligante do IGF-1, IGFBP-1 (p=0.001) na DMJ/SCA3. A IGFBP1 correlacionou-se diretamente à CAGn (R=0.452; p = 0.006) e a sensibilidade à insulina inversamente à idade de início dos sintomas (R=-0.444; P = 0.003). Concluímos, na revisão sistemática, que as escalas semi-quantitativas SARA e NESSCA, e as quantitativas SCAFI e CCFS seriam os melhores desfechos para um ECR. O uso de lítio foi seguro após 24 semanas de tratamento, não havendo diferenças no número total de eventos adversos entre os grupos lítio (50,3%) e placebo (49,7%, p=1.00). O grupo placebo apresentou maior progressão (que não foi significativa) nos escores NESSCA (0.35 pontos, 95% IC -1.0 a 1.7, p=0.222, desfecho primário de efetividade) e SARA (0.96 pontos, 95% IC -0.46 a 2.38, p=0.329), após 48 semanas de tratamento. A gravidade da ataxia de marcha (p=0.008), as provas funcionais quantitativas: PATA rate (p=0.002) e Click Test ND (p=0.023), e os escores compostos SCAFI (p=0.015) e CCFS (p=0.029) apresentaram menor progressão no grupo tratado com lítio durante as 48 semanas. Conclusão: Os resultados destes estudos ajudam no entendimento da depressão e alterações nutricionais da DMJ/SCA3 e apontam a IGFBP-1 como biomarcador e a sensibilidade periférica insulínica como modificador do fenótipo. Houve efetividade do tratamento com carbonato de lítio nos desfechos secundários do ECR, sendo necessária confirmação por ensaios clínicos multicêntricos. / Background: Machado-Joseph disease (MJD) or spinocerebellar ataxia type 3 (SCA3) is caused by a CAG repeat expansion at ATXN3 gene, leading to progressive degeneration of multiple neurological systems. MJD/SCA3 is an invariably progressive disorder, with no current treatment. Objectives: To describe new disease biomarkers, non-motor aspects and to define the clinical SCA scales to be utilized as main outcomes in future randomized controlled trials (RCT) on MJD/SCA3. And further assess safety and effectiveness of lithium carbonate in reducing the progression of this condition. Methods: We performed a case-control study to evaluate: 1) the relation of MJD/SCA3 depressive symptoms, through Beck depression Inventory (BDI), with other clinical and molecular findings; 2) the Body Mass Index (BMI) of MJD/SCA3 patients and the correlation with other clinical, molecular and neuroimaging findings; and 3) the Insulin/IGF-1 system (IIS) in MJD/SCA3 and the possible biomarker properties of its components. We further performed a systematic review on the psychometric properties of the described SCAs scales in order to initiate the double-blind, parallel, placebo-controlled phase 2/3 clinical trial. 62 independently ambulatory MJD/SCA3 patients with ≤ 10 years of disease duration were randomly assigned in the RCT (1:1) to lithium (0.5-0.8mEq/L) or placebo. Results: BDI scores were higher in MJD/SCA3 patients (p= 0.012), with significant correlations only with the scales SARA (R=0.359, p=0.01) and NESSCA (R=0.412, p=0.003). MJD/SCA3 patients (N=46) presented lower BMI (24.4 ± 4.1) than control individuals (N=42, 27.1± 4.5, p=0.01). BMI correlated inversely with the length of the expanded CAG repeat (CAGn). We found higher peripheral sensitivity to insulin (HOMA2-%S, p=0.003, corrected for BMI) and serum levels of the IGF-1 binding protein, IGFBP-1 (p=0.001) in MJD/SCA3. IGFBP-1 correlated with CAGn (R=0.452; p = 0.006) and insulin sensitivity with the age of disease onset (R=-0.444; P = 0.003). In the systematic review we concluded that the semiquantitative SCA scales SARA and NESSCA and the quantitative instruments SCAFI and CCFS would be the most appropriate outcomes for the RCT. After 24 weeks, there were no differences in the number of adverse events in lithium (50.3%) and placebo (40.7%) groups (p=1.00) in the RCT. The placebo group presented a non-significant faster progression on NESSCA (0.35 points, 95% CI -1.0 to 1.7, p=0.612, primary effectiveness outcome) and SARA (0.96 points, 95% CI -0.46 to 2.38, p=0.186), after 48 weeks of treatment. Gait ataxia severity (p=0.008), the quantitative performance tasks: PATA rate (p=0.002) and Click Test ND (p=0.023), and the composite scores SCAFI (p=0.015) and CCFS (p=0.029) presented a slower progression under lithium therapy in the overall 48 weeks period. Conclusion: These studies added to the understanding of depressive and nutritional manifestations of MJD/SCA3 and points IGFBP-1 as a biomarker and peripheral insulin sensitivity as a disease phenotype modifier. The effectiveness of lithium carbonate treatment shown in secondary outcomes of the RCT opened a perspective for an effective therapy for this untreatable disorder that must be confirmed by large multicentric clinical trials.
