• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 204
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 207
  • 94
  • 35
  • 28
  • 26
  • 22
  • 20
  • 20
  • 19
  • 19
  • 19
  • 18
  • 18
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Escore eletrocardiográfico para avaliação de isquemia miocárdica: aplicação em testes ergométricos sequenciais para avaliação do fenômeno do aquecimento / Electrocardiographic score for myocardial ischemia evaluation: application in sequential exercise tests for warm-up phenomenon evaluation

Augusto Hiroshi Uchida 18 December 2009 (has links)
O tempo para 1,0mm de depressão do segmento ST (T-1,0mm) adotado para caracterizar o fenômeno do aquecimento, uma expressão do precondicionamento isquêmico (PCI), em testes ergométricos sequenciais é consistente e reprodutível, porém, possui várias limitações. O objetivo deste estudo foi aplicar um escore eletrocardiográfico de isquemia miocárdica em testes ergométricos sequenciais comparando com o clássico índice T-1,0mm. Avaliamos 61 pacientes, com idade média de 62,2+7,5 anos, 86,9% homens, portadores de diabetes mellitus tipo 2 e coronariopatia multiarterial. Foram analisados 151 exames, destes 116 de pacientes completaram as duas fases de avaliação. A primeira fase compreendia dois testes ergométricos sequenciais para documentação do PCI e a segunda fase, após 1 semana, mais dois testes sob efeito de repaglinida oral. Dois observadores aplicaram o escore de forma cega. Observou-se concordância perfeita inter e intraobservador (Kendall Tau-b = 0,96, p<0,0001, Kendall Tau-b=0,98, p<0,0001, respectivamente). Os valores de sensibilidade, especificidade, valor preditivo negativo, valor preditivo positivo e acurácia, foram respectivamente de 72,41%, 89,29%, 75,8%, 87,5% e 81%. Concluímos que o escore de isquemia é um método consistente e reprodutível para documentação do fenômeno do aquecimento, representando uma alternativa factível ao índice T-1,0mm. / The time to 1.0mm ST-segment depression (T-1.0mm), adopted to document the warm-up phenomenon, an expression of the ischemic preconditioning (IPC), during sequential exercise tests is considered reliable and reproductible, although with several limitations. The main goal of this study was to apply an electrocardiographic ischemic myocardium score to sequential exercise tests, comparing with the standard T-1.0mm. We evaluated 61 patients, mean age 62,2+7,5 years-old, 86.9% male, with type 2 diabetes mellitus and multivessel coronary disease. We analyzed 151 exercise tests, being 116 tests from patients who fulfilled the two phases of the study. The first phase enrolled the patients for two sequential exercise tests to document the IPC and the second phase, after 1 week, two additional sequential exercise tests were performed under repaglinide treatment. We observed a perfect concordance inter and intraobserver (Kendall Tau-b=0.96, p<0.0001; Kendall Tau-b=0,98, p<0,0001, respectively). The sensibility, specificity, positive predictive value and negative predictive value were also determined: 72.41%, 89.29%, 75.8%, 87.5% and 81%, respectively. In conclusion, the electrocardiographic ischemic score is a consistent and reproductible tool to document the warm-up phenomenon, representing a reliable alternative to the T-1.0mm.
152

Comparação entre o teste ergométrico e a cintilografia miocárdica na avaliação do precondicionamento isquémico precoce. / The comparison between the exercise testing and myocardial scintigraphy in the assessment of early ischemic preconditiong.

Susimeire Buglia 19 April 2012 (has links)
O fenômeno do precondicionamento isquêmico é definido como o aumento da tolerância à isquemia e à lesão de reperfusão, induzida por curtos e sucessivos episódios de isquemia prévios a período de isquemia prolongada. A angina do aquecimento e a de pré-infarto são duas condições clínicas relacionadas ao precondicionamento. Este fenômeno apresenta duas fases distintas, clássica ou precoce e tardia. A atenuação do infradesnível do segmento ST provocada pelo precondicionamento precoce está bem documentada, porém sua expressão cintilográfica permanece controversa. O objetivo desta pesquisa foi avaliar se as atenuações eletrocardiográficas do precondicionamento durante testes sequenciais estão associadas a modificações simultâneas das imagens de cintilografia de perfusão miocárdica em indivíduos com doença coronariana. Vinte e três pacientes foram selecionados entre março de 2009 e julho de 2011. A média de idade foi 64,5 anos (dp=7,0), 19 (82,6%) do sexo masculino e todos tinham lesão coronária em pelo menos um vaso superior a 60%. A medicação antiisquêmica foi suspensa por três a cinco dias. Os pacientes foram submetidos a três testes ergométricos a partir do exame de seleção, sendo dois deles sequenciais e o terceiro realizado após sete dias. A injeção do radiofármaco sestamibi-Tc-99m no teste de precondicionamento e contraprova foi administrado no tempo de aparecimento do infradesnível de ST de -2,0 mm na derivação MC5 e/ou dor precordial anotados no teste inicial ou de seleção. A imagem cintilográfica foi adquirida entre 60 a 90 minutos após o esforço. Os resultados do segundo teste (precondicionamento) mostraram aumento significativo do tempo para o aparecimento da depressão do segmento ST de 1,0 mm (338±130) e 2,0 mm (431±126), em relação ao teste inicial (245±96; 366±103) p<0,001. A diferença na redução do valor máximo de infradesnível de ST entre os três testes foi significativa (3,8±0,8; 2,3±0,6; 3,1±1,0) p<0,001. Houve redução significativa nos escores de perfusão de estresse (p=0,045) entre o primeiro e o segundo testes, bem como para o escore da diferença entre o estresse e repouso (p= 0,03), sem diferença na extensão da área de isquemia entre as três etapas detectadas pela cintilografia (p=0,691). Em conclusão, houve redução significativa das alterações eletrocardiográficas induzidas pelo precondicionamento isquêmico precoce em maior proporção do que as observadas nas respectivas imagens de cintilografia de perfusão miocárdica; não se observou associação entre a redução da depressão do ST e a redução do escore de perfusão na fase de precondicionamento, nem correlação entre a magnitude do infradesnível máximo de ST e a redução do escore de perfusão (r=0,07 e p=0,75). / The phenomenon of ischemic preconditioning is defined as the increase of tolerance to ischemia and injury of reperfusion induced by short and consecutive episodes of isquemia prior to prolonged arterial occlusion. Warm-up and pre-infarction angina are two clinical conditions regarding this phenomenon. The ischemic preconditioning has two distinct windows designed as classical and late. The improvement of ST depression induced by classical preconditioning is well documented, however its scintigraphy expression is still controversial. The aim of this research was to assess whether the reduction of ST depression induced by preconditioning during these sequencial exercise testing are associated to simultaneous alterations of the scintigraphy images of myocardial perfusion in individuals with coronary artery disease. From March 2009 to July 2011, 23 patients were selected, mean age 64,5 (sd=7,0), 19(82,6%) male. All patients had coronary artery stenosis at least 60% in one vessel. The anti ischemic therapy was discontinued for three days. Patients underwent three exercises testing after screening process; two of these tests were in a sequence and the other one performed after seven days. Tc-99m-sestamibi radiotracer injection was applied in the preconditioning test as well as for the third test at the time of development of ST depression 2,0 mm in the CM5 lead and/or chest pain estabilished in the screening process or first test. The scintigraphy image was obtained from 60 to 90 minutes after exertion. The results of the preconditioning test showed a significant increase of time for manifestation of the ST depression 1,0 mm (338±130) and 2,0 mm (431±126) regarding the first test (245±96; 366±103), p<0,001. There was a significant difference in the decrease of maximum value of ST depression among the three tests (3,8±0,8; 2,3±0,6; 3,1±1,0), p<0,001. A significant reduction in stress perfusion score (p=0,045) occurred between the first and second test as well as for the difference score between stress and rest (p=0,03). However, there was not a significant difference in the total defect size among the three stages detected by myocardial scintigraphy (p=0,691). In conclusion, there was a significant decrease of electrocardiographic alterations resulting from early preconditioning in greater proportion than the observed in scintigraphy images. It was not observed an association between the decrease of ST depression with the stress perfusion score during the preconditioning period nor the correlation between the magnitude of the maximum value of ST depression and the decrease of perfusion score (r=0,07 and p=0,75).
153

