• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 91
  • 48
  • Tagged with
  • 139
  • 139
  • 100
  • 71
  • 43
  • 37
  • 34
  • 34
  • 31
  • 30
  • 29
  • 28
  • 24
  • 23
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Dynamisk energieffektivisering med hjälp av elektrokroma fönster i ett svenskt klimat : En fallstudie av en simulerad kontorslokal med geografisk variabilitet.

Andersson, Nils, Lindberg, Samuel January 2022 (has links)
Det används stora mängder energi inom kontorslandskap för att reglera inomhusklimatet. Intresset har ökat för energisparande åtgärder både politiskt och privat. För kontorsbyggnader är fönster en stor andel av klimatskärmen vilket har en stor påverkan på värme- och kylvärmeenergin som tillförs in i kontorsbyggnaden. Elektrokroma fönster kan, genom att skicka en spänning till ett av fönstrets skikt, aktivt förändra sina egenskaper för att steglöst begränsa solinstrålning i en byggnad.    Denna fallstudie är framtagen för att undersöka var och hur elektrokroma fönster kan användas för att effektivisera inomhusklimatet, med betoning på kylbehov, i Sverige. Undersökningen gjordes genom att göra flertal simuleringar på en kontorslokal i IDA ICE där lokalen simuleras på olika orter. Orter varieras från norr till söder och från kust till inland. Fönsterfasaden simulerades även i olika väderstreck. Resultaten visar att användning av tekniken sänker inkommande värmeenergi genom fönster med runt 60 procent oavsett på omgivande medeltemperatur. Därför motiveras användandet bäst på sydliga fasader och vid orter nära kust eller stora vatten där solvärmelasten är som störst.
92

ENERGIEFFEKTIVISERING AV INDUSTRIELLA VERKSAMHETER : Värderingar grundade i ekonomiska, miljö- och sociala aspekter för GKN ePowertrain, Köping

Söder Altschul, Joakim, Karlsson, Tomas January 2019 (has links)
To decrease the ecological footprint, humans either have to adjust their lifestyles, or the large scale industries must take corporate social responsibility. This study is based on the well-developed field of energy efficiency in industries by applying technology and organizational-focused proposals. The proposals are based on three different aspects, the economic, the environmental, and the social. These three aspects combined are called the triple bottom line perspective. An original case of the study objects energy balance was determined to develop the conclusions, with the simulation program IDA ICE. The study object was GKN ePowertrain, located in Köping. Energy efficiency cases were simulated in IDA ICE to observe the change in the energy balance. The cases and interviews of the employees were the foundation of the discussion where the improvements were critically reviewed from the triple bottom line perspective. The result shown that the temperature was too high for working conditions, the ventilation system consumes a large quantity of energy, and the internal flow of information is insufficient. In conclusion, GKN ePowertrain would increase their overall value by investing in a cooling system and more efficient heat exchangers for their ventilation system. These investments would notably increase their short term value of environmental sustainability and the social aspect. Furthermore, their economic value would increase in the long term. The cooling system would improve the working environment, and a new ventilation system would increase the heat recovery and decrease the energy consumed, even more than the consumption of the cooling system. Finally, GKN should also be more distinct in their information to the employees in the building regarding energy aims and their working environment, to have a positive gain of value in all the fields.
93

Förbättringsåtgärder vid nybyggnation av småhus för att uppnå kommande energikrav : En simuleringsstudie i IDA ICE