535

Balão de contrapulsação intra-aórtico eletivo em pacientes de alto risco submetidos a cirurgia cardíaca: estudo prospectivo e randomizado / Elective intra-aortic balloon counterpulsation in high-risk patients undergoing cardiac surgery: a prospective and randomized study

Graziela dos Santos Rocha Ferreira 13 December 2016 (has links)
Introdução: O balão de contrapulsação intra-aórtico (BIA) é usado em uma variedade de contextos relacionados à disfunção miocárdica. Na cirurgia cardíaca, seu papel em desfechos clínicos é motivo de debate devido a resultados conflitantes de análises retrospectivas e limitações de recentes estudos prospectivos. Objetivo: O objetivo do presente estudo foi avaliar a eficácia e segurança do BIA eletivo na ocorrência de um desfecho composto de complicações clínicas incluindo mortalidade em pacientes de alto risco submetidos a cirurgia cardíaca de revascularização miocárdica (RM). Métodos: Estudo clínico prospectivo e randomizado realizado no Instituto do Coração (InCor) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo. Foram incluídos 181 pacientes adultos submetidos a cirurgia cardíaca de RM no período de abril de 2014 a junho de 2016, com um ou mais dos seguintes critérios: fração de ejeção menor ou igual a 40% e/ou EuroScore maior ou igual a 6. Os pacientes foram randomizados para uso do BIA logo após a indução anestésica ou para grupo controle. Após 24 horas do procedimento, o suporte com o balão intra-aórtico era suspenso se o paciente apresentasse índice cardíaco maior ou igual a 2,2 L/min/m2 com suporte inotrópico mínimo (dobutamina menor ou igual a 5 mcg/Kg/min) ou se o paciente apresentasse efeito colateral grave relacionado ao balão. O desfecho primário foi um composto de mortalidade e complicações graves em 30 dias após a cirurgia (choque cardiogênico, necessidade de reoperação, acidente vascular cerebral, insuficiência renal aguda, infecção de ferida esternal profunda e tempo de ventilação mecânica prolongada). Resultados: Dos pacientes incluídos no estudo, 90 foram alocados para a estratégia de uso do balão intra-aórtico eletivo e 91 para a estratégia controle. O desfecho primário foi observado em 47,8% do grupo BIA e em 46,2% do grupo controle (P=0,456). Não houve diferenças significativas entre os grupos BIA e controle respectivamente, em relação à ocorrência de óbito em 30 dias (14,4% vs 12,1%, P=0,600), choque cardiogênico (18,0% vs 18,9%, P=0,982), reoperação (3,4% vs 4,4%, P=1,000), tempo de ventilação mecânica prolongado (5,6% vs 7,7%, P=0,696), insuficiência renal aguda (22,2% vs 14,3%, P=0,123), acidente vascular cerebral (2,2% vs 2,2%, P=0,123) ou infecção de ferida operatória profunda (7,8% vs 14,3%, P=0,249). O tempo de uso de inotrópico foi significativamente maior no grupo BIA em comparação ao grupo controle (51 horas [32-94] vs 39 horas [25-66], P=0,007). O tempo de internação em UTI foi mais prolongado no grupo BIA comparado ao grupo controle (5 dias [3-8] vs 4 dias [3-6], P=0,035). O tempo de internação hospitalar foi semelhante entre os grupos (13 dias [9-18] vs 11 dias [8-17], P=0,302). Não houve diferença em relação a incidência de complicações relacionadas ao uso do BIA entre os dois grupos. Conclusão: A estratégia de uso do balão intra-aórtico eletivo em pacientes de alto risco submetidos a cirurgia de revascularização miocárdica não reduziu o desfecho combinado de óbito e/ou complicações graves em 30 dias / Introduction: The intra-aortic balloon pump (IABP) is used in a variety of clinical settings in which myocardial function is reduced. In cardiac surgery, its role on clinical outcomes is debated due to conflicting results of retrospective analysis and limitations of recent prospective studies. Objective: The purpose of this study was to evaluate the efficacy and safety of elective IABP use on outcomes in high-risk patients undergoing cardiac surgery. Methods: A prospective randomized controlled trial that evaluated 181 patients undergoing coronary artery bypass at the Heart Institute/University of Sao Paolo from 2014 April to 2016 June. Inclusion criteria were left ventricular ejection fraction (LVEF) <= 40% and/or EuroSCORE>= 6. Eligible patients were randomly assigned, in a 1:1 ratio, to IABP group (n=90) or control group (n=91). Removal of IABP catheter was accomplished after 24 hours of the procedure under the following circumstances: cardiac index >= 2.2 L/min/m2 and dobutamine infusion dose <= 5 ?g/kg/min. The catheter was immediately removed if a severe adverse event related to the procedure was detected. The primary outcome was the composite endpoint of mortality and major morbidity in 30 days after cardiac surgery (cardiogenic shock, need for reoperation, stroke, acute renal failure, mediastinitis and prolonged mechanical ventilation ( > 24 hours). Results: The primary outcome was observed in 47,8% in the IABP group and 46,2% in the control group (P=0,456). There were no differences in the primary outcome: 30-day mortality (14,4% vs 12,1%, P=0,600), cardiogenic shock (18,0% vs 18,9%, P=0,982), need for reoperation (3,4% vs 4,4%, P=1,000), prolonged mechanical ventilation (5,6% vs 7,7%, P=0,696), acute renal failure (22,2% vs 14,3%, P=0,123), stroke (2,2% vs 2,2%, P=0,123) or mediastinitis (7,8% vs 14,3%, P=0,249). Patients from the IABP group had a greater duration of inotrope use (51 hours [32-94] vs 39 hours [25-66], P=0,007) and longer intensive care unit length of stay (five days [3-8] vs four days [3-6], P=0,035). The length of hospital stay was similar (13 days [9-18] vs 11 days [8-17], P=0,302). There were no differences on the incidence of complications related to the IABP use in both groups. Conclusions: The elective IABP use did not reduce 30-day major complications in high-risk patients undergoing cardiac surgery
536

Efeito do laser e ultrassom na dor e incapacidade funcional de mulheres com lombalgia crônica não específica: ensaio clínico randomizado / Effect of laser, continuous and pulsed ultrasound on pain, functional disability of women with non-specific low back pain: a randomized controled trial

Ana Paula Fernandes De Angelis Rubira 20 August 2015 (has links)
Introdução: A lombalgia é frequentemente acompanhada por exacerbação da dore incapacidade funcional. Entre os recursos usados no tratamento estão o laser, ultrassom contínuo e pulsátil,porém os efeitos são controversos. Objetivos:Verificar o efeito do laser e do ultrassom contínuo e pulsátil na dor e na incapacidade funcional de mulheres com lombalgia crônica não específica.Casuística e Método: A amostra foi composta por 100 voluntárias alocadas aleatoriamente em quatro grupos: Laser (n=26) tratadas com 3J; Ultrassom Pulsátil(n=24)de 3 MHz, tratadas com 1W/cm²; Ultrassom Contínuo (n=26) de 1 MHz, tratadas com 1W/cm²; e Controle (n=24), que aguardou tratamento.A intensidade da dor foi avaliada com a Escala Visual analógica (EVA), a qualidade da dor com o questionário de dor McGille a incapacidade funcional com o questionário de Roland Morris, antes e após 10 sessões de tratamento.Resultados:Os três grupos tratados tiveram diminuição na dor(p < 0,001), mas o grupo Laser apresentou ganho relativo de 91,2%; Ultrassom Pulsátil 76,8%; grupo Ultrassom Contínuo 81,5% e o grupo Controle piora de -5,8%. Os três grupos tratados tiveram melhora na qualidade da dor (McGill) total, sensorial e afetiva (p < 0,005; p < 0,002; p < 0,013, respectivamente).Todos os grupos tratados apresentaram diminuição na incapacidade funcional (p < 0,001),porém o grupo Ultrassom Pulsátil obteve o maior ganho relativo de 83,3% em comparação com os grupos Laser (62,5%), Ultrassom Contínuo (50%) e Controle(-37,5%). Conclusão: O laser pulsátil de baixa intensidade, ultrassom terapêutico 3 MHz e 1 MHz nos modos pulsátil e contínuo, respectivamente, tem efeitos significativos na diminuição da dor lombar e na melhora da incapacidade funcional em portadoras de lombalgia crônica não específica. Quanto ao ganho relativo, o laser pulsátil de baixa intensidade teve melhor efeito na dor enquanto o ultrassom 3 MHz, modo pulsátil, na melhora da incapacidade funcional / Introduction: low back pain is often accompanied by exacerbation of pain and functional disability. Laser, Continuous and Pulsatile Ultrasound are used for the treatment, but its effects are controversial. Objectives: To assess the effect of the laser, the pulsatile and the continuous ultrasound on pain and functional disability in women with chronic non-specific low back pain. Material and methods: The sample was