Acurácia do gravador de eventos do marcapasso cardíaco artificial versus Holter na detecção de arritmias ventriculares sintomáticas e assintomáticas / Accuracy of the artificial pacemakers monitoring system versus 72h Holter in the detection of symptomatic and asymptomatic ventricular arrhythmias

Stela Maria Vitorino Sampaio 30 September 2015 (has links)
O sistema Holter é considerado padrão ouro para detecção de arritmias cardíacas, possibilitando o seu diagnóstico e sua relação com os sintomas do paciente. As novas gerações de marcapassos (MP) detectam e registram eletrogramas intracavitários e poderiam dispensar o Holter no seguimento dos pacientes. Os diferentes MP dispõem de algoritmos de detecção de arritmias ventriculares (AV) que variam de acordo com o modelo e sua correlação diagnóstica com Holter foi pouco estudada. O objetivo desse estudo foi avaliar 1. a correlação entre o monitor de eventos dos MP e do Holter na detecção de AV e 2. a concordância das AV detectadas nos dois sistemas. Foram estudados129 pacientes portadores de MP com função de detecção de arritmias, com idade média de 68,6+19.1 anos (entre 19 e 94), 54,8% do sexo feminino. Os pacientes foram submetidos à monitorização com Holter por 72 horas. Assim que o sistema foi ligado, os contadores de eventos dos marcapassos foram reiniciados e os relógios sincronizados, para que ambos os sistemas detectassem os eventos simultaneamente. Os MP foram programados para detecção de eventos com o menor valor de frequência ventricular (FV) e o menor número de batimentos sequenciais (BT) possíveis. Depois de 72 horas, os sistemas Holter foram retirados e os registros analisados, assim como os registros simultâneos dos gravadores dos MP. Foram qualificados como eventos arrítmicos no Holter e MP, respectivamente: EV isoladas e \"PVC\"; extra-sístoles em pares e \"couplets\"; TVNS (> 3BT) e \"triplets\"(3BT), \"runs\"(3 a 8 ou > 8 BT) e \"HVR\" (3 ou 4 BT). As correlações de Spearman foram utilizadas para avaliar se o marcapasso acompanha a detecção dos parâmetros do Holter. Os coeficientes de correlação intraclasse e os respectivos intervalos com 95% de confiança, calculados para avaliar a concordâncias entre os parâmetros equivalentes do marcapasso e do Holter. Foram calculados os coeficientes Kappa para avaliar a concordância na detecção de > 10 \"PVC\"/h com > 10 EV/h. Resultados: Os monitores dos marcapassos subestimaram o Holter. Os registros de \"PVC\", \"triplet\" e \"HVR\" por TVNS apresentaram correlações positivas em relação aos parâmetros do Holter, sendo a mais alta aquela entre \"PVC\" e EV (r=0,501). Porém, a concordância entre os tipos de arritmias detectadas foi baixa (CCI < 0,5), exceção feita à concordância de \"triplet\" com TVNS de três batimentos (CCI=0.984). A concordância na detecção de mais de 10 PVC/h e mais de 10 EV/h foi moderada (kappa= 0,483), embora para os MP da Medtronic, o coeficiente de concordância foi alto (kappa=0.877). Para os MP com algoritmo de detecção de sequências de três batimentos com FV menor que 140bpm ( < 140/3), a correlação entre HVR e TVNS foi expressiva (r = 1), sendo a concordância entre esses parâmetros também bastante alta (CCI = 0,800). Conclusões: A correlação e a concordância na detecção de AV registradas nos MP e no Holter foram inconsistentes. Padronização dos algoritmos de detecção de AV, semelhantes os do sistema Holter, é necessária para que os pacientes portadores de dispositivos implantáveis possam se beneficiar dessa função para seguimento clínico e estratificação de risco / The Holter monitoring is considered the gold standard method for detection of cardiac arrhythmias, enabling its diagnosis and its correlation with the patient\'s symptoms. New generations of artificial pacemakers can detect and record intracavitary electrograms and, theoretically, could discard the Holter during the follow-up of the patients. Pacemakers have different ventricular arrhythmias (VA) detection algorithms, varying according to the model. Their diagnosis capacity comparing to Holter monitoring has been poorly studied. The aim of this study was to evaluate 1. the correlation between the event monitor of the pacemaker and the Holter in VA detection and 2. the agreement between the VA detected in both systems. We studied 129 patients with implanted pacemakers, which had arrhythmia detection function, mean age of 68.6 + 19.1 years (19 to 94), 54.8% female. The patients underwent Holter monitoring for 72 hours. Once the system was connected, event counters of pacemakers were reset and the clocks synchronized, so that both systems could detect the arrhythmic events simultaneously. The pacemakers were programmed to detect events with the lowest ventricular rate and lowest number of sequential beats allowed for each model. After 72 hours, Holter systems were removed and the records analyzed, as well as the simultaneous records of the pacemakers. Were considered as arrhythmic events: PVC isolated (in the pacemaker described as \"PVC\"); premature beats in pairs (pacemaker described as \"couplets\"); NSVT (pacemaker described as \"triplets\"- 3beats, \"runs\"- 4 to 8 or > 8 beats and \"HVR\"- 3 to 4 beats). Spearman rank correlations were used to assess whether the pacemaker and Holter identified the same parameters. The intraclass correlation coefficients and the respective intervals with 95% confidence were calculated to evaluate the concordance between the equivalent parameters of the pacemaker and Holter. Kappa coefficients were calculated to assess the agreement in the detection of > 10 PVC/h by the pacemakers and by the Holter. Results: The pacemakers underestimated the arrhythmias detection of Holter. Records of \"PVC\", \"triplet\" and \"HVR\" by NSVT showed positive correlations with the Holter parameters, and the highest one was among \"PVC\" and EV (r = 0.501). The agreement between the types of arrhythmias detected was quite low (CCI < 0.5), except for \"triplet\" detected by pacemakers and three beats NSVT by Holter (ICC = 0.984). The correlation detection for more than 10 PVC /h was moderate (kappa = 0.483), except for Medtronic pacemakers (kappa=0.877). When the pacemaker was programmed to detect sequences of three beats with heart rate lower than 140bpm ( < 140/3), the correlation between HVR and NSVT was perfect (r = 1) and the agreement between these parameters was also quite high (ICC = 0.800). Conclusions: The correlation and agreement between pacemakers and Holter monitoring in the detection of VA were not consistent. A standardization of the pacemakers\' detection algorithms is necessary before using this function for clinical follow-up and risk stratification of the patients
154