Engelmark, Johanna January 2017 (has links)
EU har ställt höga krav på energianvändning i byggnader genom ett nytt direktiv där respektive medlemsland har fått i uppdrag att ta fram gränsvärden för energianvändning i just sitt land. I Sverige har Boverket fått detta ansvar. I och med det skärpta krav som har föreslagits finns en orolighet i byggbranschen att det kommer att bli svårt att uppfylla det. Tillverkare av småhushar ofta en standardiserad konstruktion som de nu kan behöva ändra på. Syftet med detta examensarbete blev därför att undersöka om en småhustillverkare behöver förändra sin standardkonstruktion, och i så fall vilka förändringar som kan göras, för att uppnå det nya kravet för energianvändning. Genom att studera nuvarande energikrav och Boverkets förslag på nytt krav samt teorier inom byggnadskonstruktion har den teoretiska grunden för examensarbetet lagts. En litteraturstudie har dessutom gjorts över tidigare studier inom området, där framför allt förbättringsåtgärder för att få energisnålare hus har varit till stor hjälp för detta arbete. Studien av en småhustillverkare har genomförts genom att energianvändningen av ett småhus i standardutförande har tagits fram i simuleringsprogrammet IDA ICE. Studerat hus är en trävilla med bergvärme och FTX-ventilation beläget i klimatzon 1. Efter simuleringen har åtta förbättringar i husets konstruktion gjorts med nya simuleringar för att identifiera vilka av dessa förbättringar som är lämpliga att utföra. De mest lämpade förbättringarna har slutligen kombinerats ihop för att uppnå det nya energikravet. Studien visar att nuvarande konstruktion inte uppfyller kommande krav. Utifrån de avgränsningar som har gjorts rekommenderas att följande tre åtgärder vidtas; installation av en värmepump med COP 4 istället för 3, fönster och dörrar med U-värde 0,8 W/(m2*K) istället för 1,2 W/(m2*K) samt ytterväggar med U-värde 0,1 W/(m2*K) istället för 0,137 W/(m2*K). Dessa rekommendationer utgår från att det föreslagna kravet även gäller för klimatzon 1. / The EU has demanded lower energy consumption in buildings through a new directive where each member state has been assigned the task of developing new energy consumption targets for their respective country. In Sweden, Boverket has been assigned this responsibility. There is a concern in the Swedish construction industry that it will be difficult to meet these new requirements. Manufacturers of small houses usually have a standardized design that they now may need to adjust. The purpose of this thesis was therefore to investigate whether a single-family house manufacturer needs to change its standard construction, and if so, what changes could be made to achieve the new requirements for energy usage. By studying current energy requirements and Boverket's proposal for future requirements as well as theories in architectural engineering, the theoretical basis for the thesis has been laid out. A literature study has also been performed of previous studies in the field. Particularly studies of home improvements to get energy-efficient houses have been of great help for this work. A single-family house has been constructed and simulated in the IDA ICE simulation program. The house was made out of wood with a ground source heat pump and FTX ventilation located in climate zone 1. Eight improvements in the house design have been studied with new simulations to identify which of these improvements are appropriate to implement. The most suitable improvements have finally been combined to meet the new energy requirements. The study shows that the current house construction design does not meet future requirements. Based on the delimitations that have been made for this thesis, it is recommended that the following three measures are to be taken; A heat pump with a COP of 4 instead of 3, windows and doors with a U-value of 0.8 W/(m2*K) instead of 1,2 W/(m2*K) and outer walls with a U-value of 0.1 W/(m2*K) instead of 0,137 W/(m2*K). These recommendations are based on the assumption that the proposed new requirements are also applicable for climate zone 1.
94

Hur kan en skola med högre energianvändning än det svenska genomsnittet energieffektiviseras? : Energikartläggning