composed of 100 volunteers randomly allocated into four groups: Laser (n= 26) treated with 3 J; Pulsed Ultrasound (n= 24) of 3 MHz, treated with 1W/cm2; Continuous Ultrasound (n= 26) of 1 MHz, treated with 1W/cm2); and a Control Group (n= 24), who waited for treatment. The intensity of pain was assessed using the Visual Analogue Scale (VAS), the quality of pain with the of the McGill pain questionnaire and the functional disability with the Roland-Morris questionnaire, before and after 10 session of treatment.Results: The three treated groups had decrease in pain (p < 0.001), but the Laser group showed relative gain of 91.2 %; pulsed Ultrasound 76.8 %; group Continuous Ultrasound 81.5% and the Control group worsening of -5.8 %. The three treated groups had improvement in the quality of pain (McGill), total, sensory and affective dimension (p < 0.005; p < 0.002; p < 0.013, respectively). All treated groups showed a decrease in functional disability (p < 0.001), but the Pulsatile Ultrasound group showed the highest relative gain (83.3%) in comparison with the Laser (62.5 % ), Continuous Ultrasound (50 %) and Control groups (-37.5 % ). Conclusion:The pulsed laser, pulsed and continuous ultrassom have significant effects in decrease of low back pain and improve the functional disability in women with non-specific chronic low back pain, but the pulsed low level laser had the best results on pain while the pulsed ultrasound had the best results on improve the functional disability
537

Eficácia da ondansetrona no tratamento de dependentes de álcool / Efficacy of ondansetron for the treatment of alcohol dependent outpatients

João Maria Corrêa Filho 10 July 2013 (has links)
INTRODUÇÃO: A dependência de álcool é um grave problema de saúde publica no Brasil. Seu tratamento ainda é um desafio, mesmo para os melhores programas terapêuticos disponíveis. Esta dificuldade ocorre pelo pequeno número de medicamentos aprovados para o uso e também pela elevada taxa de abandono, próximo a 50%. A ondansetrona tem surgido como uma medicação promissora para o tratamento de alcoolistas. A identificação de pacientes com maior risco de desistência do tratamento é uma estratégia para reverter essa taxa. Os objetivos deste estudo são: (a) avaliar a eficácia e segurança da ondansetrona na dose de 16 mg/dia; (b) investigar variáveis clínicas e psicossociais capazes de prever maior aderência ao tratamento; (c) desenvolver uma tipologia para alcoolistas com características presentes no início do tratamento; (d) testar se os diferentes tipos podem prever o abandono ao tratamento. METODOS: Trata-se de estudo realizado em três etapas. Na primeira foi realizado ensaio clinico randomizado duplo-cego placebo controlado, com ondansetrona, por 12 semanas, desenvolvido na Universidade de São Paulo - Brasil. A amostra era composta por 102 dependentes de álcool com idade entre 18 - 60 anos. A análise foi realizada com os dados brutos e com os dados imputados. Na segunda etapa, foi combinado o banco de dados deste estudo com os de outros dois ensaios realizados no mesmo local (acamprosato versus placebo e naltrexona, topiramato versus placebo), com número total de 332 dependentes de álcool. A partir da análise de quatro fatores clínicos (idade de início dos problemas com uso do álcool, alcoolismo familiar, gravidade da dependência do álcool e intensidade de sintomas depressivos) foi realizada a análise de cluster tipo K-Means e, após a identificação dos tipos, foi avaliada a associação destes com a adesão ao tratamento. Na última etapa, analisando apenas os participantes avaliados quanto ao desejo pelo álcool (257 alcoolistas) foi realizada uma regressão logística, com variáveis clínicas e psicossociais, para analisar a influência dessas na retenção ao tratamento. RESULTADO: A ondansetrona foi capaz de retardar o tempo para o primeiro consumo de álcool (54,7 versus 40,9 dias) e, também, o primeiro consumo pesado de álcool (58,4 versus 45,4 dias) quando comparado ao placebo. Essa droga não influenciou a percentagem de dias bebidos durante o estudo, mas esteve associada com menor percentagem de dias com consumo pesado de álcool (7,8% versus 11,7%), quando comparado ao placebo, na análise de dados imputados. Na análise de tipologia foram