"Estudo comparativo de diferentes métodos eletrocardiográficos de diagnóstico de hipertrofia ventricular esquerda e sua associação com característica anatômicas e histológicas do coração" / A comparative study of different electrocardiographic methods for the diagnosis of left ventricular hypertrophy and its association with both anatomic and histological characteristics of the heart

Júlio César Ronconi 27 June 2005 (has links)
A hipertrofia ventricular esquerda (HVE) é importante fator de risco cardiovascular. O objetivo deste estudo retrospectivo foi verificar a associação de critérios eletrocardiográficos de HVE com as características anatômicas e histológicas do coração, em 51 pacientes submetidos à necropsia. Procedeu-se à medição do diâmetro transverso dos cardiomiócitos e da porcentagem de fibrose do ventrículo esquerdo e direito. Entre os pacientes que apresentavam HVE anatômica, o critério de Romhilt foi positivo em 92,3%, sendo superior aos demais critérios avaliados, com especificidade de 89,5% e sensibilidade de 68,8%, Foi o único que se associou a características anatômicas e histológicas do coração / The left ventricular hypertrophy (LVH) is an important cardiovascular risk factor. The purpose of the present retrospective paper is to examine the association of LVH electrocardiographic criteria with both anatomical and histological characteristics of the heart on 51 patients submitted to the necropsy. The study carried out the measurement of the transverse diameter of cardiomyocytes, as well as the percentage of fibrosis at both left and right ventriculi. Among those patients who presented anatomic LVH, the Romhilt criterium resulted positive in 92.3% of the cases, thus surpassing the other criteria evaluated, with specificity and sensibility up to 89.5% and 68.8% respectively. This was the only criterium associated to both anatomic and histological characteristics of the heart
155

Estudo da repolarização ventricular em pacientes submetidos à terapia de ressincronização cardíaca, portadores de bloqueio de ramo esquerdo e insuficiência cardíaca, através do mapeamento eletrocardiográfico de superfície / Study of ventricular repolarization in patients with bundlebranch block and heart failure, undergoing cardiac resynchronization therapy, by body surface potential mapping