Andersson, David, Olsson, Philip January 2017 (has links)
Europeiska unionen som helhet är en av de största energianvändarna och har en av världens största utsläpp av växthusgaser. För att minska globala uppvärmningen har mål sats upp för att medeltemperaturen på jorden inte ska öka mer än 2 grader sen förindustrielltid. Närmare 40 % av Sveriges totala energianvändning kommer från bostads- och servicesektorn detta i samband med att 2020-målen närmar sig bidrar till att energieffektiviseringar i byggnader blir allt mer essentiellt. Energikartläggningar är ett verktyg för att bestämma vad som har stört energibesparingspotential innan effektiviseringsåtgärder sker. Examensarbetet inkluderar en energikartläggning av Trödje skola som förvaltas av Gavlefastigheter. Arbetet är utfört med simuleringsverktyget IDA Indoor Climate and Energy. IDA ICE användes för att modulera den befintliga byggnaden där all data för skolan inkluderades. Rapportens vision är att undersöka hur mycket energi som är möjlig att spara genom energibesparingsåtgärder samt vilken åtgärd som är effektivast. Energibesparingspotentialen i skolan är hög, skolan använder 42,6 kWh/m2år mer än genomsnittet för Gavlefastigheters skolor vilket motsvarar 21 %. Resultaten visar att skolans komplexitet samt att påbyggnationen även kallad paviljongen är en stor faktor till att energianvändningen är hög. Skolans energianvändning har en potential att minska med 17 % vilket inte motsvarade det uppsatta 25 % - målet med arbetet. Arbetet visar att störst besparingspotential finns via byte av fönster och värmeväxlare i ventilationssystemet men även att de åtgärder som antas ge störst besparing inte alltid är effektivast. / The European Union as a whole is one of the largest energy users and has one of the world's largest greenhouse gas emissions. To reduce global warming, targets have been set to ensure that the average temperature on the earth does not increase more than 2 degrees since the pre-industrial time. Nearly 40% of Sweden's total energy use comes from the building and services sector which in context with that the 2020 targets approaching contributes to the increased need of higher energy efficiency of buildings. Energy audits is a tool for determining what has the greatest potential for saving energy before efficiency measures occurs. The thesis includes an energy audit of Trödje primary and middle school, administered by Gavlefastigheter. The study was performed using IDA Indoor Climate and Energy simulation tool. IDA ICE was used to modulate the existing building where all data for the school was included. The vision of the thesis is to investigate how much energy which is possible to save through energy saving measures and which action that is most effective. The potential energy saving in the school is high, the school uses 42.6 kWh/m2year more than the average for Gavlefastigheter schools, which corresponds to 21 %. The results show that the complexity of the school and the reconstruction, also called the paviljong, are a major factor in the high energy consumption. The school's energy use has a potential to decrease by 17 %, which did not correspond to the 25 % target set for the work. The work shows that the greatest savings potential exists through the exchange of windows and heat exchangers in the ventilation system, but also that the measures that are assumed to give the greatest savings are not always the most effective.
95

Miljövänlig kyla : En studie för framtagning av verktyg för att underlätta val av olika kylsystem / Environmentally friendly cooling : How to facilitating the choice of cooling systems

Fuentes, Cristopher, Peralta, Christopher January 2016 (has links)
The study compared four different cooling systems and analyzed the competitiveness in those systems regarding electricity consumption, environmental impact and life cycle cost analysis. The assignment was given from the consultant company Ramböll who believed in these systems design as a solution to minimize the energy consumption in cooling systems. The purpose of the study was to facilitate the selection of cooling system by finding a key ratio for profitability in terms of energy consumption. This makes it easier to select one of these systems in project planning. A representative building model was built in the energy simulation program IDA ICE. From these result an energy profile was achieved.   The energy profile was then used in another simulation program called Polysun were detailed system regulations could be made. By programing the controllers to regulate the distribution in an efficient way the energy consumption was minimized and matches the building cooling demand. The simulation was done for one full year and the obtained total energy consumption for each system, it was then used to calculate the operational cost. The life cycle cost analysis is a tool that compare each system costs during its lifetime. A depth analysis was also done regarding the sensitivity of changes in the profitability for the systems, by applying different electrical price and cost of capital.   The study shows that the systems with different borehole storage solutions proves to be effective systems for covering the building cooling demand with a significant lower electricity consumption, compared to the system with a chiller. The different borehole storage systems also contribute to cover some parts of the heat demand, since the stored heat needs to be used in order to make the borehole storage functional. By analyzing the cooling systems in a comparative perspective, the most effective solution is identified from an economic and environmental point of view. The cooling system that only contained a borehole storage was the solution that distinguished the most regarding total electricity consumption and environmental impact. This system resulted in being the most profitable cooling system between the compared systems. The combined system with a borehole storage system and a heat pump solution was also proven to be an effective cooling system, additionally with an advantage of providing parts of the hot water demand in the building.
96

Energibalans och inomhusklimat i ett parkeringshus under jord med behovsstyrd ventilation / Energy balance and indoor climate in a parking garage underground with demand-controlled ventilation

