• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • Tagged with
  • 10
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

: Funktionell Textil - Fördjupning i textila material med syfte att användas i underställ för vinteraktivitet

STRAND, JENNY, ROOS, ELSA, TURPEINEN, ELIN January 2013 (has links)
För att behålla kroppens fungerande temperatur vid utövande av aktivitet krävs träningskläder i ett material som kan transportera fukten från kroppen och samtidigt minimera ansamlingen av vätska på huden. Utvecklingen av nya material med förbättrade funktioner går ständigt framåt. I denna rapport har olika fibrer jämförts för att kunna komma fram till vilket material samt passform och varukonstruktion som lämpar sig i ett underställ avsett för män vid utövande av medelhög vinteraktivitet. Resultatet skall ligga till grund för en produktutveckling av ett underställ åt företaget Salming Outdoor. Grunden lades genom en utförlig materialinsamling där artiklar och litteratur inom ämnet granskades. En enkätundersökning sändes även ut till önskad målgrupp för att därigenom kunna få primär information om åsikter och efterfrågan kring egenskaper och upplevelse av underställ. För att komma fram till underställets utformning undersöks i rapporten vilka funktioner som efterfrågas i ett underställ, vilka befintliga material och fibrer som har de egenskaper som i en vara ger de funktioner som efterfrågas i ett underställ samt vilken bindning och passform som är mest effektivt i ett underställ för att uppnå önskade funktioner. Efter analys av insamlat material har olika materialsammansättningar diskuterats vilket lett till att ett resultat i form av att en materialmix med syntetfibern polypropylen och naturfibern ull tillsammans skulle vara effektivt för att kunna uppnå framförallt värmande och fuktavvisande egenskaper. Materialet kommer att stickas upp i double jersey med en speciell bindning som stickar polypropylen på insidan i en luftig bindning och ull på utsidan i en slätstickning. / Program: Textil produktutveckling och entreprenörskap
2

TRÄYTTERVÄGGSKONSTRUKTIONER MED DIFFUSSIONSÖPPNA TÄTSKIKT : UTIFRÅN ETT FUKTPERSPEKTIV / TIMBER EXTERIOR WALL CONSTRUCTION WITH DIFFUSION-OPEN SEALING LAYERS : FROM A MOISTER PERSPECTIVE

Werneteg, Christoffer, Storås, Linn January 2022 (has links)
Abstract Introduction: The design of an exterior wall of timber construction where all forms ofplastic can be avoided is not something that is used in today's buildings in Sweden. Thepurpose of the study is to compare two exterior wall constructions where one exteriorwall is used in today's buildings and contains plastic foil. The other wall does notcontain plastic or steam brake.The aim of the report is to compare these two exterior wall constructions from amoisture perspective where the construction without plastic and steam brake is studiedto be able to verify whether it is possible to use this in today's buildings. The questionsto be studied are the following: - What is the basis for the material choices for wooden exterior wall construction? - How do the moisture conditions vary between the selected exterior wall of timberconstructions based on the actual experiment and the theoretical calculations? Method: The study consisted of a combination of qualitative and quantitative methodswhere several collection methods were used such as interviews, experiments andcalculations. The main topic in the study was moisture and with the help of the methodsprimary data were collected, as well as secondary data were collected through themethod literature study. Results: The study showed results how two different exterior wall of timberconstruction vary from each other based on the parameters relative humidity, steamcontent and temperature. The results are reported through tables and diagrams of howthe walls are affected in the worst possible cases regarding moisture surcharge. Analysis: The analysis links the question, the result, and the theoretical frameworktogether. The values presented in the results are linked to the framework wherescientific studies either support or do not support the results that have been producedduring the study. This finally answered the questions that the report was based on. Discussion: This part presents a discussion regarding the results which have beencollected in the study. This section also presents a method discussion containingarguments whether the methods worked or not.
3

Utvärdering av befintliga passivhus : En byggnadsfysikalisk bedömning och mätningar om temperatur, och fukt analys på ytterväggarna

