• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • 2
  • 2
  • Tagged with
  • 42
  • 42
  • 26
  • 21
  • 14
  • 10
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Efeitos do vasoconstritor em procedimentos dentais de restaurações e extrações em IC: resultados de um estudo prospectivo, randomizado, duplo-cego (Teeth-HF Study) / Effects of vasoconstrictor on dental procedures in heart failure: Results of a prospective , randomized double-blind study (Teeth-HF study)

Sergio Eduardo Tricta Quaresma 06 November 2018 (has links)
Fundamento: O número de pacientes acometidos por insuficiência cardíaca (IC) cresce anualmente, em razão direta do aumento da longevidade, fato que ocorre mundialmente. Patologias bucais como perda do elemento dental e periodontopatias têm sido relacionadas e apresentam alta prevalência em pacientes com IC. Estes indivíduos necessitam de atendimento odontológico. O uso de solução anestésica local com vasoconstritor para procedimentos odontológicos para esta população continua controverso, pois pode gerar riscos cardiovasculares adversos. Objetivo: Analisar dor e alterações hemodinâmicas em pacientes com insuficiência cardíaca, submetidos a procedimento odontológico sob anestesia local com ou sem epinefrina . Método: Estudo prospectivo, grupo paralelo, controlado, duplo-cego em pacientes com insuficiência cardíaca, fração de ejeção < 45%, classe funcional II e III/IV e com terapêutica otimizada foram randomizados para procedimentos odontológicos (restaurações ou extrações) usando de 1,8ml a 3,6ml solução anestésica de lidocaína a 2% sem epinefrina (LSE) ou a mesma dose de lidocaína com epinefrina 1:100.000 (LCE). Resultados: Setenta e dois pacientes (50 anos ± 10 anos, 62% do sexo masculino, portadores de IC foram alocados para LSE (n=36) ou LCE (n=36). Foram observadas diferenças significativas no desfecho primário (dor) para os grupos que receberam LSE e efetuaram extrações dentárias. Não foram observadas diferenças nos valores de pressão arterial e frequência cardíaca antes, durante e após o procedimento dental em ambos os grupos. Entretanto, quando os grupos foram analisados separadamente, a pressão arterial aumentou e a frequência cardíaca reduziuse significativamente em relação à fase basal, durante o procedimento. Conclusão: A solução anestésica local de lidocaína com epinefrina mostrou ser superior no controle da dor e segura para pacientes com insuficiência cardíaca. Tanto no grupo LSE como no LCE não ocorreram alterações significativas nos parâmetros hemodinâmicos / Background: The number of patients with heart failure (HF) increases annually over the world. Oral diseases have been related to, and have shown high prevalence among this population. These patients need dental care. Using local anesthesia with vasoconstrictor for dental treatments is still controversial in patients with HF because it may generate adverse cardiovascular effects. Goal: To analyze pain and hemodynamic changes in patients with heart failure submitted to a dental procedure under local anesthesia with or without epinephrine. Methods: Prospective, parallel group, controlled, double-blind study , with heart failure patients, ejection fraction < 45%, NYHA class II and III / IV and with optimized therapy, were randomized to dental procedures (dental extraction or restoration) using 1,8 to 3.6ml of lidocaine without epinephrine (LSE) or lidocaine with epinephrine (LCE). ( Lidocaine 2% epinephrine 1:100.000). Results: Seventy two patients (50 ± 10 years, 62% male, 27% ischemic) were allocated to LSE (n = 36) or LCE (n = 36). It was observed a significant increase in pain , among patients that had dental extractions in the LSE group in comparison to LCE. No differences were observed in blood pressure, heart rate and pain scores before, during and after dental procedures in both groups. However, blood pressure increased and heart rate significantly reduced in relation to the baseline phase during and after the procedure in both groups when they were analyzed separately. Conclusion: Lidocaine with epinephrine (LCE) has shown to be more effective for pain control in heart failure patients. Concerning hymodinamic changes there was no difference between groups with or without epinephrine, and the treatment did not cause undesirable adverse cardiovascular effects.
32

Cirurgia da fibrilação atrial crônica com ultrassom em pacientes com lesão valvar mitral.

Brick, Alexandre Visconti 06 May 2016 (has links)
Submitted by Fabíola Silva (fabiola.silva@famerp.br) on 2017-08-09T13:04:41Z No. of bitstreams: 1 alexandrevbrick_tese.pdf: 2077531 bytes, checksum: 63dcd34fc3468a693198938254751cdd (MD5) / Made available in DSpace on 2017-08-09T13:04:41Z (GMT). No. of bitstreams: 1 alexandrevbrick_tese.pdf: 2077531 bytes, checksum: 63dcd34fc3468a693198938254751cdd (MD5) Previous issue date: 2016-05-06 / Introduction: Atrial fibrillation (AF) is the most common arrhythmia with high morbidity and mortality rates. The use of catheter ablation for treatment of AF has stimulated the use of energy sources such as ultrasound (US) in surgery to cause injuries in endocardial way, epicardial way or both, replacing the section and suture of the atrial wall. The presence of previous heart disease, most often injury of the mitral valve in patients with chronic atrial fibrillation (CAF) justifies the surgical treatment of this arrhythmia concomitant to the valve surgery. Objective: To evaluate surgical treatment of CAF with US in patients with mitral valve disease, considering: 1- Preoperative clinical characteristics of patients undergoing surgical treatment of CAF and 2- Follow up of patients in the immediate postoperative period, in hospital and later high up to 60 months. Patients and Method: We retrospectively and consecutively studied 100 patients with CAF and mitral valve disease who underwent surgical treatment using US ablation, aged between 18 and 70 years (43.56 ± 4,94 anos), 63 (63%) were female and 37 (37%) were male. Patient data were reviewed prospectively by consulting the control reports, including demographic variables (gender and age) and heart [signs and symptoms, underlying disease, functional class, hospital stay, surgical procedure time, ablation time, intraoperative and postoperative (immediately discharged and later up to 60 months)]. It was used the actuarial curve (Kaplan-Meier) for the study of permanence without recurrence after 12, 24, 36, 48 and 60 months in patients with CAF. Results: From the patients studied, 86% had rheumatic mitral valve disease, 14% degeneration of the mitral valve, 40% were patients with mitral regurgitation, 19% of mitral lesion, 36% of mitral stenosis and 5% of mitral restenosis. The main symptoms included palpitations related to tachycardia by CAF (70%), congestive heart failure (70%), previous episodes of acute pulmonary edema (27%), stroke by thromboembolism accident (13%) and peripheral embolism (7%). The functional class of patients was III/IV. The early results showed that 94% of patients undergoing ablation US reversed the rate of CAF, being 86% in sinus rhythm and 8% in atrioventricular block, which was transient. At hospital discharge was observed maintenance of sinus rhythm in 86% of patients and recurrence of CAF in 8%. At follow-up after 60 months 83.8% of patients maintained the sinus rhythm. Conclusions: Patients with rheumatic mitral valve disease often have failure and mitral stenosis, palpitations related to tachycardia by CAF and congestive heart failure. Surgical treatment of CAF with US concomitant to the mitral valve surgery is feasible and satisfactory, with maintenance of sinus rhythm in most patients (83.8%) after 60 months of follow-up. / Introdução: A fibrilação atrial (FA) é a mais frequente arritmia com taxa elevada de morbimortalidade. A utilização de ablação por cateter para tratamento de FA estimulou o uso de fontes de energia como ultrassom (US) em procedimento cirúrgico para provocar lesões por vias endocárdica, epicárdica ou ambas, em substituição à secção e sutura da parede atrial. A presença de cardiopatia prévia, na maioria das vezes, lesão da valva mitral, em pacientes com fibrilação atrial crônica (FAC), justifica o tratamento cirúrgico dessa arritmia concomitante à cirurgia valvar. Objetivo: Avaliar tratamento cirúrgico da FAC com US em pacientes com lesão valvar mitral, considerandose: 1- caracterização clínica pré-operatória de pacientes submetidos a tratamento cirúrgico da fibrilação atrial crônica e, 2- acompanhamento de pacientes no pós-operatório imediato, na alta hospitalar e tardio até 60 meses. Casuística e Método: Foram estudados retrospectivamente e de forma consecutiva 100 pacientes portadores de FAC e lesão valvar mitral submetidos a tratamento cirúrgico por meio de ablação com US, com idade entre 18 e 70 anos (43,56 ± 4,94 anos), sendo 63 (63%) do sexo feminino e 37 (37%) do masculino. Dados dos pacientes foram revisados prospectivamente por meio de consulta a fichas de controle, incluindo variáveis demográficas (sexo e idade) e cardíacas [sinais e sintomas, doença de base, classe funcional, tempo de permanência hospitalar, tempo de procedimento cirúrgico, tempo de ablação, complicações intra e pós-operatórias (imediato, alta hospitalar e tardio até 60 meses)]. Foi utilizada a curva atuarial (Kaplan-Meier) para estudo da permanência sem recidiva após 12, 24, 36, 48 e até 60 meses em pacientes com FAC. Resultados: Dos pacientes estudados, 86% tinham doença mitral reumática, 14% degeneração da valva mitral, 40% eram portadores de insuficiência mitral, 19% de dupla lesão mitral, 36% de estenose mitral e 5% de reestenose mitral. Os principais sintomas incluíram palpitações relacionadas à taquicardia pela FAC (70%), insuficiência cardíaca congestiva (70%), episódio prévio de edema agudo de pulmão (27%), acidente vascular encefálico por tromboembolismo (13%) e embolia periférica (7%). A classe funcional dos pacientes foi III/IV. Os resultados imediatos mostraram que 94% dos pacientes submetidos à ablação com US reverteram o ritmo de FAC, sendo 86% em ritmo sinusal e 8% em bloqueio atrioventricular, que foi transitório. Na alta hospitalar observou-se manutenção do ritmo sinusal em 86 pacientes e recidiva da FAC em 8. No acompanhamento, após 60 meses, 83,8% dos pacientes mantinham o ritmo sinusal. Conclusões: Pacientes com doença mitral reumática apresentam frequentemente insuficiência e estenose mitral, palpitações relacionadas à taquicardia pela fibrilação atrial crônica e insuficiência cardíaca congestiva. O tratamento cirúrgico da FAC com US concomitante a cirurgia valvar mitral é factível e satisfatório, com manutenção do ritmo sinusal na maioria dos pacientes (83,8%), após 60 meses de seguimento.
33