Roberto Andrés Gomez Douglas 31 May 2011 (has links)
INTRODUÇÃO: A terapia de ressincronização cardíaca (TRC) é procedimento já incorporado às diretrizes do tratamento da insuficiência cardíaca crônica grave. Os efeitos sobre a repolarização ventricular são controversos e seu comportamento ainda precisa ser melhor definido por meios não invasivos. OBJETIVO: Analisar o comportamento da repolarização ventricular, através do mapeamento eletrocardiográfico de superfície (MES), em pacientes sob TRC. MÉTODOS: Foram estudados 52 pacientes sob TRC com indicação classe I das Diretrizes Brasileiras de Dispositivos Cardíacos Eletrônicos Implantáveis-2007, com idade média 58,8±12,3 anos, 31 homens, FEVE:27,5±9,2 e QRS:181,5±24,2ms. Foram excluídos os que não eram classe I e também os que usavam amiodarona, portadores de fibrilação atrial, marcapasso ou CDI prévios. O MES de 87 derivações (59 no tórax anterior e 28 no dorso) foi realizado em ritmo sinusal (BASAL) e sob efeito do ressincronizador (BIV) Através de medidas semiautomáticas foram obtidos o intervalo QT, QTc médio e a dispersão de QT (DQT) global das 87 derivações, nos dois modos de estimulação, em cada paciente. As mesmas medidas foram realizadas e comparadas nas três regiões discriminadas pelo MES (VD, Septo e VE). Caracterizamos assim, o comportamento global e regional do QT e sua dispersão na TRC. Utilizamos os testes t Student pareado e ANOVA para comparações múltiplas. Nível de significância de p< 0,05. RESULTADOS: O comportamento global do QTmédio foi sensivelmente menor em BIV que no BASAL (424,4±38,7 x 455,8±46,5ms; p<0,001), assim como o QTc médio (460,7±42,3 x 483,8±41,4ms; p<0,05) e a DQT (61,2±26,2 x 74,9±28,7ms; p<0,05). O QTmédio foi semelhante nas 3 regiões nos modos BASAL e BIV (p=ns), porém o QTc médio nas regiõess VD e VE mostrou-se significantemente menor no modo BASAL. Sob BIV, essa diferença foi notavelmente menor na região do VD. A DQT, em região do VE, por sua vez, foi significantemente menor em relação ao Septo, nos dois modos (BASAL: 40,5±23,1 x 55,7±28,7ms, p<0,01 e BIV: 30,6±20,4 x 47,1±20,2ms, p<0,001). A variação de efeito (D%) da TRC determinou redução do QTmédio nas 3 regiões (VD: p=0,0014; Septo: p=0,0001 e VE: p=0,0018), enquanto a DQT reduziu-se em VD: p=0,04 e VE: p=0,023. Em região septal, a redução da DQT não atingiu significância, embora tenha mostrado a mesma tendência de resposta. CONCLUSÃO: O Mapeamento Eletrocardiográfico de Superfície detectou redução global e regional dos valores da repolarização ventricular, através da análise do QTm, QTcm e DQT, por efeito da terapia de ressincronização cardíaca em pacientes com insuficiência cardíaca grave e BRE / BACKGROUND: Cardiac resynchronization therapy (CRT) is an already established procedure, which became part of the guidelines for severe chronic heart failure treatment. Its effects upon the ventricular repolarization are controversial, therefore CRT response still remains to be better defined by noninvasive methods. OBJECTIVE: The aim of this study was to analyze the ventricular repolarization response by body surface potential mapping (BSPM) in patients undergoing CRT. METHODS: Fifty-two patients undergoing CRT, mean age 58.8±12.3 years, 31 male, LVEF 27.5±9.2 and QRS duration 181.5±14.2ms, with indication class I of the 2007Guidelines for Implantable Electronic Cardiac Devices of the Brazilian Society of Cardiology, were studied. Those who were not in class I and/or in use of amiodarone, with atrial fibrillation, or with previous pacemaker or ICD, were excluded. Eighty-seven-lead BSPM examination (59 leads on the anterior chest and 28 on the back) was performed in sinus rhythm (BASELINE), and in biventricular pacing (BIV) with the resynchronization device on. Global values of QT and mean QTc intervals, and QT dispersion (DQT) were semiautomatically measured in all patients in the two pacing modes. Same measurements were made and compared in the three regions (RV, Septum and LV) discriminated by BSPM maps. Thus we characterized the global and regional QT response and its dispersion under CRT. t-Student paired test and ANOVA were used for multiple comparisons. Significance level: p<.05. RESULTS: The global mean QT response was considerably smaller in BIV pacing than in BASELINE (424.4±38.7 x 455.8±46.5ms; p<.001), and so were the mean QTc (460.7±42.3 x 483.8±41.4ms; p<.05) and DQT (61.2±26.2 x 74.9±28.7ms; p<.05). Mean QT was similar across the three regions in both pacing modes (p=ns); however, mean QTc in RV and LV regions was found to be significantly smaller in BASELINE. In BIV pacing such difference was considerably smaller in the RV region. On the other hand, DQT value in the LV region was significantly smaller compared to the Septum region in both modes (BASELINE 40.5±23.1 x 55.7±28.7ms. p<.01; and BIV 30.6±20.4 x 47.1±20.2ms. p<.001). Variation of CRT effect (D%) determined reduction of mean QT in the three regions, RV (p=.0014); Septum (p=.0001); and LV (p=.0018), while DQT was reduced in RV (p=.04) and LV (p=.023) regions. DQT reduction in the septal region was not significant, although it showed the same trend of response. CONCLUSION: body surface potential mapping detected reduction of global and regional ventricular repolarization values by analyzing QTm, QTcm and DQT variables under the effect of cardiac resynchronization therapy, in patients with severe heart failure and LBBB
156

Eventos arrítmicos em pacientes com canalopatias cardíacas submetidos à anestesia local odontológica: estudo piloto randomizado / Arrhythmic events in patients with cardiac channelopathies subjected to local dental anesthesia: a randomized pilot study

Oliveira, Ana Carolina Guimarães 14 May 2019 (has links)
Introdução: Distúrbios dos canais iônicos cardíacos potencialmente letais, como a síndrome de Brugada (SBr), a síndrome do QT longo congênito (SQTL) e a taquicardia ventricular polimórfica catecolaminérgica (TVPC) podem ser responsáveis por pelo menos um terço do total de casos de morte súbita que permanecem inexplicados. Estes pacientes, por vezes, não obtêm tratamento odontológico e analgesia adequados devido à falta de informações na literatura em relação à dose e tipo de anestésico local recomendado, e ao risco potencial de eventos cardíacos ameaçadores à vida e instabilidade hemodinâmica. Métodos: Trata-se de um estudo piloto, randomizado, duplo-cego e cruzado com portadores de canalopatias cardíacas submetidos a tratamento odontológico restaurador em duas sessões, realizadas com intervalo mínimo de sete dias (wash-out) entre ambas, sendo o paciente seu próprio controle. Na primeira sessão, por randomização, o paciente recebeu uma das soluções anestésicas: lidocaína 2% sem vasoconstritor (LSA) ou lidocaína 2% com adrenalina 1:100.000 (LCA), originando duas condições: sem adrenalina e com adrenalina; na segunda sessão recebeu o outro anestésico. Todos foram monitorados com Holter por 28 horas, contadas a partir de uma hora antes do procedimento, nas duas sessões do estudo. Durante o atendimento odontológico, foram feitos registros pontuais em três momentos por meio de eletrocardiograma de 12 derivações, esfigmomanômetro digital para pressão arterial e escala de mensuração da ansiedade. Resultados: Sessenta e dois procedimentos restauradores foram realizados em 31 pacientes: 16 (51,6%) tinham SQTL, 12 (38,7%) SBr e três (9,7%) TVPC, dentre os quais 12 (38,7%) eram portadores de cardiodesfibrilador implantável. A idade média dos pacientes foi 45,2+15,8 anos, sendo 21 (67,7%) do sexo feminino. Os valores médios da frequência cardíaca máxima se mostraram aumentados com o uso de LCA no período da anestesia (84,4 x 80,4 bpm; p=0,005) com diferença estatisticamente significante entre as duas condições, assim como o QTc em pacientes com SQTL (465,4 x 450,1; p=0,009). Valores de pressão arterial e mensuração da ansiedade não mostraram diferença estatisticamente significante. Não foram observadas arritmias ventriculares ameaçadoras à vida durante os procedimentos. Conclusões: O uso da anestesia local com lidocaína, independente do uso de vasoconstritor, não resultou em arritmias ameaçadoras à vida e foi considerado seguro nos pacientes selecionados. Estes resultados preliminares devem ser confirmados em uma população maior, em um estudo multicêntrico / Background: Ion channel disorders, such as Brugada syndrome (BS), long QT syndrome (LQTS), and catecholaminergic polymorphic ventricular tachycardia (CPVT), may account for at least one-third of unexplained sudden cardiac deaths. These patients often do not receive adequate dental treatment and analgesia owing to the lack of information in the literature regarding the dose and type of local anesthetic recommended, and due to the potential risk of life-threatening cardiac events. Methods: This is a randomized, double-blind pilot trial in patients with cardiac CCh underwent to restorative dental treatment in two sessions, with a wash-out period of 7 days (crossover trial). In the first session, by randomization, the patient received one of the anesthetic solutions: 2% lidocaine without vasoconstrictor (LSA) or 2% lidocaine with epinephrine 1: 100,000 (LCA), making two conditions: without epinephrine and with epinephrine; and in the second session received the other anesthetic. Twenty-eight-hour Holter monitoring was performed in all patients, initiated one hour before the procedure, in the two study sessions. During the dental treatment, additional specific monitoring including 12-lead electrocardiography (ECG), digital sphygmomanometry and anxiety scale assessments was also applied at three time points. Results: Sixty-two dental procedures were performed in 31 patients with CCh: 16 (51.6%) had LQTS, 12 (38.7%) had BS and three (9.7%) had CPVT; 12 (38.7%) patients had an implantable defibrillator. The mean age was 45.2+15.8 years, and 21 (67.7%) patients were female. The maximum heart rate was increased after the use of epinephrine during the anesthesia period (84,4 x 80,4 bpm, p=0.005), as well the corrected QT in LQTS patients (465,4 x 450,1; p=0,009). Blood pressure and anxiety measurements showed no statistically significant differences. No life-threatening arrhythmias occurred during the dental treatment. Conclusions: The use of local dental anesthesia with lidocaine, regardless of the use of a vasoconstrictor, did not result in life-threatening arrhythmias and was considered safe in these selected patients with channelopathies. These preliminary findings need to be confirmed in a larger population study, in a multicenter study
157