Husseini, Hazhar January 2012 (has links)
Energy price are on the way up to a high level that will not diminish in the future make us to focus more on the sustainable development for a better solution of residential houses. Passive house or low energy housing are one of the solution to make residential more environment friendly, in same time it´s a financial security using less energy, and saving money. The last 10 years in Germany and all around Europe the concept of passive house been developed, and people aim to know more about these concept that leading the market more attractive for passive houses. A passive house is a well designed building highly insulated and air tight with mechanical ventilated system for the whole building envelope that minimizes the use of energy for heating [1]. The housing company Mimer has chosen to invest in low energy consumption in every new housing project.  These future plan projects are decided to use less than 75 kwh per square meter annually in purchased energy [2]. This thesis is about new constructed passive houses, and focuses on the evaluations of the temperature, and moisture condition for attic, external walls and joist. Reason for doing this investigation is to see if passive houses fulfill the building codes regarding moisture, and temperature changes, and to find in early stage suspicious changes that could affect badly on the building envelop. The aim of this study is -         Moisture risk analyses of the attic, external walls and joist -         Studying temperature analysis   With highly insulated walls the risk for moistures extra sensitive than normal building construction.  Also during summer time the comfort inside may be surprised by high indoor temperature and one solution for that could be using sun shading.
4

Bergsmänniskans dilemma : Hållbarhetsstudie av skalplagg

AEJMELAEUS-LINDSTRÖM, FELIX January 2014 (has links)
Vid extrema bergsaktiviteter som klättring och skidåkning ställs stora krav på utrustningen. Den här studien har fokuserat på skalplagg för alpin miljö. Skalplaggens huvuduppgift är att skydda mot vind och fukt samtidigt som de skall transportera fukt från insidan till utsidan. För att kunna designa och utveckla bästa möjliga skalplagg krävs det kunskap om vilken miljö produkten/plagget ska användas i, vem som ska använda det, hur mycket ska plagget användas, i kombination med vilka andra produkter/plagg och vilken kunskap har användaren? Det är också viktigt att förstå vilka materialkrav som ställs på produkten. Det leder till vikten att även förstå materialens egenskaper, vad det minsta, alternativt största mängden av en viss komponent som krävs för att produkten ska leva upp till de ställda kraven. Kunskap om kraven och funktionerna bakom mekanismerna som uppfyller kraven leder till en möjlighet att optimera plaggets funktion och miljöpåverkan. I denna studie har kunskaper inom textilteknik, fysiologi, termodynamik, kemisk dynamik och teknisk byggteknik kombinerats för att härleda och undersöka kraven på maximalt ånggenomsläpplighetsmotstånd beroende på grad av fysisk aktivitet. Resultatet visar tydligt att det maximala ånggenomsläpplighetmotståndet som accepteras vid en given intensitet sjunker med en avtagande temperatur. Detta beror på att fuktgradienten ökar med en avtagande temperatur, under premissen att temperaturen och fukthalten innanför membranet hålls konstant. / Program: Textilingenjörsutbildningen
5

Växthusvävens fukttransmission : Hur struktur och materialval påverkar växthusvävens fuktgenomsläpplighet / The greenhouse screens water vapour transmission : How structure and choice of material affects the screens water vapour permeability

Bernardo, Alexandra, Sund, Linda January 2010 (has links)
Växthus används för att ge ett bättre odlingsklimat åt grödor och växter. För ytterligare förbättring av förhållandena används växthusvävar som exempelvis kan reglera temperatur, fuktighet och ljustillförsel. Väven som behandlas i denna rapport är en så kallad energiväv som främst har till uppgift att minska energiåtgången vid uppvärmning.När väven är fördragen nattetid, ökar luftfuktigheten då grödorna avger fukt dygnet runt. Fukten kan kondenseras mot energiväven, vilket gör att det bildas droppar på väven som kan falla ned på växtligheten. Den höga luftfuktigheten kan medföra svampsjukdomar och i övrigt också bidra till att tillväxten avstannar. Ludvig Svensson AB i Kinna som tillverkar växthusvävar vill undersöka hur struktur och materialval påverkar energivävens fuktgenomsläpplighet. Detta skall göras genom framtagning av ett antal olika provmaterial, där modifieringar av energiväven görs. Provmaterialens fukttransmission mäts med fyra metoder, saltmetoden (EN ISO 15 496:2004), kanadensiska burkmetoden (CAN2-4.2-metod 49:1977), hudmodellen (ISO 11 092:1993 (E)) och Permatran-W som baseras på ASTM E96/E96M-05. De två förstnämnda metoderna utfördes på Swerea IVF AB i Mölndal. Ett antal förändringar gjordes på väven, däribland byte av material, ändring av masklängd och bindningstyp. Resultaten visade att en modifiering av plastsorten i väven gav störst förändring av fuktgenomsläppligheten. De flesta provmaterialen påvisade en mindre fukttransmission än hos den ursprungliga energiväven, dessa värden kan i sig ge användbar data inför framtida produktutveckling. / <p>Greenhouses are used for the improvement of the cultivation climate for crops and plants. For further improvement of the environment, climate screens can be used, they control for example the temperature, humidity and brightness. The screen which is treated in this report is an energy saving screen that lowers the energy consumption.</p><p></p><p>When the greenhouse is covered at night, the humidity increases, since the crops transpire round the clock. The moisture can condense on the cold screen which contributes to the forming of drops that fall down on the vegetation. This effect and the high humidity level in the greenhouse could lead to fungus disease and a decrease in the growth of the cultivation.</p><p></p><p>Ludvig Svensson AB in Kinna who produces different climate screens, would like to investigate how structure and choice of material affects the energy saving screens water vapour transmission. This should be done by modifying the existing climate screen. The modified materials will be tested with four water vapour transmission methods, ISO 15496:2004, the cup method (CAN2-4.2-method 49:1977), the sweating hotplate method (ISO 11092:1993 (E)) and Permatran-W (based on ASTM - E 96/E 96M -05). The first two methods will be executed at Swerea IVF in Mölndal.</p><p></p><p>A few changes were made on the original screen, for example an exchange of materials, a change of looplenght and a change of binding. The results showed that a modification of the plastic band in the screen gave the largest vapour transmission. The most of the modified materials showed a lower humidity transport then the now existing screen. The given results can still offer useful information for future product development.</p><p>Program: Textilingenjörsutbildningen</p>
6