Efeito do treinamento físico em portadores de marcapasso definitivo / Physical training effect in pacemaker patients

Emanoel Gledeston Dantas Licarião 16 September 2016 (has links)
Inúmeros problemas cotidianos estão mal esclarecidos para portadores de marcapasso cardíaco definitivo (MCD). Dentre eles, destaca-se sua relação com atividades físicas e programas de treinamento. Este estudo, PRACTICING - Physical Training Effect In Pacemaker Patients, tem o objetivo de avaliar o impacto do treinamento físico sobre o consumo de oxigênio (VO2 pico) e a qualidade de vida em portadores de MCD. Métodos - estudo prospectivo, unicêntrico e randomizado que incluiu portadores de MCD atrioventricular com funções sinusal e ventricular normais, sedentários, com idade entre 18 e 80 anos. Os pacientes foram distribuídos em três grupos: GTFS - grupo treinamento físico supervisionado; GTFNS - treinamento físico não supervisionado e GC - controle. Foram analisadas as variáveis obtidas por teste ergoespirométrico (TEE) e questionários de qualidade de vida (SF36 e Aquarel), no inicio do estudo e após 4 meses de seguimento. Resultados - Foram incluídos 18 pacientes no GTFS; 20 no GTFNS e 20 no GC. A idade média foi 55,4 ± 10 anos, 69,0% era do sexo feminino e a FEVE média foi 63,41 ± 5,0%. Hipertensão arterial, diabetes mellitus e doença de Chagas estiveram presentes em 56,9%, 25,8% e 25,9%, respectivamente. O tempo médio de uso de MCD foi de 59,4 ± 62,6 meses. O VO2máx médio inicial da população foi de 24,0 ± 5,8ml/kg/min e não houve diferença entre os três grupos (P=0,279). Apenas no GTFS ocorreu melhora significativa no VO2máx após treinamento físico: 23,86±4,38 versus 26,74 ± 4,18 ml/kg/min, (P=0,001). A avaliação da qualidade de vida demonstrou apenas diferença no domínio desconforto no peito no GTFNS e dispneia no GC (Aquarell). Conclusão - Em portadores de MCD sem disfunção ventricular, o treinamento físico supervisionado proporcionou melhora expressiva do consumo de oxigênio e de suas repercussões funcionais, embora com baixo impacto na qualidade de vida / Many everyday problems are poorly cleared for permanent cardiac pacemaker (MCD). Among these, there is its relation to physical activities and training programs. This study, PRACTICING- Physical Training Effect In Pacemaker Patients - aimed to assess the impact of physical training on the oxygen uptake (VO2 peak) and the quality of life in patients with MCD. Methods - prospective, singlecenter, randomized trial that included patients with atrioventricular MCD with sinus function and ventricular normal, sedentary, aged between 18 and 80 years. Patients were divided into three groups: GTFS - group supervised physical training; GTFNS - physical training unsupervised and GC - control. We analyzed the variables obtained by cardiopulmonary exercise test form (TEE) and quality of life questionnaires (SF36 and Aquarel) at study start and after four months of follow-up. Results - We included 18 patients in GTFS; 20 in GTFNS and 20 in the control group. The mean age was 55.4 ± 10 years, 69.0% were female and the mean LVEF was 63.41 ± 5.0%. hypertension, diabetes mellitus and Chagas disease were present in 56.9%, 25.8% and 25.9%, respectively. The average time of use of MCD was 59.4 ± 62.6 months. The initial average VO2max of the population was 24.0 ± 5,8 ml/kg/min and there was no difference among the three groups (P = 0.279). Only in GTFS was significant improvement in VO2max after physical training: 23.86 ± 4.38 versus 26.74 ± 4,18 ml/kg/min (P = 0.001). The evaluation of quality of life, demonstrated only difference in discomfort in the chest area in GTFNS and dyspnoea in CG (Aquarell). Conclusion - In patients with MCD without ventricular dysfunction, physical training protocol supervised provided significant improvement in oxygen uptake and its functional repercussions, albeit with low impact on quality of life
34

Quantificação do mapa T1 e do volume extracelular miocárdico por ressonância magnética em pacientes com miocardiopatia não compactada / Myocardial T1 mapping and extracellular volume quantification in patients with non-compaction cardiomyopathy