Avaliação dos eventos arrítmicos em candidatos a transplante renal pela monitorização cardíaca com looper implantável / Long-term recording of arrhythmic events with implantable cardiac monitor in renal transplant candidates

Silva, Rodrigo Tavares 22 August 2011 (has links)
INTRODUÇÃO: pacientes com doença renal crônica em diálise apresentam elevada mortalidade anual, principalmente decorrente de eventos cardiovasculares, com destaque para morte súbita cardíaca (MSC). Os eventos arrítmicos (EA) são considerados os principais responsáveis pela MSC, tornando relevante a sua avaliação. Dispositivos cardíacos modernos como o looper implantável, que tem capacidade de monitorar o ritmo cardíaco por longo período de tempo e diagnosticar EA, podem contribuir na estratificação de risco desta população. OBJETIVOS: avaliar a taxa de ocorrência dos EA em candidatos a transplante renal com looper implantável e identificar fatores associados; determinar a significância prognóstica dos EA na MSC e mortalidade total; avaliar eficiência diagnóstica do looper e o papel da diálise. MÉTODOS: estudo clínico observacional, prospectivo e aberto que incluiu cem candidatos a transplante renal, em hemodiálise e com alto risco para transplante (idade >=50 anos, DM ou doença cardiovascular). Entre junho/2009 e janeiro/2010, os pacientes foram submetidos ao implante do looper para detecção dos EA e seguimento clínico de um ano. A idade média do grupo foi 59 anos; 65% homens; 97% hipertensos, 70% diabéticos, 34% com infarto prévio e tempo médio de 53,8 meses em hemodiálise. O diagnóstico dos EA seguiu protocolo específico e foram descritos todos os eventos clínicos fatais e não fatais. A estatística incluiu: análise descritiva dos EA, associação destes com variáveis exploratórias pelos testes de qui-quadrado, exato de Fischer, t-Student, Mann-Whitney e regressão logística stepwise selection para análise multivariada (p<0,05). RESULTADOS: foram diagnosticados 5075 EA em 98 pacientes em seguimento médio de 425 dias. A taxa de ocorrência dos EA na casuística foi: bradiarritmias (25%), arritmias supraventriculares (94%) e arritmias ventriculares (79%). Os EA mais comuns foram: taquicardia sinusal (39%) e atrial não sustentada (27%), extrassístoles ventriculares e atriais isoladas (16% e 5,4%) e taquicardia ventricular não sustentada (TVNS - 5,3%). Foram preditores para ocorrência dos EA: duração intervalo PR (p=0,0008; OR=1,05; IC-95%=1,02-1,08) e QT longo (p=0,002; OR=7,28; IC- 95%=2,01-26,35) para bradiarritmias; duração intervalo QTc (p=0,022; OR=1,02; IC-95%=1,01-1,04) e presença de insuficiência cardíaca (p=0,034; OR=9,87; IC- 95%=1,17-82,79) para arritmias ventriculares e dilatação ventricular esquerda (p=0,041; OR=2,83; IC-95%=1,01-7,96) para TVNS. Ocorreram 35 eventos clínicos não fatais, 14 transplantes renais e 18 óbitos. Dentre os óbitos, 38,9% foram cardiovasculares súbitos: quatro arritmogênicos, um IAM e dois indeterminados. Não houve associação entre EA e eventos fatais; fibrilação atrial e bradiarritmias tiveram associação significativa com eventos não fatais. O mecanismo de morte (arritmogênico) foi elucidado pelo looper em quatro pacientes com MSC; um paciente apresentou bloqueio atrioventricular e necessitou de marca-passo. A taxa de EA foi superior no período intradiálise em comparação ao interdiálise (p<0,001). CONCLUSÕES: neste estudo, que avaliou a monitorização cardíaca prolongada com looper implantável em candidatos a transplante renal, a taxa de ocorrência de EA foi elevada; foram preditores dos EA: a duração intervalo PR e presença de QT longo para bradiarritmias, duração intervalo QTc e insuficiência cardíaca para arritmias ventriculares e dilatação ventricular para TVNS; a taxa de mortalidade foi elevada, com importante contribuição da MSC; não houve associação entre EA e mortalidade total ou súbita; houve associação entre as bradiarritmias e a fibrilação atrial com a ocorrência de eventos não fatais; os EA foram mais frequentes no período intradiálise; o looper implantável foi eficiente na elucidação diagnóstica, com poucas complicações. / INTRODUCTION: chronic kidney disease patients undergoing dialysis have a high annual mortality rate, mainly due to cardiovascular disease. Sudden cardiac death (SCD), attributed to arrhythmic mechanisms, is considered the major cause of these high death rates. The implantable loop recorder (ILR), a modern cardiac device has the ability for long-term cardiac rhythm monitoring and diagnosing arrhythmic events (AE), which in fact may contribute to the risk stratification of this population. OBJECTIVES: this study was designed to evaluate the incidence and predictors of AE in renal transplant candidates with ILR; to determine the prognostic significance of AE in SCD and all-cause mortality, evaluate the diagnostic effectiveness of ILR and the role of dialysis. METHODS: a prospective, open, observational clinical study was conducted, including one hundred renal transplant candidates undergoing hemodialysis, at high risk for transplantation (age >=50 years, diabetes or cardiovascular disease). Between June/2009 and January/2010, patients received an ILR for detection of AE with a one-year follow-up. Mean age of the group was 59 years; 65% were men; 97% hypertensive, 70% diabetic, 34% had previous myocardial infarction and mean hemodialysis time was 53.8 months. The diagnosis of AE followed specific protocol and all fatal and non-fatal clinical events were described. The statistical analysis included: descriptive analysis of AE, an association between these events and exploratory variables by chi-square tests, Fisher exact test, Student\'s t test, Mann-Whitney test and logistic regression using stepwise selection for multivariate analysis (p<0.05). RESULTS: during mean follow-up of 425 days, 5075 AE were diagnosed by ILR in 98 patients. The rate of occurrence of EA in this patients was: bradyarrhythmias (25%), supraventricular arrhythmias (94%) and ventricular arrhythmias (79%). The most common AE were: sinus tachycardia (39%), nonsustained atrial tachycardia (27%), isolated premature ventricular beats (16%), isolated premature atrial beats (5.4%) and nonsustained ventricular tachycardia (NSVT - 5.3%). Predictors for the occurrence of AE were: duration of PR interval (p=0.0008; OR=1.05; 95%CI=1.02-1.08) and long QT (p=0.002; OR=7.28; 95%CI=2.01-26.35) for bradyarrhythmia; duration of QTc interval (p=0.022; OR=1.02; 95%CI=1.01-1.04) and presence of heart failure (p=0.034; OR=9.87; 95%CI=1.17-82.79) for ventricular arrhythmia and left ventricular dilatation (p=0.041; OR=2.83; 95%CI=1.01-7.96) for NSVT. There were 35 non-fatal clinical events, 14 renal transplantations and 18 deaths during follow-up. Regarding causes of death, 38.9% were due to sudden cardiovascular event: four were arrhythmogenic, one resulted from acute myocardial infarction and two were indeterminate. There was no association between AE and all cause or sudden mortality; bradyarrhythmias and atrial fibrillation were associated with the occurrence of non-fatal clinical events. The mechanism of death (arrhythmogenic) was elucidated by ILR in four patients with SCD; one patient had atrioventricular block and required pacemaker insertion. The rate of AE was higher in the intradyalitic period compared to interdialytic (p <0.001). CONCLUSIONS: in this study, which evaluate long-term cardiac rhythm monitoring with ILR in renal transplant candidates, the incidence of AE was high; predictors for the occurrence of AE were: duration of PR interval and presence of long QT for bradyarrhythmia, duration of QTc interval and heart failure for ventricular arrhythmia and left ventricular dilatation for NSVT; mortality rate was high and SCD made an important contribution. There was no association between AE and all-cause mortality and SCD; bradyarrhythmias and atrial fibrillation were associated with non-fatal events; the EA rate was higher at intradialytic period; the ILR was efficient in elucidating diagnoses and had few complications.
158