Ytterväggar för nybyggnation av modulhus : Hur påverkar valet av yttervägg installation och kostnader för modulhus

Mohsin, Nooraldeen, Hardi, Bawan January 2017 (has links)
This work aims at identifying and proposing four prefabricated exterior wall elements to a company that will build small prefabricated houses where the house elements are produced in a Micro factory. The four wall elements are as follows: Corner wall units, wall elements with no cut-out for windows and doors, wall elements with cut-out for a window and door and wall elements with cut-out for a door. In this report four different prefabricated outer wall elements have been proposed for small housing project. A comparison study has been made between three different wall solutions (Outer wall solution two has been proposed by the students themselves as well as outer wall solution one and three from two different building suppliers, Isover and Paroc.) to ensure which of these walls fits the best for the four prefabrication element drawings. The main difference between the walls solutions mentioned above is that outer wall solution two has one thick layer of insulation with light beam rails and outer wall solution one and three has massive tree beams in them with separated insulation layers. The advantage of light rails compared to massive rails in outer walls is that the thermal bridges are minimized due to the fact that there are not as much exposed joints in the outer wall with light rails. One more big difference is that the U-value's differ between the three outer-wall solutions. Since the materials are different in the three outer-walls the sound insulation and fire protection characteristics also differ. The sound insulation and fire protection ability depends mainly on the amount of plaster boards and type of insulation in the wall. Outer wall solution two has been chosen for the house project and it will be the head characteristic wall ahead in this report. Outer wall Option Two) was chosen for the project. It was chosen due to following criteria's: low energy needs for active heating, low manufacturing costs, low U-value, low construction weight, good moist resistance, good sound reduction and high fire protection class.
7

Fuktvandring i putsade lättbetong- och tegelfasader : En undersökning om hur fukt vandrar och beter sig mot en putsfasad av två olika material med olika porositeter. / Moisturetransport in aerated concrete- and brickfacades : A study of how moisture behave and transports in a facade of two different materials with different porosities

Hägg, Marcus, Sjölund, Henrik January 2013 (has links)
I dagsläget finns en stor mängd byggnader i Sverige där fasaden består av puts direkt anliggande mot antingen lättbetong eller tegel. Dessa fasader kan skapa problem för brukaren p.g.a. fukttransport via putsen direkt in i konstruktionen. Problemen som kan uppstå som följd av dessa konstruktioner är inte bara estetiska utan kan även påverka inomhusmiljön. Syftet med detta arbete var att undersöka om det gick att med ny teknik visa de resultat som framkommit från erfarenheter från praktiskt arbete samt undersöka hur en renovering påverkar de fasader som består av puts direkt mot lättbetong eller tegel. Arbetet har utförts med hjälp av simuleringsprogrammet Wufi Pro för att sedan analyserats med hänsyn till fukttransporter och vatteninnehåll. Resultaten som framkommit påvisar en förhöjd risk för problem med de ursprungliga fasaderna samt slutsatsen att en renovering enligt ett av de två förslagen är att föredra. / Today there’s a great deal of buildings in Sweden where the facade is constructed by plaster directly connected to either aerated concrete or masonry brick. These facades could create problems for the user on accord of the moisture transport via the plaster directly into the construction. The problems that could follow these types of facades aren’t just esthetical but could also affect the indoor environment. The purpose with this study was to examine if it would be possible using today’s technology to show the results coming from past experiences by practical work, and at the same time examine how a remodel affects the facades that consists of plaster directly on aerated concrete or masonry brick. The work has been conducted with the simulation program Wufi Pro, later to be analyzed  according to moisture transport and water content. The results that came from this has shown an increased risk for problems with the original facades and at the same time that a remodel according to one of the two proposed remodel ways to prefer.
8