José de Arimateia Batista Araujo Filho 30 October 2017 (has links)
Introdução: Dos mecanismos fisiopatológicos à estratificação de risco e manejo, ainda persistem hoje muitas lacunas e debates sobre a miocardiopatia não compactada (MNC). Recentemente, a ressonância magnética cardiovascular (RMC) vem sendo amplamente utilizada para aumentar a precisão do diagnóstico de MNC em pacientes com alta probabilidade clínica pré-teste, com valor prognóstico e alta relevância na tomada de decisões clínicas. Objetivo: Este estudo teve como objetivo caracterizar o mapeamento T1 e o volume extracelular (VEC) miocárdico por RMC em pacientes com MNC e investigar como esses marcadores teciduais relacionam-se com a fração de ejeção do ventrículo esquerdo (FEVE) e arritmias ventriculares (AV). Métodos: Foram recrutados prospectivamente 36 pacientes com MNC e 18 controles saudáveis para realizarem uma RMC com mapeamento T1 entre julho de 2013 e setembro de 2016. O VEC foi avaliado apenas para os segmentos do ventrículo esquerdo sem áreas de fibrose macroscópica pela técnica do realce tardio (RT), objetivando-se investigar a presença de fibrose miocárdica intersticial difusa. Para avaliar as diferenças entre os parâmetros de RMC nos pacientes e controles, foram usados o teste t entre as amostras pareadas (Wilcoxon) e um modelo de regressão linear foi construído para investigar a relação entre a FEVE e os achados clínicos e de imagem (inclusive o VEC). Resultados: Os pacientes com MNC apresentaram maiores valores de T1 nativo (1.024 ± 43ms versus 995 ± 22ms, p = 0,01) e VEC (28,0 ± 4,5% vs. 23,5 ± 2,2%, p < 0,001) em relação aos controles. Apenas o VEC foi associado independentemente com a FEVE (beta = -1,3, p = 0,003) na regressão multivariada. Houve uma interessante tendência para a terapia betabloqueadora modificar positivamente a relação entre ECV e LVEF (beta = 4,1, intervalo de confiança de 95%, -0,6 a 8,8), porém com p alto (0,08). Além disso, entre pacientes com MNC e RT ausente (negativo), AV foram associadas com maior VEC (27,7% em pacientes com AV vs 25,8% em pacientes sem AV, p = 0,002). Conclusão: Nos pacientes com MNC, a caracterização tecidual miocárdica por mapeamento T1 sugere uma expansão extracelular por fibrose intersticial difusa no miocardio sem fibrose focal pelo RT, o que foi associada à disfunção ventricular e AV. Tais achados podem dar suporte a um potencial valor do mapeamento T1 no refino da estratificação de risco de pacientes com MNC / Background: From pathophysiological mechanisms to risk stratification and management, much debate and discussion persist regarding non-compaction cardiomyopathy (NCC). Recently, cardiovascular magnetic resonance (CMR) imaging has been widely used to more accurately diagnose NCC in patients with high clinical pre-test probability, with prognostic value and high relevance in the clinical decision making process. Purpose: This study aimed to characterize myocardial T1 mapping and extracellular volume (ECV) fraction by cardiovascular magnetic resonance (CMR), as well as investigate how these tissue markers relate to left ventricular ejection fraction (LVEF) and ventricular arrhythmias (VA) in patients with NCC. Methods: We prospectively recruited 36 patients with NCC and 18 controls to perform a cardiovascular magnetic resonance (CMR) with T1 mapping between July 2013 and September 2016. ECV was quantified in LV segments without late gadolinium enhancement (LGE) areas to investigate diffuse myocardial fibrosis. Differences in CMR parameters between patients and controls were assessed using t-test or Wilcoxon rank-sum test, and a linear regression model was built for LVEF to test the association with ECV and clinical characteristics. Results: Patients with NCC had higher native T1 (1024±43ms vs. 995±22ms, p=0.01) and expanded ECV (28.0±4.5% vs. 23.5±2.2%, p < 0.001) compared to controls. ECV was independently associated with LVEF (beta=-1.3, p=0.003). There was a trend for beta-blocker therapy to modify the relationship between ECV and LVEF (beta=4.1, 95% confidence interval, 0.6 to 8.8, p=0.08). Moreover, among patients without LGE, VA were associated with higher ECV (27.7% with VA vs 25.8% without VA, p=0.002). Conclusion: In NCC patients, tissue characterization by T1 mapping suggests an extracellular expansion by diffuse fibrosis in myocardium without LGE, which was associated with myocardial dysfunction and VA. These findings lend support to the potential role of T1 mapping in refining NCC risk stratification
35

O geraniol reduz a contratilidade e bloqueia canais iônicos no coração de mamífero / Geraniol reduces the contractility and blocks ion channels in mammalian heart

Menezes Filho, José Evaldo Rodrigues de 26 March 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The geraniol (C10H18O) is an acyclic monoterpene alcohol, present in the essential oil of some medicinal plants, herbs and citrus fruits, especially species of the genus Cymbopogon. Were described biochemical and pharmacological properties such as anticonvulsant action, analgesic, antinflammatory, antioxidant, anticancer and antimicrobial activities. In this study we sought to characterize the effects produced by geraniol on contractility, electrical activity and its possible antiarrhythmic potential in mammalian heart. For this, we used guinea-pig (Cavia porcellus) and mice (Mus musculus) of C57Bl/6J strain. The contractile studies were performed in the left atria drawn 1GF and stimulated with pulses of suprathreshold current, maintained in Cuba for isolated organ submerged in modified Tyrode solution (8 mL) and aerated with carbogenic mixture (95% O2 and 5% CO2). The force of atrial contraction was recorded by an isometric transducer. Electrocardiographic recordings were performed on isolated heart under constant aortic perfusion flow (8 mL/min) in a Langendorff system. To study the effects of geraniol on current membrane, experiments were performed using the technique of patch-clamp in rat ventricular cardiomyocytes setup whole-cell. In the atrium, geraniol reduced the force of contraction (~ 98%, EC50 = 1510 ± 160 M) whereas nifedipine, used as positive control, showed a EC50 of 0.90 ± 0.66 M. Geraniol, at 3 mM, decreased the positive inotropism of both CaCl2 and BAY K8644. In ventricular cardiomyocytes, the ICa,L was reduced by 50.7% (n = 5, p < 0.0001) after perfusion with 300 M of geraniol. Furthermore, geraniol prolonged the action potential duration (APD) measured at 50% of repolarization (49.7%, n = 5, p < 0.05), without changing the resting potential. The increase in APD can be attributed to blockade of K+ channel transient outward (Ito) (59.7%, n = 4, p < 0.001), the K+ current non-inactivated (Iss) (39.2 %, n = 4, p < 0.05) and K+ current to inward rectifier (Ik1) (33.7%, n = 4, p < 0.0001). In isolated heart, geraniol increased PRi and QTi without affecting the QRS (n = 6) complex, and reduced both left ventricular pressure (83%) and heart rate (16.5%). Furthermore, geraniol delayed time for the start of ouabain-induced arrhythmias in 128%, preventing in 30% the increase of diastolic tension, however, without affect the positive inotropic effect induced by ouabain (n = 6). Geraniol exerts negative inotropic and chronotropic responses in the mammalian heart by decreasing the L-type Ca2+ current and prolongs the duration of ventricular action potential by reducing potassium currents voltage-dependent. Such effects may be responsible for the antiarrhythmic effect of geraniol front the arrhythmias induced by ouabain in vitro. / O geraniol (C10H18O) é um monoterpeno alcoólico acíclico, presente no óleo essencial de algumas plantas medicinais, frutas cítricas e ervas aromáticas, principalmente espécies do gênero Cymbopogon. São descritas propriedades bioquímicas e farmacológicas, tais como ação anticonvulsivante, analgésica, anti-inflamatória, antioxidante, anticancerígena e antimicrobiana. Neste trabalho buscou-se caracterizar os efeitos produzidos pelo geraniol sobre a contratilidade, atividade elétrica e seu possível potencial antiarrítmico em coração de mamífero. Para tanto, foram utilizados cobaia (Cavia porcellus) e camundongos (Mus musculus) da linhagem C57Bl/6J. Os estudos contráteis foram realizados em átrio esquerdo estirado a 1gf e estimulados com pulsos de corrente supralimiares, mantido em cuba para órgão isolado, submerso em solução de Tyrode modificada (8 mL) e aerado com mistura carbogênica (95 % O2 e 5 % CO2). A força de contração atrial foi captada por um transdutor isométrico. Os registros eletrocardiográficos foram realizados em coração isolado, sob perfusão aórtica de fluxo constante (8 mL/min), em sistema de Langendorff. Para estudar os efeitos do geraniol sobre as correntes de membrana, foram executados experimentos através da técnica de patch-clamp , na configuração whole-cell , em cardiomiócitos ventriculares de camundongo. No átrio, o geraniol reduziu a força de contração (~ 98%, EC50 = 1510 ± 160 M) enquanto que a nifedipina, usada como controle positivo, apresentou uma EC50 de 0,90 ± 0,66 M. O geraniol, na concentração de 3 mM, diminuiu o inotropismo positivo de ambos CaCl2 e BAY K8644. Em cardiomiócito ventricular, a ICa,L foi reduzida em 50,7% (n = 5, p < 0,0001), após a perfusão com 300 μM de geraniol. Além disso, o geraniol prolongou a duração do potencial de ação (DPA), medida a 50 % da repolarização (49,7%, n = 5, p < 0,05), sem alterar o potencial de repouso. O aumento da DPA pode ser atribuído ao bloqueio dos canais para K+ transient-outward (Ito) (59,7 %, n = 4, p < 0,001), canal de K+ não-inativado (Iss) (39,2 %, n = 4, p < 0,05) e do canal para K+ inward rectifier (IK1) (33,7% , n = 4, p < 0,0001). Em coração isolado (n = 6), o geraniol aumentou o PRi e QTi sem afetar a duração do complexo QRS, reduzindo a pressão ventricular esquerda (83%) e a frequência cardíaca (16,5%). Além disso, o geraniol retardou o tempo para o início das arritmias induzidas por ouabaína em 128%, evitando em 30% o aumento da tensão diastólica sem, contudo, afetar o efeito inotrópico positivo da ouabaína (n = 6). O geraniol exerce respostas inotrópicas e cronotrópicas negativas no coração de mamífero, por meio da diminuição das correntes para Ca2+ tipo-L e, prolonga a duração do potencial de ação ventricular por reduzir as correntes para K+ dependentes de voltagem. Tais efeitos podem ser responsáveis pelo efeito antiarrítmico do geraniol frente às arritmias induzidas por ouabaína in vitro .
36