Impacto do uso rápido dos betabloqueadores sobre a mortalidade e remodelamento ventricular na insuficiência cardíaca avançada / Impact of rapid beta-blockers therapy on mortality and ventricular remodeling in advanced heart failure

Melo, Domingos Sávio Barbosa de 25 March 2011 (has links)
Fundamento: A terapia com betabloqueadores é fundamental para o tratamento da insuficiência cardíaca congestiva. Entretanto, apesar dos dados que documentam os benefícios dos betabloqueadores, a otimização da dose desses medicamentos durante a hospitalização ainda não foi testada. Objetivos: Avaliar a segurança da efetividade do betabloqueio rápido em pacientes hospitalizados por Insuficiência Cardíaca avançada. Métodos: Em estudo clínico randomizado, foram incluídos 92 pacientes com insuficiência cardíaca e fração de ejeção do ventrículo esquerdo <45%: 46 no grupo tratamento e 46 no grupo controle. Do total 59 (64,1%) pacientes eram do sexo masculino, com idade média de 62,25±14,43 anos. Durante o período de internação esses pacientes foram alocados aleatoriamente para receber incrementos da dose de betabloqueadores de forma rápida, a cada dois dias (grupo tratamento), ou a cada 15 dias (grupo controle). O desfecho principal foi a ocorrência de reinternação ou morte por causas diferentes. Foram considerados como efeitos adversos hipotensão arterial, bradicardia e piora da insuficiência cardíaca. Resultados: A fração de ejeção média do ventrículo esquerdo foi de 27,24±9,08, o diâmetro diastólico final médio 66,15±8,65 e o diâmetro sistólico final médio 57,04±9,96. No grupo tratamento, houve redução significativa do DSFVE em três meses e um ano (p<0,001), enquanto no grupo controle permaneceu inalterado (p=0,337). O DDFVE apresentou redução significativa (p=0,036) no grupo tratamento que não foi significativa no grupo controle (p=0,250). Houve aumento significativo da FEVE no grupo tratamento (p<0,001) em três meses, o que não ocorreu no grupo controle (p=0,151), mas não houve diferença entre os grupos em um ano. A distância percorrida no teste de caminhada de 6min aumentou significativamente (p<0,001) no grupo tratamento em relação ao grupo controle. O grupo tratamento apresentou probabilidade livre de internação significativamente maior que a do grupo controle (p=0,045). Com referência à sobrevida, o grupo tratamento apresentou níveis significativamente maiores que a do grupo controle no período avaliado (p=0,002). Conclusões: O incremento rápido da dose de betabloqueador durante a internação por descompensação de insuficiência cardíaca foi segura e melhorou a sobrevida, o remodelamento ventricular e a capacidade de fazer exercícios / Background: The beta-blocker therapy is essential in congestive heart failure treatment. However, despite data documenting, the benefits of beta-blockers, and the optimization of these medications dosage during hospitalization has not been tested. Objectives: To evaluate the safety of the efficiency of acute beta-blockade on hospitalized patients due to advanced heart failure. Methods: In a randomized clinical trial, 92 patients with heart failure and ejection fraction of left ventricle <45% were included: 46 in the treatment group and 46 in the control group. In the assessed group 59 (64.1%) patients were male, with mean age of 62.25 ± 14.43 years. During the hospitalization period and those who were randomized to acute beta-blocker dose increments, every other day (treatment group) or every 15 days (control group) were selected. The main outcome was the occurrence of rehospitalization or death for different causes. Hypotension, bradycardia, and worsening heart failure were considered as adverse effects. Results: The mean ejection fraction of left ventricle was 27.24±9.08, the average end-diastolic diameter 66.15±8.65 and the average end-systolic diameter 57.04±9.96. In the treatment group, significant reduction of DSFVE in three months and one year (p<0.001) has been observed, whereas in the control group remained unchanged (p=0.337). The LVEDD decreased significantly (p=0.036) in the treatment group and in the control group it was not significant (p=0.250). There was a significant increase of the LVEF in the treatment group (p<0.001) in three months, and no difference occurred in the control group (p=0.151), and no difference between groups in a year was observed. During the 6 min walking test the treatment group showed a significant distance increase (p<0.001) when compared with the control group. The treatment group had free admission probability significantly higher than the control group (p=0.045). As to patients survival, the treatment group showed significantly higher levels than the control group during the evaluation period (p=0.002). Conclusions: Fast increase of the beta-blockers dosage during hospitalization in decompensated heart failure was safe and improved survival, ventricular remodeling, and exercise capacity
159