Termofysiologisk komfort : En studie där värmeisolering och fukttransportegenskaper undersöks i alternativa materialval än de konventionella för tillämpning i underställ / Thermophysiological comfort

Hollén, Moa, Westerlund, Filippa January 2023 (has links)
Funktionskläder utgör idag en stor marknad över hela världen med stigande efterfrågan där syntetiska material står för en betydande andel av de producerade textilierna. Ett plaggs totala miljöpåverkan kan till stor del härledas till materialvalet. Materialkompositionen i underställ består ofta av blandningar av textila fibrer, vilket komplicerar återvinningsprocessen och gör den nästintill omöjlig. För att kunna 'sluta cirkeln' måste innovativa textila lösningar tas fram för att styra textilindustrin i rätt riktning. Studien undersöker alternativa fibrer och jämför dem med de konventionella för textilier till underställ där man vill uppnå god fukttransport och värmeisolering. Vidare kartläggs materialens användningsområden för att skapa ett mångsidigt funktionsplagg och därmed möjliggöra en klimatsmartare garderob. Studien identifierar och jämför de termofysiologiska egenskaperna hos materialen bambuviskos, merinoull, Tencel, PCM och Coolmax. Textilprover stickades i hundraprocentiga materialkompositioner med en utvald trikåbindning i en rundsticksmaskin. Textilprovets termofysiologiska egenskaper utvärderades med hjälp av testutrustningarna Hudmodellen och WickView för att bestämma värmemotstånd och fukttransport. Därefter analyserades resultaten på materialens termofysiologiska komfort för att sedan kartlägga deras användningsområde baserat på aktivitetsnivå och omgivningsfaktorer. Resultaten från studien indikerar att merinoull och Coolmax kan rekommenderas för användning i underställ där både värmeisolering och fukttransport är viktiga, där merinoull är mest lämplig för kalla klimat. Vidare kan bambuviskos och Tencel vara lämpliga alternativ för användning i underställ vid aktiviteter av måttlig intensitet i varierande klimatförhållanden. PCM, med sitt låga värmemotstånd och medelhöga fukttransport, gör materialet mindre lämpligt för underställ. Testresultaten från studien ger insikt i materialens termofysiologiska komfort, men bör inte ses som en heltäckande bild av denna komfort. För att erhålla en mer valid slutsats krävs ytterligare tester och beaktande av fler faktorer. / Functional clothing represents a significant global market with rising demand today, where synthetic materials account for a considerable proportion of the textiles produced. A garment's total environmental impact can largely be traced back to the choice of material. The material composition of base layers often consists of mixtures of textile fibers, which complicates the recycling process and makes it almost impossible. To 'close the loop', innovative textile solutions must be developed to steer the textile industry in the right direction. The study investigates alternative fibers and compares them with conventional ones for textiles in base layers where effective moisture transport and heat insulation are sought. Furthermore, the areas of use for these materials are mapped out to create a versatile functional garment, thereby enabling a more climate-smart wardrobe. The study identifies and compares the thermophysiological properties of the materials bamboo viscose, merino wool, Tencel, PCM, and Coolmax. Textile samples were knitted in 100% material compositions using a selected tricot stitch on a circular knitting machine. The thermophysiological properties of the textile samples were evaluated using the Skin Model and WickView testing equipment to determine heat resistance and moisture transport. Afterwards, the results on the materials' thermophysiological comfort were analyzed, and their areas of use were mapped out based on activity level and environmental factors. The results from the study indicate that merino wool and Coolmax can be recommended for use in base layers where both heat insulation and moisture transport are important, with merino wool being most suitable for cold climates. Furthermore, bamboo viscose and Tencel could be suitable alternatives for use in base layers for activities of moderate intensity in varying climate conditions. PCM, with its low heat resistance and medium-high moisture transport, makes the material less suitable for base layers. The test results from the study provide insight into the materials' thermophysiological comfort but should not be seen as a comprehensive picture of this comfort. To obtain a more valid conclusion, additional tests and consideration of more factors are required.
9