Avaliação dos eventos arrítmicos em candidatos a transplante renal pela monitorização cardíaca com looper implantável / Long-term recording of arrhythmic events with implantable cardiac monitor in renal transplant candidates

Rodrigo Tavares Silva 22 August 2011 (has links)
INTRODUÇÃO: pacientes com doença renal crônica em diálise apresentam elevada mortalidade anual, principalmente decorrente de eventos cardiovasculares, com destaque para morte súbita cardíaca (MSC). Os eventos arrítmicos (EA) são considerados os principais responsáveis pela MSC, tornando relevante a sua avaliação. Dispositivos cardíacos modernos como o looper implantável, que tem capacidade de monitorar o ritmo cardíaco por longo período de tempo e diagnosticar EA, podem contribuir na estratificação de risco desta população. OBJETIVOS: avaliar a taxa de ocorrência dos EA em candidatos a transplante renal com looper implantável e identificar fatores associados; determinar a significância prognóstica dos EA na MSC e mortalidade total; avaliar eficiência diagnóstica do looper e o papel da diálise. MÉTODOS: estudo clínico observacional, prospectivo e aberto que incluiu cem candidatos a transplante renal, em hemodiálise e com alto risco para transplante (idade >=50 anos, DM ou doença cardiovascular). Entre junho/2009 e janeiro/2010, os pacientes foram submetidos ao implante do looper para detecção dos EA e seguimento clínico de um ano. A idade média do grupo foi 59 anos; 65% homens; 97% hipertensos, 70% diabéticos, 34% com infarto prévio e tempo médio de 53,8 meses em hemodiálise. O diagnóstico dos EA seguiu protocolo específico e foram descritos todos os eventos clínicos fatais e não fatais. A estatística incluiu: análise descritiva dos EA, associação destes com variáveis exploratórias pelos testes de qui-quadrado, exato de Fischer, t-Student, Mann-Whitney e regressão logística stepwise selection para análise multivariada (p<0,05). RESULTADOS: foram diagnosticados 5075 EA em 98 pacientes em seguimento médio de 425 dias. A taxa de ocorrência dos EA na casuística foi: bradiarritmias (25%), arritmias supraventriculares (94%) e arritmias ventriculares (79%). Os EA mais comuns foram: taquicardia sinusal (39%) e atrial não sustentada (27%), extrassístoles ventriculares e atriais isoladas (16% e 5,4%) e taquicardia ventricular não sustentada (TVNS - 5,3%). Foram preditores para ocorrência dos EA: duração intervalo PR (p=0,0008; OR=1,05; IC-95%=1,02-1,08) e QT longo (p=0,002; OR=7,28; IC- 95%=2,01-26,35) para bradiarritmias; duração intervalo QTc (p=0,022; OR=1,02; IC-95%=1,01-1,04) e presença de insuficiência cardíaca (p=0,034; OR=9,87; IC- 95%=1,17-82,79) para arritmias ventriculares e dilatação ventricular esquerda (p=0,041; OR=2,83; IC-95%=1,01-7,96) para TVNS. Ocorreram 35 eventos clínicos não fatais, 14 transplantes renais e 18 óbitos. Dentre os óbitos, 38,9% foram cardiovasculares súbitos: quatro arritmogênicos, um IAM e dois indeterminados. Não houve associação entre EA e eventos fatais; fibrilação atrial e bradiarritmias tiveram associação significativa com eventos não fatais. O mecanismo de morte (arritmogênico) foi elucidado pelo looper em quatro pacientes com MSC; um paciente apresentou bloqueio atrioventricular e necessitou de marca-passo. A taxa de EA foi superior no período intradiálise em comparação ao interdiálise (p<0,001). CONCLUSÕES: neste estudo, que avaliou a monitorização cardíaca prolongada com looper implantável em candidatos a transplante renal, a taxa de ocorrência de EA foi elevada; foram preditores dos EA: a duração intervalo PR e presença de QT longo para bradiarritmias, duração intervalo QTc e insuficiência cardíaca para arritmias ventriculares e dilatação ventricular para TVNS; a taxa de mortalidade foi elevada, com importante contribuição da MSC; não houve associação entre EA e mortalidade total ou súbita; houve associação entre as bradiarritmias e a fibrilação atrial com a ocorrência de eventos não fatais; os EA foram mais frequentes no período intradiálise; o looper implantável foi eficiente na elucidação diagnóstica, com poucas complicações. / INTRODUCTION: chronic kidney disease patients undergoing dialysis have a high annual mortality rate, mainly due to cardiovascular disease. Sudden cardiac death (SCD), attributed to arrhythmic mechanisms, is considered the major cause of these high death rates. The implantable loop recorder (ILR), a modern cardiac device has the ability for long-term cardiac rhythm monitoring and diagnosing arrhythmic events (AE), which in fact may contribute to the risk stratification of this population. OBJECTIVES: this study was designed to evaluate the incidence and predictors of AE in renal transplant candidates with ILR; to determine the prognostic significance of AE in SCD and all-cause mortality, evaluate the diagnostic effectiveness of ILR and the role of dialysis. METHODS: a prospective, open, observational clinical study was conducted, including one hundred renal transplant candidates undergoing hemodialysis, at high risk for transplantation (age >=50 years, diabetes or cardiovascular disease). Between June/2009 and January/2010, patients received an ILR for detection of AE with a one-year follow-up. Mean age of the group was 59 years; 65% were men; 97% hypertensive, 70% diabetic, 34% had previous myocardial infarction and mean hemodialysis time was 53.8 months. The diagnosis of AE followed specific protocol and all fatal and non-fatal clinical events were described. The statistical analysis included: descriptive analysis of AE, an association between these events and exploratory variables by chi-square tests, Fisher exact test, Student\'s t test, Mann-Whitney test and logistic regression using stepwise selection for multivariate analysis (p<0.05). RESULTS: during mean follow-up of 425 days, 5075 AE were diagnosed by ILR in 98 patients. The rate of occurrence of EA in this patients was: bradyarrhythmias (25%), supraventricular arrhythmias (94%) and ventricular arrhythmias (79%). The most common AE were: sinus tachycardia (39%), nonsustained atrial tachycardia (27%), isolated premature ventricular beats (16%), isolated premature atrial beats (5.4%) and nonsustained ventricular tachycardia (NSVT - 5.3%). Predictors for the occurrence of AE were: duration of PR interval (p=0.0008; OR=1.05; 95%CI=1.02-1.08) and long QT (p=0.002; OR=7.28; 95%CI=2.01-26.35) for bradyarrhythmia; duration of QTc interval (p=0.022; OR=1.02; 95%CI=1.01-1.04) and presence of heart failure (p=0.034; OR=9.87; 95%CI=1.17-82.79) for ventricular arrhythmia and left ventricular dilatation (p=0.041; OR=2.83; 95%CI=1.01-7.96) for NSVT. There were 35 non-fatal clinical events, 14 renal transplantations and 18 deaths during follow-up. Regarding causes of death, 38.9% were due to sudden cardiovascular event: four were arrhythmogenic, one resulted from acute myocardial infarction and two were indeterminate. There was no association between AE and all cause or sudden mortality; bradyarrhythmias and atrial fibrillation were associated with the occurrence of non-fatal clinical events. The mechanism of death (arrhythmogenic) was elucidated by ILR in four patients with SCD; one patient had atrioventricular block and required pacemaker insertion. The rate of AE was higher in the intradyalitic period compared to interdialytic (p <0.001). CONCLUSIONS: in this study, which evaluate long-term cardiac rhythm monitoring with ILR in renal transplant candidates, the incidence of AE was high; predictors for the occurrence of AE were: duration of PR interval and presence of long QT for bradyarrhythmia, duration of QTc interval and heart failure for ventricular arrhythmia and left ventricular dilatation for NSVT; mortality rate was high and SCD made an important contribution. There was no association between AE and all-cause mortality and SCD; bradyarrhythmias and atrial fibrillation were associated with non-fatal events; the EA rate was higher at intradialytic period; the ILR was efficient in elucidating diagnoses and had few complications.
37