identificados dois grupos de alcoolistas. O tipo de alcoolista caracterizado pelo início precoce dos problemas com álcool, maior histórico familiar de dependência, elevada gravidade de alcoolismo e poucos sintomas depressivos esteve associado a maior chance de descontinuar o tratamento, independente da medicação usada e da participação nos alcoólicos anônimos (AA). Entre as variáveis clínicas e psicossociais estudadas, ter idade mais elevada, participar do AA e o consumo preferencial pela cerveja foram fatores independentes associados a maior adesão ao tratamento. Maiores escores de depressão aumentaram o risco de abandono. CONCLUSÃO: A ondansetrona mostrou ser segura e bem tolerada na dose de 16mg/dia. Foi mais eficaz que o placebo em retardar o primeiro consumo e primeiro consumo pesado de álcool, deixou dúvida sobre seu efeito na percentagem de dias bebidos e de consumo pesado de álcool. O tipo de alcoolista com idade precoce de problemas com álcool, elevada dependência dessa substância, mais história familiar de alcoolismo e menos sintomas depressivos, esteve associado ao maior risco de abandono. Idade mais elevada, frequentar o AA e ter preferência pela cerveja aumenta a chance de completar o tratamento proposto / INTRODUCTION: Alcohol dependence is a serious public health problem in Brazil. Its treatment remains a challenge, even for the best available treatment programs. This difficulty is due to the small number of drugs approved for use and also the high dropout rates, close to 50%. Ondansetron has emerged as a promising drug for the treatment of alcoholics. The identification of patients with increased risk of treatment discontinuation is a strategy to reverse these rates. The aims of this study are: (a) to evaluate the efficacy and safety of ondansetron in a dose of 16 mg/day; (b) to investigate clinical and psychosocial variables that could predict treatment retention, (c) to develop a typology of alcoholics based on clinical factors present at the beginning of the treatment; and (d) to test if different types of alcoholics could predict the higher withdrawal from treatment. METHODS: This study was conducted in three stages. Firstly, a randomized, double-blind, placebo- controlled clinical trial was conducted with ondansetron for 12 weeks, developed at the University of São Paulo - Brazil. The sample consisted of 102 alcoholics aged between 18 and 60 years old. The analysis was performed by using only the sample of adherents and an imputed sample. Secondly, the database of this study was combined with two other clinical trials that were carried out in the same setting (acamprosate versus placebo, and topiramate, naltrexone versus placebo), with a final sample size of 332 alcohol dependents. From the analysis of four clinical factors (problem drinking onset age, family alcoholism, severity of alcohol dependence and intensity of depressive symptoms) a K-means cluster analysis was performed to identify types of alcoholics. In addition, the association between the resulting types of alcoholics and treatment retention was verified. Thirdly, using only the participants who were evaluated for craving on alcohol (257 alcoholics), a logistic regression analysis was run with clinical and psychosocial variables as independent variables to analyze their influence on treatment retention. RESULTS: Ondansetron was able to delay the first alcohol consumption (54.7 versus 40.9 days) and the first heavy alcohol consumption (58.4 versus 45.4 days) compared to placebo. Ondansetron did not have effect on the percentage of drinking days. However, ondansetron was associated with a lower percentage of days with heavy alcohol consumption (7.8% versus 11.7%) in an imputed sample, when compared to placebo. Two types of alcoholics were identified. The type characterized by earlier problem drinking onset age, more family alcoholism, high severity of alcoholism, and fewer depressive symptoms, was associated with a greater chance of discontinuing treatment regardless of medication used and participation in alcoholic anonymous groups (AA). Out of the clinical and psychosocial variables, older age, AA attendance, and beer preference drinkers were independent factors associated with higher treatment retention. Higher