Fuktrelaterade risker vid lågenergikonstruktion i lättbetong : En studie av ett nyproducerat passivhus / Moisture related risks with aerated concrete in low energy constructions : A study of a newly produced passive house

Jansson, Sebastian, Niklasson, Erik January 2014 (has links)
Trenden i byggbranschen är att efterfrågan på täta, energisnåla byggnader ökar. Passivhus och andra lågenergikonstruktioner blir vanligare och vanligare. Riskerna med att bygga in organiskt material som trä i dessa konstruktioner har fått branschen att börja titta på alternativa material. Lättbetong är ett material som både har bärande och isolerande egenskaper. Dessutom är det inte organiskt vilket gör det okänsligt för mikrobiell påväxt. Det som är intressant med lättbetong, ur fuktsynpunkt, är att materialet levereras från tillverkare med en stor mängd byggfukt. Våren 2014 färdigställde Bollnäs Bostäder passivhus- projektet Sundsbro i Bollnäs, där lättbetong ingår i utfackningsväggarna. Sett inifrån består väggen av ett tunt lager kc-puts, lättbetong, cellplast, mineralull, kc-baserad grovputs och ytputs. I detta arbete användes projektet i Bollnäs som referensobjekt och en risk- och känslighetsanalys av väggkonstruktionen utfördes. Arbetet utreder risken för fuktrelaterade problem med väggen vid de extra uttorkningsinsatser som vidtogs i referensobjektet och vid normala uttorkningsbetingelser. Vidare utreds vilka parametrar som är viktiga för väggens fuktfunktion och vad man behöver tänka på när man projekterar och bygger i lättbetong. Arbetet har genomförts i samarbete med AK-Konsult Indoor Air AB och deras senior konsult Anders Kumlin. Fuktberäkningsprogrammet WUFI Pro 5.3 har använts för simuleringar. Beräkningarna gjordes endimensionellt på väggkonstruktionen. Resultaten med den ökade uttorkning som utfördes i referensobjektet visar inget högre fuktinnehåll längst ut i väggen på grund av byggfukt från lättbetongen som vandrar utåt. Farhågan var att så skulle kunna ske och att det skulle kunna leda till mögelproblem. Däremot visar resultaten att bygg-fukt från putsen kan fukta upp mineralullen. Det finns dock inga kända skadefall av detta slag och därför dras ändå slutsatsen att konstruktionen är riskfri. Tack vare en förutseende fukt-projektering och väl utförd uttorkning eliminerades risken för mögel. Hade inte dessa åtgärder vidtagits så visar resultaten att en liten mängd byggfukt hade kunnat vandra utåt och kondensera i mineralullen under första vintern. Då hade det funnits risk för mikrobiell påväxt. Detta visar att det är av största vikt att utföra en noggrann fuktprojektering vid byggnation av välisolerade hus i allmänhet och i synnerhet när lättbetong används. Lyckligtvis gjordes detta på ett bra sätt i referensprojektet. Känslighetsanalysen visar att isoleringens diffusionstäthet är avgörande för hur stor del av bygg-fukten som kan vandra utåt och därmed hur stor risken för problem blir. Lägre täthet ger större risk och högre täthet reducerar risken. Resultaten visar också att det är viktigt att inte montera täta skikt på insidan för tidigt. Den allmänna rekommendationen från leverantör är att lättbetongen skall torkas till 15 % fuktkvot på 50 millimeters djup innan målning och tapetsering på insida vägg får ske. Studien visar att detta är ett för högt fukttillstånd om det skikt som appliceras på insida vägg är tätt. Lättbetongen bör torkas till 5 % på 50 millimeters djup innan helt täta skikt kan monteras utan mögelrisk. / The trend in the construction industry is that the demand for tight, energy-saving buildings is rising. Passive houses and low energy constructions are becoming more and more common. The risk with using organic material in this type of constructions has made the industry look at alternative materials. Aerated concrete is a material that has both load-bearing and insulating properties. In addition to that it is not organic, which makes it insensitive to microbial growth. What is interesting with aerated concrete, from a moisture point of view, is that the material is delivered from the producer with a large amount of construction moisture. In the spring of 2014, the passive-house project Sundsbro in Bollnäs with aerated concrete in the wall construction, was finished by Bollnäs Bostäder. In this study the project in Bollnäs was used as reference object and a risk- and sensitivity analysis was made. The study examines the risk of moisture related problems with the wall construction during normal dehydration conditions and after the increased dehydration efforts that were taken in the reference project. The study also examines which parameters are important for the moisture function of the wall construction and what you need to think about when you project and build with aerated concrete. The job has been done in cooperation with AK-Konsult Indoor Air AB and their senior consultant Anders Kumlin. The moisture calculation program WUFI Pro 5.3 has been used for simulations. The results with the increased dehydration that was used in the reference project show no increased moisture content in the outer parts of the construction due to construction moisture from the concrete that wanders outwards. The concern was that so could happen and that it would lead to mould problems. However the results show that construction moisture from the exterior plaster can moisten the mineral wool. There are no known damage cases of this sort and therefore the conclusion is that the construction is free of risk. Thanks to a foreseeing moisture projection and a well performed dehydration the risk of mould was eliminated. If these measures would not have been taken, the results show that a small amount of construction moisture could have wandered outwards and condensed inside the mineral wool during the first winter. Then there would have been a risk of microbial growth. This shows that it is very important to carry out a detailed moisture projection when constructing well insulated houses in general and when using aerated concrete in particular. Fortunately this was properly done in the reference project. The sensitivity analysis shows that the diffusion resistance of the insulation decides how much of the construction moisture that can wander outwards and consequently the size of the problem risk. Results also show that it is crucial not to apply sealing layers on the inside of the wall too early. The general recommendation from the supplier is that the aerated concrete should be dried to 15 % moisture ratio on 50 millimeter depth before painting and paper hanging on the interior surface of the wall can be done. The study shows that the concrete still is too damp at that stage if the layer applied on the inside of the wall is impermeable. The concrete should be dried down to 5 % moisture ratio before sealing layers can be applied without mould risk.
10