Eventos arrítmicos em pacientes com lúpus eritematoso sistêmico: correlações eletrocardiográficas e laboratoriais / Arrhythmic events in patients with systemic lupus erythematosus: electrocardiographic and laboratory correlations

Ricardo Alkmim Teixeira 10 June 2009 (has links)
INTRODUÇÃO: O Lúpus Eritematoso Sistêmico (LES) é uma doença inflamatória crônica que pode acometer qualquer órgão ou sistema. O acometimento do coração pode ocorrer em até 50% dos casos e não existem estudos de prevalência de eventos arrítmicos (EA) em pacientes com LES, nem de correlações laboratoriais preditoras de sua ocorrência. OBJETIVOS: Estabelecer a taxa de ocorrência de EA e identificar variáveis laboratoriais preditoras de sua ocorrência em pacientes com LES em seguimento em ambulatório de hospital terciário; estabelecer a associação entre o uso de cloroquina com a ocorrência de EA e óbitos (tipo, número e tempo de seguimento). MÉTODOS: Foi realizado um estudo clínico descritivo, observacional e aberto com pacientes em seguimento ambulatorial no Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo que foram submetidos a avaliação clínica, exames laboratoriais, ECG de repouso e Holter de 24h. A associação entre as variáveis e os EA foi avaliada por meio dos testes qui-quadrado, razão de verossimilhança, teste exato de Fisher, teste t-Student, teste não-paramétrico de Mann-Whitney, regressão logística múltipla e curva ROC. RESULTADOS: Entre agosto/2005 e agosto/2006 foram estudados 325 pacientes consecutivos, sendo 8 excluídos. A idade média foi de 40,25 anos, 91% mulheres. O tempo médio do diagnóstico de LES foi de 11,36 anos e apenas 6 pacientes apresentaram critérios para atividade do LES (escore SLEDAI). Duzentos e vinte e um pacientes estavam em uso de cloroquina. Alterações ao ECG ocorreram em 66 pacientes (20,82%): 5 bloqueios atrioventriculares de 1º grau; 4 bradicardias sinusais; 4 taquicardias sinusais e 1 supraventricular; 6 bloqueios do ramo direito (BRD); 2 bloqueios do ramo esquerdo (BRE); 45 QT prolongados. Ao Holter foram identificados 4 pacientes com pausas > 2,0 segundos; 45 com FC mínima < 50bpm; 90 com extrassístoles supraventriculares (ESV); 26 com taquiarritmias supraventriculares (FA/TA); 65 com extrassístoles ventriculares (EV). Foram registrados 7 óbitos (2,47%). Idade acima de 40 anos foi preditora da ocorrência de EA (p=0,002; OR=2,523; IC 95%= 1,389-5,583). A presença do anticorpo anticardiolipina foi preditora da ocorrência de BRD/BRE (p = 0,005; OR 3,989; IC 95% = 1,615-9,852). Títulos de C3 abaixo de 105mg% foram preditores de menor probabilidade de ocorrência de FC mínima < 50bpm (p=0,016; OR=1,018; IC 95%=1,003-1,033). Os preditores para a ocorrência de EV foram a idade (p=0,002; OR=1,051; IC95%=1,018-1,085) e a duração do QRS (p=0,005; OR=1,061; IC95%=1,018-1,106); quanto mais avançada a idade e quanto mais largo o QRS, maior a probabilidade de ocorrência de EV. Para a ocorrência de TA/FA, os preditores foram a idade (p<0,001; OR=1,100; IC95%=1,050-1,154) e o tempo de uso cloroquina (p=0,035; OR=0,921; IC95%=0,853-0,994); quanto mais avançada a idade e quanto menor o tempo de uso de cloroquina, maior a probabilidade de ocorrência de TA/FA. Pacientes com mais de 50 anos e tempo de uso de cloroquina inferior a 8 anos tiveram mais TA/FA. CONCLUSÕES: Neste estudo, que avaliou pacientes com LES em seguimento ambulatorial em hospital terciário, a taxa de ocorrência de EA foi elevada; a sua correlação com variáveis laboratoriais identificou como preditores de maior ocorrência: idade acima de 40 anos, título de C3 abaixo de 105mg% e presença de anticorpo anticardiolipina. A cloroquina demonstrou efeito protetor cardíaco sobre a evolução da doença. / INTRODUCTION: Systemic Lupus Erythematosus (SLE) is a chronic inflammatory illness that can affect any organ and system. Up to 50% of patients have their heart affected and there are no prevalence studies of arrhythmic events (AE) in SLE patients and laboratory predictors are also unknown. OBJECTIVES: To establish the rate of occurrence of AE and to identify laboratory predictors in outpatients with SLE; to establish the association between chloroquine use and the occurrence of AE and death (type, number and time of follow-up). METHODS: A descriptive, observational and opened clinical study was carried out with SLE oupatients selected from the Rheumatology clinic of São Paulo University Medical School, Brazil. They were submitted to clinical evaluation, laboratory exams, resting-ECG and 24-hour Holter monitoring. Statistics: The association between the variables and the occurrence of AE was assessed by chi-square, likelihood ratio, Fishers test, t-Student, Mann-Whitney, ROC curve and logistic regressions. RESULTS: Between august/05-august/06, 325 consecutive patients were studied. Resting-ECG abnormalities were found in 66 patients, rate of 20.82%. The average age was 40.25yo, 91% female. The average time of SLE diagnosis was of 11.36y and only 6 presented criteria for diseases activity (SLEDAI score). There were 221 patients using chloroquine. ECG disturbances found: 5 1st degree AV-block; 4 sinus bradycardia; 4 sinus tachycardia and 1 supraventricular tachycardia; 6 RBBB; 2 LBBB; 45 long QT. At Holter monitoring: 4 pauses>2.0s; 45 HR<50bpm; 90 atrial ectopies; 26 atrial tachyarrhythmia; 65 ventricular ectopies. Seven death were registered (2.47%). Age above 40yo was predictor of AE (p=0.002; OR=2.5; 95%IC=1.4-5.6). Presence of anticardiolipine antibody was predictor of QRS>120ms occurrence (p = 0.005; OR 3.989; IC 95% = 1.615-9.852). C3 level bellow 105mg% was predictor of non-occurrence of HR<50bpm (p=0.02; OR=1.02;95% IC=1.003-1.03). The predictor for ventricular ectopies (VE) occurrence were age (p=0,002; OR=1,051; IC95%=1,018-1,085) and QRS duration (p=0,005; OR=1,061; IC95%=1,018-1,106); advanced age and longer QRS predicted greater probability of VE. For supraventricular tachyarrhythmia (AT/AF) the predictors were age (p<0,001; OR=1,100; IC95%=1,050-1,154) and time of Chloroquine use (p=0,035; OR=0,921; IC95%=0,853-0,994); advanced age and short time of Chloroquine use are related to greater probability of AT/AF. Patients older than 50y and using chloroquine for less than 8y had more AT/AF. CONCLUSIONS: The rate of AE occurrence was high (20%) and the correlation with laboratory variables identified predictors of occurrence of AE: age above 40 years, C3 level below 105mg% and anticardiolipin antibody. Chloroquine demonstrated cardiac protection effect.
38