Pohjanen, Alexander January 2017 (has links)
Detta examensarbete är gjort hos VVS-konsulterna Skellefteå AB. Det behandlar projektering av ett parkeringshus med hänsyn till värme och ventilation och en jämförelse av ventilationssystem på ett parkeringshus som är planerad att stå klar 2019. Syftet med arbetet är att undersöka hur man projekterar ett parkeringshus ventilation och om det går att spara energi och utgifter genom att använda sig av behovsstyrd ventilation istället för konstant ventilation. Eftersom det är dyrare att investera i behovsstyrd ventilation kommer det också undersöka återbetalningstiden för den investeringen. För att göra undersökningarna har programmet IDA ICE använts för att rita upp en modell av byggnaden och simulera dess energianvändning för att senare jämföra resultaten och se skillnaderna mellan de olika ventilationssystemen. Ett förslag har framtagits på hur ventilationen kan dras och hur fläktluftvärmare ska installeras och hur rören ska dras. Resultatet från simuleringarna gav den totala energiförbrukningen minskade med 705 000 kWh/ med behovsstyrd ventilation jämfört med konstant ventilation. Fläktens energianvändning minskade med 75% och uppvärmningsenergin minskade med 72%. Investeringen för behovsstyrd ventilation jämfört med konstantflödes ventilation är 600 000 kr dyrare och får utifrån beräkningarna i detta arbete en återbetalningstid på 1 år. Livslängden på ventilationssystemet antas vara 25–30 år. / This graduate work was conducted in cooperation with the VVS-Consultants Skellefteå AB. It deals with the design of a parking garage regarding heat and ventilation and a comparison of ventilation systems in a parking garage that is scheduled to be ready 2019. The purpose of the work is to investigate how to design a parking garage ventilation and if you can save energy and expenses by using demand-controlled ventilation instead of constant ventilation. As it is more expensive to invest in demand- controlled ventilation, it will also investigate the repayment period for that investment. To do the studies, the IDA ICE program has been used to draw a model of the building and simulate its energy use to compare the results later and see the differences between the different ventilation systems. A proposal has been made on how ventilation can be drawn and how the radiators are to be installed and how the pipes are to be drawn. The result of the simulations resulted in total energy consumption decreased by 705,000 kWh / with demand-controlled ventilation compared to constant ventilation. The fan's energy consumption decreased by 75% and the heating energy decreased by 72%. The investment for controlled ventilation compared to constant flow ventilation is 600,000 kr more and, based on the calculations in this work the repayment period is 1 year. The life expectancy of the ventilation system is assumed to be 25-30 years.
97

Energikartläggning av förskola : Underlag för energieffektiviseringsåtgärder av byggnaden Metreven samt fördjupning avseende potential för uppfyllande av Boverkets krav gällande nära- nollenergibyggnad

Lehtonen, Joakim January 2020 (has links)
The Swedish residential sector consumes almost 39 % of Sweden’s final energy consumption. The European Union framework ”Clean Energy for all Europeans package” strives to promote a 32,5 % reduction as a result of energy efficiency measures. The Swedish legislation BBR regulates rules regarding new buildings, extensions and reconstruction of existing buildings. Excerpt 9 regards how energy is being used and determines the demands e.g. for a buildings primary energy use to be classified as a near zero energy building (NZEB). The energy use of a building, located in Västerås, Sweden, is being decided. Various energy efficiency packages are applied to a model in the simulation software IDA ICE. The results are compared with each other deciding the potential benefits of the energy efficiency measures. A substantial decrease of the energy consumption is detected, especially for the energy efficiency packages containing a geothermal heat pump (66 – 78 %). A life cycle cost analysis shows that the package containing a ventilation heat recovery system (FTX) combined with a geothermal heat pump is the optimal solution through an economical point a view. The solution yields a profit after 14 years. The analysis shows that all geothermal solutions, except a system consisting of a geothermal heat pump, FTX, energy efficient windows, rooftop insulation and a photovoltaic system, yields a profit during a 30-year investment period. None of the packages containing a district heat exchanger yield a profit. The simulation results show that by implementing any of the geothermal heat pump packages, the demands for classifying the building according to an NZE building are fulfilled. Regarding the district heating packages, only the package containing all the energy efficiency measures (energy efficient windows, rooftop insulation and PV) meets the demands to be classified as an NZE building. Regarding the environmental impact due to implementing the energy efficiency measures, the results show a reduced impact from applying the geothermal heat pump packages is equivalent to the energy consumption reductions. The results show that by implementing a district heating system, more than one additional energy efficiency measure must be applied to avoid an increased environmental impact. This thesis shows that implementing energy efficiency measures can decrease energy consumption and yield an economical profit to the existing building stock.
98