scores on depression also increased the risk of dropout. CONCLUSION: Ondansetron showed to be safe and well tolerated at the dose of 16mg/day. It was more effective than placebo in delaying both the first use and the first heavy alcohol consumption. In addition, ondansetron was not effective in decreasing the percentage of drinking days throughout this study. The type of alcoholics characterized by earlier problem drinking onset age, more family alcoholism, high severity of alcoholism and fewer depressive symptoms, was associated with greater risk of dropout. Separately, the variables higher age, AA attendance, and beer preference increased the chance of completing the proposed treatments
538

Estabilização segmentar lombar e TENS na hérnia discal lombar: um ensaio clínico randomizado / Lumbar segmental stabilization and TENS in lumbar disc herniation: a randomized controlled trial

Fabio Jorge Renovato França 01 October 2013 (has links)
INTRODUÇÃO: A hérnia de disco lombar (HDL) acomete cerca de 5% dos pacientes com de dor lombar e o tratamento cirúrgico nestes casos é cada vez menos indicado, optando-se, na maior parte dos casos, pelo conservador. Embora o método estabilização lombar (EL) e a estimulação elétrica nervosa transcutânea (TENS) tenham mostrado bons resultados em indivíduos portadores de dor lombar inespecífica, há escassa literatura que tenha verificado a eficácia destes tratamentos isoladamente em sujeitos acometidos por hérnia de disco lombar. OBJETIVO: Comparar a eficácia dos exercícios de estabilização lombar e da TENS na dor, incapacidade funcional, e capacidade de ativação do músculo transverso do abdome (TrA) de indivíduos com hérnia de disco lombar. METODOLOGIA: Participaram da pesquisa 40 indivíduos com idade variando de 25 a 58 anos com dor lombar e hérnia de disco, e foram randomizados em dois grupos: Grupo estabilização lombar (EL) (exercícios específicos para os músculos TrA e multífido lombar(ML)) (n=20) e Grupo TENS (GT) (n=20) que receberam atendimento com corrente de estimulação elétrica nervosa transcutânea. Foram avaliados quanto à dor (Escala Visual Analógica e Questionário McGill de Dor), incapacidade funcional (Índice de Incapacidade de Oswestry), e capacidade de recrutamento do TrA (Unidade de Biofeedback Pressórico-UBP). Os grupos foram tratados em duas sessões semanais com duração de 60 minutos por oito semanas. Cada indivíduo foi avaliado antes e após o tratamento. O nível de significância estabelecido foi de alfa=0,05. RESULTADOS: Após oito semanas, o grupo estabilização lombar mostrou melhora significativa na dor (p < 0,001), incapacidade funcional (p < 0,001), e capacidade de ativação do TrA (p < 0,001). O grupo TENS apresentou diferença estatisticamente significante apenas na dor (p < 0,012). A estabilização foi superior à TENS na melhora na dor (p < 0,001), incapacidade funcional (p < 0,001), e capacidade de ativação do TrA (p < 0,001). CONCLUSÃO: Os resultados indicam que a estabilização é efetiva na melhora da dor, incapacidade funcional, e capacidade da ativação do TrA, e a TENS apenas na dor. A estabilização foi superior à TENS em todas as variáveis / INTRODUCTION: Lumbar disc herniation (LDH) affects about 5% of low back pain (LBP) patients. Surgical treatment in these cases is increasingly less suitable, opting, in most cases, for the conservative. Although lumbar stabilization method and transcutaneous electric nerve stimulation (TENS) have shown good results in patients with nonspecific low back pain, there is scarce literature that has verified the effectiveness of these treatments alone in subjects suffering from lumbar disc herniation.OBJECTIVE: To compare the effectiveness of lumbar stabilization exercises and transcutaneous electrical nerve stimulation (TENS), on pain, functional disability and activation of the transversus abdominis muscle (TrA), in individuals with lumbar disc herniation (LDH). METHODS: This study involved 40 patients (age range 25-58 years) with lumbar disc herniation randomized into two groups: Stabilization group (SG: n=20); which received of stabilization exercises (transversus abdominis and lumbar multifidus muscles) and TENS group (TG: n=20), which received electrotherapy. The following instruments were used: visual