Influências do consumo de café em diferentes torras em variáveis cardiológicas de voluntários com doença coronariana crônica / Effects of two roasts of coffee consumption on cardiological parameters in volunteers with coronary artery disease

Mioto, Bruno Mahler 11 December 2015 (has links)
INTRODUÇÃO: Os efeitos do consumo de café na frequência e ritmo cardíaco, na pressão arterial e risco cardiovascular permanecem um assunto controverso. O objetivo desse estudo foi avaliar os efeitos do consumo de café filtrado nas torra escura e média na frequência cardíaca (FC), na frequência de extrassístoles, na variabilidade de frequência cardíaca (VFC), na pressão arterial, na tolerância ao exercício e em isquemia e angina em voluntários com doença arterial coronariana (DAC). MÉTODOS: Em um ensaio clínico randomizado e com crossover, comparamos o efeito do consumo de 450 a 600 ml de café nas torras escura e média em 41 voluntários com DAC, com idade média de 64,5 ± 6,7 anos, sendo que 33 eram do sexo masculino (80,5%). Após período de washout (período basal) e após cada período de quatros semanas de consumo de café (em ambas torras), os voluntários foram submetidos a teste ergométrico (TE), monitorização ambulatorial da pressão arterial (MAPA) e eletrocardiografia dinâmica (Holter). RESULTADOS: O consumo contínuo de café não exerceu nenhum efeito deletério na isquemia miocárdica desencadeada por esforço no teste ergométrico. O tempo total de exercício (deltaT Exercício) foi de 566,59 ± 192,40, 599,39 ± 205,60 e 602,22 ± 210,24 segundos (s), respectivamente para o momento basal (após washout), após consumo de café torra escura e após consumo de café torra média (média ± DP, p = 0,002). Na MAPA, as variáveis encontradas após período basal, após consumo de café torra escura e após consumo de café torra média foram, respectivamente: pressão arterial sistólica (PAS) de 110,59 ± 12,05, 111,83 ± 12,89 e 114,32 ± 11,89 mmHg (média ± DP, p = 0,065); e pressão arterial diastólica (PAD) de 64,10 ± 8,99, 64,85 ± 9,31 e 66,27 ± 9,59 mmHg (média ± DP, p = 0,143). Os valores a seguir foram obtidos através do Holter após período basal, após consumo de café torra escura e após consumo de café torra média, respectivamente: FC Média de 67,38 ± 8,44, 66,51 ± 8,11, e 67,44 ± 8,54 (média ± DP, p = 0,59); frequência de extrassístoles supraventriculares (ESV) de 21 (75), 22 (59), e 18 (85) [mediana (intervalo interquartil), p = 0,77]; frequência de extrassístoles ventriculares (EV) de 8 (426), 10 (123), e 8 (36) [mediana (intervalo interquartil), p = 0,17]; e desvio padrão de todos os intervalos RR normais (SDNN) de 129,87 ± 32,82, 134,74 ± 30,90, e 128,31 ± 28,12 (média ± DP, p = 0,16). CONCLUSÕES: Neste estudo, o consumo contínuo de café aumentou a tolerância ao exercício, não afetou de forma significativa a pressão arterial, o ritmo e a frequência cardíaca e não aumentou a frequência de extrassístoles ventriculares e supraventriculares. Com relação a presença de isquemia e/ou angina no TE, não ocorreram modificações relacionadas ao consumo de café em ambas torras / BACKGROUND: The effect of coffee on heart rate (HR), cardiac rhythm, blood pressure (BP) and cardiovascular risk has long been a controversial issue. The aim of this study was to compare the effects of dark roast (DR) and medium-dark roast (MDR) paper-filtered coffee on HR, premature complexes, heart rate variability (HRV), BP, total exercise time (deltaT Exercise) and exercise-induced angina pectoris in volunteers with coronary artery disease (CAD). METHODS: In a randomized crossover trial, we compared the effects of consuming three to four cups (150 mL) of DR and MDR coffee per day for 4 weeks in 41 volunteers with CAD, with 64.5 ± 6.7 years old, 33 men (80.5%). At baseline and after each 4-week period of drinking, the subjects were submitted to treadmill test, ambulatory blood pressure monitoring (24-h ABPM) and 24-hour Holter electrocardiograms (24-h Holter). RESULTS: The continuous coffee consumption had no deleterious effect on exercise-induced angina pectoris on treadmill test. The deltaT Exercise at baseline and after ingesting DR and MDR were 566.59 ± 192.40, 599.39 ± 205.60 and 602.22 ± 210.24 seconds, respectively (mean ± SD, p = 0.002). The analyzed parameters on 24-h ABPM at baseline and after 4 weeks of DR and MDR coffee consumption were, respectively: systolic BP of 110.59 ± 12.05, 111.83 ± 12.89 and 114.32 ± 11.89 mmHg (mean ± SD, p = 0.065); and diastolic BP of 64.10 ± 8.99, 64.85 ± 9.31 e 66.27 ± 9.59 mmHg (mean ± SD, p = 0,143). The following values were obtained on 24-h Holter at baseline and after 4 weeks of DR and MDR coffee consumption, respectively: average HRs of 67.38 ± 8.44, 66.51 ± 8.11, and 67.44 ± 8.54 (mean ± SD, p = 0.59); premature atrial complexes of 21 (75), 22 (59), and 18 (85) [median (IQR), p = 0.77]; premature ventricular complexes of 8 (426), 10 (123), and 8 (36) [median (IQR), p = 0.17]; and standard deviations of normal to normal R-R intervals (SDNNs) of 129.87 ± 32.82, 134.74 ± 30.90, and 128.31 ± 28.12 (mean ± SD, p = 0.16). CONCLUSIONS: In this study, continuous coffee consumption increased total exercise time, did not significantly affect blood pressure, HR or HRV and did not increase the frequency of premature complexes in volunteers with CAD. Furthermore, continuous coffee consumption had no deleterious effect on exercise-induced angina pectoris
39