Simulering och utvärdering av en klimatpositiv byggnads energisystem : Energibedömning och fördelar kring förnybara resurser i ETC Bygg AB:s nollenergibyggnader av flerbostadstyp

Svanbäck, Martina, Lindström, My January 2021 (has links)
Purpose: The purpose with this project was to evaluate the environmental, social, and economic aspects regarding two climate positive buildings in Västerås municipality in Sweden. The company responsible for the buildings, ETC Bygg AB, has assigned this task tothe research group Future Energy Center (FEC) at Mälardalen University. Method: The buildings was simulated with the programs IDA ICE and PVGIS to obtain the overall energy consumption and building efficiency as well as the PV system potential. Regarding transportation, vehicle and driver statistics was studied and adapted to the case study to estimate the tenant’s climate impact. Results: The results showed that the electricity obtained from the PV system both covers the building’s, and tenant’s estimated yearly electricity consumption, but also with a surplus available for storage or selling. The simulatedresults were compared to several previous studies with similar outcome, but with slightly different results. The tenants need for climate friendly transportation resulted in a suggestion of an electric mobility station consisting of electric cars, mopeds, and bicycles to lower the tenants carbon mitigation, costs, and energy consumption. Conclusions: Conclusions from the study was that the buildings meet both the BBR, and the FEBY18 Gold requirements with their high energy efficiency, as well as that the solar power system most likely will produce enough energy to cover both building, and tenant power consumption. A conclusion can be made that the transition to electric transportation have a potential to save both a considerable amount of energy and money for the tenants, but also the possibility to lower their collective yearly carbon mitigation. Also, that the life in a climate positive building have mostly, if not only, positive impacts on its residents.
99

Techno-economic analysis of demand flexibility from heat pumps for multi-family buildings in Sweden based on two case studies