analogue pain scale and McGill Pain Questionnaire for pain, Oswestry Disability Index for functional disability, and pressure biofeedback unit (PBU) for ability to contract the TrA. Analyses within and between groups were performed after treatment. Groups underwent 16 sessions, for 60 minutes, twice a week and they were evaluated before and after eight weeks. Significance level was set at alfa= 0.05. RESULTS: After eight weeks, lumbar stabilization group showed significant improvements in pain (p < 0.001), functional disability (p < 0.001), and the ability to contract the TrA (p < 0.001). There were no significant differences in TENS group in terms of disability (p < 0.264) or ability to contract the TrA muscle (p < 0.181), however, improvement in pain was demonstrated (p < 0.012). The stabilization was superior to TENS in terms of improvements in pain (p < 0.001), functional disability (p < 0.001), and ability to contract the TrA (p < 0.001). CONCLUSION: The results indicate that stabilization is effective in improving pain, functional disability, and the ability to contract the TrA in individuals with LDH. In the TENS group, the only improvement after treatment was in terms of pain. Stabilization was superior to TENS in all outcomes
539

A gestão de redes de pesquisa científica, tecnológica e de inovação em saúde no Brasil / Managing Science, Technology and Innovation in Health Research Networks in Brazil

Marge Tenório 16 September 2016 (has links)
Esta tese se pautou nas interfaces entre a estrutura do Sistema Nacional de Inovação em Saúde e o Sistema Nacional de Saúde - componentes estratégicos para os setores econômico e social do país. Abordou-se o marco jurídico institucional que dá sustentação à Ciência e Tecnologia em Saúde, envolvendo o arcabouço político que ampara a inovação tecnológica no país e os sistemas de regulação voltados a garantir sua sustentabilidade. O propósito desta pesquisa foi o de investigar as relações e os padrões que possibilitam o estabelecimento de vínculos entre os atores e ainda favorecem a formação de redes de pesquisas, buscando identificar quais os elementos que necessitam de maior foco dos gestores de forma que as conexões estabelecidas sejam fortalecidas e facilitem o monitoramento e a avaliação das redes. Caracteriza-se por ser uma pesquisa qualitativa elaborada a partir da teoria crítica, de abordagem quantitativa, incluindo um estudo de caso exploratório e analítico sobre a Rede Nacional de Pesquisa Clínica em Hospitais de Ensino, envolvendo a triangulação de métodos, baseada na observação, na análise de conteúdo e na vertente bibliográfica. Apoiou-se nas bases da Teoria Ator-Rede, ao investigar as relações e os padrões, que acabam por se configurar como vínculos entre pesquisadores e instituições. Os resultados depreendidos do estudo acrescentam novas compreensões sobre a gestão de redes de pesquisas, cuja análise se encontra hoje permeada por uma literatura centrada em atributos individuais. Ao se perceber a pesquisa clínica multicêntrica como estratégica fomentadora de inovação para saúde, esta tese delineou alternativas de gestão para expandir as conexões relacionais passíveis de fomentar, ampliar e fortalecer o Sistema Nacional de Ciência, Tecnologia e Inovação em Saúde e suas associações com as necessidades do Sistema Único de Saúde / This thesis is based on the interfaces between the Brazilian National System for Innovation in Health\'s structure and the Brazilian National Health System - strategic components for the economic and social sectors in the country. The institutional legal framework that gives support to Science and Technology in Health was referred to, considering the policies that sustain technological innovation in the country and the regulatory systems aimed at guaranteeing its sustainability. The goal of this study was to investigate the relationships and the patterns that make it possible to establish ties between actors and that also favor the formation of research networks, seeking to identify which elements require a greater focus from managers in order to strengthen the established ties and to facilitate network monitoring and evaluation. This study is a qualitative one that is elaborated upon critical theory, upon a quantitative