Influências do consumo de café em diferentes torras em variáveis cardiológicas de voluntários com doença coronariana crônica / Effects of two roasts of coffee consumption on cardiological parameters in volunteers with coronary artery disease

Bruno Mahler Mioto 11 December 2015 (has links)
INTRODUÇÃO: Os efeitos do consumo de café na frequência e ritmo cardíaco, na pressão arterial e risco cardiovascular permanecem um assunto controverso. O objetivo desse estudo foi avaliar os efeitos do consumo de café filtrado nas torra escura e média na frequência cardíaca (FC), na frequência de extrassístoles, na variabilidade de frequência cardíaca (VFC), na pressão arterial, na tolerância ao exercício e em isquemia e angina em voluntários com doença arterial coronariana (DAC). MÉTODOS: Em um ensaio clínico randomizado e com crossover, comparamos o efeito do consumo de 450 a 600 ml de café nas torras escura e média em 41 voluntários com DAC, com idade média de 64,5 ± 6,7 anos, sendo que 33 eram do sexo masculino (80,5%). Após período de washout (período basal) e após cada período de quatros semanas de consumo de café (em ambas torras), os voluntários foram submetidos a teste ergométrico (TE), monitorização ambulatorial da pressão arterial (MAPA) e eletrocardiografia dinâmica (Holter). RESULTADOS: O consumo contínuo de café não exerceu nenhum efeito deletério na isquemia miocárdica desencadeada por esforço no teste ergométrico. O tempo total de exercício (deltaT Exercício) foi de 566,59 ± 192,40, 599,39 ± 205,60 e 602,22 ± 210,24 segundos (s), respectivamente para o momento basal (após washout), após consumo de café torra escura e após consumo de café torra média (média ± DP, p = 0,002). Na MAPA, as variáveis encontradas após período basal, após consumo de café torra escura e após consumo de café torra média foram, respectivamente: pressão arterial sistólica (PAS) de 110,59 ± 12,05, 111,83 ± 12,89 e 114,32 ± 11,89 mmHg (média ± DP, p = 0,065); e pressão arterial diastólica (PAD) de 64,10 ± 8,99, 64,85 ± 9,31 e 66,27 ± 9,59 mmHg (média ± DP, p = 0,143). Os valores a seguir foram obtidos através do Holter após período basal, após consumo de café torra escura e após consumo de café torra média, respectivamente: FC Média de 67,38 ± 8,44, 66,51 ± 8,11, e 67,44 ± 8,54 (média ± DP, p = 0,59); frequência de extrassístoles supraventriculares (ESV) de 21 (75), 22 (59), e 18 (85) [mediana (intervalo interquartil), p = 0,77]; frequência de extrassístoles ventriculares (EV) de 8 (426), 10 (123), e 8 (36) [mediana (intervalo interquartil), p = 0,17]; e desvio padrão de todos os intervalos RR normais (SDNN) de 129,87 ± 32,82, 134,74 ± 30,90, e 128,31 ± 28,12 (média ± DP, p = 0,16). CONCLUSÕES: Neste estudo, o consumo contínuo de café aumentou a tolerância ao exercício, não afetou de forma significativa a pressão arterial, o ritmo e a frequência cardíaca e não aumentou a frequência de extrassístoles ventriculares e supraventriculares. Com relação a presença de isquemia e/ou angina no TE, não ocorreram modificações relacionadas ao consumo de café em ambas torras / BACKGROUND: The effect of coffee on heart rate (HR), cardiac rhythm, blood pressure (BP) and cardiovascular risk has long been a controversial issue. The aim of this study was to compare the effects of dark roast (DR) and medium-dark roast (MDR) paper-filtered coffee on HR, premature complexes, heart rate variability (HRV), BP, total exercise time (deltaT Exercise) and exercise-induced angina pectoris in volunteers with coronary artery disease (CAD). METHODS: In a randomized crossover trial, we compared the effects of consuming three to four cups (150 mL) of DR and MDR coffee per day for 4 weeks in 41 volunteers with CAD, with 64.5 ± 6.7 years old, 33 men (80.5%). At baseline and after each 4-week period of drinking, the subjects were submitted to treadmill test, ambulatory blood pressure monitoring (24-h ABPM) and 24-hour Holter electrocardiograms (24-h Holter). RESULTS: The continuous coffee consumption had no deleterious effect on exercise-induced angina pectoris on treadmill test. The deltaT Exercise at baseline and after ingesting DR and MDR were 566.59 ± 192.40, 599.39 ± 205.60 and 602.22 ± 210.24 seconds, respectively (mean ± SD, p = 0.002). The analyzed parameters on 24-h ABPM at baseline and after 4 weeks of DR and MDR coffee consumption were, respectively: systolic BP of 110.59 ± 12.05, 111.83 ± 12.89 and 114.32 ± 11.89 mmHg (mean ± SD, p = 0.065); and diastolic BP of 64.10 ± 8.99, 64.85 ± 9.31 e 66.27 ± 9.59 mmHg (mean ± SD, p = 0,143). The following values were obtained on 24-h Holter at baseline and after 4 weeks of DR and MDR coffee consumption, respectively: average HRs of 67.38 ± 8.44, 66.51 ± 8.11, and 67.44 ± 8.54 (mean ± SD, p = 0.59); premature atrial complexes of 21 (75), 22 (59), and 18 (85) [median (IQR), p = 0.77]; premature ventricular complexes of 8 (426), 10 (123), and 8 (36) [median (IQR), p = 0.17]; and standard deviations of normal to normal R-R intervals (SDNNs) of 129.87 ± 32.82, 134.74 ± 30.90, and 128.31 ± 28.12 (mean ± SD, p = 0.16). CONCLUSIONS: In this study, continuous coffee consumption increased total exercise time, did not significantly affect blood pressure, HR or HRV and did not increase the frequency of premature complexes in volunteers with CAD. Furthermore, continuous coffee consumption had no deleterious effect on exercise-induced angina pectoris
40

Caracterização do perfil da micro-alternância da onda T na cardiomiopatia hipertrófica / Characterization of the profile of microvolt T-wave alternans in hypertrophic cardiomyopathy