Ko, Hsin-Ting January 2020 (has links)
Sweden is undergoing energy transition to become a zero-carbon economy with electricity production aims at 100% from renewable resources by 2040. Sweden also has a national goal to have fossil-free vehicle fleet by 2030. The increasing share of intermittent renewable resources creates growth in mismatches between electricity supply and demand. Demand flexibility provides solution to imbalances in power system where the prosumers can regulate their energy consumption. Demand response (DR) mechanism could be beneficial to power gird stability. Electric heat pumps serve as a pool of flexible load meanwhile the thermal inertia of the residential buildings serves as thermal energy storage. In this thesis, a techno-economic analysis of demand flexibility from heat pumps for residential buildings located in central Örebro is carried out with assistance of building energy simulations. This thesis aims to improve the intelligence of this existing buildings by comprehending the size of thermal inertia availability according to different heat demand, building envelope materials, ventilation systems, weather conditions and user behaviors. Two multi-family residential buildings, Klockarängsvägen and Pärllöken, are selected for case study and compared in terms of thermal inertia and avoided peak power fees in avoided peak power fee from flexible heat pump loads. Both buildings use heat pumps for space heating and domestic hot water supply. Electricity billings are subscribed to power tariff scheme, which makes peak power shifting more profitable. On the coldest day scenario when the ambient temperature is -20°C, Pärllöken’s indoor temperature drops from 21°C to 19.1°C if heat pump is turned off for an hour. Klockarängsvägen’s indoor temperature drops from 21°C to 16.6°C if heat pump is turned off for an hour. At the lowest indoor temperature setpoint of 18°C, Pärllöken demonstrates a maximum power-shift capacity of 25 kW and heatshift capacity of 75 kWh on the coldest day. That of Klockarängsvägen is a maximum power-shift capacity of 20 kW and heat-shift capacity of 20 kWh. With larger building thermal inertia and more power-shift capacity, Pärllöken is undoubtedly the winner thanks to concrete wall materials, heavier building thermal mass, balanced ventilation, heat recovery system, and higher window class. In economic analysis, based on the proposed energy models, two control strategy options in Pärllöken are considered. Economic analysis focuses on winter season from October to March. Option 1 operates heat pump in variable capacity control mode at part load capacity. Option 2 operates in fixed capacity on/off -4- control. In winter season, Pärllöken saves 1 646 SEK in Option 1 and 2 273 SEK in Option 2. Klockarängsvägen only considers Option 1 for economic analysis, which results in 20 948 SEK avoided peak power fee. Option 2 for Klockarängsvägen exceeds indoor temperature setpoint very quickly mainly due to poorer building envelope insulation in which conserves lower thermal inertia. / Sverige genomgår en energitransformation för att bli en fossilfri ekonomi som siktar på att ha en elproduktion från 100% förnybara resurser år 2040. Sverige har också ett nationellt mål att ha en fossilfri fordonsflotta till 2030. Den ökande andelen av intermittenta förnybara resurser bidrar till ökning av obalans mellan produktion och efterfråga av elektricitet. Efterfrågeflexibilitet ger en lösning på problemet med obalanser i energisystemet där prosumenter kan reglera sin energiförbrukning. Efterfrågeflexibilitet kan vara fördelaktigt för kraft- och nätstabilitet. Elektriska värmepumpar kan agera som en stor flexibel last samtidigt som fastighetens termiska tröghet fungerar som värmeenergilagring. I denna avhandling utförs en teknisk-ekonomisk analys av efterfrågeflexibilitet från värmepumpar för två bostadshus beläget i centrala Örebro med hjälp av energisimuleringar av fastigheten. Genom denna avhandling syftar författaren på att höja intelligensen av de befintliga fastigheterna genom att undersöka storleken av den termiska trögheten som finns tillgänglig med avseende på olika värmescenario, byggnadsmaterial, ventilationssystem, väderförhållanden och användarbeteenden. Två flerfamiljshus, Klockarängsvägen och Pärllöken, väljs för jämförelse med avseende på den termisk tröghet som bidrar mest till efterfrågeflexibiliteten. De två utvalda fastigheterna använder värmepumpar för värme och varmvatten. Båda fastigheterna faktureras enligt effektabonnemang, vilket gör effektutjämning mer lönsamt. I det kallaste scenariot, när omgivningstemperaturen är -20°C, faller Pärllökens inomhustemperatur från 21°C till 19,1°C och Klockarängsvägens inomhustemperatur sjunker till 16,6°C om värmetillförseln stängs av i en timme. Under det lägsta börvärdet för inomhustemperatur på 18°C visar Pärllöken en maximal effektförskjutningskapacitet på 25 kW och för Klockarängsvägen-byggnader 20 kW. Med hänsyn till fastighetens termiska tröghet är Pärllöken utan tvekan vinnaren på grund av betong som väggsmaterial, högre termisk massa, balanserad ventilation, värmeåtervinningssystem och högre energiklass på fönsterglasen. Ovanstående skäl gör att Pärllökens termiska tidskonstant är minst tre gånger längre innan temperaturen når det lägsta börvärdet på 18°C, jämfört med Klockarängsvägen. Detta ger att Pärllöken har en högre förskjutningskapacitet av värme på 75 kWh jämfört med Klockarängsvägens maximala förskjutningskapacitet på 20 kWh. I en ekonomisk analys, baserat på författarens framtagna energimodeller, beaktas två styrstrategier i Pärllöken. Den ekonomiska analysen fokuserar på vintersäsongen från oktober till mars. Alternativ 1 driver värmepumpen med partiell kapacitet enligt reglerbar effekt. Alternativ 2 stänger av värmepumpen helt. Under vintersäsongen sparar Pärllöken 1 646 SEK med Alternativ 1 och 2 273 SEK med Alternativ 2. Klockarängsvägen använder sig endast av Alternativ 1 för en ekonomisk analys, vilket resulterar i en kostnadsbesparing på 20 948 SEK. En förstudie med värmepump i kombination med andra förnybara tekniker så som solceller på Klockarängsvägen genomförs för att undersöka potentialen av energibesparing. Kombinationen ger dock inte en positiv effekt på grund av den låga solinstrålningen under vintertid.
100