Den optimala kombinationen : En produktutvecklingsstudie som undersöker fiberkombinationen merinoull och lyocell, konstruerad till en lager-2 produkt / The optimal combination : A product development study investigating the fiber combination of merino wool and lyocell, designated for a layer-2 product

Ekorre, Elina, Järlebratt, Almida January 2023 (has links)
Syftet med studien är att undersöka hur TencelTM och merinoull bäst kombineras i en stickad frottéstruktur ämnad för en lager-2 produkt. Den stickade strukturen har funktionella krav gällande god fukttransport, nötningsbeständighet och antipilling. Funktionskraven kommer att prövas med standardiserade tester. Ytterligare kommer studien undersöka om hållbarheten för lager-2-tyg skulle kunna förbättras. En design research method används för att skapa tre frottéstickade trikåstrukturer, alla med olika kombinationer av lyocell och merinoull. Resultaten visade att alla strukturer hade relativt goda förmåga att transportera fukt, dock stod S-M-T ut som bäst, tätt följt av T-M. Bra nötningsbeständighet utmärktes i M-T och T-M, medan S-M-T presterade sämst. Slutligen visade ett pillingstest ett jämnt resultat mellan alla stickade strukturer, T-M fick dock ett något högre snitt än de andra två. Resultaten i relation till hållbarhet visade att ingen av de stickade strukturerna var ensamt signifikant bättre än de andra. Däremot ger studien ett förslag för framtida forskning när det gäller att samspunna garnet placeras på ena sidan, medan merinoull på den andra. / This study aims to investigate how TencelTM and merino wool are best combined in a knitted terry structure modified for layer-2. The knitted structure has functional requirements, which are in regards to good moisture transport (wicking) capacity, abrasion resistances and anti-pilling. The functional requirements will be tested and with the help of the result the study will further investigate if the sustainability of layer-2 fabric could improve. A design research method is applied to create three terry knitted fabric structures, all with different combinations of lyocell and merino wool. The three fabric structures are then assets for the functional requirements through ISO Standards and AATCC tests. The results showed that all structures had relatively good wicking properties, however S-M-T stood out as the best, closely followed by T-M. Good abrasion resistance was noticeable mostly in M-T and T-M, whereas S-M-T performed worst. Lastly, a pilling test showed an even result between all knitted structures, T-M received however a slightly higher average than the other two. The results in relation to sustainability showed that none of the knitted structures were significantly better than the others alone. However, a suggestion for future research is made in regards to the co-spun yarn being placed on one side, while merino wool on the other.

Page generated in 0.0446 seconds