Antunes, Murillo de Oliveira 19 March 2014 (has links)
Introdução: A cardiomiopatia hipertrófica (CMH) é definida, como a hipertrofia miocárdica ocorrida na ausência de doença cardíaca ou sistêmica, sendo a mais prevalente das cardiopatias de transmissão genética e a principal causa de morte súbita em jovens e atletas. A única opção de tratamento para prevenção dessa complicação é a indicação do cardiodesfibrilador implantável (CDI). Alguns marcadores de risco foram identificados, como: pacientes que sobreviveram à parada cardíaca por fibrilação ventricular, episódio de taquicardia ventricular sustentada; história familiar precoce de MSC; síncope inexplicada; espessura septal >= 30 mm; taquicardia ventricular não sustentada (TVNS) no Holter; queda da pressão sistólica (PAS) > 20 mmHg ou aumento < 20 mmHg no esforço. Entretanto, a sensibilidade e especificidade desses critérios são limitadas, tornando necessário o conhecimento de novos métodos diagnósticos com capacidade de predizer MSC. A micro-alternância da onda T (MAOT) é utilizada como ferramenta diagnóstica na estratificação de pacientes com riscos de desenvolver arritmias ventriculares malignas e MSC auxiliando na indicação do CDI. Na CMH há poucos estudos realizados com objetivos e resultados diferentes e, atualmente, uma nova metodologia na realização desses exames foi desenvolvida, não sendo testada nesta população. Os objetivos do presente estudo foram: caracterizar os valores da MAOT pela metodologia Média Móvel Modificada (MMM) e avaliar a associação de seus resultados com os fatores de risco clínicos para MSC. Metodologia: Foram selecionados 132 pacientes com CMH que foram divididos em dois grupos: 1) Alto Risco, 67 pacientes, que apresentavam, pelo menos, um fator de risco para morte súbita cardíaca (história familiar de morte súbita; síncope inexplicada; espessura septal do miocárdio >=30 mm; taquicardia ventricular não sustentada; queda da pressão sistólica no teste de esforço) e 2) Baixo Risco, 65 pacientes, sem fatores de risco. A idade média foi de 37 ± 11,3 anos, sendo 63% do sexo masculino. A média da espessura de septo interventricular foi 23,9 ± 6,2 mm, da fração de ejeção 72 ± 8,1% e 26% apresentavam forma obstrutiva da doença. A MAOT foi avaliada pelo teste ergométrico com protocolo Naughton modificado, com dois fatores de atualização (FaT) 1/8 e 1/32, de forma quantitativa e qualitativa (positivo e negativo) e com três formas de análises: considerando todas as derivações do eletrocardiograma (plano periférico, frontal e ortogonal); desconsiderando os resultados do plano periférico e desconsiderando as derivações ortogonais. Resultados: A aferição da MAOT com FaT 1/8 apresentou maior sensibilidade em comparação com FaT 1/32 (FaT 1/8 MAOTméd. = 69,2 uV a 78,2 uV vs FaT 1/32 MAOTméd. = 33,2 uV a 38,7 uV, p < 0,01), resultando nas análises quantitativas de valores maiores da micro-alternância (MAOTmáx. - FaT 1/8 = 528 uV vs 124 uV = FaT 1/32, p < 0,01) e na análise qualitativa maior número de exames positivos (MAOT positiva - FaT 1/8 = 57,5% vs 19,0% = FaT 1/32). Os pacientes do grupo Alto risco apresentavam maiores valores de MAOT (Alto Risco MAOT média = 101,4 uV vs 54,3 uV Baixo Risco, p < 0,001) e 84% apresentavam exame positivo (56/67). A MAOT mostrou associação significativa com os fatores de risco para MSC: espessura septal >= 30 mm (p < 0,001), TVNS no Holter 24 h (p = 0,001), história familiar de MSC (p = 0,006) e queda da pressão arterial no esforço (p = 0,02). No rastreamento de pacientes de Alto risco, com ponto de corte de 53 uV o teste apresentou sensibilidade e especificidade de 84% e 71%, com acurácia de 0,77 (IC de 95%: 0,69 a 0,86). Conclusões: Os melhores resultados da MAOT pela metodologia Média Móvel Modificada foram encontrados analisando todas as derivações eletrocardiográficas (plano periférico, horizontal e derivações ortogonais), realizados de forma quantitativa, com Fator de Atualização 1/8 e ponto de corte para positividade 53 uV. A MAOT demonstrou associação significativa com a maioria dos fatores de risco clínicos apresentando boa acurácia no rastreamento dos pacientes de Alto Risco para MSC / Introduction: Hypertrophic cardiomyopathy (HCM) is defined as the myocardial hypertrophy in the absence of cardiac or systemic disease, being the most common genetic transmission cardiopathy and responsible for sudden cardiac death (SCD) in young adults and athletes. The first-line treatment option for prevention of SCD is the implantable cardioverter-defibrillator (ICD). Some clinical factors have been identified as high risk for the occurrence of SCD: history of cardiac resuscitation for ventricular fibrillation, episode of sustained ventricular tachycardia, family history of premature SCD, unexplained syncope, ventricular septal thickness >= 30 mm; nonsustained ventricular tachycardia (NSVT) in Holter and inadequate response of blood pressure to exercise: decrease in systolic blood pressure (SBP) > 20 mmHg or increase < 20 mmHg during effort. These criteria, however, are limited in sensitivity and specificity and new diagnostic methods have been required. The microvolt T-wave alternans (MTWA) is used as a diagnostic tool to identify high-risk patients predisposed to malignant ventricular arrhythmias and SCD. Therefore, MTWA may be helpful to indicate ICD. There are no reports in the literature concerning the use of MTWA in HCM. This research aims to evaluate the values of MTWA by modified moving average (MMA) method and the association with clinical factors for SCD. Methods: We enrolled 132 patients with HCM that were divided into two groups: 1) High Risk (HR) group, 67 patients, that had at least one risk factor for sudden cardiac death (family history of SCD; unexplained syncope; ventricular septal thickness >= 30 mm; nonsustained ventricular tachycardia; inadequate response of blood pressure to exercise) and 2) Low Risk (LR) group, 65 patients, without risk factors. The most participants were male (63%) and their mean age was 37 (± 11.3) years. All individuals were evaluated by echocardiography: 23,9 ± 6,2 mm interventricular septal thickness; 72 ± 8.1% ejection fraction and 26% left ventricular outflow gradient of more than 30 mmHg. Patients performed exercise stress testing with modified Naughton Protocol. In the present study, MTWA was assessed with the MMA method, updating factor (UF) 1/8 and 1/32, quantitative and qualitative way (positive and negative). In addition, the values of the MTWA were evaluated in three ways: all the leads of electrocardiogram; disregarding the leads of peripheral plane; disregarding the orthogonal leads. Results: The analysis of MTWA with UF 1/8 showed greater sensitivity compared with UF 1/32 (Mean MTWA, UF 1/8 = 69.2 uV to 78.2 uV vs UF 1/32 = 33.2 uV to 38.7 uV, p < 0.01). Like this, in quantitative and qualitative (positive and negative) analysis of MTWA, the values were larger in the group of UF 1/8 (UF1/8 = 528 uV vs UF 1/32 = 124 uV, p < 0.01/ Positive MTWA, UF 1/8 = 57.5% vs UF 1/32 = 19.0%, p < 0.01). The patients of High Risk group presents higher values of MTWA (HR = 101.4 uV vs LR = 54.3 uV, p < 0.001) and 84% had the positive test. The MTWA was significantly associated with risk factors for SCD: ventricular septal thickness >= 30 mm (p < 0.001), NSVT (p = 0.001), family history of SCD (p = 0.006), inadequate response of blood pressure to exercise (p = 0.02). In the analysis of high risk group, using a cutoff value of 53 uV, we observed a sensitivity of 84%, specificity of 71% and accuracy of 0.77 (95% confidence interval: 0.69 to 0.86). Conclusions: The best results of MTWA by MMA method were found by analyzing all lead ECG (frontal and peripheral plane and orthogonal leads), using UF 1/8, quantitative analysis and cut-off value 53 uV. The MTWA was significantly associated with clinical risk factors, showing a good accuracy, and can be used to effectively select high-risk patients for SCD

Page generated in 0.1703 seconds