Fasta och rörliga solskydd : En fallstudie på två skolor

Ekk, Mustafa, Alsakati, Homam, Matloub, Antouine January 2022 (has links)
Purpose: During the summer, overheating in buildings is becoming more common, but at the same time the passive heat from the sun during the winter can be utilized. This project investigates which solar shading is the best alternative to use in new buildings in Kungsbacka municipality. Method: There are three main aspects that this project focuses on, which are economics, energy and thermal climate. To perform the examination in this project, two rooms in two different schools have been examined with four different solar shading options. The solar shading options are fixed solar shading with a 30 degree inclination, fixed solar shading with 45 degree inclination,  variable sun-controlled solar shading, and variable scheduled solar shading. Results: The results of the study shows that variable sun-controlled solar shading provides the best indoor climate from a thermal aspect, and provides the lowest cooling needs as it reduces the amount of passive energy supplied through the window. Variable solar shading is expensive to purchase, maintain and operate. Fixed solar shading types have a cheaper purchase price and have no operation or maintenance costs. Conclusions: you can say that the choice of solar shading types depends on the conditions one has. Given the results from the case studied in this project,  variable sun-controlled solar shading type is better than fixed solar shading but more costly. / Överhettning i byggnader blir med tiden alltmer vanligt under sommaren, men däremot vill man kunna utnyttjapassiva värmen från solen under vintertiden. Detta problem väcker intresse för vilka solskydd typer som ger bästa solavskärmning under sommaren och släpper in mest solvärme under vinter. I detta arbete undersöks vilka solskydd som skulle vara bäst att användas i nya byggnader i Kungsbacka kommun. Det finns tre huvudaspekter som detta arbete fokuserar på, och dessa är ekonomi, energi och termiskt klimat.För att utföra undersökningen i arbetet har två rum i två olika skolor undersökts med fyra olika solskyddsalternativ. De olika solskydd typer som har undersökts är, fast solskydd med 30 och 45 graders lutning samt rörliga solstyrda och schemalagda solskydd. Datainsamlingen i arbetet bygger mest på krav från beställare och myndigheter samt mätningar från rummen som har undersökts. För att studera de två fallen utfördes simuleringar i IDA-ICE i form av värde tabeller från modeller som har ritats med samma förutsättningar som rummen har. Resultatet av undersökningen visar att rörligt solstyrt solskydd ger bästa inomhusklimat ur termisk aspekt, samt ger lägsta kylbehov eftersom den minskar den tillförda passiva energimängden genom fönstret. Däremot är rörliga solskydd dyra i inköp, underhåll och drift. Men de har ganska lång livslängd som skulle genom tiden spara på energi om man har aktiv kylning i byggnaden. I detta arbete var termisk komfort utgående punkt för valet av solskydd då aktiv kylning saknades i både skolorna. Fasta solskydd typer är billigare i inköpspriset och har ingen drift eller underhållskostnader, men det visade sig att de inte är lika effektiva som rörliga solskydd typer när det gäller termisk komfort under sommaren. Valet av solskydd beror helt på vad man är intresserad av och ifall man har aktiv kylning eller inte. När det gäller transmissionsförluster genom fönstren vid användning av olika solskydd typer så visade det sig att det blev nästan samma förluster oavsett vilken solskydd typ som används. Det beror helt på själva fönstrets egenskaper som i både fallen var bra. Slutligen kan man säga att valet av solskydd typer beror på förutsättningarna man har. Resultaten från fallet som studerades i detta arbete är att rörliga solskydds typer är bättre än fast solskydd men dyrare. Det finns dock en kostnadsskillnad när det gäller kylning över längre perioder.

Page generated in 0.0325 seconds