approach, and includes an exploratory and analytical case study on the Brazilian National Network of Clinical Research in Teaching Hospitals, comprising a triangulation of methods, based on observation, on content analysis and on bibliographic lines. Upon investigating relationships or patterns, this study relied upon the bases of Actor-Network Theory, which result in ties formed between researchers and institutions. The results gathered from the study added new insight into the management of research networks, whose analysis is currently permeated by literature centered on individual attributes. Upon perceiving multicenter clinical trials as a strategy that fortifies innovation in health, this thesis outlined management alternatives that may expand the relational connections believed to foment, increase and strengthen the Brazilian National Science, Technology and Innovation System and its associations with Brazilian Public Health System needs
540

Inovação e interação: as redes de ensaios clínicos e o Brasil / Innovation & interaction: clinical trials networks and Brazil

Robson Rocha de Oliveira 25 May 2018 (has links)
A inovação em saúde é caracterizada por uma forte interação com o setor de ciência e tecnologia. O crescente interesse pela internacionalização das atividades de Pesquisa e Desenvolvimento (P&D) conduz ao questionamento sobre as oportunidades em função das interações com outros países, como mecanismo para a construção de capacidades nacionais de inovação. Conforme os ensaios clínicos atravessaram as fronteiras nacionais, alcançando uma expressão global, as redes de relações entre os atores envolvidos torna-ram-se cada vez mais complexas e apresentam-se como uma possibilidade para a carac-terização da interação dos sistemas nacionais de inovação no plano global, particular-mente a partir do ponto de vista da produção de atividades de ciência, tecnologia e inovação em saúde. O objetivo deste trabalho foi estudar a expansão global de ensaios clíni-cos a fim de se mapear os possíveis padrões de conexão entre os países participantes, especificamente identificando a inserção do Brasil. Os métodos empregados incluíram pesquisa bibliográfica, análise de dados secundários, análise de redes sociais e entrevistas semiestruturadas com atores relacionados com a condução de ensaios clínicos no Brasil. Constata-se uma crescente interdependência dos sistemas nacionais de inovação, reque-rendo novas estruturas internacionais de inovação. Surgem novas oportunidades para a produção e a difusão internacional do conhecimento. Os ensaios clínicos promovem e requerem a interação entre empresas, universidades e instâncias governamentais, revelando-se como um elemento estratégico para a estruturação dos sistemas nacionais de inovação em saúde / Health innovation has been characterized by strong interaction with the science and technology sector. The growing interest in the internationalization of Research and Develop-ment (R&D) activities leads to a reflection on opportunities, in relation to connections among countries, as a mechanism for building national innovation capacities. Clinical trials have crossed national boundaries. As a result, the networks between the actors in-volved have become increasingly complex. That could be a possibility for characterizing the interaction of national innovation systems at the global level, particularly from the production of Science, Technology and Innovations activities in the health sector. The aim of this study was to assess the global expansion of clinical trials in order to map possible patterns of interaction among participating countries. The methods used included bibliographic research, secondary data analysis, social network analysis and semi-structured interviews with actors related to the conduction of clinical trials in Brazil. A growing interdependence of national innovation systems is based on new international inno-vation structures. New opportunities for the international diffusion of knowledge and production has been created. Clinical trials promote and require connections among firms, universities and government. Therefore, they represent a strategic element for national health innovation systems structuration

Page generated in 0.0222 seconds