Estudo das alterações da variabilidade da freqüência cardíaca e troponina no paciente séptico / Heart rate variability and troponin in septic patients

Nogueira, Antonio Carlos 24 April 2006 (has links)
CONTEXTO: Estudos observacionais têm demonstrado alterações na variabilidade da freqüência cardíaca em pacientes em sepse, embora não exista publicação correlacionando lesão cardíaca causada pela inflamação sistêmica e redução da variabilidade da freqüência cardíaca. OBJETIVOS: Determinar, em pacientes em sepse, se a lesão cardíaca é causa das alterações da variabilidade da freqüência cardíaca e sua correlação com a mortalidade. Analisar também a associação entre evolução clínica e variabilidade da freqüência cardíaca, troponina, lesão celular à microscopia eletrônica e óptica e variáveis hemodinâmicas. MÉTODO: Estudo observacional, prospectivo, entre pacientes que desenvolveram sepse grave ou choque séptico, analisando sobrevida. Foram analisados: variabilidade da freqüência cardíca (alta e baixa freqüência, através da monitorização cardíaca contínua), dosagem dos níveis séricos de troponina, creatinofosfoquinase e creatinofosfoquinase fração MB, proteína C-reativa, alterações morfológicas e funcionais das células cardíacas por microscopia óptica e eletrônica e imunoistoquímica. Os dados hemodinâmicos foram obtidos por ecocardiograma e medida direta por cateter de artéria pulmonar. RESULTADOS: Dos 31 pacientes incluídos, 12 (38,7%) morreram durante o acompanhamento de 6 dias e 13 sobreviveram até o 28o dia (41,9%); 6 pacientes (19,4%) morreram nas primeiras 6 horas do estudo. O índice APACHE, utilizado como marcador prognóstico, foi igual nos dois grupos (27 +/- 2,6 nos sobreviventes e 26 +/- 2 nos não sobreviventes). A troponina plasmática se mostrou marcador de disfunção miocárdica na sepse (sobreviventes: 0,53 +/- 0,13 mg/ml, e não-sobreviventes: 2,31 +/- 1,01 mg/ml, p < 0,05), com informação prognostica, e se correlacionou com os piores dados hemodinâmicos do grupo de não-sobreviventes (índice de trabalho sistólico do ventrículo esquerdo no grupo de sobreviventes de 48,1 +/- 6,7 g.m/m2 e no de não-sobreviventes de 34,0 +/- 6,7 g.m/m2, p < 0,05). A variabilidade da freqüência cardíaca diminuída se correlacionou com pior prognóstico e a análise multivariada apontou a baixa freqüência cardíaca como uma variável independente para predizer alta da unidade de terapia intensiva (280 +/- 25 ms2 nos sobreviventes e 84 +/- 7,2 ms2 nos pacientes que evoluiram a óbito, freqüência mínima 129 +/- 19 ms2 e 65 +/- 9 ms2 na freqüência máxima, p < 0,05). A microscopia do coração evidenciou infiltrado inflamatório difuso e aumento do número de mitocôndrias e destruição destas organelas. CONCLUSÃO: Nossos resultados sugerem que a alteração da variabilidade da freqüência cardíaca está relacionada com a evolução para óbito, e correlaciona-se com a lesão cardíaca diagnosticada pela dosagem de troponina sérica e alteração do índice do trabalho sistólico do ventrículo esquerdo por sístole. A histologia do coração demonstrou importante lesão celular do coração, com destruição e aumento do número de mitocôndrias. / CONTEXT: Observational studies have shown alterations in the variability of heart rate in patients with sepsis, although there is not a published study showing correlation to cardiac lesion caused by systemic inflammation and reduction on the heart rate variability. OBJECTIVE: To determine, in patients in sepsis, if the cardiac lesion is caused by the alteration on the heart rate variability and access its correlation with mortality; and also, to analyze the association between clinical evolution and cardiac rate variability, plasmatic troponin, cellular lesion on electronic microscopy and optic and the patients\' hemodynamic data. METHOD: Observational study among patients that developed sepsis or septic shock, analyzing the survivors\' rate. The heart rate variability was analyzed (high and low rate through continuous cardiac monitorization), as well as plasma levels of troponin, CK, CK-MB, C-reactive protein, the morphologic alterations and of cardiac cells function, through electronic and optic microscopy and through immunohistochemistry. The hemodynamics\' data were analyzed though echocardiogram and pulmonary artery catheter. RESULTS: Among 31 patients included, 12 (38.7%) of them died during the course of 6 days and 13 (41.9%) survived until the 28th day, 6 (19.4%) died within the first 6 hours of the study. The APACHE index, used as a prognostic marker, was the same in both groups (27 +/- 2.6 in the survivor group and 26 +/- 2.0 in the non-survivors group). The plasmatic troponin became a marker in the myocardial dysfunction in sepsis (survivors 0.53 +/- 0.13 mg/ml and non-survivors 2.31 +/- 1.01 mg/ml, p < 0.05), with prognostic information, and it correlated with the worst hemodynamic parameters among non-survivors group (left ventricle systolic index was 48.1 +/-6.7 g.m/m2 in survivors and 34.0 +/- 6.7 g.m/m2 in non survivors group, p < 0.05). The decrease on the heart rate variability was correlated with the worst prognoses and analyses pointed to a low rate as an independent variable to predict the patients discharge from the intensive care unit (280 +/- 25 ms2 among survivors and 84 +/-7.2ms2 among non-survivors). The heart microscopy showed diffused inflammatory infiltration and increase in the number of mitochondrias and lesions in these organelles. CONCLUSION: Our results suggest that the alteration of the variability on the heart rate is related with the evolution to death, and correlated to cardiac lesion, evidenced through the dosage of troponin, and to alteration of the systolic workload of the left ventricle by systole. The heart histology demonstrated important cellular lesion of the heart, with a raise in number of and damage to mitochondrias.
160

Avaliação dos fatores de risco de extrassístoles supraventriculares e ventriculares em pacientes ambulatoriais / Evaluation of risk factors of premature atrial and ventricular beats in outpatients

Ribeiro, Wilma Noia 17 May 2018 (has links)
As extrassístoles são achados frequentes em pacientes ambulatoriais, o que suscita o interesse em avaliar o seu significado clínico e fatores associados. O objetivo do estudo foi investigar as variáveis relacionadas com a presença de extrassístoles identificadas em pacientes ambulatoriais selecionados ao terem recebido a indicação de eletrocardiograma de rotina na rede básica de saúde. Foi realizado estudo transversal com 407 pacientes (idade média 55,8 anos ± 12 anos, 56% mulheres) encaminhados de Unidades Básicas de Saúde para o Hospital Municipal Doutor Fernando Mauro Pires da Rocha para realização de eletrocardiograma de repouso. Os participantes foram submetidos a questionário, exame físico, exames laboratoriais, ecocardiograma e monitorização eletrocardiográfica ambulatorial de 24 horas, a qual foi empregada para categorizar a frequência de extrassístoles. Depois de análise descritiva e exploratória, a regressão logística foi utilizada para avaliar as associações entre as variáveis. Extrassístoles supraventriculares ( >= 4/hora) se relacionaram com a idade (razão de chances 1,030; intervalo de confiança 95% 1,002 - 1,059; p=0,029), níveis de peptídeos natriuréticos > 20mg/dL (razão de chances 4,489; intervalo de confiança 95% 1,918 - 10,507; p=0.0005), bloqueios intraventriculares (razão de chances 4,184; intervalo de confiança 95% 1,861 - 9,406; p=0,0005) e diâmetro de átrio esquerdo (razão de chances 1,065; intervalo de confiança 95% 1,001 - 1,134; p=0,046). Extrassístoles ventriculares ( >= 5/hora) se associaram com a idade (razão de chances 1,032; intervalo de confiança 95% 1,010 - 1,054; p=0,004), uso de bloqueadores de canais de cálcio (razão de chances 2,248; intervalo de confiança 95% 1,019 - 4,954; p=0,045), níveis de peptídeos natriuréticos > 20mg/dL (razão de chances 2,079; intervalo de confiança 95% 1,062 - 4,068; p=0,033), taxas de HDL-colesterol (razão de chances 0,971; intervalo de confiança 95% 0,951 - 0,992; p=0,007), frequência cardíaca no eletrocardiograma (razão de chances 1,019; intervalo de confiança 95% 1,001 - 1,038; p=0,041), hipertrofia ventricular esquerda (razão de chances 2,292; intervalo de confiança 95% 1,402 - 3,746; p=0,001) e fração de ejeção ventricular esquerda (razão de chances 0,938; intervalo de confiança 95% 0,900 - 0,978; p=0,002). Na população estudada, os batimentos prematuros foram achados recorrentes e de baixa densidade na eletrocardiografia dinâmica de 24 horas. Extrassístoles mais frequentes se associaram a níveis de peptídeos natriuréticos > 20mg/dL e taxas mais baixas de HDL-colesterol; além disso, foi identificada maior dilatação atrial e hipertrofia ventricular no ecocardiograma dos pacientes com esse achado, sugerindo acometimento de órgão alvo decorrente de hipertensão arterial não controlada. Portanto, a detecção de extrassístoles frequentes na monitorização eletrocardiográfica de 24 horas, em pacientes acompanhados no nível de atenção primária, reitera as recomendações dirigidas principalmente para os cuidados com os fatores de risco associados com a sua presença / Premature complexes are common findings in outpatients; thus, it is important to evaluate their clinical significance and related factors. The aim of our study was to examine the variables associated with premature beats identified in outpatients who were followed by general practitioners in a primary public healthcare setting. We performed a cross-sectional study of 407 outpatients (mean age: 55.8±12 years; 56% women) who were referred from Basic Health Units to Doctor Fernando Mauro Pires da Rocha Municipal Hospital to perform a resting 12-lead electrocardiogram for clinical follow-up. They answered a questionnaire and submitted the physical examination, fasting laboratory testing, transthoracic echocardiogram and 24-hour Holter monitoring, which were used to categorize the frequency of premature complexes. After the univariate analysis, logistic regression analyses were performed to evaluate the independent association among the variables. Premature atrial complexes ( >= 4/hour) were associated with age (odds ratio 1.030; confidence interval 95% 1.002 - 1.059; p=0.029), peptide natriuretic levels > 20mg/dL (odds ratio 4.489; confidence interval 95% 1.918 - 10.507; p=0.0005), intraventricular blocks (odds ratio 4.184; confidence interval 95% 1.861 - 9.406; p=0.0005) and left atrium diameter (odds ratio 1.065; confidence interval 95% 1.001 - 1.134; p=0.046). Premature ventricular complexes ( >= 5/hour) were associated with age (odds ratio 1.032; confidence interval 95% 1.010 - 1.054; p=0.004), the use of calcium channels blockers (odds ratio 2.248; confidence interval 95% 1.019 - 4.954; p=0.045), peptide natriuretic levels > 20mg/dL (odds ratio 2.079; confidence interval 95% 1.062 - 4.068; p=0.033), HDL-cholesterol levels (odds ratio 0.971; confidence interval 95% 0.951 - 0.992; p=0.007), heart rate (odds ratio 1.019; confidence interval 95% 1.001 - 1.038; p=0.041), left ventricle hypertrophy (odds ratio 2.292; confidence interval 95% 1.402 - 3.746; p=0.001) and left ventricle ejection fraction (odds ratio 0.938; confidence interval 95% 0.900 - 0.978; p=0.002). In our population, premature complexes were common findings on 24-hour Holter monitoring, but of low density. Frequent ectopic beats were associated with peptide natriuretic levels > 20mg/dL and lower levels of HDL-cholesterol; left atrial enlargement and ventricular hypertrophy were also identified on the echocardiograms of these patients, suggesting that target organ damage was due to uncontrolled arterial hypertension. Therefore, the identification of frequent premature complexes on 24-hour Holter monitor recording of outpatients in a primary public healthcare setting reaffirms the need for monitoring for the risk factors associated with this finding

Page generated in 0.0562 seconds